TY - CONF A1 - Sturm, Heinz T1 - Technology transfer of a new developed exploratory Scanning Force Microscope, fine-tuned to meet the demands of the upcoming Nanobiotechnology industries T2 - International Forum On Project Development, Industrial Heritage Program CY - Bologna, Italy DA - 2005-02-28 PY - 2005 AN - OPUS4-6976 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Sturm, Heinz T1 - Messung elektrischer Eigenschaften in der Rasterkraftmikroskopie: Leitfähigkeitskontrast auf Kohlefaseroberflächen T2 - Tagung "Raster-Sonden-Mikorskopien und organische Materialien IV" CY - Munich, Germany DA - 1995-10-11 PY - 1995 AN - OPUS4-6388 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Sturm, Heinz T1 - Analysis of Scanning Probe Microscopy (SPM) Piezos T2 - Digital-Instruments User-Workshop an der TU Dresden CY - Dresden, Germany DA - 1999-04-07 PY - 1999 AN - OPUS4-6498 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Braun, Ulrike A1 - Lorenz, Edelgard A1 - Weimann, Christiane A1 - Sturm, Heinz A1 - Karimov, I. A1 - Ettl, J. A1 - Meier, R. A1 - Wohlgemuth, W. A. A1 - Berger, H. A1 - Wildgruber, M. T1 - Mechanic and surface properties of central-venous port catheters after removal: A comparison of polyurethane and Silicon rubber materials N2 - Central venous port devices made of two different polymeric materials, thermoplastic polyurethane (TPU)and silicone rubber (SiR), were compared due their material properties. Both naïve catheters as well as catheters after removal from patients were investigated. In lab experiments the influence of various chemo-therapeutic solutions on material properties was investigated, where as the samples after removal were compared according to the implanted time inpatient. The macroscopic,mechanical performance was assessed with dynamic, specially adapted tests for elasticity. The degradation status of the materials was determined with common tools of polymer characterisation, such as infrared spectroscopy, molecular weight measurements and various methods of thermal analysis. The surface morphology was an alysed using scanning electron microscopy. A correlation between material properties and clinical performance was proposed. The surface morphology and chemical composition of the polyurethane catheter materials can potentially result in increased susceptibility of the catheter to bloodstream infections and thrombotic complications. The higher mechanic failure,especially with increasing implantation time of the silicone catheters is related to the lower mechanical performance compared to the polyurethane material as well as loss of barium sulphate filler particles near the surface of the catheter. This results in preformed microscopic notches, which act as predetermined sites of fracture. KW - Thermoplastic polyurethane (TPU) KW - Silicone rubber (SiR) KW - Catheters KW - Central venous access port KW - Complication KW - Structure propertyrelationship KW - Mechanical testing PY - 2016 DO - https://doi.org/10.1016/j.jmbbm.2016.08.002 SN - 1751-6161 SN - 1878-0180 VL - 64 SP - 281 EP - 291 PB - Elsevier Ltd. AN - OPUS4-37178 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Munz, Martin A1 - Sturm, Heinz A1 - Schulz, Eckhard A1 - Hinrichsen, G. T1 - The scanning force microscope as a tool for the detection of local mechanical properties within the interphase of fibre reinforced polymers N2 - Scanning force microscopy (SFM) has been used to assess the local mechanical properties of fibre-reinforced polymers. Using a sinusoidal displacement modulation (DM) and lock-in technique the method allows to characterize local viscoelastic properties with a high lateral resolution. The simultaneous measurement of the local electrical conductivity is proposed which facilitates the interpretation of the mechanical data. The investigation of cross-sections perpendicular to the axis of carbon fibres embedded in PPS delivers some information about the change in local stiffness within the interfacial region. As a first approach, assuming a single-exponential decrease in local stiffness along a radial line from fibre to polymer we find characteristic decay lengths which are distributed in a range between 20 and 80nm. Further, a modified DM-mode is proposed which is expected to provide a contrast enhancement of the signal which is related to local stiffness. This can be achieved by installing an additional feedback loop which keeps constant the amplitude of dynamic indentation (CDI-mode). KW - Polymer-matrix composites (PMC´s) KW - Interface/interphase KW - SFM/AFM KW - Surface properties KW - Nondestructive testing PY - 1998 DO - https://doi.org/10.1016/S1359-835X(98)00077-3 SN - 1359-835X VL - 29 SP - 1251 EP - 1259 PB - Elsevier CY - Oxford AN - OPUS4-1294 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Sturm, Heinz A1 - Geuss, Markus A1 - Schulz, Eckhard ED - Konsta, A. T1 - Scanning force microscopy investigations on electroactive polymer films N2 - The authors present investigations on a PVDF (polyvinylidenefluoride) film supplied with top and bottom Au electrodes, which is analysed using a SFM and a contactless optical sensor to measure the sample strain with respect to applied fields. T2 - 10th IEEE International Symposium on Electrets (ISE) CY - Delphi, Greece DA - 1999-09-22 PY - 1999 SN - 0-7803-5025-1 DO - https://doi.org/10.1109/ISE.1999.832086 SP - 465 EP - 468 PB - IEEE Operations Center CY - Piscataway, NJ AN - OPUS4-6862 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Sturm, Heinz T1 - AFM cantilevers as mechanical sensors T2 - Nano-Seminar am NanoSYD-Institut der süddänischen Universität in Sonderborg CY - Sonderborg, Denmark DA - 2008-12-02 PY - 2008 AN - OPUS4-18266 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Solomun, Tihomir A1 - Schimanski, A. A1 - Sturm, Heinz A1 - Illenberger, E. T1 - Reactions of amide group with fluorine as revealed with surface analytics N2 - Thin polyamide-6 films were exposed to fluorine gas and analysed with photoelectron and infrared spectroscopies. Fluorine cleaves the amide C–N bond resulting in the formation of the –COOH and –NF2 terminal groups. This is evident from large shifts in the N1s binding energy (+5 eV) and C=O stretching frequency (~80 cm-1), appearance of ester oxygen in the XPS spectra, as well as by the 19F nmr spectra of volatile products consistent with a terminal NF2 group. KW - Gasfluorierung KW - Polyamid-6 KW - XPS KW - IR KW - -COOH und NF2-Gruppen PY - 2004 UR - http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%235231%232004%23996109995%23499295%23FLA%23&_cdi=5231&_pubType=J&_auth=y&_acct=C000049503&_version=1&_urlVersion=0&_userid=963821&md5=baea8e0df63660c666921ef377c00e40 SN - 0009-2614 SN - 1873-4448 VL - 378 SP - 312 EP - 316 PB - North-Holland Publ. Co. CY - Amsterdam AN - OPUS4-3439 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Solomun, Tihomir A1 - Seitz, H. A1 - Sturm, Heinz T1 - DNA damage by low-energy electron impact: dependence on guanine content KW - DNA oligonucleotide KW - Low energy electrons KW - Secondary electrons KW - Damage KW - Guanine content PY - 2009 DO - https://doi.org/10.1021/jp905263x SN - 1520-6106 SN - 1089-5647 VL - 113 IS - 34 SP - 11557 EP - 11559 PB - Soc. CY - Washington, DC AN - OPUS4-20704 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Sturm, Heinz T1 - Nichtlinearität und Hysterese von AFM-Piezos T2 - 24th Intern. TopoMetrix-Workshop: Aktuelle Entwicklungen in der Nanotechnologie und Rastersondenmikroskopie, Humboldt-Universität CY - Berlin, Germany DA - 1998-03-12 PY - 1998 AN - OPUS4-6462 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Sturm, Heinz T1 - Lithography on Polymers using a Scanning Force Microscope (SFM) and a Environmental Scanning Electron Microscope (ESEM) T2 - Seminar International PhD Program CY - Berlin, Germany DA - 2004-04-30 PY - 2004 AN - OPUS4-3504 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Sturm, Heinz T1 - Rastersondenverfahren T2 - BAM, DGM Fachausschuss "Gefüge und Eigenschaften von Polymerwerkstoffen" CY - Berlin, Germany DA - 2003-12-05 PY - 2003 AN - OPUS4-4099 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Sturm, Heinz T1 - Dynamics of phase transitions in polymer thin films upon single femtosecond laser pulse irradiation T2 - Second International Conference on Photo-Induced Phase Transitions Cooperative, non-linear and functional properties CY - Rennes, France DA - 2005-05-24 PY - 2005 AN - OPUS4-7430 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -