TY - JOUR A1 - Schmidt, Stephan A1 - Hoffmann, Holger A1 - Garbe, Leif-Alexander A1 - Harrer, Andrea A1 - Steiner, Markus A1 - Himly, Martin A1 - Schneider, Rudolf T1 - Re-assessment of monoclonal antibodies against diclofenac for their application in the analysis of environmental waters N2 - The non-steroidal anti-inflammatory drug (NSAID) diclofenac (DCF) is an important environmental contaminant occurring in surface waters all over the world, because, after excretion, it is not adequately removed from wastewater in sewage treatment plants. To be able to monitor this pollutant, highly efficient analytical methods are needed, including immunoassays. In a medical research project, monoclonal antibodies against diclofenac and its metabolites had been produced. Based on this monoclonal anti-DCF antibody, a new indirect competitive enzyme-linked immunosorbent assay (ELISA) was developed and applied for environmental samples. The introduction of a spacer between diclofenac and the carrier protein in the coating conjugate led to higher sensitivity. With a test midpoint of 3 mg L−1 and a measurement range of 1–30 mg L−1, the system is not sensitive enough for direct analysis of surface water. However, this assay is quite robust against matrix influences and can be used for wastewater. Without adjustment of the calibration, organic solvents up to 5%, natural organic matter (NOM) up to 10 mg L−1, humic acids up to 2.5 mg L−1, and salt concentrations up to 6 g L−1 NaCl and 75 mg L−1 CaCl2 are tolerated. The antibody is also stable in a pH range from 3 to 12. Cross-reactivity (CR) of 1% or less was determined for the metabolites 40-hydroxydiclofenac (40-OH-DCF), 5-hydroxydiclofenac (5-OH-DCF), DCF lactam, and other NSAIDs. Relevant cross-reactivity occurred only with an amide derivative of DCF, 6-aminohexanoic acid (DCF-Ahx), aceclofenac (ACF) and DCF methyl ester (DCF-Me) with 150%, 61% and 44%, respectively. These substances, however, have not been found in samples. Only DCF-acyl glucuronide with a cross-reactivity of 57% is of some relevance. For the first time, photodegradation products were tested for cross-reactivity. With the ELISA based on this antibody, water samples were analysed. In sewage treatment plant effluents, concentrations in the range of 1.9–5.2 mg L−1 were determined directly, with recoveries compared to HPLC-MS/MS averaging 136%. Concentrations in lakes ranged from 3 to 4.4 ng L−1 and were, after pre-concentration, determined with an average recovery of 100% KW - Antikörper KW - Immunoassay KW - Wasser PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-602280 DO - https://doi.org/10.1039/d3ay01333b VL - 16 IS - 21 SP - 3349 EP - 3363 PB - Royal Society of Chemistry (RSC) CY - London AN - OPUS4-60228 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Deppe, Hans-Joachim A1 - Hoffmann, Alexander T1 - Zur Verwendung von Catole-Palme für die Herstellung von Spanplatten PY - 1977 SN - 0018-3768 VL - 35 SP - 91 EP - 94 PB - Springer CY - Berlin AN - OPUS4-8722 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Deppe, Hans-Joachim A1 - Hoffmann, Alexander T1 - Germany's BAM Tests Catole Palm Wood, Finds it Can Make Good Particleboard PY - 1977 SN - 0043-9258 VL - 18 SP - 36 EP - 37 CY - San Francisco, Calif. AN - OPUS4-8723 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Poelke, Birte A1 - Klein, Luise A1 - Rohloff, Alexander A1 - Hoffmann, Holger T1 - Initial VOC Emissions from Consumer Products Determined in Micro-Scale Test Chambers: Results of a Round Robin Test N2 - Emissions of volatile organic compounds (VOCs) from consumer products may have a negative impact on indoor air quality, potentially also affecting human wellbeing. Since consumers may be exposed to these VOCs immediately after e.g. unwrapping of newly purchased products, reliable analytical methods are needed to determine air concentration profiles in the early phase of VOC emissions. Concerning typical sample sizes of consumer products, micro-scale test chambers (μ-chambers) were considered suitable for this purpose. In addition, compared to medium- or large-scale test chambers, μ-chambers require lower initial investment and operational costs, and offer options for emissions screenings where higher sample throughput is essential. For these reasons, a μ-chamber-based method to determine initial concentrations of VOCs emitting within the first hours of simulated product use was developed. The chamber air was frequently sampled on desorption tubes loaded with Tenax® TA, followed by quantification of emitted VOCs via thermal desorption gas chromatography mass spectrometry (TD-GC-MS). The method was assessed in a round robin test involving eight participating laboratories from 2 countries. Pieces of a rain poncho (sample area A: 2.01·10-4 m2) emitting cyclohexanone, phenol, 2-ethylhexanol, naphthalene and isophorone in significant concentrations were distributed as sample material. Each laboratory conducted triplicate emission tests over a period of 48 h in μ-chambers with volumes of 44 or 114 mL. The loading factors L of 4.57 m2·m-3 (44 mL) or 1.76 m2·m-3 (114 mL) and air flow rates of 24 mL·min-1 resulted in area-specific air flow rates q of 7.17 m3·m-2·h-1 in both chamber types. The temperature was set to 23°C and, if possible, relative humidity was set to approx. 50%. The chamber air was sampled after 0.5, 1, 2, 4, 24 and 48 hours. In addition, to assess the analytical performance, each participating laboratory received two analyte-spiked Tenax® TA-loaded desorption tubes for quality control (QC). Very low relative standard deviations (11–17%) were obtained for the QC test. The results of the emissions tests in the early phase (0.5–4 h) were also adequate, with acceptable z scores (|z|≤2.00) received by six to seven participating laboratories. All eight laboratories obtained acceptable z scores after the longer sampling periods (24 and 48 h). Hence, the inter-laboratory comparability of the results obtained with the developed μ-chamber method was successfully confirmed. T2 - Healthy Buildings Europe 2025 CY - Reykjavik, Iceland DA - 08.06.2025 KW - VOC Emissions KW - Consumer Product KW - Test Chamber KW - Round Robin Test PY - 2025 AN - OPUS4-63706 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Chan, George C.-Y. A1 - Hieftje, Gary M. A1 - Omenetto, Nicoló A1 - Axner, Ove A1 - Bengtson, Arne A1 - Bings, Nicolas H. A1 - Blades, Michael W. A1 - Bogaerts, Annemie A1 - Bolshov, Mikhail A. A1 - Broekaert, José A.C. A1 - Chan, WingTat A1 - Costa-Fernández, José M. A1 - Crouch, Stanley R. A1 - De Giacomo, Alessandro A1 - D’Ulivo, Alessandro A1 - Engelhard, Carsten A1 - Falk, Heinz A1 - Farnsworth, Paul B. A1 - Florek, Stefan A1 - Gamez, Gerardo A1 - Gornushkin, Igor B. A1 - Günther, Detlef A1 - Hahn, David W. A1 - Hang, Wei A1 - Hoffmann, Volker A1 - Jakubowski, Norbert A1 - Karanassios, Vassili A1 - Koppenaal, David W. A1 - Kenneth Marcus, R. A1 - Noll, Reinhard A1 - Olesik, John W. A1 - Palleschi, Vincenzo A1 - Panne, Ulrich A1 - Pisonero, Jorge A1 - Ray, Steven J. A1 - Resano, Martín A1 - Russo, Richard E. A1 - Scheeline, Alexander A1 - Smith, Benjamin W. A1 - Sturgeon, Ralph E. A1 - Todolí, José-Luis A1 - Tognoni, Elisabetta A1 - Vanhaecke, Frank A1 - Webb, Michael R. A1 - Winefordner, James D. A1 - Yang, Lu A1 - Yu, Jin A1 - Zhang, Zhanxia T1 - Landmark Publications in Analytical Atomic Spectrometry: Fundamentals and Instrumentation Development N2 - The almost-two-centuries history of spectrochemical analysis has generated a body of literature so vast that it has become nearly intractable for experts, much less for those wishing to enter the field. Authoritative, focused reviews help to address this problem but become so granular that the overall directions of the field are lost. This broader perspective can be provided partially by general overviews but then the thinking, experimental details, theoretical underpinnings and instrumental innovations of the original work must be sacrificed. In the present compilation, this dilemma is overcome by assembling the most impactful publications in the area of analytical atomic spectrometry. Each entry was proposed by at least one current expert in the field and supported by a narrative that justifies its inclusion. The entries were then assembled into a coherent sequence and returned to contributors for a round-robin review. KW - Analytical atomic spectrometry KW - Spectroscopy KW - Instrumental analysis PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-621588 DO - https://doi.org/10.1177/00037028241263567 SN - 1943-3530 VL - 78 SP - 1 EP - 456 PB - Sage CY - London AN - OPUS4-62158 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schlögl, Johanna A1 - Krappe, Alexander R. A1 - Fürstenwerth, Paul C. A1 - Brosius, Amelie L. A1 - Fasting, Carlo A1 - Hoffmann, Kurt F. A1 - Resch-Genger, Ute A1 - Eigler, Siegfried A1 - Steinhauer, Simon A1 - Riedel, Sebastian T1 - Luminescent Perhalofluoro Trityl Radicals N2 - In this proof-of-concept study, we show that polyfluorinated trityl radicals with the, to this date, highest fluorination grade can be accessed in quantitative yields in a straightforward manner starting from the perfluorinated trityl cation. The trityl skeleton is functionalized with trimethylsilyl halides to yield perhalofluoro trityl cations, which are subsequently reduced using commercial zinc powder. In this way, we prepare three perhalofluoro trityl radicals and analyze the impact of the fluorine ligands on their electro-optical properties, revealing some interesting trends. In comparison to literature-known polychlorinated trityl radicals, the new polyfluorinated derivatives exhibit substantially higher fluorescence quantum yields, longer luminescence lifetimes, and an expanded emission range that extends into the yellow spectral region. They further display enhanced photostability under light irradiation. In radical-stained polystyrene nanoparticles, an additional broad emission band in the red−NIR wavelength region is observed, which is attributed to excimer formation. Finally, the stability of the new radicals is investigated under ambient conditions, showing the slow conversion with atmospheric oxygen yielding the respective peroxides, which are characterized by single-crystal X-ray diffraction. All in all, our study extends the present scope of luminescent trityl radicals, as the functionalization of the perfluorinated cationic precursor unlocks the path toward a vast variety of polyfluorinated trityl radicals. KW - Dye KW - Fluorescence KW - Radical KW - Synthesis KW - Mechanism KW - Signal enhancement KW - Nano KW - Particle KW - Characterization KW - Quantum yield KW - Photophysics KW - Lifetime KW - Polarity KW - Polymer KW - Solvatchromism KW - Excimer PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-647973 DO - https://doi.org/10.1021/jacs.5c16418 SN - 0002-7863 VL - 147 IS - 46 SP - 1 EP - 8 PB - American Chemical Society (ACS) AN - OPUS4-64797 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - You, Zengchao A1 - Hoffmann, V. A1 - Morcillo, Dalia A1 - Agudo Jácome, Leonardo A1 - Leonhardt, Robert A1 - Winckelmann, Alexander A1 - Richter, Silke A1 - Recknagel, Sebastian A1 - Abad Andrade, Carlos Enrique T1 - Investigation of aluminum current collector degradation in lithium-ion batteries using glow discharge optical emission spectrometry N2 - In this work, we employed glow discharge optical emission spectrometry (GD-OES) depth profiling as a fast and semi-quantitative method to investigate the aluminum (Al) current collector degradation in commercial lithium cobalt oxide (LCO) pouch cells with no Al2O3 pretreatment. After battery aging, a heterogeneous deposit was found on the surface of the cathode. Gray hotspot areas within an extensive pale white region were formed. Consistent with energy dispersive X-ray (EDX) analysis of micro-cross sections milled via targeted focused ion beam (FIB), an Al-containing layer of approximately 3 µm can be observed using GD-OES. We attribute one main cause of this layer is the degradation of the Al current collector. The nonuniform growth of this layer was investigated by performing GD-OES depth profiling at different in-plane positions. We found that the gray area has a higher mass concentration of Al, probably in metallic form, whereas the white area was probably covered more homogeneously with Al2O3, resulting from the inhomogeneous distribution of the pitting positions on the current collector. Compared to FIB-EDX, GD-OES enables a faster and more convenient depth profile analysis, which allows the more productive characterization of lithium-ion batteries (LIBs), and consequently benefits the development of preferable battery materials. KW - GD-OES KW - depth profiles KW - Li-ion battery KW - battery aging mechanism KW - current collector corrosion PY - 2023 DO - https://doi.org/10.1016/j.sab.2023.106681 SN - 0584-8547 VL - 205 SP - 106681 PB - Elsevier B.V. CY - Amsterdam, Netherlands AN - OPUS4-57383 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Hoffmann, V. A1 - Steers, E.B.M. A1 - Griepentrog, Michael A1 - Dück, Alexander A1 - Beck, Uwe T1 - Round Robin exercise: Coated materials for glow discharge spectroscopy N2 - A Round Robin (RR) exercise on selected coated materials has been carried out with the aim of finding the optimal conditions for the analysis of nitride layers with GD-OES. Such pre-normative work is necessary for the evaluation of parallel development of the production of nitride layers as certified reference materials (CRMs). Two types of samples, Ti–N layer and V–N layer, respectively, with chemical compositions close to stoichiometry and a thickness of ~3 µm, deposited on a steel substrate, have been provided to the RR participants. Additionally, another type of sample, a (100 nm CrNi/100 nm Cu) multilayer (ML) stack deposited on silicon wafer has also been included in the RR. This sample can be used as a CRM for checking GD spectrometer conditions and it has been proved helpful in further development of GDS instrumentation and methodology. The RR exercise has been performed in the frame of the EC Thematic Network on Glow Discharge Spectroscopy for Spectrochemical Analysis (‘GDS-Net’). KW - Coated/Layered Reference Materials KW - Nitrides KW - Multilayer KW - GDS KW - Round Robin PY - 2006 DO - https://doi.org/10.1039/B513426A SN - 0267-9477 SN - 1364-5544 VL - 21 IS - 1 SP - 74 EP - 81 PB - Royal Society of Chemistry CY - London AN - OPUS4-11762 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -