TY - RPRT A1 - Arndt, Detlef A1 - Borchardt, Kerstin A1 - Croy, F. A1 - Geyer, Emil A1 - Henschen, Joachim A1 - Maierhofer, Christiane A1 - Niedack, Marianne A1 - Rudolphi, Michael A1 - Schaurich, Dieter A1 - Weise, Frank A1 - Wiggenhauser, Herbert T1 - Anwendung u. Kombination zerstörungsfreier Prüfverfahren zur Bestimmung der Mauerwerksfeuchte im Deutschen Dom N2 - Am Deutschen Dom wurden Mikrowellenabsorptionsmessungen, Radar und Infarot- Thermographie als moderne zerstörungsfreie Prüfverfahren der Feuchtemessung in Mauerwerk erprobt. Ergänzende numerische Simulationsrechnungen des gekoppelten Wärme- und Feuchtetransports sollen bei der Auswahl von Trockenlegungskonzepten helfen. T3 - BAM Forschungsberichtreihe - 200 PY - 1994 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-2509 SN - 978-3-89429-423-X SN - 0938-5533 VL - 200 SP - 1 EP - 84 PB - Wirtschaftsverlag NW CY - Bremerhaven AN - OPUS4-250 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Weise, Frank A1 - Henschen, Joachim A1 - Hoffmann, Dirk A1 - Niedack-Nad, Marianne A1 - Rudolph, Michael A1 - Schaurich, Dieter ED - Friese, P. ED - Venzmer, H. T1 - Anwendung und Kombination moderner Untersuchungsverfahren zur Beurteilung des Feuchtehaushalts im Zeughaus Berlin T2 - Vorträge anläßlich der 7. Hanseatischen Sanierungstage CY - Kühlungsborn, Deutschland DA - 1996-11-07 KW - Bauteil KW - Feuchtegehalt KW - Mikrowelle KW - Zeughaus, Berlin PY - 1996 SN - 3-345-00629-4 IS - 7 SP - 182 EP - 207 PB - Verlag für Bauwesen CY - Berlin AN - OPUS4-643 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Weise, Frank A1 - Niedack-Nad, Marianne A1 - Henschen, Joachim A1 - Hoffmann, Dirk A1 - Rudolph, Michael A1 - Schaurich, Dieter ED - Riederer, J. T1 - Complex investigations of the moisture balance in structural members made of natural stone - a case study of the Berlin Zeugnis T2 - 8th International Congress on Deterioration and Conservation of Stone CY - Berlin, Germany DA - 1996-09-30 KW - Stein KW - Naturstein KW - Wasserhaushalt KW - Feuchtigkeit KW - Zeughaus, Berlin PY - 1996 SN - 3-00-000779-2 VL - 1 SP - 441 EP - 451 CY - Berlin AN - OPUS4-647 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Weise, Frank A1 - Schaurich, Dieter ED - Venzmer, H. T1 - Langzeituntersuchungen zum Austrocknungsverhalten des Hauptgesimses am Zeughaus Berlin T2 - 2. Altbau-Symposium anlässlich der Bautec 2002 CY - Berlin, Deutschland DA - 2002-02-08 PY - 2002 SN - 3-345-00802-5 N1 - Serientitel: Altbauinstandsetzung – Series title: Altbauinstandsetzung IS - 4 SP - 45 EP - 63 PB - Verl. Bauwesen CY - Berlin AN - OPUS4-1838 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weise, Frank A1 - Schaurich, Dieter T1 - Long-Term Investigations on Drying out of the Main Cornice of the Berlin Zeughaus T2 - 11. Bauklimatisches Symposium ; 11th Symposium of Building Physics CY - Dresden, Germany DA - 2002-09-26 PY - 2002 SP - 722 EP - 737 PB - TU CY - Dresden AN - OPUS4-1839 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Weise, Frank A1 - Schaurich, Dieter T1 - A novel combination of NDT-methods for assessment of moisture conditions in structural members - a case study of the Berlin Zeughaus N2 - The moisture condition of solid brick and sandstone walls of historic buildings may be examined and monitored non-destructively and effectively by means of a novel combination of test methods which provide useful information on planning and monitoring rehabilitation and maintenance measures. Results are presented of an interdisciplinary research project of BAM on the moisture balance in the main cornice area of the Berlin Zeughaus. The main part of the investigations was carried out in 1994 and 1995. The quality of the prognosticated drying out process has been verified annually by means of measurements up to 2002. The depth-resolved local moisture determinations were accomplished with a microwave method developed by BAM. The moisture profiles revealed excessive moisture in the building element and reflected the slow drying process. Additionally, endoscopic examinations and chemical and physical analyses of miniature samples were carried out as well to help interpret the results. Hygrothermal data could be calculated from the quasi non-destructive tests and the parameters determined by the laboratory tests. Based on the 1995 measured moisture profile in the building element, the predicted simulation calculation indicated that a relatively long drying out process must be anticipated. Therefore the planned waterproofing sealing can at the earliest be applied to the surface of the building element in 2005. The good correlation of predicted and measured moisture profiles of the past years demonstrates the high quality of the new combination of test methods. T2 - 6th International Symposium Non-Destructive Testing in Civil Engineering (NDT-CE) CY - Berlin, Germany DA - 2003-09-16 PY - 2003 UR - http://www.ndt.net/article/ndtce03/papers/v034/v034.htm SN - 3-931381-49-8 SP - 1 EP - 10(?) PB - DGZfP CY - Berlin AN - OPUS4-2599 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Weise, Frank A1 - Schaurich, Dieter ED - Forde, M. C. T1 - A novel combination of NDT-methods for assessment of moisture conditions of Masonry - a case study of the Berlin Zeughaus T2 - 10th Structural Faults + Repair Conference CY - London, England, UK DA - 2003-07-01 KW - Microwave method KW - Endoscopy KW - Non-destructive technique (NDT) KW - Numerical hygrothermic simulations KW - Masonry PY - 2003 SN - 0-947644-53-9 PB - Engineering Technics Press CY - Edinburgh AN - OPUS4-2762 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Weise, Frank A1 - Schaurich, Dieter ED - Patitz, G. T1 - Langzeituntersuchungen zum Austrocknungsverhalten des Hauptgesimses am Zeughaus Berlin KW - Baudenkmäler KW - Feuchteuntersuchung KW - Zerstörungsfreie Prüfung KW - Mikrowellenverfahren KW - Hygrothermische Simulation PY - 2004 SN - 3-8167-6443-6 N1 - Serientitel: Monudocthema – Series title: Monudocthema IS - 1 SP - 179 EP - 197 PB - Fraunhofer-IRB-Verl. CY - Stuttgart AN - OPUS4-4824 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -