TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Hoffmann, V. A1 - Steers, E. B. M. A1 - Wetzig, K. T1 - Exploitation of the effect of hydrogen on an analytical glow discharge T2 - Winter Conference on Plasma Spectrochemistry 2002 CY - Scottsdale, AZ, USA DA - 2002-01-06 PY - 2002 SN - 0161-6951 SP - 261 EP - 262 PB - ICP Information Newsletter, Inc. CY - Amherst, Mass. AN - OPUS4-1589 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Grunert, B. A1 - Saatz, Jessica A1 - Hoffmann, Katrin A1 - Appler, F. A1 - Lubjuhn, Dominik A1 - Jakubowski, Norbert A1 - Resch-Genger, Ute A1 - Emmerling, Franziska A1 - Briel, A. T1 - Multifunctional rare-earth element nanocrystals for cell labeling and multimodal imaging N2 - In this work, we describe a simple solvothermal route for the synthesis of Eu3+-doped gadolinium orthovanadate nanocrystals (Eu:GdVO4−PAA) functionalized with poly(acrylic)acid (PAA), that are applicable as cell labeling probes for multimodal cellular imaging. The Eu3+ doping of the vanadate matrix provides optical functionality, due to red photoluminescence after illumination with UV light. The Gd3+ ions of the nanocrystals reduce the T1 relaxation time of surrounding water protons, allowing these nanocrystals to act as a positive MRI contrast agent with a r1 relaxivity of 1.97 mM−1 s−1. Low background levels of Eu3+, Gd3+, and V5+ in biological systems make them an excellent label for elemental microscopy by Laser Ablation (LA)-ICP-MS. Synthesis resulted in polycrystalline nanocrystals with a hydrodynamic diameter of 55 nm and a crystal size of 36.7 nm, which were further characterized by X-ray diffraction (XRD), photoluminescence spectroscopy (PL) and transmission electron microscopy (TEM). The multifunctional nanocrystals were subsequently used for intracellular labeling of both human adipose-derived stem cells (MSCs) and A549 (adenocarcinomic human alveolar basal epithelial) cells. KW - Bioimaging KW - Nanoparticle KW - Multimodal KW - Lanthanide PY - 2018 DO - https://doi.org/10.1021/acsbiomaterials.8b00495 SN - 2373-9878 VL - 4 IS - 10 SP - 3578 EP - 3587 PB - ACS Publications CY - Washington, USA AN - OPUS4-46244 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Steers, E.B.M. A1 - Hoffmann, V. A1 - Unger, Wolfgang A1 - Paatsch, Wolfgang A1 - Wetzig, K. T1 - Influence of hydrogen on the analytical figures of merit of glow discharge optical emission spectroscopy - friend or foe? PY - 2003 DO - https://doi.org/10.1039/b305384a SN - 0267-9477 SN - 1364-5544 VL - 18 SP - 521 EP - 526 PB - Royal Society of Chemistry CY - London AN - OPUS4-2290 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Steers, E.B.M. A1 - Hoffmann, V. A1 - Wetzig, K. T1 - The effect of small quantities of hydrogen on a glow discharge in neon. Comparison with the argon case N2 - In order to gain an insight into the numerous effects caused by the addition of hydrogen to an argon glow discharge, comparison experiments have been made with neon as carrier gas. In some cases the effects are diminished or even disappear. Using various bulk samples, such as copper, steel and titanium, sputtered in a neon glow discharge, the intensities of the analytical lines are affected by the presence of hydrogen in different ways from argon; the dependent parameter (the discharge current in this work) and the sputtering rate vary less than in argon. The crater shape and roughness are also affected and these effects are discussed qualitatively. Probably the most important spectral feature caused by hydrogen in the case of a discharge in argon is the emission of a continuous background. This does not appear in neon under similar discharge conditions and only weakly at high hydrogen concentrations. This supports the suggestion, made in previous work, that an effective quenching process of the argon metastables (11.55 and 11.72 eV) is Penning excitation of the hydrogen molecules, and subsequent decay to a repulsive state with emission of the continuum; in neon the energy match does not occur. It was found with neon, as with argon, that similar features occur as when hydrogen is introduced in different ways into the glow discharge: as a molecular gas contamination or as a constituent of the sample. Glow discharge mass spectrometry (GD-MS) experiments carried out with both argon and neon support the results obtained by optical emission spectrometry (OES) and provide further relevant information. PY - 2001 DO - https://doi.org/10.1039/b007527m SN - 0267-9477 SN - 1364-5544 VL - 16 SP - 43 EP - 49 PB - Royal Society of Chemistry CY - London AN - OPUS4-6887 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Hoffmann, V. A1 - Wetzig, K. A1 - Steers, E.B.M. T1 - Investigations of the effect of hydrogen in an argon glow discharge N2 - Clear evidence of the effects caused by hydrogen, introduced in different forms in an analytical glow discharge source (GDS) operated with argon, is presented for the different matrix elements copper, stainless steel, titanium, aluminium and silicon. When hydrogen is present even in small quantities in argon, not only are there significant changes in the emission line intensities of most elements (analyte and plasma species), but also new spectral features, such as emission bands of new compounds (hydrides of sputtered sample constituents) and a continuous background in the range ~220–440 nm. Moreover, the discharge current (the dependent parameter in our experiments) decreases with increasing hydrogen concentration. Different modes of hydrogen introduction, externally in gaseous form or sputtered as a sample constituent, cause very similar effects in terms of discharge current, line intensity (of analyte and plasma gas) and emission continua, which implies similar changes in the discharge processes in the two cases. The excitation of the hydrogen continuum appears to quench the population of the argon metastables (11.55 and 11.72 eV) and, consequently, other elementary processes in the plasma in which the argon metastables take part, but to a different extent for each analyte. PY - 2000 DO - https://doi.org/10.1039/b002367l SN - 0267-9477 SN - 1364-5544 IS - 15 SP - 1075 EP - 1080 PB - Royal Society of Chemistry CY - London AN - OPUS4-964 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Hoffmann, V. A1 - Wetzig, K. A1 - Steers, E.B.M. T1 - Emission spectra of copper and argon in an argon glow discharge containing small quantities of hydrogen N2 - The influence of hydrogen contained in a sample or otherwise introduced into a glow discharge source (GDS) is here extensively experimentally presented for the case of copper as a sample by means of the addition of small quantities of molecular hydrogen (<1% relative partial pressure) to the argon carrier gas. The progressive addition of molecular hydrogen causes different intensity changes particular to the individual lines of different species such as atomic (Cu I) and ionic (Cu II) copper, and also atomic (Ar I) and ionic (Ar II) argon. Some interesting features of the emission spectrum of hydrogen such as its line, band and even continuum spectrum are observed. It was also found that the depth resolution becomes worse even at very low concentrations of hydrogen. PY - 2000 DO - https://doi.org/10.1039/b001565m SN - 0267-9477 SN - 1364-5544 IS - 15 SP - 951 EP - 958 PB - Royal Society of Chemistry CY - London AN - OPUS4-965 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hoffmann, H A1 - Paulisch, M C A1 - Gebhard, M A1 - Osiewacz, J A1 - Kutter, M A1 - Hilger, A A1 - Arlt, T A1 - Kardjilov, N A1 - Ellendorff, B A1 - Beckmann, F A1 - Markötter, Henning A1 - Luik, M A1 - Turek, T A1 - Manke, I A1 - Roth, C T1 - Development of a Modular Operando Cell for X-ray Imaging of Strongly Absorbing Silver-Based Gas Diffusion Electrodes N2 - Metal-based gas diffusion electrodes are utilized in chlor-alkali electrolysis or electrochemical reduction of carbon dioxide, allowing the reaction to proceed at high current densities. In contrast to planar electrodes and predominantly 2D designs, the industrially required high current densities can be achieved by intense contact between the gas and liquid phase with the catalytically active surfaces. An essential asset for the knowledge-based design of tailored electrodes is therefore in-depth information on electrolyte distribution and intrusion into the electrode’s porous structure. Lab-based and synchrotron radiography allow for monitoring this process operando. Herein, we describe the development of a cell design that can be modularly adapted and successfully used to monitor both the oxygen reduction reaction and the electrochemical reduction of CO2 as exemplary and currently very relevant examples of gas-liquid reactions by only minor modifications to the cell set-up. With the reported cell design, we were able to observe the electrolyte distribution within the gas diffusion electrode during cell operation in realistic conditions. KW - X-Ray imaging KW - Gas diffusion electrodes KW - Operando cell PY - 2022 DO - https://doi.org/10.1149/1945-7111/ac6220 VL - 169 IS - 4 SP - 044508 PB - IOP science AN - OPUS4-55027 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Hoffmann, V. A1 - Steers, E.B.M. A1 - Griepentrog, Michael A1 - Dück, Alexander A1 - Beck, Uwe T1 - Round Robin exercise: Coated materials for glow discharge spectroscopy N2 - A Round Robin (RR) exercise on selected coated materials has been carried out with the aim of finding the optimal conditions for the analysis of nitride layers with GD-OES. Such pre-normative work is necessary for the evaluation of parallel development of the production of nitride layers as certified reference materials (CRMs). Two types of samples, Ti–N layer and V–N layer, respectively, with chemical compositions close to stoichiometry and a thickness of ~3 µm, deposited on a steel substrate, have been provided to the RR participants. Additionally, another type of sample, a (100 nm CrNi/100 nm Cu) multilayer (ML) stack deposited on silicon wafer has also been included in the RR. This sample can be used as a CRM for checking GD spectrometer conditions and it has been proved helpful in further development of GDS instrumentation and methodology. The RR exercise has been performed in the frame of the EC Thematic Network on Glow Discharge Spectroscopy for Spectrochemical Analysis (‘GDS-Net’). KW - Coated/Layered Reference Materials KW - Nitrides KW - Multilayer KW - GDS KW - Round Robin PY - 2006 DO - https://doi.org/10.1039/B513426A SN - 0267-9477 SN - 1364-5544 VL - 21 IS - 1 SP - 74 EP - 81 PB - Royal Society of Chemistry CY - London AN - OPUS4-11762 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -