TY - RPRT A1 - Block, S. A1 - Boß, K.-H. A1 - Frobese, D.-H. A1 - Pape, H. A1 - Gösslinghoff, L. A1 - Grossepieper, T. A1 - Kasper, R. A1 - Kirchner, W. A1 - Kollmann, P. A1 - Kröger, P. A1 - Ringlstetter, P. A1 - Kuska, T. A1 - Mattejat, K. A1 - Niehüser, H. A1 - Pfeiffer, F. A1 - Pötzsch, Klaus-Michael A1 - Jochems, Frank A1 - Schäfer, H. A1 - Vogt, W. A1 - Zankl, C. A1 - Ludzay, J. T1 - Empfehlungen zur Vermeidung von Überdrücken an Tankfahrzeugen bei Untenbefüllung KW - Untenbefüllung KW - Tankfahrzeuge KW - Überdruck KW - Mineralöl KW - Sicherheitsventile PY - 2012 VL - 727 IS - 3 SP - 1-4, Anl. 1-3 AN - OPUS4-27921 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pauw, Brian Richard A1 - Smales, Glen Jacob A1 - Anker, A. S. A1 - Annadurai, V. A1 - Balazs, D. M. A1 - Bienert, Ralf A1 - Bouwman, W. G. A1 - Breßler, Ingo A1 - Breternitz, J. A1 - Brok, E. S. A1 - Bryant, G. A1 - Clulow, A. J. A1 - Crater, E. R. A1 - De Geuser, F. A1 - Del Giudice, A. A1 - Deumer, J. A1 - Disch, S. A1 - Dutt, S. A1 - Frank, K. A1 - Fratini, E. A1 - Garcia, P. R. A. F. A1 - Gilbert, E. P. A1 - Hahn, Marc Benjamin A1 - Hallett, J. A1 - Hohenschutz, M. A1 - Hollamby, M. A1 - Huband, S. A1 - Ilavsky, J. A1 - Jochum, J. K. A1 - Juelsholt, M. A1 - Mansel, B. W. A1 - Penttilä, P. A1 - Pittkowski, R. K. A1 - Portale, G. A1 - Pozzo, L. D. A1 - Rochels, L. A1 - Rosalie, Julian M. A1 - Saloga, Patrick E. J. A1 - Seibt, S. A1 - Smith, A. J. A1 - Smith, G. N. A1 - Spiering, G. A. A1 - Stawski, Tomasz M. A1 - Taché, O. A1 - Thünemann, Andreas A1 - Toth, K. A1 - Whitten, A. E. A1 - Wuttke, J. T1 - The human factor - Results of a small-angle scattering data analysis round robin N2 - A round-robin study has been carried out to estimate the impact of the human element in small-angle scattering data analysis. Four corrected datasets were provided to participants ready for analysis. All datasets were measured on samples containing spherical scatterers, with two datasets in dilute dispersions and two from powders. Most of the 46 participants correctly identified the number of populations in the dilute dispersions, with half of the population mean entries within 1.5% and half of the population width entries within 40%. Due to the added complexity of the structure factor, far fewer people submitted answers on the powder datasets. For those that did, half of the entries for the means and widths were within 44 and 86%, respectively. This round-robin experiment highlights several causes for the discrepancies, for which solutions are proposed. KW - Round Robin KW - Data analysis KW - Small-angle scattering KW - Nanomaterials KW - Interlaboratory comparability KW - Nanostructure quantification KW - Methodology KW - MOUSE PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-587091 DO - https://doi.org/10.1107/S1600576723008324 SN - 1600-5767 VL - 56 IS - 6 SP - 1618 EP - 1629 PB - Wiley-Blackwell CY - Oxford AN - OPUS4-58709 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - INPR A1 - Pauw, Brian Richard A1 - Smales, Glen Jacob A1 - Anker, A. S. A1 - Balazs, D. M. A1 - Beyer, F. L. A1 - Bienert, Ralf A1 - Bouwman, W. G. A1 - Breßler, Ingo A1 - Breternitz, J. A1 - Brok, E. S. A1 - Bryant, G. A1 - Clulow, A. J. A1 - Crater, E. R. A1 - De Geuser, F. A1 - Giudice, A. D. A1 - Deumer, J. A1 - Disch, S. A1 - Dutt, S. A1 - Frank, K. A1 - Fratini, E. A1 - Gilbert, E. P. A1 - Hahn, Marc Benjamin A1 - Hallett, J. A1 - Hohenschutz, Max A1 - Hollamby, M. J. A1 - Huband, S. A1 - Ilavsky, J. A1 - Jochum, J. K. A1 - Juelsholt, M. A1 - Mansel, B. W. A1 - Penttilä, P. A1 - Pittkowski, R. K. A1 - Portale, G. A1 - Pozzo, L. D. A1 - Ricardo de Abreu Furtado Garcia, P. A1 - Rochels, L. A1 - Rosalie, Julian M. A1 - Saloga, P. E. J. A1 - Seibt, S. A1 - Smith, A. J. A1 - Smith, G. N. A1 - Annadurai, V. A1 - Spiering, G. A. A1 - Stawski, Tomasz A1 - Taché, O. A1 - Thünemann, Andreas A1 - Toth, K. A1 - Whitten, A. E. A1 - Wuttke, J. T1 - The human factor - Results of a small-angle scattering data analysis round robin N2 - A Round Robin study has been carried out to estimate the impact of the human element in small-angle scattering data analysis. Four corrected datasets were provided to participants ready for analysis. All datasets were measured on samples containing spherical scatterers, with two datasets in dilute dispersions, and two from powders. Most of the 46 participants correctly identified the number of populations in the dilute dispersions, with half of the population mean entries within 1.5 % and half of the population width entries within 40 %, respectively. Due to the added complexity of the structure factor, much fewer people submitted answers on the powder datasets. For those that did, half of the entries for the means and widths were within 44 % and 86 % respectively. This Round Robin experiment highlights several causes for the discrepancies, for which solutions are proposed. KW - Round robin KW - Sall-angle scattering KW - Nanostructure quantification KW - Nanostructure KW - SAXS KW - MOUSE KW - X-ray scattering KW - Size distribution KW - Nanoparticles PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-571342 DO - https://doi.org/10.48550/arXiv.2303.03772 SP - 1 EP - 23 PB - Cornell University CY - Ithaca, NY AN - OPUS4-57134 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hamann, F. A1 - Brehm, Robert A1 - Pauli, Jutta A1 - Grabolle, Markus A1 - Frank, W. A1 - Kaiser, W.A. A1 - Fischer, D. A1 - Resch-Genger, Ute A1 - Hilger, I. T1 - Controlled modulation of serum protein binding and biodistribution of asymmetric cyanine dyes by variation of the number of sulfonate groups N2 - To assess the suitability of asymmetric cyanine dyes for in vivo fluoro-optical molecular imaging, a comprehensive study on the influence of the number of negatively charged sulfonate groups governing the hydrophilicity of the DY-67x family of asymmetric cyanines was performed. Special attention was devoted to the plasma protein binding capacity and related pharmacokinetic properties. Four members of the DY-67x cyanine family composed of the same main chromophore, but substituted with a sequentially increasing number of sulfonate groups (n = 1−4; DY-675, DY-676, DY-677, DY-678, respectively), were incubated with plasma proteins dissolved in phosphate-buffered saline. Protein binding was assessed by absorption spectroscopy, gel electrophoresis, ultrafiltration, and dialysis. Distribution of dye in organs was studied by intraveneous injection of 62 nmol dye/kg body weight into mice (n = 12; up to 180 minutes postinjection) using whole-body near-infrared fluorescence imaging. Spectroscopic studies, gel electrophoresis, and dialysis demonstrated reduced protein binding with increasing number of sulfonate groups. The bovine serum albumin binding constant of the most hydrophobic dye, DY-675, is 18 times higher than that of the most hydrophilic fluorophore, DY-678. In vivo biodistribution analysis underlined a considerable influence of dye hydrophilicity on biodistribution and excretion pathways, with the more hydrophobic dyes, DY-675 and DY-676, accumulating in the liver, followed by strong fluorescence signals in bile and gut owing to accumulation in feces and comparatively hydrophilic DY-678-COOH accumulating in the bladder. Our results demonstrate the possibility of selectively controlling dye-protein interactions and, thus, biodistribution and excretion pathways via proper choice of the fluorophore's substitution pattern. This underlines the importance of structure-property relationships for fluorescent labels. Moreover, our data could provide the basis for the rationalization of future contrast agent developments. PY - 2011 DO - https://doi.org/10.2310/7290.2011.00005 SN - 1535-3508 SN - 1536-0121 VL - 10 IS - 4 SP - 258 EP - 269 PB - Decker CY - Hamilton, Ont. AN - OPUS4-24311 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Marlow, Frank A1 - Dong, W. A1 - Hoffmann, Katrin A1 - Loerke, J. ED - Schüth, F. T1 - Optically and electronically functional materials PY - 2002 SN - 3-527-30246-8 SP - 3029 EP - 3063 PB - Wiley-VCH CY - Weinheim AN - OPUS4-1751 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Habel, Wolfgang A1 - Hofmann, Detlef A1 - Basedau, Frank A1 - Brandes, Klaus A1 - Barner, Andreas A1 - Crail, S. A1 - Reichel, D. A1 - Schreiner, U. A1 - Ecke, W. ED - Inaudi, D. T1 - Strain monitoring of a newly developed precast concrete track for high speed railway traffic using embedded fiber-optic sensors KW - Railway track system KW - Bonding behaviour KW - Fiber-optic sensor KW - Concrete composites PY - 2002 SN - 0-8194-4442-1 SN - 1605-7422 N1 - Serientitel: SPIE proceedings series – Series title: SPIE proceedings series IS - 4694 SP - 259 EP - 264 PB - SPIE CY - Bellingham, Wash. AN - OPUS4-1457 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Hasche, K. A1 - Ulm, G. A1 - Herrmann, K. A1 - Krumrey, M. A1 - Ade, G. A1 - Sümpel, J. A1 - Busch, I. A1 - Thomsen-Schmidt, P. A1 - Schädlich, S. A1 - Schindler, A. A1 - Frank, W. A1 - Procop, Mathias A1 - Beck, Uwe T1 - About the calibration of thickness standards on the nanometer scale T2 - 3rd International EUSPEN conference ; 3rd International conference. European Society for Precision Engineering and Nanotechnology ; 4th General meeting. European Society for Precision Engineering and Nanotechnology CY - Eindhoven, The Netherlands DA - 2002-05-26 PY - 2002 SN - 90-386-2883-8 SP - 1 EP - 5 CY - Eindhoven AN - OPUS4-2283 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hasche, K. A1 - Herrmann, K. A1 - Thomsen-Schmidt, P. A1 - Krumrey, M. A1 - Ulm, G. A1 - Ade, G. A1 - Pohlenz, F. A1 - Stümpel, J. A1 - Busch, I. A1 - Schädlich, S. A1 - Frank, W. A1 - Hirsch, D. A1 - Schindler, A. A1 - Procop, Mathias A1 - Beck, Uwe T1 - Ein Beitrag zu kalibrierten Nanometerschichten für unterschiedliche Anwendungsbereiche N2 - Nanotechnologien werden gegenwärtig als leistungsfähige Oberflächentechniken in erheblichem Umfange industriell genutzt. Dabei spielen dünne Schichten und deren Kenndaten eine wesentliche Rolle, z.B. als Röntgenspiegel oder optische und magnetooptische Datenträger. Die Schichtdicke zählt hierbei zu den technologisch wichtigen Parametern. Abgeleitet von Anwenderinteressen, werden für die Röntgenreflektometrie (XRR bzw. GIXR), Elektronenstrahl-Mikroanalyse (EPMA) und Röntgenfluoreszenzanalyse (XRF) einerseits und die Ellipsometrie andererseits zugeschnittene Schichtdickenmaßverkörperungen (SDM) entwickelt, gefertigt und untersucht. Das Ziel ist die Bereitstellung praxistauglicher, kalibrierter SDM, im weiteren Schichtdickennormale (SDN) genannt. SDN sind Maßverkörperungen, für die der Schichtdickenwert mit einer definierten Messunsicherheit bekannt und auf ein metrologisch anerkanntes Längennormal zurückgeführt ist. Berichtet wird über die Herstellung und messtechnische Charakterisierung der beiden spezifischen Varianten von Maßverkörperungen. T2 - 47. Internationales Wissenschaftliches Kolloquium. Technische Universität Ilmenau ; Herbstkonferenz der Gesellschaft für Arbeitswissenschaft ; 6. Workshop Multimedia für Bildung und Wirtschaft CY - Ilmenau, Deutschland DA - 2002-09-23 PY - 2002 UR - http://publica.fraunhofer.de/documents/N-14872.html VL - 47 SP - 568 EP - 569 PB - Techn. Univ. CY - Ilmenau AN - OPUS4-2284 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Koenders, L. A1 - Hasche, K. A1 - Ulm, G. A1 - Krumrey, M. A1 - Ade, G. A1 - Stümpel, J. A1 - Busch, I. A1 - Thomsen-Schmidt, P. A1 - Schädlich, S. A1 - Schindler, A. A1 - Frank, W. A1 - Beck, Uwe A1 - Procop, Mathias T1 - Über die metrologische Charakterisierung von Schichtdicken Standards im Nanometerbereich T2 - 12th Applied Surface Analysis Workshop ; AOFA 12 CY - --- DA - 2002-09-15 PY - 2002 AN - OPUS4-2285 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Krause, Martin A1 - Müller, W. A1 - Crail, S. T1 - Zerstörungsfreie Risscharakterisierung in Betonbauteilen mit Ultraschall N2 - Die Risstiefenbestimmung in Festen Fahrbahnen ist hinsichtlich der Dauerhaftigkeit der Konstruktion von wesentlichem Interesse. Im Rahmen eines gemeinsamen Forschungsvorhabens mit der DB AG wurden aus der Literatur bekannte Ansätze bewertet und darauf aufbauend ein Verfahren zur bildgebenden Rissdarstellung entwickelt. Rissüberbrückende Bewehrung sowie Kontaktstellen zwischen den Rissflanken wirken als Schallbrücken und erschweren die Risscharakterisierung, wie bei einem Einsatz an einer Betriebserprobungsstrecke festgestellt wurde. Ein aus der Literatur bekanntes Verfahren der einfachen Laufzeitmessung erwies sich für die Tiefenbestimmung von realen verunreinigten Rissen als ungeeignet. T2 - Fachtagung Bauwerksdiagnose - Praktische Anwendungen Zerstörungsfreier Prüfungen CY - Leipzig, Germany DA - 25.10.2001 PY - 2001 VL - 76-CD SP - 1 EP - 10 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-1188 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Krause, Martin A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Streicher, Doreen A1 - Müller, W. T1 - Ultrasonic Imaging of Concrete Elements - State of the Art Using 2D Synthetic Aperture N2 - Since several years ultrasonic imaging techniques are used for testing concrete elements. Combined with a reconstruction calculation they lead to an acoustic imaging of scatterers and reflectors from the inside of the concrete element. For several testing problems it is an advantage to use a two dimensional synthetic aperture and to combine it with a three-dimensional reconstruction calculation (3D-SAFT, Synthetic Aperture Focussing Technique). This enables the analysis of the tested volume by means of B-scans in two directions and C-scans (projections parallel to the surface), respectively. Using the 2D-scanning technique, especially the disturbing influence of the reinforcing rebars can be minimised. In this contribution the state of the art of this method is demonstrated and analysed. Examples of the application are presented, concerning Localisation of honeycombing and compaction faults Characterisation of cracks (especially measuring the crack depth) Investigation of tendon ducts The results presented are obtained in the frame of a research initiative Non-destructive Evaluation of Concrete Structures Using Acoustic and Electromagnetic Echo-Methods supported by the German Science Council (FOR 384 of DFG, Deutsche Forschungsgemeinschaft). The methods are assessed and improved in cooperation with the partners participating in the project. T2 - 6th International Symposium Non-Destructive Testing in Civil Engineering (NDT-CE) CY - Berlin, Germany DA - 2003-09-16 PY - 2003 UR - http://www.ndt.net/article/ndtce03/papers/v051/v051.htm SN - 3-931381-49-8 PB - DGZfP CY - Berlin AN - OPUS4-2606 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Krause, Martin A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Wiggenhauser, Herbert A1 - Müller, W. A1 - Schmitz, V. T1 - Ultrasonic imaging of concrete members using an array system KW - Ultrasonic echo KW - Array technique KW - SAFT (Synthetic Aperture Focusing Technique) KW - Tunnels KW - Reinforced concrete KW - Prestressing ducts PY - 2001 SN - 0963-8695 VL - 34 SP - 403 EP - 408 PB - Butterworth-Heinemann CY - Oxford AN - OPUS4-1082 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Procop, Mathias A1 - Radtke, Martin A1 - Krumrey, M. A1 - Hasche, K. A1 - Schädlich, S. A1 - Frank, W. T1 - Electron probe microanalysis (EPMA) measurement of thin-film thickness in the nanometre range N2 - The thickness of thin films of platinum and nickel on fused silica and silicon substrates has been determined by EPMA using the commercial software STRATAGEM for calculation of film thickness. Film thickness ranged in the order 10 nm. An attempt was made to estimate the confidence range of the method by comparison with results from other methods of analysis. The data show that in addition to the uncertainty of the spectral intensity measurement and the complicated fitting routine, systematic deviation caused by the underlying model should be added. The scattering in the results from other methods does not enable specification of a range of uncertainty, but deviations from the real thickness are estimated to be less than 20%. KW - Electron probe microanalysis KW - EPMA KW - Thin films KW - Thickness measurement KW - X-rays PY - 2002 DO - https://doi.org/10.1007/s00216-002-1514-5 SN - 1618-2642 SN - 1618-2650 VL - 374 SP - 631 EP - 634 PB - Springer CY - Berlin AN - OPUS4-7090 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kusche, Nadine A1 - Schukar, Vivien A1 - Hofmann, Detlef A1 - Basedau, Frank A1 - Habel, Wolfgang A1 - Woschitz, H. A1 - Lienhart, W. ED - Jaroszewicz, L.R. T1 - Field examples for optical fibre sensor condition diagnostics based on distributed fibre-optic strain sensing N2 - Fibre optic sensors for monitoring in safety-relevant structures have to be validated in order to proof their reliability under typical structural load conditions. The reliable use of optical fibre sensors depends strongly on an appropriate and qualitative application. Diagnostics of the physical condition of embedded and surface-applied fibre optic strain sensors are demonstrated on field examples. Distributed strain measurement based on Rayleigh backscattering is used to determine breakage of the fibre, interface adhesion problems and to identify application related strain transfer mechanisms. T2 - EWOFS 2013 - 5th European workshop on optical fibre sensors CY - Kraków, Poland DA - 19.05.2013 KW - Fibre Bragg grating KW - Rayleigh backscattering KW - Condition diagnostics KW - Strain KW - Strain transfer PY - 2013 SN - 978-0-81949-634-8 DO - https://doi.org/10.1117/12.2025567 SN - 0277-786X N1 - Serientitel: Proceedings of SPIE – Series title: Proceedings of SPIE VL - 8794 IS - Paper 8794 - 181 SP - 879433-1 EP - 879433-4 AN - OPUS4-28570 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Göbel, E. O. A1 - Hasche, K. A1 - Ulm, G. A1 - Krumrey, M. A1 - Ade, G. A1 - Stümpel, J. A1 - Herrmann, K. A1 - Koenders, L. A1 - Thomsen-Schmidt, P. A1 - Pohlenz, F. A1 - Xu, M. A1 - Dai, G. A1 - Hoffmann, K.-P. A1 - Busch, I. A1 - Frank, W. A1 - Procop, M. A1 - Beck, Uwe T1 - Kalibrierte Schichtdicken-Maßverkörperungen für Nanometerschichten, Teilvorhaben - Kalibrierung von Schichtdicken-Maßverkörperungen im Nanometerbereich - Abschlussbericht des BMBF Verbundvorhabens 13N7704 - 13N77041 KW - Schichtdicke KW - Nanometerbereich PY - 2003 UR - http://edok01.tib.uni-hannover.de/edoks/e01fb02/373214030.pdf SP - 1 EP - 131 PB - Physikalisch-Technische Bundesanstalt CY - Dresden AN - OPUS4-25428 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Thomsen-Schmidt, P. A1 - Hasche, K. A1 - Ulm, G. A1 - Herrmann, K. A1 - Krumrey, M. A1 - Ade, G. A1 - Stümpel, J. A1 - Busch, I. A1 - Schädlich, S. A1 - Schindler, A. A1 - Frank, W. A1 - Hirsch, D. A1 - Procop, Mathias A1 - Beck, Uwe T1 - Realisation and metrological characterisation of thickness standards below 100 nm N2 - High-accuracy film thickness measurements in the range below 100 nm can be made by various complex methods like spectral ellipsometry (SE), scanning force microscopy (SFM), grazing incidence X-ray reflectometry (GIXR), or X-ray fluorescence analysis (XRF). The measurement results achieved with these methods are based on different interactions between the film and the probe. A key question in nanotechnology is how to achieve consistent results on a level of uncertainty below one nanometre with different techniques. Two different types of thickness standards are realised. Metal film standards for X-ray techniques in the thickness range 10 to 50 nm are calibrated by GIXR with monochromatised synchrotron radiation of 8048 eV. The results obtained at four different facilities show excellent agreement. SiO2 on Si standards for SE and SFM in the thickness range 6 to 1000 nm are calibrated by GIXR with monochromatised synchrotron radiation of 1841 eV and with a metrological SFM. Consistent results within the combined uncertainties are obtained with the two methods. Surfaces and interfaces of both types of standards are additionally investigated by transmission electron microscopy (TEM). PY - 2004 DO - https://doi.org/10.1007/s00339-003-2273-7 SN - 0947-8396 VL - 78 IS - 5 SP - 645 EP - 649 PB - Springer CY - Berlin AN - OPUS4-17195 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brandt, S. A1 - Brozowski, Frank A1 - Horn, Wolfgang A1 - Plehn, W. A1 - Müller, B. T1 - Weiterentwicklung des Geruchsmessverfahrens für Bauprodukte (Teil II): Anwendung eines Adapters und vereinfachtes Bewertungsverfahren T1 - Further Development of the Odour Measurement Method for Building Products (Part II) N2 - Zur Weiterentwicklung der Probenpräsentation wurde ein Adapter entwickelt, der Emissionsprüfkammer und Bewertungstrichter miteinander verbindet und dadurch eine der direkten Messung vergleichbare Geruchsbewertung ermöglicht. Die analytischen Messungen zeigen, dass es kaum Unterschiede in der Zusammensetzung der Probenluft in der Kammer im Vergleich zum Probenbehälter gibt. Bei den olfaktorischen Messungen kam es jedoch bei der Bewertung der Probenluft mit Hilfe des Adapters zu Minderbefunden. Anschließende Untersuchungen zeigten, dass beim Ausschalten des Geräts Umgebungsluft über den Trichter in den Adapter strömt und zu einer Verdünnung der Probenluft führt. Um dies zu vermeiden, werden derzeit weitere Messungen durchgeführt. Eine weitere Versuchsreihe wurde durchgeführt, um den Messaufwand bei der Bewertung der empfundenen Intensität zu reduzieren. Die entwickelte „größer-oder-kleiner/gleich“ Abfrage kann hier hilfreich sein. Die Untersuchungen im Luftqualitätslabor und im Rahmen eines Ringversuches mit verschiedenen Laboren, zeigen, dass die Abfrage in fast allen Fällen zu den gleichen Ergebnissen führt, wie die normgerechte aber aufwendigere Ermittlung der empfundenen Intensität mithilfe des Vergleichsmaßstabes. N2 - For technical improvement of sample presentation an adapter was developed to connect the emission test chamber with the evaluation funnel and thus enabling a more direct measurement. The analytical measurements demonstrate that the air has a very similar composition sampled at the funnel or in the emission test chamber. The results of the olfactory measurements show overall that the intensities determined using the adapter are often reported as lower. Further investigations have shown that air backflow via the funnel into the sample container of the adapter may be the cause. This has to be avoided in future. Another experimental series was carried out to reduce the measurement effort of evaluation of perceived intensity. Here application of the developed ‘greater than, or less than/equal to’ survey could be helpful. The results of the measurements in the air quality lab and in the frame of a round robin test indicate, that the survey leads to the same evaluation as the more complex determination of perceived intensity with standard method. KW - Geruchsmessung KW - VOC-Emission KW - Bauprodukte KW - Bewertungsverfahren PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-549875 UR - http://www.gefahrstoffe.de SN - 0949-8036 SN - 1436-4891 VL - 82 IS - 3-4 SP - 83 EP - 89 PB - VDI Fachmedien CY - Düsseldorf AN - OPUS4-54987 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hea, Y. A1 - Esteban-Fernandez, Diego A1 - Neumann, B. A1 - Bergmann, U. A1 - Bierkandt, Frank A1 - Linscheid, M. W. T1 - Application of MeCAT-Click labeling for protein abundance characterization of E. coli after heat shock experiments N2 - In a proof of concept study, metal-coded affinity tags based on click chemistry (MeCAT-Click) were used to analyze the proteome of Escherichia coli (E. coli) in response to heat stress. This allows high labeling efficiency, high detection sensitivity, and multiplex capabilities, which are pivotal for its application to protein quantification. Two approaches are presented for relative quantification of differentially lanthanide-labeled proteins. The first approach uses isotope-labeling, where ESI-MS was utilized to quantify the differentially labeled proteins from different states of E. coli. With this approach, 14 proteins were found with changed abundance, among them five proteins upregulated. In the second approach, differentially labeled samples were separated by two dimensional gel electrophoresis (2 DE) and scanned by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Comparison of the signal intensities of the different lanthanides was used to quantify different sample states. Based on this information, ESI-MS was used to identify the proteins with different abundance. The sensitivity of LA-ICP-MS allowed us to find one upregulated protein that was nearly invisible by silver staining ("Probable replication endonuclease from retron EC67"). The advantage of this approach is to locate low abundant proteins with differential expression using LA-ICP-MS, which may be overlooked otherwise. Biological significance: This paper demonstrates the successful application of a novel metal labeling strategy to quantify the proteins from complex biological samples. In comparison with former metal labeling strategies, it reduces the steric hindrance and improves the labeling efficiency during the labeling process, which ensure its successful application. This methodology is compatible with both molecular and elemental mass spectrometry. ESI-MS/MS in combination with software-based search allows the identification and relative quantification of labeled proteins. In addition, LA-ICP-MS helps to locate the labeled proteins in 2-DE gels with superior detection capability, thus, target proteins with low abundance can be precisely followed. Its excellent sensitivity allows one to track the proteins of interest that are barely visible by silver staining. KW - Protein quantification KW - Heat shock response KW - Ln-MeCAT-Click labeling KW - nanoLC-ESI-MS/MS KW - 2-D electrophoresis KW - LA-ICP-MS PY - 2016 DO - https://doi.org/10.1016/j.jprot.2015.12.010 SN - 1874-3919 VL - 136 SP - 68 EP - 76 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-35837 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gers-Panther, C.F. A1 - Fischer, H. A1 - Nordmann, J. A1 - Seiler, T. A1 - Behnke, Thomas A1 - Würth, Christian A1 - Frank, W. A1 - Resch-Genger, Ute A1 - Müller, T.J.J. T1 - Four- and Five-Component Syntheses and Photophysical Properties of Emission Solvatochromic 3‑Aminovinylquinoxalines N2 - 3-Aminovinylquinoxalines are readily accessible from (hetero)aryl glyoxylic acids or heterocyclic π-nucleophiles by consecutive four- and fivecomponent syntheses in the sense of an activation-alkynylation-cyclocondensation-addition sequence or glyoxylation-alkynylation-cyclocondensation-addition sequence in good yields. The title compounds are highly fluorescent with pronounced emission solvatochromicity and protochromic fluorescence quenching. Time-resolved fluorescence spectroscopy furnishes radiative and nonradiative fluorescence decay rates in various solvent polarities. The electronic structure is corroborated by DFT and TD-DFT calculations rationalizing the observed spectroscopic effects. KW - Dye KW - Syntheseis KW - Spectroscopy PY - 2016 DO - https://doi.org/10.1021/acs.joc.6b02581 SN - 0022-3263 VL - 82 SP - 567 EP - 578 PB - ACS Publications AN - OPUS4-39211 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Werner, Jan A1 - Kutz, P. W. A1 - Otremba, Frank T1 - Testing of Small Scale Tank Prototypes under Cryogenic Conditions N2 - Climate change, CO2 reduction, resource efficiency are only 3 current keywords that describe the current industrial-economic situation. In order to influence climate change effectively, the conversion of supply systems with technically usable forms of energy must succeed in the next decade. The international network founded in Baku in 2015 bundles research activities in the broad field of energy supply and energy efficiency. Discuss current research approaches and results with scientists and experts from renowned universities and follow Azerbaijan's efforts to implement the energy revolution. T2 - Neseff 2020 CY - Online meeting DA - 28.09.2020 KW - Mud pumps KW - Mud circulation system KW - Pistons KW - Hydrostatic pressure KW - Friction wear KW - Ceramic liners KW - Tribology PY - 2020 SN - 978-3-940471-59-8 SP - 4 EP - 9 AN - OPUS4-52149 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Wöstmann, Jens A1 - Krause, Martin A1 - Maierhofer, Christiane A1 - Römer, A. A1 - Völkel, W. T1 - Untersuchungen zur zerstörungsfreien Bestimmung des Hohlraumgehaltes von Asphaltschichten T2 - DGZfP-Fachtagung Bauwerksdiagnose "Praktische Anwendungen Zerstörungsfreier Prüfungen" CY - Berlin, Deutschland DA - 2006-02-22 KW - Asphalt KW - Hohlraumgehalt KW - Zerstörungsfreie Prüfung KW - Ultraschallverfahren KW - Ultraschall-Rückstreuung KW - Radarverfahren PY - 2006 SN - 3-931381-71-4 SP - 1(?) EP - 9(?) PB - DGZfP CY - Berlin AN - OPUS4-12116 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Esteban-Fernández, D. A1 - Bierkandt, Frank A1 - Linscheid, M.W. T1 - MeCAT labeling for absolute quantification of intact proteins using labelspecific isotope dilution ICP-MS N2 - Sensitive, accurate and fast absolute quantification of intact proteins is reported using metal coded affinity tags (MeCATs) combined with gel electrophoresis (GE) separation, inductively coupled plasma mass spectrometry (ICP-MS) detection and label-specific isotope dilution analysis quantification. Two different approaches were investigated concerning the introduction of the sample into ICP-MS, mineralization of the gel and direct laser ablation (LA) of the spot. Three major advantages are remarkable in the proposed method. First, not only heteroatom-containing proteins but also all labeled proteins in the sample can be absolutely quantified preparing an isotopically enriched tracer. On the other hand, highly sensitive determination in the amol range can be performed, considerably reducing the analysis time due to the straightforward measurements by ICP-MS. Furthermore, the studied method allows accurate quantifications with different sample-to-spike ratios and using stock spikes stored for months. After the first characterization using standard proteins, human serum albumin (HSA) and transferrin (Tf) were determined in human serum to test the applicability of the method to biological samples. The results show satisfactory quantifications for the studied proteins despite the difference in concentration and the similarity in migration distances. PY - 2012 DO - https://doi.org/10.1039/c2ja30137g SN - 0267-9477 SN - 1364-5544 VL - 27 IS - 10 SP - 1701 EP - 1708 PB - Royal Society of Chemistry CY - London AN - OPUS4-27777 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Munter, L.M. A1 - Sieg, H. A1 - Bethge, T. A1 - Liebsch, F. A1 - Bierkandt, Frank A1 - Schleeger, M. A1 - Bittner, H.J. A1 - Heberle, J. A1 - Jakubowski, Norbert A1 - Hildebrand, P.W. A1 - Multhaup, G. T1 - Model peptides uncover the role of the beta-secretase transmembrane sequence in metal ion mediated oligomerization N2 - The β-secretase or β-site amyloid precursor protein cleaving enzyme 1 (BACE1) is the enzyme responsible for the formation of amyloid-β peptides, which have a major role in Alzheimer pathogenesis. BACE1 has a transmembrane sequence (TMS), which makes it unique among related proteases. We noticed that the BACE1 TMS contains an uncommon sulfur-rich motif. The sequence MxxxCxxxMxxxCxMxC spans the entire TMS, resembles metal ion binding motifs, and is highly conserved among homologues. We used a synthetic 31-mer model peptide comprising the TMS to study metal ion binding and oligomerization. Applying diverse biochemical and biophysical techniques, we detected dimer and trimer formation of the TMS peptide with copper ions. Replacement of the central Cys466 by Ala essentially abolished these effects. We show that the peptide undergoes a redox reaction with copper ions resulting in a disulfide bridge involving Cys466. Further, we find peptide trimerization that depends on the presence of monovalent copper ions and the sulfhydryl group of Cys466. We identified Cys466 as a key residue for metal ion chelation and to be the core of an oligomerization motif of the BACE1-TMS peptide. Our results demonstrate a novel metal ion controlled oligomerization of the BACE1 TMS, which could have an enormous therapeutic importance against Alzheimer disease. KW - Enzymes KW - Amyloid formation KW - Alzheimer disease KW - Copper PY - 2013 DO - https://doi.org/10.1021/ja410812r SN - 0002-7863 SN - 1520-5126 VL - 135 IS - 51 SP - 19354 EP - 19361 PB - American Chemical Society CY - Washington, DC AN - OPUS4-30543 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Julsing, M.K. A1 - Fichera, Mario Augusto A1 - Malz, Frank A1 - Ebbelaar, M. A1 - Bos, R. A1 - Woerdenbag, H. J. A1 - Quax, W.J. A1 - Kayser, O. T1 - Bioconversion of Mono- and Sesquiterpenoids by recombinant human Cytochrome P450 Monooxygenases N2 - Cytochrome P450 monooxygenases play an important role in the biosynthesis and metabolism of terpenoids. We explored the potential of recombinant human liver cytochrome P450 monooxygenases CYP1A2, CYP2C9, and CYP3A4, heterologously expressed in Escherichia coli, to convert mono- and sesquiterpenoids to human metabolites. This natural product group is a diverse class of secondary metabolites and includes several industrially and pharmaceutically interesting compounds. Incubation of cedrol with CYP3A4 resulted in a bioconversion of 74% (±8.9%) after 1 h of the unknown metabolites 2-hydroxycedrol and 4-hydroxycedrol, which have been structurally elucidated by 1H and 13C NMR and GC-MS. We conclude that recombinant human cytochrome P450 enzymes can be useful tools in a combinatorial biosynthesis strategy for the production of new natural products and for in vitro metabolization studies. KW - Cedrol KW - Cytochrome P450 KW - Drug metabolism KW - NMR KW - Terpenoids PY - 2008 DO - https://doi.org/10.1080/13880200802215487 SN - 1388-0209 SN - 1744-5116 VL - 46 IS - 10-11 SP - 710 EP - 718 PB - Informa Healthcare CY - New York, NY, USA AN - OPUS4-18912 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Becker, S. A1 - Beckmann, Jörg A1 - Braun, M.-T. A1 - Cojocari, O. A1 - Feige, V. A1 - Fischer, B. A1 - Friederich, F. A1 - Globisch, B. A1 - Hechtfischer, G. A1 - Hens, K. A1 - Hübers, H.-W. A1 - Jelonnek, J. A1 - Jonuscheit, J. A1 - Keil, A. A1 - Kleine-Ostmann, T. A1 - Marquardt, E. A1 - Mayr, M. A1 - Nickel, H.-U. A1 - Nüßler, D. A1 - Peichl, M. A1 - Peters, O. A1 - Schür, J. A1 - Sprenger, T. A1 - Steiger, A. A1 - van Frank, S. A1 - Vieweg, N. A1 - Wilk, R. ED - Jonuscheit, J. ED - Marquardt, E. T1 - Terahertzsysteme und Anwendungsfelder N2 - Der Frequenzbereich der Terahertzwellen liegt im elektromagnetischen Spektrum zwischen den Mikrowellen und dem infraroten Licht – also etwa im Bereich von 0,1 bis 10 Terahertz (THz). Der VDI-Statusreport „Terahertzsysteme und Anwendungen“ stellt die unterschiedlichen Konzepte für Terahertzsysteme vor und zeigt Anwendungsbeispiele, bei denen die Terahertztechnik erfolgreich eingesetzt wird. Umfangreiche Literaturangaben ermöglichen eine intensivere Beschäftigung mit allen Themen des VDI-Statusreports. KW - Terahertzsysteme PY - 2020 UR - https://www.vdi.de/ueber-uns/presse/publikationen/details/terahertzsysteme-und-anwendungsfelder SP - 1 EP - 44 PB - Verein Deutscher Ingenieure (VDI) CY - Düsseldorf AN - OPUS4-50556 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Becker, S. A1 - Beckmann, Jörg A1 - Cojocari, O. A1 - Feige, V. A1 - Fischer, B. A1 - Friederich, F. A1 - Globisch, B. A1 - Hechtfischer, G. A1 - Hens, K. A1 - Hübers, H.-W. A1 - Jelonnek, J. A1 - Jonuscheit, J. A1 - Keil, A. A1 - Kleine-Ostmann, T. A1 - Mayr, M. A1 - Nüßler, D. A1 - Peichl, M. A1 - Peters, O. A1 - Schür, J. A1 - Sprenger, T. A1 - Steiger, A. A1 - van Frank, S. A1 - Vieweg, N. A1 - Wilk, R. T1 - Terahertzsysteme - Zeitbereichsspektrometer (TDS-Systeme) N2 - Diese Richtlinie definiert Kenngrößen und Messverfahren, um Terahertzsysteme für die Zeitbereichsspektroskopie (TDS)zu spezifizieren. So können Hersteller ihre Systeme übereinstimmend beschreiben und Anwender einfach Systeme vergleichen. Systeme für die Terahertz-Zeitbereichsspektroskopie sind aktive Systeme und nutzen verschiedene Techniken sowohl zur Erzeugung als auch zur zeitaufgelösten Messung von breitbandigen Terahertzimpulsen. Die dazugehörigen Terahertzspektren und -Phasen werden nach einer zeitlichen Abtastung über eine Fourier-Transformation berechnet. In dieser Richtlinie wird ein Überblick über die Funktionsweisen von Zeitbereichsspektrometern gegeben, die eingesetzten Messverfahren näher erläutert sowie die benötigten Begriffe und Kenngrößen definiert. Die Richtlinie konzentriert sich dabei auf Systeme, die auf sogenannten Abtastmessverfahren (Sampling-Messverfahren) basieren. KW - TDS-Systeme PY - 2020 UR - https://www.vdi.de/5590 VL - VDI/VDE 5590 Blatt 2 SP - 1 EP - 22 PB - VDI-Verlag CY - Düsseldorf ET - Entwurf - Oktober 2020 AN - OPUS4-51947 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Beck, M. A1 - Becker, S. A1 - Beckmann, Jörg A1 - Cojocari, O. A1 - Feige, V. A1 - Fischer, B. A1 - Friederich, F. A1 - Globisch, B. A1 - Haupt, H. A1 - Hechtfischer, G. A1 - Hens, K. A1 - Hübers, H.-W. A1 - Jelonnek, J. A1 - Jonuscheit, J. A1 - Keil, A. A1 - Kleine-Ostmann, T. A1 - Nickel, H.-U. A1 - Peichl, M. A1 - Peters, O. A1 - Sprenger, T. A1 - Steiger, A. A1 - van Frank, S. A1 - Vieweg, N. A1 - Werner, M. A1 - Wilk, R. T1 - Terahertzsysteme - Anwendungsfelder und Systeme N2 - Die nicht ionisierende elektromagnetische Strahlung im Bereich von Terahertz-Frequenzen ermöglicht berührungslose und zerstörungsfreie Mess- und Prüftechnik in zahlreichen Bereichen. Nach ersten Anwendungen in der Astronomie und der Atmosphärenforschung wurden in letzter Zeit Anwendungsfelder in der Sicherheitstechnik, der Medizintechnik, der Nachrichtentechnik und der zerstörungsfreien Prozess- und Qualitätskontrolle erschlossen. Dielektrische Materialien wie Kunststoffe und Keramiken können von Terahertz-Wellen durchdrungen werden. Das ermöglicht Untersuchungen des Objektinneren ohne spezielle Schutzmaßnahmen, wie sie z.B. beim Röntgen notwendig sind. Die Richtlinie erleichtert die Verständigung zwischen Nutzern, Herstellern und dem Vertrieb von Terahertz-Systemen. In der Richtlinie werden bekannte Einsatzgebiete sowie die eingesetzten Verfahren und Funktionsprinzipien aufgeführt, um den Leser bei der Auswahlentscheidung zu unterstützen. Nach einer kurzen Einführung in die physikalischen Grundlagen und Hinweisen zur elektromagnetischen Verträglichkeit, zum Strahlenschutz und zur regulierten Frequenzvergabe werden die verschiedenen Geräteklassen von Terahertz-Systemen ausführlich vorgestellt. Die Richtlinie gibt Hinweise zur messtechnischen Charakterisierung von Terahertz-Wellen. Einsatzgebiete von Terahertz-Systemen, wie die zerstörungsfreie Prüfung, die Dicken- und Abstandsmessung, die Tomografie und die chemische Analytik, werden mit ihren spezifischen Eigenschaften im Detail beschrieben. Umfangreiche Literaturverweise vereinfachen eine vertiefte Beschäftigung mit den Themen der Richtlinie. Eine tabellarische Übersicht mit einer Zusammenfassung, welche Terahertz-Systeme für welche Anwendungsfelder eingesetzt werden können, vervollständigt die Richtlinie. KW - Terahertzsysteme KW - THz-Wellen PY - 2018 UR - https://www.vdi.de/5590 VL - VDI/VDE 5590 Blatt 2 SP - 1 EP - 27 PB - VDI-Verlag CY - Düsseldorf ET - Entwurf - November 2018 AN - OPUS4-46727 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -