TY - JOUR A1 - Dorgerloh, Ute A1 - Becker, Roland A1 - Theißen, H. A1 - Nehls, Irene T1 - The quantification of hydrogen and methane in contaminated groundwater: validation of robust procedures for sampling and quantification N2 - A number of currently recommended sampling techniques for the determination of hydrogen in contaminated groundwater were compared regarding the practical proficiency in field campaigns. Key characteristics of appropriate sampling procedures are reproducibility of results, robustness against varying field conditions such as hydrostatic pressure, aquifer flow, and biological activity. Laboratory set-ups were used to investigate the most promising techniques. Bubble stripping with gas sampling bulbs yielded reproducible recovery of hydrogen and methane which could be verified for groundwater sampled in two field campaigns. The methane content of the groundwater was confirmed by analysis of directly pumped samples thus supporting the trueness of the stripping results. Laboratory set-ups and field campaigns revealed that bubble stripping of hydrogen may be restricted to the type of used pump. Concentrations of dissolved hydrogen after bubble stripping with an electrically driven submersible pump were about one order of magnitude higher than those obtained from diffusion sampling. The gas chromatographic determination for hydrogen and methane requires manual injection of gas samples and detection by a pulsed discharge detector (PDD) and allows limits of quantification of 3 nM dissolved hydrogen and 1 µg L-1 dissolved methane in groundwater. The combined standard uncertainty of the bubble stripping and GC/PDD quantification of hydrogen in field samples was 7% at 7.8 nM and 18% for 78 nM. PY - 2010 DO - https://doi.org/10.1039/c0em00091d SN - 1464-0325 SN - 1464-0333 VL - 12 IS - 10 SP - 1876 EP - 1884 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-22176 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Buge, Hans-Gerhard A1 - Becker, Roland A1 - Nehls, Irene T1 - The preparation and characterization of solid matrix reference materials for the trace analysis of organic environmental pollutants - relevant aspects of quality management N2 - Feste Referenzmaterialien für die Spurenanalytik umweltrelevanter organischer Schadstoffe erfordern aufgrund der geringen thermischen Belastbarkeit der Analyten besondere Aufarbeitungsstrategien für die Herstellung repräsentativer Teilproben. Das in der Fachgruppe I.2 seit 1994 für diesen Zweck systematisch aufgebaute technologische Instrumentarium wird vorgestellt, und das im Laufe der Jahre angesammelte Know How wird anhand von Beispielen vermittelt. Das im Laboratorium I.21 entwickelte Qualitätssystem für eine optimale Logistik der Arbeitsabläufe der Probenherstellung und -verwaltung sowie für eine bedarfsgerechte Charakterisierung der Materialien wird ausführlich erläutert. Bezüglich der Verwendung der Referenzmaterialien wird herausgestellt, daß es zwei gleichberechtigte Anwendungsrichtungen gibt: die interne Qualitätskontrolle mit zertifizierten Referenzmaterialien (ZRM, z.B. für die Methodenvalidierung) und die externe Qualitätskontrolle (Proficiency Testing = Kompetenzbewertung von Prüflaboratorien). Referenzmaterialien für das Proficiency Testing, die im Umweltbereich in viel größeren Stückzahlen umgesetzt werden können als ZRM, weisen bezüglich Homogenität und Charakterisierung die gleichen Qualitätskriterien wie ZRM auf. Diese Materialien haben - auch im internationalen Maßstab - stark an Bedeutung gewonnen. Ein englisches Abstract gibt es nicht, aber eine Grobgliederung zur Vortragsankündigung: This lecture includes: · the technological and logistical aspects of reference material preparation and sub-sampling and subsequent sample management, · appropriate measurement strategies for homogeneity and stability studies, · the use of relevant statistical tests to evaluate those measurement data, · the organisation of interlaboratory studies based on traceable measurements T2 - CENAM CY - Querétaro, Mexico DA - 2002-03-01 PY - 2002 AN - OPUS4-1612 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mönch, Bettina A1 - Becker, Roland A1 - Jung, Christian A1 - Nehls, Irene T1 - The homogeneity testing of EtG in hair reference materials: A high-throughput procedure using GC-NCI-MS N2 - The validation of a robust quantification procedure for EtG in hair using GC–NCI–MS is presented. Aqueous extraction is followed by complete lyophylization of the extract and derivatization with pentafluoropropionic anhydride (PFPA) under controlled temperature and duration. Clean-up of extracts was dispensable and standard single quadrupole MS displayed sufficient selectivity and sensitivity. The method displayed a wide linearity range and enabled LOD of 0.68 pg/mg, LOQ of 2.4 pg/mg, and precision below 8.12%. Since EtG was seen to display prolonged stability in the aqueous extracts and after derivatization with PFPA this straightforward procedure allows a routine throughput of large quantities of samples with little proneness to procedural scatter of results. The method was applied to demonstrate the homogeneity of two hair reference materials with mean EtG contents of 8.48 pg/mg and 22.0 pg/mg. Aside from the application in homogeneity studies of hair reference materials predominantly in the concentration range of 10–50 pg/mg the method was also designed for daily routine quantification of real-world sample with regard to drinking behavior assessment. KW - Extraction KW - Derivatization KW - High-throughput analysis KW - Reference materials KW - Homogeneity KW - Measurement uncertainty PY - 2013 DO - https://doi.org/10.1016/j.forsciint.2013.01.018 SN - 0379-0738 SN - 1872-6283 VL - 226 IS - 1-3 SP - 202 EP - 207 PB - Elsevier Ltd. CY - Amsterdam [u.a.] AN - OPUS4-27998 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Buge, Hans-Gerhard A1 - Nehls, Irene T1 - The determination of adsorbable organically bound halogens (AOX) in soil: interlaboratory comparisons and reference materials N2 - The interlaboratory variability in the quantification of adsorbable organically bound halogens (AOX) in industrially contaminated soil is presented. Three consecutive rounds of a proficiency testing scheme, in which between 88 and 119 routine laboratories participated, yielded relative reproducibility standard deviations between 7 and 20% at AOX contents between 10.9 and 268 mg kg-1. Nineteen laboratories with established proficiency were invited to participate in the certification of the AOX content in three soil reference materials meant for the internal quality control in analytical laboratories. The certified values are (1349 ± 59) mg kg-1, (80 ± 7) mg kg-1 and (102 ± 8) mg kg-1, respectively. KW - Certified reference materials KW - European Reference Material KW - Proficiency testing KW - Organohalogen compounds KW - Summation parameter PY - 2007 DO - https://doi.org/10.1007/s00769-007-0308-z SN - 0949-1775 SN - 1432-0517 VL - 12 IS - 12 SP - 647 EP - 651 PB - Springer CY - Berlin AN - OPUS4-16670 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Esslinger, Susanne A1 - Becker, Roland A1 - Jung, Christian A1 - Schröter-Kermani, C. A1 - Bremser, Wolfram A1 - Nehls, Irene T1 - Temporal trend (1988-2008) of hexabromocyclododecane enantiomers in herring gull eggs from the german coastal region N2 - Levels of α-, β-, and γ-hexabromocyclododecane (HBCD) were determined in pooled eggs from herring gulls (Larus argentatus) sampled on three bird sanctuaries near the German North Sea coast between 1988 and 2008 (Mellum and Trischen) and the German Baltic Sea coast between 1998 and 2008 (Heuwiese) and archived by the German Environmental Specimen Bank. Pressurized fluid extraction, gel permeation chromatography, and LC–MS/MS using 13C12-labelled isotope standards and a chiral column were applied. α-HBCD was the dominating diastereomer and ranged between 3.7 and 107 ng g-1 lw while β- and γ-HBCD were throughout close to LOQ. The highest α-HBCD concentration was found in eggs from Mellum sampled in the year 2000. Interestingly, HBCD in eggs from the three islands displayed similar time courses with levels increasing to a peak contamination around 2000 and decreasing levels ever since. Chiral signatures of α-HBCD in eggs differed among the islands but indicated a preferential enrichment of the first eluting enantiomer (-)-α-HBCD. KW - Brominated flame retardant KW - Chiral separation KW - HPLC-ESI-MS/MS KW - Enantiomer-specific bioaccumulation PY - 2011 DO - https://doi.org/10.1016/j.chemosphere.2010.12.047 SN - 0045-6535 SN - 0366-7111 VL - 83 IS - 2 SP - 161 EP - 167 PB - Elsevier Science CY - Kidlington, Oxford AN - OPUS4-23351 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lischka, Susanne A1 - Körte, F. A1 - Faust, R. A1 - Nehls, Irene A1 - Piechotta, Christian T1 - Synthesis, characterization and application of a two-fold 13C-labeled calibration standard for the analysis of arsenobetaine using HPLC-ESI-MS/MS without high resolution mass spectrometry N2 - A procedure has been developed for the determination of arsenobetaine in fish matrix by HPLC–ESI-MS/MS. Hereby (trimethylarsonium)-1,2-13C-acetate (arsenobetaine) is used as internal calibration standard. Arsenobetaine was determined in a fish material (Sea Bass) with an expanded uncertainty of 3.8%. KW - Arsenobetaine KW - ESI-MS/MS KW - Isotopic labeled KW - 13C PY - 2011 DO - https://doi.org/10.1016/j.talanta.2011.07.047 SN - 0039-9140 VL - 85 IS - 4 SP - 1996 EP - 1999 PB - Elsevier CY - Amsterdam AN - OPUS4-25163 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nehls, Irene T1 - Standard-Referenzmaterialien als Instrumente der Qualitätssicherung T2 - Kolloquium im Institut für Spektrochemie und Angewandte Spektroskopie (ISAS) in Dortmund auf Einladung von Herrn Dr. Korte CY - Dortmund, Germany DA - 2004-03-09 PY - 2004 AN - OPUS4-5472 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nehls, Irene A1 - Becker, Roland A1 - Win, Tin A1 - Bremser, Wolfram T1 - Stabilitätsuntersuchungen an einem neuen Referenzmaterial: Nitroaromaten in Boden T2 - Analytica Conference 2002 CY - Munich, Germany DA - 2002-04-23 PY - 2002 AN - OPUS4-5846 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ammann, Dominic A1 - Becker, Roland A1 - Nehls, Irene T1 - Stability of ethyl glucuronide in hair reference materials after accelerated aging N2 - Two different hair reference materials, one produced from authentic hair displaying an ethyl glucuronide (EtG) content of about 25 pg/mg and one obtained by fortification of blank hair to an EtG level of 85 pg/mg were submitted to accelerated aging between 4 degrees C and 60 degrees C for periods between one and 24 months. Subsequently, the EtG content was determined in the aged samples and untreated reference samples stored at -22 degrees C under repeatability conditions following the so-called isochronous approach. The EtG content remained stable even at 40 degrees C for 24 months and at 60 degrees C over six months. This is in contrast to many organic analytes contained in trace concentrations in diverse matrices. A slight but significant increase of the recovered EtG in case of authentic hair samples having been exposed for 24 months between 4 degrees C and 60 degrees C may be due to a temperature-driven process that allows increased recoveries of the physiologically embedded EtG. KW - Alcohol marker KW - Micropulverization KW - HPLC-MS/MS KW - Fortification KW - Long term stability PY - 2015 DO - https://doi.org/10.1016/j.forsciint.2015.09.015 SN - 0379-0738 SN - 1872-6283 VL - 257 SP - 337 EP - 340 PB - Elsevier Ireland Ldt. CY - Amsterdam [u.a.] AN - OPUS4-34940 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Becker, Roland A1 - Dorgerloh, Ute A1 - Theißen, H. A1 - Nehls, Irene T1 - Stabilisation of groundwater samples for the quantification of organic trace pollutants N2 - The concentration of contaminants in groundwater samples can be decreased by degradation in the time course between field sampling and quantification in the laboratory, especially in samples from sites where degradation activity is enhanced by remediation measures. The sampling sites covered a variety of priority organic pollutants such as volatile aromatic and chlorinated compounds, phenols and petroleum hydrocarbons and different remediation strategies such as anaerobic and aerobic microbial in situ degradation, in situ chemical oxidation, and on-site purification with biological treatment. The stability of the contaminants' concentration was investigated over a time range of several hours without cooling in the autosampler of the analytical equipment (short term) and over several days of storage until analysis (long term). A number of stabilisation techniques suggested in international standards ISO 5667-3:2013 and ASTM D6517:2000 were compared both with regard to short term and long term stabilisation of the contaminants and their practicability for field sampling campaigns. Long term storage turned out to be problematic for most compound groups even under cooling. Short term stability was problematic also for volatiles such as benzenic aromates, naphthalene and volatile organic halogenated compounds to be analysed by headspace gas chromatography. Acidification (pH <2) was sufficient to prevent degradation of benzenic aromates, naphthalene, phenols and petrol hydrocarbons for up to seven days. The use of acids was not applicable to stabilise volatiles in waters rich in carbonates and sulphides due to stripping of the volatiles with the liberated gases. The addition of sodium azide was successfully used for stabilisation of volatile organic halogenated compounds. KW - Groundwater KW - Sampling KW - Organic pollutants KW - Stabilisation KW - Analysis PY - 2013 DO - https://doi.org/10.1039/c3em00332a SN - 2050-7887 SN - 2050-7895 VL - 15 IS - 12 SP - 2329 EP - 2337 PB - RSC Publ. CY - CambridgeRSC Publ. AN - OPUS4-29689 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -