TY - GEN A1 - Dörfel, Ilona A1 - Steinborn, Gabriele A1 - Langner, Jeanette A1 - Krietsch, Arne A1 - Seeger, Stefan A1 - Österle, Werner A1 - Schmidt, Martin A1 - Bresch, Harald T1 - Dossier on titanium dioxide - Part 1/1 - NM 105 N2 - In November 2007, OECD’s Working Party on Manufactured Nanomaterials (WPMN) launched the Sponsorship Programme for the Testing of Manufactured Nanomaterials (hereafter the Testing Programme). The objective was to conduct specific tests, relevant to human health and environmental safety endpoints, on a variety of manufactured nanomaterials (MN). The outcomes of the Testing Programme were intended to assess the applicability of the existing test guidelines1 to nanomaterials, as well as to provide useful information on any intrinsic properties of MNs, which are different from the same bulk material with greater external dimensions. Understanding the properties of NMs is crucial to choose appropriate strategies for hazard identification, risk assessment or risk management measures. The Testing Programme involved delegations from OECD member countries, some non-member economies and other stakeholders. The broad international representation, from a range of delegations enabled the programme to pool expertise and resources without which this programme would not have been possible. KW - Nanomaterial KW - Nanoparticle KW - Sponsorship programme KW - Nano characterization PY - 2015 UR - http://www.oecd.org/env/ehs/nanosafety/dossier-on-silver-nanoparticles-part1-1.htm IS - 54 SP - 27 CY - Paris AN - OPUS4-35430 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Measurement of particle emission during brake dynamometer tests N2 - Aerosol emissions from brake pads are evolving into the focus of industrie and regulation. Many institutes are extending their dynamometer test stands with aerosol measurement equipement. While this is in general a good developement, the details of aerosol measurement and the special problems in the case of brake pad emissions need some special attention. The instrumentation can not be used out of the box and the important parameters will be highlighted in this presentation. T2 - Role of Third Bodies in Tribology CY - Berlin, Germany DA - 09.06.2016 KW - brake KW - Bremsen KW - nano KW - nanoparticle KW - tribology KW - Tribologie KW - ultrafine KW - dust KW - Staub KW - Nanopartikel KW - Nano PY - 2016 AN - OPUS4-36453 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Asbach, C. A1 - Held, A. A1 - Kiendler-Scharr, A. A1 - Scheuch, G. A1 - Schmid, H.-J. A1 - Schmitt, S. A1 - Schumacher, S. A1 - Wehner, B. A1 - Weingartner, E. A1 - Weinzierl, B. A1 - Bresch, Harald A1 - Seeger, Stefan A1 - u.a., T1 - Positionspapier der Gesellschaft für Aerosolforschung zum Verständnis der Rolle von Aerosolpartikeln beim SARS-CoV-2 Infektionsgeschehen N2 - Dass Viren sich über Aerosolpartikel ausbreiten können, wurde bereits in vielen Studien gezeigt. Als Aerosol bezeichnet man ein Gemisch aus Luft mit darin verteilten festen oder flüssigen Partikeln. Ein Aerosol ist dabei immer dynamisch, da Partikel neugebildet, in oder mit der Luft transportiert und aus der Luft entfernt werden oder sich im luftgetragenen Zustand verändern. Zum Verständnis der Rolle von Aerosolpartikeln als Übertragungsweg von SARS-CoV-2 ist daher die Kenntnis der verschiedenen Prozesse in einem Aerosol von besonderer Bedeutung. Mit diesem Papier möchte die GAeF einen Beitrag dazu leisten, den momentan so häufig anzutreffenden Begriff „Aerosol“ sowie die relevanten Aerosolprozesse anschaulich darzustellen und zu erläutern. Dabei wird im Rahmen dieses Papiers nur auf die wesentlichen Grundlagen eingegangen. Für ein tiefergehendes Verständnis der teilweise komplexen Prozesse sei auf die angeführte Sekundärliteratur verwiesen. Das Papier fasst eine Vielzahl von Studien zur Entstehung von virenbeladenen Aerosolpartikeln sowie deren Ausbreitung zusammen. Darauf basierend kann festgestellt werden, dass ausgeatmete Aerosolpartikel auch bei der Corona-Pandemie eine prominente Rolle bei der Verbreitung der Viren spielen. Abschließend geht dieses Papier auf mögliche Maßnahmen zur Verringerung der Ausbreitung von Aerosolpartikeln ein. Die diskutierten Maßnahmen orientieren sich an der derzeitigen öffentlichen Diskussion und beinhalten entsprechend die folgenden Punkte: Lüften, Luftreiniger, Lüftungsanlagen und Masken. Es werden Hinweise zum richtigen und sinnvollen Einsatz dieser Maßnahmen gegeben. Aerosolpartikel haben Größen zwischen ca. 0,001 und mehreren 100 Mikrometern (und nicht wie in vielen Publikationen derzeit definiert < 5μm) und verteilen sich mit Luftströmungen relativ schnell, auch über größere Distanzen. Größere Aerosolpartikel sinken – abhängig von ihrer Größe und Dichte – zu Boden; kleine Aerosolpartikel können hingegen sehr lange in der Luft verbleiben (s. Kapitel 3). Jeder Mensch stößt durch die Atmung sowie beim Sprechen, Husten und Niesen flüssige Aerosolpartikel unterschiedlicher Größen aus (s. Kapitel 4). Ist eine Person mit einem Virus, wie z. B. SARS-CoV-2, infiziert, so können diese Aerosolpartikel Viren enthalten, die in die Luft gelangen und von anderen Personen eingeatmet werden können. SARS-CoV-2 hat eine Größe von 0,06 bis 0,14 Mikrometer, die exhalierten flüssigen Aerosolpartikel sind hingegen größer. Die flüssigen Aerosolpartikel können aber je nach Umgebungsbedingungen durch Verdunstung schrumpfen (s. Kapitel 3.3). Für den Partikeltransport und die Partikelabscheidung ist dabei jeweils die aktuelle Partikelgröße relevant. Das höchste Infektionsrisiko besteht in geschlossenen Innenräumen, da sich hierin Aerosolpartikel anreichern können. Insbesondere hier sind entsprechend Maßnahmen zu treffen, die eine Reduktion der Aerosolpartikelkonzentration ermöglichen. Vor dem Hintergrund der Aerosolwissenschaften ordnet die GAeF die aktuellen Maßnahmen zur Eindämmung der Pandemie wie folgt ein: • Prinzipiell gilt: Keine Maßnahme kann für sich alleine funktionieren! Das Zusammenspiel der verschiedensten Maßnahmen ist nach derzeitigem Wissensstand der beste Weg zur Minimierung des Infektionsrisikos. • Abstand halten ist wichtig, denn mit zunehmendem Abstand werden direkt ausgeatmete Viren verdünnt, und die Wahrscheinlichkeit sich anzustecken sinkt. Der vielfach vorgeschriebene Mindestabstand kann als Anhaltspunkt dienen, sollte aber insbesondere bei längeren Zusammenkünften und auch in Innenräumen mit verringerter Luftbewegung vergrößert und durch weitere Maßnahmen (s.u.) ergänzt werden. • Masken helfen, einen Teil der exhalierten Partikel (und Viren) zu filtern. Dadurch sinkt die Konzentration der exhalierten Partikel (und Viren) in einem Raum und damit das Infektionsrisiko. Hierbei ist zu beachten, dass die ausgeatmeten Aerosolpartikel durch anhaftende Feuchtigkeit relativ groß sind und somit auch von einfachen Masken effizient zurückgehalten werden können. Da diese Partikel aber mit längerer Verweilzeit in der Raumluft schrumpfen, sind einfache Mund-Nasen-Bedeckungen für den Selbstschutz weniger effizient. Hierfür sind Atemschutzmasken erforderlich, die auch für feine Partikel eine hohe Abscheidung zeigen, z. B. der Klassen FFP2, N95 oder KN95. Diese sind sowohl für den Selbst- als auch den Fremdschutz effizient, sofern sie über kein Ausatemventil verfügen. Masken mit Ausatemventil dienen hingegen nur dem Selbstschutz und widersprechen daher dem Solidaritätskonzept, dass Mitmenschen durch kollektives Maskentragen geschützt werden. • Gesichtsvisiere, die ohne zusätzliche Verwendung von Masken eingesetzt werden, sind hinsichtlich Aerosolpartikeln weitgehend nutzlos, da die Luft mit Partikeln (und Viren) ungefiltert um die Visiere herumströmt. Gesichtsvisiere werden im klinischen Alltag zusätzlich zu Masken getragen, um Tröpfcheninfektion über die Schleimhäute der Augen zu verhindern. Ebenfalls weitgehend unwirksam gegen die Aerosolverbreitung in Innenräumen sind mobile oder fest installierte Plexiglasbarrieren. Diese können nur kurzfristig die kleinräumige Ausbreitung eines Aerosols, z. B. im Kassenbereich eines Supermarkts, verhindern, bieten aber längerfristig keinen Schutz. Gesichtsvisiere und Plexiglasscheiben dienen im Wesentlichen als Spuck- und Spritzschutz gegenüber großen Tröpfchen. • Im Freien finden so gut wie keine Infektionen durch Aerosolpartikel statt. Allerdings können Tröpfcheninfektionen auftreten, insbesondere in Menschenansammlungen, wenn Mindestabstände nicht eingehalten und/oder keine Masken getragen werden. In geschlossenen Räumen ist Lüften unerlässlich, um die ausgeatmete Luft in einem Raum durch frische Luft von draußen zu ersetzen. Häufiges Stoß- und Querlüften sind dabei vergleichbar effektiv wie dauernd das Fenster vollständig geöffnet zu lassen. Aus energetischer Sicht ist Stoß- oder Querlüften insbesondere im Winter allerdings effizienter. CO2-Monitore können bei der Überwachung der Luftqualität in Innenräumen helfen. Sie zeigen an, wann gelüftet werden sollte und wann die Luft in einem Raum während des Lüftens ausreichend gewechselt ist. Sie können jedoch nur als Indikator verwendet werden und verhindern selbst bei Einhaltung der vorgeschlagenen CO2-Grenzkonzentrationen keine direkte Infektion durch unmittelbar benachbarte Personen. • Luftreiniger können einen sinnvollen Beitrag leisten, um die Partikel- und Virenkonzentration in einem Raum zu reduzieren. Bei der Beschaffung von Luftreinigern muss darauf geachtet werden, dass diese für den betrachteten Raum und die betrachtete Anwendung ausreichend dimensioniert sind, um die Partikel- und Virenlast signifikant zu verringern. Dem Luftdurchsatz des Gerätes kommt dabei eine größere Bedeutung zu, als der reinen Effizienz des Filters. Aus energetischen und Kostenerwägungen kann die Verwendung hocheffizienter Filter sogar kontraproduktiv sein. Fest verbaute Lüftungsanlagen können ebenso sinnvoll sein, sofern sie die Luft filtern, um die Partikel- und Virenlast in einem Raum zu verringern. Hierbei ist es zur Vermeidung von Infektionen sinnvoll, diese möglichst mit 100 % Frischluft zu betreiben. Aus Sicht der Gesellschaft für Aerosolforschung besteht erheblicher Forschungsbedarf insbesondere an den interdisziplinären Grenzen zu Forschungsfeldern der Epidemiologie, Infektiologie, Virologie, Lüftungstechnik und Strömungsmechanik. Die Durchführung gezielter Studien sollte kurzfristig mit speziellen Förder- und Forschungsprogrammen ermöglicht werden. Dieses Papier wurde von Mitgliedern der Gesellschaft für Aerosolforschung verfasst und wird von einer Vielzahl internationaler Aerosolexperten unterstützt (s. Kapitel 8). Neben der vorliegenden Version existiert auch eine englischsprachige Übersetzung (siehe www.info.gaef.de). Sämtliche Abbildungen in diesem Papier stehen unter folgendem Link zum kostenlosen Download bereit: https://www.info.gaef.de/positionspapier. Bei jeder Verwendung ist „Gesellschaft für Aerosolforschung e. V.“ als Quelle zu nennen. KW - Covid KW - Corona KW - GAeF KW - Aerosole KW - Aerosolforschung PY - 2021 UR - https://www.info.gaef.de/_files/ugd/fab12b_a5f114a183cf4f27ab8ac713e8a5b8ef.pdf SP - 1 EP - 48 PB - Gesellschaft für Aerosolforschung CY - Köln AN - OPUS4-53954 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Asbach, C. A1 - Held, A. A1 - Kiendler-Scharr, A. A1 - Scheuch, G. A1 - Schmid, H.-J. A1 - Schmitt, S. A1 - Schumacher, S. A1 - Wehner, B. A1 - Weingartner, E. A1 - Weinzierl, B. A1 - Bresch, Harald A1 - Seeger, Stefan A1 - u.a., T1 - Position paper of the Gesellschaft für Aerosolforschung on understanding the role of aerosol particles in SARS-CoV-2 infection N2 - Many studies have already shown that viruses can spread via aerosol particles. An aerosol is a mixture of air with solid or liquid particles dispersed in it. To understand the role of aerosol particles as a transmission path of SARS-CoV-2, knowledge of the different processes in an Aerosol is therefore of particular importance. With this paper, GAeF would like to contribute to a better understanding of the term “aerosol” and the relevant aerosol processes. In the context of this paper only the essential basics will be discussed. For a deeper understanding of the partly complex processes, please refer to the literature mentioned at the end of the paper. The paper summarises a large number of studies on the formation of virus-laden aerosol particles and their spread. Based on this, it can be concluded that exhaled aerosol particles may play a prominent role in the spread of viruses in the corona pandemic. Finally, this paper discusses possible measures to reduce the spread of aerosol particles. The measures discussed are based on the current public debate including ventilation, air purifiers, HVAC systems and masks. Advice is given on the correct and sensible use of these measures. An aerosol is always dynamic, as particles are newly formed, transported in or with the air, removed from the air or change in the airborne state. Aerosol particles have sizes between approx. 0.001 and several 100 micrometres (and not < 5 μm as currently defined in many publications) and spread relatively quickly with air currents, even over longer distances. Larger aerosol particles sink to the ground, depending on their size and density, while small aerosol particles can remain in the air for a very long time (see Section 3). Every person emits liquid aerosol particles of various sizes through breathing and when speaking, coughing and sneezing (see Section 4). If a person is infected with a virus, such as SARS-CoV-2, these aerosol particles can contain viruses that can be released into the air and inhaled by other people. SARS-CoV-2 has a size of 0.06 to 0.14 micrometres, but the exhaled liquid aerosol particles are larger. The liquid aerosol particles can shrink by evaporation, depending on the ambient conditions (see Section 3.3). Particle size is relevant for particle transport and particle separation. The highest risk of infection exists in closed indoor spaces, as aerosol particles can accumulate there. Here in particular, appropriate measures must be taken to reduce the concentration of aerosol particles (see Section 5). Against the background of aerosol science, the GAeF classifies the current measures to contain the pandemic as follows: • In principle, no measure can work on its own! According to the current state of knowledge, the interaction of the most varied measures is the best way to minimise the risk of infection. • Keeping distance is important, because with increasing distance, directly exhaled viruses are diluted and the probability of infection decreases. The often prescribed minimum distance can be used as a guide, but it should be increased and supplemented by other measures (see below), especially for longer meetings and also indoors with reduced air movement. • Masks help to filter some of the exhaled particles (and viruses). This reduces the concentration of exhaled particles (and viruses) in a room and thus the risk of infection. It should be noted here that the exhaled aerosol particles are relatively large due to adhering moisture and can therefore also be efficiently retained by simple masks. However, since these particles shrink with longer dwell time in the room air, simple mouth-nose masks are less efficient for self-protection. Respiratory masks are required for this purpose, which show a high degree of separation even for fine particles, e.g. of classes FFP2, N95 or KN95. These are efficient for both self-protection and protection of others unless they have an exhalation valve. Masks with an exhalation valve, on the other hand, are only for self-protection and therefore contradict the solidarity concept that fellow human beings are protected by collective mask wearing. Face shields which are used without additional masks are largely useless with regard t• aerosol particles, as the air with particles (and viruses) flows unfiltered around the shields. In everyday clinical practice, facial shields are worn in addition to masks to prevent droplet infection via the mucous membranes of the eyes. Mobile or permanently installed Plexiglas barriers are also largely ineffective against the spread of aerosols indoors. These can only prevent the smallscale spread of an aerosol in the short term, e.g. in the checkout area of a supermarket, but offer no protection in the longer term. Face shields and Plexiglas panels essentially serve as spit and splash protection against large droplets. • Outdoors, there are practically no infections caused by aerosol transmission. However, droplet infections can still occur, especially in crowds, if minimum distances are not observed and/or masks are not worn. In closed rooms, ventilation is essential to replace the exhaled air in a room with fresh air from outside. Frequent airing and cross-ventilation is just as effective as leaving the window open all the time. From an energy point of view, however, it is more efficient to ventilate the room, especially in winter. CO2 monitors can help to monitor indoor air quality. They indicate when it is necessary to ventilate and when the air in a room has been sufficiently changed during ventilation. However, they can only be used as an indicator and even if the proposed CO2 limit concentrations are met, they do not prevent direct infection by people in the immediate vicinity. • Air purifiers can make a useful contribution to reducing the concentration of particles and viruses in a room. When procuring air purifiers, care must be taken to ensure that they are adequately dimensioned for the room and application in question in order to significantly reduce the particle and virus load. The air throughput of the unit is more important than the pure efficiency of the filter. For energy and cost reasons, the use of highly efficient filters can even be counterproductive. Permanently installed ventilation systems can also be useful, provided they filter the air to reduce the particle and virus load in a room. To avoid infections, it is advisable to operate them with 100 % fresh air if possible. From the point of view of the Gesellschaft für Aerosolforschung, there is a considerable need for research, especially at the interdisciplinary borders to research fields of epidemiology, infectiology, virology, ventilation technology and fluid mechanics. The implementation of targeted studies should be made possible at short notice with special funding and research programmes. This paper was written originally in German by members of the Gesellschaft für Aerosolforschung and is supported by a large number of international aerosol experts. Both the English and German version as well as all images in the paper are available for free download at the following link: https://www.info.gaef.de/positionspapier. The “Gesellschaft für Aerosolforschung e. V.” must be named as the source, whenever an image is used. KW - COVID KW - SARS KW - GAeF KW - Aerosol KW - Corona PY - 2021 UR - https://www.info.gaef.de/_files/ugd/fab12b_d8d88393f90240cdbea63c88c09887ef.pdf DO - https://doi.org/10.5281/zenodo.4350494 SP - 1 EP - 48 PB - Association for Aerosol Research CY - Köln AN - OPUS4-53955 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - El-Athman, Rukeia A1 - Bresch, Harald A1 - Muth, Thilo A1 - Rädler, Jörg A1 - Rühle, Bastian T1 - Datenmanagement im Nanomaterial-Labor: Einsatz von ELN-Software zur digitalen Transformation des Laboralltags N2 - Angesichts der zunehmenden Digitalisierung und dem Einsatz datenintensiver Methodiken in der Wissenschaft stehen Forschende vor der Herausforderung, stetig wachsende Datenmengen nachvollziehbar zu dokumentieren, langfristig zu speichern und für Dritte nachnutzbar zu machen. Um diesen Anforderungen gerecht zu werden, bietet sich die Nutzung von Software-Lösungen an, welche Forschungsdatenmanagement mit der digitalen Dokumentation von Laborinventar und Experimenten in elektronischen Laborbüchern (engl. electronic lab notebooks (ELN)) verknüpfen. KW - NanoPlattform KW - BAM Data Store KW - OpenBIS KW - Forschungsdatenmanagement KW - Research data management KW - Elektronisches Laborbuch KW - Electronic lab notebook (ELN) PY - 2023 UR - https://analyticalscience.wiley.com/content/article-do/datenmanagement-im-nanomaterial-labor SN - 0016-3538 IS - 9 SP - 24 EP - 26 PB - Wiley Analytical Science CY - Weinheim AN - OPUS4-59600 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - OECD TG 125 Particle size and size distribution of Nanomaterials N2 - This presentation was held in an OECD Webinar introducing the newly developed and published OECD TG 125 on particle size and size distribution. The presentation is explaining the structure if the TG 125 and addresses all included methods and methodologies in a short and understandable way for the broader public. The presentation includes sections about nano-particles and nano-fibres. T2 - Webinar Series on Testing and Assessment Methodologies CY - Online meeting DA - 07.02.2023 KW - Nano KW - Nanomaterials KW - OECD KW - Test guideline KW - Size PY - 2023 UR - https://www.oecd.org/chemicalsafety/nanomet/presentations-webinar-nanomaterials-particle-size-distribution-test-guideline-125.pdf AN - OPUS4-58447 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Bleeker, E. A1 - Visser, M. A1 - Groenewold, M. A1 - Blab, G. A1 - Brouwer, D. A1 - Sultan, Y. A1 - Gagnon, C. A1 - Wilkinson, K. A1 - Doa, M. A1 - Boyes, W. A1 - Kiyota, Y. A1 - Yanase, K. A1 - Holmqvist, J. A1 - Rasmussen, K. A1 - Sumrein, A. A1 - Clancy, S. A1 - Brown, S. A1 - Carlander, D. A1 - Murphy, L. A1 - Bresch, Harald A1 - Hund-Rinke, K. A1 - Igarashi, T. A1 - Riego-Sintes, J. A1 - Tentschert, J. T1 - Physical-chemical properties of nanomaterials: Evaluation of methods applied in the OECD-WPMN Testing Programme N2 - The Sponsorship Programme for the Testing of Manufactured Nanomaterials (further referred to as “the Testing Programme”) was concluded in March 2013, and the publication of the dossiers via the OECD website (www.oecd.org/science/nanosafety) started in June 2015. As indicated in the “Guidance manual for the testing of manufactured nanomaterials: OECD’s sponsorship programme”, after conclusion of the Testing Programme a next step is to consider “the status, need for, and coordination of further test development”. Parallel to concluding the final stages of the Testing Programme, a series of workshops have taken place, in which for different topics the applicability of existing OECD test guidelines for nanomaterials was discussed and the need for new ones analysed. One workshop focussed on physico-chemical methods, addressing in detail the relevance of each physico-chemical endpoint proposed in the Testing Programme for the regulation of nanomaterials. The methods were discussed in more general terms. However, as most of the proposed endpoints are new to the OECD Test Guidelines Programme, a much more detailed evaluation of the applied methods would be highly relevant. To this extent,the Netherlands volunteered to lead an initial detailed evaluation of the applicability of the test methods applied to determine the physico-chemical properties of different types of nanomaterials in the Testing Programme. This initial focus on physico-chemical properties was prompted by the essential need for an adequate and complete characterisation of nanomaterials to enable a further evaluation of their (toxicological) properties. A number of experts from several delegations volunteered to review and evaluate the methods applied to determine the physico-chemical properties of the nanomaterials in the Testing Programme. KW - Nanomaterialien KW - Nano KW - Nanopartikel KW - Charakterisierung KW - OECD KW - Nanomaterials PY - 2016 UR - http://www.oecd.org/env/ehs/nanosafety/publications-series-safety-manufactured-nanomaterials.htm IS - 65 SP - 1 EP - 43 CY - Paris AN - OPUS4-38495 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - OECD-WPMN sponsorship programme dossiers - a review of the results for particle size N2 - The Organization for Economic Co-operation and Development (OECD) established the Working Party on Manufactured Nanomaterials (WPMN) in 2006. The OECD-WPMN initiated the "Sponsorship Programme for the Testing of Manufactured Nanomaterials", where a defined set of manufactured nanomaterials is tested for their physical/chemical properties, their toxicological potential and their environmental fade. The results of this program have been declassified in June 2015. Having a big set of independent measurements for one endpoint/measurand, has the advantage of really independent comparision of methods. It is surprising what these few data sets already delivered. Nevertheless the amount of data in the OECD-dossiers is still not enough. While we have a lot of data for titanium dioxide, we have only one data set for zinc oxide and very weak data sets for silver nanoparticles. This limits the useablility of the data sets. Regarding the quality of the data, we have seen a very good agreement of TEM and SMPS. This leads to the advice that we should have results for these two methods for each nanomaterial in the sponsorship programme. Another outcome of this draft review is, that currently we cannot compare measurements of agglomerates. This also prohibits the use of DLS as a standard method for size determination. T2 - European Aerosol Conference CY - Tours, France DA - 05.09.2016 KW - OECD KW - Nanopartikel KW - Nano KW - Nanoparticle KW - Nanomaterials PY - 2016 AN - OPUS4-38568 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - OECD Prüfrichtlinie für die Größenbestimmung von Nanomaterialien N2 - Erste Ergebnisse des Projektes "OECD Prüfrichtlinie für die Größenbestimmung von Nanomaterialien" mit Vorstellung der beteiligten Fachbereiche. T2 - Expertenaustausch BAM-BMU-BMWi CY - Berlin, Germany DA - 01.06.2018 KW - Nano KW - OECD KW - Nanopartikel KW - Nanomaterial KW - Größenbestimmung PY - 2018 AN - OPUS4-45110 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - OECD-Prüfrichtlinie zur Größenbestimmung von hergestellten Nanomaterialien N2 - Impulsvortrag für den Beirat des Themenfeldes Umwelt über die in Erstellung befindliche OECD Prüfrichtlinie für die Größenbestimmung von künstlich hergestellten Nanomaterialien. T2 - Sitzung des Beirates des Themenfelds Umwelt 2018 CY - Berlin, Germany DA - 26.02.2018 KW - Nano KW - OECD KW - Prüfrichtlinie KW - Nanopartikel KW - Nanomaterial PY - 2018 AN - OPUS4-45111 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - OECD Test Guideline on particle size and size distribution of manufactured nanomaterials N2 - The properties of nanomaterials are influenced not only by their chemical composition but also by physical properties (such as size, geometry and crystal structure). For the reliable determination and assessment of behaviour and effects of nanomaterials as well as for the determination of the exposure of humans and environment a comprehensive physical-chemical characterization of nanomaterials is essential. This is an important prerequisite to identify them as nanomaterials and to interpret and compare test results and - in future – to forecast interaction and effects of nanomaterials. In 2006, the OECD launched a sponsorship program for the testing of nanomaterials in which 11 nanomaterials were thoroughly investigated using a variety of methods. The aim of the project was, among other things, to find out where problems occur and where there are gaps in the measurement and test procedures and where are changes required. An important outcome of the sponsorship program was the finding that the OECD Test Guidelines should in several cases be extended to the specific needs in testing of nanomaterials. The existing standardized test methods of the OECD for physical-chemical characterization have not been developed for nanomaterials in particular. A high demand for an extension of the test guidelines was identified. Germany complied with the OECD's request in 2017 and has agreed to extend the “Test Guideline on Particle Size Distribution / Fiber Length and Diameter Distributions Test Guideline” for Manufactured Nanomaterials (MN). UBA commissioned BAM and BAuA with the preparation of the Test Guideline. The aim of the project is the development of a harmonized test protocol for a valid and reproducible determination of particle size and size distribution which is one of the most relevant physical-chemical properties for MNs. Different measuring methods provide different results for the size distribution of the particles. This is caused by the different measuring principles of the methods. Each method measures a specific parameter that ultimately determines particle size. First, the measured quantity differs for each method (Scattered light intensity, 2D image / projection, electric mobility, etc.). Second, the calculated diameters of the MN may differ (Feret Diameter, Area Projection, Mobility Diameter, Aerodynamic Diameter, Hydrodynamic Diameter). Third, a measuring method provides a size distribution which is measured either mass-based, surface-based or number-based. A conversion between the results requires additional parameters and thus possibly increases the measurement error. In addition to the technical differences, the individual parameters are strongly influenced by the structure and material of the nanoparticles. For example, a surface functionalization can lead to very different results in the size distribution. The suitability of measurement methods differs with the material of the MN. As a result, two very different results can be measured for the particle size distribution using two different methods, which are nevertheless both correct. Several large projects in recent years therefore concluded that nanomaterials should be characterized by at least two complementary method. Imaging techniques are regarded as one of these methods for the characterization, the complementary methods are supposed to be statistical methods. The different results for the size distribution of nanomaterials become problematic for the registration of new MN. A comparable and reproducible size distribution is a prerequisite for a standardized registration. In the future, the particle size distribution in the EU will also decide on the classification of a substance as a nanomaterial or as a non-nanomaterial. Especially in borderline cases, a standardized and comparable measurement methodology is therefore essential. T2 - BAM-PTB Workshop 2018 CY - Berlin, Germany DA - 14.05.2018 KW - Nano KW - OECD KW - Test Guideline KW - Size distribution KW - Particle PY - 2018 AN - OPUS4-45106 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Projekt Nano-TG110 N2 - Die OECD-TG110 mit dem Titel "Particle Size Distribution Fibre Length and Diameter Distribution" wurde 1981 erstellt und seither nicht überarbeitet. Nanomaterialien, wie Nanopartikel oder Nanofasern werden nicht adressiert, genausowenig wie moderne Messverfahren. Das hier vorgestellte Projekt hat zur Aufgabe, die Größenmessung von Nanopartikeln und Nanofasern in einer neuen Technical Guideline der OECD zu standardisieren. Es wird die Projekthistorie dargestellt, die Anforderungen, der aktuelle Projekt-Bearbeitungsstand wird beleuchtet und die weiteren Arbeiten werden kurz skizziert. T2 - Nano-Behördenklausur der Bundesoberbehörden CY - Berlin, Germany DA - 02.11.2017 KW - Nano KW - Nanopartikel KW - Nanoparticle KW - OECD KW - Guideline PY - 2017 AN - OPUS4-42737 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Nanomaterial characterisation - The long way to standardisation N2 - In 1981 the OECD published the Test Guideline on Particle size and size distribution. This TG is still a valid document for the measurement of particles all over the world. When nanomaterials gained importance, ISO set up a technical commitee for Nanotechnologies in 2005 and the OECD followed this step in 2006 with the Working Party on Manufactured Nanomaterials. In the following years ISO and OECD published several documents about nanomaterials and the systematisation developed. In 2017 it was finally clear that nanomaterials need to be adressed in another way than chemicals and in 2020 ECHA revised the REACH-Annexes accordingly and included nanomaterials. Unfortunately there is a little problem with this: Only a few applicable test guidelines exit for the measurement of the nanomaterials. Several test guidelines date from 1981 and do not address nanomaterials. The logical next step for the OECD would be to publish a series of test guidelines which are indeed currently prepared and will be shown in this talk. Finally there is an additional need for the future of NM standardisation: Digitalisation. T2 - Bilateral workshop with Uni Bermingham CY - Online meeting DA - 10.03.2021 KW - Nano KW - Standardisation KW - Test guideline KW - OECD KW - Nanomaterial PY - 2021 AN - OPUS4-53822 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Size matters! - Auf dem Weg zu einer neuen OECD Prüfrichtlinie zur Bestimmung der Partikelgröße und Anzahlgrößenverteilung von Nanomaterialien N2 - Vorstellung der Ergebnisse bei der Entwicklung einer neuen OECD Prüfrichtlinie zur Bestimmung der Partikelgröße und Anzahlgrößenverteilung von Nanomaterialien. Ergebnisse: Ideal sphärische Partikel sind gut und verlässlich mit vielen Methoden charakterisierbar. Reale (Nicht ideale) Materialien sind gut charakterisierbar, wenn eine gewisse Homogenität und Stabilität vorliegt. Stark inhomogene und stark agglomerierende Partikel liefern deutlich unterschiedliche Ergebnisse für verschiedene Methoden. Partikel mit geringen Größenunterschieden lassen sich mit allen Methoden gut charakterisieren. Partikel mit sehr deutlichen Größenunterschieden führen häufig zu einer Unterbewertung der kleineren Partikel. Vollautomatische Partikeldetektion bei elektronenmikroskopischen Aufnahmen ist z.Zt. noch stark fehleranfällig und kann daher nicht empfohlen werden. Es hat sich gezeigt, dass alle Methoden zur Bestimmung der Partikelgrößenverteilung Vor- und Nachteile haben. Es ist dringend zu empfehlen Größenverteilungen immer mit mindestens zwei unterschiedlichen Methoden zu bestimmen: Bildgebend und mit gute Anzahlstatistik. Verschiedene Durchmesser wurden in der TG-PSD mit einem Indexsystem versehen, welches zukünftig Verwechslungen zwischen unterschiedlichen Durchmessern vermeiden soll. Wird ein bestimmter Durchmesser benötigt (z.B. hydrodynamisch, aerodynamisch), muss die Methode passend gewählt werden. Eine Umrechnung von einem Durchmesser in einen anderen ist in der Regel fehlerbehaftet. Es wurde ein einheitliches Reporting-System in der TG-PSD eingeführt. T2 - Fachseminar des Umweltbundesamtes CY - Online meeting DA - 14.04.2021 KW - Nano KW - OECD KW - Prüfrichtlinie KW - Nanomaterial KW - BMU PY - 2021 AN - OPUS4-53823 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - OECD Prüfrichtlinie zur Bestimmung der Partikelgröße und Anzahlgrößenverteilung von Nanomaterialien N2 - Abschlusspräsentation des Projektes "OECD Prüfrichtlinie zur Bestimmung der Partikelgröße und Anzahlgrößenverteilung von Nanomaterialien" - Projektteil Nanopartikel. Es hat sich gezeigt, dass alle Methoden zur Bestimmung der Partikelgrößenverteilung Vor- und Nachteile haben. Es wird dringend empfohlen Größenverteilungen immer mit mindestens zwei unterschiedlichen Methoden zu bestimmen: Bildgebend und mit gute Anzahlstatistik. Verschiedene Durchmesser wurden in der TG-PSD mit einem Indexsystem versehen, welches zukünftig Verwechslungen zwischen unterschiedlichen Durchmessern vermeiden soll. Wird ein bestimmter Durchmesser benötigt (z.B. hydrodynamisch, aerodynamisch), muss die Methode passend gewählt werden. Eine Umrechnung von einem Durchmesser in einen anderen ist in der Regel fehlerbehaftet. Es wurde ein einheitliches Reporting-System in der TG-PSD eingeführt. T2 - Fachgespräch zur OECD - TG PSD - BMU BMWi BAM BAuA UBA CY - Online meeting DA - 10.09.2021 KW - Nano KW - OECD KW - Nanopartikel KW - Prürfrichtlinie KW - Nanomaterial PY - 2021 AN - OPUS4-53825 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - OECD Prüfrichtlinie 125 N2 - Diese Präsentation ist eine Einführung in die OECD TG 125 zur Bestimmung der Partikelgrößen von Nanomaterialien. Es wird auf die verchiedenen Probleme der Partikelgrößenbestimmung eingegangen wie z.B. verschiedene Oberflächenschichten, Äquivalenzdurchmesser und Verteilungsfunktionen. Gleichzeitig werden die neuen Begrifflichkeiten eingeführt, die in der TG 125 definiert neu werden. T2 - BAM Akademie Digitaler Info-Tag "Nano or not Nano" CY - Online meeting DA - 16.02.2023 KW - Nano KW - Partikel KW - Größe KW - Partikeldurchmesser KW - Äquivalenzdurchmesser PY - 2023 AN - OPUS4-58449 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Differentielles Mobilitäts Analyse System (DMAS) N2 - Die Bestimmung der Nanopartikelgrößen- und -formverteilung nach OECD TG 125 mit einem Differentiellen Mobilitäts Analyse System (DMAS), auch bekannt als SMPS, wird vorgestellt: - Generelles Messprinzip - Welchen Durchmesser misst die Methode? - Welche Partikel kann diese Methode messen? - Welche Informationen kann diese Methode liefern? - Wo stößt die Methode an ihre Grenzen? - Implementierung und Datenauswertung, - Reporting. Anschließend wurde eine Q&A-Session für DMAS/SMPS organisiert. T2 - BAM Akademie Digitaler Info-Tag "Nano or not Nano" CY - Online meeting DA - 16.02.2023 KW - Partikel KW - Nanopartikel KW - SMPS KW - Größenbestimmung KW - DMAS PY - 2023 AN - OPUS4-58450 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Standard Operating Procedures in the digital context N2 - The intention of the presentation is to inspire a discussion on the needs and challenges for the digitalisation of SOPs. SOPs are available for the disciplines of physical-chemical characterisation, for toxicology, for environmental applications and for exposure applications. Furthermore the SOPs need to be integrated in the regulatory framework and need to be detailed enough for the digital processing. This is highlighted in this presentation. T2 - Nanosafety 2020 CY - Online meeting DA - 07.10.2020 KW - Nano KW - SOP KW - NFDI KW - Digitalisation KW - Operating Procedure PY - 2020 AN - OPUS4-51491 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - GIXRF as method for the quantification of equally sized nanoparticel factions T2 - Aerosol Technology 2014 CY - Karlsruhe, Germany DA - 2014-06-16 PY - 2014 AN - OPUS4-33277 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - GIXRF as a method for the quantification of equally sized nanoparticle fractions T2 - Aerosol Technology 2014 CY - Karlsruhe, Germany DA - 2014-06-16 PY - 2014 AN - OPUS4-33278 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - OECD-WMPN Dossiers from the Sponsorship Programme - A first draft review of the physical/chemical testing results T2 - Europe Aerosol Conference CY - Milano, Italy DA - 2015-09-07 PY - 2015 AN - OPUS4-34408 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Core-shell systems - different cases N2 - Coating, stabilization layers, functionalization of particles or simple contamination are common variants of a core-shell system. For smaller nanoparticles this is of major importance. A particle with 16 nm diameter and a usual surface layer of 2 nm will have the same volume for the core as for the shell. In this case the material of the particle doesn’t have a clear definition. It is a common case that a particle consists of four different layers: Core, shell, stabilization layer and contamination. The properties of the particles differ according to this structure. For example silver particles might have a different dissolution rate for pure particles and for particles which are grown on top of a core. Different solubility or defined other properties of materials is a common reason for producing core-shell systems. Gold cores are surrounded by silica to stabilize them or to get a defined distance between the cores. Silica might be surrounded by gold and the silica dissolved afterwards. This delivers hollow shells. Another important example for core-shell systems are quantum dots. A small core is surrounded by a different material for increasing the photoluminescence. Furthermore there a stabilization layer is needed. The smallest part of the final particles is the initial core. The photoluminescence is based on this core, but the shells contain much more material. Categorization should address this. Core-shell systems are not covered by most of the existing decision trees for grouping. They are either regarded as special case or a singular layer. This disqualifies core-shell systems for grouping within the common models. There might be a very easy way to avoid this problem and even to combine some of the different decision trees. Starting the decision tree with the solubility of the outer shell and subsequently addressing the inner layers will be a pragmatic approach to solve the problem. If there is no shell, the categorization can start with a tiered approach or with the proposed “stawman” chemical categorization. If a shell is covering the surface there is a need to check if the shell is stable. If it is stable, the particle can be categorized based on this shell. If it is soluble, the ions need to be addressed as in the classic case. Furthermore the shell might increase the uptake by the cells. If the ions and the uptake are not critical the categorization can continue with the next layer. With this not perfect but pragmatic approach, the surface layers can be addressed with very limited additional efforts. Most criteria are based on classically tabulated data. Including a rating system like the precautionary matrix approach might even address the fact that some parameters are not always Yes/No, e.g. solubility, ion toxicity and uptake. T2 - OECD Expert Meeting on Grouping and Read Across for the Hazard Assessment of Manufactured Nanomaterials CY - Brussels, Belgium DA - 13.04.2016 KW - OECD KW - Nanoparticles KW - Nanomaterials KW - Grouping KW - Nano PY - 2016 AN - OPUS4-35774 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Seeger, Stefan A1 - Bresch, Harald T1 - Partikelemissionen aus Laserdruckern auf der Spur KW - Laserdrucker KW - Ultrafeinstaub KW - Partikelemission PY - 2008 SN - 0344-1733 SN - 1610-8256 IS - 4 SP - 26 EP - 28 PB - Vogel CY - Würzburg AN - OPUS4-18563 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Zerstörungsfreie Speziation deponierter Nanopartikel mit TXRF - NEXAFS T2 - 248. PTB-Seminar CY - Braunschweig, Germany DA - 2009-05-18 PY - 2009 AN - OPUS4-19646 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Nanoscale Particulate Emissions from Car-Brakes T2 - European Aerosol Conference 2009 CY - Karlsruhe, Germany DA - 2009-09-06 PY - 2009 AN - OPUS4-19902 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Nanoparticulate Emissions from Car-Brakes T2 - European Aerosol Conference CY - Karlsruhe, Germany DA - 2009-09-06 PY - 2009 AN - OPUS4-19906 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Nanoscale Particulate Emissions from Car-Brakes - Instrumental needs for the measurement T2 - International Conference on Workplace Aerosols CY - Karlsruhe, Germany DA - 2010-06-29 PY - 2010 AN - OPUS4-21773 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Orts Gil, Guillermo A1 - Natte, Kishore A1 - Drescher, Daniela A1 - Bresch, Harald A1 - Mantion, Alexandre A1 - Kneipp, J. A1 - Österle, Werner T1 - Characterisation of silica nanoparticles prior to in vitro studies: from primary particles to agglomerates N2 - The size, surface charge and agglomeration state of nanoparticles under physiological conditions are fundamental parameters to be determined prior to their application in toxicological studies. Although silica-based materials are among the most promising candidates for biomedical applications, more systematic studies concerning the characterisation before performing toxicological studies are necessary. This interest is based on the necessity to elucidate the mechanisms affecting its toxicity. We present here TEM, SAXS and SMPS as a combination of methods allowing an accurate determination of single nanoparticle sizes. For the commercial material, Ludox TM50 single particle sizes around 30 nm were found in solution. DLS measurements of single particles are rather affected by polydispersity and particles concentration but this technique is useful to monitor their agglomeration state. Here, the influence of nanoparticle concentration, ionic strength (IS), pH and bath sonication on the agglomeration behaviour of silica particles in solution has been systematically investigated. Moreover, the colloidal stability of silica particles in the presence of BSA has been investigated showing a correlation between silica and protein concentrations and the formation of agglomerates. Finally, the colloidal stability of silica particles in standard cell culture medium has been tested, concluding the necessity of surface modification in order to preserve silica as primary particles in the presence of serum. The results presented here have major implications on toxicity investigations because silica agglomeration will change the probability and uptake mechanisms and thereby may affect toxicity. KW - Silica KW - Toxicology KW - Agglomeration KW - BSA KW - Nanoparticles KW - Characterisation PY - 2011 DO - https://doi.org/10.1007/s11051-010-9910-9 SN - 1388-0764 SN - 1572-896X VL - 13 IS - 4 SP - 1593 EP - 1604 PB - Springer AN - OPUS4-21179 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Österle, Werner A1 - Bresch, Harald A1 - Dörfel, Ilona A1 - Fink, C. A1 - Giese, A. A1 - Prietzel, Claudia A1 - Seeger, Stefan A1 - Walter, J. T1 - Examination of airborne brake dust T2 - JEF 2010 - 6th European conference on braking CY - Lille, France DA - 2010-11-24 KW - Brake dust KW - Nanoparticles KW - Size-distribution PY - 2010 SP - 1 EP - 6(?) AN - OPUS4-22655 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wilke, Olaf A1 - Seeger, Stefan A1 - Bresch, Harald A1 - Brödner, Doris A1 - Juritsch, Elevtheria A1 - Jann, Oliver T1 - Sampling and characterisation of ultra fine particles released from laser printers T2 - Indoor Air 2008, August 17-22, 2008 CY - Copenhagen, Denmark DA - 2008-08-17 KW - Aerosol KW - Ultra fine particle KW - Laser printer KW - Cyclosiloxanes PY - 2008 IS - Paper ID: 239 SP - 1 AN - OPUS4-17865 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Österle, Werner A1 - Bresch, Harald A1 - Dörfel, Ilona A1 - Prietzel, Claudia A1 - Seeger, Stefan A1 - Fink, C. A1 - Giese, A. A1 - Walter, J. T1 - Surface film formation and dust generation during brake performance tests T2 - Braking 2009 CY - York, UK DA - 2009-06-09 KW - Bremse KW - Dritter Körper KW - Verschleiß KW - Reibung KW - Nanocharakterisierung KW - Aerosol PY - 2009 SN - 978-1-84334-559-6 IS - C672/028/09 SP - 29 EP - 38 PB - Woodhead Publishing Ltd AN - OPUS4-19574 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Size determination of non crystalline Silica particles with different methods T2 - International Aerosol Conference 2010 CY - Helsinki, Finland DA - 2010-08-29 PY - 2010 AN - OPUS4-21927 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Size selected nanoparticle quantifciation of deposited aerosol by GIXRF T2 - European Aerosol Conference 2011 CY - Manchester, England DA - 2011-09-04 PY - 2011 AN - OPUS4-24409 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Bresch, Harald A1 - Dörfel, Ilona A1 - Steinborn, Gabriele A1 - Krietsch, Arne A1 - Langner, Jeanette A1 - Schmidt, Martin A1 - Österle, Werner A1 - Seeger, Stefan T1 - Physical-chemical characterization of NM105(P25) N2 - NM 105, Ti02 (P25) could not be ignited as dust layer and dispersed in air as dust/air-mixture as well. This dust is not dust explosible and the burning behaviour corresponds to Burning Class 1 (no Ignition). The results have shown that the tested sample is thus not combustible at all, because it is already oxidized completely. KW - OECD KW - WPMN KW - TiO2 KW - NM105 KW - P25 KW - Sponsorship programme PY - 2012 SP - 1 EP - 18 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-27322 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Technical problems in aerosol generation and monitoring the size distribution for in vito and air-liquid-interface in vito tests T2 - Expert consultation meeting of the OECD-WPMN streering group 7 on alternative test methods in nanotoxicology CY - Paris, France DA - 2012-03-27 PY - 2012 AN - OPUS4-27461 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Production and characterization of nanoscaled aerosols T2 - JRC-Enlargement Workshop on the applications of nanobiotechnologies CY - Ispra, Italy DA - 2012-12-04 PY - 2012 AN - OPUS4-27462 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Qualification of quantitative grazing incidence X-ray fluorescence for the analysis of nano-particular surface contamination T2 - European Conference on X-Ray Spectrometry CY - Vienna, Austria DA - 2012-06-18 PY - 2012 AN - OPUS4-27463 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Bresch, Harald A1 - Meyer-Plath, Asmus A1 - Burgdorf, T. A1 - Packroff, R. A1 - Apel, P. A1 - Adolf, P. A1 - Jesse, A. A1 - Leuschner, C. A1 - Bosse, H. A1 - Dubbert, W. A1 - Epp, A. A1 - Gebel, T. A1 - Götz, M. A1 - Herzberg, F. A1 - Hornbogen, T. A1 - Kersten, N. A1 - Kneuer, C. A1 - Kujath, P. A1 - Pipke, R. A1 - Plitzko, s. A1 - Schlesier, K. A1 - Schröder, F. A1 - Schwirn, K. A1 - Sommer, Y. A1 - Tentschert, J. A1 - Völker, D. A1 - Wolf, T. T1 - 1. Bilanz zur gemeinsamen Forschungsstrategie der Ressortforschungseinrichtungen des Bundes 'Nanotechnologie - Gesundheits- und Umweltrisiken von Nanomaterialien' (2007 - 2011) KW - Nanotechnologie KW - Nanopartikel KW - Nanomaterial KW - Bundesoberbehörden KW - Forschungsstrategie PY - 2013 SP - 1 EP - 124 CY - Berlin AN - OPUS4-28538 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Critical needs and stakeholder networks for engineered particles in air N2 - In the frame of CCQM a new Task Group for particle characterization is being formed. This presentation is a gap analysis and stakeholder mapping for particles in air, from engineered to natural materials. The analysis was requested for the following points: (1) critical literature on stakeholder needs and relevant metrology (2) existing reference materials and relevant interlaboratory comparisons (3) relevant metrology projects (4) critical stakeholders and stakeholder networks and stakeholder surveys T2 - CCQM IAWG/SAWG TG Particle Metrology CY - Online meeting DA - 09.07.2024 KW - CCQM KW - Particle KW - Nano KW - Characterization KW - Aerosol PY - 2024 AN - OPUS4-62067 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Anwendungen von maschinellem Lernen und KI an der BAM N2 - Im Austausch mit den anderen Bundesoberbehörden wurden die KI-Ansätze der verschiedenen Bundesoberbehörden zu spezifischen Themen der Nanowissenschaften präsentiert. Der Vortrag der BAM fokusiert sich auf die Themen "Self driving lab", semantische Segmentierung und Auswertung von elektronenmikroskopischen Bildern sowie die Generierung von ausführbaren Machineninstruktionen aus natürlicher Sprache. Abschließend wird der neue BAM DataStore vorgestellt. T2 - Nano-Behördenklausur 2024 CY - Berlin, Germany DA - 03.07.02024 KW - Nano KW - Bundesoberbehörden KW - Künstliche Intelligenz KW - Neuronale Netzwerke KW - Elektronisches Laborbuch PY - 2024 AN - OPUS4-61819 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Schmidt, Alexandra A1 - Bresch, Harald A1 - Kämpf, K. A1 - Bachmann, V. A1 - Peters, T. A1 - Kuhlbusch, T. T1 - Development of a specific OECD Test Guideline on Particle Size and Particle Size Distribution of Nanomaterials N2 - In this research project, a new OECD Test Guideline (TG) for the determination of “Particle Size and Particle Size Distributions of Nanomaterials” was developed as the existing OECD TG 110 is considered to be outdated in terms of applicable size range (not covering sizes <200 nm) and methods. By its scope with an applicable size range from 1 to 1000 nm the new Test Guideline (TG PSD) covers the whole nanoscale. The TG PSD is applicable for particulate and fibrous nanomaterials. The prescribed, pairwise measurement of fibre diameter and length in the TG PSD allows for the first time to differen-tiate fibres with regard to their size-dependent hazard properties. Measurement instructions for each included method were validated within two separated interlaboratory comparisons, as a distinction between near spherical particles and fibres when applying the methods has to be made. Besides information on content and structure of the TG PSD, this final report outlines essential steps, considerations and organisational aspects during the development of the TG. Insights into the selec-tion, preparation and prevalidation of test materials used in the interlaboratory comparison are given. Finally, main results of the interlaboratory comparisons and their impacts on the TG PSD are pre-sented. N2 - Im Rahmen des Forschungsprojekts wurde eine neue OECD-Prüfrichtlinie (TG) für die Bestimmung von Partikelgrößen und Partikelgrößenverteilungen von Nanomaterialien entwickelt, da die existie-rende OECD TG 110 zur Bestimmung von Partikelgrößen in Bezug auf den anwendbaren Größenbe-reich und die gegebenen Methoden veraltet ist bzw. den Nanometerbereich < 200 nm nicht abdeckt. Mit ihrem Anwendungsbereich von 1 bis 1000 nm deckt die neue Prüfrichtlinie (TG PSD) die gesamte Nanoskala ab. Die TG PSD ist für partikel- und faserförmige Nanomaterialien anwendbar. Durch die, in der TG PSD vorgeschriebene, paarweise Messung von Faserdurchmesser und -länge ermöglicht diese TG zum ersten Mal Fasern hinsichtlich ihrer größenabhängigen Gefahrstoffeigenschaften zu unter-scheiden. Die Messanweisungen aller enthaltenen Methoden wurden im Rahmen von zwei getrennten Ringversuchen validiert, da bei der Anwendung der Methoden eine Unterscheidung zwischen Parti-keln und Fasern gemacht werden muss. Neben Angaben zum Inhalt und Struktur der TG PSD, befasst sich der vorliegende Abschlussbericht mit den wesentlichen Schritten, Überlegungen und organisatorischen Aspekten bei der Entwicklung der Prüfrichtlinie. Darüber hinaus werden Einblicke in die Auswahl, Vorbereitung und Prävalidierung der im Ringversuch verwendeten Testmaterialien gegeben. Schließlich werden die wichtigsten Ergeb-nisse aus den Ringversuchen und ihre Auswirkungen auf die TG PSD vorgestellt. KW - Nano KW - OECD KW - Particle size distribution KW - Testguideline KW - Nanoparticle PY - 2021 VL - 2021 SP - 1 EP - 47 PB - German Environment Agency CY - Dessau AN - OPUS4-54021 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Bresch, Harald A1 - Schmidt, Alexandra A1 - Kämpf, K. A1 - Bachmann, V. A1 - Peters, T. A1 - Kuhlbusch, T. T1 - Draft OECD Test Guideline for the Testing of Chemicals - Particle Size and Particle Size Distribution of Nanomaterials N2 - Final Draft of the OECD Test Guideline for Particle Size and Particle Size Distribution of Nanomaterials. The OECD Working Party on Manufactured Nanomaterials (WPMN) has actively worked towards understanding possible safety issues for manufactured nanomaterials and has contributed significantly to resolving these by developing Test Guidelines, Guidance Documents, Test Reports and other publications with the aim of a safe use of manufactured nanomaterials. The OECD website (www.oecd.org/science/nanosafety) and the referenced publications contain more background information. Among others, the OECD Test Guideline “Particle Size Distribution/Fibre Length and Diameter Distributions” (TG 110, adopted in 1981) was identified to require an update to address the specific needs of manufactured nanomaterials as the TG 110 is currently only valid for particles and fibres with sizes above 250 nm. The WPMN prioritised to either update TG 110 to be applicable also to particles at the nanoscale or draft a new nanomaterial specific Test Guideline (TG). Eventually, it was decided to develop a new TG for particle size and particle size distribution measurements of nanomaterials covering the size range from 1 nm to 1000 nm for further justification. This TG overlaps with TG 110 in the size range from 250 nm to 1000 nm. When measuring particulate or fibrous materials, the appropriate TG should be selected depending on the size range of particles tested. In line with TG 110, the new TG for nanomaterials includes separate parts for particles and fibres. For the part of this TG which addresses particles, several methods applicable to nanomaterials were reviewed and included to take into account developments since 1981 when the TG110 was adopted. This TG includes the following methods: Atomic Force Microscopy (AFM), Centrifugal Liquid Sedimentation (CLS)/Analytical Ultracentrifugation (AUC), Dynamic Light Scattering (DLS), Differential Mobility Analysis System (DMAS), (Nano)Particle Tracking Analysis (PTA/NTA), Small Angle X-Ray Scattering (SAXS), Scanning Electron Microscopy (SEM), and Transmission Electron Microscopy (TEM). For measuring the diameter and length of fibres, analysing images captured with electron microscopy is currently the only method available. This TG includes Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM). To test the validity of this TG, an ILC was performed. Test materials were chosen to reflect a broad 68 range of nanomaterial classes, e.g. metals, metal oxides, polymers and carbon materials. Where possible, well-characterised test materials were used. Additionally, the test materials were chosen, so that they reflect a broad range of sizes representing the size range 1 nm to 1000 nm and finally, for fibres only, aspect ratios from length/diameter of 3 to > 50. KW - Nano KW - OECD KW - Test guideline KW - Nanomaterial KW - Nanoparticle PY - 2021 UR - https://www.oecd.org/chemicalsafety/testing/draft-test-guideline-particle-size-distribution-nanomaterials.pdf SP - 1 PB - Organisation for Economic Co-operation and Development CY - Paris AN - OPUS4-53828 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Bresch, Harald A1 - Schmidt, Alexandra A1 - Kämpf, K. A1 - Bachmann, V. A1 - Peters, T. A1 - Kuhlbusch, T. T1 - Test Guideline No. 125 - Nanomaterial Particle Size and Size Distribution of Nanomaterials N2 - The OECD Working Party on Manufactured Nanomaterials (WPMN) has actively worked towards understanding possible safety issues for manufactured nanomaterials and has contributed significantly to resolving these by developing Test Guidelines, Guidance Documents, Test Reports and other publications with the aim of a safe use of manufactured nanomaterials. To address the specific needs of manufactured nanomaterials, the OECD Test Guideline No. 110 “Particle Size Distribution/Fibre Length and Diameter Distributions” was identified as one of the test guidelines (TGs) to require an update. The current TG 110 (adopted in 1981) is only valid for particles and fibres with sizes above 250 nm. The WPMN prioritised to either update TG 110 to be applicable also to particles at the nanoscale or draft a new nanomaterial specific (TG). Eventually, it was decided to develop a new TG that covers the size range from 1 nm to 1000 nm, intended for particle size and particle size distribution measurements of nanomaterials. Paragraph 11 provides further justification on the need for such measurements for nanomaterials. This TG overlaps with TG 110 in the size range from 250 nm to 1000 nm. When measuring particulate or fibrous materials, the appropriate TG should be selected depending on the size range of particles tested. In line with TG 110, the new TG for nanomaterials includes separate parts for particles and fibres. For the part of this TG which addresses particles, several methods applicable to nanomaterials were reviewed and included to take into account developments since 1981 when the TG 110 was adopted. This TG includes the following methods: Atomic Force Microscopy (AFM), Centrifugal Liquid Sedimentation (CLS)/Analytical Ultracentrifugation (AUC), Dynamic Light Scattering (DLS), Differential Mobility Analysis System (DMAS), (Nano)Particle Tracking Analysis (PTA/NTA), Small Angle X-Ray Scattering (SAXS), Scanning Electron Microscopy (SEM), and Transmission Electron Microscopy (TEM). The method Single Particle Inductively Coupled Plasma Mass Spectrometry (sp-ICP-MS) could not be sufficiently validated within the interlaboratory comparison (ILC) carried out for the different methods in this TG (see also paragraph 6 for further details on the ILC). Applicability of sp-ICP-MS is strongly limited to nanomaterials with high mass values in combination with a sufficiently high particle size. However, the general method ICP-MS is widely used and the sp-mode for the size measurement of specific nanomaterials was successfully performed in ILCs elsewhere. The method is therefore included in the Appendix Part C of this TG, which further details the limitations of sp-ICP-MS. For measuring the diameter and length of fibres, analysing images captured with electron microscopy is currently the only method available. This TG includes Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM). To test the validity of this TG, an ILC was performed. Test materials were chosen to reflect a broad range of nanomaterial classes, e.g. metals, metal oxides, polymers and carbon materials. Where possible, well-characterised test materials were used. Additionally, the test materials were chosen to reflect a broad range of sizes representing the size range 1 nm to 1000 nm. Specifically for fibres, a broad range of aspect ratios was included (length/diameter of 3 to > 50). Some of the test materials used are commercially available and further references are given in the validation report of the ILC. Sample preparation for physical chemical characterisation is critical for all listed methods. Due to the differences between individual nanomaterials and due to the wide range of individual material properties it is impossible to have a generic protocol to obtain the best possible sample preparation for every nanomaterial. Therefore, a generic protocol on sample preparation is not part of this TG. Information on sample preparation is given in the paragraphs 25-29, 33, 34 and 39 for particles and in paragraphs 159) for fibres. Further information on sample preparation of nanomaterials for physical chemical characterisation can be found in the OECD Guidance on Sample Preparation and Dosimetry for the Safety Testing of Manufactured Nanomaterials and elsewhere. KW - Nano KW - Nanomaterial KW - Nanoparticle KW - OECD KW - Test guideline PY - 2022 DO - https://doi.org/10.1787/20745753 SP - 1 EP - 72 PB - Organisation for Economic Co-operation and Development CY - Paris AN - OPUS4-55191 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Quantitative und qualitative Analyse von nanoskaligen Aerosolemissionen aus Industrieprodukten T2 - DPG-Frühjahrstagung 2008 CY - Darmstadt, Germany DA - 2008-03-10 PY - 2008 AN - OPUS4-16736 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Barthel, Mathias A1 - Pedan, Vasilisa A1 - Hahn, Oliver A1 - Rothhardt, Monika A1 - Bresch, Harald A1 - Jann, Oliver A1 - Seeger, Stefan T1 - XRF-Analysis of fine and ultrafine particles emitted from laser printing devices N2 - In this work, the elemental composition of fine and ultrafine particles emitted by ten different laser printing devices (LPD) is examined. The particle number concentration time series was measured as well as the particle size distributions. In parallel, emitted particles were size-selectively sampled with a cascade impactor and subsequently analyzed by the means of XRF. In order to identify potential sources for the aerosol's elemental composition, materials involved in the printing process such as toner, paper, and structural components of the printer were also analyzed. While the majority of particle emissions from laser printers are known to consist of recondensated semi volatile organic compounds, elemental analysis identifies Si, S, Cl, Ca, Ti, Cr, and Fe as well as traces of Ni and Zn in different size fractions of the aerosols. These elements can mainly be assigned to contributions from toner and paper. The detection of elements that are likely to be present in inorganic compounds is in good agreement with the measurement of nonvolatile particles. Quantitative measurements of solid particles at 400 °C resulted in residues of 1.6 × 109 and 1.5 × 1010 particles per print job, representing fractions of 0.2% and 1.9% of the total number of emitted particles at room temperature. In combination with the XRF results it is concluded that solid inorganic particles contribute to LPD emissions in measurable quantities. Furthermore, for the first time Br was detected in significant concentrations in the aerosol emitted from two LPD. The analysis of several possible sources identified the plastic housings of the fuser units as main sources due to substantial Br concentrations related to brominated flame retardants. KW - Particulate emissions KW - UFP KW - FP KW - Laser printers KW - XRF PY - 2011 DO - https://doi.org/10.1021/es201590q SN - 0013-936X SN - 1520-5851 VL - 45 IS - 18 SP - 7819 EP - 7825 PB - ACS Publ. CY - Washington, DC AN - OPUS4-24393 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wienold, Julia A1 - Traub, Heike A1 - Bresch, Harald A1 - Seeger, Stefan A1 - Recknagel, Sebastian A1 - Kipphardt, Heinrich T1 - Effort on calibration of infrared spark ablation of copper with synthetic copper standards N2 - Two types of copper samples, compact certified copper reference materials and calibration samples prepared from liquid doped, pressed copper powders, were studied in terms of accuracy of obtained calibration functions originating from infrared spark ablation. Additionally, corresponding particle size distributions of the aerosols from infrared spark ablation were recorded. It is shown that the differences in quantification results, originating from the two sets of calibration functions, could not mainly be ascribed to different particle size distributions of the two copper sample types. Possible other causes, as different ablation rates, parts of melting and differences of the chemical constitutions of the two sample types were explored. KW - Calibration KW - Spark ablation KW - Synthetic standard KW - Particle size distribution KW - Fractionation KW - Laser ablation KW - ICP-MS PY - 2011 DO - https://doi.org/10.1016/j.sab.2011.04.005 SN - 0584-8547 SN - 0038-6987 VL - 66 IS - 6 SP - 432 EP - 438 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-24065 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Recknagel, Sebastian A1 - Bresch, Harald A1 - Kipphardt, Heinrich A1 - Resch-Genger, Ute A1 - Koch, Matthias A1 - Rosner, M. T1 - Trends in selected fields of reference material production N2 - For more than 110 years, BAM has been producing reference materials for a wide range of application fields. With the development of new analytical methods and new applications as well as continuously emerging more stringent requirements of laboratory accreditation with regard to quality control and metrological traceability, the demand and requirements for reference materials are increasing. This trend article gives an overview of general developments in the field of reference materials as well as developments in selected fields of application in which BAM is active. This includes inorganic and metal analysis, gas analysis, food and consumer products, and geological samples. In addition to these more traditional fields of application, developments in the areas of optical spectroscopy, particulary fluorescence methods, and nanomaterials are considered. T2 - 150 years BAM: Science with impact CY - Berlin, Germany DA - 01.01.2021 KW - Reference material KW - ISO REMCO KW - Gas analysis KW - Food KW - Nanomaterials KW - Fluorescence PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-548407 DO - https://doi.org/10.1007/s00216-022-03996-7 SN - 1618-2642 SN - 1618-2650 VL - 414 IS - Topical collection: Analytical methods and applications in the materials and life sciences SP - 4281 EP - 4289 PB - Springer CY - Berlin AN - OPUS4-54840 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - Nanoparticle Characterisation - The long way to standardisation N2 - Diese Präsentation gibt einen Überblick über die Entwicklung der Nanopartikelforschung von ca. 2005 bis heute. Beginnend mit den Besonderheiten von Nanopartikeln und der Aufnahme in den menschlichen Körper über Messmethoden bis hin zur Entwicklung einer Prüfrichtlinie im Rahmen der OECD und einem Ausblick über die absehbaren digitalen Entwicklungen. T2 - Abteilungsseminar der Abteilung 4 CY - Berlin, Germany DA - 27.02.2025 KW - Nanomaterials KW - Nano KW - OECD KW - Standardisierung KW - Advanced Materials PY - 2025 AN - OPUS4-64977 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald T1 - The digital product passport N2 - This presentation contains information for industry and the scientific communitiy about the new digital product passport and the demands from the EU. Furthermore a short overview is given about the different supporting activities which are currently under developement by BAM. T2 - 3. Netzwerktag Cluster Nanotechnologie CY - Würzburg, Germany DA - 02.07.2025 KW - DPP KW - ESPR KW - Product Passport KW - Ökodesignrichtlinie KW - DMP PY - 2025 AN - OPUS4-64964 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Bresch, Harald A1 - Lexow, Jürgen A1 - Sturm, Heinz A1 - Packroff, R. A1 - Völker, D. A1 - Mutz, D. A1 - Bosse, H. A1 - Gebel, T. A1 - Pipke, R. A1 - Marx, R. A1 - Plitzko, S. A1 - Niesmann, K. A1 - Meyer-Plath, A. A1 - Burgdorf, T. A1 - Engel, N. A1 - Epp, A. A1 - Haase, A. A1 - Herzberg, F. A1 - Laux, P. A1 - Oberemm, A. A1 - Sommer, Y. A1 - Tentschert, J. A1 - Ulm, G. A1 - Schwirn, K. A1 - Liesegang, C. T1 - Nanomaterialien und andere innovative Werkstoffe: anwendungssicher und umweltverträglich T1 - Nanomaterials and other advanced materials: application safety and environmental compatibility N2 - Mit einer langfristigen Forschungsstrategie begleiten die für die Sicherheit von Mensch und Umwelt zuständigen Bundesoberbehörden (Umweltbundesamt, Bundesinstitut für Risikobe-wertung, Bundesanstalt für Arbeitsschutz und Arbeitsmedizin, Bundesanstalt für Materialfor-schung und -prüfung und Physikalisch-Technische Bundesanstalt) die rasch voranschreiten-de Entwicklung neuer Materialien unter den Gesichtspunkten des Arbeits-, Verbraucher- und Umweltschutzes. Die Strategie steht daher in enger Verbindung zu den öffentlichen Förder-programmen für Nanomaterialien und andere innovative Werkstoffe, z. B. des BMBF („Vom Material zur Innovation“) und der EU („Horizon 2020“). Die Forschungsstrategie baut auf den bisherigen Ergebnissen der 2008 begonnenen und 2013 erstmals bilanzierten gemeinsamen Forschungsstrategie der Bundesoberbehörden „Nanotechnologie - Gesundheits- und Umweltrisiken von Nanomaterialien"1 auf und erweitert den Blickwinkel auch auf andere Materialinnovationen, bei denen vergleichbare Risiken für Mensch und Umwelt bestehen oder abgeklärt werden müssen. Darüber hinaus greift sie die Idee „anwendungssichere chemische Produkte“2 aus der Initiative „Neue Qualität der Arbeit“ (INQA) des Bundesministeriums für Arbeit und Soziales (BMAS) und das Konzept der nach-haltigen Chemie3 auf, das vom Bundesministerium für Umwelt, Naturschutz, Bau und Reak-torsicherheit (BMUB) unterstützt wird. Durch eine anwendungssichere und umweltverträgli-che Gestaltung innovativer Materialien und ihrer Folgeprodukte sollen nicht akzeptable Risi-ken für Mensch und Umwelt von Anfang an weitgehend ausgeschlossen werden. Dies kann erreicht werden durch 1. die Verwendung sicherer Materialien ohne Gefahreneigenschaften für Mensch und Umwelt (direkte Anwendungssicherheit) oder 2. eine Produktgestaltung, die über den gesamten Lebenszyklus emissionsarm und umweltverträglich ist (integrierte Anwendungssicherheit) oder 3. eine Unterstützung des Anwenders (product stewardship) durch den Hersteller bei technischen, organisatorischen und persönlichen Schutzmaßnahmen zur sicheren Verwendung und Entsorgung des Produktes (unterstützte Anwendungssicherheit). Die Fortschreibung der Forschungsstrategie soll als Bestandteil des Nanoaktionsplans 2020 der Bundesregierung Beiträge der Ressortforschung zu folgenden Schwerpunkten leisten: • Charakterisierung und Bewertung der Risiken von Materialinnovationen • Unterstützung von Forschungseinrichtungen und Unternehmen • Fortschreiben von Rechtsvorschriften und Praxisempfehlungen 1 http://www.baua.de/nn_47716/de/Themen-von-A-Z/Gefahrstoffe/Nanotechnologie/pdf/Forschungsstrategie.pdf 2 http://www.baua.de/de/Themen-von-A-Z/Gefahrstoffe/Nachhaltige-Chemie/Nachhaltige-Chemie.html 3 http://www.umweltbundesamt.de/themen/chemikalien/chemikalien-management/nachhaltige-chemie 2 • Gesellschaftliche Akzeptanz Die Forschungsstrategie soll mit Projekten und anderen forschungsnahen Aktivitäten umge-setzt werden. Dies umfasst die eigene Forschung der Häuser, die extramurale Ausschrei-bung und Vergabe von Forschungsdienstleistungen sowie die Beteiligung an vorwiegend öffentlich geförderten Drittmittelprojekten. Hinzu kommen Aktivitäten im Rahmen der Politik-beratung und der hoheitlichen Aufgaben. Mit inter- und transdisziplinären Ansätzen soll die Risiko- und Sicherheitsforschung enger mit der Innovationsforschung und Materialentwick-lung verknüpft werden. Die Forschungsstrategie ist aufgrund der raschen Entwicklungen auf diesem Gebiet für den Zeitraum bis 2020 angelegt. Die Forschungsziele adressieren die in diesem Zeitraum voraussichtlich umsetzbaren Forschungsansätze. Die Forschungsstrategie wird durch einen Arbeitskreis begleitet und spätestens mit Ablauf des Nanoaktionsplans 2020 evaluiert und angepasst. KW - Forschungsstrategie KW - Bundesoberbehörden KW - Nanomaterialien KW - Innovative Werkstoffe KW - Nano PY - 2016 UR - https://www.bam.de/_SharedDocs/DE/Downloads/nano-forschungsstrategie-2016.pdf?__blob=publicationFile&v=3 UR - http://www.baua.de/de/Themen-von-A-Z/Gefahrstoffe/Nanotechnologie/pdf/Fortschreibung-Forschungsstrategie.pdf?__blob=publicationFile&v=3 UR - http://www.bmub.bund.de/fileadmin/Daten_BMU/Download_PDF/Nanotechnologie/forschungsstrategie_bundesoberbehoerden_de_bf.pdf SP - 1 EP - 28 PB - UBA/BfR/BAuA/BAM/PTB CY - Berlin AN - OPUS4-37526 LA - mul AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bresch, Harald A1 - Rühle, Bastian T1 - Stand der Aktivitäten zur gemeinsamen Forschungsstrategie N2 - Die gemeinsame Forschungsstrategie der Bundesoberbehörden zur Nanotechnologie wurde 2016 veröffentlicht. Die darin enthaltenen Aufgaben wurden von den Bundesoberbehörden vielfältig bearbeitet. Diese Präsentation gibt einen Überblick über die Projekte, die von der BAM bis 2019 bearbeitet wurden/werden und sich in den Rahmen der Forschungsstrategie einordnen. T2 - Workshop zur gemeinsamen Forschungsstrategie der Bundesoberbehörden „Nanomaterialien und andere innovative Werkstoffe: anwendungssicher und umweltverträglich“ CY - Berlin, Germany DA - 02.09.2019 KW - Nano KW - Bundesoberbehörden KW - Forschungsstrategie KW - Nanomaterialien KW - Nanotechnologie PY - 2019 AN - OPUS4-49586 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -