TY - CONF A1 - Strangfeld, Christoph A1 - Kruschwitz, Sabine A1 - Wöstmann, Jens A1 - Munsch, Sarah Mandy A1 - Hase, Felix T1 - Moisture in screed: a non-destructive multi-sensor approach N2 - Eight different screed types are tested including two different sample heights of 35 and 70 mm. The moisture of the four cement based and four sulphate based screeds are monitored during hydration and evaporation. All samples are stored in a climatic chamber at 23◦ C and 50 % relative humidity. Embedded sensors like temperature arrays, humidity sensor arrays, and multi-ring electrodes are embedded in the samples to yield a detailed moisture evolution with high depth resolution. Furthermore, nuclear magnetic resonance is used to quantify the water content at different depths. This multi-sensor approach allows a comprehensive monitoring of the moisture and its gradient in the different screed samples. This yields a deeper insight into the hydration, moisture convection, and diffusion processes. T2 - 8th European Workshop On Structural Health Monitoring CY - Bilbao, Spain DA - 05.07.2016 KW - NMR KW - Screed KW - Embedded sensors KW - Moisture KW - Corresponding relative humidity PY - 2016 N1 - Geburtsname von Munsch, Sarah Mandy: Nagel, S. M. - Birth name of Munsch, Sarah Mandy: Nagel, S. M. SP - 1 EP - 11 AN - OPUS4-36814 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hase, Felix T1 - Design und Aufbau verschiedener Messysteme zur Ermittlung des Feuchtigkeitsprofiles von Estrich N2 - Zur Bestimmung des Feuchtigkeitsgehalts von Fußbodenstrich werden bis zu diesem Zeitpunkt hauptsächlich die Calcium-Carbid Methode (CM) oder das thermogravimetrische Darr-Verfahren angewendet. Für die Anwendung beider Methoden muss der Estrich zerstört werden. Die aus der Messung gewonnenen Messdaten sind jedoch nur einmalig und punktuell. Damit sind diese Verfahren nur bedingt aussagefähig. Des Weiteren variieren die Messdaten von Estrichtyp zu Estrichtyp. Zusammen mit Partnern aus der Forschung und Industrie wird an der Bundesanstalt für Materialforschung und -prüfung (BAM) eine Messkampagne durchgeführt, mit dem Ziel, verschiedene Prüfverfahren zur Bestimmung des Feuchtigkeitsgehalts hinsichtlich ihrer Genauigkeit und Sensitivität zu untersuchen. Hierfür sind zwei neue Messsysteme entwickelt worden, welche auf der zerstörungsfreien Messung basieren. Dafür werden in den Estrich zum einen Sensoren, welche die relative Luftfeuchte messen und zum anderen eine Multiringelektrode, eingebettet. Die Messungen finden in verschiedenen Estricharten und Materialdicken statt, welche bei Normklima mit einer Temperatur von 23 °C und einer relativen Luftfeuchtigkeit von 50 % trocknen. Aus den erhaltenen Messdaten kann ein zeitliches und tiefenabhängiges Feuchtigkeitsprofil des Estrichs erstellt werden. KW - Korrespondierende relative Luftfeuchte KW - Ausgleichsfeuchte KW - Estrichfeuchte KW - Feuchtemesstechnik PY - 2016 SP - 1 CY - Berlin AN - OPUS4-37698 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Strangfeld, Christoph A1 - Prinz, Carsten A1 - Hase, Felix A1 - Kruschwitz, Sabine T1 - Data of embedded humidity sensors, sample weights, and measured pore volume distribution for eight screed types N2 - Four cement-based and four calcium-sulphate-based screed types are investigated. The samples have a diameter of 300 mm and a height of 35 or 70 mm. Up to ten humidity sensors are embedded directly during the concreting of the screed samples. Thus, the humidity over the sample height is monitored during hardening, hydration, evaporation, and oven drying. Furthermore, the screed samples are weighed during every measurement to determine the total mass and the corresponding moisture loss. To define the pore system precisely, mercury intrusion porosimetry as well as gas adsorption is performed. According to the data, the entire pore volume distribution is known. The measured pore diameters range from 0.8 nm to 100 µm and the total porosity of the examined screeds ranges between 11% and 22%. Based on these measurement data, moisture transport, pore saturation as well as sorption isotherms and their hysteresis may be calculated quantitatively as described in “Monitoring of the absolute water content in porous materials based on embedded humidity sensors” (Strangfeld and Kruschwitz, 1921). KW - Concrete and screed KW - Embedded humidity sensors KW - Pore volume distribution KW - Material moisture PY - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-462339 SN - 2352-3409 VL - 21 SP - 8 EP - 12 PB - Elsevier CY - Amsterdam AN - OPUS4-46233 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -