TY - JOUR A1 - Ma, L. A1 - Feng, L. A1 - Hioki, A. A1 - Cho, K.H. A1 - Vogl, Jochen A1 - Berger, Achim A1 - Turk, G. A1 - Macleod, S. A1 - Labarraque, G. A1 - Tong, W.F. A1 - Schiel, D. A1 - Yafa, C. A1 - Valiente, L. A1 - Konopelko, L.A. A1 - Quetel, C. A1 - Vermaercke, P. A1 - Manzano, J.V.L. A1 - Linsky, M. A1 - Cortés, E. A1 - Tangpitayakul, S. A1 - Plangsangmas, L. A1 - Bergamaschi, L. A1 - Hearn, R. T1 - International comparison of the determination of the mass fraction of cadmium, chromium, mercury and lead in polypropylene: the Comité Consultatif pour la quantité de matière pilot study CCQM-P106 KW - Cadmium KW - Chromium KW - Mercury KW - Lead KW - Polypropylene KW - CCQM PY - 2010 DO - https://doi.org/10.1007/s00769-009-0574-z SN - 0949-1775 SN - 1432-0517 VL - 15 IS - 1 SP - 39 EP - 44 PB - Springer CY - Berlin AN - OPUS4-20787 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Knabe, C. A1 - Gildenhaar, Renate A1 - Berger, R. A1 - Ostapowicz, W. A1 - Fitzner, R. A1 - Radlanski, R. A1 - Gross, U. A1 - Siebert, G. T1 - In vitro examination of novel calcium phosphates using osteogenic cultures T2 - 5th World Biomaterials Congress CY - Toronto, Canada DA - 1996-05-29 KW - In-vitro Untersuchung KW - Kalzium-Phosphat KW - Zahnersatz KW - Knochen PY - 1996 VL - 1 SP - 890 CY - Toronto AN - OPUS4-672 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Driessens, F. C. M. A1 - Boltong, M. G. A1 - Fernández, E. A1 - Ginebra, M. P. A1 - Planell, J. A. A1 - Verbeeck, R. M. H. A1 - De Maeyer, E. A. P. A1 - Berger, Georg T1 - Amorphous calcium phosphate cements T2 - 5th World Biomaterials Congress CY - Toronto, Canada DA - 1996-05-29 KW - Kalzium Phosphat Zement, amorph. PY - 1996 VL - 2 SP - 346 CY - Toronto AN - OPUS4-673 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Berger, Georg A1 - Steinhauser, E. A1 - Willmann, G. A1 - Liesner, C. A1 - Willems, U. A1 - Grössl, H. T1 - Biokompatible Werkstoffe - Ersatzteile für Menschen T2 - Podiumsdiskussion zur Materialica 2000 CY - München, Deutschland DA - 2000-09-26 PY - 2000 AN - OPUS4-918 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Berger, Georg A1 - Ploska, Ute A1 - Willmann, G. T1 - Hydroxyapatite's Solubility May Cause Loosening of Coated Implants KW - pH Value KW - Solubility KW - Coated Implants KW - Hydroxyapatite PY - 2001 SN - 1013-9826 VL - 192-195 SP - 111 EP - 114 PB - Trans Tech Publ. CY - Aedermannsdorf AN - OPUS4-1045 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Driessens, F. C. M. A1 - De Maeyer, E. A. P. A1 - Fernández, E. A1 - Boltong, M. G. A1 - Berger, Georg A1 - Verbeeck, R. M. H. A1 - Ginebra, M. P. A1 - Planell, J. A. T1 - Amorphous calcium phosphate cements and their transformation into calcium deficient hydroxyapatite KW - Zement KW - Kalzium-Phosphat PY - 1996 VL - 9 SP - 231 EP - 234 AN - OPUS4-704 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Berger, Georg A1 - Ploska, Ute A1 - Willmann, G. T1 - Auflösung von Hydroxylapatit-Beschichtung durch Entzündung PY - 2001 SN - 1616-0177 SN - 0011-8656 VL - 2 IS - 2-3 SP - - PB - Verl. Neuer Merkur CY - München AN - OPUS4-1142 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Berger, L.-M. A1 - Woydt, Mathias A1 - Keller, H. A1 - Zimmermann, S. A1 - Schwier, G. A1 - Enzl, R. A1 - Thiele, S. T1 - Tribological behaviour of HVOF-sprayed Cr3C2-NiCr and TiC-based coatings under high temperature dry sliding conditions N2 - In the current study, the tribological properties of TiC-based coatings paired with polycrystalline alumina under unlubricated sliding conditions were investigated in order to demonstrate the technological and engineering potential of such coatings. (Ti,Mo)(C,N)-Co coatings were prepared from an agglomerated and sintered spray powder by HVOF spraying using JP-5000 equipment. Cr3C2-NiCr coatings were studied for comparison. Sliding wear tests were performed over the temperature range from 23°C to 800°C with sliding speeds in the range 0.3-3 m/s, a wear distance of 5000 m and a normal force of 10 N. Wear rates of coatings and sintered alumina counterparts were measured separately. Compared with Cr3C2-NiCr coatings, (Ti,Mo)(C,N)-Co coatings showed significantly lower total wear rates, corresponding to those found in the region of mixed/boundary lubrication. With few exceptions, the coefficients of friction were found to be lower for (Ti,Mo)(C,N)-Co coatings than for Cr3C2-NiCr coatings. After tests were performed, the coating microstructures were studied by optical microscopy and SEM. The oxide scales formed on the coating surfaces were investigated by SEM and X-ray diffraction. Comparison of the total wear rates of the couples consisting of sintered alumina and a (Ti,Mo)(C,N)-Co coating with those of other alumina-ceramic and hardmetal-hard metal tribological systems demonstrates the immense potential of TiC-based coatings for sliding wear applications. T2 - International Thermal Spray Conference & Exposition 2004 CY - Osaka, Japan DA - 2004-05-10 PY - 2004 SN - 3-87155-792-7 SP - 1(?) EP - 10(?) PB - DVS-Verl. CY - Düsseldorf AN - OPUS4-5123 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Berger, Achim A1 - Alber, D. A1 - Bukalis, G. T1 - Determination of cobalt in nickel in the sub-ppm level with cold neutrons KW - Neutronenaktivierungsanalyse KW - Neutronenstrahl KW - Referenzmaterialien PY - 2007 SN - 0236-5731 SN - 1588-2780 SN - 1417-2097 VL - 271 IS - 1 SP - 251 EP - 253 PB - Elsevier Sequoia CY - Lausanne AN - OPUS4-14568 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Görner, Wolf A1 - Alber, D. A1 - Berger, Achim A1 - Haase, Oskar A1 - Monse, G. A1 - Segebade, Christian T1 - BEAMGAA - A chance for high precision analysis of big samples N2 - In activation analysis of traces in small samples, the non-equivalence of the activating radiation doses of sample and calibration material gives rise to sometimes tolerable systematic errors. Conversely, analysis of major components usually demands high trueness and precision. To meet this, beam geometry activation analysis (BEAMGAA) procedures have been developed for instrumental photon (IPAA) and neutron activation analysis (INAA) in which the activating neutron/photon beam exhibits broad, flat-topped characteristics. This results in a very low lateral activating flux gradient compared to known radiation facilities, however, at significantly lower flux density. The axial flux gradient can be accounted for by a monitor-sample-monitor assembly. As a first approach, major components were determined in high purity substances as well as selenium in a cattle fodder additive. T2 - 6th International Conference "Methods and Applications of Radioanalytical Chemistry" CY - Kailua-Kona, HI, United States of America DA - 2003-04-07 KW - Beam geometry activation analysis KW - Flux gradients KW - Measurement regime KW - Representativity KW - Big samples PY - 2005 DO - https://doi.org/10.1007/s10967-005-0660-6 SN - 0236-5731 SN - 1588-2780 SN - 1417-2097 VL - 263 IS - 3 SP - 791 EP - 796 PB - Elsevier Sequoia CY - Lausanne AN - OPUS4-6907 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Winkler, T. A1 - Hoenig, E. A1 - Huber, G. A1 - Janssen, R. A1 - Fritsch, D. A1 - Gildenhaar, Renate A1 - Berger, Georg A1 - Morlock, M.M. A1 - Schilling, A.F. T1 - Osteoclastic bioresorption of biomaterials: Two- and three-dimensional imaging and quantification N2 - Purpose: Bioresorbable materials have been developed in the hope that the body will replace them with newly formed tissue. The first step of this remodeling process in bone is the bioresorption of the material by osteoclasts. The aim of this study was to analyze osteoclastic resorption of biomaterials in vitro using the commonly used two-dimensional methods of light-microscopy (LM) and scanning electron microscopy (SEM) in comparison with infinite focus microscopy (IFM), a recently developed imaging method allowing for three-dimensional surface analysis. Methods: Human hematopoietic stem cells were cultivated in the presence of the cytokines M-CSF and RANK-L for 4 weeks directly on dentin and a calcium phosphate cement. Osteoclast development was surveyed with standard techniques. After removal of the cells, resorption was characterized and quantified by LM, SEM and IFM. Results: Osteoclast cultures on the biomaterials presented the typical osteoclast-specific markers. On dentin samples LM, SEM as well as IFM allowed for discrimination of resorption. Quantification of the resorbed area showed a linear correlation between the results (LM vs. SEM: r=0.996, p=0.004; SEM vs. IFM: r=0.989, p=0.011; IFM vs. LM: r=0.995). It was not possible to demarcate resorption pits on GB14 using LM or SEM. With IFM, resorption on GB14 could be visualized and quantified two- and three-dimensionally. KW - Biomaterial KW - Three-dimensional KW - IFM KW - Osteoclast KW - Dentin KW - Calcium phosphate PY - 2010 SN - 0391-3988 VL - 33 IS - 4 SP - 198 EP - 203 PB - Wichtig Ed. CY - Milano [u.a.] AN - OPUS4-21621 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Adel-Khattab, D. A1 - Giacomini, F. A1 - Gildenhaar, R. A1 - Berger, G. A1 - Gomes, Cynthia A1 - Linow, Ulf A1 - Hardt, M. A1 - Peleska, B. A1 - Günster, Jens A1 - Stiller, M. A1 - Houshmand, A. A1 - Ghaffar, K. A1 - Gamal, A. A1 - El-Mofty, M. A1 - Knabe, C. T1 - Development of a synthetic tissue engineered three- dimensional printed bioceramic-based bone graft with homogenously distributed osteoblasts and mineralizing bone matrix in vitro N2 - Over the last decade there have been increasing efforts to develop three-dimensional (3D) scaffolds for bone tissue Engineering from bioactive ceramics with 3D printing emerging as a promising technology. The overall objective of the present study was to generate a tissue engineered synthetic bone graft with homogenously distributed osteoblasts and mineralizing bone Matrix in vitro, thereby mimicking the advantageous properties of autogenous bone grafts and facilitating usage for reconstructing segmental discontinuity defects in vivo . To this end, 3D scaffolds were developed from a silica-containing calcium alkali orthophosphate, using, fi rst, a replica technique – the Schwartzwalder – Somers method – and, second, 3D printing, (i.e. rapid prototyping). The mechanical and physical scaffold properties and their potential to facilitate homogenous colonization by osteogenic cells and extracellular bone matrix formation throughout the porous scaffold architecture were examined. Osteoblastic cells were dynamically cultured for 7 days on both scaffold types with two different concentrations of 1.5 and 3 × 10⁹ cells/l. The amount of cells and bone matrix formed and osteogenic marker expression were evaluated using hard tissue histology, immunohistochemical and histomorphometric analysis. 3D-printed scaffolds (RPS) exhibited more micropores, greater compressive strength and silica release. RPS seeded with 3 × 10⁹ cells/l displayed greatest cell and extracellular Matrix formation, mineralization and osteocalcin expression. In conclusion, RPS displayed superior mechanical and biological properties and facilitated generating a tissue engineered synthetic bone graft in vitro, which mimics the advantageous properties of autogenous bone grafts, by containing homogenously distributed terminally differentiated osteoblasts and mineralizing bone matrix and therefore is suitable for subsequent in vivo implantation for regenerating segmental discontinuity bone defects. KW - Bone tissue engineering KW - Calcium alkali orthophosphate KW - Rapid prototyping KW - Scaffold KW - Mandible PY - 2017 DO - https://doi.org/10.1002/term.2362 SN - 1932-6254 SN - 1932-7005 VL - 12 IS - 1 SP - 44 EP - 58 PB - Wiley Online Library AN - OPUS4-40745 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Knabe, C. A1 - Stiller, M. A1 - Kampschulte, M. A1 - Wilbig, Janka A1 - Peleska, B. A1 - Günster, Jens A1 - Gildenhaar, R. A1 - Berger, G. A1 - Rack, A. A1 - Linow, U. A1 - Heiland, M. A1 - Rendenbach, C. A1 - Koerdt, S. A1 - Steffen, C. A1 - Houshmand, A. A1 - Xiang-Tischhauser, L. A1 - Adel-Khattab, D. T1 - A tissue engineered 3D printed calcium alkali phosphate bioceramic bone graft enables vascularization and regeneration of critical-size discontinuity bony defects in vivo N2 - Recently, efforts towards the development of patient-specific 3D printed scaffolds for bone tissue engineering from bioactive ceramics have continuously intensified. For reconstruction of segmental defects after subtotal mandibulectomy a suitable tissue engineered bioceramic bone graft needs to be endowed with homogenously distributed osteoblasts in order to mimic the advantageous features of vascularized autologous fibula grafts, which represent the standard of care, contain osteogenic cells and are transplanted with the respective blood vessel. Consequently, inducing vascularization early on is pivotal for bone tissue engineering. The current study explored an advanced bone tissue engineering approach combining an advanced 3D printing technique for bioactive resorbable ceramic scaffolds with a perfusion cell culture technique for pre-colonization with mesenchymal stem cells, and with an intrinsic angiogenesis technique for regenerating critical size, segmental discontinuity defects in vivo applying a rat model. To this end, the effect of differing Si-CAOP (silica containing calcium alkali orthophosphate) scaffold microarchitecture arising from 3D powder bed printing (RP) or the Schwarzwalder Somers (SSM) replica fabrication technique on vascularization and bone regeneration was analyzed in vivo. In 80 rats 6-mm segmental discontinuity defects were created in the left femur. KW - Additive Manufacturing KW - Bio active ceramic KW - In-vivo KW - Alcium alkali phosphate PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-584555 DO - https://doi.org/10.3389/fbioe.2023.1221314 SN - 2296-4185 VL - 11 SP - 1 EP - 20 PB - Frontiers SA CY - Lausanne AN - OPUS4-58455 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Reiche, I. A1 - Berger, Achim A1 - Bevers, H. A1 - Dupuis, G. A1 - Duval, A. A1 - Görner, Wolf A1 - Guicharnaud, H. A1 - Merchel, Silke A1 - Radtke, Martin A1 - Riederer, J. A1 - Riesemeier, Heinrich A1 - Roth, M. T1 - Spatially resolved SR-XRF analyses of complex drawings by the Holbein family and silverpoint drawings by Rembrandt KW - X-ray spectrometry KW - XRF KW - Röntgenfluoreszenzanalyse KW - RFA KW - Silverpoint drawing KW - Silberstiftzeichnung PY - 2005 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annualreport2004.pdf#page=491 SN - 0179-4159 SP - 491 EP - 493 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-7380 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -