TY - CONF A1 - Matschat, Ralf A1 - Kipphardt, Heinrich A1 - Czerwensky, Michael A1 - Richter, Silke A1 - Heinrich, Hans-Joachim ED - Abiko, K. ED - Takaki, S. T1 - The System of Primary Pure Metals Established at BAM - Recent Developments T2 - 9th international conference on ultrahigh-purity base metals CY - Sendai, Japan DA - 2002-10-14 PY - 2002 SP - 119 CY - Sendai AN - OPUS4-1601 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zhou, T. A1 - Richter, Silke A1 - Matschat, Ralf A1 - Kipphardt, Heinrich T1 - Determination of the total purity of a high-purity silver material to be used as a primary standard for element determination N2 - A candidate material for the use as primary standard for silver determination was characterized with respect to total purity. Except the radioactive elements and He, all possible impurities were considered. Based on glow discharge mass spectrometry, inductively coupled plasma-mass spectrometry and carrier gas hot extraction measurements, the demonstrated total purity and its standard uncertainty is w(Ag) = (99.999 52 ± 0.000 11) %. The purity value and its uncertainty is dominated by the contributions from the measurements of the nonmetallic impurities, namely S, N, C and O. KW - Silver KW - Purity KW - Total purity KW - Primary standard KW - Element determination PY - 2013 U6 - https://doi.org/10.1007/s00769-013-0988-5 SN - 0949-1775 SN - 1432-0517 VL - 18 IS - 4 SP - 341 EP - 349 PB - Springer CY - Berlin AN - OPUS4-28971 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Richter, Silke A1 - Sargent, M. A1 - Schiel, D. A1 - Kipphardt, Heinrich T1 - Known purity - the fundament of element determination by atomic spectrometry N2 - Millions of measurements are performed each year by liquid based analytical atomic spectrometry to support healthcare, diagnostic tests, environmental monitoring, material assay, product development and safety. Despite the effort to develop absolute methods, most methods still depend on calibration solutions, which are gravimetric mixtures of high purity solvents and high purity (source material) metals or compounds. As in the real world ideal purity does not exist, the impurity of the solvent and the purity of the source material needs to be known. The impurity of a solvent with respect to one analyte can be measured rather easily and with low limits of determination. In contrast the measurement of the purity of the source material, i.e., the mass fraction of the main constituent in a high purity metal, is more difficult to determine. It becomes even more difficult when the source material is not a pure metal but a compound since problems regarding stoichiometry arise additionally. Although the major producers of calibration solutions make a special effort to determine the purity of the source material, the actual purity statement is often incomplete or not demonstrated. The main reason for this situation is the complexity and high effort necessary to fully characterize such a material. This problem holds to a very wide extent also for the primary standards for element determination at the National Metrology Institutes and Designated Institutes (NMIs and DIs). It is the task of the NMIs and DIs to realise and disseminate primary standards for providing traceability to the International System of Units (SI). The primary elemental standards at the NMIs should provide the link to secondary standards produced by commercial producers and other independently prepared standards for element determination. Without such primary standards, elemental calibration solutions may vary and, depending on the uncertainty required, comparability of measurement in time and space results cannot be achieved. KW - Traceability KW - Metrology KW - Atomic spectrometry KW - Primary reference materials PY - 2013 U6 - https://doi.org/10.1039/c3ja90045b SN - 0267-9477 SN - 1364-5544 VL - 28 IS - 10 SP - 1540 EP - 1543 PB - Royal Society of Chemistry CY - London AN - OPUS4-30301 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - D'Agostino, G. A1 - Bergamaschi, L. A1 - Giordani, L. A1 - Oddone, M. A1 - Kipphardt, Heinrich A1 - Richter, Silke T1 - Use of instrumental neutron activation analysis to investigate the distribution of trace elements among subsamples of solid materials N2 - The results of analytical measurements performed with solid-sampling techniques are affected by the distribution of the analytes within the matrix. The effect becomes significant in case of determination of trace elements in small subsamples. In this framework we propose a measurement model based on Instrumental Neutron Activation Analysis to determine the relative variability of the amount of an analyte among subsamples of a material. The measurement uncertainty is evaluated and includes the counting statistics, the full-energy gamma peak efficiency and the spatial gradient of the neutron flux at the irradiation position. The data we obtained in a neutron activation experiment and showing the relative variability of As, Au, Ir, Sb and W among subsamples of a highly pure Rh foil are also presented. KW - Instrumental neutron activation analysis KW - Homogeneity KW - Rhodium KW - Uncertainty PY - 2014 SN - 0026-1394 SN - 1681-7575 VL - 51 SP - 1 EP - 6 PB - Inst. of Physics Publ. CY - Bristol AN - OPUS4-30302 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Plotnikov, Alexei A1 - Pfeifer, Jens A1 - Richter, Silke A1 - Kipphardt, Heinrich A1 - Hoffmann, V. T1 - Determination of major nonmetallic impurities in magnesium by glow discharge mass spectrometry with a fast flow source using sintered and pressed powder samples N2 - Fast flow glow discharge mass spectrometry with a Grimm-type ion source providing a high sputter rate was used for the determination of major nonmetallic impurities in magnesium. The analytical signal was found to be strongly influenced by the electrical discharge parameters. For calibration by standard addition, synthetic standard samples were produced in two different ways—namely, by pressing and by sintering doped metal powders. The observed sensitivity of the calibration curves was shown to depend on the particle size of the powder. For the magnesium powders, the mass fractions of oxygen, nitrogen, boron, and silicon were determined to be about 0.01 kg·kg-1 (relative standard deviation approximately 10–20 %), 2,700 mg·kg-1, 150 mg·kg-1, and 300 mg·kg-1, respectively. KW - Glow discharge mass spectrometry KW - Magnesium matrix KW - Nonmetallic impurities KW - Fast flow source KW - Electrical parameters KW - Calibration samples KW - Non-metals KW - Standard samples KW - Powders PY - 2014 U6 - https://doi.org/10.1007/s00216-014-8185-x SN - 1618-2642 SN - 1618-2650 VL - 406 IS - 29 SP - 7463 EP - 7471 PB - Springer CY - Berlin AN - OPUS4-31975 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kaltenbach, A. A1 - Nordmann, J. A1 - Görlitz, V. A1 - Pape, C. A1 - Richter, Silke A1 - Kipphardt, Heinrich A1 - Kopp, G. A1 - Jährling, R. A1 - Rienitz, O. A1 - Güttler, B. T1 - Gravimetric preparation and characterization of primary reference solutions of molybdenum and rhodium N2 - Gravimetrically prepared mono-elemental reference solutions having a well-known mass fraction of approximately 1 g/kg (or a mass concentration of 1 g/L) define the very basis of virtually all measurements in inorganic analysis. Serving as the starting materials of all standard/calibration solutions, they link virtually all measurements of inorganic analytes (regardless of the method applied) to the purity of the solid materials (high-purity metals or salts) they were prepared from. In case these solid materials are characterized comprehensively with respect to their purity, this link also establishes direct metrological traceability to The International System of Units (SI). This, in turn, ensures the comparability of all results on the highest level achievable. Several national metrology institutes (NMIs) and designated institutes (DIs) have been working for nearly two decades in close cooperation with commercial producers on making an increasing number of traceable reference solutions available. Besides the comprehensive characterization of the solid starting materials, dissolving them both loss-free and completely under strict gravimetric control is a challenging problem in the case of several elements like molybdenum and rhodium. Within the framework of the European Metrology Research Programme (EMRP), in the Joint Research Project (JRP) called SIB09 Primary standards for challenging elements, reference solutions of molybdenum and rhodium were prepared directly from the respective metals with a relative expanded uncertainty associated with the mass fraction of Urel(w)<0.05 %. To achieve this, a microwave-assisted digestion procedure for Rh and a hotplate digestion procedure for Mo were developed along with highly accurate and precise inductively coupled plasma optical emission spectrometry (ICP OES) and multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) methods required to assist with the preparation and as dissemination tools. KW - Digestion KW - Rhodium KW - Molybdenum KW - Reference solution KW - Metrological traceability KW - ICP OES KW - MC-ICP-MS PY - 2015 U6 - https://doi.org/10.1007/s00216-014-8395-2 SN - 1618-2642 SN - 1618-2650 VL - 407 IS - 11 SP - 3093 EP - 3102 PB - Springer CY - Berlin AN - OPUS4-33065 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kramer, Claus A1 - Ried, Peter A1 - Mahn, Stefan A1 - Richter, Silke A1 - Langhammer, Nicole A1 - Kipphardt, Heinrich T1 - Design and application of a versatile gas calibration for non-metal determination by carrier gas hot extraction N2 - In carrier gas hot extraction the calibration of low amounts of non-metals with masses of a few micrograms with small uncertainty remains a challenge. To achieve high flexibility a high precision gas mixture pump was combined with an automated syringe drive. The gas mixing pump allows filling the syringe with different gas compositions; the automated syringe drive allows matching to modulate the signal profiles to those of real samples. The system was designed and its experimental potential explored. The resulting calibration curves were comparable to those obtained by calibration using solid materials of sufficient purity and stoichiometry. However smaller uncertainties and lower limits of quantification (i.e. 0.5 µg and 0.6 µg for O and N, respectively) were found using the gas calibration device. KW - Non-metal determination KW - CGHE KW - Gas calibration PY - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-336130 SN - 1759-9660 SN - 1759-9679 VL - 7 IS - 13 SP - 5468 EP - 5475 PB - RSC Publ. CY - Cambridge AN - OPUS4-33613 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Richter, Silke A1 - Roethke, A. A1 - Rienitz, O. A1 - Matschat, Ralf A1 - Schiel, D. A1 - Jaehrling, R. A1 - Goerlitz, V. A1 - Kipphardt, Heinrich T1 - SI-traceable monoelemental solutions on the highest level of accuracy: 25 years from the foundation of CCQM to recent advances in the development of measurement methods N2 - Within the Working Group on Inorganic Analysis (IAWG) of the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM) international key comparisons and pilot studies related to inorganic analysis are carried to ensure consistency in this field at the highest level. Some of these comparisons deal directly with the preparation and characterization of monoelemental solutions or with topics, closely related. The importance of monoelemental solutions lies in the fact that almost every measurement in inorganic analysis relies on the comparison with either a reference material, or references in form of solutions, usually (mono)elemental solutions. All quantitative measurement approaches, e.g. isotope dilution or standard addition, need an accurate reference solution made from a well characterized reference material, prepared under full gravimetric control. These primary (monoelemental) solutions do not only serve as arbitrary references/calibration solutions, but they also link up measurement results to the International System of units (SI), this way establishing the so-called metrological traceability to a measurement unit of the SI. Without such solutions on the highest possible level of accuracy and with the smallest possible associated uncertainties (for e.g. element content and/or impurities), an analysis itself can never be as good as it could be with appropriate reference solutions. This article highlights select key comparisons and pilot studies dealing with monoelemental solution related topics within the IAWG from the foundation of CCQM – 25 years ago – up to latest achievements in the field of inorganic analysis. KW - Metrology KW - SI Traceability KW - CCQM PY - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-496080 SN - 0026-1394 SN - 1681-7575 SP - 1 EP - 23 PB - IOP CY - Bristol AN - OPUS4-49608 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gonzales-Gago, C. A1 - Smid, P. A1 - Hofmann, T. A1 - Venzago, C. A1 - Hoffmann, V. A1 - Gruner, W. A1 - Pfeifer, Jens A1 - Richter, Silke A1 - Kipphardt, Heinrich T1 - Investigations of matrix independent calibration approaches in fast flow glow discharge mass spectrometry N2 - The performance of glow discharge mass spectrometry (GD-MS) is investigated for the accurate quantification of metallic impurities and oxygen in solid samples using the fast flow source GD-MS instrument ELEMENT GD. Different quantification approaches based on relative and absolute sensitivity factors are evaluated for the determination of metallic impurities using three sample matrixes (Al, Cu and Zn). The effect of the discharge conditions (voltage, current, discharge gas pressure/flow) on the sensitivity is investigated and the parameters are optimized to favour matrix independent calibrations. Improved standard relative sensitivity factors (StdRSFs) are calculated under optimal conditions based on multi-matrix calibrations. The sputtering rate corrected calibration is also presented as a multi-matrix calibration approach. The capabilities of GD-MS for oxygen determination are also investigated using a set of new conductive samples containing oxygen with mass fractions in the percent range in three different matrices (Al, Mg and Cu) produced by a sintering process. Poor limits of detection (in the order of g/kg) were obtained as consequence of the reduced sensitivity of oxygen in GD-MS and high oxygen background signal intensity as well as its variations. The absolute sensitivity procedure is shown as a matrix-independent approach, which provides quantitative values consistent with those obtained by carrier gas hot extraction (CGHE). KW - Fast flow GD KW - GDMS KW - Calibration KW - Matrix independent calibration PY - 2019 U6 - https://doi.org/10.1039/c9ja00023b SN - 1364-5544 SN - 0267-9477 VL - 34 IS - 6 SP - 1109 EP - 1125 PB - Royal Society of Chemistry CY - London AN - OPUS4-47842 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Matschat, Ralf A1 - Richter, Silke A1 - Vogl, Jochen A1 - Kipphardt, Heinrich T1 - On the way to SI traceable primary transfer standards for amount of substance measurements in inorganic chemical analysis N2 - During its 25 years of existence, the Inorganic Analysis Working Group of the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM IAWG) has achieved much in establishing comparability of measurement results. Impressive work has been done on comparison exercises related to real-world problems in fields such as ecology, food, or health. In more recent attempts, measurements and comparisons were focused on calibration solutions which are the basis of most inorganic chemical measurements. This contribution deals with the question of how to achieve full and transparent SI traceability for the values carried by such solutions. Within this framework, the use of classical primary methods (CPMs) is compared to the use of a primary difference method (PDM). PDM is a method with a dual character, namely a metrological method with a primary character, based on the bundling of many measurement methods for individual impurities, which lead to materials with certified content of the main component. As in classical methods, where small corrections for interferences are accepted, in PDM, many small corrections are bundled. In contrast to classical methods, the PDM is universally applicable to all elements in principle. Both approaches can be used to certify the purity (expressed as mass fraction of the main element) of a high-purity material. This is where the metrological need of National Metrology Institutes (NMIs) for analytical methods meet the challenges of analytical methods. In terms of methods, glow discharge mass spectrometry (GMDS) with sufficient uncertainties for sufficiently small impurity contents is particularly noteworthy for the certification of primary transfer standards (PTS), and isotope dilution mass spectrometry (IDMS), which particularly benefits from PTS (back-spikes) with small uncertainties, is particularly noteworthy for the application. The corresponding relative uncertainty which can be achieved using the PDM is very low (< 10−4). Acting as PTS, they represent the link between the material aspect of the primary calibration solutions and the immaterial world of the International System of Units (SI). The underlying concepts are discussed, the current status of implementation is summarised, and a roadmap of the necessary future activities in inorganic analytical chemistry is sketched. It has to be noted that smaller measurement uncertainties of the purity of high-purity materials not only have a positive effect on chemical measurements, but also trigger new developments and findings in other disciplines such as thermometry or materials science. KW - Inorganic chemical analysis KW - Primary transfer standards (PTSs) KW - Traceability KW - Classical primary measurement method (CPM) KW - Primary difference measurement method (PDM) KW - Metrology in chemistry PY - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-572743 SN - 1618-2642 SN - 1618-2650 VL - 415 SP - 3057 EP - 3071 PB - Springer CY - Berlin AN - OPUS4-57274 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -