TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. T1 - X-Ray refraction computed tomography for NDE of lightweight materials T2 - Deutsche Tagung für Forschung mit Synchrotronstrahlung, Neutronen und Ionenstrahlen an Großgeräten 2006 (SNI2006) CY - Hamburg, Germany DA - 2006-10-04 PY - 2006 AN - OPUS4-15836 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Hentschel, Manfred P. ED - Green, R. E. ED - Djordjevic, B. B. ED - Hentschel, M. P. T1 - Synchrotron Radiation Refraction Topography PY - 2003 SN - 3-540-40154-7 SP - 167 EP - 176 PB - Springer CY - Berlin AN - OPUS4-2765 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lange, Axel A1 - Kupsch, Andreas A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. T1 - DIRECTT-Rekonstruktionen im Vergleich zur gefilterten Rückprojektion N2 - Anhand von computertomografischen Messungen und Modellrechnungen werden DIRECTT-Rekonstruktionen im Vergleich mit gefilterten Rückprojektionen bewertet. Dazu wird die Rekonstruktionsqualität mittels einer zirkular erweiterten Modulations-Transfer-Funktion (MTF) und mit integralen Kenngrößen im Radon- und im Ortsraum verglichen. Zur Überprüfung der Rekonstruktionsgenauigkeit experimenteller Daten werden Mustermessungen einfacher Probengeometrien unter definierten physikalischen Bedingungen durchgeführt. Diese beinhalten die Monochromasie, die Unterdrückung von Kantenartefakten und die radiometrische Intensitätsbestimmung. Für die Qualität der Rekonstruktionen mittels DIRECTT erweisen sich sowohl unterschiedliche Rekonstruktionsfilter als auch der Verzicht auf jede Filterung als unerheblich, im Gegensatz zur gefilterten Rückprojektion. KW - Computertomografie KW - Gefilterte Rückprojektion KW - Rekonstruktionsalgorithmen KW - Iterative Rekonstruktion KW - DIRECTT KW - Konvergenz KW - Modulations-Transfer-Funktion (MTF) PY - 2014 UR - http://www.hanser-elibrary.com/doi/pdf/10.3139/120.110610 SN - 0025-5300 VL - 56 IS - 9 SP - 709 EP - 715 PB - Hanser CY - München AN - OPUS4-31378 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Bernd R. A1 - Hentschel, Manfred P. A1 - Lange, Axel T1 - SYRTOPO - Materialcharakterisierung an der BAMline N2 - Einleitung Die Bundesanstalt für Materialforschung und -prüfung (BAM) hat im Synchrotronstrahlungslabor BESSY (im Wissenschafts- und Technologiezentrum Berlin-Adlershof) ein Röntgen-Strahlrohr (BAMline) sowie einen Messplatz für die zerstörungsfreie Materialcharakterisierung aufgebaut. Der Messplatz erlaubt die Untersuchung mit monochromatischer Röntgenstrahlung im Energiebereich von 5keV bis 60keV mit hohem Photonenfluß. Seit Anfang 2001 läuft der Probebetrieb zur Optimierung der Strahlungsquelle sowie des experimentellen Aufbaus. Die Besonderheiten der BAMline im Vergleich zu Laboröntgenquellen sind der hohe Photonenfluss bei freier Wahl der Photonenenergie sowie die Polarisationseigenschaften und die außerordentliche Parallelität der Strahlung bei großem Strahlungsquerschnitt. Dies ermöglicht Refraktionstopogramme für Metall-Matrix-Komposite (MMC) in relativ kurzer Zeit, mit einer lateralen Ortsauflösung von 10µm, zu messen. Das neuartige ZfP-Verfahren der Röntgen-Refraktions-Topograhy wurde an anderer Stelle ausführlich beschrieben [1,2]. Es nutzt die Messtechnik der traditionellen Kleinwinkelstreuung auf unkonventionelle Weise, und wurde in den letzten zehn Jahren in unserem Labor entwickelte und an die fortgeschrittenen Anforderungen für die zerstörungsfreie Charakterisierung von neuartigen Werkstoffen wie faserverstärkten Kompositen und Keramiken angepasst. Das Verfahren basiert auf dem Brechungseffekt von Röntgenstrahlen. Auf Grund der kurzen Wellenlänge der Röntgenstrahlen (l » 0.1nm) können innere Oberflächen sowie Grenzflächenkonzentrationen von Nanometer Große detektiert werden, so dass mit Hilfe dieser Technik sehr leicht Partikel, Risse und Porengrößen im Sub-Mikrometer-Bereich gemessen werden können, ohne dabei die Proben zu zerstören, wie es bei mikroskopischen Techniken notwendig ist. Anwendungsfelder dieser Untersuchungsmethode sind z.B. die Erkennung von Faser-Matrix-Enthaftung nach Schlageinwirkung sowie Rissbildung durch Alterung und Herstellung bei faserverstärkten Kompositen. T2 - Jahrestagung Zerstörungsfreie Materialprüfung 2002 CY - Weimar, Deutschland DA - 2002-05-06 PY - 2002 UR - http://www.ndt.net/article/dgzfp02/papers/v16/v16.htm SN - 3-931381-39-0 N1 - Serientitel: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. – Series title: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. IS - 80-CD SP - 1(?) EP - 6(?) PB - DGZfP CY - Berlin AN - OPUS4-2793 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schors, Jörg A1 - Hentschel, Manfred P. A1 - Harbich, Karl-Wolfram A1 - Lange, Axel A1 - Müller, Bernd R. T1 - Röntgen-Topographie mit Klein- und Weitwinkel-Streuung und Röntgenrefraktions-Computertomographie KW - Röntgen-Streuung KW - Materialcharakterisierung KW - Komposite KW - Keramik KW - Risse KW - Computertomographie PY - 2003 SN - 0948-5112 IS - 86 SP - 11 Seiten PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung CY - Berlin AN - OPUS4-2652 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Müller, Bernd R. T1 - Refraktions-Interface-Radiographie N2 - Nanoskalige Strukturen und Grenzflächen bestimmen zunehmend die Funktionalität moderner Materialien und Bauteile und erfordern ihre zerstörungsfreie Charakterisierung mit angepasster Ortsauflösung. Dazu sind wegen der passenden Wellenlängen Röntgen-Refraktionsverfahren einsetzbar. Die resultierende Kleinwinkelstreuung verursacht lokal große Intensitäten, die durch Umlagerung oder Fokussierungseffekte das Primärstahlniveau übersteigen können. Mit monochromatischer Synchrotronstrahlung an homogenen Musterproben einfacher Geometrien (Platten und Zylinder) wird die Dominanz der Refraktionsintensität gegenüber der Totalreflexion dargestellt. Der Refraktionseffekt kann für Einstrahlwinkel bis zu einigen Grad genutzt werden; die typischen Streuwinkel liegen in der Größenordnung von Bogensekunden bis -minuten. Darüber hinaus wird die Bestimmung der inneren Oberflächen, Poren und Nanorisse auch orientierungsspezifisch mit Laborausrüstungen demonstriert. T2 - DGZfP-Jahrestagung 2013 CY - Dresden, Germany DA - 06.05.2013 KW - Röntgenrefraktion KW - Kleinwinkelstreuung KW - Refraktionstopographie KW - Nanostrukturen PY - 2013 SN - 978-3-940283-49-8 IS - Mo.2.A.2 SP - 1 EP - 10 AN - OPUS4-28691 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rack, A. A1 - Zabler, S. A1 - Müller, Bernd R. A1 - Riesemeier, Heinrich A1 - Weidemann, Gerd A1 - Lange, Axel A1 - Goebbels, Jürgen A1 - Hentschel, Manfred P. A1 - Görner, Wolf T1 - High resolution synchrotron-based radiography and tomography using hard X-rays at the BAMline (BESSY II) N2 - The use of high brilliance and partial coherent synchrotron light for radiography and computed tomography (CT) allows to image micro-structured, multi-component specimens with different contrast modes and resolutions up to submicrometer range. This is of high interest for materials research, life science and non-destructive evaluation applications. An imaging setup for microtomography and radiography installed at BESSY II (a third generation synchrotron light source located in Berlin, Germany) as part of its first hard X-ray beamline (BAMline) can now be used for absorption, refraction as well as phase contrast — dedicated to inhouse research and applications by external users. Monochromatic synchrotron light between 6 keV and 80 keV is attained via a fully automated double multilayer monochromator. For imaging applications the synchrotron beam transmitted by the sample is converted with a scintillator into visible light. By use of microscope optics this luminescence image is then projected onto, e.g., a CCD chip. Several scintillating materials are used in order to optimise the performance of the detector system. Different optical systems are available for imaging ranging from a larger field of view and moderate resolutions (macroscope — up to 14 mm x 14 mm field of view) to high resolution (microscope — down to 0.35 μm pixel size), offering magnifications from 1.8× to 40×. Additionally asymmetric cut Bragg crystals in front of the scintillator can be used for a further magnification in one dimension by a factor of about 20. Slow and fast cameras are available, with up to 16 bit dynamic range. We show the suitability of the setup for numerous applications from materials research and life science. KW - Microtomography KW - Non-destructive evaluation KW - Synchrotron instrumentation KW - Coherent imaging KW - X-ray refraction KW - Phase contrast KW - Holotomography KW - Synchrotron-CT KW - Scintillator KW - Bragg magnification PY - 2008 DO - https://doi.org/10.1016/j.nima.2007.11.020 SN - 0168-9002 SN - 0167-5087 VL - 586 IS - 2 SP - 327 EP - 344 PB - North-Holland CY - Amsterdam AN - OPUS4-17738 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Manke, I. A1 - Kardjilov, N. A1 - Arlt, Tobias A1 - Grothausmann, R. T1 - Rekonstruktion limitierter CT-Messdatensätze von Brennstoffzellen mit Directt N2 - Die Aufklärung spezifischer Fragestellungen zur Funktionalität von PEM(polymer electrolyte membrane)- und DMFC(Direct Methanol)-Brennstoffzellen bedarf der 3D-Abbildung der spezifischen Komponenten mit unterschiedlichen Strahlungsarten: des Wassergehalts in den Flow Fields mit Neutronen, der Katalysator-Alterung in der MEA (membrane electrode assembly) mit Synchrotronstrahlung und der freien (reaktiven) Katalysator-Oberfläche von Nano-Partikeln mit TEM-Elektronen-Tomografie. Diese Messungen im Bereich der mm- bis nm-Skala unterliegen dabei erheblichen Restriktionen: einer ortsabhängigen Verschmierung der Neutronenradiogramme, Manipulatorinstabilitäten der Synchrotronmessungen sowie einer Kombination von Limited-View-Datensätzen, wenigen Projektionswinkeln und teilweiser Nichtdurchstrahlbarkeit in der Elektronen-CT. Die Vorteile eines fortentwickelten Directt-Algorithmus für die Bewältigung dieser Randbedingungen gegenüber gefilterten Rückprojektionen werden aufgezeigt. KW - Computed tomography KW - Reconstruction algorithm KW - Electron tomography KW - Neutron tomography KW - Catalyst KW - Fuel cell PY - 2010 SN - 0025-5300 VL - 52 IS - 10 SP - 676 EP - 683 PB - Hanser CY - München AN - OPUS4-22070 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Hamm, B. A1 - Rogalla, P. A1 - Diederichs, G. A1 - Issever, A.S. T1 - First Synchrotron Refraction CT of Cartilage KW - X-ray Refraction KW - Computed Tomography KW - DEI KW - Cartilage PY - 2008 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annual_report_2007-v2.pdf#page=292 SN - 0179-4159 SP - 292 EP - 296 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-17661 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Kupsch, Andreas T1 - A comfortable procedure for correcting X-ray detector backlight N2 - A novel approach is suggested to strongly suppress artifacts in radiography and computed tomography caused by the effect of diffuse background signals 'backlighting' of 2D X-ray detectors. Depending on the detector geometry the mechanism may be different. Either based on the optical scattering of the fluorescent screen materials into the optical detection devices or Compton or X-ray fluorescence scattering by the detector components. Consequently, these erroneous intensity portions result in locally different violations of Lambert Beer's law in single projections (radiographs) as a function of the detector area coverage and the magnitude of the attenuation. The absorption of multiple metal sheets is investigated by monochromatic synchrotron radiation, thus excluding beam hardening. The proposed correction procedure simply requires the individual subtraction of one and the same fraction of the primary and transmitted mean intensity, as a constant (non-local) scattering mechanism is assumed. KW - X-ray detector backlighting KW - Radiography KW - Fluorescent screen KW - Diffuse background KW - Computed tomography PY - 2013 DO - https://doi.org/10.1088/1742-6596/425/19/192015 SN - 1742-6588 SN - 1742-6596 VL - 425 IS - 19 SP - 192015-1 EP - 192015-4 PB - IOP Publ. CY - Bristol, UK AN - OPUS4-28262 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Wald, Oliver T1 - Quantitative X-ray Determination of CFRP Micro Structures T2 - International Symposium on NDT in Aerospace CY - Fürth, Germany DA - 2008-12-03 KW - Neutronen-Radiographie KW - Neutronen-Tomographie KW - Tomographische Rekonstruktionsalgorithmen KW - Brennstoffzellen KW - In-Situ Radiologie PY - 2008 SN - 978-3-940283-12-2 N1 - Serientitel: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. – Series title: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. IS - DGZfP-BB 114 (X-Ray/Lecture 13) SP - 89 EP - 98 PB - DGZfP CY - Berlin AN - OPUS4-18606 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Görner, Wolf A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. A1 - Riesemeier, Heinrich A1 - Krumrey, M. A1 - Ulm, G. T1 - The first hard X-rays at the BAMline PY - 2001 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2000.pdf#page=329 SN - 0179-4159 SP - 329 EP - 331 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-1299 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hentschel, Manfred P. A1 - Lange, Axel A1 - Müller, Bernd R. A1 - Schors, Jörg A1 - Harbich, Karl-Wolfram T1 - Röntgen-Refraktions-Computer-Tomographie N2 - Für die Charakterisierung Neuer Werkstoffe, vornehmlich Nichtmetalle, hat sich das Verfahren der Röntgen-Refraktions-Topographie bewährt. Es handelt sich phänomenologisch um eine Technik der Röntgen-Kleinwinkel-Streuung mit Probekörper-Abtastung bei fest vorgewähltem Streuwinkel. Gegenüber der klassischen Beugungstheorie dominieren jedoch bei der Streuung an Strukturen oberhalb von 0.3 µm Größe röntgenoptische Brechungseffekte. Detektierbar sind damit innere Ober- und Grenzflächen, insbesondere Mikrorisse unterhalb der lichtmikroskopischen Erkennbarkeit. Da es sich hierbei um eine Durchstrahlungs-Technik handelt, überlagern jedoch die Strukturen zu einer Projektion, analog zu den radiographischen Verfahren. Um auch Informationen entlang der Durchstrahlungs-Richtung in der Tiefe des Probekörpers zu erhalten, wird unter kleinen Streuwinkeln die Computer-Tomographie durchgeführt, im ersten Ansatz mit nur zwei Meßkanälen, jeweils für die Messung der Absorptions- und der Refraktions-Intensität. Dazu werden nacheinander 360 Linear-Scans nach Drehung von jeweils 1° aufgenommen. Die Intensitätswerte werden nach den Regeln der fouriergefilterten Rückprojektion zu Computer-Tomogrammen verarbeitet. Die Ergebnisse visualisieren die Anordnung von Grenzflächen und innere Oberflächen, die sich für zahlreiche nichtmetallische Werkstoffe, vor alllem im Transportmittel-Leichtbau als relevante Mikrostrukturen für das Versagens-Verhalten und die Werkstoff-Optimierung eignen. Zum Vergleich entstehen aus den simultanen Absorptionsmessungen gleichzeitig die klassischen Computer-Tomogramme, die ausschließlich Dichteänderungen anzeigen. T2 - Jahrestagung Zerstörungsfreie Materialprüfung 1999 CY - Celle, Deutschland DA - 1999-05-10 KW - Röntgentomographie KW - Röntgen-Refraktions-Computer-Tomographie PY - 1999 UR - http://www.ndt.net/abstract/dgzfp99/data/40.htm SN - 3-931381-27-7 VL - 1 IS - 68 SP - 361 EP - 369 PB - DGZfP CY - Berlin AN - OPUS4-715 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Marco A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Goebbels, Jürgen T1 - Synchrotron Refraction CT and Synchrotron Bragg Magnification CT for NDE T2 - International Symposium on Digital industrial Radiology and Computed Tomography (DIR 2007) CY - Lyon, France DA - 2007-06-25 KW - X-ray Refraction KW - Diffraction Enhanced Imaging (DEI) KW - Bragg Magnification KW - Synchrotron Radiation KW - Computed Tomography (CT) KW - Metal Matrix Composites (MMC) KW - Lightweight Materials KW - Aerospace PY - 2007 IS - CD-ROM SP - 1 EP - 8 CY - Lyon, France AN - OPUS4-16366 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. A1 - Harwardt, Michael A1 - Lange, Axel T1 - Synchrotron-Refraktions-Computer Tomographie für die Materialforschung T2 - DGZfP Jahrestagung CY - Rostock, Deutschland DA - 2005-05-02 KW - Computer-Tomographie KW - Synchrotronstrahlung KW - Refraktionskontrast KW - Bragg-Vergrößerung PY - 2005 SN - 3-931381-64-1 N1 - Serientitel: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. – Series title: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. IS - 94-CD SP - 1(?) EP - 7(?) PB - DGZfP CY - Berlin AN - OPUS4-11698 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Müller, Bernd R. A1 - Hentschel, Manfred P. ED - Czichos, Horst T1 - Micro-diagnostics: X-ray and synchrotron techniques N2 - Beyond classical X-ray techniques are used for the purpose of preferably short-term applications, but some supplementary X-ray and synchrotron techniques for higher resolution microdiagnostics take advantage of scattering effects. In contrast to directly imaging methods their resolution is only limited by the diffraction limit of the X-ray wavelength, far below the atomic dimensions. These techniques of scanning topography and refraction synchrotron tomography may permit the systematic diagnostics for finding and exploiting structure/property relations like correlations among atomic, nano and microstructures with macroscopic properties. Their basic advantage over microscopic techniques is their potential for the non-destructive characterisation of materials, far from invasive sample treatments. They combine scattering and spatial resolution. KW - X-ray KW - X-ray refraction KW - X-ray refraction topography KW - X-ray refraction tomography KW - X-ray scattering KW - USAXS KW - Wide angle X-ray scattering KW - WAXS KW - Interfaces KW - Inner surface density KW - Diffraction enhanced imaging KW - DEI KW - Synchrotron radiation KW - Synchrotron refraction computed tomography KW - SRCT KW - Fibre orientation KW - X-ray diffraction microscopy PY - 2013 SN - 978-3-642-25849-7 SN - 978-3-642-25850-3 DO - https://doi.org/10.1007/978-3-642-25850-3_14 IS - Chapter 14 SP - 287 EP - 300 PB - Springer CY - Berlin Heidelberg AN - OPUS4-27746 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Fensch-Kleemann, Elisabeth A1 - Müller, Bernd R. A1 - Harbich, Karl-Wolfram A1 - Hentschel, Manfred P. ED - Kriegesmann, J. T1 - Gefügeanalyse keramischer Werkstoffe mittels Röntgen-Refraktion PY - 2002 SN - 3-87156-091-X IS - Kap. 6.1.4.1 SP - 1 EP - 24 PB - Deutscher Wirtschaftsdienst CY - Köln AN - OPUS4-2066 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hentschel, Manfred P. A1 - Harbich, Karl-Wolfram A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Schors, Jörg A1 - Wald, Oliver ED - Gerhard Busse, ED - Danny Van Hemelrijck, ED - Igor Solodov, ED - Anastasopoulos, Athanasios T1 - NDE of micro structured materials by X-ray diffraction and refraction topography T2 - 4th International Conference of Emerging Technologies in Non-Destructive Testing (ETNDT 4) CY - Stuttgart, Germany DA - 2007-04-02 KW - Nondestructive testing KW - X-ray scattering KW - X-ray topography KW - Computed topography KW - Synchrotron refraction computed tomography KW - Structure property relations KW - Composite damaging KW - Ceramics KW - Foams PY - 2007 SN - 978-0-415-46476-5 SP - 15 EP - 22 PB - Taylor & Francis CY - London, UK AN - OPUS4-17561 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Hentschel, Manfred P. A1 - Bruno, Giovanni A1 - Onel, Yener A1 - Wolk, Thomas A1 - Staude, Andreas A1 - Ehrig, Karsten A1 - Müller, Bernd R. T1 - Evaluating porosity in cordierite diesel particulate filter materials: advanced X-ray techniques and new statistical analysis methods T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 2014-10-06 KW - Porous ceramics KW - Diesel particulate filters KW - Pore orientation KW - X-ray computed tomography KW - X-ray refraction KW - DIVA algorithm KW - Phase contrast KW - Edge artefact KW - Soft matter radiography KW - Wavelet transform KW - Huygens elementary waves PY - 2014 SN - 978-80-214-5018-9 SP - 1 EP - 8(?) AN - OPUS4-31973 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bruno, Giovanni A1 - Ehrig, Karsten A1 - Haarring, Holger A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Illerhaus, Bernhard A1 - Kupsch, Andreas A1 - Lange, Axel A1 - Meinel, Dietmar A1 - Müller, Bernd R. A1 - Onel, Yener A1 - Staude, Andreas A1 - Wolk, Thomas T1 - Industrial and synchrotron X-ray CT applications for materials characterisation N2 - The combination of tomographic, microstructural data with other experimental techniques and with modeling is paramount, if we want to extract the maximum amount of information on material and component properties. In particular, quantitative image analysis, statistical approaches, direct discretization of tomographic reconstructions represent concrete possibilities to extend the power of the tomographic 3D representation to insights into the material and component performance. This logic thread holds equally for industrial and academic research, and valorizes expensive experiments such as those carried out at synchrotron sources, which cannot be daily repeated. We shall show a few examples of possible use of X-ray tomographic data for quantitative assessment of damage evolution and microstructural properties, as well as for non-destructive testing. We will also show how X-ray refraction computed tomography (CT) can be highly complementary to classic absorption CT, being sensitive to internal interfaces. T2 - iCT Conference 2014 - Conference on industrial computed tomography CY - Wels, Austria DA - 25.02.2014 KW - X-ray absorption and refraction CT KW - Quantitative image analysis KW - Statistical analysis KW - Complex microstructure PY - 2014 SN - 978-3-8440-2557-6 SP - 15 EP - 31 PB - Shaker CY - Aachen AN - OPUS4-30484 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -