TY - CONF A1 - Retter, Utz A1 - Koch, Matthias A1 - Nehls, Irene T1 - Rückgewinnung von Mineralölen durch Salzbrechung von Öl-Wasser-Emulsionen T2 - Veranstaltung der SEPAWA T2 - Veranstaltung der SEPAWA CY - Berlin, BAM, Deutschland DA - 2000-09-08 PY - 2000 AN - OPUS4-956 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Nehls, Irene T1 - Ringversuche: Präparation mineralölkohlenwasserstoffhaltiger Abwasserproben JF - Vom Wasser KW - Analytik KW - Ringversuch KW - Abwasser KW - Mineralölkohlenwasserstoff KW - Probe KW - Qualitätssicherung KW - Chemical analysis KW - Interlaboratory comparison KW - Wastewater KW - Mineral oil KW - Sample KW - Quality assurance PY - 2008 SN - 0083-6915 VL - 106 IS - 3 SP - 7 EP - 8 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-18289 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dorgerloh, Ute A1 - Erhardt, Ulla A1 - Schmieder, Rosmarie A1 - Walter, W. A1 - Win, Tin A1 - Hilbert, S. A1 - Mechler, M. A1 - Nehls, Irene T1 - Ringversuch zur Bestimmung von leichtflüchtigen halogenierten Kohlenwasserstoffen (LHKW), Vinylchlorid (VC) und Fluorchlorkohlenwasserstoffen (FCKW) in Grundwasser JF - Vom Wasser KW - Analytik KW - Grundwasser KW - Leichtflüchtige halogenierte Kohlenwasserstoffe (LHKW) KW - Vinylchlorid (VC) KW - Fluorchlorkohlenwasserstoffe (FCKW) KW - Ringversuch KW - Analytics KW - Groundwater KW - Highly volatile halogenated hydrocarbons (VHHC) KW - Vinyl chloride (VC) KW - Chlorofluorocarbons (CFC) KW - Interlaboratory comparison PY - 2004 SN - 0083-6915 VL - 102 IS - 2 SP - 12 EP - 16 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-4126 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Krüger, Rita A1 - Koch, Matthias A1 - Nehls, Irene T1 - Ringversuch für Acrylamid, Theobromin und Coffein in Kakao JF - Lebensmittelchemie KW - Ringversuch KW - Acrylamid KW - Theobromin KW - Coffein KW - Kakao PY - 2008 SN - 0937-1478 SN - 1521-3811 VL - 62 IS - 4 SP - 110 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-17848 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nehls, Irene T1 - Ressortforschung und Analytische Chemie - Möglichkeiten und Grenzen T2 - Eingeladener Vortrag im GKSS Institut für Chemie in Teltow-Seehof T2 - Eingeladener Vortrag im GKSS Institut für Chemie in Teltow-Seehof CY - Teltow, Germany DA - 2005-02-18 PY - 2005 AN - OPUS4-7519 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Philipp, B. A1 - Wagenknecht, W. A1 - Nehls, Irene A1 - Klemm, D. A1 - Stein, A. A1 - Heinze, Th. T1 - Regioselective derivatization of cellulose-routes of synthesis, effects on properties and areas of application JF - Polymer news KW - Zellulose KW - Routing KW - Regioselektivität PY - 1996 SN - 0032-3918 SN - 0370-050X VL - 21 SP - 115 EP - 161 PB - Gordon and Breach CY - New York, NY AN - OPUS4-701 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Nehls, Irene A1 - Buge, Hans-Gerhard T1 - Referenzmaterialien für Umweltanalysen JF - GIT : Labor-Fachzeitschrift PY - 2001 SN - 0016-3538 IS - 45 SP - 1089 EP - 1091 PB - GIT-Verlag CY - Darmstadt AN - OPUS4-1186 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Koch, Matthias A1 - Krüger, Rita A1 - Nehls, Irene T1 - Referenzmaterialien für Ochratoxin A in Kaffee und Wein JF - Lebensmittelchemie KW - Ochratoxin A KW - Referenzmaterial KW - ERM KW - Kaffee KW - Wein PY - 2007 SN - 0937-1478 SN - 1521-3811 VL - 61 IS - 4 SP - 102 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-15723 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nehls, Irene T1 - Referenzmaterialien - Instrumente der Qualitätssicherung T2 - Kolloquiumsvortrag auf Einladung der Abt. F+E-Analytic der SKW Stickstoffwerke Piesteritz T2 - Kolloquiumsvortrag auf Einladung der Abt. F+E-Analytic der SKW Stickstoffwerke Piesteritz CY - Lutherstadt Wittenberg, Germany DA - 2002-09-26 PY - 2002 AN - OPUS4-5838 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nehls, Irene T1 - Referenzmaterialien - Instrumente der Qualitätssicherung JF - Nachrichten aus der Chemie PY - 2005 DO - https://doi.org/10.1002/nadc.20050530924 SN - 1439-9598 SN - 1521-3854 VL - 53 SP - 925 EP - 927 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-10844 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nehls, Irene T1 - Referenzmaterialien - Instrumente der Qualitätssicherung T2 - Kolloquium im Fachbereich Chemie der Humboldt-Universität Berlin T2 - Kolloquium im Fachbereich Chemie der Humboldt-Universität Berlin CY - Berlin, Germany DA - 2005-02-24 PY - 2005 AN - OPUS4-11738 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nehls, Irene A1 - Becker, Roland A1 - Win, Tin A1 - Buge, Hans-Gerhard A1 - Koch, Matthias T1 - Referenzmaterialien - Instrimente der Qualitätssicherung T2 - Kolloquium im Fachbereich Chemie der Humboldt-Universität Berlin auf Einladung von Herrn Prof. Linscheid T2 - Kolloquium im Fachbereich Chemie der Humboldt-Universität Berlin auf Einladung von Herrn Prof. Linscheid CY - Berlin, Germany DA - 2004-02-24 PY - 2004 AN - OPUS4-5471 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nehls, Irene T1 - Referenzmaterialien - Basis der internen und externen Qualitätssicherung T2 - Seminar: Referenzmaterialien, Regelkarten, Ringversuche; Klinker & Partner GmbH T2 - Seminar: Referenzmaterialien, Regelkarten, Ringversuche; Klinker & Partner GmbH CY - Saarbrücken, Germany DA - 1999-12-01 PY - 1999 AN - OPUS4-5717 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nehls, Irene T1 - Referenzmaterialien T2 - 4. EUROLAB/D-Kolloquium Bundesanstalt für Materialforschung und /-Prüfung T2 - 4. EUROLAB/D-Kolloquium Bundesanstalt für Materialforschung und /-Prüfung CY - Berlin, Germany DA - 1998-03-27 PY - 1998 AN - OPUS4-5696 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Nehls, Irene A1 - Win, Tin ED - Zschunke, Adolf T1 - Reference Materials in Environmental Studies T2 - Reference materials in analytical chemistry KW - Reference Materials KW - Analytical Chemistry KW - Calibration KW - Method Validation KW - Traceability PY - 2000 SN - 3-540-66776-8 SN - 0933-033X N1 - Serientitel: Springer Series in materials science – Series title: Springer Series in materials science IS - 40 SP - 143 EP - 165 PB - Springer CY - Berlin AN - OPUS4-1013 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nehls, Irene T1 - Reference materials for organic environmental analysis T2 - BERM-7 T2 - BERM-7 CY - Antwerp, Belgium DA - 1997-04-21 PY - 1997 AN - OPUS4-5671 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Köppen, Robert A1 - Koch, Matthias A1 - Emmerling, Franziska A1 - Nehls, Irene T1 - rac-(1R,2R,4S)-1,2-Dibromo-4-[(1R)-1,2-dibromoethyl]cyclohexane JF - Acta crystallographica E N2 - In the title compound, C8H12Br4, the cyclohexane ring exhibits a chair conformation. The C-Br distances range from 1.964 (6) to 1.985 (5) Å and the C-C distances range from 1.496 (6) to 1.543 (7) Å. Short intermolecular BrBr contacts [3.467 (4) Å] occur in the crystal. PY - 2010 DO - https://doi.org/10.1107/S160053681004763X SN - 1600-5368 VL - 66 IS - 12 SP - o3318,sup-1 - o3318,sup-7 PB - Munksgaard CY - Copenhagen AN - OPUS4-22616 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Siegel, David A1 - Merkel, Stefan A1 - Koch, Matthias A1 - Nehls, Irene T1 - Quantification of the Alternaria mycotoxin tenuazonic acid in beer JF - Food chemistry N2 - Tenuazonic acid (TA) is a major water soluble Alternaria mycotoxin. In the present work, a method for the quantification of TA in beer by liquid chromatography-ion-trap multistage mass spectrometry after derivatization with 2,4-dinitrophenylhydrazine is described. The method is based on a rapid workup procedure and features a LOD of 2 µg/kg without preconcentration using 400 mg of sample. Validation was performed for a working range of 8-500 µg/kg. A total of 43 beers of different brewing styles (pilsener, wheat beer, bock beer, dark beer and alcohol free beer) was analysed. TA was detected in 37 samples, 16 samples were above the LOQ. An average content of 11 µg/kg was found, the highest incidence being 175 ± 13 µg/kg. To our knowledge, this is the first report on the occurrence of TA in beer and beverages in general. KW - Tenuazonic acid KW - Mycotoxin KW - Beer KW - 2,4-Dinitrophenylhydrazine KW - Derivatization KW - Liquid chromatography/electrospray ionisation ion-trap multistage mass Spectrome PY - 2010 DO - https://doi.org/10.1016/j.foodchem.2009.10.070 SN - 0308-8146 VL - 120 IS - 3 SP - 902 EP - 906 PB - Elsevier CY - Amsterdam [u.a.] ; Jena AN - OPUS4-21372 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Koch, Matthias A1 - Lehnik-Habrink, Petra A1 - Nehls, Irene T1 - Quantification of polychlorinated biphenyls in plastic granulates from the recycling of cables - Reference materials and interlaboratory comparison JF - Chemosphere N2 - A procedure for the quantification of the PCB marker congeners 28, 52, 101, 138, 153, 180 in plastic waste form the recycling of cables in the range of content between 0.1 mg kg-1 and 20 mg kg-1 was validated. Representative reference materials for laboratory analyses were produced using granulates from different recycling processes. The method development included aspects of grinding, sieving, homogenising as well as the comparison of extraction methods and chromatographic conditions. The validated procedure foresees grinding of the technical sample to an upper particle size limit of 0.50 mm followed by extraction with an unpolar solvent such as n-hexane and gas chromatographic determination. LOD and LOQ for individual congeners ranged between 0.01 mg kg-1 and 0.08 mg kg-1. Electron capture detection (ECD) and mass selective detection (MS) were equivalent if chromatographic conditions were appropriately selected. The application of MS was advantageous in presence of significant amounts of interfering components which have been found in some cables. Three reference materials containing the marker congeners in the range of 0.1 mg kg-1–5 mg kg-1 were submitted to a final validation intercomparison with 23 selected field laboratories using the developed method. Relative reproducibility standard deviations varied between 15% and 33%. KW - PCB KW - Waste KW - Analysis KW - Method validation KW - Standardisation PY - 2006 DO - https://doi.org/10.1016/j.chemosphere.2006.02.035 SN - 0045-6535 SN - 0366-7111 VL - 65 IS - 9 SP - 1652 EP - 1659 PB - Elsevier Science CY - Kidlington, Oxford AN - OPUS4-14050 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mönch, Bettina A1 - Becker, Roland A1 - Nehls, Irene T1 - Quantification of ethyl glucuronide in hair: effect of milling on extraction efficiency JF - Alcohol and alcoholism N2 - Aim: The objective of the study was to provide conclusive evidence for the effect of particle size reduction as by milling on the extractable content of ethyl glucuronide (EtG) of hair samples. Methods: A number of real case hair samples and two pooled hair materials with EtG contents in the range of 10–30 pg/mg were systematically compared with regard to the extraction yield of EtG after cutting to 2–3 mm length and pulverization with a ball mill. After the respective treatment the samples were submitted to aqueous extraction followed by quantification of EtG using HPLC-MS/MS. Results: It was unequivocally demonstrated that milling of hair samples prior to aqueous extraction significantly increases the extractable EtG content compared with cut hair. The effect ranged between 137 and 230% and was seen to occur regardless of the extent of pulverization. Cooling of samples was not necessary to prevent partial degradation of EtG during the grinding procedure. Conclusion: The options currently employed at choice in analytical practice (cutting or milling) were seen to significantly affect the extractable amount of EtG in hair. This is suspected to influence the degree of equivalence of quantification results obtained in different laboratories as well as their respective classification of a test subject's drinking behaviour on the basis of currently recommended cut-off values. PY - 2013 DO - https://doi.org/10.1093/alcalc/agt059 SN - 0735-0414 SN - 0309-1635 SN - 1464-3502 VL - 48 IS - 5 SP - 558 EP - 563 PB - Univ. Press CY - Oxford AN - OPUS4-28843 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -