TY - CONF A1 - Schneider-Gloetzl, J. T1 - Geotechnical Monitoring of Construction Activities by Distributed Fibre Optic Sensors Embedded in Geotextiles T2 - 5th European Workshop on Structural Health Monitoring CY - Sorrento, Italy DA - 2010-06-29 PY - 2010 AN - OPUS4-22087 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Martínez, N.A. A1 - Schneider, Rudolf A1 - Messina, G.A. A1 - Raba, J. T1 - Modified paramagnetic beads in a microfluidic system for the determination of ethinylestradiol (EE2) in river water samples N2 - In this work, we have developed and characterized a novel microfluidic immunoassay methodology for rapid and sensitive quantification of ethinylestradiol (EE2) in river water samples. The detection of EE2 was carried out using a competitive direct immunoassay method based on the use of anti-EE2 polyclonal antibodies immobilized on magnetic microspheres 3-aminopropyl-modified manipulated for an external removable magnet. The EE2 present in the water sample was allowed to compete with EE2-horseradish peroxidase (HPR) conjugated for the immobilized anti-EE2 antibody. The HPR, in the presence of hydrogen peroxide (H2O2) catalyzes the oxidation of catechol (Q) whose back electrochemical reduction was detected on gold electrode at 0.0 V. The response current obtained from the product of enzymatic reaction is inversely proportional to the amount of EE2 in the water sample. The electrochemical detection can be done within 1 min and total assay time was 30 min. The calculated detection limits for electrochemical detection and the ELISA procedure are 0.09 and 0.32 ng L-1 respectively and the intra- and inter-assay coefficients of variation were below 5.8%. Our electrochemical immunosensor showed higher sensitivity and lower time consumed than the standard spectrophotometric detection ELISA method, which shows the potential for assessment of EE2 in river water samples. KW - Enzyme immunoassays KW - Ethinylestradiol KW - Paramagnetic beads KW - Horseradish peroxidase KW - Microfluidic KW - Flow injection analysis PY - 2010 DO - https://doi.org/10.1016/j.bios.2009.10.031 SN - 0956-5663 SN - 1873-4235 VL - 25 IS - 6 SP - 1376 EP - 1381 PB - Elsevier CY - Barking, Essex, UK AN - OPUS4-22188 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Klaffke, Dieter A1 - Schneider, Thomas A1 - Brand, J. A1 - Wittorf, R. T1 - Tribologisches Verhalten von DLC-Schichten in wässrigen Salzlösungen T2 - GfT-Jahrestagung Tribologie CY - Göttingen, Deutschland DA - 2005-09-26 KW - DLC-Schichten KW - Salzwasser KW - Korrosion KW - Schwingungsverschleiß PY - 2005 SN - 3-00-017102-9 SP - 34/1 EP - 34/10 PB - GfT CY - Moers AN - OPUS4-11027 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Matthias A1 - Jann, Oliver A1 - Kemski, J. A1 - Klingel, R. A1 - Schneider, Uwe A1 - Krocker, Christian T1 - Investigations on radon exhalation of different building materials N2 - The inhalation of 222Rn (radon) is one of the most important reasons for lung cancer, after smoking. Usually, the geological subsoil and the building ground are the dominant sources for enhanced indoor radon levels. Additionally, building materials can increase indoor radon concentrations when these materials contain higher contents of 226Ra (radium), especially in combination with low air exchange rates. For a realistic estimation of indoor radon concentrations, it is helpful to carry out measurements of radon exhalation rates from relevant materials using emission test chambers. In Germany, it is aspired to limit the total indoor radon concentration to 100 Bq/m3, whereby building materials should contribute at most 20 Bq/m3. Within a project financed by the German Institute for Construction Technology (DIBt), a practical oriented measurement procedure of the radon exhalation of building materials in accordance to ISO 16000-9 was developed to have a means for the assessment of these materials with respect to their indoor use. Test chambers with different volumes were used. The tested materials were mainly used for wall constructions (e.g., bricks, light-weight concrete) and have known specific radium activities and radon exhalation rates. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Radon exhalation KW - Building material KW - Emission test chamber KW - Indoor air PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-24155 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Glötzl, R. A1 - Schneider Glötzl, J. A1 - Wosniok, Aleksander A1 - Krebber, Katerina A1 - Krywult, L. ED - Wintera, J. ED - Kosik, A. ED - Wity, A. T1 - Optical distributed sensing systems and possible applications in geotechnical measuring N2 - In comparison with traditional measuring Systems (pressure cells, piezometers and inclinometers which produce only point measurements) fibre optic sensors are well suited for spatiallydistributed monitoring purposes. The very tiny optical fibres of a diameter of less then 1 mm can operate as sensors in strong electromagnetic fields, under “harsh” explosive and Chemical environments and under ionizing radiation. T2 - XIV Dam monitoring international conference 'safetyof dams - new challenges' ('Bezpieczenstwo zapór - nowe wyzwania') CY - Walbrzych, Poland DA - 13.06.2011 KW - Fibre optic sensor KW - Spatial distributed sensor KW - Polymer optical fibre (POF) KW - Glass optical fibre (GOF) KW - POF OTDR KW - Brillouin sensor KW - BOTDA KW - BOFDA KW - Fibre Bragg grating (FBG) KW - Geosynthetics KW - Geotxtiles KW - Technical textiles PY - 2011 SN - 978-83-61102-53-3 N1 - Serientitel: Monografie - Instytutu Meteorologii i Gospodarki Wodnej – Series title: Monografie - Instytutu Meteorologii i Gospodarki Wodnej IS - Chapter 6 SP - 173 EP - 180 AN - OPUS4-24066 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nöther, N. A1 - Krebber, Katerina A1 - Schneider-Glötzl, J. T1 - An all-digital implementation of the Brillouin optical frequency domain analysis for long-range distributed strain and temperature monitoring N2 - For long-range measurements in geotechnical and industrial applications, distributed optical fiber sensors have become a tool of increasing importance throughout the past decade. Classic deformation monitoring (performed by strain gauges etc.) and temperature monitoring (Pt100 and alike) deliver data from fixed, single spots of a structure; quasidistributed measurements (fiber bragg gratings) provide a Chain of discrete measurement points along a limited sensing length. In contrast, an opticai fiber connected to a device for distributed strain and temperature sensing (DTSS) will provide a continuous profile of strain and temperature - spatially resolved down to less than 1 m - over a ränge of several tens of kilometers. In DTSS measurements, the nonlinear opticai effect of stimulated Brillouin Scattering (SBS) is employed: two light waves with a stable, tunable frequency offset are injected into opposite ends of the sensing fiber, where they will form a beat pattem, at which parts of the light will be scattered. By matching the frequency offset of the light waves to the propagation of acoustic fluctuation in the opticai fiber, a power transfer from one light wave to the other can be measured; since the acoustic propagation directly shifts with train and temperature of the fiber, these two quantities can be measured by tuning the light waves’ frequency offset. T2 - 8th International symposium on field measurements in geomechanics - FMGM 2011 CY - Berlin, Germany DA - 12.09.2011 PY - 2011 SP - 1 EP - 6 AN - OPUS4-24664 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst A1 - Amir, J. M. A1 - Schneider, N. T1 - New possibilities for quality assurance of diaphragm wall joints N2 - Diaphragm walls are used to provide a stable and watertight confinement for the construction of tunnels, Underground railway stations, deep basements and other structures requiring deep excavations. Water seepage and soil loss through the joints have occurred on several occasions, causing extensive damage. This may have been due to uncontrolled concrete flow between the joints, unexpected geologic conditions or just poor workmanship. Different ways of quality assurance are applied on construction sites. Most of them rely on recording Parameters of the construction equipment and conventional concrete quality control. In the frame of the EUREKA/ZIM project DiWaQ we have looked at several ways to perform non-destructive Quality control. Some methods are to be applied after excavation before concreting (phase 1); others after the wall is completed (phase 2). For phase 1 we have used two different principles for checking the shape of the excavation, especially the joint to existing panels. A mechanical device which can be adapted to the excavating Equipment was developed; field tested and validated on test and construction sites. It is described in detail in another paper in the same volume. A sonar-based device with a 10 mm resolution has shown good performance in the lab, but is still under development. For phase 2 different temperature sensors have been lowered into access holes to monitor the hydration heat developed during concrete curing. The same tubes can also be used to perform electromagnetic and ultrasonic crosshole measurements across or along joints to detect flaws. Especially the ultrasonic method has shown promising results on Validation specimen at the BAM test site at Horstwalde, but limitations as well. Success substantially depended on the joint type, flaw size and distance of the sensors to the joint. T2 - International conference on piling & deep foundations CY - Stockholm, Sweden DA - 21.05.2014 KW - Diaphragm walls KW - Joints KW - Integrity KW - Crosshole sonic logging KW - Sonar PY - 2014 UR - http://www.piletest.com/papers/Niederleithinger_et_al_2014_Stockholm_2014.pdf SP - 911 EP - 918 AN - OPUS4-31201 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Anker, Andy S. A1 - Aspuru-Guzik, Alán A1 - Ben Mahmoud, Chiheb A1 - Bennett, Sophie A1 - Briling, Ksenia R. A1 - Changiarath, Arya A1 - Chong, Sanggyu A1 - Collins, Christopher M. A1 - Cooper, Andrew I. A1 - Crusius, Daniel A1 - Darmawan, Kevion K. A1 - Das, Basita A1 - David, Nicholas A1 - Day, Graeme M. A1 - Deringer, Volker L. A1 - Duarte, Fernanda A1 - Eardley-Brunt, Annabel A1 - Evans, Matthew L. A1 - Evans, Rob A1 - Fairlamb, Ian A1 - Franklin, Barnabas A. A1 - Frey, Jeremy A1 - Ganose, Alex M. A1 - Goulding, Mark A1 - Hafizi, Roohollah A1 - Hakkennes, Matthijs A1 - Hickey, Niamh A1 - James, Gillian A1 - Jelfs, Kim E. A1 - Kalikadien, Adarsh V. A1 - Kapil, Venkat A1 - Koczor-Benda, Zsuzsanna A1 - Krammer, Ferdinand A1 - Kulik, Heather J. A1 - Kumar, Vishank A1 - Kuttner, Christian A1 - Lam, Erwin A1 - Lou, Yuchen A1 - Mante, Eltjo A1 - Martin, Jennie A1 - Mroz, Austin M. A1 - Nematiaram, Tahereh A1 - Pare, Charles W. P. A1 - Patra, Sarbani A1 - Proudfoot, James A1 - Ruscic, Branko A1 - Ryder, Matthew R. A1 - Sakaushi, Ken A1 - Saßmannshausen, Jörg A1 - Savoie, Brett M. A1 - Schneider, Nadine A1 - Schwaller, Philippe A1 - Skjelstad, Bastian Bjerkem A1 - Sun, Wenhao A1 - Szczypiński, Filip T. A1 - Torrisi, Steven A1 - Ueltzen, Katharina A1 - Vishnoi, Shubham A1 - Walsh, Aron A1 - Wang, Xinwei A1 - Wilson, Chloe A1 - Wu, Ruiqi A1 - Zeitler, Jakob T1 - Discovering structure–property correlations: General discussion N2 - This article is a discussion of the paper "Web-BO: Towards increased accessibility of Bayesian optimisation (BO) for chemistry" by Austin M. Mroz, Piotr N. Toka, Ehecatl Antonio del Río Chanona and Kim E. Jelfs (Faraday discussions, 2025, 256, 221-234). KW - Materials design KW - Machine learning KW - Automation KW - Materials discovery PY - 2025 DO - https://doi.org/10.1039/d4fd90062f SN - 1359-6640 SN - 1364-5498 VL - 256 IS - Themed collection: Data-driven discovery in the chemical sciences SP - 373 EP - 412 PB - Royal Society of Chemistry (RSC) CY - Cambridge AN - OPUS4-62208 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Massiot, D. A1 - Müller, D. A1 - Hübert, Thomas A1 - Schneider, M. A1 - Kentgens, A. A1 - Coté, B. A1 - Coutures, J. A1 - Gessner, W. T1 - Double rotation and magic-angle spinning nuclear magnetic resonance study of 27Al: reexamination of the aluminium borate 9Al2O3 · 2B2O3 N2 - 27Al nuclear magnetic resonance spectra of polycrystalline aluminium borate 9Al2O3 · 2B2O3 have been measured in double rotation at 11.7 and 7.0 T and high-speed magic-angle spinning at 7.0, 9.4, 11.7, 14.1 and 17.6 T. Spinning sidebands from the satellite transitions were observed at 7.0 and 14.1 T. Each of the four structural aluminium sites [Al(IV), Al(V)(1), Al(V)(2) and Al(VI)] are observed, characterised and assigned in the spectra. The obtained parameter set gives a fully consistent interpretation in agreement with the crystal structure of the compound. KW - Aluminium KW - Kernresonanz, magnetisch KW - Winkel, magisch KW - Doppelrotation PY - 1995 DO - https://doi.org/10.1016/0926-2040(95)00021-H SN - 0926-2040 SN - 1527-3326 VL - 5 IS - 2 SP - 175 EP - 180 PB - Academ. Press CY - Orlando, Fla. AN - OPUS4-639 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Jann, Oliver A1 - Köppke, J. A1 - Lehmann, R. A1 - Schneider, Uwe T1 - Messungen der Radonexhalation aus Baustoffen unter Modellklimabedingungen PY - 2003 SN - 0949-8036 SN - 0039-0771 SN - 1436-4891 VL - 63 IS - 1/2 SP - 49 EP - 52 PB - Springer-VDI-Verl. CY - Düsseldorf AN - OPUS4-2279 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Jann, Oliver A1 - Richter, Matthias A1 - Kemski, J. A1 - Klingel, R. A1 - Schneider, Uwe A1 - Krocker, Christian T1 - Entwicklung einer praxisnahen Prüfmethode zur Bestimmung der Radon-Exhalation aus Bauprodukten KW - Radon KW - Baumaterialien KW - Emissionsprüfkammer KW - Prüfmethode PY - 2012 SN - 978-3-8167-8723-5 VL - T 3277 SP - 1 EP - 74 PB - Fraunhofer IRB Verl. CY - Stuttgart AN - OPUS4-26572 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Richter, Matthias A1 - Jann, Oliver A1 - Kemski, J. A1 - Schneider, Uwe A1 - Krocker, Christian A1 - Hoffmann, B. T1 - Determination of radon exhalation from construction materials using VOC emission test chambers N2 - The inhalation of 222Rn (radon) decay products is one of the most important reasons for lung cancer after smoking. Stony building materials are an important source of indoor radon. This article describes the determination of the exhalation rate of stony construction materials by the use of commercially available measuring devices in combination with VOC emission test chambers. Five materials – two types of clay brick, clinker brick, light-weight concrete brick, and honeycomb brick – generally used for wall constructions were used for the experiments. Their contribution to real room concentrations was estimated by applying room model parameters given in ISO 16000-9, RP 112, and AgBB. This knowledge can be relevant, if for instance indoor radon concentration is limited by law. The test set-up used here is well suited for application in test laboratories dealing with VOC emission testing. KW - Radon exhalation KW - Radon measurement KW - Building material KW - Emission test chamber KW - Indoor air quality KW - Real room radon concentrations PY - 2013 DO - https://doi.org/10.1111/ina.12031 SN - 0905-6947 SN - 1600-0668 VL - 23 IS - 5 SP - 397 EP - 405 PB - Danish Techn. Pr. CY - Copenhagen AN - OPUS4-29408 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Martínez, N.A. A1 - Pereira, S.V. A1 - Bertolino, F.A. A1 - Schneider, Rudolf A1 - Messina, G.A. A1 - Raba, J. T1 - Electrochemical detection of a powerful estrogenic endocrine disruptor: ethylestradiol in water samples through bioseparation procedure N2 - The synthetic estrogen ethinylestradiol (EE2) is an active component of oral contraceptives (OCs), considered as an endocrine disrupting compound (EDC). It is excreted from humans and released via sewage treatment plant effluents into aquatic environments. EDCs are any environmental pollutant chemical that, once incorporated into an organism, affects the hormonal balance of various species including humans. Its presence in the environment is becoming of great importance in water quality. This paper describes the development of an accurate, sensitive and selective method for capture, preconcentration and determination of EE2 present in water samples using: magnetic particles (MPs) as bioaffinity support for the capture and preconcentration of EE2 and a glassy carbon electrode modified with multi-walled carbon nanotubes (MWCNTs/GCE) as detection system. The capture procedure was based on the principle of immunoaffinity, the EE2 being extracted from the sample using the anti-EE2 antibodies (anti-EE2 Ab) which were previously immobilized on MPs. Subsequently the analyte desorption was done employing a sulfuric acid solution and the determination of the EE2 in the pre-concentrated solution was carried out by square wave voltammetry (SWV). This method can be used to determine EE2 in the range of 0.035–70 ng L-1 with a detection limit (LOD) of 0.01 ng L-1 and R.S.D. < 4.20%. The proposed method has been successfully applied to the determination of EE2 in water samples and it has promising analytical applications for the direct determination of EE2 at trace levels. KW - Magnetic particles KW - Bioseparation KW - Ethinylestradiol KW - Electrochemistry KW - Immunoassay KW - Elektrochemischer Sensor KW - Endokrine Disruptoren KW - Hormone KW - EE2 KW - Östrogene PY - 2012 DO - https://doi.org/10.1016/j.aca.2012.02.033 SN - 0003-2670 SN - 1873-4324 SN - 0378-4304 VL - 723 SP - 27 EP - 32 PB - Elsevier CY - Amsterdam AN - OPUS4-25656 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carvalho, J.J.D. A1 - Bahlmann, Arnold A1 - Schneider, Rudolf T1 - ELISA goes Berlin - Bestimmung von Carbamazepin, Cetrizin und Coffein in Berliner Gewässern N2 - Sensitive und selektive Immunoassays unterstützen Untersuchungen im Vollzug der EU Wasserrahmenrichtlinie. Sie erlauben, eine hohe Anzahl von Proben ohne Anreicherungsschritte zu untersuchen und ermöglichen daher den Aufbau eines zeitlich und räumlich engmaschigen Messnetzes. Mit Hilfe von ELISA (enzymelinked immunosorbent assay) wurde ein Gewässerscreening in Berlin durchgeführt. KW - ELISA KW - Koffein KW - Immunoassay KW - Oberflächenwasser KW - Wasseranalytik PY - 2012 SN - 0016-3538 VL - 4 SP - 278 EP - 281 PB - GIT-Verlag CY - Darmstadt AN - OPUS4-27518 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schneider, Rudolf J. T1 - Evaluating the Normalization Potential of Anthropogenic Markers in Wastewater: Monitoring Influents of German Treatment Plants by ELISA N2 - Wastewater-based epidemiology (WBE) has emerged as a vital tool for pandemic preparedness, offering early warning capabilities and supporting public health interventions. In Germany, combined sewer systems are prevalent, leading to fluctuations in wastewater volume and com-position due to rainwater inflow, especially through street drains. This variability complicates the quantitative measurement of pathogens and pollutants in wastewater. While human excretion provides constant inputs, these parameters are often non-specific, lost, or degraded during transport. Pharmaceuticals—such as carbamazepine, diclofenac, and clarithromycin—as well as commonly consumed substances like caffeine, exhibit sufficiently high concentrations and good chemical stability in wastewater and are not subject to seasonal fluctuations. Antibody-based methods, particularly Enzyme-Linked Immunosorbent Assays (ELISA), offer a cost-effective alternative to complex chromatographic techniques for monitoring anthropogenic markers. They demonstrate superior normalization quality compared to the frequently used quantitative PCR-based marker Pepper mild mottle virus (PMMoV). T2 - 6th International Conference on Risk Assessment of Pharmaceuticals in the Environment - ICRAPHE CY - Aveiro, Portugal DA - 20.10.2025 KW - Carbamazepin KW - Koffein KW - Spurenstoffe KW - Anthropogener Marker Immunoassay PY - 2025 AN - OPUS4-64432 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pauli, J. A1 - Güttler, Arne A1 - Schneider, T. A1 - Würth, Christian A1 - Resch-Genger, Ute T1 - Fluorescence Quantum Yield Standards for the UV/Visible/NIR: Development, Traceable Characterization, and Certification N2 - The rational design of next generation molecular and nanoscale reporters and the comparison of different emitter classes require the determination of the fluorometric key performance parameter fluorescence quantum yield (Φf), i.e., the number of emitted photons per number of absorbed photons. Main prerequisites for reliable Φf measurements, which are for transparent luminophore solutions commonly done relative to a reference, i.e., a fluorescence quantum yield standard of known Φf, are reliable and validated instrument calibration procedures to consider wavelength-, polarization-, and time-dependent instrument specific signal contributions, and sufficiently well characterized fluorescence quantum yield standards. As the standard’s Φf value directly contributes to the calculation of the sample’s Φf, its accuracy presents one of the main sources of uncertainty of relative Φf measurements. To close this gap, we developed a first set of 12 fluorescence quantum yield standards, which absorb and emit in the wavelength region of 330−1000 nm and absolutely determined their Φf values with two independently calibrated integrating sphere setups. Criteria for standard selection and the configuration of these novel fluorescence reference materials are given, and the certification procedure is presented including homogeneity and stability studies and the calculation of complete uncertainty budgets for the certified Φf values. The ultimate goal is to provide the community of fluorescence users with available reference materials as a basis for an improved comparability and reliability of quantum yield data since the measurement of this spectroscopic key property is an essential part of the characterization of any new emitter. KW - Optical spectroscopy KW - Traceability KW - Reference product KW - Dye KW - Fluorescence KW - Quantum yield KW - Reference material KW - Reference data KW - Certification KW - Quality assurance PY - 2023 DO - https://doi.org/10.1021/acs.analchem.2c05530 VL - 95 SP - 5671 EP - 5677 PB - American Chemical Society AN - OPUS4-58151 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schneider, Joachim A1 - Adamczyk, Burkart A1 - Ebert, D. A1 - Ehrenberg, A. A1 - Schraut, Katharina A1 - Gerlach, J. A1 - Wendt, K. A1 - Algermissen, D. A1 - Adam, Christian ED - Rogge, Andreas ED - Meng, Birgit T1 - Erzeugung von Bindemitteln aus Stahlwerksschlacken N2 - Die geplante Transformation der Stahlindustrie innerhalb der nächsten 20 Jahre hat aufgrund des mit ihr verbundenen Auslaufens der Hüttensanderzeugung Konsequenzen für die Zementindustrie, deren Abmilderung Gegenstand der Forschungsprojekte SlagCEM und DRI-EOS ist. Ersteres untersucht die Rückgewinnung von Eisen aus LD-Konverter-Schlacke bei gleichzeitiger Herstellung eines mineralischen Produktes mit zementä- ren Eigenschaften. Zweiteres befasst sich mit der Generierung eines Hüttensandersatzes aus Lichtbogen- ofenschlacke mit Rückgewinnung von Schwermetallen sowie deren Umwelteffekt bei Verbleib in der Schlacke. T2 - 11. Jahrestagung des DAfStb mit 63. Forschungskolloquium der BAM Green Intelligent Building CY - Berlin, Germany DA - 16.10.2024 KW - Bindemittel KW - Stahlwerksschlacke PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-613127 SN - 978-3-9818564-7-7 SP - 78 EP - 89 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-61312 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Laquai, René A1 - Müller, Bernd R. A1 - Schneider, J. A1 - Kupsch, Andreas A1 - Bruno, Giovanni T1 - Using SXRR to Probe the Nature of Discontinuities in SLM Additive Manufactured Inconel 718 Specimens N2 - The utilization of additive manufacturing (AM) to fabricate robust structural components relies on understanding the nature of internal anomalies or discontinuities, which can compromise the structural integrity. While some discontinuities in AM microstructures stem from similar mechanisms as observed in more traditional processes such as casting, others are unique to the AM process. Discontinuities in AM are challenging to detect, due to their submicron size and orientation dependency. Toward the goal of improving structural integrity, minimizing discontinuities in an AM build requires an understanding of the mechanisms of formation to mitigate their occurrence. This study utilizes various techniques to evaluate the shape, size, nature and distribution of discontinuities in AM Inconel 718, in a non-hot isostatic pressed (HIPed) as-built, non-HIPed and direct age, and HIPed with two step age samples. Non-destructive synchrotron radiation refraction and transmission radiography (SXRR) provides additional information beyond that obtained with destructive optical microscopy. SXRR was able to distinguish between voids, cracks and lack of melt in, due to its sensitivity to the orientation of the discontinuity. KW - Additive manufacturing KW - X-ray refraction radiography KW - INCONEL 718 KW - Selective laser melting PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-509836 DO - https://doi.org/10.1007/s11661-020-05847-5 SN - 1543-1940 VL - 51 IS - 8 SP - 4146 EP - 4157 PB - Springer AN - OPUS4-50983 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Riedel, Soraya A1 - Hülagü, Deniz A1 - Bennet, Francesca A1 - Carl, Peter A1 - Flemig, Sabine A1 - Schmid, Thomas A1 - Schenk, J. A. A1 - Hodoroaba, Vasile-Dan A1 - Schneider, Rudolf T1 - Electrochemical Immunomagnetic Ochratoxin A Sensing: Steps Forward in the Application of 3,3’,5,5’- Tetramethylbenzidine in Amperometric Assays N2 - Electrochemical methods offer great promise in meeting the demand for user-friendly on-site devices for Monitoring important parameters. The food industry often runs own lab procedures, for example, for mycotoxin analysis, but it is a major goal to simplify analysis, linking analytical methods with smart technologies. Enzyme-linked immunosorbent assays, with photometric detection of 3,3’,5,5’-tetramethylbenzidine (TMB),form a good basis for sensitive detection. To provide a straightforward approach for the miniaturization of the detectionstep, we have studied the pitfalls of the electrochemical TMB detection. By cyclic voltammetry it was found that the TMB electrochemistry is strongly dependent on the pH and the electrode material. A stable electrode response to TMB could be achieved at pH 1 on gold electrodes. We created a smartphonebased, electrochemical, immunomagnetic assay for the detection of ochratoxin A in real samples, providing a solid basis forsensing of further analytes. KW - Ochratoxin A KW - Amperometry KW - Cyclic voltammetry KW - Electrochemistry KW - Immunoassay PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-530421 DO - https://doi.org/10.1002/celc.202100446 N1 - Geburtsname von Riedel, Soraya: Höfs, S. - Birth name of Riedel, Soraya: Höfs, S. VL - 8 IS - 13 SP - 2597 EP - 2606 AN - OPUS4-53042 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carl, Peter A1 - Sarma, Dominik A1 - Gregório, Bruno J. R. A1 - Hoffmann, Kristin A1 - Lehmann, Andreas A1 - Rurack, Knut A1 - Schneider, Rudolf T1 - Wash-Free Multiplexed Mix-and-Read Suspension Array Fluorescence Immunoassay for Anthropogenic Markers in Wastewater N2 - Pharmaceuticals, certain food ingredients, and mammalian endogenous metabolic products in wastewater are mostly of human origin. They are anthropogenic markers. Proper knowledge of their levels in wastewater helps to track sources of pollutants in natural waters and allows for calculation of removal efficiencies in wastewater Treatment plants. Here, we describe the development and application of an indirect competitive, multiplexing suspension Array fluorescence immunoassay (SAFIA) for the detection of carbamazepine (CBZ), diclofenac (DCF), caffeine (CAF), and isolithocholic acid (ILA) in wastewater, covering those classes of anthropogenic markers. The assay consists of haptens covalently conjugated to fluorescence-encoded polystyrene core/silica shell microparticles to create a site for competitive binding of the antibodies (Abs). Bound Abs are then stained with fluorophore-labeled Abs. Encoding and signaling fluorescence of the particles are determined by an automated flow cytometer. For compatibility of the immunoassay with the 96-well microtiter plate format, a stop reagent, containing formaldehyde, is used. This enables a wash-free procedure while decreasing time-to-result. Detection limits of 140 ± 40 ng/L for CBZ, 180 ± 110 ng/L for CAF, 4 ± 3 ng/L for DCF, and 310 ± 70 ng/L for ILA are achieved, which meet the sensitivity criteria of wastewater analysis. We demonstrate the applicability of SAFIA to real wastewater samples from three different wastewater Treatment plants, finding the results in good agreement with LC-MS/MS. Moreover, the accuracy in general exceeded that from classical ELISAs. We therefore propose SAFIA as a quick and reliable approach for wastewater analysis meeting the requirements for process analytical technology. KW - Suspension Array KW - Immunoassay KW - Carbamazepine KW - Caffeine KW - Diclofenac KW - SAFIA PY - 2019 DO - https://doi.org/10.1021/acs.analchem.9b03040 SN - 0003-2700 VL - 91 IS - 20 SP - 12988 EP - 12966 PB - ACS Publications AN - OPUS4-49305 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schröder, Jakob A1 - Mishurova, Tatiana A1 - Fritsch, Tobias A1 - Serrano-Munoz, Itziar A1 - Evans, Alexander A1 - Sprengel, Maximilian A1 - Klaus, M. A1 - Genzel, C. A1 - Schneider, J. A1 - Bruno, Giovanni T1 - On the influence of heat treatment on microstructure and mechanical behavior of laser powder bed fused Inconel 718 N2 - A range of heat treatments have been developed for wrought Inconel 718 to obtain desired properties. For additively manufactured Inconel 718, the recently developed standard ASTM F3301 provides guidance for heat treatment of powder bed fusion specimens. Although this standard is based on standards developed for wrought Inconel 718, it does not include direct aging. Since direct aging reduces the number of processing steps, it can result in a post processing cost reduction if the desired properties are obtained. In this study, we characterized the microstructure and tensile behavior of Inconel 718 specimens produced by a laser powder bed fusion process. The specimens were heat treated according to two different routines after stress relieving: a full heat Treatment versus a one-step direct aging process. Differences in the resulting texture and grain morphology were observed. The ex-situ stress-strain behavior was broadly similar. However, a slight increase in yield strength was observed for the direct aged specimen. In order to understand this behavior, investigations with in-situ synchrotron Energy dispersive X-ray diffraction tensile testing revealed differences in the load partitioning among different Crystal directions. Importantly, the elastic anisotropy expressed by the magnitude of the diffraction elastic constants showed a dependency on the microstructures. KW - Electron microscopy KW - X-ray analysis KW - Inconel 718 KW - Additive Manufacturing KW - Mechanical behavior KW - Diffraction elastic constants PY - 2021 DO - https://doi.org/10.1016/j.msea.2020.140555 VL - 805 SP - 40555 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-52142 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -