TY - JOUR A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Electronic reference images for flaw indications in welds and castings N2 - Since decades the evaluation of flaw indications on radiographs from welds or castings are based on well accepted reference film catalogues from organizations like IIW (weldments), ASTM (castings) or DGZfP (D5 recommendation on heavy steel castings). Today, the transformation of classical film radiography to the digital world is in full progress. Some ASTM standards do not permit the evaluation of digital radiographs in reference to film catalogues. Therefore, these reference film catalogues have to be converted into the digital age too. BAM is supporting this transition by high definition film scanning. The result is a corresponding reference image catalogue. The different standard organizations selected different ways to distribute the digital data. ASTM used high definition film scanning at 10 μm pixel size and distribution of a huge amount of high-res data via DVD. The user sub-samples these high-res data during catalogue import to the resolution of his system. The comparison is done by synchronized image viewing on the computer work station. IIW recently decided to distribute their ISO 5817 reference images installed on tablets, which are used for image viewing too. The tablet image has to be compared with the digital image on the system monitor. DGZfP transformed their D5 reference radiographs into a PDF for monitor viewing. This is the simplest and cheapest solution, but still allows the full usage of the catalogue in the digital era. The status of ongoing work in progress will be discussed. T2 - WCNDT 2016 CY - Munich, Germany DA - 13.06.2016 KW - Castings KW - NDT KW - RT KW - Radiography KW - Discontinuities KW - Catalogues KW - Welds PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-377306 UR - http://ndt.net/?id=19310 SN - 1435-4934 VL - 21 IS - 7 SP - 1 EP - 8 PB - NDT.net CY - Kirchwald AN - OPUS4-37730 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Filmersatz in der radiographischen Schweißnahtprüfung: Neue ISO-Standards und Erfahrungen im praktischen Einsatz digitaler Detektoren N2 - Der Ersatz von Röntgenfilmen durch digitale Detektoren in der zerstörungsfreien Prüfung wurde in den letzten 10 Jahren kontrovers diskutiert. Nach der Erfolgsgeschichte der digitalen Photographie und der fast vollständigen Ablösung der Filmtechnik in der optischen Bilderfassung wurde erwartet, dass sich der Übergang von der Filmradiographie zur digitalen Radiographie schnell vollziehen sollte. Dieser Trend ist derzeit so noch nicht zu beobachten. Zur mobilen Prüfung wird in Europa immer noch vorrangig die Filmradiographie und nur teilweise die Speicherfolientechnik eingesetzt. Im Bereich der stationären Prüftechnik haben sich die Matrixdetektoren (DDA) weitgehend durchgesetzt, wobei es auch hier noch alternative Detektoren wie Bildverstärker und Fluoroskope gibt. Mit Einführung der DIN EN ISO 17636-2 wird seit 2013 erstmalig geregelt, wie man einen digitalen Detektor für die technische Radiographie auswählen soll, um im Vergleich zur Filmradiographie eine äquivalente Bildqualität zu erhalten. Essentielle Parameter bestimmen, ob die geforderte Bildgüte erreicht werden kann. Es wird ein Überblick gegeben, welche Parameter zum praktischen Einsatz wichtig sind und wie sie ermittelt werden. Erste Erfahrungen im praktischen Einsatz werden diskutiert. T2 - Sondertagung "Schweissen im Anlagen- und Behälterbau" 2016 CY - Munich, Germany DA - 23.02.2016 KW - Welds KW - RT KW - Radiography KW - NDT KW - Discontinuities KW - Catalogues KW - Zerstörungsfreie Prüfung KW - Praktische Erfahrungen KW - Standardisierung KW - Durchstrahlungsprüfung KW - Filmersatz durch digitale Detektoren PY - 2016 SN - 978-3-945023-59-4 VL - 322 SP - 55 EP - 58 PB - DVS Media CY - Düsseldorf AN - OPUS4-37733 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zscherpel, Uwe A1 - Ewert, Uwe A1 - Jechow, Mirko ED - Thompson, D. O. ED - Chimenti, D. E. T1 - Concepts for evaluation of image quality in digital radiology N2 - Concepts for digital image evaluation are presented for Computed Radiography (CR) and Digital Detector Arrays (DDAs) used for weld inspection. The precise DDA calibration yields an extra ordinary increase of contrast sensitivity up to 10 times in relation to film radiography. Restrictions in spatial resolution caused by pixel size of the DDA are compensated by increased contrast sensitivity. First CR standards were published in 2005 to support the application of phosphor imaging plates in lieu of X-ray film, but they need already a revision based on experiences reported by many users. One of the key concepts is the usage of signal-to-noise (SNR) measurements as equivalent to the optical density of film and film system class. The contrast sensitivity, measured by IQI visibility, depends on three essential parameters: The basic spatial resolution (SRb) of the radiographic image, the achieved signal-to-noise ratio (SNR) and the specific contrast (µeff - effective attenuation coefficient). Knowing these 3 parameters for the given exposure condition, inspected material and monitor viewing condition permits the calculation of the just visible IQI element. Furthermore, this enables the optimization of exposure conditions. The new ISO/FDIS 17636-2 describes the practice for digital radiography with CR and DDAs. It considers the first time compensation principles, derived from the three essential parameters. The consequences are described. T2 - 38th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Burlington, VT, USA DA - 17.07.2011 KW - Image resolution KW - Inspection KW - Production engineering computing KW - Radiography KW - Welding KW - X-ray imaging KW - ZfP KW - Radiographie KW - Bildqualität KW - Filmersatz KW - Digitale Detektoren PY - 2012 SN - 978-0-7354-1013-8 DO - https://doi.org/10.1063/1.4716281 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings IS - 1430 SP - 589 EP - 596 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-26697 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Beckmann, Jörg A1 - Bavendiek, K. T1 - Digital radiography - Films and digital detectors in comparison T2 - MINDTCE `09 - Malaysia international NDT conference and exhibiton `09 - NDT Driving industry safety, growth and performance CY - Kuala Lumpur, Malaysia DA - 2009-07-20 KW - Radiography KW - Film replacement KW - Computed radiography KW - Imaging plates KW - Digital detector arrays KW - Contrast sensitivity KW - SNR KW - standards PY - 2009 SP - 181 EP - 189 AN - OPUS4-20253 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ewert, Uwe A1 - Bavendiek, K. A1 - Robbins, J. A1 - Zscherpel, Uwe A1 - Bueno, C. A1 - Gordon, T. A1 - Mishra, D. T1 - New compensation principles for enhanced image quality in industrial radiology with digital detector arrays KW - Radiography KW - Film replacement KW - Digital detector arrays KW - Contrast sensitivity KW - SNR KW - CNR KW - Spatial resolution KW - Bad pixels KW - Standards KW - Compensation principles PY - 2010 SN - 0025-5327 VL - 68 IS - 2 SP - 163 EP - 168 PB - Society for Nondestructive Testing CY - Columbus, Ohio AN - OPUS4-22538 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Osterloh, Kurt A1 - Bücherl, T. A1 - Lierse von Gostomski, C. A1 - Zscherpel, Uwe A1 - Ewert, Uwe A1 - Bock, S. T1 - Filtering algorithm for dotted interferences N2 - An algorithm has been developed to remove reliably dotted interferences impairing the perceptibility of objects within a radiographic image. This particularly is a major challenge encountered with neutron radiographs collected at the NECTAR facility, Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II): the resulting images are dominated by features resembling a snow flurry. These artefacts are caused by scattered neutrons, gamma radiation, cosmic radiation, etc. all hitting the detector CCD directly in spite of a sophisticated shielding. This makes such images rather useless for further direct evaluations. One approach to resolve this problem of these random effects would be to collect a vast number of single images, to combine them appropriately and to process them with common image filtering procedures. However, it has been shown that, e.g. median filtering, depending on the kernel size in the plane and/or the number of single shots to be combined, is either insufficient or tends to blur sharp lined structures. This inevitably makes a visually controlled processing image by image unavoidable. Particularly in tomographic studies, it would be by far too tedious to treat each single projection by this way. Alternatively, it would be not only more comfortable but also in many cases the only reasonable approach to filter a stack of images in a batch procedure to get rid of the disturbing interferences. The algorithm presented here meets all these requirements. It reliably frees the images from the snowy pattern described above without the loss of fine structures and without a general blurring of the image. It consists of an iterative, within a batch procedure parameter free filtering algorithm aiming to eliminate the often complex interfering artefacts while leaving the original information untouched as far as possible. KW - Neutron KW - Radiography KW - Tomography KW - Filtering KW - Evaluation KW - NECTAR PY - 2011 DO - https://doi.org/10.1016/j.nima.2011.01.107 SN - 0168-9002 SN - 0167-5087 VL - 651 IS - 1 SP - 171 EP - 174 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-24917 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Haith, M. I. A1 - Ewert, Uwe A1 - Hohendorf, Stefan A1 - Bellon, Carsten A1 - Deresch, Andreas A1 - Huthwaite, P. A1 - Lowe, M. J. S. A1 - Zscherpel, Uwe T1 - Modelling based radiography for NDE of subsea pipelines N2 - This work presents the use of limited experimental measurements to develop a set of calibrated Simulation parameters that can then be used for reliable simulation of subsea pipeline inspections. The modelling software aRTist is used as the simulation tool, and the calibration is through comparison with experimental images of a well characterised sample in a water tank. Image Quality parameters such as signal-to-noise ratio, contrast and basic spatial resolution are compared with the aim of matching simulated values to experimental results. Currently the model is partially calibrated, with signal-to-noise ratio successfully matched while differences are still found in contrast-to-noise ratio comparisons. This means that measurements depending on absolute intensity are not accurate enough in the simulation at this stage. However, the simulation is found to be accurate for wall thickness measurements in tangential images, which are not based on absolute intensity, with simulated and experimental cases producing similar results. T2 - 42nd Annual Review of Progress CY - Minneapolis, Minnesota, USA DA - 26.07.2015 KW - Modelling KW - Radiography KW - Pipeline inspection KW - Nondestructive evaluation PY - 2016 SN - 978-0-7354-1353-5 DO - https://doi.org/10.1063/1.4940575 SN - 0094-243X VL - 1706 SP - 110004-1 EP - 110004-8 PB - AIP Publishing AN - OPUS4-37553 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe A1 - Redmer, Benrhard A1 - Schumacher, David A1 - Thiessenhusen, Kai-Uwe A1 - Bellon, Carsten A1 - Nicholson, P. I. A1 - Clarke, A. L. A1 - Finke-Härkönen, K.-P. T1 - X-ray tomographic in-service inspection of girth welds – the european project tomoweld N2 - The new standard ‘ISO 17636-2:2013: Non-destructive testing of welds — Radiographic testing — Part 2: X- and gamma-ray techniques with digital detectors’, defines the practice for radiographic inspection of welded pipes for manufacturing and in-service inspection. It is applied in Europe for inspections of pipe welds in nuclear power plants as well as in chemical plants and allows a faster inspection with digital detector arrays (DDA) than with film. Nevertheless, it does not allow the evaluation of the depth and shape of volumetric and planar indications. In 2001 a planar tomography scanner, TomoCAR, was introduced for mechanized radiographic testing (RT) inspection and non-destructive measurement of cross sections. The project TomoWELD is based on a new concept of the scan geometry, an enhanced GPU based reconstruction, and the application of a new generation of photon counting DDAs based on CdTe crystal CMOS hybrids. The new detector permits the selection of energy thresholds to obtain an optimum energy range and reduction of the influence of scattered radiation. The concept and first measurements are presented. Flaw depth and shape of volumetric and planar irregularities can be determined. T2 - QNDE 2014 CY - Boise, Idaho, USA DA - 20.07.2014 KW - X-ray imaging KW - Tomography KW - Engineering inspection KW - Radiography KW - Welded joints KW - Chemical plants PY - 2015 SN - 978-0-7354-1292-7 DO - https://doi.org/10.1063/1.4914650 SN - 0094-243X N1 - Geburtsname von Schumacher, David: Walter, D. - Birth name of Schumacher, David: Walter, D. VL - 1650 SP - 525 EP - 533 PB - American Institute of Physics AN - OPUS4-36581 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Boateng, Francis Twumasi A1 - Ewert, Uwe A1 - Kannengießer, Thomas A1 - Zscherpel, Uwe A1 - Griesche, Axel A1 - Kromm, Arne A1 - Hohendorf, Stephan A1 - Redmer, Bernard T1 - Real-time radiography for observation of crack growth during GTA (Gas Tungsten Arc) welding N2 - In situ crack detection in the mushy zone and the solid weld of a gas tungsten arc (GTA) weld using X-ray imaging during welding is a new research area for NDT inspection. Usually, NDT flaw detection is done after the complete solidification of the weld seam. In this paper, we present the use of real-time radiography with a minifocus X-ray source (YXLON X-ray tube Y.TU 225-D04) and a 75μm pixel size digital detector array (Dexela 1512) for the acquisition of 2D radiographic images by a sequence of exposures with time intervals of 80 ms for hot crack detection during single pass bead-on-plate GTA welding of 3 mm thick plates of aluminium alloy AlMgSi (6060). An analysis of the crack distribution in the weld sample is conducted from the acquired 2D radiographs and its corresponding 3D volumetric reconstruction achieved by linear coplanar digital laminography. This in situ approach opens new possibilities in the field of hot crack research by having the direct information of both the crack initiation and growth and its correlation to the welding parameters. KW - Hot cracking KW - Radiography KW - GTA welding KW - Aluminium alloys KW - Real-time operation PY - 2016 DO - https://doi.org/10.1007/s40194-016-0351-7 SN - 0043-2288 SN - 1878-6669 VL - 60 IS - 5 SP - 931 EP - 937 AN - OPUS4-37128 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schumm, A. A1 - Martin, E. A1 - Beaumont, M. A1 - Ewert, Uwe A1 - Kolkoori, Sanjeevareddy A1 - Zscherpel, Uwe A1 - Wrobel, Norma A1 - Redmer, Bernhard T1 - A comparative study on the performance of digital detector systems for high energy applications N2 - For cast components reaching or exceeding total material thicknesses of 150mm, high energy sources such as linear accelerators or Betatrons are required in order to obtain reasonable exposure times. In this study, the performance of digital detector systems, involving imaging plates (IP) and digital detector arrays (DDA), was evaluated with respect to the testing class B requirements as formulated in the standard EN ISO 17636-2. As a reference, traditional radiographic film and a Cobalt-60 source was used. With film exposures, testing class B was achieved with Co-60 and Betatron (7.5 MV) at longer exposure times. The preliminary results show that the testing class B was not obtained with the examined digital detector arrays (DDA) and the high resolution imaging plates (IP) , even at 40, 60 and 80 minutes exposure time with a 7.5 MV Betatron. Class A was achieved using high resolution imaging plates with optimized metal filters between object and IPs and a high resolution DDA with intermediate Cu filters. Class A was also achieved applying a DDA with lower basic spatial resolution than required by Table B.13 of EN ISO 17636-2, but using the compensation principle as described in this standard. The next generation of digital detector arrays might potentially be able to obtain class B performance with the expected spatial resolution and sensitivity improvements. T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 06.10.2014 KW - Radiography KW - Image quality KW - Betatron KW - Digital detector array (DDA) KW - Casting KW - Standards KW - High energy radiography KW - Comparison of detectors KW - Steel weldment PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-323075 UR - https://www.ndt.net/?id=16394 SN - 1435-4934 VL - 19 IS - 12 SP - 1 EP - 6 PB - NDT.net CY - Kirchwald AN - OPUS4-32307 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wrobel, Norma A1 - Kolkoori, Sanjeevareddy A1 - Zscherpel, Uwe A1 - Ewert, Uwe T1 - Innovative X-ray backscatter technique for security applications: Detection of dangerous materials N2 - Radiological inspections, in general, are NDT&E methods to detect the bulk of explosives without invasion into the object of analysis. In contrast to personal luggage, cargo or structural components constitute a complexity that may significantly hamper the detection of a threat by conventional transmission radiography. A novel approach of interrogating a large object to a certain depth only with a single sided access will be presented. It consists of an X-ray backscatter camera with a special twisted slit collimator for imaging backscattered objects. The new X-ray backscatter camera is not only imaging the objects due to their densities but also by taking into account the influences of surrounding objects. Additionally, it does not only image illuminated features but also depicts shadows from absorbing materials. This is a unique characteristic of the developed X-ray backscatter camera. Experimental mock-ups are conducted imitating container with threats among a complex packing as they may be encountered in reality. At the end, the significant advantages of the presented X-ray backscatter camera in the context of aviation and port security will be discussed. T2 - ECNDT 2014 - 11th European conference on non-destructive testing CY - Prague, Czech Republic DA - 06.10.2014 KW - Radiography KW - X-ray backscatter imaging KW - Irradiation geometry KW - Detection of dangerous materials KW - Security applications PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-322429 UR - https://www.ndt.net/?id=16432 SN - 1435-4934 VL - 19 IS - 12 SP - 1 EP - 8 PB - NDT.net CY - Kirchwald AN - OPUS4-32242 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pitkänen, J. A1 - Bertovic, Marija A1 - Brackrock, Daniel A1 - Brekow, Gerhard A1 - Ewert, Uwe A1 - Kanzler, Daniel A1 - Müller, Christina T1 - Reliable evaluation of acceptability of weld for final disposal based on the canister copper weld inspection using different NDT methods N2 - The inspection of the sealing weld is an important phase for the evaluation of the acceptability of final disposal canister, but the weld is only a part of the 3D shielding of copper shell. The main tasks for reliable NDT evaluation requires an extensive evaluation of the parameters – which contains typical inspection related items like repeatability, S/N ratio, POD, setting up the equipment for inspection, and all practices for inspections. The other parameters are material parameters, their variation must be taken into account in the evaluation of NDT reliability. Further parameters include human factors, i. e. human inspectors and their interaction with technical systems; their effects were studied on an example of the evaluation of eddy current data. Final parameters are related to evaluation of detected defects, which means sizing and base for acceptance and this can be done in different ways. Some examples are given and results are compared with different methods for instance between radiographic testing and ultrasonic testing by raw data analysis and PA-SAFT results. Also, preliminary curves for the evaluation of metallographic results of 55 defects will be shown by EB weld measurements. Some practical items concerning copper inspections will be also discussed related to acceptability. N2 - Die Prüfung der Verschlussschweißnaht ist eine wichtige Phase in der Akzeptanzbewertung der Endlagerungskanister, obwohl die Verschlussschweißnaht nur ein Teil der dreidimensionalen Bedeckung der Kupfereinhüllung ist. Die Hauptaufgabe für die sichere zerstörungsfreie Prüfung (ZfP) erfordert eine umfangreiche Bewertung der Prüfparameter, die die typischen Prüfeinzelheiten, wie z. B. Wiederholbarkeit, Signal-Rausch-Verhältnis, POD, Einstellung der Geräte und alle Prüfvorgehen enthalten. Weitere Parameter sind die Schwankungen von Materialeigenschaften, die berücksichtigt werden müssen. Andere Parameter sind menschliche Faktoren, wie z. B. die Prüfer, und deren Interaktion mit den technischen Systemen, beispielsweise bei der Bewertung der Wirbelstromdaten. Weitere Einflussgrößen auf die Prüfung entstehen bei der Bewertung gefundener Fehler, bei der Größenbestimmung von Fehlern und basierend auf der strukturellen Integrität bei der Akzeptanz von definierten Fehlergrößen/Fehlerarten an verschiedenen Positionen in der Schweißnaht. Der Artikel zeigt einige Beispiele und den Vergleich zwischen verschiedenen ZfP-Methoden, z. B. der radiographische Prüfung, der Ultraschallprüfung mit Bewertung von Rohdaten und der Ultraschallprüfung mit Bewertung mittels PA-SAFT. Auch die vorläufigen Kurven für die metallographische Bewertung von 55 Fehlern der Elektronenstrahlschweißung sind gezeigt. Darüber hinaus wird auch eine praktische Vorgehensweise bei der Definition der Akzeptanzkriterien für die Kupferschweißnahtsprüfung diskutiert. KW - NDT reliability KW - Radiography KW - Ultrasonic testing KW - Eddy current testing KW - Visual testing PY - 2014 UR - http://www.hanser-elibrary.com/doi/pdf/10.3139/120.110609 DO - https://doi.org/10.3139/120.110609 SN - 0025-5300 VL - 56 IS - 9 SP - 748 EP - 757 PB - Hanser CY - München AN - OPUS4-31524 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Ewert, Uwe ED - Thompson, D. O. T1 - Reliability assessment by simulation for high energy radiography T2 - 33th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Portland, OR, USA DA - 2006-07-30 KW - Simulation KW - Radiography KW - CAD KW - Probability of Detection PY - 2007 SN - 978-0-7354-0399-4 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings IS - 894 SP - 1831 EP - 1838 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-15696 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Ewert, Uwe T1 - aRTist - Analytical RT Inspection Simulation Tool for Industrial Application T2 - 17th World Conference on Non-Destructive Testing CY - Shanghai, China DA - 2008-10-25 KW - Computer Simulation KW - Radiography KW - Computed Tomography KW - Ray Tracing PY - 2008 SP - 1 EP - 6 PB - International Committee for Non-Destructive Testing CY - Shanghai AN - OPUS4-18584 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Deresch, Andreas A1 - Bellon, Carsten A1 - Ewert, Uwe A1 - Przybilla, Waldemar ED - Thompson, D.O. ED - Chimenti, D.E. T1 - Measurement and modeling of scatter ratios at high energies N2 - Determining scatter ratios at high energies (> ~ 1MeV) presents challenges not immediately obvious from measurements at conventional X-ray energies. This includes reduced attenuation even in heavy elements as well as a stronger forward bias of scattering. In order to check the reliability of different measurement setups with regard to material thicknesses, distances, and collimation, attenuation and scattering were separately simulated using a Monte Carlo model. The simulation results help in understanding the sources of radiation scattered into the detection area, thereby aiding in eliminating undesired contributions. T2 - 37th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - San Diego, CA, USA DA - 18.07.2010 KW - Radiography KW - Optimisation KW - X-ray detection KW - Simulation KW - High energy KW - Co-60 KW - Modeling KW - Scatter PY - 2011 SN - 978-0-7354-0888-3 DO - https://doi.org/10.1063/1.3591895 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings IS - 1335 SP - 517 EP - 524 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-25358 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Deresch, Andreas A1 - Bellon, Carsten A1 - Jaenisch, Gerd-Rüdiger A1 - Ewert, Uwe ED - Chimenti, D.E. ED - Bond, L.J. T1 - Fast model of electron transport for radiographic spectrum simulation N2 - Correctly modeling the continuous photon spectrum of X-ray tubes requires detailed knowledge of the probability distribution of electron properties at the time of X-ray photon creation, in particular electron energy, depth within the target, and direction of movement. Semi-analytical X-ray spectrum models frequently assume a very simplified or even uniform distribution of electron direction. In the case of thick targets and small deviations from normal incidence this is a useful approximation. For thin targets or large deviations from normal incidence the correct distribution of electron directions becomes more important. As calculation speed is an important aspect of semi-analytical models compared to Monte Carlo simulations, fast evaluation of the distribution of electron properties is highly desirable. The approach presented here numerically evaluates the evolution of a discrete probability distribution of electron properties due to single electron scatter interactions within a plane target. This allows capturing the important aspects of the electron distribution while achieving runtimes of a few seconds up to a minute on a standard office PC. T2 - 41st Annual review of progress in quantitative nondestructive evaluation CY - Boise, Idaho, USA DA - 20.07.2014 KW - Radiography KW - Spectrum KW - Modeling KW - Valildation PY - 2015 SN - 978-0-7354-1292-7 DO - https://doi.org/10.1063/1.4914656 N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings VL - 1650 SP - 579 EP - 585 PB - AIP Publishing AN - OPUS4-33082 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -