TY - CONF A1 - Nadejde, C. A1 - Neamtu, Mariana A1 - Hodoroaba, Vasile-Dan A1 - Schneider, Rudolf A1 - Paul, Andrea A1 - Ababei, G. A1 - Panne, Ulrich T1 - Green Fenton-like catalysts for the removal of water pollutants N2 - Two types of surface modified magnetite (Fe3O4) nanoparticles, coated with either tannic acid (TA) or dissolved natural organic matter (NOM), were evaluated as magnetic heterogeneous catalysts. Simple and efficient procedures for the synthesis of the magnetic catalysts were employed, their properties being fully assessed by various characterization techniques. The catalytic activity in heterogeneous oxidation of aqueous solutions containing Bisphenol A (BPA) over the catalysts was comparatively studied. The optimum experimental parameters were: 1g/L of catalysts, 10 mM H2O2, under UV irradiation. The highest mineralization rates were observed for Fe3O4-TA catalyst. More than 80% of BPA were removed after 30 minutes of reaction time under the specified experimental conditions. The results showed that the obtained catalysts are suitable candidates for the removal of pollutants in wastewaters by means of heterogeneous reaction T2 - TechConnect World Innovation Conference Nanotech 2015 CY - Washington, DC, Maryland, USA DA - 14.06.2015 KW - Nanocatalysts KW - Characterization KW - Fenton oxidation KW - Wastewater KW - Bisphenol A degradation PY - 2015 SN - 978-1- 4987-4733-2 SN - 978-1-4987-4728-8 VL - 2 SP - 87 EP - 90 PB - CRC Press, Taylor&Francis Group AN - OPUS4-40074 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nadejde, C. A1 - Neamtu, Mariana A1 - Hodoroaba, Vasile-Dan A1 - Schneider, Rudolf A1 - Ababei, G. A1 - Panne, Ulrich T1 - Characterization and application of Green Fenton-like catalysts for the removal of water pollutants N2 - Three types of magnetite-chitosan/iron oxalate/iron citrate nanoparticles (NP) were evaluated as magnetic heterogeneous catalysts for water treatment. T2 - PTIM 2015, 1st International Caparica Conference on Pollutant Toxic Ions and Molecules CY - Caparica, Portugal DA - 02.112015 KW - Bisphenol A degradation KW - Nanocatalysts KW - Characterization KW - Fenton oxidation KW - Wastewater PY - 2015 SN - 978-989-99361-6-4 SP - 186 EP - 187 PB - Proteomass AN - OPUS4-40082 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Eilers, M. A1 - Alte-Teigeler, R. A1 - Borchers, R. A1 - Gallai, G. A1 - Habiger, D. A1 - Recknagel, Christoph A1 - Karczewski, B. A1 - Koll, J. A1 - Lorenz, S. A1 - Marossow, H. A1 - Schneider, Th. A1 - Seiffart, J. A1 - Stark, S. A1 - et al., T1 - Zusätzliche Technische Vertragsbedingungen und Richtlinien für Ingenieurbauten, Teil 6: Bauwerksausstattung, Abschnitt 7: Fahrbahnübergänge N2 - Die Zusätzlichen Technischen Vertragsbedingungen und Richtlinien für Ingenieurbauten (ZTV-ING) wurden zuletzt mit ARS Nr. 23/2021 vom 20. 10. 2021 mit dem Stand 2021/10 fortgeschrieben. Die jetzige Fortschreibung beinhaltet eine Gliederungsänderung des Regelwerks, um die für den Brückenbau relevanten Teile vorne gebündelt darstellen zu können. Eine Synopse hierzu ist der Anlage 4 zu entnehmen. „Wesentliche Änderungen in den ZTV-ING“ gegenüber der letzten Fassung sind der Anlage 3 zu entnehmen. In gleicher Weise sind die aktuellen „Hinweise zu den ZTV-ING — Stand 2022/01“ gemäß Anlage 2 einzubeziehen. Die Hinweise zu den entsprechenden Abschnitten der ZTV-ING sind bei der Projektbearbeitung und Ausschreibung zu beachten. Soweit die „Hinweise zu den ZTV-ING“ für die jeweilige Maßnahme zutreffend sind und vertragsrechtliche Bedeutung haben, sind entsprechende Textpassagen gesondert in die Vergabeunterlagen aufzunehmen bzw. zu vereinbaren. KW - Brückenbeläge KW - Asphaltbauweisen KW - Fahrbahnübergänge PY - 2022 SN - 978-3-86446-344-0 VL - 782/7 SP - 1 EP - 30 PB - FGSV Verlag GmbH CY - Köln AN - OPUS4-56219 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Büchner, T. A1 - Drescher, D. A1 - Merk, V. A1 - Traub, Heike A1 - Guttmann, P. A1 - Werner, St. A1 - Jakubowski, Norbert A1 - Schneider, G. A1 - Kneipp, J. T1 - Biomolecular environment, quantification, and intracellular interaction of multifunctional magnetic SERS nanoprobes N2 - Multifunctional composite nanoprobes consisting of iron oxide nanoparticles linked to silver and gold nanoparticles, Ag–Magnetite and Au–Magnetite, respectively, were introduced by endocytic uptake into cultured fibroblast cells. The cells containing the non-toxic nanoprobes were shown to be displaceable in an external magnetic field and can be manipulated in microfluidic channels. The distribution of the composite nanostructures that are contained in the endosomal system is discussed on the basis of surfaceenhanced Raman scattering (SERS) mapping, quantitative laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) micromapping, and cryo soft X-ray tomography (cryo soft-XRT). Cryo soft-XRT of intact, vitrified cells reveals that the composite nanoprobes form intra-endosomal aggregates. The nanoprobes provide SERS signals from the biomolecular composition of their surface in the endosomal environment. The SERS data indicate the high stability of the nanoprobes and of their plasmonic properties in the harsh environment of endosomes and lysosomes. The spectra point at the molecular composition at the surface of the Ag–Magnetite and Au–Magnetite nanostructures that is very similar to that of other Composite structures, but different from the composition of pure silver and gold SERS nanoprobes used for intracellular investigations. As shown by the LA-ICP-MS data, the uptake efficiency of the magnetite composites is approximately two to three times higher than that of the pure gold and silver nanoparticles. KW - Nanoparticles KW - SERS KW - Cell KW - LA-ICP-MS KW - X-ray tomography PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-371811 DO - https://doi.org/10.1039/c6an00890a SN - 0003-2654 VL - 141 IS - 17 SP - 5096 EP - 5106 PB - Royal Society of Chemistry CY - Cambridge, UK AN - OPUS4-37181 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Smekhova, A. A1 - Kuzmin, A. A1 - Siemensmeyer, K. A1 - Abrudan, R. A1 - Reinholz, Uwe A1 - de Oliveira Guilherme Buzanich, Ana A1 - Schneider, M. A1 - Laplanche, G. A1 - Yusenko, Kirill T1 - Inner relaxations in equiatomic single-phase high-entropy Cantoralloy N2 - The superior properties of high-entropy multi-functional materials are strongly connected with their atomic heterogeneity through many different local atomic interactions. The detailed element-specific studies on a local scale can provide insight into the primary arrangements of atoms in multicomponent systems and benefit to unravel the role of individual components in certain macroscopic properties of complex compounds. Herein, multi-edge X-ray absorption spectroscopy combined with reverse Monte Carlo simulations was used to explore a homogeneity of the local crystallographic ordering and specific structure relaxations of each constituent in the equiatomic single-phase facecentered cubic CrMnFeCoNi high-entropy alloy at room temperature. Within the considered fitting approach, all five elements of the alloy were found to be distributed at the nodes of the fcc lattice without any signatures of the additional phases at the atomic scale and exhibit very close statistically averaged interatomic distances (2.54 – 2.55 Å) with their nearest-neighbors. Enlarged structural displacements were found solely for Cr atoms. The macroscopic magnetic properties probed by conventional magnetometry demonstrate no opening of the hysteresis loops at 5 K and illustrate a complex character of the long-range magnetic order after field-assisted cooling in ± 5 T. The observed magnetic behavior is assigned to effects related to structural relaxations of Cr. Besides, the advantages and limitations of the reverse Monte Carlo approach to studies of multicomponent systems like high-entropy alloys are highlighted. KW - Magnetism KW - High-entropy alloys KW - Reverse Monte Carlo (RMC) KW - Element-specific spectroscopy KW - Extended X-ray absorption fine structure (EXAFS) KW - X-ray absorption near edge structure (XANES) PY - 2022 DO - https://doi.org/10.1016/j.jallcom.2022.165999 SN - 0925-8388 VL - 920 SP - 1 EP - 31 PB - Elsevier AN - OPUS4-55457 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carvalho, José Joao A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - Monitoring caffeine in human saliva using a newly developed ELISA N2 - Caffeine is a useful indicator to quickly assess liver function. High-throughput tests are needed for single-point caffeine measurements, with low cross-reactivity toward its major metabolite, paraxanthine. A newly developed ELISA was compared with an LC-MS/MS reference method, using 60 saliva samples from 10 individuals, before and after caffeine intake. Bland-Altman plot, Student t-test and F-test were used to compare the two methods. Proteins were precipitated using organic solvent and the caffeine recoveries compared with those obtained using sample microfiltration. The antibody, with a low cross-reactivity toward paraxanthine (0.08%), allows quantification of caffeine in saliva samples from 2.5 µg/L to 125 µg/L with high precision and the ELISA shows comparable results to those obtained by LC-MS/MS. A one-step protein precipitation using an organic solvent provides comparable results to a more costly and time-consuming microfiltration pre-treatment of samples. The new ELISA is a fit-for-purpose method to accurately and precisely determine caffeine in saliva samples. KW - Caffeine KW - Cytochrome P450 CYP1A2 KW - Enzyme-linked immunosorbent assay KW - LC-MS/MS KW - Liver function tests KW - Saliva PY - 2012 DO - https://doi.org/10.1080/00032719.2012.696226 SN - 0003-2719 SN - 1532-236X VL - 45 IS - 17 SP - 2549 EP - 2561 PB - Taylor & Francis CY - Philadelphia, Pa. AN - OPUS4-27267 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bahlmann, Arnold A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - Monitoring carbamazepine in surface and wastewaters by an immunoassay based on a monoclonal antibody N2 - The pharmaceutical compound carbamazepine (CBZ) is an emerging pollutant in the aquatic environment and may potentially be used as a wastewater marker. In this work, an enzyme-linked immunosorbent assay (ELISA) for the detection of carbamazepine in surface and sewage waters has been developed. The heterogeneous immunoassay is based on a commercially available monoclonal antibody and a novel enzyme conjugate (tracer) that links the hapten via a hydrophilic peptide (triglycine) spacer to horseradish peroxidase. The assay achieves a limit of detection of 24 ng/L and a quantitation range of 0.05-50 µg/L. The analytical performance and figure of merits were compared to liquid chromatography-tandem mass spectrometry after solid-phase extraction. For nine Berlin surface water samples and one wastewater sample, a close correlation of results was observed. A constant overestimation relative to the CBZ concentration of approximately 30% by ELISA is probably caused by the presence of 10,11-epoxy-CBZ and 2-hydroxy-CBZ in the samples. The ELISA displayed cross-reactivities for these compounds of 83% and 14%, respectively. In a first screening of 27 surface water samples, CBZ was detected in every sample with concentrations between 0.05 and 3.2 µg/L. Since no sample cleanup is required, the assay allowed for the determination of carbamazepine with high sensitivity at low costs and with much higher throughput than with conventional methods. KW - Carbamazepine KW - ELISA KW - Antibody KW - Immunoassay KW - Surface water KW - LC-MS/MS KW - Pharmaceuticals PY - 2009 DO - https://doi.org/10.1007/s00216-009-2958-7 SN - 1618-2642 SN - 1618-2650 VL - 395 IS - 6 SP - 1809 EP - 1820 PB - Springer CY - Berlin AN - OPUS4-20927 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carvalho, José Joao A1 - Walter, Astrid A1 - Baermann, Yvonne A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schenk, J.A. A1 - Schneider, Rudolf T1 - Non-invasive monitoring of immunization progress in mice via IgG from feces N2 - A non-invasive method to monitor the humoral immune response in mice after immunization is described. From fecal pellets of an individual mouse, a sufficient amount of active immunoglobulins or their fragments can be extracted to perform a regular examination of the status of the immune response by immunoassay. Hapten-specific antibodies from the feces of mice from three immunization trials showed very similar characteristics to those obtained from serum at a given date. Therefore, it can be suspected that some serum IgG enters the intestinal lumen and ends up in the feces, where they appear to be considerably stable. Hapten-specific IgAs were not found in the feces. Being able to analyze antibody titers in feces could be an interesting animal welfare refinement to standard practice that does not entail repeated blood sampling. KW - Immunization monitoring KW - IgG KW - Coproantibodies KW - Feces KW - Animal welfare KW - 3R concept PY - 2012 UR - http://iv.iiarjournals.org/content/26/1/63.full.pdf+html SN - 0258-851x VL - 26 IS - 1 SP - 63 EP - 70 PB - In vivo CY - Athens AN - OPUS4-25283 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Walter, Astrid A1 - Pfeifer, Dietmar A1 - Kraus, Werner A1 - Emmerling, Franziska A1 - Schneider, Rudolf A1 - Panne, Ulrich A1 - Weller, Michael G. T1 - Triacetone Triperoxide (TATP): Hapten design and development of antibodies N2 - Triacetone triperoxide (TATP), an improvised explosive, is a potential security threat because of its cost-efficient synthesis and the difficulty in detecting it. A highly selective antibody could provide the necessary specificity to the detection process. To obtain antibodies, a hapten made from acetone, hydrogen peroxide, and 7-oxooctanoic acid has been designed, synthesized, and confirmed by NMR that displays the utmost similarity to the analyte. The single-crystal X-ray structures of the solvated species TATP·methanol (1:1) and the TATP derivate were determined. In both compounds, the molecules exhibit D3 symmetry and adopt a twisted boat-chair conformation. The hapten was coupled to bovine serum albumin, and mice were immunized. An immune response against TATP was elicited, and selective antibodies were detected in the mouse serum, which should be very useful for the development of a TATP biosensor system. An ELISA with a limit of detection for TATP of 65 µg L-1 is shown. KW - TATP KW - Triacetone triperoxide KW - Explosive KW - Antibody KW - Hapten immunoassay KW - Structure PY - 2010 DO - https://doi.org/10.1021/la1018339 SN - 0743-7463 SN - 1520-5827 VL - 26 IS - 19 SP - 15418 EP - 15423 PB - American Chemical Society CY - Washington, DC AN - OPUS4-22469 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carvalho, José Joao A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - A highly sensitive caffeine immunoassay based on a monoclonal antibody KW - Caffeine KW - ELISA KW - Antibody KW - LC–MS–MS KW - Water KW - Wastewater marker PY - 2010 DO - https://doi.org/10.1007/s00216-010-3506-1 SN - 1618-2642 SN - 1618-2650 VL - 396 IS - 7 SP - 2617 EP - 2628 PB - Springer CY - Berlin AN - OPUS4-22651 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bahlmann, Arnold A1 - Carvalho, José Joao A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - Immunoassays as high-throughput tools: monitoring spatial and temporal variations of carbamazepine, caffeine and cetirizine in surface and wastewaters N2 - Carbamazepine (CBZ), caffeine and cetirizine were monitored by enzyme-linked immunosorbent assays (ELISAs) in surface and wastewaters from Berlin, Germany. This fast and cost-efficient method enabled to assess the spatial and temporal variation of these anthropogenic markers in a high-throughput screening. CBZ and cetirizine were detected by the same antibody, which selectively discriminates between both compounds depending on the pH value used in the incubation step. To our best knowledge, this is the first dual-analyte immunoassay working with a single antibody. The frequent sampling with 487 samples being processed allowed for the repeated detection of unusually high concentrations of CBZ and caffeine. ELISA results correlate well with the ones obtained by liquid chromatography tandem mass spectrometry (LC-MS/MS). Caffeine concentrations found in surface waters were elevated by combined sewer overflows after stormwater events. During the hay fever season, the concentrations of the antihistamine drug cetirizine increased in both surface and wastewaters. Caffeine was almost completely removed during wastewater treatment, while CBZ and cetirizine were found to be more persistent. The maximum concentrations of caffeine, CBZ and cetirizine found in influent wastewater by LC–MS/MS were 470, 5.0 and 0.49 µg L-1, while in effluent wastewater the concentrations were 0.22, 4.5 and 0.51 µg L-1, respectively. For surface waters, concentrations up to 3.3, 4.5 and 0.72 µg L-1 were found, respectively. KW - ELISA KW - Carbamazepine KW - Caffeine KW - Cetirizine KW - Environmental monitoring KW - Anthropogenic markers PY - 2012 DO - https://doi.org/10.1016/j.chemosphere.2012.05.020 SN - 0045-6535 SN - 0366-7111 VL - 89 IS - 11 SP - 1278 EP - 1286 PB - Elsevier Science CY - Kidlington, Oxford AN - OPUS4-26187 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weller, Michael G. A1 - Schneider, Rudolf A1 - Rurack, Knut T1 - Mit dem Testsystem zur Probe N2 - (Bio)chemische Sensoren ersetzen bei der Vor-Ort-Analytik die großen Messgeräte oder dienen dazu, Analyten im Verdachtsfall oder kontinuierlich zu überwachen. Das können pharmazeutische Stoffe im Abwasser sein, Aflatoxin in Milch oder Sprengstoff am Flughafen. Ein Überblick über Neuentwicklungen. KW - Biochemische Sensoren KW - Vor-Ort-Analytik KW - Schnelltests KW - Antikörper PY - 2021 DO - https://doi.org/10.1002/nadc.20214112170 VL - 69 IS - 10 SP - 71 EP - 74 PB - Wiley-VCH CY - Weinheim AN - OPUS4-54003 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nusser, K. A1 - Mosbauer, T. A1 - Schneider, G. J. A1 - Brandt, K. A1 - Weidemann, Gerd A1 - Goebbels, Jürgen A1 - Riesemeier, Heinrich A1 - Göritz, D. T1 - Silica dispersion in styrene butadiene rubber composites studied by synchrotron tomography N2 - By means of synchrotron X-ray computed tomography, model composites consisting of silica and styrene–butadiene rubber were studied with a very high spatial resolution. By our analysis technique we were able to determine the nano- and micro dispersion from the experimental results by our numerical analysis. These results are discussed with respect to crucial advantages of the generically 3-dimensional tomography technique as compared to 2-dimensional methods. Our quantitative analysis of the 3d images demonstrates that in the case of our model composites the filler dispersion is good, independent on the filler concentration. Our new 3-dimensional results evidence that considering only 2-d pictures may lead to ambiguities that can lead to wrong conclusions. KW - X-ray tomography KW - Silica KW - Styrene butadiene rubber KW - Dispersion PY - 2012 DO - https://doi.org/10.1016/j.jnoncrysol.2011.10.009 SN - 0022-3093 VL - 358 IS - 3 SP - 557 EP - 563 PB - North-Holland Publ. Co. CY - Amsterdam AN - OPUS4-26105 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bahlmann, Arnold A1 - Falkenhagen, Jana A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - Cetirizine as pH-dependent cross-reactant in a carbamazepine-specific immunoassay N2 - High performance liquid chromatography (HPLC) was hyphenated with a previously reported carbamazepine-specific enzyme-linked immunosorbent assay (ELISA) as a screening approach to water analysis in order to identify possible interferences from transformation products. Treated wastewater was analysed and three substances were recognized by the antibody besides carbamazepine: the metabolites 10,11-dihydro-10,11-epoxycarbamazepine and 2-hydroxycarbamazepine plus the structurally not obviously related antihistamine cetirizine. The molar cross-reactivity against cetirizine was found to be pH-dependent and assessed to be 400% at pH 4.5 and 22% at pH 10.5. Performing the ELISA at pH 10.5 greatly improved the accuracy when carbamazepine was determined in surface and wastewater samples. KW - Immunoassay KW - ELISA KW - Cetirizin KW - Carbamazepin KW - pH-Abhängigkeit KW - Kreuzreaktivität PY - 2011 DO - https://doi.org/10.1039/c0an00928h SN - 0003-2654 SN - 1364-5528 VL - 136 IS - 7 SP - 1357 EP - 1364 PB - Royal Society of Chemistry CY - Cambridge AN - OPUS4-23546 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Herbst, Tristan A1 - Beck, T. A1 - Schneider, S. A1 - Flassenberg, G. T1 - Nachhaltigkeitsanalyse für das Mauerwerksrecycling N2 - In Deutschland fällt mittelfristig eine nicht unerhebliche Menge an Mauerwerksbruch an. Im Sinne einer nachhaltigen Kreislaufwirtschaft sind diese Restmassen zukünftig einem möglichst hochwertigen Recycling zuzuführen. Im Rahmen des IGF-Forschungsvorhabens 17022 N der Forschungsvereinigung Porenbetonindustrie e.V., Berlin, wird im Gesamtkontext “SIM Stoffkreislauf im Mauerwerksbau“ die Nachhaltigkeit verschiedener Recyclingoptionen für Mauerwerksbruch unter Einbeziehung der Hauptwandbausteinarten Ziegel, Kalksandstein, Porenbeton und Leichtbeton sowie unter Beachtung material- und verfahrenstechnischer sowie ökologischer, ökonomischer und sozialer Aspekte ganzheitlich untersucht und bewertet. Auf Grundlage der dabei gewonnenen Erkenntnisse wird ein rechnergestütztes Analysetool zur Nachhaltigkeitsbewertung für das Mauerwerksrecycling entwickelt. Auf diesem Wege sollen im Sinne der aktuellen gesetzlichen Vorgaben nachhaltige Stoffkreisläufe im Mauerwerksbau geschlossen und somit letztlich die Deponierung von Mauerwerksrestmassen vermieden werden.------------------------------------------------------------------------------------------------------------------------------------------------- In Germany, a not unimportant quantity of masonry rubble is generated in the medium term. With regard to a sustainable closed substance cycle waste management, these rest masses have to be recycled if possible. Within the IGF research project “Sustainability Analysis for the Recycling of Masonry”, different recycling options will be assessed with regard to their sustainability performance. In doing so, the main kinds of masonry units (clay units, calcium silicate units, autoclaved aerated concrete units, aggregate concrete units), their material properties, the processing technologies as well as ecological, economic and social aspects will be considered. Based on the results, a web-based tool will be developed to assess the sustainability of different recycling options for masonry rubble. PY - 2012 DO - https://doi.org/10.1002/dama.201200549 SN - 1432-3427 SN - 1437-1022 VL - 16 IS - 5 SP - 242 EP - 246 PB - Ernst CY - Berlin AN - OPUS4-27392 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wang, L. A1 - Stebbings, R. A1 - Gaigalas, A.K. A1 - Sutherland, J. A1 - Kammel, M. A1 - John, M. A1 - Roemer, B. A1 - Kuhne, Maren A1 - Schneider, Rudolf A1 - Braun, M. A1 - Engel, A. A1 - Dikshit, D. A1 - Abbasi, F. A1 - Marti, G.E. A1 - Sassi, M. A1 - Revel, L. A1 - Kim, S.K. A1 - Baradez, M.-O. A1 - Lekishvili, T. A1 - Marshall, D. A1 - Whitby, L. A1 - Jing, W. A1 - Ost, V. A1 - Vonsky, M. A1 - Neukammer, J. T1 - Quantification of cells with specific phenotypes II: Determination of CD4 expression level on reconstituted lyophilized human PBMC labelled with anti-CD4 FITC antibody N2 - This report focuses on the characterization of CD4 expression level in terms of equivalent number of reference fluorophores (ERF). Twelve different flow cytometer platforms across sixteen laboratories were utilized in this study. As a first step the participants were asked to calibrate the fluorescein isothiocyanate (FITC) channel of each flow cytometer using commercially available calibration standard consisting of five populations of microspheres. Each population had an assigned value of equivalent fluorescein fluorophores (EFF denotes a special case of the generic term ERF with FITC as the reference fluorophore). The EFF values were assigned at the National Institute of Standards and Technology (NIST). A surface-labelled lyophilized cell preparation was provided by the National Institute of Biological Standards and Control (NIBSC), using human peripheral blood mononuclear cells (PBMC) pre-labeled with a FITC conjugated anti-CD4 monoclonal antibody. Three PBMC sample vials, provided to each participant, were used for the CD4 expression analysis. The PBMC are purported to have a fixed number of surface CD4 receptors. On the basis of the microsphere calibration, the EFF value of the PBMC samples was measured to characterize the population average CD4 expression level of the PBMC preparations. Both the results of data analysis performed by each participant and the results of centralized analysis of all participants' raw data are reported. Centralized analysis gave a mean EFF value of 22,300 and an uncertainty of 750, corresponding to 3.3% (level of confidence 68%) of the mean EFF value. The next step will entail the measurement of the ERF values of the lyophilized PBMC stained with labels for other fluorescence channels. The ultimate goal is to show that lyophilized PBMC is a suitable biological reference cell material for multicolor flow cytometry and that it can be used to present multicolor flow cytometry measurements in terms of ABC (antibodies bound per cell) units. KW - Surface labelled lyophilized PBMC KW - CD4 expression level KW - FITC KW - Equivalent fluorescein fluorophore (EFF) KW - Quantitative flow cytometry KW - Calibration KW - Standard measurement procedure KW - Measurement uncertainty KW - Reference cell material PY - 2015 DO - https://doi.org/10.1002/cyto.a.22634 SN - 0196-4763 SN - 1552-4922 SN - 1552-4930 VL - 87 IS - 3 SP - 254 EP - 261 PB - Wiley-Liss CY - Hoboken, NJ AN - OPUS4-32981 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Stebbings, R. A1 - Wang, L. A1 - Sutherland, J. A1 - Kammel, M. A1 - Gaigalas, A.K. A1 - John, M. A1 - Roemer, B. A1 - Kuhne, Maren A1 - Schneider, Rudolf A1 - Braun, M. A1 - Engel, A. A1 - Dikshit, D.K. A1 - Abbasi, F. A1 - Marti, G.E. A1 - Sassi, M.P. A1 - Revel, L. A1 - Kim, S.-K. A1 - Baradez, M.-O. A1 - Lekishvili, T. A1 - Marshall, D. A1 - Whitby, L. A1 - Jing, W. A1 - Ost, V. A1 - Vonsky, M. A1 - Neukammer, J. T1 - Quantification of cells with specific phenotypes I: Determination of CD4+ cell count per microliter in reconstituted lyophilized human PBMC prelabeled with anti-CD4 FICT antibody N2 - A surface-labeled lyophilized lymphocyte (sLL) preparation has been developed using human peripheral blood mononuclear cells prelabeled with a fluorescein isothiocyanate conjugated anti-CD4 monoclonal antibody. The sLL preparation is intended to be used as a reference material for CD4+ cell counting including the development of higher order reference measurement procedures and has been evaluated in the pilot study CCQM-P102. This study was conducted across 16 laboratories from eight countries to assess the ability of participants to quantify the CD4+ cell count of this reference material and to document cross-laboratory variability plus associated measurement uncertainties. Twelve different flow cytometer platforms were evaluated using a standard protocol that included calibration beads used to obtain quantitative measurements of CD4+ T cell counts. There was good overall cross-platform and counting method agreement with a grand mean of the laboratory calculated means of (301.7 ± 4.9) µL-1 CD4+ cells. Excluding outliers, greater than 90% of participant data agreed within ±15%. A major contribution to variation of sLL CD4+ cell counts was tube to tube variation of the calibration beads, amounting to an uncertainty of 3.6%. Variation due to preparative steps equated to an uncertainty of 2.6%. There was no reduction in variability when data files were centrally reanalyzed. Remaining variation was attributed to instrument specific differences. CD4+ cell counts obtained in CCQM-P102 are in excellent agreement and show the robustness of both the measurements and the data analysis and hence the suitability of sLL as a reference material for interlaboratory comparisons and external quality assessment. KW - CD4+ cell counting KW - Relative concentration measurement KW - Lyophilized cells KW - Flow cytometry KW - Standard measurement procedure KW - Measurement of uncertainty KW - Human immunodeficiency virus-1 KW - Acquired immunodeficiency syndrome KW - Reference material PY - 2015 DO - https://doi.org/10.1002/cyto.a.22614 SN - 0196-4763 SN - 1552-4922 SN - 1552-4930 VL - 87 IS - 3 SP - 244 EP - 253 PB - Wiley-Liss CY - Hoboken, NJ AN - OPUS4-32847 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Martínez, N.A. A1 - Schneider, Rudolf A1 - Messina, G.A. A1 - Raba, J. T1 - Modified paramagnetic beads in a microfluidic system for the determination of ethinylestradiol (EE2) in river water samples N2 - In this work, we have developed and characterized a novel microfluidic immunoassay methodology for rapid and sensitive quantification of ethinylestradiol (EE2) in river water samples. The detection of EE2 was carried out using a competitive direct immunoassay method based on the use of anti-EE2 polyclonal antibodies immobilized on magnetic microspheres 3-aminopropyl-modified manipulated for an external removable magnet. The EE2 present in the water sample was allowed to compete with EE2-horseradish peroxidase (HPR) conjugated for the immobilized anti-EE2 antibody. The HPR, in the presence of hydrogen peroxide (H2O2) catalyzes the oxidation of catechol (Q) whose back electrochemical reduction was detected on gold electrode at 0.0 V. The response current obtained from the product of enzymatic reaction is inversely proportional to the amount of EE2 in the water sample. The electrochemical detection can be done within 1 min and total assay time was 30 min. The calculated detection limits for electrochemical detection and the ELISA procedure are 0.09 and 0.32 ng L-1 respectively and the intra- and inter-assay coefficients of variation were below 5.8%. Our electrochemical immunosensor showed higher sensitivity and lower time consumed than the standard spectrophotometric detection ELISA method, which shows the potential for assessment of EE2 in river water samples. KW - Enzyme immunoassays KW - Ethinylestradiol KW - Paramagnetic beads KW - Horseradish peroxidase KW - Microfluidic KW - Flow injection analysis PY - 2010 DO - https://doi.org/10.1016/j.bios.2009.10.031 SN - 0956-5663 SN - 1873-4235 VL - 25 IS - 6 SP - 1376 EP - 1381 PB - Elsevier CY - Barking, Essex, UK AN - OPUS4-22188 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Martínez, N.A. A1 - Pereira, S.V. A1 - Bertolino, F.A. A1 - Schneider, Rudolf A1 - Messina, G.A. A1 - Raba, J. T1 - Electrochemical detection of a powerful estrogenic endocrine disruptor: ethylestradiol in water samples through bioseparation procedure N2 - The synthetic estrogen ethinylestradiol (EE2) is an active component of oral contraceptives (OCs), considered as an endocrine disrupting compound (EDC). It is excreted from humans and released via sewage treatment plant effluents into aquatic environments. EDCs are any environmental pollutant chemical that, once incorporated into an organism, affects the hormonal balance of various species including humans. Its presence in the environment is becoming of great importance in water quality. This paper describes the development of an accurate, sensitive and selective method for capture, preconcentration and determination of EE2 present in water samples using: magnetic particles (MPs) as bioaffinity support for the capture and preconcentration of EE2 and a glassy carbon electrode modified with multi-walled carbon nanotubes (MWCNTs/GCE) as detection system. The capture procedure was based on the principle of immunoaffinity, the EE2 being extracted from the sample using the anti-EE2 antibodies (anti-EE2 Ab) which were previously immobilized on MPs. Subsequently the analyte desorption was done employing a sulfuric acid solution and the determination of the EE2 in the pre-concentrated solution was carried out by square wave voltammetry (SWV). This method can be used to determine EE2 in the range of 0.035–70 ng L-1 with a detection limit (LOD) of 0.01 ng L-1 and R.S.D. < 4.20%. The proposed method has been successfully applied to the determination of EE2 in water samples and it has promising analytical applications for the direct determination of EE2 at trace levels. KW - Magnetic particles KW - Bioseparation KW - Ethinylestradiol KW - Electrochemistry KW - Immunoassay KW - Elektrochemischer Sensor KW - Endokrine Disruptoren KW - Hormone KW - EE2 KW - Östrogene PY - 2012 DO - https://doi.org/10.1016/j.aca.2012.02.033 SN - 0003-2670 SN - 1873-4324 SN - 0378-4304 VL - 723 SP - 27 EP - 32 PB - Elsevier CY - Amsterdam AN - OPUS4-25656 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pulz, Robert A1 - Rehmer, Birgit A1 - Schneider, G.A. A1 - Skrotzki, Birgit T1 - Thermal shock study on different advanced ceramics by laser irradiation in different media N2 - The thermal shock behavior of three commercial-advanced ceramics (SSiC, MgO–PSZ, Al2O3) is characterized in air and vacuum applying a laser thermal shock. The available testing system permits the reproducible setting of defined temperature profiles in thin disks and allows a heating-up thermal shock in various media. Due to the accurate determination of the time- and space-resolved temperature distribution, the local stress state can be calculated as a function of time. It is shown that the thermal shock strength is highest for SSiC and lowest in Al2O3 with MgO–PSZ in between. The approach presented in this work allows quantifying the stress state at failure in terms of tangential tensile stress. The investigated environment does not affect the thermal shock resistance under the studied experimental conditions. KW - Laser-thermal shock KW - Advanced ceramic KW - Stress distribution KW - Thermal shock stress KW - Weibull statistics PY - 2016 UR - http://onlinelibrary.wiley.com/doi/10.1002/adem.201500162/full DO - https://doi.org/10.1002/adem.201500162 SN - 1438-1656 VL - 18 IS - 1 SP - 132 EP - 140 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-33456 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -