TY - GEN A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Fratzscher, Daniel A1 - Alekseychuk, Oleksandr A1 - Einav, I. A1 - Infanzon, S. A1 - Zirnhelt, J. T1 - Optimization of Digital Industrial Radiography (DIR) Techniques for Specific Applications: An IAEA Coordinated Research Project T2 - 4. Conferencia Panamericana de END CY - Buenos Aires, Argentina DA - 2007-10-22 KW - Radiographie KW - Digitale Detektoren KW - Grenzen der Bildqualität KW - Preiswerte Prüftechnik PY - 2007 SN - 978-987-23957-0-4 IS - CD-ROM SP - 1 EP - 6 AN - OPUS4-16424 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Bavendiek, K. T1 - Strategies for Film Replacement in Radiography - a comparative study T2 - 4. Conferencia Panamericana de END CY - Buenos Aires, Argentina DA - 2007-10-22 KW - Radiographie KW - Digitale Detektoren KW - Grenzen der Bildqualität KW - Vergleich Film KW - Speicherfolien KW - Detektor-Arrays PY - 2007 SN - 978-987-23957-0-4 IS - CD-ROM SP - 1 EP - 18 AN - OPUS4-16425 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Osterloh, Kurt A1 - Bücherl, T. A1 - Lierse von Gostomski, C. A1 - Zscherpel, Uwe A1 - Ewert, Uwe A1 - Bock, S. T1 - Filtering algorithm for dotted interferences N2 - An algorithm has been developed to remove reliably dotted interferences impairing the perceptibility of objects within a radiographic image. This particularly is a major challenge encountered with neutron radiographs collected at the NECTAR facility, Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II): the resulting images are dominated by features resembling a snow flurry. These artefacts are caused by scattered neutrons, gamma radiation, cosmic radiation, etc. all hitting the detector CCD directly in spite of a sophisticated shielding. This makes such images rather useless for further direct evaluations. One approach to resolve this problem of these random effects would be to collect a vast number of single images, to combine them appropriately and to process them with common image filtering procedures. However, it has been shown that, e.g. median filtering, depending on the kernel size in the plane and/or the number of single shots to be combined, is either insufficient or tends to blur sharp lined structures. This inevitably makes a visually controlled processing image by image unavoidable. Particularly in tomographic studies, it would be by far too tedious to treat each single projection by this way. Alternatively, it would be not only more comfortable but also in many cases the only reasonable approach to filter a stack of images in a batch procedure to get rid of the disturbing interferences. The algorithm presented here meets all these requirements. It reliably frees the images from the snowy pattern described above without the loss of fine structures and without a general blurring of the image. It consists of an iterative, within a batch procedure parameter free filtering algorithm aiming to eliminate the often complex interfering artefacts while leaving the original information untouched as far as possible. KW - Neutron KW - Radiography KW - Tomography KW - Filtering KW - Evaluation KW - NECTAR PY - 2011 DO - https://doi.org/10.1016/j.nima.2011.01.107 SN - 0168-9002 SN - 0167-5087 VL - 651 IS - 1 SP - 171 EP - 174 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-24917 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Osterloh, Kurt A1 - Fratzscher, Daniel A1 - Schwabe, A. A1 - Schillinger, B. A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Radiography and partial tomography of wood with thermal neutrons N2 - The effective high neutron scattering absorption coefficient of hydrogen (48.5 cm²/g) due to the scattering allows neutrons to reveal hydrocarbon structures with more contrast than X-rays, but at the same time limits the sample size and thickness that can be investigated. Many planar shaped objects, particularly wood samples, are sufficiently thin to allow thermal neutrons to transmit through the sample in a direction perpendicular to the planar face but not in a parallel direction, due to increased thickness. Often, this is an obstacle that prevents some tomographic reconstruction algorithms from obtaining desired results because of inadequate information or presence of distracting artifacts due to missing projections. This can be true for samples such as the distribution of glue in glulam (boards of wooden layers glued together), or the course of partially visible annual rings in trees where the features of interest are parallel to the planar surface of the sample. However, it should be possible to study these features by rotating the specimen within a limited angular range. In principle, this approach has been shown previously in a study with fast neutrons [2]. A study of this kind was performed at the Antares facility of FRM II in Garching with a 2.6×107/cm² s thermal neutron beam. The limit of penetration was determined for a wooden step wedge carved from a 2 cm×4 cm block of wood in comparison to other materials such as heavy metals and Lucite as specimens rich in hydrogen. The depth of the steps was 1 cm, the height 0.5 cm. The annual ring structures were clearly detectable up to 2 cm thickness. Wooden specimens, i.e. shivers, from a sunken old ship have been subjected to tomography. Not visible from the outside, clear radial structures have been found that are typical for certain kinds of wood. This insight was impaired in a case where the specimen had been soaked with ethylene glycol. In another large sample study, a planar board made of glulam has been studied to show the glued layers. This study shows not only the limits of penetration in wood but also demonstrates access to structures perpendicular to the surface in larger planar objects by tomography with fast neutrons, even with incomplete sets of projection data that covers an angular range of only 90° or even 60°. KW - Neutron computed tomography KW - Limited angle tomography KW - Wood KW - Annual rings PY - 2011 DO - https://doi.org/10.1016/j.nima.2011.02.095 SN - 0168-9002 SN - 0167-5087 VL - 651 IS - 1 SP - 236 EP - 239 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-24918 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wrobel, Norma A1 - Osterloh, Kurt A1 - Zscherpel, Uwe A1 - Ewert, Uwe ED - Ender, J. ED - Fiege, J. T1 - Variable irradiation geometry with a nex X-ray backscatter camera for security applications T2 - Future Security 2011 Conference CY - Berlin, Germany DA - 2011-09-05 KW - Technical safety and public security KW - Bridging separate competence areas PY - 2011 SN - 978-3-8396-0295-9 SP - 128 EP - 131 CY - Berlin AN - OPUS4-25355 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gollwitzer, Christian A1 - Bellon, Carsten A1 - Deresch, Andreas A1 - Ewert, Uwe A1 - Jaenisch, Gerd-Rüdiger A1 - Zscherpel, Uwe A1 - Mistral, Q. ED - Thompson, D. O. ED - Chimenti, D. E. T1 - Simulation supported POD for RT test case - concept and modeling N2 - Within the framework of the European project PICASSO, the radiographic simulator aRTist (analytical Radiographic Testing inspection simulation tool) developed by BAM has been extended for reliability assessment of film and digital radiography. NDT of safety relevant components of aerospace industry requires the proof of probability of detection (POD) of the inspection. Modeling tools can reduce the expense of such extended, time consuming NDT trials, if the result of simulation fits to the experiment. Our analytic simulation tool consists of three modules for the description of the radiation source, the interaction of radiation with test pieces and flaws, and the detection process with special focus on film and digital industrial radiography. It features high processing speed with near–interactive frame rates and a high level of realism. A concept has been developed as well as a software extension for reliability investigations, completed by a user interface for planning automatic simulations with varying parameters and defects. Furthermore, an automatic image analysis procedure is included to evaluate the defect visibility. The radiographic modeling from 3D CAD of aero engine components and quality test samples are compared as a precondition for real trials. This enables the evaluation and optimization of film replacement for application of modern digital equipment for economical NDT and defined POD. T2 - 38th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Burlington, VT, USA DA - 2011-07-17 KW - X-ray imaging KW - Probability of detection KW - Simulation KW - ZfP KW - Radiographie KW - POD PY - 2012 SN - 978-0-7354-1013-8 DO - https://doi.org/10.1063/1.4716283 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings VL - 31 IS - 1430 SP - 605 EP - 612 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-26696 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Heyne, Klara A1 - Jechow, Mirko A1 - Bavendiek, K. T1 - Image quality in digital industrial radiography KW - ZfP KW - Radiographie KW - Bildqualität KW - Digitale Detektoren PY - 2012 SN - 0025-5327 VL - 70 IS - 8 SP - 955 EP - 964 PB - Society for Nondestructive Testing CY - Columbus, Ohio AN - OPUS4-26699 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bavendiek, K. A1 - Heike, U. A1 - Kosanetzky, J.M. A1 - Ewert, Uwe A1 - Zscherpel, Uwe T1 - Best energy selection for different applications with digital detector arrays from 20 to 600 keV KW - ZfP KW - Radiographie KW - Bildqualität KW - Digitale Detektoren PY - 2012 SN - 0025-5327 VL - 70 IS - 8 SP - 965 EP - 974 PB - Society for Nondestructive Testing CY - Columbus, Ohio AN - OPUS4-26700 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe A1 - Heyne, Klara A1 - Zscherpel, Uwe A1 - Jechow, Mirko A1 - Bavendiek, K. ED - Thompson, D.O. ED - Chimenti, D.E. T1 - Optimum exposure conditions for computed radiography depending on fixed pattern noise and efficiency of imaging plate-scanner systems N2 - The presently active standards on Computed Radiography (CR) need a major revision. It was observed by many users that the image quality for class B of EN 14784-2 is not achievable under the same exposure conditions as used for film exposure. A mathematical model was developed and tested, which allows the calculation of the image quality, proven by image quality indicators (IQI), depending on the fixed pattern noise and the efficiency of the used imaging plate (IP) scanner system. All tested IP scanner systems provide a fixed correlation between the measured signal/noise ratio (SNR) and the grey values in the digital images. The maximum achievable SNRmax depends on the fixed pattern noise of the plate (high dose limit). Depending on the exposure dose an optimum visibility of IQIs can be predicted by calculation and measured considering the attenuation coefficient for calculation of the contrast/noise ratio (CNR). The diameter of the just visible wire is proportional to 1/sqrt(CNR). The optimum tube voltage for best visibility of IQIs and maximum CNR depend on the exposure dose. The optimum tube voltage for best visibility is achieved only at exposures with high dose. A dose dependant optimal tube voltage was not observed for film radiography. T2 - 37th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - San Diego, CA, USA DA - 18.07.2010 KW - Computed radiography KW - Computed radiology KW - Non destructive testing KW - Image quality KW - Signal-to-noise ratio KW - Contrast-to-noise ratio KW - Imaging plates KW - Optimum tube voltage KW - Standards PY - 2011 SN - 978-0-7354-0888-3 DO - https://doi.org/10.1063/1.3591892 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings IS - 1335 SP - 493 EP - 500 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-27540 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kolkoori, Sanjeevareddy A1 - Wrobel, Norma A1 - Osterloh, Kurt A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Novel X-ray backscatter technique for detection of dangerous materials: application to aviation and port security N2 - Radiological inspections, in general, are the nondestructive testing (NDT) methods to detect the bulk of explosives in large objects. In contrast to personal luggage, cargo or building components constitute a complexity that may significantly hinder the detection of a threat by conventional X-ray transmission radiography. In this article, a novel X-ray backscatter technique is presented for detecting suspicious objects in a densely packed large object with only a single sided access. It consists of an X-ray backscatter camera with a special twisted slit collimator for imaging backscattering objects. The new X-ray backscatter camera is not only imaging the objects based on their densities but also by including the influences of surrounding objects. This unique feature of the X-ray backscatter camera provides new insights in identifying the internal features of the inspected object. Experimental mock-ups were designed imitating containers with threats among a complex packing as they may be encountered in reality. We investigated the dependence of the quality of the X-ray backscatter image on (a) the exposure time, (b) multiple exposures, (c) the distance between object and slit camera, and (d) the width of the slit. At the end, the significant advantages of the presented X-ray backscatter camera in the context of aviation and port security are discussed. KW - Inspection with x-rays KW - Detection of explosives KW - Compton imaging KW - Detection of defects PY - 2013 DO - https://doi.org/10.1088/1748-0221/8/09/P09017 SN - 1748-0221 VL - 8 IS - 9 SP - P09017-1 EP - P09017-18 PB - Inst. of Physics Publ. CY - London AN - OPUS4-29329 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Haith, M. I. A1 - Ewert, Uwe A1 - Hohendorf, Stefan A1 - Bellon, Carsten A1 - Deresch, Andreas A1 - Huthwaite, P. A1 - Lowe, M. J. S. A1 - Zscherpel, Uwe T1 - Modelling based radiography for NDE of subsea pipelines N2 - This work presents the use of limited experimental measurements to develop a set of calibrated Simulation parameters that can then be used for reliable simulation of subsea pipeline inspections. The modelling software aRTist is used as the simulation tool, and the calibration is through comparison with experimental images of a well characterised sample in a water tank. Image Quality parameters such as signal-to-noise ratio, contrast and basic spatial resolution are compared with the aim of matching simulated values to experimental results. Currently the model is partially calibrated, with signal-to-noise ratio successfully matched while differences are still found in contrast-to-noise ratio comparisons. This means that measurements depending on absolute intensity are not accurate enough in the simulation at this stage. However, the simulation is found to be accurate for wall thickness measurements in tangential images, which are not based on absolute intensity, with simulated and experimental cases producing similar results. T2 - 42nd Annual Review of Progress CY - Minneapolis, Minnesota, USA DA - 26.07.2015 KW - Modelling KW - Radiography KW - Pipeline inspection KW - Nondestructive evaluation PY - 2016 SN - 978-0-7354-1353-5 DO - https://doi.org/10.1063/1.4940575 SN - 0094-243X VL - 1706 SP - 110004-1 EP - 110004-8 PB - AIP Publishing AN - OPUS4-37553 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe A1 - Redmer, Benrhard A1 - Schumacher, David A1 - Thiessenhusen, Kai-Uwe A1 - Bellon, Carsten A1 - Nicholson, P. I. A1 - Clarke, A. L. A1 - Finke-Härkönen, K.-P. T1 - X-ray tomographic in-service inspection of girth welds – the european project tomoweld N2 - The new standard ‘ISO 17636-2:2013: Non-destructive testing of welds — Radiographic testing — Part 2: X- and gamma-ray techniques with digital detectors’, defines the practice for radiographic inspection of welded pipes for manufacturing and in-service inspection. It is applied in Europe for inspections of pipe welds in nuclear power plants as well as in chemical plants and allows a faster inspection with digital detector arrays (DDA) than with film. Nevertheless, it does not allow the evaluation of the depth and shape of volumetric and planar indications. In 2001 a planar tomography scanner, TomoCAR, was introduced for mechanized radiographic testing (RT) inspection and non-destructive measurement of cross sections. The project TomoWELD is based on a new concept of the scan geometry, an enhanced GPU based reconstruction, and the application of a new generation of photon counting DDAs based on CdTe crystal CMOS hybrids. The new detector permits the selection of energy thresholds to obtain an optimum energy range and reduction of the influence of scattered radiation. The concept and first measurements are presented. Flaw depth and shape of volumetric and planar irregularities can be determined. T2 - QNDE 2014 CY - Boise, Idaho, USA DA - 20.07.2014 KW - X-ray imaging KW - Tomography KW - Engineering inspection KW - Radiography KW - Welded joints KW - Chemical plants PY - 2015 SN - 978-0-7354-1292-7 DO - https://doi.org/10.1063/1.4914650 SN - 0094-243X N1 - Geburtsname von Schumacher, David: Walter, D. - Birth name of Schumacher, David: Walter, D. VL - 1650 SP - 525 EP - 533 PB - American Institute of Physics AN - OPUS4-36581 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Christina A1 - Zscherpel, Uwe A1 - Ewert, Uwe A1 - Rosenthal, Martina A1 - Bellon, Carsten A1 - Jaenisch, Gerd-Rüdiger ED - Madalgue, X. P. V. T1 - Reliability investigation of NDE signals N2 - The reliability investigations are dedicated to throw light on the performance of the NDE system with respect to the required aim. This is especially of interest when digitized and processed signals are involved where it becomes hard to assess whether the quality of the system has raised or not. Three different ways to investigate reliability of NDE signals will be described. The first way of investigation, the performance demonstration, is preferred e.g. in the US American nuclear power industry. This is an integral consideration of the non destructive test as a system where the whole NDE system is packed in a black box and only the input in terms of the real existing flaws in the component is considered and compared to the output in terms of the indications of the human inspector or of the automated system. The second – the European tradition – relies on a standardized description of physical/technical parameters of the NDE system which are preconditions for successful system performance. An example for such a standardized set of performance parameters is given in the recently released standard about Xray film digitization CEN EN 14096. The third approach – the modular conception – is a marriage of both: The signal chain is cut into main modules. Each module is assessed in a most appropriate individual way e.g. via modeling calculations. The single results are joint together according to the reliability of the subsystems. Separating criteria for the system were proposed through a reliability formula developed during a series of European-American workshops on NDE reliability. Examples of all three approaches will be given. T2 - 4th International Workshop - Advances in Signal Processing for Nondestructive Evaluation of Materials CY - Québec, Canada DA - 2001-08-07 KW - Reliability of NDE Systems KW - Performance Demonstration KW - Essential Parameters KW - European Standards KW - Radiographic Testing KW - Film Digitalization KW - Austenitic Tube Welds KW - ROC KW - POD PY - 2002 UR - http://intl.gel.ulaval.ca/image_site/abs_quebec_01.pdf SN - 1-571-17091-X N1 - Geburtsname von Rosenthal, Martina: Scharmach, M. - Birth name of Rosenthal, Martina: Scharmach, M. N1 - Geburtsname von Jaenisch, Gerd-Rüdiger: Tillack, G.-R. - Birth name of Jaenisch, Gerd-Rüdiger: Tillack, G.-R. N1 - Serientitel: Topics on nondestructive evaluation series – Series title: Topics on nondestructive evaluation series IS - 6 SP - 61 EP - 72 PB - American Society for Nondestructive Testing CY - Columbus, Ohio AN - OPUS4-2007 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Christina A1 - Elagin, Mstislav A1 - Bellon, Carsten A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Rosenthal, Martina A1 - Redmer, Bernhard A1 - Ryden, H. A1 - Ronneteg, U. ED - Proske, D. T1 - Probability-of-Detection-Evaluation of NDT Techniques for Cu-Canisters for Risk Assessment of Nuclear Waste Encapsulation T2 - 4th International Probabilistic Symposium CY - Berlin, Germany DA - 2006-10-12 KW - Zerstörungsfreie Prüfung KW - Zuverlässigkeit KW - POD KW - Endlagerung radioaktiver Abfälle PY - 2006 SN - 3-00-019232-8 N1 - Geburtsname von Rosenthal, Martina: Scharmach, M. - Birth name of Rosenthal, Martina: Scharmach, M. SP - 227 EP - 252 PB - Bundesanstalt für Materialforschung und -prüfung CY - Berlin AN - OPUS4-14418 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Christina A1 - Elagin, Mstislav A1 - Bellon, Carsten A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Rosenthal, Martina A1 - Redmer, Bernhard A1 - Ryden, H. A1 - Ronneteg, U. T1 - POD (Probability of Detection) Evaluation of NDT Techniques for Cu-Canisters for Risk Assessment of Nuclear Waste Encapsulation T2 - 9th European Conference on NDT CY - Berlin, Germany DA - 2006-09-25 KW - Zerstörungsfreie Prüfung KW - Zuverlässigkeit KW - POD KW - Endlagerung radioaktiver Abfälle PY - 2006 SN - 3-931381-86-2 N1 - Geburtsname von Rosenthal, Martina: Scharmach, M. - Birth name of Rosenthal, Martina: Scharmach, M. SP - 1(?) EP - 22(?) PB - European Federation for Non-Destructive Testing CY - Berlin AN - OPUS4-14419 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Christina A1 - Elagin, Mstislav A1 - Bellon, Carsten A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Rosenthal, Martina A1 - Redmer, Bernhard A1 - Ryden, H. A1 - Ronneteg, U. T1 - Reliability evaluation of NDT techniques for Cu-welds for risk assessment of nuclear waste encapsulation KW - Zerstörungsfreie Prüfung KW - Zuverlässigkeit KW - POD KW - Endlagerung radioaktiver Abfälle PY - 2006 SN - 0025-5300 N1 - Geburtsname von Rosenthal, Martina: Scharmach, M. - Birth name of Rosenthal, Martina: Scharmach, M. VL - 48 IS - 3 SP - 111 EP - 117 PB - Carl Hanser Verlag CY - München AN - OPUS4-14421 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Christina A1 - Elagin, Mstislav A1 - Bellon, Carsten A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Scharmach, M. A1 - Redmer, Bernhard A1 - Ryden, H. A1 - Ronneteg, U. ED - Bièth, M. ED - Whittle, J. T1 - POD (Probability of Detection) Evaluation of NDT Techniques for Cu-Canisters for Risk Assessment of Nuclear Waste Encapsulation T2 - 5th International Conference on NDE in Relation to Structural Integrity for Nuclear and Pressurised Components CY - San Diego, CA, USA DA - 2006-05-10 KW - Zerstörungsfreie Prüfung KW - Zuverlässigkeit KW - POD PY - 2007 SN - 978-92-79-06107-3 SN - 1018-5593 N1 - Serientitel: JRC Scientific and Technical Reports – Series title: JRC Scientific and Technical Reports IS - Paper 1005 SP - 274 EP - 295 PB - Office for Official Publications of the European Communities CY - Luxembourg AN - OPUS4-15887 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ewert, Uwe A1 - Beckmann, Jörg A1 - Bellon, Carsten A1 - Jaenisch, Gerd-Rüdiger A1 - Zscherpel, Uwe A1 - Jechow, Mirko T1 - Fehlergrößenabhängige Kontrastreduktion und zusätzliche Unschärfe durch Streustrahlung - Film und digitale Detektoren im Vergleich N2 - Die radiografische Bildqualität in ihrer klassischen Definition hängt von Kontrast, Rauschen und Unschärfe ab. Diese Parameter werden normalerweise mit Bildgüteprüfkörpern (BPK) bestimmt. Die Streustrahlung reduziert im Allgemeinen immer die Bildqualität in der Radiografie. Verschiedene Einflussgrößen werden unter Berücksichtigung von Techniken, wie Film-Radiografie, Computer-Radiografie mit Speicherfolien und digitale Radiographie mit Matrixdetektoren, analysiert. In Lehrbüchern und Standards werden das Streuverhältnis k und verschiedene Kontraste definiert. Für digitale Medien werden zusätzliche Parameter wie das Signal-Rausch-Verhältnis SNR und das Kontrast-Rausch-Verhältnis CNR eingeführt. In diesem Zusammenhang wird der Einfluss der Streustrahlung aus dem Messobjekt und dem Detektor bestehend aus Kassette bzw. Gehäuse und sensitiver Detektorschicht auf die Bildqualität ermittelt. Die numerische Modellierung wird eingesetzt, um die Streustrahlung und die Primärstrahlung aus dem Objekt separat zu bestimmen. Die Streustrahlung aus dem Objekt und Detektor erzeugen eine Abbildung des Objektes, die dem Primärstrahlungsbild überlagert ist, wobei das Streubild eine höhere Unschärfe aufweist. Dieser Effekt hängt von der Fehlergröße, dem Abstand zwischen Detektor und Objekt und der Zwischenfilterung ab. KW - Digitale Radiologie KW - Kontrast-Rausch-Verhältnis KW - Streuverhältnis KW - Röntgen Simulation PY - 2008 SN - 0025-5300 VL - 50 IS - 10 SP - 560 EP - 568 PB - Hanser CY - München AN - OPUS4-18346 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zscherpel, Uwe A1 - Alekseychuk, Oleksandr A1 - Bellon, Carsten A1 - Ewert, Uwe A1 - Rost, P. A1 - Schmid, M. T1 - Korrosionsmapping an Rohrleitungen T2 - DGZfP-JAHRESTAGUNG 2002 CY - Weimar, Germany DA - 2002-05-06 PY - 2002 AN - OPUS4-19974 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Haith, M. I. A1 - Ewert, Uwe A1 - Hohendorf, Stefan A1 - Bellon, Carsten A1 - Deresch, Andreas A1 - Huthwaite, P. A1 - Lowe, M. J. S. A1 - Zscherpel, Uwe T1 - Radiographic modelling for NDE of subsea pipelines N2 - This work presents an investigation of the accuracy of a radiographic simulation model applied to subsea pipeline inspections. Experimental measurements of a sample in a water tank are used to develop a set of calibrated simulation parameters for the modelling software aRTist. Image quality parameters such as signal-tonoise ratio, contrast and basic spatial resolution are compared with the aim of matching simulated values to experimental results. With this method signal-to-noise ratio was successfully matched while differences were still found in contrast-to-noise ratio comparisons. This means that measurements depending on absolute intensity are not accurate enough, however wall thickness measurements in tangential images, which are not based on absolute intensity, were found to produce similar results in simulated and experimental cases. The differences in contrast and intensity are thought to be due to detector backscatter and additional scatter from out-of-setup objects within the exposure bay, due to a lack of source collimation. These would affect the experimental results but were not included in the simulated setup. This was investigated by including different proportions of peripheral water and other objects in the modelled setup and examining the effect on Image quality parameters. Results show that this additional scatter has a significant impact on the radiograph, particularly on image contrast, and is therefore the likely cause of differences between experimental and simulated images. This implies that it will be very difficult to completely match simulated to experimental results, as including all possible scattering objects in the model would be very complex. An improvement could be made by using real subsea data to estimate this additional scattering, which could then be used to calibrate the model. However there would still be significant uncertainty in the ability of the model to accurately produce realistic intensity and contrast. KW - Digital radiography KW - Modelling validation KW - Subsea pipeline inspection KW - Tangential radiography PY - 2017 DO - https://doi.org/10.1016/j.ndteint.2016.11.006 SN - 0963-8695 SN - 1879-1174 VL - 86 SP - 113 EP - 122 AN - OPUS4-39053 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Boateng, Francis Twumasi A1 - Ewert, Uwe A1 - Kannengießer, Thomas A1 - Zscherpel, Uwe A1 - Griesche, Axel A1 - Kromm, Arne A1 - Hohendorf, Stephan A1 - Redmer, Bernard T1 - Real-time radiography for observation of crack growth during GTA (Gas Tungsten Arc) welding N2 - In situ crack detection in the mushy zone and the solid weld of a gas tungsten arc (GTA) weld using X-ray imaging during welding is a new research area for NDT inspection. Usually, NDT flaw detection is done after the complete solidification of the weld seam. In this paper, we present the use of real-time radiography with a minifocus X-ray source (YXLON X-ray tube Y.TU 225-D04) and a 75μm pixel size digital detector array (Dexela 1512) for the acquisition of 2D radiographic images by a sequence of exposures with time intervals of 80 ms for hot crack detection during single pass bead-on-plate GTA welding of 3 mm thick plates of aluminium alloy AlMgSi (6060). An analysis of the crack distribution in the weld sample is conducted from the acquired 2D radiographs and its corresponding 3D volumetric reconstruction achieved by linear coplanar digital laminography. This in situ approach opens new possibilities in the field of hot crack research by having the direct information of both the crack initiation and growth and its correlation to the welding parameters. KW - Hot cracking KW - Radiography KW - GTA welding KW - Aluminium alloys KW - Real-time operation PY - 2016 DO - https://doi.org/10.1007/s40194-016-0351-7 SN - 0043-2288 SN - 1878-6669 VL - 60 IS - 5 SP - 931 EP - 937 AN - OPUS4-37128 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Osterloh, Kurt A1 - Bücherl, T. A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Image recovery by removing stochastic artefacts identified as local asymmetries N2 - Stochastic artefacts are frequently encountered in digital radiography and tomography with neutrons. Most obviously, they are caused by ubiquitous scattered radiation hitting the CCD-sensor. They appear as scattered dots and, at higher frequency of occurrence, they may obscure the image. Some of these dotted interferences vary with time, however, a large portion of them remains persistent so the problem cannot be resolved by collecting stacks of images and to merge them to a median image. The situation becomes even worse in computed tomography (CT) where each artefact causes a circular pattern in the reconstructed plane. Therefore, these stochastic artefacts have to be removed completely and automatically while leaving the original image content untouched. A simplified image acquisition and artefact removal tool was developed at BAM and is available to interested users. Furthermore, an algorithm complying with all the requirements mentioned above was developed that reliably removes artefacts that could even exceed the size of a single pixel without affecting other parts of the image. It consists of an iterative two-step algorithm adjusting pixel values within a 3 × 3 matrix inside of a 5 × 5 kernel and the centre pixel only within a 3 × 3 kernel, resp. It has been applied to thousands of images obtained from the NECTAR facility at the FRM II in Garching, Germany, without any need of a visual control. In essence, the procedure consists of identifying and tackling asymmetric intensity distributions locally with recording each treatment of a pixel. Searching for the local asymmetry with subsequent correction rather than replacing individually identified pixels constitutes the basic idea of the algorithm. The efficiency of the proposed algorithm is demonstrated with a severely spoiled example of neutron radiography and tomography as compared with median filtering, the most convenient alternative approach by visual check, histogram and power spectra analysis. KW - Data processing methods KW - Image filtering KW - Pattern recognition KW - Cluster finding KW - Calibration and fitting methods PY - 2012 DO - https://doi.org/10.1088/1748-0221/7/04/C04018 SN - 1748-0221 VL - 7 IS - April SP - 1 EP - 14 PB - Inst. of Physics Publ. CY - London AN - OPUS4-25877 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Digitale industrielle Radiographie im Anlagenbau N2 - Der Ersatz von Röntgenfilmen durch digitale Detektoren in der Zerstörungsfreien Prüfung im Anlagenbau wird seit 2013 durch neue ISO-Normen unterstützt. Nach der Erfolgsgeschichte der digitalen Photographie und der fast vollständigen Ablösung der Filmtechnik in der optischen Bilderfassung wird erwartet, dass sich der Übergang von der Filmradiographie zur digitalen Radiographie schnell vollzieht. Dieser Trend ist derzeit so noch nicht zu beobachten. Zur mobilen Prüfung wird in Europa immer noch vorrangig die Filmradiographie und nur teilweise die Computerradiographie mit Speicherfolien eingesetzt. Im Bereich der stationären Prüftechnik haben sich die Matrixdetektoren (DDA) weitgehend durchgesetzt, wobei es auch hier noch alternative Detektoren wie Bildverstärker und Fluoroskope gibt. Mit Einführung der DIN EN ISO 17636-2 zur Schweißnahtprüfung wird seit 2013 erstmalig geregelt, wie man einen digitalen Detektor für die technische Radiographie auswählen soll, um im Vergleich zur Filmradiographie eine äquivalente Bildqualität zu erhalten. Essentielle Parameter bestimmen, ob die geforderte Bildgüte (Fehlernachweißempfindlichkeit) erreicht wird. Ein Überblick zeigt, welche Parameter für den praktischen Einsatz wichtig sind und wie sie ermittelt werden. Praktische Einsatzbeispiele im Anlagenbau werden diskutiert. T2 - 47. Sondertagung: Schweißen im Anlagen- und Behälterbau CY - Munich, Germany DA - 19.02.2019 KW - Industrielle Radiographie KW - Digitaler Filmersatz KW - Stand der Normung KW - Bildqualitätsnachweis PY - 2019 SN - 978-3-96144-055-9 VL - 350 SP - 19 EP - 22 PB - DVS Media CY - Düsseldorf AN - OPUS4-50526 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Aktuelle Entwicklungen in der Standardisierung N2 - In den letzten zwei Jahren wurden 11 neue Standards/Standardrevisionen zur RT veröffentlicht (ohne Strahlenschutz) und 5 werden dafür gestrichen. Es wird über die neuen Anforderungen ausgewählter Normen bzw. Normrevisionen informiert und insbesondere auch über die veränderten Parameter, die bei Prüfpraxis und bei der Klassifizierung zu berücksichtigen sind. Das wichtigste Projekt ist die Revision der DIN EN ISO 17636-1, -2, RT von Schweißverbindungen, in ISO TC 44 SC 5 WG 1. Die Standards zur Schweißnahtprüfung in der Kerntechnik, DIN 25435, wurden ins Englische übertragen und bei ISO TC 85 SC 6 bearbeitet. Hauptaktivität bei ASTM ist gegenwärtig die Überarbeitung der CT-Standards und die Berücksichtigung der Anforderungen an das dimensionelle Messen. Der Guide ASTM E 1441 zur Bestimmung von MTF, Kontrast-Detail-Funktion (CDF) und Kontrast-Diskrimination-Diagramm (CDD) wird revidiert. E 2445 zur CR Long Term Stability wird ebenfalls revidiert. Die Revision soll auch in die ISO 16371-1 eingehen. Dazu ist ein Round Robin-Test geplant. Auch die Standards zur Durchstrahlungsprüfung auf Korrosion und Ablagerungen in Rohren mit Röntgen- und Gammastrahlen (EN 16407-1, -2, 2014) wurden revidiert. Diese Revision wurde als DIN EN ISO 20769-1, -2 2018 veröffentlicht und EN 16407 wird zurückgezogen. Die Revision der Standards EN 12543 und EN 12679 zur Messung der Brennfleckgröße und der Strahlergröße ist mit Verzögerung in Überarbeitung, um die digitalen Detektoren und Messmöglichkeiten mit Bildverarbeitungsprogrammen zu berücksichtigen. Ein Entwurf zur Messung der Brennfleckgröße von nano-Fokusröhren wird derzeit vom Europäischen Metrologie-Programm EMPIR gefördert. Zur radiographischen Gussteilprüfung wurde der Standard EN 12681 revidiert und 2018 veröffentlicht. Er wurde um Zulässigkeitsgrenzen erweitert und die digitale Radiographie wurde in Teil 2 berücksichtigt. T2 - 17. Seminar der DGZfP "Aktuelle Fragen der Durchstrahlungsprüfung und des Strahlenschutzes" CY - Kassel, Germany DA - 28.03.2019 KW - Digitale Radiographie KW - Standards KW - Bildqualität KW - Klassifizierung PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-505371 UR - https://www.ndt.net/search/docs.php3?id=24807 VL - 24 IS - 12 SP - 1 EP - 5 PB - NDT.net CY - Kirchwald AN - OPUS4-50537 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -