TY - JOUR A1 - Hüsken, Götz A1 - Pirskawetz, Stephan A1 - Hofmann, Detlef A1 - Basedau, Frank A1 - Gründer, Klaus-Peter A1 - Kadoke, Daniel T1 - The load-bearing behaviour of a reinforced concrete beam investigated by optical measuring techniques N2 - Bending beams and slabs are typical examples for structural elements used for reinforced concrete structures such as bridge girders, T-beams and bridge decks. Their strength related failure modes at maximum loading can be divided into bending and shear failure. The failure of beams loaded in bending can occur with or without indication. Therefore, conventional design concepts aim on failure modes with sufficient indication (e.g. large deflections or cracks), as it occurs in the case of secondary flexural compression failure. These indicating factors can also be used for Structural Health Monitoring (SHM) of civil infrastructure systems (e.g. bridges) to identify structural changes. In this context, non-destructive testing (NDT) methods offer different techniques for measuring deflections or crack formation and opening. However, profound knowledge on the determining failure modes of bending beams and their detection by NDT methods is required for the reliable application of SHM. Different NDT methods have been used in this study for analysing the load-bearing behaviour of a reinforced concrete beam in bending. The different measuring techniques are briefly described and their applicability is discussed by means of experimental results. For this purpose, the load-bearing behaviour of a reinforced concrete beam having a span of 2.75 m was investigated in a four-point bending flexural test at laboratory scale. The focus is on the characterization of determining failure modes by optical NDT and the comparison with classical measuring techniques (e.g. deformation measurements by displacement transducers). The bending beam was equipped with two single-mode (SM) sensor fibres. One fibre served as Distributed Optical Fibre Sensor (DOFS), whereas the other fibre contained Fibre Bragg Grating (FBG) sensors. In addition, optical deformation measurements using Digital Image Correlation (DIC) and Stereophotogrammetry (SP) were conducted. KW - Concrete beam KW - Bending KW - Digital image correlation KW - Stereophotogrammetry KW - Distributed fibre optic sensor KW - Fibre bragg grating PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-524762 DO - https://doi.org/10.1617/s11527-021-01699-6 VL - 54 IS - 3 SP - Article 102 PB - Springer AN - OPUS4-52476 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pirskawetz, Stephan A1 - Steinbock, O. A1 - Hille, Falk A1 - Schmidt, S. A1 - Hofmann, Detlef T1 - Erfahrungen aus dem Rückbau der Brücke am Altstädter Bahnhof in der Stadt Brandenburg - Teil 2: Schadensmonitoring bei zerstörenden Versuchen N2 - Im Dezember 2019 wurden bei einer turnusmäßigen Inspektion der B 1-Brücke am Altstädter Bahnhof in Brandenburg an der Havel massive und schnell voranschreitende Schäden festgestellt. Als Ursache für die Risse entlang der Längsträger wurde das Versagen eines signifikanten Anteils der Spanndrähte der konzentrierten Spannglieder vermutet. Die Brücke wurde umgehend für den Verkehr gesperrt und im Mai 2021 gesprengt. Im Vorfeld der Sprengung wurden durch das Bundesministerium für Digitales und Verkehr (BMDV) weiterführende Untersuchungen zum Schadensbild veranlasst, welche vom Landesbetrieb Straßenwesen Brandenburg koordiniert und in den Bauablauf integriert wurden. Das von der Hochschule für Technik und Wirtschaft (HTW) Dresden erstellte Versuchskonzept ist Bestandteil des vorangestellten ersten Teils des Beitrags [1]. Hier im zweiten Teil werden ausgewählte Ergebnisse der umfangreichen versuchsbegleitenden Mess- und Monitoringmaßnahmen beschrieben, welche in Kooperation der HTW Dresden, der Bilfinger Noell GmbH sowie der Bundesanstalt für Materialforschung und -prüfung (BAM) durchgeführt wurden. N2 - A routine inspection of the B1 bridge at the Altstädter Bahnhof in Brandenburg an der Havel in December 2019 revealed massive and rapidly progressing damage. The cause of the cracks along the longitudinal girders was suspected to be the failure of a significant portion of the prestressing wires of the concentrated tendons. The bridge was immediately closed to traffic and demolished in May 2021. Prior to the demolition, the Federal Ministry for Digital and Transport (BMDV) initiated further investigations into the damage pattern, which were coordinated and integrated into the deconstruction process by the Landesbetrieb Straßenwesen Brandenburg. The test concept was developed by the Hochschule für Technik und Wirtschaft Dresden (HTW) and is described in the previous article (Part 1). The article at present (Part 2) describes selected results of the extensive measurement and monitoring measures accompanying the tests. The Tests were carried out in cooperation with the HTW Dresden, Bilfinger Noell GmbH and the Bundesanstalt für Materialforschung und -prüfung (BAM). KW - Spannbetonbrücke KW - Spannstahlbruch KW - Schallemission KW - Fotogrammetrie KW - Faseroptik KW - Stochastische Subspacebasierte Schadensdetektion PY - 2022 DO - https://doi.org/10.1002/best.202200052 SN - 1437-1006 VL - 117 IS - 8 SP - 581 EP - 589 PB - Ernst & Sohn CY - Berlin AN - OPUS4-55513 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hüsken, Götz A1 - Shamsuddoha, Md A1 - Pirskawetz, Stephan A1 - Hofmann, Detlef A1 - Baeßler, Matthias A1 - Kühne, Hans-Carsten T1 - Potential of a Repair System for Grouted Connections in Offshore Structures: Development and Experimental Verification N2 - Grouted connections are intensively used in offshore rigs, platforms as well as jacket and monopile offshore wind turbine structures. Being located in remote offshore conditions, these connections can experience considerable adverse loading during their lifetimes. Degradation was reported inside similar connections, which were installed in the last three decades. Grouting in the offshore sites may often be proven difficult, which eventually leads to reduced load-bearing capacity of connections in the long run. Thus, repair and rehabilitation of such connections should be planned ahead to minimize operational delays and costs. In this study, scaled grouted connections were manufactured using a novel mould, whose integrity were monitored using digital image correlation (DIC). The connections were loaded under static load to visualize the main failure pattern using distributed fibre optic sensors and acoustic emission (AE) analysis. Grouted connections were then repaired using a cementitious injectable grout. The effectiveness of the grout injection was monitored using dye penetration technique. Finally, specimens are reloaded to identify the potential of such repair for grouted connections. KW - Offshore KW - Grouted connection KW - Fibre optic sensors KW - Acoustic emission analysis KW - Cracks KW - Repair KW - Rehabilitation KW - Static loading PY - 2021 DO - https://doi.org/10.1016/j.marstruc.2021.102934 VL - 77 SP - 102934 PB - Elsevier Ltd. AN - OPUS4-52059 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lay, Vera A1 - Mielentz, Frank A1 - Prabhakara, Prathik A1 - Baensch, Franziska A1 - Johann, Sergej A1 - Hofmann, Detlef A1 - Sturm, Patrick A1 - Stamm, Michael A1 - Niederleithinger, Ernst T1 - Multi-sensory monitoring and ultrasound for quality assurance at underground sealing structures N2 - Within the safety concepts of underground disposal sites of nuclear waste, engineered barriers play an important role. As these sealing structures have high demands concerning integrity, we aim at advancing the available construction materials, monitoring, and inspection techniques within the project SealWasteSafe. A specifically developed alkali-activated material is compared to classical salt concrete. A comprehensive multi-sensory monitoring scheme is used at 150-340 l specimens to monitor setting and hardening of both materials. All sensors are demonstrated to resist the highly alkaline environments. Besides cabled and wireless temperature and humidity of the materials, strain variations using fibre optic sensors and acoustic emissions are recorded over periods of at least 28 days, partly for more than eight months. After hardening of the specimens, further nondestructive evaluations using ultrasonic echo and thermographic measurements are conducted. Preliminary results proof the suitability of the tested sensors and clearly highlight differences between the tested materials. Particularly, the newly developed alkali-activated material shows lower acoustic emission activity indicating less cracking activity. Additionally, unique ultrasonic methods will enable better images of potential internal objects and cracks at in-situ sealing structures. A largescale ultrasonic system is optimised to reliably detect objects at a depth exceeding 9 m while still obtaining a good resolution. Modelling studies show the potential of further increasing the distance between individual transducer arrays. Additionally, a new ultrasonic borehole probe using phased arrays allowing for beam focussing is constructed and tested. Laboratory measurements at a halfcylindrical concrete specimen coincide well with the previous modelling. In total, the presented safe materials, detailed monitoring approaches and ultrasonic quality assurance methods will help to obtain safe sealing structures within salt as a host rock. The concepts can partly be transferred to sealing structures in alternative host rocks and will also be valuable for non-nuclear waste repositories. T2 - NDE NucCon CY - Espoo, Finland DA - 25.01.2023 KW - SealWasteSafe KW - Engineered barriers KW - Monitoring KW - Embedded sensors KW - Ultrasonic imaging PY - 2023 SP - 2 EP - 10 AN - OPUS4-56928 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -