TY - CONF A1 - Thiele, E. A1 - Erth, H. A1 - Helbig, R. A1 - Werth, K. A1 - Glötzl, R. A1 - Schneider, J. A1 - Nöther, Nils A1 - Wosniok, Aleksander A1 - Krebber, Katerina A1 - Schlurmann, T. A1 - Saathoff, F. T1 - Sensitive Textilstrukturen zur Deichüberwachung T2 - BAUTEX 2008, 8. Sächsisches Bautextilien-Symposium "Bauen mit Geokunststoffen" CY - Chemnitz, Deutschland DA - 2008-01-24 PY - 2008 SP - 1 EP - 5 CY - Chemnitz AN - OPUS4-17448 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gradt, Thomas A1 - Schneider, Thomas A1 - Lingertat, J. A1 - Hathiramani, D. T1 - MoS2-Schmierung für hochbelastete Stützelemente zwischen supraleitenden Magnetspulen T2 - 49. Tribologie-Fachtagung - Reibung, Schmierung und Verschleiß - Forschung und praktische Anwendungen CY - Göttingen, Deutschland DA - 2008-09-22 KW - Tribologie KW - Molybdändisulfid KW - Stick-Slip KW - Supraleitung KW - Kernfusion PY - 2008 SN - 978-3-00-025676-9 VL - I SP - 13/1 EP - 13/10 AN - OPUS4-18366 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gradt, Thomas A1 - Schneider, Thomas A1 - Lingertat, J. A1 - Hathiramani, D. A1 - Schauer, F. T1 - MoS2-Schmierung für hochbelastete Stützelemente zwischen supraleitenden Magnetspulen KW - Kernfusion KW - Supraleitende Magnete KW - Kryotribologie KW - Vakuumtribologie KW - Stick-Slip KW - MoS2 PY - 2009 SN - 0724-3472 VL - 56 IS - 5 SP - 24 EP - 28 PB - Expert Verlag CY - Renningen AN - OPUS4-20726 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schneider-Gloetzl, J. A1 - Gloetzl, R. A1 - Krebber, Katerina A1 - Liehr, Sascha A1 - Wendt, Mario A1 - Wosniok, Aleksander T1 - Geotechnical monitoring of construction activities by distributed fiber optic sensors embedded in geotextiles T2 - 5th European workshop on structural-health-monitoring 2010 CY - Sorrento, Italy DA - 2010-06-29 KW - Foundation engineering KW - Geotechnical monitoring KW - Smart textiles KW - Distributed fiber optic sensors KW - POF sensors KW - Brillouin sensors PY - 2010 IS - SS4-07 SP - 1 EP - 6 AN - OPUS4-21872 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schneider-Gloetzl, J. T1 - Geotechnical Monitoring of Construction Activities by Distributed Fibre Optic Sensors Embedded in Geotextiles T2 - 5th European Workshop on Structural Health Monitoring CY - Sorrento, Italy DA - 2010-06-29 PY - 2010 AN - OPUS4-22087 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Martínez, N.A. A1 - Schneider, Rudolf A1 - Messina, G.A. A1 - Raba, J. T1 - Modified paramagnetic beads in a microfluidic system for the determination of ethinylestradiol (EE2) in river water samples N2 - In this work, we have developed and characterized a novel microfluidic immunoassay methodology for rapid and sensitive quantification of ethinylestradiol (EE2) in river water samples. The detection of EE2 was carried out using a competitive direct immunoassay method based on the use of anti-EE2 polyclonal antibodies immobilized on magnetic microspheres 3-aminopropyl-modified manipulated for an external removable magnet. The EE2 present in the water sample was allowed to compete with EE2-horseradish peroxidase (HPR) conjugated for the immobilized anti-EE2 antibody. The HPR, in the presence of hydrogen peroxide (H2O2) catalyzes the oxidation of catechol (Q) whose back electrochemical reduction was detected on gold electrode at 0.0 V. The response current obtained from the product of enzymatic reaction is inversely proportional to the amount of EE2 in the water sample. The electrochemical detection can be done within 1 min and total assay time was 30 min. The calculated detection limits for electrochemical detection and the ELISA procedure are 0.09 and 0.32 ng L-1 respectively and the intra- and inter-assay coefficients of variation were below 5.8%. Our electrochemical immunosensor showed higher sensitivity and lower time consumed than the standard spectrophotometric detection ELISA method, which shows the potential for assessment of EE2 in river water samples. KW - Enzyme immunoassays KW - Ethinylestradiol KW - Paramagnetic beads KW - Horseradish peroxidase KW - Microfluidic KW - Flow injection analysis PY - 2010 DO - https://doi.org/10.1016/j.bios.2009.10.031 SN - 0956-5663 SN - 1873-4235 VL - 25 IS - 6 SP - 1376 EP - 1381 PB - Elsevier CY - Barking, Essex, UK AN - OPUS4-22188 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Klaffke, Dieter A1 - Schneider, Thomas A1 - Brand, J. A1 - Wittorf, R. T1 - Tribologisches Verhalten von DLC-Schichten in wässrigen Salzlösungen T2 - GfT-Jahrestagung Tribologie CY - Göttingen, Deutschland DA - 2005-09-26 KW - DLC-Schichten KW - Salzwasser KW - Korrosion KW - Schwingungsverschleiß PY - 2005 SN - 3-00-017102-9 SP - 34/1 EP - 34/10 PB - GfT CY - Moers AN - OPUS4-11027 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Richter, Matthias A1 - Jann, Oliver A1 - Kemski, J. A1 - Klingel, R. A1 - Schneider, Uwe A1 - Krocker, Christian T1 - Investigations on radon exhalation of different building materials N2 - The inhalation of 222Rn (radon) is one of the most important reasons for lung cancer, after smoking. Usually, the geological subsoil and the building ground are the dominant sources for enhanced indoor radon levels. Additionally, building materials can increase indoor radon concentrations when these materials contain higher contents of 226Ra (radium), especially in combination with low air exchange rates. For a realistic estimation of indoor radon concentrations, it is helpful to carry out measurements of radon exhalation rates from relevant materials using emission test chambers. In Germany, it is aspired to limit the total indoor radon concentration to 100 Bq/m3, whereby building materials should contribute at most 20 Bq/m3. Within a project financed by the German Institute for Construction Technology (DIBt), a practical oriented measurement procedure of the radon exhalation of building materials in accordance to ISO 16000-9 was developed to have a means for the assessment of these materials with respect to their indoor use. Test chambers with different volumes were used. The tested materials were mainly used for wall constructions (e.g., bricks, light-weight concrete) and have known specific radium activities and radon exhalation rates. T2 - Indoor Air 2011, 12th International conference on indoor air quality and climate CY - Austin, TX, USA DA - 05.06.2011 KW - Radon exhalation KW - Building material KW - Emission test chamber KW - Indoor air PY - 2011 IS - Paper 768 SP - 1 EP - 2 AN - OPUS4-24155 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Glötzl, R. A1 - Schneider Glötzl, J. A1 - Wosniok, Aleksander A1 - Krebber, Katerina A1 - Krywult, L. ED - Wintera, J. ED - Kosik, A. ED - Wity, A. T1 - Optical distributed sensing systems and possible applications in geotechnical measuring N2 - In comparison with traditional measuring Systems (pressure cells, piezometers and inclinometers which produce only point measurements) fibre optic sensors are well suited for spatiallydistributed monitoring purposes. The very tiny optical fibres of a diameter of less then 1 mm can operate as sensors in strong electromagnetic fields, under “harsh” explosive and Chemical environments and under ionizing radiation. T2 - XIV Dam monitoring international conference 'safetyof dams - new challenges' ('Bezpieczenstwo zapór - nowe wyzwania') CY - Walbrzych, Poland DA - 13.06.2011 KW - Fibre optic sensor KW - Spatial distributed sensor KW - Polymer optical fibre (POF) KW - Glass optical fibre (GOF) KW - POF OTDR KW - Brillouin sensor KW - BOTDA KW - BOFDA KW - Fibre Bragg grating (FBG) KW - Geosynthetics KW - Geotxtiles KW - Technical textiles PY - 2011 SN - 978-83-61102-53-3 N1 - Serientitel: Monografie - Instytutu Meteorologii i Gospodarki Wodnej – Series title: Monografie - Instytutu Meteorologii i Gospodarki Wodnej IS - Chapter 6 SP - 173 EP - 180 AN - OPUS4-24066 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nöther, N. A1 - Krebber, Katerina A1 - Schneider-Glötzl, J. T1 - An all-digital implementation of the Brillouin optical frequency domain analysis for long-range distributed strain and temperature monitoring N2 - For long-range measurements in geotechnical and industrial applications, distributed optical fiber sensors have become a tool of increasing importance throughout the past decade. Classic deformation monitoring (performed by strain gauges etc.) and temperature monitoring (Pt100 and alike) deliver data from fixed, single spots of a structure; quasidistributed measurements (fiber bragg gratings) provide a Chain of discrete measurement points along a limited sensing length. In contrast, an opticai fiber connected to a device for distributed strain and temperature sensing (DTSS) will provide a continuous profile of strain and temperature - spatially resolved down to less than 1 m - over a ränge of several tens of kilometers. In DTSS measurements, the nonlinear opticai effect of stimulated Brillouin Scattering (SBS) is employed: two light waves with a stable, tunable frequency offset are injected into opposite ends of the sensing fiber, where they will form a beat pattem, at which parts of the light will be scattered. By matching the frequency offset of the light waves to the propagation of acoustic fluctuation in the opticai fiber, a power transfer from one light wave to the other can be measured; since the acoustic propagation directly shifts with train and temperature of the fiber, these two quantities can be measured by tuning the light waves’ frequency offset. T2 - 8th International symposium on field measurements in geomechanics - FMGM 2011 CY - Berlin, Germany DA - 12.09.2011 PY - 2011 SP - 1 EP - 6 AN - OPUS4-24664 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst A1 - Amir, J. M. A1 - Schneider, N. T1 - New possibilities for quality assurance of diaphragm wall joints N2 - Diaphragm walls are used to provide a stable and watertight confinement for the construction of tunnels, Underground railway stations, deep basements and other structures requiring deep excavations. Water seepage and soil loss through the joints have occurred on several occasions, causing extensive damage. This may have been due to uncontrolled concrete flow between the joints, unexpected geologic conditions or just poor workmanship. Different ways of quality assurance are applied on construction sites. Most of them rely on recording Parameters of the construction equipment and conventional concrete quality control. In the frame of the EUREKA/ZIM project DiWaQ we have looked at several ways to perform non-destructive Quality control. Some methods are to be applied after excavation before concreting (phase 1); others after the wall is completed (phase 2). For phase 1 we have used two different principles for checking the shape of the excavation, especially the joint to existing panels. A mechanical device which can be adapted to the excavating Equipment was developed; field tested and validated on test and construction sites. It is described in detail in another paper in the same volume. A sonar-based device with a 10 mm resolution has shown good performance in the lab, but is still under development. For phase 2 different temperature sensors have been lowered into access holes to monitor the hydration heat developed during concrete curing. The same tubes can also be used to perform electromagnetic and ultrasonic crosshole measurements across or along joints to detect flaws. Especially the ultrasonic method has shown promising results on Validation specimen at the BAM test site at Horstwalde, but limitations as well. Success substantially depended on the joint type, flaw size and distance of the sensors to the joint. T2 - International conference on piling & deep foundations CY - Stockholm, Sweden DA - 21.05.2014 KW - Diaphragm walls KW - Joints KW - Integrity KW - Crosshole sonic logging KW - Sonar PY - 2014 UR - http://www.piletest.com/papers/Niederleithinger_et_al_2014_Stockholm_2014.pdf SP - 911 EP - 918 AN - OPUS4-31201 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Anker, Andy S. A1 - Aspuru-Guzik, Alán A1 - Ben Mahmoud, Chiheb A1 - Bennett, Sophie A1 - Briling, Ksenia R. A1 - Changiarath, Arya A1 - Chong, Sanggyu A1 - Collins, Christopher M. A1 - Cooper, Andrew I. A1 - Crusius, Daniel A1 - Darmawan, Kevion K. A1 - Das, Basita A1 - David, Nicholas A1 - Day, Graeme M. A1 - Deringer, Volker L. A1 - Duarte, Fernanda A1 - Eardley-Brunt, Annabel A1 - Evans, Matthew L. A1 - Evans, Rob A1 - Fairlamb, Ian A1 - Franklin, Barnabas A. A1 - Frey, Jeremy A1 - Ganose, Alex M. A1 - Goulding, Mark A1 - Hafizi, Roohollah A1 - Hakkennes, Matthijs A1 - Hickey, Niamh A1 - James, Gillian A1 - Jelfs, Kim E. A1 - Kalikadien, Adarsh V. A1 - Kapil, Venkat A1 - Koczor-Benda, Zsuzsanna A1 - Krammer, Ferdinand A1 - Kulik, Heather J. A1 - Kumar, Vishank A1 - Kuttner, Christian A1 - Lam, Erwin A1 - Lou, Yuchen A1 - Mante, Eltjo A1 - Martin, Jennie A1 - Mroz, Austin M. A1 - Nematiaram, Tahereh A1 - Pare, Charles W. P. A1 - Patra, Sarbani A1 - Proudfoot, James A1 - Ruscic, Branko A1 - Ryder, Matthew R. A1 - Sakaushi, Ken A1 - Saßmannshausen, Jörg A1 - Savoie, Brett M. A1 - Schneider, Nadine A1 - Schwaller, Philippe A1 - Skjelstad, Bastian Bjerkem A1 - Sun, Wenhao A1 - Szczypiński, Filip T. A1 - Torrisi, Steven A1 - Ueltzen, Katharina A1 - Vishnoi, Shubham A1 - Walsh, Aron A1 - Wang, Xinwei A1 - Wilson, Chloe A1 - Wu, Ruiqi A1 - Zeitler, Jakob T1 - Discovering structure–property correlations: General discussion N2 - This article is a discussion of the paper "Web-BO: Towards increased accessibility of Bayesian optimisation (BO) for chemistry" by Austin M. Mroz, Piotr N. Toka, Ehecatl Antonio del Río Chanona and Kim E. Jelfs (Faraday discussions, 2025, 256, 221-234). KW - Materials design KW - Machine learning KW - Automation KW - Materials discovery PY - 2025 DO - https://doi.org/10.1039/d4fd90062f SN - 1359-6640 SN - 1364-5498 VL - 256 IS - Themed collection: Data-driven discovery in the chemical sciences SP - 373 EP - 412 PB - Royal Society of Chemistry (RSC) CY - Cambridge AN - OPUS4-62208 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Massiot, D. A1 - Müller, D. A1 - Hübert, Thomas A1 - Schneider, M. A1 - Kentgens, A. A1 - Coté, B. A1 - Coutures, J. A1 - Gessner, W. T1 - Double rotation and magic-angle spinning nuclear magnetic resonance study of 27Al: reexamination of the aluminium borate 9Al2O3 · 2B2O3 N2 - 27Al nuclear magnetic resonance spectra of polycrystalline aluminium borate 9Al2O3 · 2B2O3 have been measured in double rotation at 11.7 and 7.0 T and high-speed magic-angle spinning at 7.0, 9.4, 11.7, 14.1 and 17.6 T. Spinning sidebands from the satellite transitions were observed at 7.0 and 14.1 T. Each of the four structural aluminium sites [Al(IV), Al(V)(1), Al(V)(2) and Al(VI)] are observed, characterised and assigned in the spectra. The obtained parameter set gives a fully consistent interpretation in agreement with the crystal structure of the compound. KW - Aluminium KW - Kernresonanz, magnetisch KW - Winkel, magisch KW - Doppelrotation PY - 1995 DO - https://doi.org/10.1016/0926-2040(95)00021-H SN - 0926-2040 SN - 1527-3326 VL - 5 IS - 2 SP - 175 EP - 180 PB - Academ. Press CY - Orlando, Fla. AN - OPUS4-639 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Jann, Oliver A1 - Köppke, J. A1 - Lehmann, R. A1 - Schneider, Uwe T1 - Messungen der Radonexhalation aus Baustoffen unter Modellklimabedingungen PY - 2003 SN - 0949-8036 SN - 0039-0771 SN - 1436-4891 VL - 63 IS - 1/2 SP - 49 EP - 52 PB - Springer-VDI-Verl. CY - Düsseldorf AN - OPUS4-2279 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Jann, Oliver A1 - Richter, Matthias A1 - Kemski, J. A1 - Klingel, R. A1 - Schneider, Uwe A1 - Krocker, Christian T1 - Entwicklung einer praxisnahen Prüfmethode zur Bestimmung der Radon-Exhalation aus Bauprodukten KW - Radon KW - Baumaterialien KW - Emissionsprüfkammer KW - Prüfmethode PY - 2012 SN - 978-3-8167-8723-5 VL - T 3277 SP - 1 EP - 74 PB - Fraunhofer IRB Verl. CY - Stuttgart AN - OPUS4-26572 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Richter, Matthias A1 - Jann, Oliver A1 - Kemski, J. A1 - Schneider, Uwe A1 - Krocker, Christian A1 - Hoffmann, B. T1 - Determination of radon exhalation from construction materials using VOC emission test chambers N2 - The inhalation of 222Rn (radon) decay products is one of the most important reasons for lung cancer after smoking. Stony building materials are an important source of indoor radon. This article describes the determination of the exhalation rate of stony construction materials by the use of commercially available measuring devices in combination with VOC emission test chambers. Five materials – two types of clay brick, clinker brick, light-weight concrete brick, and honeycomb brick – generally used for wall constructions were used for the experiments. Their contribution to real room concentrations was estimated by applying room model parameters given in ISO 16000-9, RP 112, and AgBB. This knowledge can be relevant, if for instance indoor radon concentration is limited by law. The test set-up used here is well suited for application in test laboratories dealing with VOC emission testing. KW - Radon exhalation KW - Radon measurement KW - Building material KW - Emission test chamber KW - Indoor air quality KW - Real room radon concentrations PY - 2013 DO - https://doi.org/10.1111/ina.12031 SN - 0905-6947 SN - 1600-0668 VL - 23 IS - 5 SP - 397 EP - 405 PB - Danish Techn. Pr. CY - Copenhagen AN - OPUS4-29408 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Martínez, N.A. A1 - Pereira, S.V. A1 - Bertolino, F.A. A1 - Schneider, Rudolf A1 - Messina, G.A. A1 - Raba, J. T1 - Electrochemical detection of a powerful estrogenic endocrine disruptor: ethylestradiol in water samples through bioseparation procedure N2 - The synthetic estrogen ethinylestradiol (EE2) is an active component of oral contraceptives (OCs), considered as an endocrine disrupting compound (EDC). It is excreted from humans and released via sewage treatment plant effluents into aquatic environments. EDCs are any environmental pollutant chemical that, once incorporated into an organism, affects the hormonal balance of various species including humans. Its presence in the environment is becoming of great importance in water quality. This paper describes the development of an accurate, sensitive and selective method for capture, preconcentration and determination of EE2 present in water samples using: magnetic particles (MPs) as bioaffinity support for the capture and preconcentration of EE2 and a glassy carbon electrode modified with multi-walled carbon nanotubes (MWCNTs/GCE) as detection system. The capture procedure was based on the principle of immunoaffinity, the EE2 being extracted from the sample using the anti-EE2 antibodies (anti-EE2 Ab) which were previously immobilized on MPs. Subsequently the analyte desorption was done employing a sulfuric acid solution and the determination of the EE2 in the pre-concentrated solution was carried out by square wave voltammetry (SWV). This method can be used to determine EE2 in the range of 0.035–70 ng L-1 with a detection limit (LOD) of 0.01 ng L-1 and R.S.D. < 4.20%. The proposed method has been successfully applied to the determination of EE2 in water samples and it has promising analytical applications for the direct determination of EE2 at trace levels. KW - Magnetic particles KW - Bioseparation KW - Ethinylestradiol KW - Electrochemistry KW - Immunoassay KW - Elektrochemischer Sensor KW - Endokrine Disruptoren KW - Hormone KW - EE2 KW - Östrogene PY - 2012 DO - https://doi.org/10.1016/j.aca.2012.02.033 SN - 0003-2670 SN - 1873-4324 SN - 0378-4304 VL - 723 SP - 27 EP - 32 PB - Elsevier CY - Amsterdam AN - OPUS4-25656 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carvalho, J.J.D. A1 - Bahlmann, Arnold A1 - Schneider, Rudolf T1 - ELISA goes Berlin - Bestimmung von Carbamazepin, Cetrizin und Coffein in Berliner Gewässern N2 - Sensitive und selektive Immunoassays unterstützen Untersuchungen im Vollzug der EU Wasserrahmenrichtlinie. Sie erlauben, eine hohe Anzahl von Proben ohne Anreicherungsschritte zu untersuchen und ermöglichen daher den Aufbau eines zeitlich und räumlich engmaschigen Messnetzes. Mit Hilfe von ELISA (enzymelinked immunosorbent assay) wurde ein Gewässerscreening in Berlin durchgeführt. KW - ELISA KW - Koffein KW - Immunoassay KW - Oberflächenwasser KW - Wasseranalytik PY - 2012 SN - 0016-3538 VL - 4 SP - 278 EP - 281 PB - GIT-Verlag CY - Darmstadt AN - OPUS4-27518 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schneider, Rudolf J. T1 - Evaluating the Normalization Potential of Anthropogenic Markers in Wastewater: Monitoring Influents of German Treatment Plants by ELISA N2 - Wastewater-based epidemiology (WBE) has emerged as a vital tool for pandemic preparedness, offering early warning capabilities and supporting public health interventions. In Germany, combined sewer systems are prevalent, leading to fluctuations in wastewater volume and com-position due to rainwater inflow, especially through street drains. This variability complicates the quantitative measurement of pathogens and pollutants in wastewater. While human excretion provides constant inputs, these parameters are often non-specific, lost, or degraded during transport. Pharmaceuticals—such as carbamazepine, diclofenac, and clarithromycin—as well as commonly consumed substances like caffeine, exhibit sufficiently high concentrations and good chemical stability in wastewater and are not subject to seasonal fluctuations. Antibody-based methods, particularly Enzyme-Linked Immunosorbent Assays (ELISA), offer a cost-effective alternative to complex chromatographic techniques for monitoring anthropogenic markers. They demonstrate superior normalization quality compared to the frequently used quantitative PCR-based marker Pepper mild mottle virus (PMMoV). T2 - 6th International Conference on Risk Assessment of Pharmaceuticals in the Environment - ICRAPHE CY - Aveiro, Portugal DA - 20.10.2025 KW - Carbamazepin KW - Koffein KW - Spurenstoffe KW - Anthropogener Marker Immunoassay PY - 2025 AN - OPUS4-64432 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pauli, J. A1 - Güttler, Arne A1 - Schneider, T. A1 - Würth, Christian A1 - Resch-Genger, Ute T1 - Fluorescence Quantum Yield Standards for the UV/Visible/NIR: Development, Traceable Characterization, and Certification N2 - The rational design of next generation molecular and nanoscale reporters and the comparison of different emitter classes require the determination of the fluorometric key performance parameter fluorescence quantum yield (Φf), i.e., the number of emitted photons per number of absorbed photons. Main prerequisites for reliable Φf measurements, which are for transparent luminophore solutions commonly done relative to a reference, i.e., a fluorescence quantum yield standard of known Φf, are reliable and validated instrument calibration procedures to consider wavelength-, polarization-, and time-dependent instrument specific signal contributions, and sufficiently well characterized fluorescence quantum yield standards. As the standard’s Φf value directly contributes to the calculation of the sample’s Φf, its accuracy presents one of the main sources of uncertainty of relative Φf measurements. To close this gap, we developed a first set of 12 fluorescence quantum yield standards, which absorb and emit in the wavelength region of 330−1000 nm and absolutely determined their Φf values with two independently calibrated integrating sphere setups. Criteria for standard selection and the configuration of these novel fluorescence reference materials are given, and the certification procedure is presented including homogeneity and stability studies and the calculation of complete uncertainty budgets for the certified Φf values. The ultimate goal is to provide the community of fluorescence users with available reference materials as a basis for an improved comparability and reliability of quantum yield data since the measurement of this spectroscopic key property is an essential part of the characterization of any new emitter. KW - Optical spectroscopy KW - Traceability KW - Reference product KW - Dye KW - Fluorescence KW - Quantum yield KW - Reference material KW - Reference data KW - Certification KW - Quality assurance PY - 2023 DO - https://doi.org/10.1021/acs.analchem.2c05530 VL - 95 SP - 5671 EP - 5677 PB - American Chemical Society AN - OPUS4-58151 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schneider, Joachim A1 - Adamczyk, Burkart A1 - Ebert, D. A1 - Ehrenberg, A. A1 - Schraut, Katharina A1 - Gerlach, J. A1 - Wendt, K. A1 - Algermissen, D. A1 - Adam, Christian ED - Rogge, Andreas ED - Meng, Birgit T1 - Erzeugung von Bindemitteln aus Stahlwerksschlacken N2 - Die geplante Transformation der Stahlindustrie innerhalb der nächsten 20 Jahre hat aufgrund des mit ihr verbundenen Auslaufens der Hüttensanderzeugung Konsequenzen für die Zementindustrie, deren Abmilderung Gegenstand der Forschungsprojekte SlagCEM und DRI-EOS ist. Ersteres untersucht die Rückgewinnung von Eisen aus LD-Konverter-Schlacke bei gleichzeitiger Herstellung eines mineralischen Produktes mit zementä- ren Eigenschaften. Zweiteres befasst sich mit der Generierung eines Hüttensandersatzes aus Lichtbogen- ofenschlacke mit Rückgewinnung von Schwermetallen sowie deren Umwelteffekt bei Verbleib in der Schlacke. T2 - 11. Jahrestagung des DAfStb mit 63. Forschungskolloquium der BAM Green Intelligent Building CY - Berlin, Germany DA - 16.10.2024 KW - Bindemittel KW - Stahlwerksschlacke PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-613127 SN - 978-3-9818564-7-7 SP - 78 EP - 89 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-61312 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Laquai, René A1 - Müller, Bernd R. A1 - Schneider, J. A1 - Kupsch, Andreas A1 - Bruno, Giovanni T1 - Using SXRR to Probe the Nature of Discontinuities in SLM Additive Manufactured Inconel 718 Specimens N2 - The utilization of additive manufacturing (AM) to fabricate robust structural components relies on understanding the nature of internal anomalies or discontinuities, which can compromise the structural integrity. While some discontinuities in AM microstructures stem from similar mechanisms as observed in more traditional processes such as casting, others are unique to the AM process. Discontinuities in AM are challenging to detect, due to their submicron size and orientation dependency. Toward the goal of improving structural integrity, minimizing discontinuities in an AM build requires an understanding of the mechanisms of formation to mitigate their occurrence. This study utilizes various techniques to evaluate the shape, size, nature and distribution of discontinuities in AM Inconel 718, in a non-hot isostatic pressed (HIPed) as-built, non-HIPed and direct age, and HIPed with two step age samples. Non-destructive synchrotron radiation refraction and transmission radiography (SXRR) provides additional information beyond that obtained with destructive optical microscopy. SXRR was able to distinguish between voids, cracks and lack of melt in, due to its sensitivity to the orientation of the discontinuity. KW - Additive manufacturing KW - X-ray refraction radiography KW - INCONEL 718 KW - Selective laser melting PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-509836 DO - https://doi.org/10.1007/s11661-020-05847-5 SN - 1543-1940 VL - 51 IS - 8 SP - 4146 EP - 4157 PB - Springer AN - OPUS4-50983 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Riedel, Soraya A1 - Hülagü, Deniz A1 - Bennet, Francesca A1 - Carl, Peter A1 - Flemig, Sabine A1 - Schmid, Thomas A1 - Schenk, J. A. A1 - Hodoroaba, Vasile-Dan A1 - Schneider, Rudolf T1 - Electrochemical Immunomagnetic Ochratoxin A Sensing: Steps Forward in the Application of 3,3’,5,5’- Tetramethylbenzidine in Amperometric Assays N2 - Electrochemical methods offer great promise in meeting the demand for user-friendly on-site devices for Monitoring important parameters. The food industry often runs own lab procedures, for example, for mycotoxin analysis, but it is a major goal to simplify analysis, linking analytical methods with smart technologies. Enzyme-linked immunosorbent assays, with photometric detection of 3,3’,5,5’-tetramethylbenzidine (TMB),form a good basis for sensitive detection. To provide a straightforward approach for the miniaturization of the detectionstep, we have studied the pitfalls of the electrochemical TMB detection. By cyclic voltammetry it was found that the TMB electrochemistry is strongly dependent on the pH and the electrode material. A stable electrode response to TMB could be achieved at pH 1 on gold electrodes. We created a smartphonebased, electrochemical, immunomagnetic assay for the detection of ochratoxin A in real samples, providing a solid basis forsensing of further analytes. KW - Ochratoxin A KW - Amperometry KW - Cyclic voltammetry KW - Electrochemistry KW - Immunoassay PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-530421 DO - https://doi.org/10.1002/celc.202100446 N1 - Geburtsname von Riedel, Soraya: Höfs, S. - Birth name of Riedel, Soraya: Höfs, S. VL - 8 IS - 13 SP - 2597 EP - 2606 AN - OPUS4-53042 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carl, Peter A1 - Sarma, Dominik A1 - Gregório, Bruno J. R. A1 - Hoffmann, Kristin A1 - Lehmann, Andreas A1 - Rurack, Knut A1 - Schneider, Rudolf T1 - Wash-Free Multiplexed Mix-and-Read Suspension Array Fluorescence Immunoassay for Anthropogenic Markers in Wastewater N2 - Pharmaceuticals, certain food ingredients, and mammalian endogenous metabolic products in wastewater are mostly of human origin. They are anthropogenic markers. Proper knowledge of their levels in wastewater helps to track sources of pollutants in natural waters and allows for calculation of removal efficiencies in wastewater Treatment plants. Here, we describe the development and application of an indirect competitive, multiplexing suspension Array fluorescence immunoassay (SAFIA) for the detection of carbamazepine (CBZ), diclofenac (DCF), caffeine (CAF), and isolithocholic acid (ILA) in wastewater, covering those classes of anthropogenic markers. The assay consists of haptens covalently conjugated to fluorescence-encoded polystyrene core/silica shell microparticles to create a site for competitive binding of the antibodies (Abs). Bound Abs are then stained with fluorophore-labeled Abs. Encoding and signaling fluorescence of the particles are determined by an automated flow cytometer. For compatibility of the immunoassay with the 96-well microtiter plate format, a stop reagent, containing formaldehyde, is used. This enables a wash-free procedure while decreasing time-to-result. Detection limits of 140 ± 40 ng/L for CBZ, 180 ± 110 ng/L for CAF, 4 ± 3 ng/L for DCF, and 310 ± 70 ng/L for ILA are achieved, which meet the sensitivity criteria of wastewater analysis. We demonstrate the applicability of SAFIA to real wastewater samples from three different wastewater Treatment plants, finding the results in good agreement with LC-MS/MS. Moreover, the accuracy in general exceeded that from classical ELISAs. We therefore propose SAFIA as a quick and reliable approach for wastewater analysis meeting the requirements for process analytical technology. KW - Suspension Array KW - Immunoassay KW - Carbamazepine KW - Caffeine KW - Diclofenac KW - SAFIA PY - 2019 DO - https://doi.org/10.1021/acs.analchem.9b03040 SN - 0003-2700 VL - 91 IS - 20 SP - 12988 EP - 12966 PB - ACS Publications AN - OPUS4-49305 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schröder, Jakob A1 - Mishurova, Tatiana A1 - Fritsch, Tobias A1 - Serrano-Munoz, Itziar A1 - Evans, Alexander A1 - Sprengel, Maximilian A1 - Klaus, M. A1 - Genzel, C. A1 - Schneider, J. A1 - Bruno, Giovanni T1 - On the influence of heat treatment on microstructure and mechanical behavior of laser powder bed fused Inconel 718 N2 - A range of heat treatments have been developed for wrought Inconel 718 to obtain desired properties. For additively manufactured Inconel 718, the recently developed standard ASTM F3301 provides guidance for heat treatment of powder bed fusion specimens. Although this standard is based on standards developed for wrought Inconel 718, it does not include direct aging. Since direct aging reduces the number of processing steps, it can result in a post processing cost reduction if the desired properties are obtained. In this study, we characterized the microstructure and tensile behavior of Inconel 718 specimens produced by a laser powder bed fusion process. The specimens were heat treated according to two different routines after stress relieving: a full heat Treatment versus a one-step direct aging process. Differences in the resulting texture and grain morphology were observed. The ex-situ stress-strain behavior was broadly similar. However, a slight increase in yield strength was observed for the direct aged specimen. In order to understand this behavior, investigations with in-situ synchrotron Energy dispersive X-ray diffraction tensile testing revealed differences in the load partitioning among different Crystal directions. Importantly, the elastic anisotropy expressed by the magnitude of the diffraction elastic constants showed a dependency on the microstructures. KW - Electron microscopy KW - X-ray analysis KW - Inconel 718 KW - Additive Manufacturing KW - Mechanical behavior KW - Diffraction elastic constants PY - 2021 DO - https://doi.org/10.1016/j.msea.2020.140555 VL - 805 SP - 40555 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-52142 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Singh, Chandan A1 - Riedel, Soraya A1 - Konthur, Zoltán A1 - Hodoroaba, Vasile-Dan A1 - Radnik, Jörg A1 - Schenk, J. A. A1 - Schneider, Rudolf T1 - Functionalized Ti3C2Tx nanosheets based biosensor for point-of-care detection of SARS-CoV‑2 antigen N2 - MXenes are considered a promising class of two-dimensional materials with extraordinary physical and electrochemical properties. Distinguished features like high specific surface area and outstanding electrical conductivity make them suitable for electrochemical biosensing applications. Here, we report the development of a biosensor involving the functionalized MXene−titanium carbide nanosheets (Ti3C2Tx-NS) and monoclonal antibodies against the SARS-CoV-2 nucleocapsid protein (anti-SARS-CoV-2 mAb) to design a point-of-care device for detection of the SARS-CoV-2 nucleocapsid protein (SARS-CoV-2 NP) antigen. Few-layered titanium carbide nanosheets (denoted as FL-Ti3C2Tx-NS) have been synthesized using a single-step etching and delamination method and characterized using optical and electron microscopy techniques revealing the suitability for immunosensing applications. Binding studies revealed the excellent affinity between the biosensor and the SARS-CoV-2 NP. Electrochemical detection of SARS-CoV-2 NP is performed using differential pulse voltammetry and read by a smartphone-based user interface. The proposed FL-Ti3C2Tx-NS based biosensor offers the detection of SARS-CoV-2 NP with a limit of detection of 0.91 nM in a wide detection range in spiked saliva samples. Additionally, there is no cross-reactivity in the presence of potential interferants like SARS-CoV-2 spike glycoprotein and bovine serum albumin. These findings demonstrate the potential of MXenes in developing a rapid and reliable tool for SARS-CoV-2 NP detection. While we report the biosensing of SARS-CoV-2 NP, our system also paves the way for the detection of other SARS-CoV-2 antigens like spike protein or other biomolecules based on antigen−antibody interactions. KW - Antigen testing KW - Few-layered titanium carbide nanosheets KW - SARS-CoV-2 nucleocapsid protein KW - Label-free detection KW - Electrochemical immunosensor PY - 2023 DO - https://doi.org/10.1021/acsaenm.2c00118 SN - 2771-9545 N1 - Geburtsname von Riedel, Soraya: Höfs, S. - Birth name of Riedel, Soraya: Höfs, S. VL - 1 IS - 1 SP - 495 EP - 507 PB - American Chemical Society CY - Washington, DC AN - OPUS4-56931 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Guehrs, E. A1 - Schneider, M. A1 - Günther, Ch. M. A1 - Hessing, P. A1 - Heitz, K. A1 - Wittke, D. A1 - López-Serrano Oliver, Ana A1 - Jakubowski, Norbert A1 - Plendl, J. A1 - Eisebitt, S. A1 - Haase, A. T1 - Quantification of silver nanoparticle uptake and distribution within individual human macrophages by FIB/SEM slice and view N2 - Quantification of nanoparticle (NP) uptake in cells or tissues is very important for safety assessment. Often, electron microscopy based approaches are used for this purpose, which allow imaging at very high resolution. However, precise quantification of NP numbers in cells and tissues remains challenging. The aim of this study was to present a novel approach, that combines precise quantification of NPs in individual cells together with high resolution imaging of their intracellular distribution based on focused ion beam/ scanning electron microscopy (FIB/SEM) slice and view approaches. KW - Nanoparticles KW - FIB/SEM slice and view KW - Absolute dose KW - Cellular internalization KW - Macrophage PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-400626 DO - https://doi.org/10.1186/s12951-017-0255-8 SN - 1477-3155 VL - 15 SP - Article 21, 1 EP - 11 AN - OPUS4-40062 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Szczerba, Wojciech A1 - Zukrowski, J. A1 - Przybylski, M. A1 - Sikora, M. A1 - Safonova, O. A1 - Shmeliov, A. A1 - Nicolosi, V. A1 - Schneider, M. A1 - Granath, T. A1 - Oppmann, M. A1 - Straßer, M. A1 - Mandel, K. T1 - Pushing up the magnetisation values for iron oxide nanoparticles via zinc doping: X-ray studies on the particle's sub-nano structure of different synthesis routes N2 - The maximum magnetisation (saturation magnetisation) obtainable for iron oxide nanoparticles can be increased by doping the nanocrystals with non-magnetic elements such as zinc. Herein, we closely study how only slightly different synthesis approaches towards such doped nanoparticles strongly influence the resulting sub-nano/atomic structure. We compare two co-precipitation approaches, where we only vary the base (NaOH versus NH3), and a thermal decomposition route. These methods are the most commonly applied ones for synthesising doped iron oxide nanoparticles. The measurable magnetisation change upon zinc doping is about the same for all systems. However, the sub-nano structure, which we studied with Mössbauer and X-ray absorption near edge spectroscopy, differs tremendously. We found evidence that a much more complex picture has to be drawn regarding what happens upon Zn doping compared to what textbooks tell us about the mechanism. Our work demonstrates that it is crucial to study the obtained structures very precisely when “playing” with the atomic order in iron oxide nanocrystals. KW - Magnetic nanoparticles KW - Zinc ferrite KW - magnetic saturation KW - Mössbauer KW - XAFS KW - Synthesis KW - XRD PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-379583 DO - https://doi.org/10.1039/C6CP04221J VL - 18 SP - 25221 EP - 25229 PB - RSC Publishing AN - OPUS4-37958 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Fischer, J. A1 - Straub, D. A1 - Schneider, Ronald A1 - Thöns, Sebastian A1 - Rücker, Werner T1 - Intelligente Brücke - Zuverlässigkeitsbasierte Bewertung von Brückenbauwerken unter Berücksichtigung von Inspektions- und Überwachungsergebnissen N2 - Der vorliegende Bericht beschreibt Konzepte für eine intelligente Brücke auf der Grundlage einer zuverlässigkeitsbasierten Zustandsbewertung unter Berücksichtigung von Bauwerksinformationen, welche aus Prüfungen, Inspektionen und Überwachung gewonnen werden. Das Brückensystem wird durch ein Modell beschrieben, welches den zentralen Teil des Konzeptes darstellt. Das Modell wird in Schädigungsmodelle und ein Tragwerkssystem-Modell unterteilt. Dieses Modell wird a-priori durch die Eingangsdaten (welche etwa die Geometrie, die Materialien und die Verwendung der Brücke beschreiben) charakterisiert. Aus diesen ergeben sich dann auch die Ausgangsmodelle. Um die signifikanten Streuungen und Unsicherheiten adäquat abzubilden sind diese Modelle probabilistisch. Das Modell liefert eine sich kontinuierlich ändernde probabilistische Zustandsbewertung. Die Zustandsbewertung gibt eine Aussage über den Zustand und die Zuverlässigkeit des Brückensystems und seiner Bauteile und dient als Grundlage für die Planung und die Optimierung von Maßnahmen. Die Verwendung von Resultaten aus Inspektionen, Prüfungen und Überwachungen erfolgt durch eine Aktualisierung der Modellparameter. Die Aktualisierung beruht auf der Methode der Bayes'schen Aktualisierung und wird auf der Grundlage der entwickelten Klassifizierung der Bauwerksinformationen mit entsprechenden Methoden durchgeführt. Dieses Verfahren erlaubt es, alle Informationen in konsistenter Weise in ein einziges Modell einfließen zu lassen. Dabei wird die Genauigkeit und Aussagekraft der gewonnenen Daten und Beobachtungen explizit berücksichtigt. Durch die Aktualisierung der Modellparameter unter Berücksichtigung von Systemeffekten wird die Zustandsbewertung der Bauteile und des Brückensystems aktualisiert. Das ermöglicht die Planung und die Optimierung von Maßnahmen unter Berücksichtigung der Bauwerksinformationen. Auf diese Weise wird die intelligente Brücke mit Inspektionen und Überwachungen zu einem adaptiven System, welches sich Veränderungen anpassen kann.---------------------------------------------------------------------------------------------------------------------------------------------------------------------------This report describes concepts for an intelligent bridge on the basis of a reliability-based condition assessment utilizing inspection and monitoring data. The central part of the concept is a model describing the bridge system. The overall bridge model is comprised of deterioration models and a mechanical system model of the structure. The model is a-priori characterized by the input data (such as the geometry, the materials, and the utilization of the bridge). Significant uncertainties in the deterioration modeling as well as the load conditions motivate a probabilistic modeling. The model enables a continuously updated probabilistic condition assessment. It provides information about the condition and the reliability of the bridge system and its components and serves as a basis for the planning and the optimization of maintenance actions. Inspection, measurement, and monitoring information are included by updating the model parameters. Bayesian updating is utilized for the updating of the model parameters and is performed on the basis of the developed classification of structural information and the corresponding procedures. These methodologies allow to consistently incorporate all available information into the model and the prediction. Thereby, the precision and the validity of the data and observations are explicitly accounted for. The condition assessment of the bridge system and its components is updated by updating the model parameters, and maintenance actions can be planned and optimized taking into account all available information in a rational and consistent manner. In this way, the intelligent bridge with inspections, measurements, and monitoring information becomes an adaptive system, which has the ability to adjust to changes. KW - Berechnung KW - Brücke KW - Dauerhaftigkeit KW - Deutschland KW - Echtzeit KW - Forschungsbericht KW - Kontinuierlich KW - Kontrolle KW - Messung KW - Prognose KW - Prüfverfahren KW - Rechenmodell KW - Sachschaden KW - Tragfähigkeit KW - Wahrscheinlichkeit KW - Zustandsbewertung PY - 2014 UR - http://bast.opus.hbz-nrw.de/volltexte/2014/768/pdf/BASt_B_99_ELBA_PDF.pdf SN - 978-3-95606-078-6 SN - 0943-9293 IS - B 99 SP - 1 EP - 111 PB - Fachverlag NW in der Carl Schünemann Verlag GmbH CY - Bremen AN - OPUS4-31300 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Büchner, T. A1 - Drescher, D. A1 - Merk, V. A1 - Traub, Heike A1 - Guttmann, P. A1 - Werner, St. A1 - Jakubowski, Norbert A1 - Schneider, G. A1 - Kneipp, J. T1 - Biomolecular environment, quantification, and intracellular interaction of multifunctional magnetic SERS nanoprobes N2 - Multifunctional composite nanoprobes consisting of iron oxide nanoparticles linked to silver and gold nanoparticles, Ag–Magnetite and Au–Magnetite, respectively, were introduced by endocytic uptake into cultured fibroblast cells. The cells containing the non-toxic nanoprobes were shown to be displaceable in an external magnetic field and can be manipulated in microfluidic channels. The distribution of the composite nanostructures that are contained in the endosomal system is discussed on the basis of surfaceenhanced Raman scattering (SERS) mapping, quantitative laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) micromapping, and cryo soft X-ray tomography (cryo soft-XRT). Cryo soft-XRT of intact, vitrified cells reveals that the composite nanoprobes form intra-endosomal aggregates. The nanoprobes provide SERS signals from the biomolecular composition of their surface in the endosomal environment. The SERS data indicate the high stability of the nanoprobes and of their plasmonic properties in the harsh environment of endosomes and lysosomes. The spectra point at the molecular composition at the surface of the Ag–Magnetite and Au–Magnetite nanostructures that is very similar to that of other Composite structures, but different from the composition of pure silver and gold SERS nanoprobes used for intracellular investigations. As shown by the LA-ICP-MS data, the uptake efficiency of the magnetite composites is approximately two to three times higher than that of the pure gold and silver nanoparticles. KW - Nanoparticles KW - SERS KW - Cell KW - LA-ICP-MS KW - X-ray tomography PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-371811 DO - https://doi.org/10.1039/c6an00890a SN - 0003-2654 VL - 141 IS - 17 SP - 5096 EP - 5106 PB - Royal Society of Chemistry CY - Cambridge, UK AN - OPUS4-37181 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Szczerba, Wojciech A1 - Schneider, M. A1 - Żukrowski, J. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Riesemeier, Heinrich A1 - Sikora, M. A1 - Mandel, K. T1 - Spectroscopic Study of the Role of Metal Ions in the Adsorption Process of Phosphate in Nanoscaled Adsorbers Based on Metal (Zn/ Fe/Zr) Oxyhydroxides N2 - Currently great effort is made to find materials and technologies for the recycling of phosphate from wastewater. Herein, we present an in-depth study of the Phosphate adsorption mechanism of a promising adsorber material, a Zn−Fe−Zr oxyhydroxide-based nanostructured precipitate. The behavior of the multicomponent nanomaterial, consisting of both crystalline and amorphous parts, is investigated via X-ray absorption fine structure spectroscopy and Mössbauer spectroscopy, revealing the importance of the nanostructured composition for the phosphate adsorption. We found evidence that adsorption takes place especially in the vicinity of iron sites in the amorphous part of the material. KW - Zn-Fe-Zr nanoparticles KW - Adsorption of phosphate KW - XAFS KW - Catalysis PY - 2017 DO - https://doi.org/10.1021/acs.jpcc.7b04773 SN - 1932-7447 VL - 121 IS - 45 SP - 25033 EP - 25042 PB - ACS Publications AN - OPUS4-43348 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wilde, L. A1 - Radnik, J. A1 - Schneider, M. A1 - Herein, D. A1 - Riesemeier, Heinrich A1 - Radtke, Martin T1 - In situ TEY cell for XAS measurements at the BAMline PY - 2004 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2003.pdf#page=283 SN - 0179-4159 SP - 283 EP - 285 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-3508 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schneider, Ronald A1 - Fischer, J. T1 - Intelligente Bauwerke - Zuverlässigkeitsbasierte Bewertung von Brückenbauwerken unter Berücksichtigung von Inspektions- und Überwachungsergebnissen T2 - BASt Bundesanstalt für Staßenwesen, Betreuungstreffen "Intelligente Bauwerke" CY - Bergisch Gladbach, Germany DA - 2012-11-28 PY - 2012 AN - OPUS4-27198 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nusser, K. A1 - Mosbauer, T. A1 - Schneider, G. J. A1 - Brandt, K. A1 - Weidemann, Gerd A1 - Goebbels, Jürgen A1 - Riesemeier, Heinrich A1 - Göritz, D. T1 - Silica dispersion in styrene butadiene rubber composites studied by synchrotron tomography N2 - By means of synchrotron X-ray computed tomography, model composites consisting of silica and styrene–butadiene rubber were studied with a very high spatial resolution. By our analysis technique we were able to determine the nano- and micro dispersion from the experimental results by our numerical analysis. These results are discussed with respect to crucial advantages of the generically 3-dimensional tomography technique as compared to 2-dimensional methods. Our quantitative analysis of the 3d images demonstrates that in the case of our model composites the filler dispersion is good, independent on the filler concentration. Our new 3-dimensional results evidence that considering only 2-d pictures may lead to ambiguities that can lead to wrong conclusions. KW - X-ray tomography KW - Silica KW - Styrene butadiene rubber KW - Dispersion PY - 2012 DO - https://doi.org/10.1016/j.jnoncrysol.2011.10.009 SN - 0022-3093 VL - 358 IS - 3 SP - 557 EP - 563 PB - North-Holland Publ. Co. CY - Amsterdam AN - OPUS4-26105 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gärtner, Stefanie A1 - Carvalho, J.J. A1 - Emmerling, Franziska A1 - Garbe, L.-A. A1 - Schneider, Rudolf T1 - Polyclonal murine and rabbit antibodies for the bile acid isolithocholic acid N2 - Bile acids are relevant markers for clinical research. This study reports the production of antibodies for isolithocholic acid, the isomer of the extensively studied lithocholic acid. The IgG titer and affinity maturation were monitored during the immunizations of three mice and two rabbits. In both animal models, polyclonal antibodies with a high selectivity and affinity were produced. The development of a direct competitive ELISA with a test midpoint of 0.69 ± 0.05 µg/L and a measurement range from 0.09–15 µg/L is reported. Additionally, the crystal structure of isolithocholic acid is described for the first time. KW - ELISA KW - Crystal structure KW - Competitive assay KW - Immunization monitoring KW - 3ß-hydroxy-5ß-cholanic acid PY - 2015 DO - https://doi.org/10.1080/15321819.2014.924419 SN - 1532-1819 SN - 1532-4230 VL - 36 IS - 3 SP - 233 EP - 252 PB - Taylor & Francis CY - Philadelphia, Pa. AN - OPUS4-31836 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Devi, Sarita A1 - Goel, S. A1 - Rani, S. A1 - Schneider, Rudolf J. A1 - Rohilla, R. A1 - Kumari, Surbhi A1 - Prabhakar, N. T1 - MOF-metal nanohybrid-assisted charge transfer amplification for electrochemical biosensing of the MUC1 cancer biomarker N2 - Cancer is a severe disease characterized by high mortality and complex pathophysiology; however, its early and accurate diagnosis remains inadequate. Conventional diagnostic approaches often fall short, particularly for dense tissues, and are frequently invasive, costly, and of limited availability. This reinforces the need for a compact, economical, and ultrasensitive assay that is operationally simple and interpretable. We present an efficient electrochemical detection platform for the cancer biomarker mucin 1 (MUC1). A fluorine-doped tin oxide (FTO) surface was modified with an iron-based metal–organic framework (FeMOF) intercalated with palladium nanorods (PdNR). FeMOF was prepared using Fe3+/Fe2+ precursors at a 1.2/1 mmol ratio and dual ligands, i.e. tetrahydroxy-1,4-benzoquinone and 2-aminobenzene-1,4-dicarboxylic acid. AntiMUC1 antibodies were immobilized on a modified electrode via p-phenylenediamine (PDA) (FTO/FeMOF@PdNR/PDA/antiMUC1Ab) and evaluated using electrochemical impedance spectroscopy (EIS) and voltammetry. The designed sensor demonstrated an excellent binding affinity for the MUC1 antigen. Among these techniques, the EIS method stands out for its technical performance, as evidenced by the high sensitivity (detection limit 0.074 fg mL−1), quantification limit 0.24 fg mL−1, and high analytical sensitivity (1.39 × 103 Ω fg−1 mL−1 cm−2). The negligible cross-reactivity with interferent biomolecules, rapid response (10-minute equilibrium), regenerability up to 5 cycles, high reproducibility (RSD ∼1–3%), and long-term stability (up to 35 days) further validate the suitability of the proposed MUC1 immunosensor. This study presents an ultrasensitive biosensor that is compact, cost-effective, and easy for individuals at home to use after further development into a kit-based end product. Moreover, its excellent functionality for spiked serum samples shows promise for next-generation clinical diagnostics. KW - Antibodies KW - Metal-organic framework KW - Immunoassay PY - 2026 DO - https://doi.org/10.1039/D6AN00018E SP - 1 EP - 11 PB - Royal Society of Chemistry CY - London AN - OPUS4-65726 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Straub, D. A1 - Schneider, Ronald A1 - Bismut, E. A1 - Kim, H.-J. T1 - Reliability analysis of deteriorating structural systems N2 - Reliability analysis of deteriorating structural systems requires the solution of time-variant reliability problems. In the general case, both the capacity of and the loads on the structure vary with time. This analysis can be approached by approximation through a series of time-invariant reliability problems, which is a potentially effective strategy for cases where direct solutions of the time-variant reliability problem are challenging, e.g. for structural systems with many elements or arbitrary load processes. In this contribution, we thoroughly Review the formulation of the equivalent time-invariant reliability problems and extend this approximation to structures for which inspection and monitoring data is available. Thereafter, we present methods for efficiently evaluating the reliability over time. In particular, we propose the combination of sampling-based methods with a FORM (first-order reliability method) approximation of the series system reliability problem that arises in the computation of the lifetime reliability. The framework and algorithms are demonstrated on a set of numerical examples, which include the computation of the reliability conditional on inspection data. KW - Monitoring KW - Reliability KW - Deterioration KW - Structural systems KW - Bayesian analysis KW - Inspection PY - 2020 DO - https://doi.org/10.1016/j.strusafe.2019.101877 VL - 82 SP - Paper 101877, 1 PB - Elsevier Ltd. AN - OPUS4-48952 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gregório, Bruno J.R. A1 - Ramos, Inês I. A1 - Marques, Sara S. A1 - Barreiros, Luísa A1 - Magalhães, Luís M. A1 - Schneider, Rudolf A1 - Segundo, Marcela A. T1 - Microcarrier-based fluorescent yeast estrogen screen assay for fast determination of endocrine disrupting compounds N2 - The presence of endocrine-disrupting compounds (EDCs) in water poses a significant threat to human and animal health, as recognized by regulatory agencies throughout the world. The Yeast Estrogen Screen (YES) assay is an excellent method to evaluate the presence of these compounds in water due to its simplicity and capacity to assess the bioaccessible forms/fractions of these compounds. In the presence of a compound with estrogenic activity, Saccharomyces cerevisiae cells, containing a lacZ reporter gene encoding the enzyme β-galactosidase, are induced, the enzyme is synthesised, and released to the extracellular medium. In this work, a YES-based approach encompassing the use of a lacZ reporter gene modified strain of S. cerevisiae, microcarriers as solid support, and a fluorescent substrate, fluorescein di-β-D-galactopyranoside, is proposed, allowing for the assessment of EDCs’ presence after only 2 h of incubation. The proposed method provided an EC50 of 0.17 ± 0.03 nM and an LLOQ of 0.03 nM, expressed as 17β-estradiol. The assessment of different EDCs provided EC50 values between 0.16 and 1.2 × 103 nM. After application to wastewaters, similar results were obtained for EDCs screening, much faster, compared to the conventional 45 h spectrophotometric procedure using a commercial kit, showing potential for onsite high-throughput screening of environmental contamination. KW - Biosensoren KW - YES assay KW - Endokrine Disruptoren PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-602315 DO - https://doi.org/10.1016/j.talanta.2024.125665 VL - 271 SP - 1 EP - 7 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-60231 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pereira, P.M.R. A1 - Korsak, B. A1 - Sarmento, B. A1 - Schneider, Rudolf A1 - Fernandes, R. A1 - Tomé, J.P.C. T1 - Antibodies armed with photosensitizers: from chemical synthesis to photobiological applications N2 - Targeting photosensitizers to cancer cells by conjugating them with specific antibodies, able to recognize and bind to tumor-associated antigens, is today one of the most attractive strategies in photodynamic therapy (PDT). This comprehensive review updates on chemical routes available for the preparation of photo-immunoconjugates (PICs), which show dual chemical and biological functionalities: photo-properties of the photosensitizer and the immunoreactivity of the antibody. Moreover, photobiological results obtained with such photo-immunoconjugates using in vitro and in vivo cancer models are also discussed. KW - Therapeutische Antikörper KW - Krebstherapie KW - Photodynamische Therapie KW - Konjugate KW - Porphyrine KW - Phthalocyanine KW - Chlorine KW - Kopplungsmethoden PY - 2015 DO - https://doi.org/10.1039/c4ob02334j SN - 1477-0520 SN - 1477-0539 VL - 13 IS - 9 SP - 2518 EP - 2529 PB - RSC CY - Cambridge AN - OPUS4-32734 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kuhne, Maren A1 - Dippong, Martin A1 - Flemig, Sabine A1 - Hoffmann, Katrin A1 - Petsch, K. A1 - Schenk, J.A. A1 - Kunte, Hans-Jörg A1 - Schneider, Rudolf T1 - Comparative characterization of mAb producing hapten-specific hybridoma cells by flow cytometric analysis and ELISA N2 - A novel method that optimizes the screening for antibody-secreting hapten-specific hybridoma cells by using flow cytometry is described. Cell clones specific for five different haptens were analyzed. We selectively double stained and analyzed fixed hybridoma cells with fluorophore-labeled haptens to demonstrate the target-selectivity, and with a fluorophore-labeled anti-mouse IgG antibody to characterize the level of surface expression of membrane-bound IgGs. ELISA measurements with the supernatants of the individual hybridoma clones revealed that antibodies from those cells, which showed the highest fluorescence intensities in the flow cytometric analysis, also displayed the highest affinities for the target antigens. The fluorescence intensity of antibody-producing cells corresponded well with the produced antibodies' affinities toward their respective antigens. Immunohistochemical staining verified the successful double labeling of the cells. Our method makes it possible to perform a high-throughput screening for hybridoma cells, which have both an adequate IgG production rate and a high target affinity. KW - Immunization KW - Hapten KW - Monoclonal antibodies KW - Hybridoma KW - Flow cytometry KW - ELISA KW - Estradiol KW - Estrone KW - Digoxigenin KW - Zearalenone KW - Aflatoxin KW - CLSM PY - 2014 DO - https://doi.org/10.1016/j.jim.2014.07.004 SN - 0022-1759 SN - 1872-7905 VL - 413 SP - 45 EP - 56 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-32322 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kopineck, H.-J. A1 - Mundry, Eberhard A1 - Schneider, H. T1 - Zerstörungsfreie Materialprüfung in Gegenwart und Zukunft - 50 Jahre Deutsche Gesellschaft für Zerstörungsfreie Prüfung N2 - Die Darstellung der Arbeiten und Aufgaben der DGZfP und ihrer Mitglieder zeigt, daß sie sich auf die Förderung der in die Zukunft gerichteten Forschungs- und Entwicklungsschwerpunkte und auf Arbeiten für wirtschaftlich erfolgreiche Anwendungen konzentriert; intensiv ein Programm der Ausbildung und Qualifizierung von Prüfpersonal durchführt, das den Bedürfnissen aller Partner der Wirtschaft gerecht wird und das hoffentlich in den wichtigsten Teilen international gültig werden kann. Die DGZfP ist sich in ihren Bemühungen in Deutschland der Unterstützung durch alle wichtigen Behörden und Dienststellen sicher und setzt zudem Vertrauen in die ausländischen ZfP-Partner und in die Bereitschaft zur internationalen Zusammenarbeit. Unter Berücksichtigung dessen und des Bewußtseins der eigenen Möglichkeiten glaubt sie, daß sie den gesetzten Verpflichtungen gerecht werden kann, nämlich die zerstörungsfreien Prüfungen und Verfahren, richtig anzuwenden, Aussagen und Folgerungen durch Forschung, Entwicklung, Anwendung und Ausbildung zu intensivieren und zu unterstützen. Die zerstörungsfreie Materialprüfung der Gegenwart und Zukunft wird von zwei menschlichen Eckpfeilern bestimmt: Einmal von den Menschen, die auf der Basis solider Fachkenntnisse die Materialprüfung erfolgreich durchführen, und zum anderen von den Menschen, die als Forscher, Ingenieure und Techniker sich den Anforderungen für Forschung und praxisbezogene Anwendung stellen, die ideenreich Geräte, Anlagen und Verfahren konzipieren und realisieren, mit denen Prüfanforderungen vielfältiger Art erfüllt werden können. Beide Gruppen müssen die gegenseitigen nationalen und internationalen Kontakte pflegen und intensivieren. PY - 1983 SN - 0025-5300 VL - 25 IS - 4 SP - 101 EP - 104 PB - Hanser CY - München AN - OPUS4-40454 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Witke, Klaus A1 - Klaffke, Dieter A1 - Schneider, Thomas A1 - Schreckenbach, J.P. T1 - Laser-damaging as a useful tool for materials characterization by Raman microscopy KW - Raman-Mikroskopie KW - Raman-Laser KW - Laserstrahlbearbeitung PY - 1999 SN - 0169-4332 SN - 1873-5584 VL - 151 IS - 1-2 SP - 33 EP - 39 PB - North-Holland CY - Amsterdam AN - OPUS4-709 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schneider, Ralf A1 - Weigert, Florian A1 - Lesnyak, V. A1 - Leubner, S. A1 - Lorenz, T. A1 - Behnke, Thomas A1 - Dubavik, A. A1 - Joswig, J.-O. A1 - Resch-Genger, Ute A1 - Gaponik, N. A1 - Eychmüller, A. ED - Resch-Genger, Ute ED - Schneider, Ralf T1 - pH and concentration dependence of the optical properties of thiol-capped CdTe nanocrystals in water and D2O N2 - The optical properties of semiconductor nanocrystals (SC NCs) are largely controlled by their size and surface chemistry, i.e., the chemical composition and thickness of inorganic passivation shells and the chemical nature and number of surface ligands as well as the strength of their bonds to surface atoms. The latter is particularly important for CdTe NCs, which – together with alloyed CdₓHg₁₋ₓTe – are the only SC NCs that can be prepared in water in high quality without the need for an additional inorganic passivation shell. Aiming at a better understanding of the role of stabilizing ligands for the control of the application-relevant fluorescence features of SC NCs, we assessed the influence of two of the most commonly used monodentate thiol ligands, thioglycolic acid (TGA) and mercaptopropionic acid (MPA), on the colloidal stability, photoluminescence (PL) quantum yield (QY), and PL decay behavior of a set of CdTe NC colloids. As an indirect measure for the strength of the coordinative bond of the ligands to SC NC surface atoms, the influence of the pH (pD) and the concentration on the PL properties of these colloids was examined in water and D₂O and compared to the results from previous dilution studies with a set of thiol-capped Cd₁₋ₓHgₓTe SC NCs in D₂O. As a prerequisite for these studies, the number of surface ligands was determined photometrically at different steps of purification after SC NC synthesis with Ellman’s test. Our results demonstrate ligand control of the pH-dependent PL of these SC NCs, with MPA-stabilized CdTe NCs being less prone to luminescence quenching than TGA-capped ones. For both types of CdTe colloids, ligand desorption is more pronounced in H₂O compared to D₂O, underlining also the role of hydrogen bonding and solvent molecules. KW - Quantum dots KW - Fluorescence KW - Ligand analysis KW - Nano particles PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-371253 DO - https://doi.org/10.1039/c6cp03123d VL - 18 IS - 28 SP - 19083 EP - 19092 PB - RSC CY - Cambridge AN - OPUS4-37125 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Duwe, M. A1 - Quast, J.-H. A1 - Schneider, S. A1 - Fischer, Daniel A1 - Beck, Uwe T1 - Thin-film metrology of tilted and curved surfaces by imaging Mueller-matrix ellipsometry N2 - For the vast majority of ellipsometric measurements, the application of planar substrates is mandatory and requires a proper sample alignment prior to the measurement. Here, the authors present a generalized approach of how to extract the isotropic ellipsometric sample parameters from an imaging Mueller-matrix measurement even if the sample is significantly misaligned. They validate the method by layer-thickness calculations based on imaging Mueller-matrix measurements of flat crystalline silicon samples that were misaligned on purpose. Furthermore, they also exploit this method’s capabilities to perform spatially resolved layer-thickness measurements of a single-layer indium-tin-oxide coating on a fused-silica microlens without the need of realignment or repositioning of the sample during the measurement. T2 - 8th International conference on spectroscopic ellipsometry (ICSE-8) CY - Barcelona, Spain DA - 26.05.2019 KW - Metrology KW - Thin films KW - Polarization spectroscopy KW - Spectroskopic Imaging KW - Mueller-Matrix imaging ellipsometry PY - 2019 DO - https://doi.org/10.1116/1.5122757 SN - 2166-2746 SN - 2327-9877 VL - 37 IS - 6 SP - 062908 PB - AIP CY - New York, NY AN - OPUS4-50209 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fischer, Daniel A1 - Griepentrog, Michael A1 - Beck, Uwe A1 - Duwe, M. A1 - Quast, J.-H. A1 - Schneider, S. T1 - Effect of curvature of spherical microscopic indentations on the ellipsometric readout N2 - The authors describe and interpret curvature-related changes to the ellipsometric readout. As model system for a concave curvature, a set of three spherical microscopic indents in silicon (100) of different sizes was prepared by instrumented indentation testing using a spherical indenter. For reference, these samples were characterized by AFM to reveal the topography of each structure. The concavelike indents were analyzed by Mueller-Matrix imaging ellipsometry to extract lateral intensity images of 12 elements of the Mueller-Matrix. As a result of the detailed analysis of the image elements m22, m23, and m14, it was possible to correlate intensity changes and symmetry properties to depolarization and cross polarization induced by the edge threshold and the curved surface of the indent. KW - Spectroskopic Imaging KW - Mueller-Matrix imaging ellipsometry KW - Structural anomalies KW - Structural inhomogenities PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-498105 DO - https://doi.org/10.1116/1.5122252 VL - 37 IS - 6 SP - 062906-1 EP - 062906-5 PB - American Vacuum Society AN - OPUS4-49810 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carvalho, José Joao A1 - Walter, Astrid A1 - Baermann, Yvonne A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schenk, J.A. A1 - Schneider, Rudolf T1 - Non-invasive monitoring of immunization progress in mice via IgG from feces N2 - A non-invasive method to monitor the humoral immune response in mice after immunization is described. From fecal pellets of an individual mouse, a sufficient amount of active immunoglobulins or their fragments can be extracted to perform a regular examination of the status of the immune response by immunoassay. Hapten-specific antibodies from the feces of mice from three immunization trials showed very similar characteristics to those obtained from serum at a given date. Therefore, it can be suspected that some serum IgG enters the intestinal lumen and ends up in the feces, where they appear to be considerably stable. Hapten-specific IgAs were not found in the feces. Being able to analyze antibody titers in feces could be an interesting animal welfare refinement to standard practice that does not entail repeated blood sampling. KW - Immunization monitoring KW - IgG KW - Coproantibodies KW - Feces KW - Animal welfare KW - 3R concept PY - 2012 UR - http://iv.iiarjournals.org/content/26/1/63.full.pdf+html SN - 0258-851x VL - 26 IS - 1 SP - 63 EP - 70 PB - In vivo CY - Athens AN - OPUS4-25283 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -