TY - CONF A1 - Hernández-Gómez, R. A1 - Fernández-Vicente, T. A1 - Chamorro, C. R. T1 - Experimental determination of the density of different biomethane synthetic mixtures N2 - Experimental characterization of the thermodynamic behavior of multicomponent gas mixtures of accurately known composition with traceability to National Standard is of great importance for testing the current reference equation of state (EoS) for natural gases and related mixtures, GERG-2008. Natural gas composition may change considerably due to the diversity of origins, or the possibility to incorporate hydrogen, biomethane or other non-conventional energy gases. In this work, density measurements for three synthetic mixtures, representing two biomethane mixtures and a typical natural gas composition, are presented. Results are compared to the current reference EoS for natural gases and related mixtures, i.e., GERG-2008 and AGA8-DC92. T2 - The 11th Asian Thermophysical Properties Conference CY - Yokohama, Japan DA - 02.10.2016 KW - Density measurements KW - Gas mixtures KW - GERG-2008 equation of state PY - 2016 AN - OPUS4-37963 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hernández-Gómez, R. A1 - Chamorro, C. R. T1 - Experimental determination of the density of two synthetic natural gas-type mixtures N2 - Experimental characterization of the thermodynamic behavior of multicomponent gas mixtures of accurately known composition is of great importance for testing the current reference equation of state for natural gases and related mixtures, GERG-2008. Natural gas composition may change considerably due to the diversity of origins, or the possibility to incorporate hydrogen, biogas or other non-conventional energy gases. Thus, the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM) of the Bureau International des Poids et Mesures (BIPM) launched a key comparison on primary standard mixtures for natural gases of this particular characteristics. One mixture is a hydrogen-enriched natural gas mixture (13 components, x(H2) = 0.03) with low calorific value to facilitate support to power-to-gas applications, which often involve blending hydrogen with natural gas. The other mixture resembles a typical liquefied natural gas (“LNG”, 9 components) with high calorific value. T2 - 19th Symposium on Thermophysical Properties CY - Boulder, CO, USA DA - 21.06.2015 KW - GERG-2008 equation of state KW - Density KW - Natural gas-type mixtures KW - Hydrogen-enriched natural gas KW - Liquefied natural gas PY - 2015 AN - OPUS4-35942 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hernández-Gómez, R. A1 - Tuma, Dirk A1 - Villamañán, R. A1 - Chamorro, C. R. T1 - Accurate experimental (p, rho, T) values and virial coefficients for the (methane and helium) binary system N2 - This work provides accurate experimental (p, rho, T) values for three binary mixtures of methane with helium: (0.95 (amount-of-substance fraction) CH₄+ 0.05 He) and (0.90 CH₄+ 0.10 He) at temperatures of (240, 250, and 260) K and (0.50 CH₄+ 0.50 He) from (240 to 400) K. This work is a continuation of a previous one which reported accurate experimental (p, rho, T) values for the (0.95 CH₄+ 0.05 He) and the (0.90 CH₄+ 0.10 He) binary mixtures over the temperature range from (250 to 400) K. All density measurements were performed by using a single-sinker densimeter with magnetic suspension coupling at pressures up to 20 MPa. Experimental values were compared with the corresponding densities calculated from the GERG-2008 and the AGA8-DC92 equations of state, respectively. Deviations from the GERG-2008 are much larger than from the AGA8-DC92 (up to -6.5%). These deviations increase with decreasing temperature, with increasing pressure, and with increasing helium fraction. In contrast, deviations from the AGA8-DC92 are within the 0.5% band. The experimental values were also used to calculate the second and the third virial coefficients, B(T,x) and C(T,x), as well as the second interaction virial coefficient B12(T) for this mixture. KW - Binary mixture KW - Density KW - GERG-2008 equation of state KW - Virial coefficient PY - 2016 DO - https://doi.org/10.1016/j.jct.2016.05.024 SN - 0021-9614 SN - 1096-3626 VL - 101 SP - 168 EP - 179 PB - Elsevier Ltd. CY - London, UK AN - OPUS4-36811 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wang, P. A1 - Morales-Marquez, R. A1 - Cervas, G. A1 - Hernandez Medel, A. A1 - Ogayar, M. P. A1 - Jimenez de Aberasturi, D. A1 - de Isidro-Gomez, A. I. A1 - Torres-Padro, A. A1 - Palomares, F. J. A1 - Garcia-Orrit, S. A1 - Sousa, C. T. A1 - Espinosa, A. A1 - Telle, H. H. A1 - Ortgies, D. H. A1 - Vega-Mayoral, V. A1 - Cabanillas-Gonzalez, J. A1 - Rodriguez, E. M. A1 - Resch-Genger, Ute A1 - Wegner, Karl David A1 - Juarez, B. H. T1 - The role of temperature in the photoluminescence quantum yield (PLQY) of Ag2S-based nanocrystals N2 - Highly emissive Ag2S nanocrystals (NCs) passivated with a gradated shell incorporating Se and Zn were synthesized in air, and the temperature dependence of their photoluminescence quantum yield (PLQY) was quantified in both organic and aqueous media at B1200 nm. The relevance of this parameter, measured at physiological temperatures, is highlighted for applications that rely on the near infrared (NIR) photoluminescence of NCs, such as deep NIR imaging or luminescence nanothermometry. Hyperspectral NIR imaging shows that Ag2S-based NCs with a PLQY in organic media of about 10% are inefficient for imaging at 40 8C through 20 mm thick tissue with low laser irradiation power densities. In contrast, water-transferred Ag2S-based NCs with an initial PLQY of 2% in water exhibit improved robustness against temperature changes, enabling improved imaging performance. KW - Quantum dots KW - Ag2S KW - Fluorescence KW - Nanomaterial design KW - Advanced nanomaterials KW - Shortwave infrared (SWIR) KW - Temperature sensing PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-613877 DO - https://doi.org/10.1039/D4MH01016G SP - 1 EP - 11 PB - Royal Society of Chemistry (RSC) AN - OPUS4-61387 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reed, B. P. A1 - Cant, D.J.H. A1 - Spencer, S.J. A1 - Carmona-Carmona, A. J. A1 - Bushell, A. A1 - Herrara-Gómez, A. A1 - Kurokawa, A. A1 - Thissen, A. A1 - Thomas, A.G. A1 - Britton, A.J. A1 - Bernasik, A. A1 - Fuchs, A. A1 - Baddorf, A.P. A1 - Bock, B. A1 - Thellacker, B. A1 - Cheng, B. A1 - Castner, D.G. A1 - Morgan, D.J. A1 - Valley, D. A1 - Willneff, E.A. A1 - Smith, E.P. A1 - Nolot, E. A1 - Xie, F. A1 - Zorn, G. A1 - Smith, G.C. A1 - Yasukufu, H. A1 - Fenton, J.L. A1 - Chen, J. A1 - Counsell, J.D.P. A1 - Radnik, Jörg A1 - Gaskell, K.J. A1 - Artyushkova, K. A1 - Yang, L. A1 - Zhang, L. A1 - Eguchi, M. A1 - Walker, M. A1 - Hajdyla, M. A1 - Marzec, M.M. A1 - Linford, M.R. A1 - Kubota, N. A1 - Cortazar-Martinez, O. A1 - Dietrich, P. A1 - Satoh, R. A1 - Schroeder, S.L.M. A1 - Avval, T.G. A1 - Nagatomi, T. A1 - Fernandez, V. A1 - Lake, W. A1 - Azuma, Y. A1 - Yoshikawa, Y. A1 - Compean-Gonzalez, C.L. A1 - Ceccone, G. A1 - Shard, A.G. T1 - ERRATUM: “Versailles project on advanced materials and standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene” [J. Vac. Sci. Technol. A 38, 063208 (2020)] N2 - The lead authors failed to name two collaborators as co-authors. The authors listed should include: Miss Claudia L. Compean-Gonzalez (ORCID: 0000-0002-2367-8450) and Dr. Giacomo Ceccone (ORCID: 0000-0003-4637-0771). These co-authors participated in VAMAS project A27, provided data that were analyzed and presented in this publication (and supporting information), and reviewed the manuscript before submission. KW - X-ray photoelectron spectroscopy KW - Transmission function KW - Low-density polyethylene PY - 2021 DO - https://doi.org/10.1116/6.0000907 VL - 39 IS - 2 SP - 027001 PB - American Vacuum Society AN - OPUS4-52380 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Merchel, S. A1 - Bremser, Wolfram A1 - Akhmadaliev, S. A1 - Arnold, M. A1 - Aumaître, G. A1 - Bourlès, D.L. A1 - Braucher, R. A1 - Caffee, M. A1 - Christl, M. A1 - Fifield, L.K. A1 - Finkel, R.C. A1 - Freeman, S.P.H.T. A1 - Ruiz-Gómez, A. A1 - Kubik, P.W. A1 - Martschini, M. A1 - Rood, D.H. A1 - Tims, S.G. A1 - Wallner, A. A1 - Wilcken, K. M. A1 - Xu, S. T1 - Quality assurance in accelerator mass spectrometry: results from an international round-robin exercise for 10Be N2 - The first international round-robin exercise for the measurement of the long-lived radionuclide 10Be has been conducted. Ten participating accelerator mass spectrometry (AMS) facilities have each measured three samples at the 10-12 to 10-14 10Be/9Be level. All results have been made traceable to the NIST SRM 4325 standard to avoid additional discrepancies that arise when different facilities use different calibration materials. Hence, the data concentrates on pure measurement distinctions. Multivariate statistical investigations have been performed to reveal a bias between facilities, i.e. two distinguished groups could be identified. Maximum discrepancies between two single facilities are in the range of 6–31% depending on the absolute 10Be/9Be value. These findings should be considered when comparing 10Be data produced at one AMS facility with that produced at another facility, which is e.g. often the case for in situ 10Be dating studies. Round-robin exercises are a very helpful tool as part of an overall quality assurance scheme to improve the accuracy, and not only the precision, of AMS data. KW - Accelerator mass spectrometry KW - Terrestrial cosmogenic nuclides (TCN) KW - Cosmogenic nuclides (TCN) KW - Cosmogenic nuclide exposure dating KW - Calibration PY - 2012 DO - https://doi.org/10.1016/j.nimb.2012.07.038 SN - 0168-583X SN - 1872-9584 VL - 289 SP - 68 EP - 73 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-26772 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hernández-Gómez, R. A1 - Tuma, Dirk A1 - Villamanan, M.A. A1 - Mondéjar, M.E. A1 - Chamorro, C.R. T1 - Accurate thermodynamic characterization of a synthetic coal mine methane mixture N2 - In the last few years, coal mine methane (CMM) has gained significance as a potential non-conventional gas fuel. The progressive depletion of common fossil fuels reserves and, on the other hand, the positive estimates of CMM resources as a by-product of mining promote this fuel gas as a promising alternative fuel. The increasing importance of its exploitation makes it necessary to check the capability of the present-day models and equations of state for natural gas to predict the thermophysical properties of gases with a considerably different composition, like CMM. In this work, accurate density measurements of a synthetic CMM mixture are reported in the temperature range from (250 to 400) K and pressures up to 15 MPa, as part of the research project EMRP ENG01 of the European Metrology Research Program for the characterization of non-conventional energy gases. Experimental data were compared with the densities calculated with the GERG-2008 equation of state. Relative deviations between experimental and estimated densities were within a 0.2% band at temperatures above 275 K, while data at 250 K as well as at 275 K and pressures above 10 MPa showed higher deviations. KW - Coal mine methane KW - Density measurements KW - Single sinker densimeter KW - GERG-2008 equation of state PY - 2014 DO - https://doi.org/10.1016/j.jct.2013.09.023 SN - 0021-9614 VL - 68 SP - 253 EP - 259 PB - Academic Press CY - London [u.a.] AN - OPUS4-29450 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reed, B. P. A1 - Cant, D.J.H. A1 - Spencer, J. A1 - Carmona-Carmona, A. J. A1 - Bushell, A. A1 - Herrara-Gómez, A. A1 - Kurokawa, A. A1 - Thissen, A. A1 - Thomas, A.G. A1 - Britton, A.J. A1 - Bernasik, A. A1 - Fuchs, A. A1 - Baddorf, A. P. A1 - Bock, B. A1 - Thellacker, B. A1 - Cheng, B. A1 - Castner, D.G. A1 - Morgan, D.J. A1 - Valley, D. A1 - Willneff, E.A. A1 - Smith, E.F. A1 - Nolot, E. A1 - Xie, F. A1 - Zorn, G. A1 - Smith, G.C. A1 - Yasukufu, H. A1 - Fenton, J. L. A1 - Chen, J. A1 - Counsell, J..D.P. A1 - Radnik, Jörg A1 - Gaskell, K.J. A1 - Artyushkova, K. A1 - Yang, L. A1 - Zhang, L. A1 - Eguchi, M. A1 - Walker, M. A1 - Hajdyla, M. A1 - Marzec, M.M. A1 - Linford, M.R. A1 - Kubota, N. A1 - Cartazar-Martínez, O. A1 - Dietrich, P. A1 - Satoh, R. A1 - Schroeder, S.L.M. A1 - Avval, T.G. A1 - Nagatomi, T. A1 - Fernandez, V. A1 - Lake, W. A1 - Azuma, Y. A1 - Yoshikawa, Y. A1 - Shard, A.G. T1 - Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene N2 - We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ∼3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ∼5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ∼4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. We also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration. KW - X-ray photoelectron spectroscopy KW - Transmission function KW - Intensity scale calibration KW - Reference spectra KW - Low-density polyethylene (LDPE) PY - 2020 DO - https://doi.org/10.1116/6.0000577 VL - 38 IS - 6 SP - 063208 AN - OPUS4-51655 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -