TY - RPRT A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Kasche, J. A1 - Bitter, F. A1 - Müller, D. A1 - Müller, B. T1 - Environmental and Health Provisions for Building Products - Identification and evaluation of VOC emissions and odour exposure (Research Report 202 62 320 / UBA-FB 001002) T2 - UBA-Texte N2 - In this study 50 construction products were tested in emission test chambers according to the requirements of the AgBB-scheme: 7 acrylic and 6 silicone sealants, 6 paste-like synthetic resin plasters, 13 wood based products, 4 adhesives, 5 lacquers, 6 wall paints and 3 further construction products. VOC and odour emissions were tested on the 1st, 3rd, 10th, and 28th day. In addition to the VOC-measurements, a test procedure was developed to evaluate odour emission of construction products.This test is planned to be implemented into the AgBB-Scheme. A direct evaluation by a sensory panel in the emission test chamber was not possible. So the odour samples were collected in 300- litre tedlar bags which were evaluated later. Odour intensity of the samples was compared with different acetone concentrations. Within this study an interlaboratory comparison was conducted using the newly developed odour test method. Additionally, VVOC emissions, detection of carcinogenic compounds, repeatability of emission test chamber tests, and other issues are presented. This project has shown that construction products can be evaluated in accordance with the AgBB scheme. A sensory evaluation is intended to be introduced in the AgBB scheme. A method for this evaluation is described in this study. The test procedure should be enhanced and validated for practical utilisation. KW - Building products KW - Emissions KW - Odour KW - AgBB-Scheme KW - Chamber tests KW - Interlaboratory study KW - Construction products KW - Emission test chamber KW - Odour evaluation KW - VOC KW - VVOC KW - SVOC KW - Thermal desorption KW - GC/MS KW - GC-ODP KW - Odour standard of comparison KW - Gas sensor KW - Acrylic and silicone sealant KW - Wood-based product KW - Paints KW - Lacquers KW - Interlaboratory comparison PY - 2007 UR - http://www.umweltbundesamt.de/publikationen/environmental-health-provisions-for-building SN - 1862-4804 SN - 0722-186X IS - 21 SP - 1 EP - 381 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-15931 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, B. A1 - Dahms, A. A1 - Bitter, F. A1 - Wargocki, P. A1 - Olesen, B. A1 - Knudsen, H.N. A1 - Afshari, A. A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Müller, D. A1 - Airaksinen, M. A1 - Järnström, H. A1 - Tirkkonen, T. A1 - Witterseh, T. T1 - Material labelling: Combined material emission tests and sensory evaluations T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate, August 17-22, 2008, Copenhagen, Denmark (Proceedings) T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate CY - Copenhagen, Denmark DA - 2008-08-17 KW - Material labelling KW - Emission test KW - Sensory evaluation KW - Odour intensity KW - Acceptability PY - 2008 IS - Paper 1066 SP - 1 EP - 8 AN - OPUS4-18047 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Horn, Wolfgang A1 - Jann, Oliver A1 - Kasche, Johannes A1 - Bitter, F. A1 - Müller, D. A1 - Müller, B. T1 - Umwelt- und Gesundheitsanforderungen an Bauprodukte - Ermittlung und Bewertung der VOC-Emissionen und geruchlichen Belastungen (Forschungsbericht 20262320) T2 - UBA-Texte KW - Bauprodukte KW - Emissionen KW - Geruch KW - AbBB-Schema KW - Kammermessungen KW - Laborvergleich PY - 2007 UR - http://www.umweltbundesamt.de/publikationen/umwelt-gesundheitsanforderungen-an-bauprodukte SN - 1862-4804 IS - 16 SP - 383 Seiten PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-14791 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - MacLean, J. A1 - Mayanna, S. A1 - Benning, L. G. A1 - Horn, F. A1 - Bartholomäus, A. A1 - Wiesner, Yosri A1 - Wagner, D. A1 - Liebner, S. T1 - The terrestrial plastisphere: Diversity and polymer-colonizing potential of plastic-associated microbial communities in soil JF - Microorganisms N2 - The concept of a ‘plastisphere microbial community’ arose from research on aquatic plastic debris, while the effect of plastics on microbial communities in soils remains poorly understood. Therefore, we examined the inhabiting microbial communities of two plastic debris ecosystems with regard to their diversity and composition relative to plastic-free soils from the same area using 16S rRNA amplicon sequencing. Furthermore, we studied the plastic-colonizing potential of bacteria originating from both study sites as a measure of surface adhesion to UV-weathered polyethylene (PE) using high-magnification field emission scanning electron microscopy (FESEM). The high plastic content of the soils was associated with a reduced alpha diversity and a significantly different structure of the microbial communities. The presence of plastic debris in soils did not specifically enrich bacteria known to degrade plastic, as suggested by earlier studies, but rather shifted the microbial community towards highly abundant autotrophic bacteria potentially tolerant to hydrophobic environments and known to be important for biocrust formation. The bacterial inoculates from both sites formed dense biofilms on the surface and in micrometer-scale surface cracks of the UV-weathered PE chips after 100 days of in vitro incubation with visible threadlike EPS structures and cross-connections enabling surface adhesion. High-resolution FESEM imaging further indicates that the microbial colonization catalyzed some of the surface degradation of PE. In essence, this study suggests the concept of a ‘terrestrial plastisphere’ as a diverse consortium of microorganisms including autotrophs and other pioneering species paving the way for those members of the consortium that may eventually break down the plastic compounds. KW - Soil microbial community KW - Polyethylene colonization KW - Plastic pollution PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-542790 DO - https://doi.org/10.3390/microorganisms9091876 VL - 9 IS - 9 SP - 1 EP - 19 PB - MDPI CY - Basel AN - OPUS4-54279 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandt, S. A1 - Müller, B. A1 - de Lima Vasconcelos, S. A1 - Plehn, W. A1 - Brozowski, F. A1 - Horn, Wolfgang A1 - Sattler, M. T1 - Präzisierung der Geruchsprüfung für Bauprodukte nach DIN ISO 16000-28 – Untersuchung von Vergleichsmaßstäben T2 - Umwelt, Gebäude & Gesundheit: "Neu"- und Altlasten, Innenraumhygiene, Gerüche N2 - Bauprodukte, die in Innenräumen verwendet werden, sollten die Gesundheit und das Wohlbefinden der Personen die sich darin aufhalten nicht durch das Ausdünsten von Geruchsstoffen stören. Die DIN ISO 16000-28 „Bestimmung der Geruchsstoffemissionen aus Bauprodukten mit einer Emissionsprüfkammer“ (DIN ISO 16000-28) beschreibt umfassend die Möglichkeiten der Geruchsprüfung. In Verbindung mit der Anwendung der VDI-Richtlinie 4302 Blatt 1 „Geruchsprüfung von Innenraumluft und Emissionen aus Innenraummaterialien“ (VDI 4302 Blatt 1) ist sie zur Bewertung der empfundenen Intensität von Bauprodukten mit Vergleichsmaßstab geeignet (Umweltbundesamt 2015). In einem vom Umweltbundesamt (UBA) geförderten Forschungsprojekt der Hochschule für Technik und Wirtschaft Berlin (HTW Berlin) und der Bundesanstalt für Materialforschung und –prüfung (BAM) wurden erstmals verschiedene Vergleichsmaßstäbe miteinander verglichen. Ziel des derzeitigen Folgeprojektes ist nun, Mindestanforderungen an Vergleichsmaßstäbe zu erarbeiten, welche die Reproduzierbarkeit der Ergebnisse erhöhen und mit denen die Norm konkretisiert werden kann. Dieser Beitrag stellt die Untersuchungen und Ergebnisse des ersten Projektes und die Schlussfolgerungen für die Durchführung des zweiten Projektes dar. T2 - 12. Fachkongress der Arbeitsgemeinschaft ökologischer Forschungsinstiute (AGÖF) CY - Hallstadt (Bamberg), Germany DA - 17.10.2019 KW - Geruch KW - Emission KW - Bauprodukte KW - VOC KW - Emissionskammer PY - 2019 SN - 978-3-930576-11-1 VL - 12. Fachkongress SP - 214 EP - 223 PB - Arbeitsgemeinschaft ökologischer Forschungsinstiute (AGÖF) e. V. CY - Springe-Eldagsen AN - OPUS4-49702 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandt, S. A1 - Brozowski, F. A1 - Plehn, W. A1 - Horn, Wolfgang A1 - Müller, B. T1 - Further Development of Odour Testing of Building Products – Sample Presentation and Evaluation of Perceived Intensity T2 - 17th International Conference HEALTHY BUILDINGS EUROPE 2021 N2 - Indoor air quality is affected by the emission of volatile organic compounds (VOC) or the odour from building products. Odours can be measured by applying the standard ISO 16000-28:2020. In the study presented here proposals for further technical development of the ISO method are presented. The sampling procedure and evaluation method of the perceived intensity are investigated in particular because they have a major influence on reproducibility of measurement results. T2 - 17th International Conference HEALTHY BUILDINGS EUROPE 2021 CY - Online meeting DA - 21.06.2021 KW - Geruchsmessung KW - Emissionen KW - Bauprodukte KW - VOC KW - Perceived Intensity PY - 2021 SN - 978-82-536-1728-2 VL - 2021 SP - 1 EP - 4 PB - SINTEF Books CY - Oslo, Norwegen AN - OPUS4-54574 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandt, S. A1 - Brozowski, F. A1 - Horn, Wolfgang A1 - Müller, B. T1 - Odour testing of building products: Examinations for an on-going development of the test standard ISO 16000-28 T2 - Proceedings of healthy buildings 2023 Europe N2 - VOC-emissions and their odours from building products and furnishings present indoors should not have an impact on personal well-being or health. Odours can be measured by applying the standard ISO 16000-28. Indoor air determination of odour emissions from building products using test chambers. One of the described procedures is the assessment of perceived intensity using a comparative scale by a group of panellists. In this paper, the perceived intensity sampling procedure and its evaluation method are investigated and shown to need improvement. New technical developments in the methodology used to increase the reproducibility of measurement results are discussed. Since odour tests are used for labelling, they have a major influence on the assessment of construction products, similar to the procedure of the German Committee for Health Evaluation of Building Products (AgBB). In the original ISO standard, the evaluation is typically performed using a sampling container separated from the emission chamber. For a better sample presentation, an adapter was developed to connect the emission test chamber to the evaluation funnel and thus enable an odour assessment which is comparable to a direct measurement. The investigations show that losses of odourous substances can be greatly reduced, which is very desirable when seeking to obtain reliable results in odour measurement. Another experimental series was carried out to reduce the measurement effort in the evaluation of perceived intensity. Application of the developed greater than or less than/equal to. query could be helpful here. The results show that the query mostly leads to the same result as the evaluation of the perceived intensity using the method according to the standard but is much easier to perform. Overall, the results can contribute to improving the acceptance of the evaluation of perceived intensity using ISO 16000-28 and to determining odours from building materials increasingly more precisely. T2 - Healthy Buildings 2023 Europe CY - Aachen, Germany DA - 11.06.2023 KW - Building material KW - Odour KW - Perceived intensity KW - VOC KW - Emission test chamber PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-580070 SP - 345 EP - 352 PB - ISIAQ (International Society of Indoor Air Quality and Climate) CY - Herndon, VA, USA AN - OPUS4-58007 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Brandt, S. A1 - Brozowski, F. A1 - Horn, Wolfgang A1 - Plehn, W. A1 - Müller, B. T1 - New developments in odour testing: Adapter connects emission test chamber and funnel T2 - Proceedings: CLIMA 2022 The 14th REHVA HVAC World Congress N2 - Healthy and energy efficient buildings must be free from disturbing odours. Odour emissions from building materials can be measured with the well-known and accepted standard ISO 16000-28 “Indoor air – Part 28: Determination of odour emissions from building products using test chambers”. For commonly used emission test chambers the sample air is collected in containers (bags) and presented to a group of panel members for the purpose of evaluating the odour. A standard sets requirements for the on-demand presentation in detail. These include the validation procedure for container materials, pre-treatment of bags, details on storage of filled bags and how to carry out the measurements. However, although these measures are proven in practice, incorrect measurements are still possible. Also errors can occur due to a very complex measurement procedure. So, there is a great need for research into how the odour samples are presented. The proposal planned to be presented will introduce a new development in sample provision by using an adapter which enables collection and provision of sample air without storage or transport of bags. The adapter is a sample container which is permanently positioned on the emission test chamber´s outlet and continuously filled with sample air flowing through it. The flow is briefly interrupted at the time when a sample is taken by a panel member for the test. The size of the container is sufficient to provide enough sample air for evaluation by at least one panel member via a funnel. Since sampling and presentation are technically connected, it means you can almost do away with storage or transportation and thus it can be presented almost unchanged to the panelmembers. The aim is to reduce measurement errors in the odour samples provision process and the improvement of measurement reproducibility. The paper presents the construction of the adapter as well as the results of emission and odour tests carried out so far. T2 - CLIMA 2022 The 14th REHVA HVAC World Congress CY - Rotterdam, The Netherlands DA - 22.05.2022 KW - Perceived Intensity KW - Emissionen KW - Geruch KW - Bauprodukte PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-556192 DO - https://doi.org/10.34641/clima.2022.168 SP - 1 EP - 5 PB - TU Delft open CY - Delft, Niederlande AN - OPUS4-55619 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brandt, S. A1 - Müller, B. A1 - Brozowski, F. A1 - Plehn, W. A1 - Horn, Wolfgang T1 - Weiterentwicklung des Geruchsmessverfahrens für Bauprodukte T1 - Further development of the odour measurement method for building products JF - Gefahrstoffe, Reinhaltung der Luft = Air quality control N2 - Bauprodukte und Einrichtungsgegenstände für Innenräume, wie Bodenbeläge und Wandpaneele, sollen das Wohlbefinden und die Gesundheit der Raumnutzerinnen und -nutzer nicht durch das Ausdünsten von Geruchsstoffen stören. Mit der Geruchsprüfung nach ISO 16000-28 „Innenraumluft - Bestimmung der Geruchsstoffemissionen aus Bauprodukten mit einer Emissionsprüfkammer“ wird der Produktgeruch zu einer messbaren Größe. So kann z. B. die empfundene Intensität, also die Stärke eines Geruchseindruckes, mit Hilfe eines Vergleichsmaßstabes von Probandinnen und Probanden ermittelt werden. Im hier vorgestellten Projekt werden Vorschläge zur Weiterentwicklung der Methode vorgestellt, um im Ergebnis die Reproduzierbarkeit der Messergebnisse weiter zu verbessern. Dabei werden vor allem das Probenpräsentationssystem und die Bewertungsmethodik für die empfundene Intensität bei der Bewertung von Bauprodukten gemäß AgBB-Schema betrachtet, da diese einen wesentlichen Einfluss haben. N2 - Emissions or odours occurring from building products and furnishings for interiors, like floor coverings or wall panels, should not have a negative impact on well-being or health. Odours can be measured applying the standard ISO 16000-28 „Indoor air - Determination of odour emissions from building products using test chambers” It describes among other procedures the assessment of perceived intensi-ty with comparative scale by a group of panellists. In the study presented here, proposals for further technical development of the methodology are discussed to increase the reproducibility of measurement results. The sampling procedure and evaluation method of perceived intensity are investigated in particular because they have a major influence at the assessment of construction products applying the procedure of the Committee for Health Evaluation of Building Products. KW - Geruchsmessung KW - Emissionen KW - Bauprodukte KW - VOC PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-527458 UR - http://www.gefahrstoffe.de SN - 0949-8036 SN - 1436-4891 VL - 81 IS - 3-4 SP - 151 EP - 155 PB - VDI Fachmedien CY - Düsseldorf AN - OPUS4-52745 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, B. A1 - Bitter, F. A1 - Müller, D. A1 - Knudsen, H.N. A1 - Afshari, A. A1 - Wargocki, P. A1 - Olesen, B. A1 - Berglund, B. A1 - Ramalho, O. A1 - Goschnick, J. A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Nesa, D. A1 - Chanie, E. A1 - Ruponen, M. T1 - Messung der empfundenen Geruchsintensität mit Multigas-Sensorsystemen, das Forschungsvorhaben SysPAQ T2 - VDI-Berichte "Gerüche in der Umwelt - Innenraum- und Außenluft" / Tagung 13.- 14.11.2007, Bad Kissingen KW - Geruch KW - Sensorsystem KW - Perceived Air Quality KW - Produkttypischer Geruch KW - Bauprodukte KW - Emissionen PY - 2007 SN - 978-3-18-091995-9 SN - 0083-5560 IS - 1995 SP - 17 EP - 29 PB - VDI-Verl. CY - Düsseldorf AN - OPUS4-16370 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Däumling, C. A1 - Brenske, K.-R. A1 - Crump, D. A1 - Funch, L. W. A1 - Hansen, K. A1 - Horn, Wolfgang A1 - Kephalopoulos, S. A1 - Maupetit, F. A1 - Saarela, K. A1 - Tirkkonen, T. A1 - Witterseh, T. T1 - Harmonisation of material emission labelling schemes in the EU T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate, August 17-22, 2008, Copenhagen, Denmark (Proceedings) T2 - Indoor Air 2008, 11th International Conference on Indoor Air Quality and Climate CY - Copenhagen, Denmark DA - 2008-08-17 KW - Labelling scheme KW - Evaluation system KW - Material emission KW - Harmonisation PY - 2008 SP - 1 AN - OPUS4-18046 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kephalopoulos, S. A1 - Däumling, C. A1 - Crump, D. A1 - Funch, L. W. A1 - Horn, Wolfgang A1 - Maupetit, F. A1 - Saarela, K. A1 - Säteri, J. A1 - Tirkkonen, T. A1 - Witterseh, T. T1 - Harmonisation of indoor material emission labelling schemes in the EU - VOC workshop T2 - Healthy buildings 2009 - 9th International conference & exhibition (Proceedings) T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - Labelling schemes KW - Indoor material emissions KW - VOC KW - Framework KW - Harmonisation PY - 2009 IS - Paper 635 SP - 1 EP - 4 CY - Syracuse, NY, USA AN - OPUS4-19925 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, B. A1 - Dahms, A. A1 - Jakob, B. A1 - Knudsen, H.N. A1 - Afshari, A. A1 - Wargocki, P. A1 - Olesen, B. A1 - Berglund, B. A1 - Ramalho, O. A1 - Häringer, D. A1 - Jann, Oliver A1 - Horn, Wolfgang A1 - Nesa, D. A1 - Loubet, F. A1 - Ruponen, M. T1 - Measuring perceived air quality and intensity by means of sensor systems, the European Project SysPAQ T2 - Healthy buildings 2009 - 9th International conference & exhibition (Proceedings) T2 - Healthy buildings 2009 - 9th International conference & exhibition CY - Syracuse, NY, USA DA - 2009-09-13 KW - Sensor systems KW - Perceived air quality KW - Perceived intensity PY - 2009 IS - Paper 326 SP - 1 EP - 4 CY - Syracuse, NY, USA AN - OPUS4-20106 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -