TY - JOUR A1 - Pitkänen, J. A1 - Bertovic, Marija A1 - Brackrock, Daniel A1 - Brekow, Gerhard A1 - Ewert, Uwe A1 - Kanzler, Daniel A1 - Müller, Christina T1 - Reliable evaluation of acceptability of weld for final disposal based on the canister copper weld inspection using different NDT methods N2 - The inspection of the sealing weld is an important phase for the evaluation of the acceptability of final disposal canister, but the weld is only a part of the 3D shielding of copper shell. The main tasks for reliable NDT evaluation requires an extensive evaluation of the parameters – which contains typical inspection related items like repeatability, S/N ratio, POD, setting up the equipment for inspection, and all practices for inspections. The other parameters are material parameters, their variation must be taken into account in the evaluation of NDT reliability. Further parameters include human factors, i. e. human inspectors and their interaction with technical systems; their effects were studied on an example of the evaluation of eddy current data. Final parameters are related to evaluation of detected defects, which means sizing and base for acceptance and this can be done in different ways. Some examples are given and results are compared with different methods for instance between radiographic testing and ultrasonic testing by raw data analysis and PA-SAFT results. Also, preliminary curves for the evaluation of metallographic results of 55 defects will be shown by EB weld measurements. Some practical items concerning copper inspections will be also discussed related to acceptability. N2 - Die Prüfung der Verschlussschweißnaht ist eine wichtige Phase in der Akzeptanzbewertung der Endlagerungskanister, obwohl die Verschlussschweißnaht nur ein Teil der dreidimensionalen Bedeckung der Kupfereinhüllung ist. Die Hauptaufgabe für die sichere zerstörungsfreie Prüfung (ZfP) erfordert eine umfangreiche Bewertung der Prüfparameter, die die typischen Prüfeinzelheiten, wie z. B. Wiederholbarkeit, Signal-Rausch-Verhältnis, POD, Einstellung der Geräte und alle Prüfvorgehen enthalten. Weitere Parameter sind die Schwankungen von Materialeigenschaften, die berücksichtigt werden müssen. Andere Parameter sind menschliche Faktoren, wie z. B. die Prüfer, und deren Interaktion mit den technischen Systemen, beispielsweise bei der Bewertung der Wirbelstromdaten. Weitere Einflussgrößen auf die Prüfung entstehen bei der Bewertung gefundener Fehler, bei der Größenbestimmung von Fehlern und basierend auf der strukturellen Integrität bei der Akzeptanz von definierten Fehlergrößen/Fehlerarten an verschiedenen Positionen in der Schweißnaht. Der Artikel zeigt einige Beispiele und den Vergleich zwischen verschiedenen ZfP-Methoden, z. B. der radiographische Prüfung, der Ultraschallprüfung mit Bewertung von Rohdaten und der Ultraschallprüfung mit Bewertung mittels PA-SAFT. Auch die vorläufigen Kurven für die metallographische Bewertung von 55 Fehlern der Elektronenstrahlschweißung sind gezeigt. Darüber hinaus wird auch eine praktische Vorgehensweise bei der Definition der Akzeptanzkriterien für die Kupferschweißnahtsprüfung diskutiert. KW - NDT reliability KW - Radiography KW - Ultrasonic testing KW - Eddy current testing KW - Visual testing PY - 2014 UR - http://www.hanser-elibrary.com/doi/pdf/10.3139/120.110609 DO - https://doi.org/10.3139/120.110609 SN - 0025-5300 VL - 56 IS - 9 SP - 748 EP - 757 PB - Hanser CY - München AN - OPUS4-31524 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Redmer, Bernhard A1 - Ewert, Uwe T1 - Mobile X-ray computed tomography for nuclear and aviation industry N2 - Digital detectors such as phosphor imaging plates (IP) and digital detector arrays (DDA) enable radiographic inspection with higher efficiency and improved image quality in comparison to the classic film technique. The mobile mechanised tomographic system TomoCAR (tomographic computer aided radiology) was developed first for inspection of circumferential welded seams of pipes. It consists of the manipulator based position control of an X-ray tube in front of the region to inspect and a digital detector array behind it. The high contrast sensitivity technique was combined with planar tomography. The tomographic reconstruction allows the three-dimensional (3D) representation of the material structure and included defects, equivalent to a metallographic cross sectioning. The hardware design is based on a specially developed flat X-ray tube and a direct converting CMOS detector array on CdTe basis. TomoCAR is applied for sizing of volumetric and planar defects. It allows the reliable detection of planar defects with openings larger than 25µm by subpixel resolution due to the achieved high signal-to-noise ratio. TomoCAR was successfully qualified as the result of a German pilot study on the basis of the European Network of Inspection and Qualification (ENIQ) guidelines for application in the nuclear power industry. Application examples are presented. The TomoCAR design was modified for in situ inspection of large aircraft components under production conditions. A gantry gate based planar tomograph was constructed and tested for inspection of the integrity of large flat CFRP panel components of up to 3 m × 9 m size. The integrity of imbedded stringers has been successfully observed. Different trials were performed to prove the finding rate of cracks in embedded stringers, which will be presented and discussed. KW - Computertomographie KW - Röntgen KW - Schweißen KW - Kerntechnik KW - Ferritischer Stahl KW - Austenitischer Stahl KW - Luftfahrt KW - Faserkomposite KW - Risse PY - 2013 DO - https://doi.org/10.3139/120.110504 SN - 0025-5300 VL - 55 IS - 10 SP - 760 EP - 764 PB - Hanser CY - München AN - OPUS4-29785 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe T1 - A Benchmark Concept for Simulation in Radiographic Testing T2 - Review of Progress in Quantitative Nondestructive Evaluation CY - Baltimore, MD, USA DA - 2013-07-22 PY - 2013 AN - OPUS4-30840 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Pitkänen, J. A1 - Bertovic, Marija A1 - Brackrock, Daniel A1 - Brekow, Gerhard A1 - Ewert, Uwe A1 - Kanzler, Daniel A1 - Müller, Christina T1 - Reliable evaluation of the acceptability of the weld for final disposal based on the canister copper weld inspection using different NDT methods N2 - The inspection of the sealing weld is an important phase for the evaluation of the acceptability of final disposal canister, but the weld is only a part of the 3D shielding of copper shell. The main tasks for reliable NDT evaluation requires an extensive evaluation of the parameters - which contains typical inspection related items like repeatability, S/N ratio, POD, setting up the equipment for inspection, and all practices for inspections. The other parameters are material parameters, their variation must be taken into account in the evaluation of NDT reliability. Further parameters include human factors, i.e. human inspectors and their interaction with technical systems; their effects were studied on an example of the evaluation of eddy current data. Final parameters are related to evaluation of detected defects, which means sizing and base for acceptance and this can be done in different ways. Some examples are given and results are compared with different methods for instance between radiographic testing and ultrasonic testing by raw data analysis and PA-SAFT results. Also, preliminary curves for the evaluation of metallographic results of 55 defects will be shown by EB weld measurements. Some practical items concerning copper inspections will be also discussed related to acceptability. T2 - 5th European-American workshop on reliability of NDE CY - Berlin, Germany DA - 07.10.2013 PY - 2013 SN - 978-3-940283-53-5 IS - DGZfP-BB 144 SP - Lecture 37, 1 EP - 13 CY - Berlin AN - OPUS4-31267 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ewert, Uwe T1 - Progress in digital industrial radiology - Part 1: Radiographic techniques-film replacement and backscatter imaging N2 - Similar to the success story of digital photography a major upheaval has been observed in digital industrial radiology. This paper is split into 3 parts: Part 1: Film Replacement and Backscatter Imaging: Computed radiography with phosphor imaging plates substitutes film applications. Digital Detector Arrays enable an extraordinary increase of contrast sensitivity in comparison to film radiography. The increased sensitivity of digital detectors enables the efficient usage for dimensional measurements and functionality tests substituting manual maintenance. The digital measurement of wall thickness and corrosion status is state of the art in petrochemical industry. Photon counting and energy discriminating detectors are applied up to 300 Kv provide increased thickness dynamic and material discrimination by synchronously acquisition of images of the high and low energy part of the spectrum. X-ray back scatter techniques have been applied in safety and security relevant applications with single sided access of source and detector. First inspections of CFRP in aerospace industry were successfully conducted with newly designed back scatter cameras. Numeric modeling is used to design X-Ray optics and inspection scenarios as well as conducting RT training. Part 2: Computed tomography (CT) Part 3: Micro Radiography and Micro CT. KW - Digital radiography KW - Computed tomography KW - Laminography KW - Imaging plates KW - Digital detector arrays KW - Photon counting detectors KW - Back scatter KW - Numeric modelling KW - CFRP KW - Welding KW - Corrosion PY - 2016 VL - 1-2 SP - 37 EP - 43 AN - OPUS4-39163 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kolkoori, Sanjeevareddy A1 - Wrobel, Norma A1 - Hohendorf, Stefan A1 - Ewert, Uwe T1 - High energy X-ray imaging technology for the detection of dangerous materials in air freight containers N2 - In the context of the German aviation security research and development project SILUFRA (secure air freight transport chains), BAM has developed a high-resolution and high-energy X-ray imaging technology for the reliable detection of dangerous and illicit materials in densely packed air freight containers. In the developed technology, a novel combination of high-energy (2-7.5 MeV) X-ray betatron as the radiation source and a high-resolution digital detector array (DDA) for the X-ray imaging was utilized to improve the probability of detecting contraband and explosive materials by enhancing the spatial and contrast resolution in the digital X-ray image. In addition, flexible rotations of the high-energy X-ray source and the digital detector array can lead to clarify the suspicious region of interest (ROI) in air freight containers efficiently. Thus, reduces the false alarm rates and the need for expensive manual inspections of the whole container load. In order to evaluate the detection efficiency, we carried out the experimental investigations on a real air freight container loaded with typical cargo materials such as heavy automobile components and electronic products as well as mock-up dangerous and contraband materials. Furthermore, the material discrimination in the radiographic images was evaluated based on the dual high-energy X-ray imaging method. Finally, important applications of the proposed imaging technology to the air cargo security are discussed T2 - 2015 IEEE International Symposium on Technologies for Homeland Security (HST) CY - Waltham, MA, USA DA - 14.04.2015 KW - High-energy X-ray imaging KW - Betatron KW - Digital detector array (DDA) KW - Container inspection KW - Spatial resolution PY - 2015 SN - 978-1-4799-1736-5 DO - https://doi.org/10.1109/THS.2015.7225328 SP - 1 EP - 6 PB - IEEE AN - OPUS4-34025 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kolkoori, Sanjeevareddy A1 - Wrobel, Norma A1 - Ewert, Uwe T1 - A new X-ray backscatter technology for aviation security applications N2 - In order to enhance the supply chain security at airports, the German federal ministry of education and research has initiated the project ESECLOG (enhanced security in the air cargo chain) which has the goal to improve the threat detection accuracy using one-sided access methods. In this paper, we present a new X-ray backscatter technology for non-intrusive imaging of suspicious objects (mainly low-Z explosives) in luggage's and parcels with only a single-sided access. A key element in this technology is the X-ray backscatter camera embedded with a special twisted-slit collimator. The developed technology has efficiently resolved the problem related to the imaging of complex interior of the object by fixing source and object positions and changing only the scanning direction of the X-ray backscatter camera. Experiments were carried out on luggages and parcels packed with mock-up dangerous materials including liquid and solid explosive simulants. In addition, the quality of the X-ray backscatter image was enhanced by employing high-resolution digital detector arrays. Experimental results are discussed and the efficiency of the present technique to detect suspicious objects in luggages and parcels is demonstrated. At the end, important applications of the proposed backscatter imaging technology to the aviation security are presented. T2 - 2015 IEEE International Symposium on Technologies for Homeland Security (HST) CY - Waltham, MA, USA DA - 14.04.2015 KW - X-ray backscatter imaging KW - Digital radiography KW - Detection of dangerous materials KW - Luggage inspection KW - One-sided access method KW - Security applications PY - 2015 SN - 978-1-4799-1736-5 DO - https://doi.org/10.1109/THS.2015.7225329 SP - 1 EP - 5 PB - IEEE AN - OPUS4-34027 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe T1 - High-Resolution X-ray Backscatter Technique for Nondestructive Imaging of Aerospace Components T2 - Digital Industrial Radiology and Computed Tomography (DIR 2015) CY - Ghent, Belgium DA - 2015-06-22 PY - 2015 AN - OPUS4-34047 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Christina A1 - Pavlovic, Mato A1 - Takahashi, Kazunori A1 - Ewert, Uwe A1 - Rosenthal, Martina A1 - Brekow, Gerhard A1 - Böhm, R. A1 - Ronneteg, U. A1 - Pitkänen, J. T1 - POD Evaluation of NDE Techniques for Canister-Components for Risk Assessment of Nuclear Waste Encapsulation T2 - 6th International Conference on NDE in Relation to Structural Integrity for Nuclear and Pressurised Components CY - Budapest, Hungary DA - 2007-10-08 KW - Zerstörungsfreie Prüfung KW - Zuverlässigkeit KW - POD PY - 2008 SN - 978-92-79-08897-1 DO - https://doi.org/10.2790/1274 SN - 1018-5593 SP - 168 EP - 179 AN - OPUS4-18589 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe T1 - Mobile X-Ray Inspection of Light Weight Materials T2 - International Symposium on NDT in Aeorspace CY - Fürth, Germany DA - 2008-12-03 PY - 2008 AN - OPUS4-18782 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - von Chrzanowski, Lars A1 - Beckmann, Jörg A1 - Marchetti, Barbara A1 - Ewert, Uwe A1 - Schade, U. T1 - Capability of terahertz-wave instrumentation for non destructive testing of liquids T2 - 10th European conference on non-destructive testing CY - Moscow, Russia DA - 2010-06-07 KW - Terahertz PY - 2010 UR - http://www.ndt.net/article/ecndt2010/reports/1_05_16.pdf IS - Paper 4.02.18 SP - 1 EP - 8 AN - OPUS4-21685 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Beckmann, Jörg A1 - Schmidt, Richard A1 - Ewert, Uwe A1 - Berndt, A. A1 - Strebl, F. T1 - Agenda 2020 for a European Certification System for CBRNE Sensor Systems and Devices - the Concept for a Road Map N2 - Developments for technologies were initiated by the European Commission to improve future response capabilities and strategies to prevent terrorist attacks, to reduce the vulnerability to terrorism and to minimize the extent of damage from terrorist attacks. CBRN civil protection faces a growing significance in this concept and modern detectors and detection systems play the key role for a future reliable functioning that counters terrorism in Europe. The European Union is supporting the project CREATIF which is dedicated to provide a communication platform for technology users and decision makers, providers, and testers. First ideas were designed, strategies developed, preconditions and rules were named for a future internationally recognized certification system. A concept for a future European Certification System for CBRNE Sensor Systems and Devices and Processes has been developed, which is described in more detail. T2 - 1st International symposium on development of CBRN defence capabilities CY - Berlin, Germany DA - 2010-11-30 KW - WMD KW - CBRNE KW - Certification KW - Testing PY - 2010 SN - 978-3-935938-75-4 IS - P10.5 SP - 1603 EP - 1606 CY - Bonn AN - OPUS4-22879 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe T1 - Neue Algorithmen zur Messung der Filmsystem-Parameter im Rahmen der Revision der Norm EN 584, Teil 1 T2 - DGZfP-Jahrestagung 2001, Zerstörungsfreie Materialprüfung, ZfP in Anwendung, Entwicklung und Forschung CY - Berlin, Germany DA - 2001-05-21 PY - 2001 AN - OPUS4-22927 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe T1 - Einsatz eines mobilen Speicherfoliensystems zur Untersuchung kampfstoffverdächtiger Granaten T2 - DGZfP-Jahrestagung 2001, Zerstörungsfreie Materialprüfung, ZfP in Anwendung, Entwicklung und Forschung CY - Berlin, Germany DA - 2001-05-21 PY - 2001 AN - OPUS4-22928 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe T1 - DIN EN 12062 - "ZfP von Schweißverbindungen - Allgmeine Regeln für metallische Werkstoffe" und Zuverlässigkeitsgrenzen T2 - 3. Fachseminar Verfahrens- und Produktnormen in der ZfP CY - Dortmund, Germany DA - 2007-10-01 PY - 2007 AN - OPUS4-22915 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe T1 - Hochkontrastempfindlichkeits-Radiographie für Luftfahrtkomponenten T2 - 13. Seminar Aktuelle Fragen der Durchstrahlungsprüfung und des Strahlenschutzes CY - Mannheim, Germany DA - 2007-11-01 PY - 2007 AN - OPUS4-22916 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe T1 - Digitale Radiologie in der ZfP - Belichtungszeit und Kontrastempfindlichkeit - Der Äquivalenzwert zur optischen Dichte des Films T2 - DGZfP-Jahrestagung 2005, Vortrag 23 CY - Rostock, Germany DA - 2005-05-02 PY - 2005 AN - OPUS4-22917 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe T1 - Digitale Radiographie mit Speicherfoliensystemen in der industriellen Durchstrahlungsprüfung T2 - DGZfP-Jahrestagung 2001, Zerstörungsfreie Materialprüfung, ZfP in Anwendung, Entwicklung und Forschung CY - Berlin, Germany DA - 2001-05-21 PY - 2001 AN - OPUS4-22923 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ewert, Uwe A1 - Redmer, Bernhard A1 - Rädel, Christoph A1 - Osterloh, Kurt A1 - Schnars, U. A1 - Henrich, R. A1 - Schimmelmann, O. A1 - Bavendiek, K. A1 - Jahn, M. T1 - Mobile X-ray Inspection of light weight materials N2 - Digital detectors such as phosphor imaging plates (IP) and digital detector arrays (DDA) allow radiographic inspection with higher efficiency and improved image quality in comparison to the classic film technique. Mobile X-ray flash tubes are used routinely for veterinarian and security applications. New high sensetive IPs and DDAs enable to apply them for inspection of light materials with low X-ray attenuation as in aluminium, plastics and composites. A versatile computed tompgraphy (CT) system was developed for in situ inspection of large aircraft components under production conditions. A gate based planar computed tomograph wsa developed and testes for inspection of integrety of the stringer incorporation. Successful test trials were performed to prove the detection rate of cracks in embedded stringers. Honey comb structures of aircrafts have to be inspected for water inclusions during in-service inspections. Thermography is a powerful method for in house inspections when variations in temperature caused e. g. by sunshine can be excluded. A new X-ray diaphragm was developed for mobile back scatter measurements of large components. This method is insensitive to heat alterations in the field and thus can be applied also outdoors. T2 - International Symposium on NDT in Aerospace CY - Fürth, Germany DA - 2008-12-03 KW - X-ray light materials KW - Computertomography KW - Laminography KW - Backscatter KW - Fibre composites KW - Flash generator PY - 2008 SN - 978-3-940283-12-2 N1 - Serientitel: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. – Series title: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. IS - 114 SP - 99 EP - 111 PB - DGZfP CY - Berlin AN - OPUS4-18927 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe A1 - Erhard, Anton T1 - Das TOFD-Verfahren zwischen Radiographie und Ultraschall bei der Schweißnahtprüfung T2 - DGZfP-Jahrestagung CY - Celle, Germany DA - 1999-05-10 PY - 1999 AN - OPUS4-18880 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe T1 - Technische Radiographie T2 - DGZfP-Jahrestagung 2007 CY - Fürth, Germany DA - 2007-05-14 PY - 2007 AN - OPUS4-19964 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe T1 - Mobile Computed Tomography T2 - INDE 2007 CY - Kalpakkam, India DA - 2007-04-25 PY - 2007 AN - OPUS4-19965 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -