TY - JOUR A1 - Vogl, Jochen A1 - Kipphardt, Heinrich A1 - Richter, Silke A1 - Bremser, Wolfram A1 - Arvizu Torres, M. A1 - Lara Manzano, J. A1 - Buzoianu, M. A1 - Hill, S. A1 - Petrov, P. A1 - Goenaga-Infante, H. A1 - Sargent, M. A1 - Fisicaro, P. A1 - Labarraque, G. A1 - Zhou, T. A1 - Turk, G. C. A1 - Winchester, M. A1 - Miura, T. A1 - Methven, B. A1 - Sturgeon, R. A1 - Jährling, R. A1 - Rienitz, O. A1 - Mariassy, M. A1 - Hankova, Z. A1 - Sobina, E. A1 - Krylov, A. I. A1 - Kustikov, Y. A. A1 - Smirnov, V. V. T1 - Establishing comparability and compatibility in the purity assessment of high purity zinc as demonstrated by the CCQM-P149 intercomparison N2 - For the first time, an international comparison was conducted on the determination of the purity of a high purity element. Participants were free to choose any analytical approach appropriate for their institute’s applications and services. The material tested was a high purity zinc, which had earlier been assessed for homogeneity and previously used in CCQM-K72 for the determination of six defined metallic impurities. Either a direct metal assay of the Zn mass fraction was undertaken by EDTA titrimetry, or an indirect approach was used wherein all impurities, or at least the major ones, were determined and their sum subtracted from ideal purity of 100 %, or 1 kg/kg. Impurity assessment techniques included glow discharge mass spectrometry, inductively coupled plasma mass spectrometry and carrier gas hot extraction/combustion analysis. Up to 91 elemental impurities covering metals, non-metals and semi-metals/metalloids were quantified. Due to the lack of internal experience or experimental capabilities, some participants contracted external laboratories for specific analytical tasks, mainly for the analysis of non-metals. The reported purity, expressed as zinc mass fraction in the high purity zinc material, showed excellent agreement for all participants, with a relative standard deviation of 0.011 %. The calculated reference value, w(Zn) = 0.999 873 kg/kg, was assigned an asymmetric combined uncertainty of + 0.000025 kg/kg and – 0.000028 kg/kg. Comparability amongst participating metrology institutes is thus demonstrated for the purity determination of high purity metals which have no particular difficulties with their decomposition / dissolution process when solution-based analytical methods are used, or which do not have specific difficulties when direct analysis approaches are used. Nevertheless, further development is required in terms of uncertainty assessment, quantification of non-metals and the determination of purity of less pure elements and/or for those elements suffering difficulties with the decomposition process. KW - Purity assessment KW - Direct metal assay KW - Impurity assessment KW - Non-metal analysis KW - High-purity elements KW - SI-traceability PY - 2018 DO - https://doi.org/10.1088/1681-7575/aaa677 SN - 1681-7575 SN - 0026-1394 VL - 55 IS - 2 SP - 211 EP - 221 PB - Institute of Physics Publishing CY - Bristol AN - OPUS4-44257 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mühler, T. A1 - Helsch, G. A1 - Heinrich, J.G. A1 - Yao, Dongxu A1 - Gräf, S. A1 - Müller, F.A. A1 - Günster, Jens T1 - Strategies for the selective volume sintering of ceramics N2 - The present study is dealing with the basic physics for a novel way to generate a free-formed ceramic body, not like common layer by layer, but directly by Selective Volume Sintering (SVS) in a compact block of ceramic powder. To penetrate with laser light into the volume of a ceramic powder compact it is necessary to investigate the light scattering properties of ceramic powders. Compared with polymers and metals, ceramic materials are unique as they offer a wide optical window of transparency. The optical window typically ranges from below 0.3 up to 5 µm wave length. In the present study thin layers of quartz glass (SiO2) particles have been prepared. As a function of layer thickness and the particle size, transmission and reflection spectra in a wave length range between 0.5 and 2.5 µm have been recorded. Depending on the respective particle size and by choosing a proper relation between particle size and wave length of the incident laser radiation, it is found that light can penetrate a powder compact up to a depth of a few millimeters. With an adjustment of the light absorption properties of the compact the initiation of sintering in the volume of the compact is possible. KW - Additive Manufacturing PY - 2014 DO - https://doi.org/10.1557/jmr.2014.174 SN - 0884-2914 VL - 29 IS - 17 SP - 2095 EP - 2099 PB - Materials Research Society CY - Warrendale, Pa. AN - OPUS4-32544 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lahiri, D. A1 - Sharma, S.M. A1 - Verma, A.K. A1 - Vishwanadh, B. A1 - Dey, G.K. A1 - Schumacher, G. A1 - Scherb, T. A1 - Riesemeier, Heinrich A1 - Reinholz, Uwe A1 - Radtke, Martin A1 - Banerjee, S. T1 - Investigation of short-range structural order in Zr69.5Cu12Ni11Al7.5 and Zr41.5Ti41.5Ni17 glasses, using X-ray absorption spectroscopy and ab initio molecular dynamics simulations N2 - Short-range order has been investigated in Zr69.5Cu12Ni11Al7.5 and Zr41.5Ti41.5Ni17 metallic glasses using X-ray absorption spectroscopy and ab initio molecular dynamics simulations. While both of these alloys are good glass formers, there is a difference in their glass-forming abilities (Zr41.5Ti41.5Ni17 > Zr69.5Cu12Ni11Al7.5). This difference is explained by inciting the relative importance of strong chemical order, icosahedral content, cluster symmetry and configuration diversity. KW - Multi-component alloy KW - Glass-forming ability KW - XAFS KW - Local structure KW - AIMD simulation PY - 2014 DO - https://doi.org/10.1107/S1600577514017792 SN - 0909-0495 SN - 1600-5775 VL - 21 IS - 6 SP - 1296 EP - 1304 PB - Blackwell Publishing CY - Oxford AN - OPUS4-31837 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kipphardt, Heinrich A1 - Matschat, Ralf A1 - Vogl, Jochen A1 - Gusarova, Tamara A1 - Czerwensky, Michael A1 - Heinrich, Hans-Joachim A1 - Hioki, A. A1 - Konopelko, L.A. A1 - Methven, B. A1 - Miura, T. A1 - Petersen, O. A1 - Riebe, Gundel A1 - Sturgeon, R. A1 - Turk, G.C. A1 - Yu, L. L. T1 - Purity determination as needed for the realisation of primary standards for elemental determination: status of international comparability N2 - Within the National Metrology Institutes (NMIs) and designated laboratories, an interlaboratory comparison, CCQM-P107, was conducted to verify the degree of international comparability concerning the results of purity analysis. The mass fractions of Ag, Bi, Cd, Cr, Ni, Tl at the lower mg/kg-level in a high purity zinc material were determined, but the real measurand in metrological sense was the sum of the six mass fractions. Homogeneity was investigated by glow discharge mass spectrometry, reference values were obtained using isotope dilution mass spectrometry. Six NMIs participated, contributing eight independent data sets. The agreement amongst the results of the participants, their median and the agreement with the reference values were usually excellent and in almost all cases below the target uncertainty of 30% relative. In this manner, the accuracy of results and the comparability between the participants was demonstrated to be established. KW - Interlaboratory comparison KW - Purity analysis KW - High purity metals KW - CCQM-P107 KW - Zinc PY - 2010 DO - https://doi.org/10.1007/s00769-009-0557-0 SN - 0949-1775 SN - 1432-0517 VL - 15 IS - 1 SP - 29 EP - 37 PB - Springer CY - Berlin AN - OPUS4-20767 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Görner, Wolf A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. A1 - Riesemeier, Heinrich A1 - Krumrey, M. A1 - Ulm, G. T1 - The first hard X-rays at the BAMline PY - 2001 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2000.pdf#page=329 SN - 0179-4159 SP - 329 EP - 331 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-1299 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Bernd R. A1 - Görner, Wolf A1 - Hentschel, Manfred P. A1 - Riesemeier, Heinrich A1 - Krumrey, M. A1 - Ulm, G. A1 - Diete, W. A1 - Klein, U. A1 - Frahm, R. T1 - BAMlin - the first hard X-ray beamline at BESSY II N2 - The first hard X-ray beamline at BESSY II will be installed by BAM and PTB at a superconducting 7 T wavelength shifter. The main optical elements of the beamline are a Double-Multilayer-Monochromator and a Double-Crystal-Monochromator. The two devices can be used separately or in-line. Main applications of monochromatic radiation with photon energies up to 50 keV are X-ray fluorescence analysis, micro-computed tomography, X-ray topography, detector calibration and reflectometry. Calculable undispersed radiation up to 200 keV will be available for radiometric applications. KW - Double-Multilayer-Monochromator with meridional bender KW - Double-Crystal-Monochromator with sagittal bender KW - X-ray fluorescence analysis KW - Micro-computed tomography KW - X-ray topography KW - Detector calibration KW - Reflectometry PY - 2001 DO - https://doi.org/10.1016/S0168-9002(01)00466-1 SN - 0168-9002 SN - 0167-5087 VL - 467-468 IS - 1 SP - 703 EP - 706 PB - North-Holland CY - Amsterdam AN - OPUS4-1171 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fischer, G. A1 - Nellesen, J. A1 - Anar, N. B. A1 - Ehrig, Karsten A1 - Riesemeier, Heinrich A1 - Tillmann, W. T1 - 3D analysis of micro-deformation in VHCF-loaded nodular cast iron by µCT N2 - The impact of very high cycle fatigue (VHCF) load conditions on the microstructure of specimens consisting of nodular cast iron is analyzed by means of micro-computed tomography (µCT) utilizing both monochromatic synchrotron radiation and polychromatic X-ray tube radiation. Using 3D µCT, the microstructure in the region of the smallest cross-sections of shouldered round specimens is imaged in different stages of the VHCF loading. By digital image correlation (DIC) of these tomograms strain fields are analyzed three-dimensionally. Strain levels in the range of a few percent were detected. It is proven that a localization of strain allows to predict the site of the crack which precedes and induces the macroscopic failure of the specimens. KW - VHCF (very high cycle fatigue) KW - µCT KW - Micro-computed tomography KW - Strain analysis KW - Nodular cast iron PY - 2013 DO - https://doi.org/10.1016/j.msea.2013.04.057 SN - 0921-5093 SN - 1873-4936 VL - 577 SP - 202 EP - 209 PB - Elsevier CY - Amsterdam AN - OPUS4-28533 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Paris, O. A1 - Li, C. A1 - Siegel, S. A1 - Weseloh, G. A1 - Emmerling, Franziska A1 - Riesemeier, Heinrich A1 - Erko, A. A1 - Fratzl, P. T1 - A new experimental station for simultaneous X-ray microbeam scanning for small- and wide-angle scattering and fluorescence at BESSY II N2 - A new instrument for simultaneous microbeam small- and wide-angle X-ray scattering and X-ray fluorescence (SAXS/WAXS/XRF) is presented. The instrument is installed at the microfocus beamline at BESSY II and provides a beam of 10 µm size with a flux of about 109 photons s-1. A SAXS resolution up to 500 Å d-spacing and a range of scattering vectors of almost three orders of magnitude are reached by using a large-area high-resolution CCD-based detector for simultaneous SAXS/WAXS. The instrument is particularly suited for scanning SAXS/WAXS/XRF experiments on hierarchically structured biological tissues. The necessary infrastructure, such as a cryo-stream facility and an on-site preparation laboratory for biological specimens, are available. KW - Scanning SAXS KW - Scanning WAXS KW - Microbeam KW - Synchrotron radiation PY - 2007 SN - 0021-8898 SN - 1600-5767 VL - 40 IS - Supplement SP - s466 EP - s470 PB - Blackwell CY - Oxford AN - OPUS4-15049 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mechler, S. A1 - Schumacher, G. A1 - Koteski, V. A1 - Riesemeier, Heinrich A1 - Schäfers, F. A1 - Mahnke, H.-E. T1 - Local structure and site substitution in amorphous and quasicrystalline Zr-Ti-Ni-(Cu) alloys N2 - Local structures of amorphous and quasicrystalline phases in Zr–Ti–Ni and Zr–Ti–Ni–Cu alloys have been studied by means of x-ray absorption spectroscopy. The amorphous phases show a high degree of icosahedral short-range order. In all investigated systems local order around Cu and Ni atoms was found to be nearly identical pointing to site substitution of Ni by Cu as the reason for an improved glass forming ability when Ni is partly substituted by Cu. The results strengthen an icosahedral cluster based approach for the structure of metallic glasses and indicate the importance of the medium-range order on glass formation. KW - Copper alloys KW - Frustration KW - Glass structure KW - Metallic glasses KW - X-ray absorption spectra PY - 2010 DO - https://doi.org/10.1063/1.3467265 SN - 0003-6951 SN - 1077-3118 VL - 97 IS - 4 SP - 041914-1 - 041914-3 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-22122 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schott, M. A1 - Szczerba, Wojciech A1 - Posset, U. A1 - Vuk, A.S. A1 - Beck, M. A1 - Riesemeier, Heinrich A1 - Thünemann, Andreas A1 - Kurth, D. G. T1 - In operando XAFS experiments on flexible electrochromic devices based on Fe(II)-metallo-supramolecular polyelectrolytes and vanadium oxides N2 - Flexible electrochromic devices (ECDs) based on Fe(II)-metallo-supramolecular polyelectrolytes (Fe-MEPE) and vanadium oxide are studied in operando by means of x-ray absorption fine structure (XAFS) spectroscopy. The ECDs are blue-purple in the colored state at 0.0 V and become light yellow when a voltage of 1.6 V is applied. The XAFS studies at the K-edge of Fe(II) reveals that the absorption edge is shifted toward higher energies by 1.8 eV in the transparent state. Comparison of two different ECDs and different charge cycles demonstrates the reversibility and repeatability of the process. We attribute the shift to a charge transfer and a change of oxidation state of the ions from Fe2+ to Fe3+. The transition is not accompanied by a noticeable structural change of the octahedral coordination geometry as confirmed by analysis of the extended x-ray absorption fine structure (EXAFS) data. (C) 2015 Elsevier B.V. All rights reserved. KW - Metallo-supramolecular polyelectrolytes KW - Vanadium oxide KW - Electrochromism KW - Electrochromic device KW - Cyclic voltammetry KW - XAFS PY - 2016 DO - https://doi.org/10.1016/j.solmat.2015.10.015 SN - 0927-0248 VL - 147 SP - 61 EP - 67 PB - Elsevier B.V. CY - Amsterdam [u.a.] AN - OPUS4-35251 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Purohit, Purv A1 - Huacuja Sánchez, Jesús A1 - Wang, D.-Y. A1 - Emmerling, Franziska A1 - Thünemann, Andreas A1 - Heinrich, G. A1 - Schönhals, Andreas T1 - Structure - property relationships of nanocomposites based on polypropylene and layered double hydroxides N2 - Nanocomposites based on polypropylene (PP) and organically modified ZnAl layered double hydroxides (ZnAl-LDH) were prepared by melt blending and investigated by a combination of differential scanning calorimetry (DSC), small- and wide-angle X-ray scattering (SAXS and WAXS), and dielectric relaxation spectroscopy (DRS). An average number of stack size of LDH layers is calculated by analyzing the SAXS data which is close to that of pure organically modified ZnAl-LDH. Scanning microfocus SAXS investigations show that the ZnAl-LDH is homogeneously distributed in the PP matrix as stacks of 4–5 layers with an intercalated morphology. DSC and WAXS results show that the degree of crystallinity decreases linearly with the increasing content of LDH. The extrapolation of this dependence to zero estimates a limiting concentration of ca. 40% LDH where the crystallization of PP is completely suppressed by the nanofiller. The dielectric spectra of the nanocomposites show several relaxation processes which are discussed in detail. The intensity of the dynamic glass transition (β-relaxation) increases with the concentration of LDH. This is attributed to the increasing concentration of the exchanged anion dodecylbenzenesulfonate (SDBS) which is adsorbed at the LDH layers. Therefore, a detailed analysis of the β-relaxation provides information about the structure and the molecular dynamics in the interfacial region between the LDH layers and the polypropylene matrix which is otherwise dielectrically invisible (low dipole moment). As a main result, it is found that the glass transition temperature in this interfacial region is by 30 K lower than that of pure polypropylene. This is accompanied by a drastic change of the fragility parameter deduced from the relaxation map. KW - Nanocomposites KW - Layered double hydroxide KW - Dielectric spectroscopy KW - X-ray scattering KW - Polypropylene PY - 2011 DO - https://doi.org/10.1021/ma200323k SN - 0024-9297 SN - 1520-5835 VL - 44 IS - 11 SP - 4342 EP - 4354 PB - American Chemical Society CY - Washington, DC AN - OPUS4-23921 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Purohit, Purv A1 - Wang, D.-Y. A1 - Emmerling, Franziska A1 - Thünemann, Andreas A1 - Heinrich, G. A1 - Schönhals, Andreas T1 - Arrangement of layered double hydroxide in a polyethylene matrix studied by a combination of complementary methods N2 - Organically modified ZnAl Layered Double Hydroxides (ZnAl-LDH) was synthesized and melt blended with polyethylene to obtain nanocomposites. The resulting morphology was investigated by a combination of Differential Scanning Calorimetry (DSC), Small and Wide-angle X-ray scattering (SAXS and WAXS) and dielectric relaxation spectroscopy (DRS). The arrangement (intercalation) of polyethylene chains between LDH stacks was investigated employing SAXS. The homogeneity of the nanocomposites and average number of stack size (4–6 layers) were determined using scanning microfocus SAXS (BESSY II). DSC and WAXS results show that the degree of crystallinity decreases linearly with the increasing content of LDH. The extrapolation of this dependence to zero estimates a limiting concentration of ca. 45% LDH where the crystallization of PE is completely suppressed by the nanofiller. The dielectric spectra of the nanocomposites show several relaxation processes which are discussed in detail. The intensity of the dynamic glass transition (β-relaxation) increases with the concentration of LDH. This is attributed to the increasing concentration of the exchanged anion sodium dodecylbenzene sulfonate (SDBS) which is adsorbed at the LDH layers. Therefore, a detailed analysis of the β-relaxation provides information about the structure and the molecular dynamics in the interfacial region between the LDH layers and the polyethylene matrix which is otherwise dielectrically invisible (low dipole moment). KW - Dielectric spectroscopy KW - Polyethylene nanocomposites KW - Layered double hydroxides PY - 2012 DO - https://doi.org/10.1016/j.polymer.2012.03.041 SN - 0032-3861 SN - 1873-2291 VL - 53 IS - 11 SP - 2245 EP - 2254 PB - Springer CY - Berlin AN - OPUS4-25810 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mandel, K. A1 - Szczerba, Wojciech A1 - Thünemann, Andreas A1 - Riesemeier, Heinrich A1 - Girod, Matthias A1 - Sextl, G. T1 - Nitric acid-stabilized superparamagnetic iron oxide nanoparticles studied with X-rays N2 - Agglomerated superparamagnetic iron oxide nanoparticles can easily and in large scale be precipitated from iron salt solutions. Although the process is well known, it is ambiguously either assumed that magnetite or maghemite is obtained. The first part of our study clarifies this question using X-ray absorption spectroscopy. For further processing of the nanoparticles, i.e., for giving them a surface functionality or incorporating them into composites, it is important to break the agglomerates and individualize the particles at first. This can effectively be done with nitric acid treatment. The influence of this process on the particles chemistry and structure was analyzed in great detail using X-ray diffraction, X-ray absorption, and smallangle X-ray scattering. In contrast to our expectation, no oxidation from magnetite (Fe3O4) to maghemite (γ- Fe2O3) was found; the formal valence of the particles in any case is magnetite (Fe3O4). Instead, an increase in the particles' surface disorder was discovered from X-ray absorption analyses and high-resolution transmission electron microscopy. The acid treatment roughens and distorts the surface of the nanoparticles which is connected with an increased spin disorder. KW - XANES KW - EXAFS KW - SAXS KW - Coprecipitation KW - Iron oxide spectra KW - Ferrofluid PY - 2012 DO - https://doi.org/10.1007/s11051-012-1066-3 SN - 1388-0764 SN - 1572-896X VL - 14 IS - 8 SP - 1066/1 EP - 9 PB - Kluwer CY - Dordrecht AN - OPUS4-26357 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Heidt, Heinrich A1 - Basler, G. T1 - Belichtungsrechner für technische Radiographie T2 - 2. Europäische Tagung für Zerstörungsfreie Prüfung CY - Wien DA - 1981-09-14 PY - 1981 SP - 163 EP - 164 CY - Wien AN - OPUS4-33313 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Shipov, A. A1 - Zaslansky, P. A1 - Riesemeier, Heinrich A1 - Segev, G. A1 - Atkins, A. A1 - Shahar, R. T1 - Unremodeled endochondral bone is a major architectural component of the cortical bone of the rat (Rattus norvegicus) N2 - The laboratory rat is one of the most frequently-used animal models for studying bone biology and skeletal diseases. Here we show that a substantial portion of the cortical bone of mature rats is primary endochondral bone, consisting of a disorganized arrangement of mineralized collagen fibers. We characterize the structure and mechanical properties of the cortical bone of the rat. We show that the cortical bone consists of two architecturally distinct regions. One region, consisting of well-organized circumferential lamellae (CLB), is located in the endosteal and/or the periosteal regions while another, disorganized region, is located in the more central region of the cortex. Unexpectedly, we found that the disorganized region contains many islands of highly mineralized cartilage. Micro tomography showed different structural and compositional properties of the two primary structural elements; the CLB region has lower mineral density, lower porosity, larger but fewer blood vessels and fewer lacunae. However, no difference was found in the average lacunar volume. Additionally the mean indentation modulus of the CLB region was lower than that of the disorganized region. The islands of calcified cartilage were found to be extremely stiff, with an indentation modulus of 33.4 ± 3.5 GPa. We conclude that though the cortical bone of rats is in part lamellar, its architecture is markedly different from that of the cortical bone of humans, a fact that must be borne in mind when using the rat as a model animal for studies of human bone biology and disease. KW - Cortical bone KW - Endochondral bone KW - Lamellar bone KW - Disorganized bone KW - Cartilage islands KW - Cortical bone structure KW - Synchrotron based microtomography KW - Mechanical properties PY - 2013 DO - https://doi.org/10.1016/j.jsb.2013.04.010 SN - 1047-8477 SN - 1095-8657 VL - 183 IS - 2 SP - 132 EP - 140 PB - Elsevier CY - San Diego, Calif. AN - OPUS4-30547 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - D'Agostino, G. A1 - Bergamaschi, L. A1 - Giordani, L. A1 - Oddone, M. A1 - Kipphardt, Heinrich A1 - Richter, Silke T1 - Use of instrumental neutron activation analysis to investigate the distribution of trace elements among subsamples of solid materials N2 - The results of analytical measurements performed with solid-sampling techniques are affected by the distribution of the analytes within the matrix. The effect becomes significant in case of determination of trace elements in small subsamples. In this framework we propose a measurement model based on Instrumental Neutron Activation Analysis to determine the relative variability of the amount of an analyte among subsamples of a material. The measurement uncertainty is evaluated and includes the counting statistics, the full-energy gamma peak efficiency and the spatial gradient of the neutron flux at the irradiation position. The data we obtained in a neutron activation experiment and showing the relative variability of As, Au, Ir, Sb and W among subsamples of a highly pure Rh foil are also presented. KW - Instrumental neutron activation analysis KW - Homogeneity KW - Rhodium KW - Uncertainty PY - 2014 SN - 0026-1394 SN - 1681-7575 VL - 51 SP - 1 EP - 6 PB - Inst. of Physics Publ. CY - Bristol AN - OPUS4-30302 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schönhals, Andreas A1 - Goering, Harald A1 - Costa, F. R. A1 - Wagenknecht, U. A1 - Heinrich, G. T1 - Dielectric properties of nanocomposites based on polyethylene and layered double hydroxide N2 - Nanocomposites with a predominantly exfoliated morphology were prepared by melt blending of organically modified doubled layered hydroxide (LDH) and low density polyethylene (PE). The prepared materials were investigated by differential scanning calorimetry (DSC) and in detail by dielectric spectroscopy. The DSC experiments show that the degree of crystallinity decreases linearly with increasing content of the LDH. The extrapolation of this dependence to zero results in a limiting concentration of ca. 50 wt % LDH were the crystallization of PE is completely suppressed by the nanofiller. The dielectric response of pure polyethylene shows different weak relaxation processes. The intensity of dynamic glass transition (β-relaxation) increases with the concentration of LDH. This is attributed to the increasing concentration of the exchanged anion dodecyl benzene sulfonate (SDBS). The SDBS molecules are strongly adsorbed at the exfoliated LDH layers. Therefore, a detailed analysis of the β-relaxation provides information about the structure and the molecular dynamics in the interfacial region between the exfoliated LDH layers and the polyethylene matrix. This analysis shows that the β-relaxation region consists of two processes: both of them obey glassy dynamics. The difference in corresponding Vogel (ideal glass transition) temperatures is about 30 K. The relaxation process at lower frequency is assigned to polyethylene segments with a reduced molecular mobility close to LDH layers. The process at higher frequencies is related to polyethylene segments in a farer distance for the surface of the nanofiller. In the nanocomposite materials an additional process due to Maxwell-Wagner-Sillars (MWS) polarization was observed. The time constant of this MWS process can be correlated with characteristic length scales in nanocomposites and therefore provides additional information on dispersion and delamination/exfoliation of the LDH layers in these materials. PY - 2009 DO - https://doi.org/10.1021/ma900077w SN - 0024-9297 SN - 1520-5835 VL - 42 IS - 12 SP - 4165 EP - 4174 PB - American Chemical Society CY - Washington, DC AN - OPUS4-19594 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wang, D. A1 - Costa, F. R. A1 - Leuteritz, A. A1 - Purohit, Purv A1 - Schönhals, Andreas A1 - Vyalikh, A. A1 - Scheler, U. A1 - Wagenknecht, U. A1 - Kutlu, B. A1 - Heinrich, G. ED - Mittal, V. T1 - Polyolefin nanocomposites with layered double hydroxides PY - 2010 SN - 978-1-4398-1454-3 SP - 225 EP - 245 PB - CRC Press AN - OPUS4-23039 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Markötter, H. A1 - Manke, I. A1 - Hartnig, C. A1 - Krüger, P. A1 - Wippermann, K. A1 - Arlt, Tobias A1 - Choinka, G. A1 - Riesemeier, Heinrich A1 - Banhart, J. T1 - Hochauflösende Synchrotron-Radiografie KW - PEM Fuel-cells KW - Local current distribution KW - Neutron imaging technique KW - Water transport PY - 2010 SN - 0025-5300 VL - 52 IS - 10 SP - 698 EP - 704 PB - Hanser CY - München AN - OPUS4-23046 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kaltenbach, A. A1 - Nordmann, J. A1 - Görlitz, V. A1 - Pape, C. A1 - Richter, Silke A1 - Kipphardt, Heinrich A1 - Kopp, G. A1 - Jährling, R. A1 - Rienitz, O. A1 - Güttler, B. T1 - Gravimetric preparation and characterization of primary reference solutions of molybdenum and rhodium N2 - Gravimetrically prepared mono-elemental reference solutions having a well-known mass fraction of approximately 1 g/kg (or a mass concentration of 1 g/L) define the very basis of virtually all measurements in inorganic analysis. Serving as the starting materials of all standard/calibration solutions, they link virtually all measurements of inorganic analytes (regardless of the method applied) to the purity of the solid materials (high-purity metals or salts) they were prepared from. In case these solid materials are characterized comprehensively with respect to their purity, this link also establishes direct metrological traceability to The International System of Units (SI). This, in turn, ensures the comparability of all results on the highest level achievable. Several national metrology institutes (NMIs) and designated institutes (DIs) have been working for nearly two decades in close cooperation with commercial producers on making an increasing number of traceable reference solutions available. Besides the comprehensive characterization of the solid starting materials, dissolving them both loss-free and completely under strict gravimetric control is a challenging problem in the case of several elements like molybdenum and rhodium. Within the framework of the European Metrology Research Programme (EMRP), in the Joint Research Project (JRP) called SIB09 Primary standards for challenging elements, reference solutions of molybdenum and rhodium were prepared directly from the respective metals with a relative expanded uncertainty associated with the mass fraction of Urel(w)<0.05 %. To achieve this, a microwave-assisted digestion procedure for Rh and a hotplate digestion procedure for Mo were developed along with highly accurate and precise inductively coupled plasma optical emission spectrometry (ICP OES) and multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) methods required to assist with the preparation and as dissemination tools. KW - Digestion KW - Rhodium KW - Molybdenum KW - Reference solution KW - Metrological traceability KW - ICP OES KW - MC-ICP-MS PY - 2015 DO - https://doi.org/10.1007/s00216-014-8395-2 SN - 1618-2642 SN - 1618-2650 VL - 407 IS - 11 SP - 3093 EP - 3102 PB - Springer CY - Berlin AN - OPUS4-33065 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -