TY - JOUR A1 - Wirth, Thomas A1 - Beck, Uwe A1 - Hoffmann, V. A1 - Kurt, R. A1 - Kämmer, K. A1 - Thielsch, R. T1 - Interference Phenomena at Transparent Layers in Glow Discharge Optical Emission Spectrometry KW - Glow discharge optical emission spectroscopy KW - Depth profile KW - Interference KW - Transparent layers KW - Layer thickness KW - Refractive index KW - GD-OES PY - 1999 SN - 0003-7028 SN - 1943-3530 VL - 53 IS - 8 SP - 987 EP - 990 PB - Society for Applied Spectroscopy CY - Frederick, Md. AN - OPUS4-777 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beck, Uwe A1 - Wirth, Thomas A1 - Sahre, Mario A1 - Männ, Marion A1 - Gamer, Nadja A1 - Hoffmann, V. A1 - Hentschel, R. A1 - Brauneck, U. A1 - Mollenhauer, R. ED - Berg, S. T1 - Reference coatings for gdoes depth profiling - Preliminary results of a VAMAS project T2 - 7th International Conference on Plasma Surface Engineering (PSE 2000) CY - Garmisch-Partenkirchen, Germany DA - 2000-09-17 PY - 2000 SN - 0257-8972 IS - 142-144 PB - Elsevier CY - Amsterdam AN - OPUS4-970 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Plotnikov, Alexei A1 - Pfeifer, Jens A1 - Richter, Silke A1 - Kipphardt, Heinrich A1 - Hoffmann, V. T1 - Determination of major nonmetallic impurities in magnesium by glow discharge mass spectrometry with a fast flow source using sintered and pressed powder samples N2 - Fast flow glow discharge mass spectrometry with a Grimm-type ion source providing a high sputter rate was used for the determination of major nonmetallic impurities in magnesium. The analytical signal was found to be strongly influenced by the electrical discharge parameters. For calibration by standard addition, synthetic standard samples were produced in two different ways—namely, by pressing and by sintering doped metal powders. The observed sensitivity of the calibration curves was shown to depend on the particle size of the powder. For the magnesium powders, the mass fractions of oxygen, nitrogen, boron, and silicon were determined to be about 0.01 kg·kg-1 (relative standard deviation approximately 10–20 %), 2,700 mg·kg-1, 150 mg·kg-1, and 300 mg·kg-1, respectively. KW - Glow discharge mass spectrometry KW - Magnesium matrix KW - Nonmetallic impurities KW - Fast flow source KW - Electrical parameters KW - Calibration samples KW - Non-metals KW - Standard samples KW - Powders PY - 2014 DO - https://doi.org/10.1007/s00216-014-8185-x SN - 1618-2642 SN - 1618-2650 VL - 406 IS - 29 SP - 7463 EP - 7471 PB - Springer CY - Berlin AN - OPUS4-31975 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hoffmann, V. A1 - Uhlemann, M. A1 - Richter, Silke A1 - Pfeifer, jens T1 - Calibration capacity of hot-pressed hydrogen standards for glow discharge optical emission and mass spectrometry N2 - Mixed copper and titanium hydride powder was hot-pressed and characterized by Carrier Gas Hot Extraction, XRay Diffraction, Thermal Gravimetric Analysis coupled with Mass Spectrometry, and Scanning Electron Microscopy. The hot-pressed and five conventional samples were applied for calibration of hydrogen in Glow Discharge Optical Emission and Mass Spectrometry. Up to the introduction of 15 ng/s hydrogen the Emission yield model is useful in Glow Discharge Optical Emission Spectrometry. A correlation between saturation and even reversal of the emission yield of the spectral lines H121, H486 and H656 and low sputtering rates was found. Hydrogen effects exist for the spectral lines of Cu(II) 219 and Ti(I) 399. In Glow Discharge Mass Spectrometry, a linear dependency of the 1H ion current on the sputtered mass per time exists over the total range of hydrogen content investigated. Hydrogen effects also exist for the sensitivity of 48Ti and 63Cu. The sputtering rate of two-phase materials depends linearly on the sputtered mass per time of one phase, which allows the sputtering rate of two-phase materials with known composition to be predicted. KW - Hot-pressing KW - GD-OES KW - GD-MS KW - Calibration KW - Hydrogen KW - Titanium hydride KW - Sputtering KW - Two-phase system PY - 2021 DO - https://doi.org/10.1016/j.sab.2020.106039 VL - 176 SP - 106039 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-52074 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Engel, A. A1 - Ottermann, C. A1 - Resch-Genger, Ute A1 - Hoffmann, Katrin A1 - Schweizer, S. A1 - Selling, J. A1 - Spaeth, J.-M. A1 - Rupertus, V. ED - Grzymala, R. ED - Haeberlé, O. T1 - Glass based fluorescence reference materials used for optical and biophotonic applications N2 - Fluorescence techniques are known for their high sensitivity and are widely used as analytical tools and detection methods for product and process control, material sciences, environmental and biotechnical analysis, molecular genetics, cell biology, medical diagnostics, and drug screening. For routine measurements by fluorescence techniques the existence of an improved quality assurance is one of the basic needs. According to DIN/ISO 17025 certified standards are used for fluorescence diagnostics having the drawback of giving relative values only. Typical requirements onto fluorescence reference materials or standards deal with the verification of the instrument performance as well as the improvement of the data comparability. Especially for biomedical applications fluorescence labels are used for the detection of proteins. In particular these labels consist of nano crystalline materials like CdS and CdSe. The field of Non-Cadmium containing materials is under investigation. In order to evaluate whether glass based materials can be used as standards it is necessary to calculate absolute values like absorption/excitation cross sections or relative quantum yields. This can be done using different quantities of dopands in glass, glass ceramics or crystals. The investigated materials are based on different types of glass, silicate, phosphate and boron glass, which play a dominant role for the absorption and emission mechanism. Additional to the so-called elementary fluorescence properties induced by raw earth elements the formation of defects lead to higher cross sections additionally. The main investigations deal with wavelength accuracy and lifetime of doped glasses, glass ceramics and crystalline samples. Moreover intensity patterns, homogeneity aspects and photo stability will be discussed. KW - Fluorescence KW - Reference material KW - Glass KW - Glass ceramics KW - Biophotonic KW - Multiplexing PY - 2006 DO - https://doi.org/10.1117/12.663627 SN - 1605-7422 VL - 6191 SP - 619110-1-619110-10 AN - OPUS4-14429 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kage, Daniel A1 - Hoffmann, Katrin A1 - Nifontova, G. A1 - Krivenkov, V. A1 - Sukhanova, A. A1 - Nabiev, I. A1 - Resch-Genger, Ute T1 - Tempo-spectral multiplexing in flow cytometry with lifetime detection using QD-encoded polymer beads N2 - Semiconductor quantum dots (QDs) embedded into polymer microbeads are known to be very attractive emitters for spectral multiplexing and colour encoding. Their luminescence lifetimes or decay kinetics have been, however, rarely exploited as encoding parameter, although they cover time ranges which are not easily accessible with other luminophores. We demonstrate here the potential of QDs made from II/VI semiconductors with luminescence lifetimes of several 10 ns to expand the lifetime range of organic encoding luminophores in multiplexing applications using time-resolved flow cytometry (LT-FCM). For this purpose, two different types of QD-loaded beads were prepared and characterized by photoluminescence measurements on the ensemble level and by single-particle confocal laser scanning microscopy. Subsequently, these lifetime-encoded microbeads were combined with dye-encoded microparticles in systematic studies to demonstrate the potential of these QDs to increase the number of lifetime codes for lifetime multiplexing and combined multiplexing in the time and colour domain (tempo-spectral multiplexing). These studies were done with a recently developed novel luminescence lifetime flow cytometer (LT-FCM setup) operating in the time-domain, that presents an alternative to reports on phase-sensitive lifetime detection in flow cytometry. KW - Fluorescence life time KW - Flow cytometry KW - Lifetime-encoded beads KW - Quantum dots KW - Multiplexing PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-503316 DO - https://doi.org/10.1038/s41598-019-56938-2 VL - 10 IS - 1 SP - Article number: 653 PB - nature.com AN - OPUS4-50331 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Engel, A. A1 - Ottermann, C. A1 - Klahn, J. A1 - Korb, T. A1 - Resch-Genger, Ute A1 - Hoffmann, Katrin A1 - Kynast, U. A1 - Rupertus, V. ED - Dan V. Nicolau, ED - Daniel L. Farkas, ED - Robert C. Leif, T1 - Anorganic fluorescence reference materials for decay time of fluorescence emission N2 - Fluorescence techniques are known for their high sensitivity and are widely used as analytical tools, detection methods and imaging applications for product and process control, material sciences, environmental and bio-technical analysis, molecular genetics, cell biology, medical diagnostics, and drug screening. According to DIN/ISO 17025 certified standards are used for steady state fluorescence diagnostics, a method having the drawback of giving relative values for fluorescence intensities only. Therefore reference materials for a quantitative characterization have to be related directly to the materials under investigation. In order to evaluate these figures it is necessary to calculate absolute numbers such as absorption/excitation cross sections and quantum yield. This has been done for different types of dopands in different materials such as glass, glass ceramics, crystals or nano crystalline material embedded in polymer matrices. Samples doped with several fluophores of different emission wavelengths and decay times are required for fluorescent multiplexing applications. Decay times shorter than 100 ns are of special interest. In addition, a proper knowledge is necessary of quantum efficiency in highly scattering media. Recently, quantum efficiency in YAG:Ce glass ceramics has been successfully investigated. Glass and glass ceramics doped with threefold charged rare earth elements are available. However, these samples have the disadvantage of emission decay times much longer than 1 microsecond, due to the excitation and emission of their optical forbidden electronic transitions. Therefore first attempts have been made to produce decay-time standards based on organic and inorganic fluophores. Stable LUMOGEN RED pigments and YAG:Ce phosphors are diluted simultaneously in silicone matrices using a wide range of concentrations between 0.0001 and 2 wt%. Organic LUMOGEN RED has decay times in the lower nanosecond range with a slight dependency on concentration and temperature. In addition, the well-known decay properties of inorganic YAG:Ce are observed also embedded in silicone matrix. Luminescent silicone layers are obtained with thicknesses between 150 and 300 m and no change of decay time, which has been determined to be between 60 and 62 ns. Finally, first results are shown for fluorescent CaF2:Pb glass ceramics embedded in a silicate glass matrix. Wavelength accuracy and lifetime are characterized for different environmental conditions such as temperature treatment and UV irradiation. Moreover, intensity patterns, e.g. line profiles and results, are discussed on homogeneity and photo and thermal stability, respectively. Fluorescence (steady state, decay time) and absorption (remission, absorption) spectroscopy are employed as diagnostic methods to get a microscopic view of the relevant physical processes. The work is funded by BMBF under project number 13N8849. KW - Fluorescence KW - Reference material KW - Glass KW - Glass ceramic KW - Phosphor KW - Doped glass and glass ceramics PY - 2008 SN - 978-0-8194-7034-8 DO - https://doi.org/10.1117/12.767633 VL - 6859 SP - 68591A-1 - 68591A-10 PB - SPIE, the International Society for Optical Engineering CY - Bellingham, Wash. AN - OPUS4-19800 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hoffmann, V. A1 - Richter, Silke T1 - Progress at the calibration of light elements N2 - Analytical glow discharges with optical (GD-OES) and mass spectrometric (GD-MS) detection are able to obtain depth resolved information about the light elements hydrogen, carbon, nitrogen and oxygen in solid samples, where most of the other analytical techniques fail. However, the interpretation or even quantification of the measured signals is still very challenging. Problems arise due to physical effects (plasma processes such as the ‘Hydrogen effect’, the Doppler effect, self absorption or diffusion of hydrogen in the sample during sputtering) chemical effects(e.g. formation of compounds with argon or the matrix, poisoning of the sample or gettering) as well as instrumental difficulties (e.g. of the sensitivity, calibration and vacuum quality).. The GD techniques are direct solid sampling methods and require reference materials for calibration. Unfortunately the list of available certified reference materials (CRM) suited for calibration of light elements in different matrix is relatively short Therefore, sintered materials doped with the analytes H2, O2 and N2 were produced at IFW Dresden and applied as calibration standards for hydrogen, oxygen and nitrogen. Due to the high analyte concentration added, it is very likely that the real concentration agree well with the added amount of light elements in the corresponding phases. The validation of the determination of the light element concentration in the sintered samples was possible in some cases only due to the lack of suitable techniques. This fact proves the need for the development of a reliable quantification of light elements by GDS. A systematic dependence of the sputtering rate on the composition was found and can be explained by basic principles. Using mixtures of TiH2 and ZrH2 with Cu the ratio of hydrogen and Cu lines has a good correlation with the corresponding concentration ratio. The hydrogen emission yield however decreases over 0.3 m% hydrogen and finally the hydrogen intensity may even decrease. This behaviour can be explained by a very similar quenching of the hydrogen and copper intensity caused by the hydrogen effect. First experiments with GD-MS show no saturation of the hydrogen ion current and thus confirm the quenching of the emission yield in GD-OES. Sintered material for the oxygen calibration (Al2O3, CuO, Cu2O and MgO mixed with Cu, Al and Mg) confirmed the blue line shift effect at O I 130.22 nm, first time reported by Köster 2009 [1]. The effect is more pronounced at Mg than in Al and Cu, which due to line interference leads to a matrix dependent EY. This effect is negligible at O I 777.19 nm and the EY is matrix independent. Using GD-MS first promising results for the calibration of oxygen with these sintered samples could be obtained, when the sputtering rate was included in the evaluation. More recently also sintered material for nitrogen calibration (AlN mixed with Al and Si3N4 mixed with Cu) was produced and points to a matrix independent emission yield of nitrogen T2 - 04 IGDSS CY - Berlin, Germany DA - 15.04.2018 KW - Glow Discharge KW - Non metals PY - 2018 AN - OPUS4-46223 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Engel, A. A1 - Ottermann, C. A1 - Klahn, J. A1 - Enseling, D. A1 - Korb, T. A1 - Resch-Genger, Ute A1 - Hoffmann, Katrin A1 - Schweizer, S. A1 - Selling, J. A1 - Kynast, U. A1 - Koberling, F. A1 - Rupertus, V. T1 - Fluorescence reference materials used for optical and biophotonic applications N2 - Fluorescence techniques are known for their high sensitivity and are widely used as analytical tools and detection methods for product and process control, material sciences, environmental and bio-technical analysis, molecular genetics, cell biology, medical diagnostics, and drug screening. According to DIN/ISO 17025 certified standards are used for fluorescence diagnostics having the drawback of giving relative values for fluorescence intensities only. Therefore reference materials for a quantitative characterization have to be related directly to the materials under investigation. In order to evaluate these figures it is necessary to calculate absolute numbers like absorption/excitation cross sections and quantum yield. This can be done for different types of dopands in different materials like glass, glass ceramics, crystals or nano crystalline material embedded in polymer matrices. Based on the optical spectroscopy data we will discuss options for characteristic doped glasses and glass ceramics with respect to scattering and absorption regime. It has shown recently for YAG:Ce glass ceramics that for a proper determination of the quantum efficiency in these highly scattering media a reference material with similar scattering and fluorescent properties is required. This may be performed using the emission decay measurement diagnostics, where the decay time is below 100 ns. In this paper we present first results of these aspects using well performing LUMOGEN RED organic pigments for a comparison of mainly transparent glass with glass ceramics doped with various amounts of dopands e.g. ions of raw earth elements and transition metals. The LUMOGEN red is embedded in silica and polyurethane matrices. Characterisations on wavelength accuracy and lifetime for different environmental conditions (temperature, UV irradiation) have been performed. Moreover intensity patterns and results for homogeneity, isotropy, photo and thermal stability will be discussed. In a next step we will show the transfer of the characterisation methods to inorganic fluophores (YAG:Ce) in silicon. Fluorescence (steady state, decay time) and absorption (remission, absorption) spectroscopy working in different temperature regimes (10 - 350 K) are employed diagnostic methods in order to get a microscopic view of the relevant physical processes and to prove the correctness of the obtained data. The work is funded by BMBF under project number 13N8849. KW - Fluorescence KW - Reference material KW - Glass KW - Glass ceramic KW - Phosphor KW - Doped glass KW - Glass ceramics PY - 2007 SN - 0-8194-6247-0 DO - https://doi.org/10.1117/12.728144 SN - 1605-7422 VL - 6628 SP - 662815-1 - 662815-9 AN - OPUS4-16729 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - You, Zengchao A1 - Hoffmann, V. A1 - Morcillo, Dalia A1 - Agudo Jácome, Leonardo A1 - Leonhardt, Robert A1 - Winckelmann, Alexander A1 - Richter, Silke A1 - Recknagel, Sebastian A1 - Abad Andrade, Carlos Enrique T1 - Investigation of aluminum current collector degradation in lithium-ion batteries using glow discharge optical emission spectrometry N2 - In this work, we employed glow discharge optical emission spectrometry (GD-OES) depth profiling as a fast and semi-quantitative method to investigate the aluminum (Al) current collector degradation in commercial lithium cobalt oxide (LCO) pouch cells with no Al2O3 pretreatment. After battery aging, a heterogeneous deposit was found on the surface of the cathode. Gray hotspot areas within an extensive pale white region were formed. Consistent with energy dispersive X-ray (EDX) analysis of micro-cross sections milled via targeted focused ion beam (FIB), an Al-containing layer of approximately 3 µm can be observed using GD-OES. We attribute one main cause of this layer is the degradation of the Al current collector. The nonuniform growth of this layer was investigated by performing GD-OES depth profiling at different in-plane positions. We found that the gray area has a higher mass concentration of Al, probably in metallic form, whereas the white area was probably covered more homogeneously with Al2O3, resulting from the inhomogeneous distribution of the pitting positions on the current collector. Compared to FIB-EDX, GD-OES enables a faster and more convenient depth profile analysis, which allows the more productive characterization of lithium-ion batteries (LIBs), and consequently benefits the development of preferable battery materials. KW - GD-OES KW - depth profiles KW - Li-ion battery KW - battery aging mechanism KW - current collector corrosion PY - 2023 DO - https://doi.org/10.1016/j.sab.2023.106681 SN - 0584-8547 VL - 205 SP - 106681 PB - Elsevier B.V. CY - Amsterdam, Netherlands AN - OPUS4-57383 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Vogel, Christian A1 - Hoffmann, Marie A1 - Krüger, O. A1 - Murzin, V. A1 - Caliebe, W. A1 - Adam, Christian T1 - Chromium (VI) in phosphorus fertilizers determined with the diffusive gradients in thin-films (DGT) technique N2 - Phosphorus (P) fertilizers from secondary resources became increasingly important in the last years. However, these novel P-fertilizers can also contain toxic pollutants such as chromium in its hexavalent state (Cr(VI)). This hazardous form of chromium is therefore regulated with low limit values for agricultural products even though the correct determination of Cr(VI) in these fertilizers may be hampered by redox processes, leading to false results. Thus, we applied the novel diffusive gradients in thin-films (DGT) technique for Cr(VI) in fertilizers and compared the results with the standard wet chemical extraction method (German norm DIN EN 15192) and Cr K-edge X-ray Absorption near-edge structure (XANES) spectroscopy. We determined an overall good correlation between the wet chemical extraction and the DGT method. DGT was very sensitive and for most tested materials selective for the analysis of Cr(VI) in P-fertilizers. However, hardly soluble Cr(VI) compounds cannot be detected with the DGT method since only mobile Cr(VI) is analyzed. Furthermore, Cr K-edge XANES spectroscopy showed that the DGT binding layer also adsorbs small amounts of mobile Cr(III) so that Cr(VI) values are overestimated. Since certain types of the P fertilizers contain mobile Cr(III) or partly immobile Cr(VI), it is necessary to optimize the DGT binding layers to avoid aforementioned over- or underestimation. Furthermore, our investigations showed that the Cr K-edge XANES spectroscopy technique is unsuitable to determine small amounts of Cr(VI) in fertilizers (below approx. 1% of Cr(VI) in relation to total Cr). KW - Phosphorus fertilizer KW - Sewage sludge ash KW - Diffusive Gradients in thin films (DGT) KW - Chemical extraction KW - XANES spectroscopy PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-509578 DO - https://doi.org/10.1007/s11356-020-08761-w SN - 0944-1344 VL - 27 SP - 24320 EP - 24328 PB - Springer AN - OPUS4-50957 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Angeli, J. A1 - Bengtson, A. A1 - Bogaerts, A. A1 - Hoffmann, V. A1 - Hodoroaba, Vasile-Dan A1 - Steers, E. T1 - Glow discharge optical emission spectrometry: moving towards reliable tion film analysis - a short review N2 - Glow discharge optical emission spectroscopy (GD-OES) is briefly reviewed, with particular reference to topics relevant to the application field of near surface and thin film analysis. The special needs and requirements for thin film analysis, in contrast to coating and bulk analysis, are pointed out. A task list is developed which shows the requirements of further developments to the technique and the fundamentals. The state-of-the-art is presented in measurement technique, GD source control and design, the effect of traces of molecular gases, correction and quantification procedures, contributions of modelling and, finally, reference materials for thin film analysis. PY - 2003 DO - https://doi.org/10.1039/b301293j SN - 0267-9477 SN - 1364-5544 VL - 18 IS - 6 SP - 670 EP - 679 PB - Royal Society of Chemistry CY - London AN - OPUS4-2533 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hoffmann, V. A1 - Dorka, R. A1 - Wilken, L. A1 - Hodoroaba, Vasile-Dan A1 - Wetzig, K. T1 - Present possibilities of thin-layer analysis by GDOES N2 - The analysis of thin layers of thickness 100 nm has become a new field of application for glow discharge optical emission spectroscopy (GDOES). In this paper an overview is given of the experiences and possibilities gained by the authors in later years at their research, development and application of GDOES. During GDOES analysis of a multilayer system the depth resolution was determined using the inverse maximal slope method. Under optimized discharge conditions a depth resolution of 25 nm at 100 nm depth was achieved. The gas flow in a Grimm-type source for glow discharge mass spectrometry (GDMS) was simulated and a correlation between calculated pressure and crater shape was found. Cleanness of the sample and source turned out to be essential for a fast stabilization time and reduction of the influence of light elements and molecules. Thereby, a 10 nm layer at the top surface of a sample could be quantified. Apart from the influence of density, the reflectivity of the sample surface is discussed. It is shown that a high sample reflectivity can cause up to 100% more light to be measured by the spectrometer. KW - GDOES KW - GDMS KW - Thin-layer analysis PY - 2003 DO - https://doi.org/10.1002/sia.1575 SN - 0142-2421 SN - 1096-9918 VL - 35 IS - 7 SP - 575 EP - 582 PB - Wiley CY - Chichester AN - OPUS4-2624 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hodoroaba, Vasile-Dan A1 - Hoffmann, V. A1 - Steers, E. B. M. T1 - Exploitation of the hydrogen effect on an analytical glow discharge T2 - Final General Meeting of the EU-GDS Network CY - Wiener Neustadt, Austria DA - 2002-03-02 PY - 2002 SP - 1(?) EP - 6(?) AN - OPUS4-1467 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gonzales-Gago, C. A1 - Smid, P. A1 - Hofmann, T. A1 - Venzago, C. A1 - Hoffmann, V. A1 - Gruner, W. A1 - Pfeifer, Jens A1 - Richter, Silke A1 - Kipphardt, Heinrich T1 - Investigations of matrix independent calibration approaches in fast flow glow discharge mass spectrometry N2 - The performance of glow discharge mass spectrometry (GD-MS) is investigated for the accurate quantification of metallic impurities and oxygen in solid samples using the fast flow source GD-MS instrument ELEMENT GD. Different quantification approaches based on relative and absolute sensitivity factors are evaluated for the determination of metallic impurities using three sample matrixes (Al, Cu and Zn). The effect of the discharge conditions (voltage, current, discharge gas pressure/flow) on the sensitivity is investigated and the parameters are optimized to favour matrix independent calibrations. Improved standard relative sensitivity factors (StdRSFs) are calculated under optimal conditions based on multi-matrix calibrations. The sputtering rate corrected calibration is also presented as a multi-matrix calibration approach. The capabilities of GD-MS for oxygen determination are also investigated using a set of new conductive samples containing oxygen with mass fractions in the percent range in three different matrices (Al, Mg and Cu) produced by a sintering process. Poor limits of detection (in the order of g/kg) were obtained as consequence of the reduced sensitivity of oxygen in GD-MS and high oxygen background signal intensity as well as its variations. The absolute sensitivity procedure is shown as a matrix-independent approach, which provides quantitative values consistent with those obtained by carrier gas hot extraction (CGHE). KW - Fast flow GD KW - GDMS KW - Calibration KW - Matrix independent calibration PY - 2019 DO - https://doi.org/10.1039/c9ja00023b SN - 1364-5544 SN - 0267-9477 VL - 34 IS - 6 SP - 1109 EP - 1125 PB - Royal Society of Chemistry CY - London AN - OPUS4-47842 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Steers, E.B.M. A1 - Hoffmann, V. A1 - Unger, Wolfgang A1 - Paatsch, Wolfgang A1 - Wetzig, K. T1 - Influence of hydrogen on the analytical figures of merit of glow discharge optical emission spectroscopy - friend or foe? PY - 2003 DO - https://doi.org/10.1039/b305384a SN - 0267-9477 SN - 1364-5544 VL - 18 SP - 521 EP - 526 PB - Royal Society of Chemistry CY - London AN - OPUS4-2290 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Steers, E.B.M. A1 - Hoffmann, V. A1 - Wetzig, K. T1 - The effect of small quantities of hydrogen on a glow discharge in neon. Comparison with the argon case N2 - In order to gain an insight into the numerous effects caused by the addition of hydrogen to an argon glow discharge, comparison experiments have been made with neon as carrier gas. In some cases the effects are diminished or even disappear. Using various bulk samples, such as copper, steel and titanium, sputtered in a neon glow discharge, the intensities of the analytical lines are affected by the presence of hydrogen in different ways from argon; the dependent parameter (the discharge current in this work) and the sputtering rate vary less than in argon. The crater shape and roughness are also affected and these effects are discussed qualitatively. Probably the most important spectral feature caused by hydrogen in the case of a discharge in argon is the emission of a continuous background. This does not appear in neon under similar discharge conditions and only weakly at high hydrogen concentrations. This supports the suggestion, made in previous work, that an effective quenching process of the argon metastables (11.55 and 11.72 eV) is Penning excitation of the hydrogen molecules, and subsequent decay to a repulsive state with emission of the continuum; in neon the energy match does not occur. It was found with neon, as with argon, that similar features occur as when hydrogen is introduced in different ways into the glow discharge: as a molecular gas contamination or as a constituent of the sample. Glow discharge mass spectrometry (GD-MS) experiments carried out with both argon and neon support the results obtained by optical emission spectrometry (OES) and provide further relevant information. PY - 2001 DO - https://doi.org/10.1039/b007527m SN - 0267-9477 SN - 1364-5544 VL - 16 SP - 43 EP - 49 PB - Royal Society of Chemistry CY - London AN - OPUS4-6887 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Hoffmann, V. A1 - Steers, E. A1 - Wetzig, K. T1 - Investigations of the emission processes in argon glow discharges containing hydrogen T2 - Winter Conference on Plasma Spectrochemistry 2000 CY - Fort Lauderdale, FL, USA DA - 2000-01-10 PY - 2000 SN - 0161-6951 VL - 25 SP - 302 EP - 303 PB - ICP Information Newsletter, Inc. CY - Amherst, Mass. AN - OPUS4-6884 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Klemm, D. A1 - Reinholz, Uwe A1 - Strub, E. A1 - Röhrich, J. A1 - Bohne, W. A1 - Hoffmann, V. A1 - Wetzig, K. T1 - Potential candidates of certified reference material for determination of hydrogen concentration with glow discharge optical emission spectrometry (GD-OES) - a feasibility study N2 - Three different coatings/layers have been found in a feasibility study as potential candidates for certified reference materials for the determination of hydrogen concentration by GD-OES: (i) electroplated zinc, (ii) carbon-rich coatings and (iii) amorphous silicon layers. KW - CRM KW - Hydrogen KW - GDS PY - 2008 DO - https://doi.org/10.1039/b717924c SN - 0267-9477 SN - 1364-5544 VL - 23 SP - 460 EP - 462 PB - Royal Society of Chemistry CY - London AN - OPUS4-17335 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Hoffmann, V. A1 - Wetzig, K. A1 - Steers, E.B.M. T1 - Investigations of the effect of hydrogen in an argon glow discharge N2 - Clear evidence of the effects caused by hydrogen, introduced in different forms in an analytical glow discharge source (GDS) operated with argon, is presented for the different matrix elements copper, stainless steel, titanium, aluminium and silicon. When hydrogen is present even in small quantities in argon, not only are there significant changes in the emission line intensities of most elements (analyte and plasma species), but also new spectral features, such as emission bands of new compounds (hydrides of sputtered sample constituents) and a continuous background in the range ~220–440 nm. Moreover, the discharge current (the dependent parameter in our experiments) decreases with increasing hydrogen concentration. Different modes of hydrogen introduction, externally in gaseous form or sputtered as a sample constituent, cause very similar effects in terms of discharge current, line intensity (of analyte and plasma gas) and emission continua, which implies similar changes in the discharge processes in the two cases. The excitation of the hydrogen continuum appears to quench the population of the argon metastables (11.55 and 11.72 eV) and, consequently, other elementary processes in the plasma in which the argon metastables take part, but to a different extent for each analyte. PY - 2000 DO - https://doi.org/10.1039/b002367l SN - 0267-9477 SN - 1364-5544 IS - 15 SP - 1075 EP - 1080 PB - Royal Society of Chemistry CY - London AN - OPUS4-964 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Hoffmann, V. A1 - Wetzig, K. A1 - Steers, E.B.M. T1 - Emission spectra of copper and argon in an argon glow discharge containing small quantities of hydrogen N2 - The influence of hydrogen contained in a sample or otherwise introduced into a glow discharge source (GDS) is here extensively experimentally presented for the case of copper as a sample by means of the addition of small quantities of molecular hydrogen (<1% relative partial pressure) to the argon carrier gas. The progressive addition of molecular hydrogen causes different intensity changes particular to the individual lines of different species such as atomic (Cu I) and ionic (Cu II) copper, and also atomic (Ar I) and ionic (Ar II) argon. Some interesting features of the emission spectrum of hydrogen such as its line, band and even continuum spectrum are observed. It was also found that the depth resolution becomes worse even at very low concentrations of hydrogen. PY - 2000 DO - https://doi.org/10.1039/b001565m SN - 0267-9477 SN - 1364-5544 IS - 15 SP - 951 EP - 958 PB - Royal Society of Chemistry CY - London AN - OPUS4-965 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Geißler, Daniel A1 - Wegmann, Marc A1 - Jochum, T. A1 - Somma, V. A1 - Sowa, M. A1 - Scholz, J. A1 - Fröhlich, E. A1 - Hoffmann, Katrin A1 - Niehaus, J. A1 - Roggenbuck, D. A1 - Resch-Genger, Ute T1 - An automatable platform for genotoxicity testing of nanomaterials based on the fluorometric γ-H2AX assay reveals no genotoxicity of properly surface-shielded cadmium-based quantum dots N2 - The large number of nanomaterial-based applications emerging in the materials and life sciences and the foreseeable increasing use of these materials require methods that evaluate and characterize the toxic potential of these nanomaterials to keep safety risks to people and environment as low as possible. As nanomaterial toxicity is influenced by a variety of parameters like size, shape, chemical composition, and surface chemistry, high throughput screening (HTS) platforms are recommended for assessing cytotoxicity. Such platforms are not yet available for genotoxicity testing. Here, we present first results obtained for application-relevant nanomaterials using an automatable genotoxicity platform that relies on the quantification of the phosphorylated histone H2AX (γ-H2AX) for detecting DNA double strand breaks (DSBs) and the automated microscope system AKLIDES® for measuring integral fluorescence intensities at different excitation wavelengths. This platform is used to test the genotoxic potential of 30 nm-sized citrate-stabilized gold nanoparticles (Au-NPs) as well as micellar encapsulated iron oxide nanoparticles (FeOx-NPs) and different cadmium (Cd)-based semiconductor quantum dots (QDs), thereby also searching for positive and negative controls as reference materials. In addition, the influence of the QD shell composition on the genotoxic potential of these Cd-based QDs was studied, using CdSe cores as well as CdSe/CdS core/shell and CdSe/CdS/ZnS core/shell/shell QDs. Our results clearly revealed the genotoxicity of the Au-NPs and its absence in the FeOx-NPs. The genotoxicity of the Cd-QDs correlates with the shielding of their Cd-containing core, with the core/shell/shell architecture preventing genotoxicity risks. The fact that none of these nanomaterials showed cytotoxicity at the chosen particle concentrations in a conventional cell viability assay underlines the importance of genotoxicity studies to assess the hazardous potential of nanomaterials. KW - Nanomaterial KW - Genotoxicity testing KW - γ-H2AX assay KW - Quantum dot PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-486318 DO - https://doi.org/10.1039/C9NR01021A SN - 2040-3372 SN - 2040-3364 VL - 11 IS - 28 SP - 13458 EP - 13468 PB - The Royal Society of Chemistry AN - OPUS4-48631 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kaufmann, Felix E.D. A1 - Hoffmann, Marie C. A1 - Bachmann, Kai A1 - Veksler, Ilya V. A1 - Trumbull, Robert B. A1 - Hecht, Lutz T1 - Variations in composition, texture, and platinum group element mineralization in the lower group and middle group chromitites of the Northwestern Bushveld Complex, South Africa N2 - Small-scale variations in mineral chemistry, textures, and platinum group element (PGE) mineralization were investigated in the Lower and Middle Group chromitite layers LG6, LG6a, MG1, MG2, and MG2 II from vertical drill core profiles at the Thaba mine in the northwestern limb of the Bushveld Complex. We present detailed geochemical profiles of chromite composition and chromite crystal size distribution curves to shed light on the processes of chromite accumulation and textural modification as well as mineralization. Multiple samples within each layer were assayed for PGE concentrations, and the respective platinum group mineral association was determined by mineral liberation analysis (MLA). There is strong evidence for postcumulus changes in the chromitites. The crystal size distribution curves suggest that the primary chromite texture was coarsened by a combination of adcumulus growth and textural equilibration, while compaction of the crystal mush played only a minor role. Mineral compositions were also modified by postcumulus processes, but because of the very high modal amount of chromite and its local preservation in orthopyroxene oikocrysts, that phase retained much primary information. Vertical variations of chromite composition within chromitite layers and from one layer to another do not support the idea of chromite accumulation from crystal-rich slurries or crystal settling from a large magma chamber. Instead, we favor a successive buildup of chromitite layers by repeated injections of relatively thin layers of chromite-saturated magmas, with in situ crystallization occurring at the crystal mush-magma interface. The adcumulus growth of chromite grains to form massive chromitite required addition of Cr to the layers, which we attribute to downward percolation from the overlying magma. The PGE concentrations are elevated in all chromitite layers compared to adjacent silicate rocks and show a systematic increase upward from LG6 (avg 807 ppb Ir + Ru + Rh + Pt + Pd + Au) to MG2 II (avg 2,062 ppb). There are also significant internal variations in all layers, with enrichments at hanging and/or footwalls. The enriched nature of chromitites in PGEs compared to host pyroxenites is a General feature, independent of the layer thickness. The MLA results distinguish two principal groups of PGE mineral associations: the LG6, LG6, and MG1 are dominated by the malanite series, laurite, and PGE sulfarsenides, while the MG2 and MG2 II layers are characterized by laurite and PGE sulfides as well as Pt-Fe-Sn and PGE-Sb-Bi-Pb alloys. Differences in the PGE associations are attributed to postcumulus alteration of the MG2 and MG2 II layer, while the chromitites below, particularly LG6 and LG6a, contain a more pristine association. KW - Bushveld Complex KW - Chromitites KW - Platinum PY - 2019 DO - https://doi.org/10.5382/econgeo.4641 SN - 0361-0128 VL - 114 IS - 3 SP - 569 EP - 590 PB - Society of Economic Geologists AN - OPUS4-48145 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Hoffmann, V. A1 - Wetzig, K. A1 - Steers, E. T1 - ThP33 Investigations of the emission processes in argon glow discharges containing hydrogen T2 - Winter Conference on Plasma Spectrochemistry 2000 CY - Fort Lauderdale, FL, USA DA - 2000-01-10 PY - 2000 SN - 0161-6951 VL - 25 SP - 1 EP - 2 PB - ICP Information Newsletter, Inc. CY - Amherst, Mass. AN - OPUS4-846 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hoffmann, V. T1 - Tiefenprofilanalytik mittels Glimmentladungsspektrometrie von nichtleitenden Schichtsystemen T2 - AOFA12 CY - Kaiserslautern, Germany DA - 2002-09-15 PY - 2002 AN - OPUS4-6242 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Hoffmann, V. A1 - Steers, E.B.M. A1 - Griepentrog, Michael A1 - Dück, Alexander A1 - Beck, Uwe T1 - Round Robin exercise: Coated materials for glow discharge spectroscopy N2 - A Round Robin (RR) exercise on selected coated materials has been carried out with the aim of finding the optimal conditions for the analysis of nitride layers with GD-OES. Such pre-normative work is necessary for the evaluation of parallel development of the production of nitride layers as certified reference materials (CRMs). Two types of samples, Ti–N layer and V–N layer, respectively, with chemical compositions close to stoichiometry and a thickness of ~3 µm, deposited on a steel substrate, have been provided to the RR participants. Additionally, another type of sample, a (100 nm CrNi/100 nm Cu) multilayer (ML) stack deposited on silicon wafer has also been included in the RR. This sample can be used as a CRM for checking GD spectrometer conditions and it has been proved helpful in further development of GDS instrumentation and methodology. The RR exercise has been performed in the frame of the EC Thematic Network on Glow Discharge Spectroscopy for Spectrochemical Analysis (‘GDS-Net’). KW - Coated/Layered Reference Materials KW - Nitrides KW - Multilayer KW - GDS KW - Round Robin PY - 2006 DO - https://doi.org/10.1039/B513426A SN - 0267-9477 SN - 1364-5544 VL - 21 IS - 1 SP - 74 EP - 81 PB - Royal Society of Chemistry CY - London AN - OPUS4-11762 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Unger, Wolfgang A1 - Jenett, H. A1 - Hoffmann, V. A1 - Hagenhoff, B. A1 - Kayser, S. A1 - Wetzig, K. T1 - Depth profiling of electrically non-conductive layered samples by RF-GDOES and HFM plasma SNMS N2 - The work is intended to compare the capabilities of two similar depth profiling techniques to analyse electrically non-conductive samples. In order to get a better evaluation of the depth resolution, various multilayer sandwiches, such as SiO2/TiO2 and Si3N4/SiO2 deposited on glass substrates have been investigated. Optimised depth profiles are presented for both methods, glow discharge optical emission spectrometry (GDOES) and radiofrequency mode (known as “HFM” in the SNMS literature) of plasma secondary neutral mass spectrometry (SNMS). The optimisation procedure, necessary to get the best set of plasma parameters, which result in the optimal depth resolution, is also described for one selected sample. Additionally, sputtering crater profilometry was carried out in order to check out the flatness of the sputtered crater. The influence of the thickness of the sample substrate on the sputtering rate is discussed. Finally, advantages and disadvantages of the use of these two depth profiling methods, especially for the non-conductive samples, are concluded from this comparative study. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) analysis of a cross-sectioned sample was carried out in order to get supplementary information. KW - rf-Glow discharge KW - HFM plasma SNMS KW - Non-conductive layered samples KW - Depth resolution KW - Crater shape KW - ToF-SIMS PY - 2001 DO - https://doi.org/10.1016/S0169-4332(01)00259-8 SN - 0169-4332 SN - 1873-5584 VL - 179 IS - 1-4 SP - 30 EP - 37 PB - North-Holland CY - Amsterdam AN - OPUS4-6882 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Hoffmann, V. A1 - Steers, E. B. M. A1 - Wetzig, K. T1 - Exploitation of the effect of hydrogen on an analytical glow discharge T2 - Winter Conference on Plasma Spectrochemistry 2002 CY - Scottsdale, AZ, USA DA - 2002-01-06 PY - 2002 SN - 0161-6951 SP - 261 EP - 262 PB - ICP Information Newsletter, Inc. CY - Amherst, Mass. AN - OPUS4-1589 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Glauber, J.-P. A1 - Lorenz, J. A1 - Liu, J. A1 - Seifert, M. A1 - Hoffmann, V. A1 - Abad Andrade, Carlos Enrique A1 - Rogalla, D. A1 - Harms, C. A1 - Wark, M. A1 - Nolan, M. A1 - Devi, A. T1 - High Quality Crystalline VN Thin Films via MOCVD from a New Vanadium Precursor: Linking Growth Chemistry to Functional Catalytic Surfaces N2 - Vanadium nitride (VN) has been identified as a promising material for numerous applications including electrochemical nitrogen reduction reaction (eNRR). For such applications, catalyst nanoengineering will help to experimentally test its theoretically predicted eNRR activity, but the majority of investigated VN catalysts are prepared by fabrication methods that do not allow for nanoengineering to the required degree. Herein, we report on a new metalorganic chemical vapor deposition (MOCVD) process for the growth of high quality, facetted and crystalline VN thin films relevant for eNRR applications. N,N’-diisopropylformamidinato [V(dpfamd)3] was identified as a promising precursor as it possesses favorable thermal properties relevant for MOCVD. The application of [V(dpfamd)3] in a MOCVD process with NH3 as co-reactant yielded crystalline VN thin films on Si substrates with high compositional purity. With the potential of using the catalytic activity of VN towards eNRR, the structure-property correlation is of relevance and in this context, the thin films were subjected to complementary analysis including X-ray diffraction (XRD), Rutherford backscattering spectrometry in combination with nuclear reaction analysis (RBS/NRA), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and transmission electron microscopy (TEM). Based on the observation of the significant influence NH3 has on the growth characteristics, we conducted first principles density functional theory (DFT) simulations of the precursor reactivity in the absence and presence of NH3 towards VN, supporting experimental findings of energetically more favorable decomposition of [V(dpfamd)3] to VN in the presence of NH3. Process transfer from Si to conductive Ti substrates, relevant for prospective electrochemical testing, revealed comparable VN thin film properties rendering these films promising for further investigation of eNRR applications in follow up studies. KW - Metal nitrades KW - MOCVD KW - Nitrogen reduction reaction KW - Precursors KW - DFT PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-648600 DO - https://doi.org/10.26434/chemrxiv-2025-1t4gq SP - 1 EP - 25 AN - OPUS4-64860 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gomes, Bruna F. A1 - Prokop, Martin A1 - Bystron, Tomas A1 - Loukrakpam, Rameshwori A1 - Melke, Julia A1 - Lobo, Carlos M. S. A1 - Fink, Michael A1 - Zhu, Mengshu A1 - Voloshina, Elena A1 - Kutter, Maximilian A1 - Hoffmann, Hendrik A1 - Yusenko, Kirill V. A1 - de Oliveira Guilherme Buzanich, Ana A1 - Röder, Bettina A1 - Bouzek, Karel A1 - Paulus, Beate A1 - Roth, Christina T1 - Following Adsorbed Intermediates on a Platinum Gas Diffusion Electrode in H3PO3-Containing Electrolytes Using In Situ X-ray Absorption Spectroscopy N2 - One of the challenges of high-temperature polymer electrolyte membrane fuel cells is the poisoning of the Pt catalystwith H3PO4. H3PO4 is imbibed into the routinely used polybenzimidazole-based membranes, which facilitate Proton conductivity in the temperature range of 120−200 °C. However, when leached out of the membrane by water produced during operation, H3PO4 adsorbs on the Pt catalyst surface, blocking the active sites and hindering the oxygen reduction reaction (ORR). The reduction of H3PO4 to H3PO3, which occurs at the anode due to a combination of a low potential and the presence of gaseous H2, has been investigated as an additional important contributing factor to the observed poisoning effect. H3PO3 has an affinity toward adsorption on Pt surfaces even greater than that of H2PO4 −. In this work, we investigated the poisoning effect of both H3PO3 and H3PO4 using a half-cell setup with a gas diffusion electrode under ambient conditions. By means of in situ X-ray absorption spectroscopy, it was possible to follow the signature of different species adsorbed on the Pt nanoparticle catalyst (H, O, H2PO4 −, and H3PO3) at different potentials under ORR conditions in various electrolytes (HClO4, H3PO4, and H3PO3). It was found that H3PO3 adsorbs in a pyramidal configuration P(OH)3 through a Pt−P bond. The competition between H3PO4 and H3PO3 adsorption was studied, which should allow for a better understanding of the catalyst poisoning mechanism and thus assist in the development of strategies to mitigate this phenomenon in the future by minimizing H3PO3 generation by, for example, improved catalyst design or adapted operation conditions or changes in the electrolyte composition. KW - H3PO4 life cycle KW - XAS KW - In situ coupling KW - High-temperature fuel cells KW - H3PO3, KW - Δμ XANES PY - 2022 DO - https://doi.org/10.1021/acscatal.2c02630 SN - 2155-5435 VL - 12 IS - 18 SP - 11472 EP - 11484 PB - American Chemical Society (ACS) AN - OPUS4-64733 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -