TY - JOUR A1 - Even, Morgane A1 - Juritsch, Elevtheria A1 - Richter, Matthias T1 - Measurement of very volatile organic compounds (VVOCs) in indoor air by sorbent-based active sampling: Identifying the gaps towards standardisation N2 - The ISO 16000-6 standard describes a method for the determination of volatile organic compounds (VOCs) in indoor and test chamber air by sorbent-based active sampling, thermal desorption and gas chromatography coupled with mass spectrometry (GC/MS). It also gives directions to adapt this methodology to very volatile organic compounds (VVOCs). Indeed, toxicologically based guideline values are being implemented for these compounds and it becomes necessary to measure them. But a comprehensive and robust measurement method is lacking. This work highlights the points that still need to be explored towards the standardisation of a suitable procedure: investigations on sorbent combinations, the suitability of chromatography columns and the use of gaseous standards are required. The biggest challenge remains in the fact that strong sorbents adsorb water together with VVOCs. Water may impair the analysis and the optimal approach to eliminate it is still to be found and integrated into the sampling strategy. KW - Solvents KW - Air analysis KW - VOC KW - Thermal desorption KW - Gas chromatography KW - ISO 16000-6 PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-523919 DO - https://doi.org/10.1016/j.trac.2021.116265 VL - 140 SP - 116265 PB - Elsevier B.V. AN - OPUS4-52391 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Even, Morgane A1 - Juritsch, Elevtheria A1 - Richter, Matthias T1 - Selection of gas standards, gas chromatography column and adsorbents for the measurement of very volatile organic compounds (C1–C6) in indoor air N2 - The ISO 16000-6 standard gives directions to adapt the analysis of volatile organic compounds (VOCs) in indoor and test chamber air to very volatile organic compounds (VVOCs). The same techniques with sorbent-based active sampling, thermal desorption and gas chromatography coupled with mass spectrometry (TD-GC/MS) should be used. However, VVOCs require gaseous standards, an adapted GC column and a reliable sampling adsorbent. This work presents experimental results to tackle those three experimental gaps. A stable standard gas mixture containing 47 VVOCs, 13 VOCs and an internal standard was successfully generated. It was employed to study the suitability of seven types of chromatography columns. The use of PLOT (Porous Layer Open Tubular) columns such as PoraBOND Q is well suitable for VVOC analysis. The recoveries of the 60 analytes on a total of 16 adsorbents and their combinations were determined: A combination of the graphitized carbon black Carbograph 5TD 40/60 and the carbon molecular sieve CarbosieveTM SII showed great recoveries for all analytes. Carbon molecular sieves adsorb water which can impair the analysis. A dry purge of the multi-sorbent in the sampling direction led to a complete water removal and promising recoveries of the analytes. KW - VVOC KW - VOC KW - ISO 16000-6 KW - Gas chromatography KW - Thermal desorption KW - Air sampling PY - 2023 DO - https://doi.org/10.1016/j.aca.2022.340561 SN - 0003-2670 VL - 1238 SP - 1 EP - 12 PB - Elsevier B.V. AN - OPUS4-56366 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Even, Morgane A1 - Juritsch, Elevtheria A1 - Richter, Matthias T1 - On the use of Carbograph 5TD as an adsorbent for sampling VVOCs: validation of an analytical method N2 - A standardised method for the analysis of very volatile organic compounds (VVOCs) in indoor air is still missing. This study evaluates the use of Carbograph 5TD as an adsorbent for 60 compounds (47 VVOCs + 13 VOCs) by comparing their recoveries with different spiking modes. The influence of the spiking of the tubes in dry nitrogen, humidified air or along the whole flushing duration mimicking real sampling was investigated. 49 substances (36 VVOCs from C1 to C6) had recoveries over 70% on the adsorbent in humidified air and were validated. The linearity of the calibration curves was verified for every spiking mode and the limits of detection (LOD) and quantification (LOQ) were determined. The LOQs were lower than the existing indoor air guideline values. The robustness of the method was considered by studying the influence of the sampling volume, the sampling flow rate, the humidity level and the storage of the tubes. In general, the most volatile or polar substances were the less robust ones. The combined measurement uncertainty was calculated and lies below 35% for a vast majority of the substances. An example of an emission chamber test using polyurethane foam is shown: Carbograph 5TD performs much better than Tenax® TA for VVOCs and emissions from n-butane were quantified with combined measurement uncertainty. KW - VVOC KW - Gas chromatography KW - Thermal desorption KW - Air sampling PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-581113 DO - https://doi.org/10.1039/D3AY00677H VL - 15 IS - 31 SP - 3810 EP - 3821 AN - OPUS4-58111 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Even, Morgane A1 - Juritsch, Elevtheria A1 - Richter, Matthias T1 - Weiterentwicklung und Validierung eines leistungsfähigen Verfahrens zur Bestimmung von leicht flüchtigen organischen Verbindungen (VVOC) bei Emissionsmessungen aus Bauprodukten und in der Innenraumluft N2 - Ziel dieses Forschungsprojekts war es, eine leistungsfähige Gesamtstrategie zur Bestimmung von leicht flüchtigen organischen Verbindungen (VVOC) auf Grundlage der Prüfmethode aus ISO 16000-6 in Verbindung mit EN 16516 vorzuschlagen. Es soll bei Emissionsmessungen sowohl aus Bauprodukten als auch in der Innenraumluft angewendet werden können und ein großes Emissionsspektrum abdecken, um möglichst wenige Einzelprüfungen durchführen zu müssen. Als Gegenstand für sämtliche Untersuchungen diente ein 60-komponentiger Testgasstandard. Mit dessen Hilfe erfolgten dann schließlich systematische Eignungsuntersuchungen für Chromatographiesäulen und Adsorbenzien für die Probenahme, die Untersuchung der Einflüsse von Luftfeuchtigkeit, Probenahmevolumen und -volumenstrom auf die Analyse, Untersuchungen zum Umgang mit Feuchtigkeit in der Probenluft, die Bestimmung von Wiederfindungsraten, Nachweis- und Bestimmungsgrenzen sowie der Robustheit des Verfahrens und der Messunsicherheit im Rahmen der Verfahrensvalidierung. Die entwickelte Messmethode wurde im Rahmen einer Emissionsmessung an einem Polyurethanschaum erprobt. Im Ergebnis entstand eine robuste Methode, die es erlaubt, komplexe VVOC-Gemische mit sehr guter Auflösung und niedrigen Nachweis- und Bestimmungsgrenzen zu analysieren. Ferner wurde ein Vorschlag zur Erweiterung des zu erfassenden Flüchtigkeitsspektrums bis C22 erarbeitet, der zwar nicht vollständig validiert werden konnte, jedoch die prinzipielle Machbarkeit zeigt. KW - VVOC KW - Thermodesorptions-GC/MS KW - Bauproduktemission KW - Innenraumluftqualität PY - 2024 UR - https://www.umweltbundesamt.de/publikationen/weiterentwicklung-validierung-eines SN - 1862-4804 VL - 131/2024 SP - 1 EP - 154 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-61147 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -