TY - CONF A1 - Döring, Joachim A1 - Bovtun, V. A1 - Bartusch, Jürgen A1 - Beck, Uwe A1 - Kreutzbruck, Marc T1 - Cellular polypropylene ferroelectret film: piezoelectric material for non-contact ultrasonic transducers T2 - 17th World Conference on Non-Destructive Testing (Proceedings) T2 - 17th World Conference on Non-Destructive Testing CY - Shanghai, China DA - 2008-10-25 KW - Air-coupled ultrasound KW - Ultrasonic transducers KW - Electromechanical properties KW - Piezoelectric materials KW - Impedance spectroscopy PY - 2008 IS - Paper 123 SP - 1 EP - 6 PB - International Committee for Non-Destructive Testing CY - Shanghai AN - OPUS4-18435 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Döring, Joachim A1 - Bovtun, V. A1 - Gaal, Mate A1 - Bartusch, Jürgen A1 - Erhard, Anton A1 - Kreutzbruck, Marc A1 - Yakymenko, Y. T1 - Piezoelectric and electrostrictive effects in ferroelectret ultrasonic transducers JF - Journal of applied physics N2 - Electromechanical response of polypropylene ferroelectret transducers under application of high-voltage pulses was measured by laser Doppler vibrometry and compared with results of ultrasonic through-air transmission between two ferroelectret transducers. The electromechanical response was completely explained by piezoelectric and electrostrictive effects. The electrostrictive effect dominates at high voltages and provides significant enlargement of the transducer constant, up to factor of 2.5. The induced strain of 1.7% was achieved at – 2000 V. The nonlinear ultrasonic transmission was shown to be well described by the piezoelectric and electrostrictive response of transmitter, except in the range of high negative exciting voltages where some limitation of the transmitted signal was observed. This limitation seems not to be a fundamental one and does not abolish the advantages of high-voltage excitation of polypropylene ferroelectret transducers. KW - Electromechanical effects KW - Ferroelectric devices KW - Piezoelectric transducers KW - Piezoelectricity KW - Ultrasonic transducers KW - Ultrasonic transmission KW - Cellular polypropylene KW - Ferroelectret KW - Electrostriction PY - 2012 DO - https://doi.org/10.1063/1.4759052 SN - 0021-8979 SN - 1089-7550 VL - 112 IS - 8 SP - 084505-1 - 084505-6 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-26806 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gaal, Mate A1 - Caldeira, Rui A1 - Bartusch, Jürgen A1 - Schadow, Florian A1 - Vössing, Konrad A1 - Kupnik, M. T1 - Air-coupled ultrasonic ferroelectret receiver with additional bias voltage JF - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control N2 - High sensitivity is an important requirement for air-coupled ultrasonic sensors applied to materials testing. With a lower acoustic impedance than any piezoelectric material, charged cellular polypropylene (PP) offers better matching to air with a similar piezoelectric coefficient. The piezoelectric properties of charged cellular PP originate from their polarization, creating permanent internal voltage. The sensitivity of the sensor can be increased by applying additional dc bias voltage, as it has been done already for transmitters. This work presents the first ultrasonic sensor based on charged cellular PP including a high-voltage module providing dc bias voltage up to 2 kV. This bias voltage led to an increase in the signal-to-noise ratio of up to 15 ± 1 dB. The measurement of the received signal depending on the applied bias voltage is proposed as a new method of determining the internal voltage of ferroelectrets. The sensor combined with a cellular PP transmitter was applied to nondestructive testing of a rotor blade segment and glued-laminated timber, enabling imaging of the internal structure of these specimens with a thickness around 4 cm. KW - Acoustic sensors KW - Ferroelectret KW - Nondestructive testing KW - Ultrasonic imaging KW - Ultrasonic transducers PY - 2019 DO - https://doi.org/10.1109/TUFFC.2019.2925666 SN - 0885-3010 SN - 1525-8955 VL - 66 IS - 10 SP - 1600 EP - 1605 PB - IEEE AN - OPUS4-49131 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -