TY - CONF A1 - Pavlovic, Mato A1 - Müller, Christina A1 - Heckel, Thomas A1 - Zoёga, Andreas T1 - Reliability analysis of the ultrasonic inspection system for the inspection of hollow railway axles N2 - Axles are safety critical train components that are subjected to significant cyclic loading during operation. If the crack is initiated in the axle, cyclic loading will lead to crack propagation. To maintain structural integrity, axles must be periodically inspected for fatigue cracks in the material. Deutsche Bahn uses mechanized ultrasonic inspection system to inspect hollow railway axles. The inspections are performed from the bore surface, using several conventional transducers with different incident angles, inspecting the axle along the entire length. As with the every safety critical system, the reliability of these inspections must be determined with regard to their flaw detection capabilities. Traditionally this is done according to the relevant standards for railway vehicles. To investigate the capability of the NDT system more thoroughly, we want to evaluate the capability of the inspection system to detect flaws by means of probability of detection (POD) curves. It will be shown that other parameters, beside the size of the crack, for example crack position in the axle, influence the detection of the crack. The influence of these parameters was evaluated using ultrasonic simulation. The evaluation served as an input for the manufacturing of the flaws in the real scale axle. Once these axles are inspected and the data evaluated, using data from both measurement and simulation, we will express the POD of the crack as function of influencing parameters using the multiparameter POD model. T2 - 19th Wolrd Conference on Nondestructive Testing CY - Munich, Germany DA - 13.06.2016 KW - POD KW - Railway KW - Axle KW - Safety KW - Reliability KW - Ultrasonics PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-366996 VL - 2016/158 SP - Tu.3.D.5 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-36699 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Völz, Uwe A1 - Mrasek, Heinz A1 - Heckel, Thomas T1 - Querfehlerprüfung an anisotropen Engspaltschweißnähten mit Gruppenstrahlern N2 - Die Prüfung von anisotropen Schweißnähten auf Querfehler stellt auch heute noch eine Herausforderung für die Ultraschallprüfung dar. Das gilt insbesondere für das Auffinden kleiner rissartiger Fehlstellen in einer unbeschliffenen Wurzel. Ursachen dafür sind zum einen das ausgeprägte Beugungs-, Streuungs- und Reflexionsverhalten solcher Nähte und zum anderen die störenden Formanzeigen aus dem Wurzelbereich, die sicher von den Fehlstellen unterschieden werden müssen, um Fehlinterpretationen bei der Bewertung der Anzeigen zu vermeiden. In der vorliegenden Arbeit werden an einer 85 mm dicken und 6 bis 10 mm breiten Engspaltschweißnaht mit stängelkristalliner Struktur rissartige Testfehler in Form erodierter Nuten untersucht. Die 2 und 4 mm tiefen Nuten sind mit 5 mm Länge kürzer als die Wurzelbreite. Die Wurzel ist nicht beschliffen und hat eine Überhöhung von ca. 2 mm. Ziel ist es, die Fehlstellen von den Form- und Gefügeanzeigen zu unterscheiden und sicher zu detektieren. Eine Größenbestimmung ist nicht vorgesehen. Durch den Einsatz der Gruppenstrahlertechnik ist es möglich, optimale Einschallparameter zu finden, mit denen diese Aufgabe gelöst werden kann. Es werden zwei azimutal schwenkende lineare Gruppenstrahlerprüfköpfe mit Vorsatzkeil in SE-Technik verwendet, die so auf beiden Seiten der Schweißnaht angeordnet sind, dass sich ihre Schallfelder unabhängig von der Einschallrichtung in der Schweißnahtwurzel überlagern. Damit ist es möglich, optimale Einschallwinkel für das Prüfproblem zu finden und in einer Prüffahrt gleichzeitig in beiden Einschallrichtungen längs der Schweißnaht zu prüfen. T2 - DGZfP-Jahrestagung 2011 CY - Bremen, Germany DA - 30.05.2011 KW - Ultraschall KW - Gruppenstrhaler KW - Anisotropie KW - Austenit KW - Nickellegierung KW - Querfehler KW - Schweißnaht PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-252777 SN - 978-3-940283-33-7 IS - DGZfP-BB 127 (P49) SP - 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-25277 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Heckel, Thomas A1 - Boehm, Rainer A1 - Gohlke, Dirk T1 - Optimierung von Ultraschall-fokusprüfköpfen beim Einsatz an stark gekrümmten Oberflächen N2 - Bei der Prüfung von gekrümmten Bauteilen in Tauchtechnik muss man die Veränderung des Schallfeldes durch die Form der Oberfläche berücksichtigen. Insbesondere bei hochauflösenden Ultraschallprüfungen mit Fokusprüfköpfen kommt es hierbei zu drastischen Verzerrungen des Schallfeldes. Diese Verzerrungen sind bei der Empfindlichkeitseinstellung sowie bei der Auslegung von Fokuspunkt- und Spurabstand zu berücksichtigen, um eine ausreichende Prüfempfindlichkeit zu erreichen. Es werden Beispiele von Simulationsrechnungen an typischen Prüfanordnungen vorgestellt. T2 - DGZfP-Jahrestagung 2011 CY - Bremen, Germany DA - 30.05.2011 KW - Fokusprüfköpfe KW - Gekrümmte Oberflächen PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-253841 SN - 978-3-940283-33-7 IS - DGZfP-BB 127 (Poster 62) SP - 1 EP - 5 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-25384 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kotschate, Daniel A1 - Gohlisch, Stephan A1 - Heckel, Thomas A1 - Sondermann, F. T1 - Bildgebende Ultraschallhandprüfeinrichtung für die Ausbildung N2 - Um den vermehrten Einsatz von mechanisierten Prüfeinrichtungen bei der Ultraschallprüfung in der Ausbildung Rechnung zu tragen, ist es wünschenswert, dieses Themenfeld bereits zu einem frühen Zeitpunkt in die Ultraschallkurse zu integrieren. Aus diesem Grund wurde für die Ausbildung bei der DGZfP in Zusammenarbeit mit der BAM ein teilmechanisiertes Ultraschall-Prüfsystem entwickelt. Das System basiert auf einem handelsüblichen Ultraschallgerät für die Handprüfung und einem Netbook-Computer. Die berührungslose Positionserfassung wird über den Blenden-Ausgang des Ultraschallgerätes getriggert und die Daten werden mittels Infrarot- und Bluetoothtechnik übertragen. Dies ermöglicht einen kompakten und portablen Aufbau mit kurzen Einrichtzeiten, der sich im Rahmen einer Lehrveranstaltung effektiv einsetzen lässt. Die Ergebnisdarstellung erfolgt mit C-Bildern. An einfachen Übungsstücken können die Kursteilnehmer, dicht an die Handprüfung angelehnt, die Methoden und Randbedingungen einer mechanisierten Prüfung erfahren. T2 - DGZfP-Jahrestagung 2011 CY - Bremen, Germany DA - 30.05.2011 KW - Ultraschallprüfsystem KW - Ultraschallprüfung PY - 2011 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-253826 SN - 978-3-940283-33-7 IS - DGZfP-BB 127 (Poster 89) SP - 1 EP - 4 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) AN - OPUS4-25382 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hosseini, Seyed M.H. A1 - Ségur, D. A1 - Boehm, Rainer A1 - Gohlke, Dirk A1 - Heckel, Thomas A1 - Riemer, S. A1 - Brackrock, Daniel A1 - Gaal, Mate T1 - Characterization and optimization of ultrasonic tests for inspection of fiber-reinforced plastic composites in energy related applications N2 - Applications of fibre reinforced plastic (FRP) composites in modern industries are increasing due to their considerable advantages such as light weight and excellent mechanical properties. Accordingly, importance of operational safety of modern structures made of advanced composites by ensuring the material quality has led to increasing demands for development of non-destructive evaluation (NDE) systems. In the context of a European project entitled “Validated Inspection Techniques for Composites in Energy Applications” (VITCEA), the aim is to develop and validate traceable procedures for novel NDE techniques with contrasting damage detection capabilities in energy related applications such as wind and marine turbine blades, nacelles, oil and gas flexible risers. Accordingly, VITCEA focuses on optimization of ultrasonic tests (UTs) for quantitative defect detection and quality characterization of FRP structures. In this context, the present study describes the ultrasound field in heterogeneous composite materials. The theoretical predictions are compared with simulation results obtained from CIVA a software package dedicated to NDT simulations based on the asymptotic ray theory. T2 - WCNDT 2016 - - 19th World Conference on Non-Destructive Testing CY - München DA - 13.06.2016 KW - Ultrasonic tests KW - Composite KW - Wave propagation KW - Analytical approach PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-356398 SP - We.4.D.5, 1 EP - 8 AN - OPUS4-35639 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kotschate, Daniel A1 - Gohlke, Dirk A1 - Heckel, Thomas T1 - Three dimensional examination of directivity pattern in immersion tank testing N2 - High resolution examination of safety-relevant parts in immersion tank testing with focussing probes is forming a main topic of modern non-destructive testing. For the usage of complex reconstruction methods and algorithms, an individual and detailed knowledge about the transmission behaviour of the used probes is essential, as this has a significant influence on the results of data reconstruction. Especially the knowledge about position and diameter of the focal point is needed to achieve the highest possible sensitivity. Through the individual position of the beam axis within the examined volume, a four dimensional metro logical determination of the acoustical pressure (x, y, z, t) is necessary. With the measured data it is possible to draw interferences about the sound field and acoustical pressure distribution. The presented work realized a method of automatic determination of the beam axis, the position of focal point and the focal diameter to support individual testing setups and transducer characterization. T2 - 7th International Symposium on NDT in Aerospace CY - Bremen, Germany DA - 16.11.2015 PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-339995 AN - OPUS4-33999 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schadow, Florian A1 - Brackrock, Daniel A1 - Gaal, Mate A1 - Heckel, Thomas T1 - Ultrasonic inspection and data analysis of glass- and carbon-fibre-reinforced plastics N2 - Non-destructive testing (NDT) helps to find material defects without having an influence on the material itself. It is applied as a method of quality control, for online structural health monitoring, and for inspection of safety related components. Due to the ability of automation and a simple test setup ultrasonic testing is one major NDT technique next to several existing options. Whereas contact technique allows the use of higher frequencies of some MHz and phased array focusing, air-coupled ultrasonic testing (ACUT) shows different advantages. Most significant for ACUT is the absence of any coupling fluid and an economical test procedure respective time and costs. Both contact technique and ACUT have been improved and enhanced during the past years. One important enhancement is the development of airborne transducers based on ferroelectrets, like charged cellular polypropylene (cpp), which makes the application of any matching layers being mandatory in conventional piezoelectric transducers unnecessary. In this contribution we show ultrasonic inspection results of specimens made of carbon- and glass-fibre-reinforced plastic. These specimens include defects represented by drill holes and artificial delaminations of various size and depth. We compare inspection results achieved by using contact technique to those achieved by ACUT. For ACUT, conventional piezoelectric transducers and transducers based on cpp were used, both focused as well as non-focused types. Contact inspections were performed with a multi-channel matrix array probe. Once the inspection data is recorded it can be analysed in order to detect and evaluate defects in the specimen. We present different analysing strategies and compare these regarding detection rate and sizing of defects. T2 - 3rd International Symposium on Fatigue Design and Material Defects, FDMD 2017 CY - Lecco, Italy DA - 19.09.2017 KW - Ultrasonic testing KW - Air-coupled KW - Carbon-fibre-reinforced plastic KW - Glass-fibre-reinforced KW - Material inspection KW - Defect sizing PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-434802 DO - https://doi.org/10.1016/j.prostr.2017.11.092 SN - 2452-3216 VL - 7 SP - 299 EP - 306 PB - Elsevier B.V. AN - OPUS4-43480 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maierhofer, Christiane A1 - Krankenhagen, Rainer A1 - Röllig, Mathias A1 - Hosseini, Seyed A1 - Heckel, Thomas A1 - Gaal, Mate A1 - Schadow, Florian A1 - Brackrock, Daniel A1 - Gower, M. A1 - Lodeiro, M. A1 - Baker, G. T1 - Quantitative Bewertung künstlicher und natürlicher Fehler in Faserverbundwerkstoffen mit aktiver Thermografie und Ultraschall N2 - Im EMRP-Projekt VITCEA werden komplementäre ZFP-Verfahren zur Prüfung von Faserverbundwerkstoffen weiterentwickelt und validiert. In diesem Beitrag werden Ergebnisse verschiedener Techniken der aktiven Thermografie und des Ultraschalls vorgestellt. Die Nachweisempfindlichkeiten bezüglich künstlicher und natürlicher Fehler mit unterschiedlichen lateralen Ausdehnungen und in verschiedenen Tiefen werden miteinander verglichen. T2 - DGZfP Jahrestagung 2017 CY - Koblenz, Germany DA - 22.05.2017 KW - CFK KW - GFK KW - Aktive Thermografie KW - Phased Array Ultraschall KW - Luftultraschall PY - 2017 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-410902 SN - 978-3-940283-85-6 VL - BB 162 SP - Di1B1, 1 EP - Di1B1, 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung e. V. AN - OPUS4-41090 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -