TY - JOUR A1 - Christensen, J. B. A1 - Jørgensen, A. A. A1 - Vandborg, M. H. A1 - Thomas, P. J. A1 - Lu, Xin A1 - Failleau, G. A1 - Eisermann, R. A1 - Grüner-Nielsen, L. A1 - Balslev-Harder, D. A1 - Lassen, M. A1 - Krenek, S. T1 - Fiber-artefact methodology and calibration framework for Brillouin-based fiber sensing N2 - We propose, and demonstrate, the use of a fiber-optical measurement artefact as a metrological tool for traceable distance calibration of distributed optical fiber sensors. The constructed fiber artefact consists of a lead-in fiber coupled to a fiber loop using a 3-dB coupler and is used to calibrate both a home-build Brillouin-OTDR setup and a custom version of a commercial Brillouin-OTDR interrogator build for distributed temperature sensing. For both interrogators, we demonstrate distance calibrations with 1-meter uncertainty (k=1) in the offset length and 0.1 % (1 m/km) uncertainty (k = 1) in the distance scale factor. In addition, it is shown that the fiber artefact can be used to assess undesired distance-dependent measurement biases. KW - Distributed temperature sensing KW - Metrology KW - Distributed optical fiber sensing KW - Brillouin optical time-domain reflectrometry PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-618853 DO - https://doi.org/10.1364/OE.544659 SN - 1094-4087 VL - 32 IS - 26 SP - 45483 EP - 45493 PB - Optica Publishing Group AN - OPUS4-61885 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -