TY - JOUR A1 - Gaal, Mate A1 - Caldeira, Rui A1 - Bartusch, Jürgen A1 - Schadow, Florian A1 - Vössing, Konrad A1 - Kupnik, M. T1 - Air-coupled ultrasonic ferroelectret receiver with additional bias voltage N2 - High sensitivity is an important requirement for air-coupled ultrasonic sensors applied to materials testing. With a lower acoustic impedance than any piezoelectric material, charged cellular polypropylene (PP) offers better matching to air with a similar piezoelectric coefficient. The piezoelectric properties of charged cellular PP originate from their polarization, creating permanent internal voltage. The sensitivity of the sensor can be increased by applying additional dc bias voltage, as it has been done already for transmitters. This work presents the first ultrasonic sensor based on charged cellular PP including a high-voltage module providing dc bias voltage up to 2 kV. This bias voltage led to an increase in the signal-to-noise ratio of up to 15 ± 1 dB. The measurement of the received signal depending on the applied bias voltage is proposed as a new method of determining the internal voltage of ferroelectrets. The sensor combined with a cellular PP transmitter was applied to nondestructive testing of a rotor blade segment and glued-laminated timber, enabling imaging of the internal structure of these specimens with a thickness around 4 cm. KW - Acoustic sensors KW - Ferroelectret KW - Nondestructive testing KW - Ultrasonic imaging KW - Ultrasonic transducers PY - 2019 DO - https://doi.org/10.1109/TUFFC.2019.2925666 SN - 0885-3010 SN - 1525-8955 VL - 66 IS - 10 SP - 1600 EP - 1605 PB - IEEE AN - OPUS4-49131 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate A1 - Dohse, Elmar A1 - Bartusch, Jürgen A1 - Kreutzbruck, Marc T1 - Luftultraschallprüfung von CFK mit planaren und fokussierenden Wandlern N2 - Für die Prüfung von Leichtbaustrukturen ist in den letzten Jahren ein vermehrter Einsatz der Luftultraschallprüfung zu verzeichnen. Insbesondere eignet sich Luftultraschall für die Prüfung von Faserkunststoffverbunden und hybrider Werkstoffverbunde, die ihre Anwendung in der Automobilindustrie und Luftfahrt finden. Für den Bau von marktüblichen Luftultraschall-Wandlern werden Piezokomposite mit Anpassschichten versehen. Ihre Herstellung ist allerdings sehr anspruchsvoll und die erreichbaren Signal-Rausch-Abstände sind für viele Prüfprobleme als noch nicht ausreichend einzustufen. Zwecks gesteigerter Effizienz beim Schallübertrag in die Luft wurden Luftultraschall-Sender und -Empfänger aus zellulärem Polypropylen entwickelt. Dieses piezoelektrische Material ist aufgrund seiner geringer Dichte und seiner sehr geringen Schallgeschwindigkeit an die niedrige akustische Impedanz der Luft deutlich besser angepasst, als die üblicherweise verwendeten Anpassschichten. Letztere können bei Polypropylen-Wandlern daher gänzlich vermieden werden. In diesem Beitrag wird Luftultraschall-Prüfung an zwei verschiedenen CFK-Testkörpern vorgestellt: an einer Platte mit T-Stringern aus dem Seitenleitwerk eines Flugzeugs und an einer Platte mit künstlich eingebrachten Fehlern. Es wurde mit unterschiedlichen planaren und fokussierenden Wandlern geprüft. Marktübliche Wandler mit Anpassschichten wurden mit den selbstentwickelten Wandlern aus zellulärem Polypropylen verglichen. Der Signal-Rausch-Abstand und die laterale Auflösung wurden sowohl im Prüfaufbau mit senkrechter Einschallung als auch mit Schrägeinschallung gemessen. Die Ergebnisse zeigen, dass die Schrägeinschallung zwar den Signal-Rauschabstand erhöht, aber die laterale Auflösung verschlechtern kann. T2 - DACH Jahrestagung 2015 CY - Salzburg, Austria DA - 11.05.2015 PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-349751 UR - http://jt2015.dgzfp.de/Portals/jt2015/BB/mi1a3.pdf SP - Mi.1.A.3-1 EP - Mi.1.A.3-9 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-34975 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate A1 - Daschewski, Maxim A1 - Bartusch, Jürgen A1 - Schadow, Florian A1 - Dohse, Elmar A1 - Kreutzbruck, Marc A1 - Weise, Matthias A1 - Beck, Uwe T1 - Novel air-coupled ultrasonic transducer combining the thermoacoustic with the piezoelectric effect N2 - In recent years, there has been an increasing industrial demand for one-sided inspection of various structures by means of air-coupled ultrasonic technique. Lightweight structures based on carbon-fibre-reinforced polymers may have very complex shapes, making air-coupled transmission difficult or even impossible. The inspection of concrete structures is another example where one-sided inspection is required. To address these challenges a new type of transducer for air-coupled pulse-echo inspection was developed, which unites two principles: thermoacoustic emission and piezoelectric reception. The thermoacoustic emitter is a titanium electrode with a thickness of several tens of nanometer. This electrode was deposited onto charged cellular polypropylene, which serves as a piezoelectric receiver. The thermoacoustic transmission is based on a transformation of the thermal energy of an electrically heated electrode into the acoustic energy of an ultrasonic wave. Thermoacoustic emitters provide resonance-free behaviour and thus extremely broadband pulses. Charged cellular polypropylene is piezoelectric due to the polarization of its cells and it is well matched to air, with a Young modulus in the order of magnitude of MPa. In this contribution we present some pulse-echo measurements with the first prototypes of the combined thermoacoustic-piezoelectric transducer. T2 - World Conference of Non-Destructive Testing CY - Munich, Germany DA - 13.6.2016 KW - Thermoacoustic KW - Piezoelectric KW - Ultrasonic transducer KW - Ferroelectret PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-367151 VL - 158 SP - Mo.1.F.4, 1 EP - 6 AN - OPUS4-36715 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schadow, Florian A1 - Gaal, Mate A1 - Bartusch, Jürgen A1 - Dohse, E. A1 - Köppe, Enrico T1 - Focusing air-coupled ultrasonic transducers based on ferroelectrets N2 - Rising importance of composite lightweight structures in aircraft and automobile industries increases the demand on reliable non-destructive testing methods for these structures. Air-coupled ultrasonic testing emerged to suit these requirements as it does not require any liquid coupling medium. In conventional air-coupled ultrasonic transducers, matching layers are used in order to decrease the impedance mismatch between transducer and air. Matching layers can be omitted by using ferroelectrets, which are charged cellular polymers having ferroelectric and piezoelectric properties. Especially a low Young’s modulus, low density and low sound velocity of cellular polypropylene (cPP) are properties being required for well-matched air-coupled ultrasonic transducers. In our contribution we show recent enhancements of cPP transducers resulting in focused sound fields and thus improved lateral sensitivity. The influence of different transmitter apertures was evaluated using measurements of the emitted sound field. Further we show a transmission of a test specimen of carbon-fiber-reinforced plastic (CFRP) containing artificial damages. Results of focused transducers were compared to planar ferroelectret transducers, as well as to conventional air-coupled transducers. T2 - 19th World Conference on Non-Destructive Testing 2016 CY - München, Germany DA - 13.06.2016 KW - Air-coupled ultrasonic testing KW - Ferroelectrets KW - Cellular polypropylene KW - Focused sound fields KW - Focused transducers PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-355116 UR - http://www.ndt.net/search/docs.php3?showForm=off&id=19453 SP - 1 EP - 8 AN - OPUS4-35511 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gaal, Mate A1 - Caldeira, Rui A1 - Bartusch, Jürgen A1 - Kupnik, M. T1 - Air-coupled ultrasonic ferroelectret receiver with additional DC voltage N2 - Highly sensitive air-coupled ultrasonic sensors are essential for various applications such as testing of composite materials. One of the major challenges for the development of air-coupled ultrasonic sensors is the impedance matching to air. With a lower acoustic impedance than the usual piezoelectric materials, charged cellular polypropylene film (cPP) offers better matching to air with a similar piezoelectric coefficient. The piezoelectric behaviour demonstrated by cPP comes from polarized air cells that create a permanent internal voltage. The sensitivity of the sensor varies with the application of an additional DC bias voltage. Thus, this work presents a cPP ultrasonic sensor with an improvement of up to 15 ± 1 dB on the signal-to-noise ratio. T2 - Eurosensors 2017 CY - Paris, France DA - 3.9.2017 KW - Ultrasonic KW - Air-coupled KW - Cellular polypropylene KW - Transducer KW - Ferroelectret PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-419009 DO - https://doi.org/10.3390/proceedings1040362 VL - 1 IS - 4 SP - Article 362, 1 EP - 4 AN - OPUS4-41900 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -