TY - JOUR A1 - Walther, M. A1 - Jung, C. M. A1 - Bergmann, R. A1 - Pietzsch, J. A1 - Rode, K. A1 - Fahmy, K. A1 - Mirtschink, P. A1 - Stehr, S. A1 - Heintz, A. A1 - Wunderlich, G. A1 - Kraus, Werner A1 - Pietzsch, H.-J. A1 - Kropp, J. A1 - Deussen, A. A1 - Spies, H. T1 - Synthesis and Biological Evaluation of a New Type of 99mTechnetium-Labeled Fatty Acid for Myocardial Metabolism Imaging PY - 2007 SN - 1043-1802 SN - 1520-4812 VL - 18 SP - 216 EP - 230 CY - Washington, DC AN - OPUS4-14514 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zeleny, R. A1 - Voorspoels, S. A1 - Ricci, M. A1 - Becker, Roland A1 - Jung, Christian A1 - Bremser, Wolfram A1 - Sittidech, M. A1 - Panyawathanakit, N. A1 - Wong, W. F. A1 - Choi, S.M. A1 - Lo, K.C. A1 - Yeung, W. Y. A1 - Kim, D.H. A1 - Han, J. A1 - Ryu, J. A1 - Mingwu, S. A1 - Chao, W. A1 - Schantz, M.M. A1 - Lippa, K.A. A1 - Matsuyama, S. T1 - Evaluation of the state-of-the-art measurement capabilities for selected PBDEs and decaBB in plastic by the international intercomparison CCQM-P114 N2 - An international intercomparison involving eight national metrology institutes (NMIs) was conducted to establish their current measurement capabilities for determining five selected congeners from the brominated flame retardant classes polybrominated diphenyl ethers and polybrominated biphenyls. A candidate reference material consisting of polypropylene fortified with technical mixtures of penta-, octa- and decabromo diphenyl ether and decabromo biphenyl, which was thoroughly assessed for material homogeneity and stability, was used as study material. The analytical procedures applied by the participants differed with regard to sample pre-treatment, extraction, clean-up, employed calibrants and type of calibration procedure as well as regarding analytical methods used for separation, identification and quantification of the flame retardant congeners (gas chromatography coupled to an electron capture detector (GC-ECD), gas chromatography-mass spectrometry in the electron ionisation mode (GC-EI-MS), gas chromatography-mass spectrometry in the electron capture negative ionisation mode (GC-ECNI-MS), and liquid chromatography-inductive coupled plasma-mass spectrometry (LC-ICP-MS)). The laboratory means agreed well with relative standard deviations of the mean of means of 1.9%, 4.8%, 5.5% and 5.4% for brominated diphenyl ether (BDE) 47, 183 and 209 and for the brominated biphenyl (BB) congener 209, respectively. For BDE 206, a relative standard deviation of 28.5% was obtained. For all five congeners, within-laboratory relative standard deviations of six measurements obtained under intermediate precision conditions were between 1% and 10%, and reported expanded measurements uncertainties typically ranged from 4% to 10% (8% to 14% for BDE 206). Furthermore, the results are in good agreement with those obtained in the characterization exercise for determining certified values for the flame retardant congeners in the same material. The results demonstrate the state-of-the-art measurement capabilities of NMIs for quantifying representative BDE congeners and BB 209 in a polymer. The outcome of this intercomparison (pilot study) in conjunction with possible improvements for employing exclusively calibrants with thoroughly assessed purity suggests that a key comparison aiming at underpinning calibration and measurement capability (CMC) claims of NMIs can be conducted. KW - Flame retardants KW - Polymer KW - Polybrominated diphenyl ethers (PBDEs) KW - Polybrominated biphenyls (PBBs) KW - International intercomparison PY - 2010 DO - https://doi.org/10.1007/s00216-009-3314-7 SN - 1618-2642 SN - 1618-2650 VL - 396 IS - 4 SP - 1501 EP - 1511 PB - Springer CY - Berlin AN - OPUS4-22905 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Batatia, Ilyes A1 - Benner, Philipp A1 - Chiang, Yuan A1 - Elena, Alin M. A1 - Kovács, Dávid P. A1 - Riebesell, Janosh A1 - Advincula, Xavier R. A1 - Asta, Mark A1 - Avaylon, Matthew A1 - Baldwin, William J. A1 - Berger, Fabian A1 - Bernstein, Noam A1 - Bhowmik, Arghya A1 - Bigi, Filippo A1 - Blau, Samuel M. A1 - Cărare, Vlad A1 - Ceriotti, Michele A1 - Chong, Sanggyu A1 - Darby, James P. A1 - De, Sandip A1 - Della Pia, Flaviano A1 - Deringer, Volker L. A1 - Elijošius, Rokas A1 - El-Machachi, Zakariya A1 - Fako, Edvin A1 - Falcioni, Fabio A1 - Ferrari, Andrea C. A1 - Gardner, John L. A. A1 - Gawkowski, Mikołaj J. A1 - Genreith-Schriever, Annalena A1 - George, Janine A1 - Goodall, Rhys E. A. A1 - Grandel, Jonas A1 - Grey, Clare P. A1 - Grigorev, Petr A1 - Han, Shuang A1 - Handley, Will A1 - Heenen, Hendrik H. A1 - Hermansson, Kersti A1 - Ho, Cheuk Hin A1 - Hofmann, Stephan A1 - Holm, Christian A1 - Jaafar, Jad A1 - Jakob, Konstantin S. A1 - Jung, Hyunwook A1 - Kapil, Venkat A1 - Kaplan, Aaron D. A1 - Karimitari, Nima A1 - Naik, Aakash A. A1 - Csányi, Gábor T1 - A foundation model for atomistic materials chemistry N2 - Atomistic simulations of matter, especially those that leverage first-principles (ab initio) electronic structure theory, provide a microscopic view of the world, underpinning much of our understanding of chemistry and materials science. Over the last decade or so, machine-learned force fields have transformed atomistic modeling by enabling simulations of ab initio quality over unprecedented time and length scales. However, early machine-learning (ML) force fields have largely been limited by (i) the substantial computational and human effort required to develop and validate potentials for each particular system of interest and (ii) a general lack of transferability from one chemical system to the next. Here, we show that it is possible to create a general-purpose atomistic ML model, trained on a public dataset of moderate size, that is capable of running stable molecular dynamics for a wide range of molecules and materials. We demonstrate the power of the MACE-MP-0 model—and its qualitative and at times quantitative accuracy—on a diverse set of problems in the physical sciences, including properties of solids, liquids, gases, chemical reactions, interfaces, and even the dynamics of a small protein. The model can be applied out of the box as a starting or “foundation” model for any atomistic system of interest and, when desired, can be fine-tuned on just a handful of application-specific data points to reach ab initio accuracy. Establishing that a stable force-field model can cover almost all materials changes atomistic modeling in a fundamental way: experienced users obtain reliable results much faster, and beginners face a lower barrier to entry. Foundation models thus represent a step toward democratizing the revolution in atomic-scale modeling that has been brought about by ML force fields. KW - Materials Design KW - Thermal Conducitivity KW - Nanoparticles KW - Batteries PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-647829 DO - https://doi.org/10.1063/5.0297006 SN - 0021-9606 VL - 163 IS - 18 SP - 1 EP - 89 PB - AIP Publishing AN - OPUS4-64782 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Jung, C. M. A1 - Kraus, Werner A1 - Leibnitz, Peter A1 - Pietzsch, H.-J. A1 - Kropp, J. A1 - Spies, H. T1 - Synthesis and First Crystal Structure of Rhenium Complexes derived from omega-Functionalized Fatty Acids as Model Compounds of Technetium Tracers for Myocardial Metabolism Imaging N2 - In an attempt to develop new technetium-based radiopharmaceuticals for the noninvasive diagnosis of myocardial metabolism, we have synthesized three examples of novel metal-containing fatty acid derivatives according to the 3+1 mixed-ligand and the Schiff base/tricarbonyl design. The chelates contain the metal core in the oxidation states +5 and +1, respectively, and are attached to the end-position of a fatty acid chain. The complex formation was accomplished by ligand-exchange reactions with three different rhenium precursors, whereas the inactive rhenium metal was utilized as a surrogate of the technetium radionuclide. The molecular structures of the fatty acid complexes 7, 10 and 14 were determined by single-crystal X-ray diffraction analyses and impressively show a general problem in technetium tracer research, namely the significant structural alterations of bioactive molecules by coordination even to small metal chelates. KW - Rhenium KW - Technetium KW - Fatty acids KW - Drug research KW - Radiopharmaceuticals PY - 2002 DO - https://doi.org/10.1002/1099-0682(200205)2002:5<1219::AID-EJIC1219>3.0.CO;2-N SN - 1434-1948 SN - 1099-0682 VL - 2002 IS - 5 SP - 1219 EP - 1225 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-1552 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Jung, C. M. A1 - Heintz, A. A1 - Kraus, Werner A1 - Wunderlich, G. A1 - Leibnitz, Peter A1 - Pietzsch, H.-J. A1 - Kropp, J. A1 - Deussen, A. A1 - Spies, H. ED - Marino, N. T1 - Technetium- and Rhenium-Labelled Fatty Acids as Model Compounds for Myocardial Metabolism Imaging N2 - In an attempt to develop new technetium-based radiopharmaceuticals for the non-invasive diagnosis of oxidative myocardial metabolism, rhenium model compounds according to the ‚3+1' mixed ligand approach as well as the organometallic tricarbonyl-design were synthesized. The geometrical impact of different chelates on the integrity of the fatty acid head structure was determined by single crystal X-ray analyses. To evaluate the diagnostic potential of the analogous Technetium-99m compounds, fatty acid complexes of the ‚3+1' mixed ligand type were prepared on n.c.a.-level and studied in the isolated constant-flow-perfused guinea pig heart model; compared to established [123I]Iodine-labelled fatty acid radiotracers, the tested Technetium-99m derivatives showed a specific, however significantly lower myocardial extraction rate. T2 - 6th International Symposium on Technetium in Chemistry and Nuclear Medicine CY - Bressanone, Italy DA - 2002-09-04 KW - Fatty acids KW - Metabolism KW - Myocardial Imaging KW - Rhenium KW - Technetium-99m PY - 2002 UR - http://www.fzd.de/db/!Publications?pSelYear=2002&pLang=en&pNid=0&pSelWithSubmitted=0&pSelSort=TITEL&pSelPublForm=4&pSelPage=2 SN - 88-86281-73-0 N1 - Serientitel: Technetium, rhenium and other metals in chemistry and nuclear medicine – Series title: Technetium, rhenium and other metals in chemistry and nuclear medicine VL - 6 IS - 6 SP - 443 EP - 445 PB - SGEditoriali CY - Padova AN - OPUS4-1999 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zhou, Z. A1 - Han, Q. A1 - Wang, D. A1 - Macé, T. A1 - Kipphardt, Heinrich A1 - Maiwald, Michael A1 - Tuma, Dirk A1 - Uehara, S. A1 - Akima, D. A1 - Shimosaka, T. A1 - Jung, J. A1 - Oh, S.-H. A1 - van der Veen, A. A1 - van Wijk, J.I.T. A1 - Ziel, P. R. A1 - Konopelko, L. A1 - Valkova, M. A1 - Mogale, D.M. A1 - Botha, A. A1 - Brewer, P. A1 - Murugan, A. A1 - Minnaro, M.D. A1 - Miller, M. A1 - Guenther, F. A1 - Kelly, M.E. T1 - CCQM K101 Final report international comparison CCQM-K101:Oxygen in nitrogen-a track B comparison and that the matrix contains argon N2 - This key comparison aims to assess the capabilities of the participants to determine the amount-of-substance fraction oxygen in nitrogen. The GAWG has classified this as a track B comparison, due to the unexpected 50 μmol/mol argon mole fraction content of the transfer standards, which effects the achievable performance of some measurement techniques such a GC-TCD. The separation of oxygen and argon is challenging, and not all systems in use are equally well designed for it. As this analytical challenge due to a substantial fraction of argon in the transfer standards became a reality, the Gas Analysis Working Group (GAWG) decided to qualify this key comparison as a regular key comparison and not as a core comparison, which may be used to support calibration and measurement capabilities (CMCs) for oxygen in nitrogen, or for oxygen in nitrogen mixtures containing argon only (see also the section on support to CMCs). KW - CCQM-K101 KW - Gas analysis PY - 2016 UR - http://iopscience.iop.org/article/10.1088/0026-1394/53/1A/08013 SN - 1681-7575 SN - 0026-1394 VL - 53 IS - Techn Suppl SP - 08013, 1 EP - 71 PB - IOP publishing AN - OPUS4-40013 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kästner, L. A1 - Ahmadi, Samim A1 - Jonietz, Florian A1 - Jung, P. A1 - Caire, G. A1 - Ziegler, Mathias A1 - Lambrecht, J. T1 - Classification of Spot-Welded Joints in Laser Thermography Data Using Convolutional Neural Networks N2 - Spot welding is a crucial process step in various industries. However, classification of spot welding quality is still a tedious process due to the complexity and sensitivity of the test material, which drain conventional approaches to its limits. In this article, we propose an approach for quality inspection of spot weldings using images from laser thermography data. We propose data preparation approaches based on the underlying physics of spot-welded joints, heated with pulsed laser thermography by analyzing the intensity over time and derive dedicated data filters to generate training datasets. Subsequently, we utilize convolutional neural networks to classify weld quality and compare the performance of different models against each other. We achieve competitive results in terms of classifying the different welding quality classes compared to traditional approaches, reaching an accuracy of more than 95 percent. Finally, we explore the effect of different augmentation methods. KW - Active thermal imaging KW - Laser thermography KW - Spot-welded joints KW - Convolutional neural network KW - Classification KW - Data processing PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-524216 DO - https://doi.org/10.1109/ACCESS.2021.3063672 VL - 9 SP - 48303 EP - 48312 AN - OPUS4-52421 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hauffen, J. C. A1 - Kästner, L. A1 - Ahmadi, Samim A1 - Jung, P. A1 - Caire, G. A1 - Ziegler, Mathias T1 - Learned block iterative shrinkage thresholding algorithm for photothermal super resolution imaging N2 - Block-sparse regularization is already well known in active thermal imaging and is used for multiple-measurement-based inverse problems. The main bottleneck of this method is the choice of regularization parameters which differs for each experiment. We show the benefits of using a learned block iterative shrinkage thresholding algorithm (LBISTA) that is able to learn the choice of regularization parameters, without the need to manually select them. In addition, LBISTA enables the determination of a suitable weight matrix to solve the underlying inverse problem. Therefore, in this paper we present LBISTA and compare it with state-of-the-art block iterative shrinkage thresholding using synthetically generated and experimental test data from active thermography for defect reconstruction. Our results show that the use of the learned block-sparse optimization approach provides smaller normalized mean square errors for a small fixed number of iterations. Thus, this allows us to improve the convergence speed and only needs a few iterations to generate accurate defect reconstruction in photothermal super-resolution imaging. KW - Thermography KW - Laser KW - Machine learning KW - Optimization KW - Non-destructive testing KW - NDT KW - Neural network KW - Defect reconstruction KW - Block-sparsity KW - Active thermal imaging KW - Regularization KW - Laser thermography PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-554598 DO - https://doi.org/10.3390/s22155533 SN - 1424-8220 VL - 22 IS - 15 SP - 1 EP - 15 PB - MDPI CY - Basel AN - OPUS4-55459 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schallschmidt, Kristin A1 - Becker, Roland A1 - Jung, Christian A1 - Bremser, Wolfram A1 - Nehls, Irene A1 - Leschber, G. A1 - Frese, S. A1 - Walles, T. A1 - Neudecker, J. T1 - Comparison of volatile organic compounds from lung cancer patients and healthy controls—challenges and limitations of an observational study N2 - The design and operation of an observational study on the profiles of volatile organic compounds (VOC) in the breath of 37 lung cancer patients and 23 healthy controls of similar age is outlined. The necessity to quantify each VOC considered as potential disease marker on basis of individual calibration is elaborated and the quality control measures required to maintain reproducibility in breath sampling and subsequent instrumental trace VOC analysis using SPME-GC-MS over a study period of 14 months are described. 24 VOC were quantified on basis of their previously suggested potential as cancer markers. The breath concentration levels of aromatic compounds was expectedly increased in smokers while lung cancer patients displayed significantly increased levels of oxygenated VOC such as aldehydes, 2-butanone and 1-butanol. Though sets of selected oxygenated VOC displayed sensitivities and specificities between 80 and 90% using linear discriminant analysis with leave-one-out cross validation the effective selectivity of the breath VOC approach with regard to cancer detection is clearly limited. Results were discussed against the background of the literature on volatile cancer marker investigations and the prospects to link increased VOC levels in patients’ breath with approaches to employ sniffer dogs. Experiences from this study and the literature suggest that the current state of breath VOC based discrimination between cancer patients and healthy controls is hardly improvable. Observational studies tend to observe significant differences mostly in levels of certain oxygenated VOC but without resolution required for practical application. Any step towards practicable exploitation of VOC profile differences for illness detection would have to solve current restrictions set by the low and variable VOC concentrations. Further challenges are the technical complexity of studies involving breath sampling and possibly the limited capability of current analytical procedures to detect instable marker candidates. KW - Breath KW - Volatile organic compounds KW - Marker KW - Cancer KW - Gas chromatography KW - Solid phase microextraction KW - Volatilome PY - 2016 DO - https://doi.org/10.1088/1752-7155/10/4/046007 SN - 1752-7155 SN - 1752-7163 VL - 10 IS - 4 SP - Article 046007, 1 EP - 17 PB - IOP Publishing AN - OPUS4-37801 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Augustin, Sven A1 - Hieronymus, J. A1 - Jung, P. A1 - Hübers, H.-W. T1 - Compressed sensing in a fully non-mechanical 350 GHz imaging setting N2 - We investigate a single-pixel camera (SPC) that relies on non-mechanical scanning with a terahertz (THz) spatial light modulator (SLM) and Compressed Sensing (CS) for image generation. The camera is based on a 350 GHz multiplier source and a Golay cell detector. The SLM consists of a Germanium disc, which is illuminated by a halogen lamp. The light of the lamp is transmitted through a thin-film transistor (TFT) liquid crystal display (LCD). This enables the generation of light patterns on the Germanium disc, which in turn produce reflecting patterns for THz radiation. Using up to 1000 different patterns the pseudo-inverse reconstruction algorithm and the CS algorithm CoSaMP are evaluated with respect to image quality. It is shown that CS allows a reduction of the necessary measurements by a factor of three without compromising the image quality. KW - Compressed Sensing (CS) KW - Terahertz KW - Imaging KW - Single-pixel camera KW - Non-mechanical scanning KW - TFT-LCD KW - THz KW - Spatial light modulator PY - 2015 DO - https://doi.org/10.1007/s10762-014-0141-5 SN - 1866-6892 SN - 1866-6906 VL - 36 IS - 5 SP - 496 EP - 512 PB - Springer CY - New York, NY AN - OPUS4-33022 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schallschmidt, Kristin A1 - Becker, Roland A1 - Jung, Christian A1 - Rolff, J. A1 - Fichtner, I. T1 - Investigation of cell culture volatilomes using solid phase micro extraction: options and pitfalls exemplified with adenocarcinoma cell lines N2 - Three strategies to sample volatile organic compounds (VOC) from lung cancer cell lines cultured in vitro were compared. Headspace solid phase microextraction was applied in situ to culture flasks and alternatively to subsamples of headspace gas or to nutrient solution subsamples followed by gas chromatography–mass spectrometry. The direct quantification of 55 VOC in the headspace of cell cultures was validated and is discussed with respect to reproducibility and system-related interferences. The role of the VOC background from culture media and usually employed polystyrene culture vessels is examined and was seen to invoke potentially misleading conclusions. The commercial A549 and two further adenocarcinoma cell lines displayed largely similar VOC profiles with distinct differences regarding certain individual substances. There is evidence for the inappropriateness of the standard cell culturing methods in the search for volatile cancer markers. KW - A549 KW - Lung cancer cell culture KW - GC–MS KW - SPME KW - VOC KW - Volatilome KW - Alcohol marker KW - Micropulverization KW - HPLC-MS/MS KW - Fortification KW - Long term stability PY - 2015 DO - https://doi.org/10.1016/j.jchromb.2015.10.004 SN - 0378-4347 SN - 1570-0232 SN - 1387-2273 SN - 1873-376X VL - 1006 SP - 158 EP - 166 PB - Elsevier B.V. CY - Amsterdam [u.a.] AN - OPUS4-34991 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schulze, M. A1 - Neugebauer, M. A1 - Meeß, R. A1 - Brzoska, J. A1 - Jung, A. A1 - Staude, Andreas A1 - Ehrig, Karsten T1 - Der Einfluss unterschiedlicher Materialzusammensetzungen auf das dimensionelle Messen von Mikroobjekten mittels Mikro-Computertomographie N2 - Computertomographische Aufnahmen von Objekten mit stark voneinander abweichenden Absorptionseigenschaften stellen sowohl für den Anwendungsbereich der zerstörungsfreien Prüfung als auch für den der dimensionellen Messtechnik eine besondere Herausforderung dar. Die Aufnahmekonfiguration kann bei Objekten dieser Art häufig nicht so gewählt werden, dass die unterschiedlichen Materialeigenschaften mit ausreichender Qualität abgebildet werden können. Aus diesem Grund ist eine objektive Bewertung der Oberflächenmessung mit Hilfe eines in dieser Untersuchung eingeführten Qualitätsmaßes erforderlich. Anhand der in dieser Arbeit vorgestellten Prüfkörperserie soll der Einfluss der Materialzusammensetzung auf das dimensionelle Messen mit CT erfasst und charakterisiert werden. Unter Berücksichtigung der Qualitätsbewertung der Oberflächenpunkte erfolgt die Berechnung der Form- und Abstandsabweichungen. Ziel ist es, die Genauigkeit der Oberflächenmessung hinsichtlich unterschiedlicher Aufnahmeparameter und Materialzusammensetzungen darzustellen. Anhand dieser Ergebnisse ist es möglich, den computertomographischen Aufnahme- und Auswertungsprozess quantitativ zu bewerten und Ursachen der Abweichungen zu diskutieren. T2 - DGZfP-Jahrestagung 2010 CY - Erfurt, Deutschland DA - 2010-05-10 PY - 2010 UR - http://www.ndt.net/article/dgzfp2010/Inhalt/di2a4.pdf SN - 978-3-940283-26-9 IS - DGZfP-BB 122 (Di.2.A.4) SP - 1 EP - 9 CY - Berlin AN - OPUS4-22528 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schubnell, J. A1 - Konidena, S. K. A1 - Jung, M. A1 - Braun, M. A1 - Ehlers, S. A1 - Madia, Mauro A1 - Kannengießer, Thomas A1 - Löschner, D. T1 - Approach for the probabilistic fatigue assessment of welded joints based on the local geometry of the weld seam N2 - Welded joints show large variation of the weld toe geometry along the weld seam, which is one important reason for the comparably large scatter in fatigue life. Therefore, it is crucial to take the local geometry at the weld toe into account, to reduce the conservatism in fatigue assessment of welded joints. This study is based on the IBESS procedure for the calculation of the fatigue strength, whereby the evaluation of local geometrical parameters is carried out by means of 3D surface scans. The approach is validated against 26 fatigue test series. The fatigue life is in general overpredicted, whereas good agreement is achieved for high stress ratio (R = 0.5). A sensitivity analysis conducted with IBESS shows that weld toe radii ρ < 2 mm and flank angle α < 30° have a significant influence on the calculated fatigue strength. In contrast to this, no strong correlation between ρ and the fatigue strength was determined experimentally in this study. KW - 3D Scanning KW - Fatigue Strength KW - Fracture Mechanics KW - IBESS Approach KW - Local Weld Geometry KW - Welded Joints PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-585700 DO - https://doi.org/10.1111/ffe.14170 SN - 8756-758X SP - 1 EP - 20 PB - Wiley AN - OPUS4-58570 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Park, J. A1 - Kim, G. B. A1 - Lippitz, Andreas A1 - Kim, Y. M. A1 - Jung, D. A1 - Unger, Wolfgang A1 - Kim, Y.-P. A1 - Lee, T. G. T1 - Plasma-polymerized antifouling biochips for label-free measurement of protease activity in cell culture media N2 - We report polyethylene glycol (PEG)-grafting antifouling surfaces using a plasma copolymerized (PcP) technique to monitor protease activity in complex media. By varying the mixing ratio of the PEG and ethylenediamine (EDA) precursors, the PcP-PEG-EDA (PcP-PE) film was able to easily control surface amine density with good preservation of the internal PEG structure. We found that nonspecific protein adsorption was dramatically reduced in serum-containing media on the PcP-PE films, as opposed to that on plasma polymerized-EDA (PP-E) films without PEG. When SPR sensor chips coated with PcP-PE film were employed to detect protease activity, biotinylated luciferase probes (luciferase-peptide-biotin) on streptavidin-conjugated SPR chips enabled real-time and label-free measurement of matrix metalloproteinase activity in cell culture media. Owing to its excellent antifouling ability, this newly developed method boasts minimal nonspecific binding and can serve as a biochip platform to promote a wide range of applications in the biological field. KW - Polyethylene glycol (PEG)-grafting antifouling surface KW - Biochip KW - ATR-FTIR spectroscopy KW - XPS KW - NEXAFS KW - Plasma PY - 2019 DO - https://doi.org/10.1016/j.snb.2018.10.123 SN - 0925-4005 VL - 281 SP - 527 EP - 534 PB - Elsevier B.V. AN - OPUS4-46463 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tisato, F. A1 - Refosco, F. A1 - Porchia, M. A1 - Bolzati, C. A1 - Bandoli, G. A1 - Dolmella, A. A1 - Duatti, A. A1 - Boschi, A. A1 - Jung, C. M. A1 - Pietzsch, H.-J. A1 - Kraus, Werner T1 - The Crucial Role of the Diphosphine Heteroatom X in the Stereochemistry and Stabilization of the Substitution-Inert [M(N)(PXP)]2+ Metal Fragments (M = Tc, Re; PXP = Diphosphine Ligand) N2 - The nature of the heteroatom X incorporated in the five-membered PXP-diphosphine bridging chain was found to play a primary unit role both in the overall stability and in the stereochemical arrangement of nitrido-containing [M(N)(PXP)]2+ metal fragments (M = Tc, Re). Thus, by mixing PXP ligands with labile [Re(N)Cl4]- and Tc(N)Cl2(PPh3)2 nitrido precursors in CH2Cl2/MeOH mixtures, a series of neutral M(N)Cl2(PXP) complexes (M = Tc, 1-5; M = Re, 8, 9) was collected. In the resulting distorted octahedrons, PXP adopted facial or meridional coordination, and combination with halide co-ligands produced three different stereochemical arrangements, that is, fac,cis, mer,cis, and mer,trans, depending primarily on the nature of the diphosphine heteroatom X. When X = NH, mer,cis-Tc(N)Cl2(PNP1), 1, was the only isomer formed. Alternatively, when a tertiary amine nitrogen (X = NR; R = CH3, CH2CH2OCH3) was introduced in the bridging chain, fac,cis-M(N)Cl2(PN(R)P) complexes (M = Tc, 2, 3; M = Re, 8f) were obtained. Isomerization into the mer,cis-Re(N)Cl2(PN(R)P), 8m, species was observed only in the case of rhenium when the tertiary amine group carried the less encumbering methyl substituent. fac,cis-Tc(N)Cl2(PSP), 4f, was isolated in the solid state when X = S, but a mixture of fac,cis-Tc(N)Cl2(PSP) and mer,trans-Tc(N)Cl2(PSP), 4m, isomers was found in equilibrium in the solution state. A similar equilibrium between fac,cis-M(N)Cl2(POP) (M = Tc, 5f; M = Re, 9f) and mer,trans-M(N)Cl2(POP) (M = Tc, 5m; M = Re, 9m) species was detected in POP-containing complexes. The molecular structure of all of these complexes was assessed by means of conventional physicochemical techniques including multinuclear NMR spectroscopy and X-ray diffraction analysis of representative mer,cis-Tc(N)Cl2(PN(H)P), 1, fac,cis-Tc(N)Cl2(PSP), 4f, and mer,cis-Re(N)Cl2(PN(Me)P), 8m, compounds. PY - 2004 DO - https://doi.org/10.1021/ic049139r SN - 0020-1669 SN - 1520-510X VL - 43 IS - 26 SP - 8617 EP - 8625 PB - American Chemical Society CY - Washington, DC AN - OPUS4-5546 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kraus, Werner A1 - Walther, M. A1 - Jung, C. M. A1 - Emmerling, Franziska A1 - Pietzsch, H.-J. T1 - Bromotricarbonyl{15-[2-(methylsulfanyl)ethylsulfanyl]pentadecanoic acid-kappa2S,S'}rhenium(I) N2 - The title compound, [ReBr(C18H36O2S2)(CO)3], was synthesized and characterized as a non-radioactive surrogate of a novel Tc-containing fatty acid derivative prepared according to the tricarbonyl/dithioether design with the objective of developing new Tc-based radiopharmaceuticals for the non-invasive diagnosis of myocardial metabolism. The Re chelate contains the metal in the oxidation state +1 and is attached to the terminal position of a fatty acid. The complex formation was accomplished by a ligand exchange reaction using [NBu4]2[Re(CO)3Br3] as starting material. KW - Fatty acid KW - Tc-compound KW - Radio-pharmaceutical PY - 2006 DO - https://doi.org/10.1107/S1600536806024081 SN - 1600-5368 VL - 62 IS - 7 SP - m1660 EP - m1662 PB - Munksgaard CY - Copenhagen AN - OPUS4-12529 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -