TY - JOUR A1 - Titscher, Thomas A1 - Unger, Jörg F. A1 - Oliver, J. T1 - Implicit explicit integration of gradient enhanced damage models N2 - Quasi-brittle materials exhibit strain softening. Their modeling requires regularized constitutive formulations to avoid instabilities on the material level. A commonly used model is the implicit gradient-enhanced damage model. For complex geometries, it still Shows structural instabilities when integrated with classical backward Euler schemes. An alternative is the implicit–explicit (IMPL-EX) Integration scheme. It consists of the extrapolation of internal variables followed by an implicit calculation of the solution fields. The solution procedure for the nonlinear gradient-enhanced damage model is thus transformed into a sequence of problems that are algorithmically linear in every time step. Therefore, they require one single Newton–Raphson iteration per time step to converge. This provides both additional robustness and computational acceleration. The introduced extrapolation error is controlled by adaptive time-stepping schemes. This paper introduced and assessed two novel classes of error control schemes that provide further Performance improvements. In a three-dimensional compression test for a mesoscale model of concrete, the presented scheme was about 40 times faster than an adaptive backward Euler time integration. KW - Implicit explicit schemes KW - Gradient-enhanced damage model KW - Adaptive time stepping KW - Continuum damage KW - Robustness PY - 2019 DO - https://doi.org/10.1061/(ASCE)EM.1943-7889.0001608 SN - 0733-9399 SN - 1943-7889 VL - 145 IS - 7 SP - 04019040-1 EP - 04019040-13 PB - ASCE - American Society of Civil Engineers AN - OPUS4-48361 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - De Samber, B. A1 - Scharf, Oliver A1 - Buzanich, Günter A1 - Garrevoet, J. A1 - Tack, P. A1 - Radtke, Martin A1 - Riesemeier, Heinrich A1 - Reinholz, Uwe A1 - Evens, R. A1 - De Schamphelaere, K. A1 - Falkenberg, G. A1 - Janssen, C. A1 - Vincze, L. T1 - Three-dimensional X-ray fluorescence imaging modes for biological specimens using a full-field energy dispersive CCD camera N2 - Besides conventional scanning X-ray fluorescence imaging at synchrotron sources, full-field X-ray fluorescence (FF-XRF) imaging techniques that do not implicitly require spatial scanning of the sample have become available. FF-XRF has become achievable thanks to the development of a new type of energy dispersive CCD-based 2D detector, also referred to as a 'color X-ray camera (CXC)' or 'SLcam'. We report on different imaging schemes for biological samples using FF-XRF imaging: (a) 2D 'zoom' imaging with pinhole optics using the 'camera obscura' principle; (b) 2D 'fixed magnification' imaging using magnifying polycapillary optics; and (c) 3D-FF-XRF imaging using an X-ray sheet beam or computed tomography (CT). The different FF-XRF imaging modes are illustrated using the crustacean Daphnia magna, a model organism for investigating the effects of metals on organism/ecosystem health, and foraminifera, a class of amoeboid protist. Detailed analytical characterization of the set-up is performed through analyzing various reference materials in order to determine limits of detection (LODs) and sensitivities. Experiments were performed using the BAMline at the BESSY synchrotron (Berlin, Germany) and using the P06 Hard X-ray Microprobe at the PETRAIII synchrotron (Hamburg, Germany). KW - CXC KW - BAMline KW - Maia detector KW - Synchrotron PY - 2019 DO - https://doi.org/10.1039/c9ja00198k VL - 34 IS - 10 SP - 2083 EP - 2093 PB - Royal Society of Chemistry CY - Cambridge, United Kingdom AN - OPUS4-49359 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -