TY - CONF A1 - Climent Terol, Estela A1 - Costa, Elena A1 - Weller, Michael G. A1 - Rurack, Knut T1 - Antibody-gated dye delivery systems for Type-I pyrethroids detection N2 - Type-I pyrethroids are frequently used for disinfection purposes on airplanes from and to tropical areas. The WHO (Word Health Organization) defines “disinfection” as the procedure whereby health measures are taken to control or kill the insect vectors of human diseases including dengue, yellow fever and malaria.1 Due to this, a new effective and rapid method for pyrethroids analysis directly in the plane is needed. To detect type-I pyrethroids, gated materials are constructed for the purpose of finely tuning the movement of a cargo from voids of a mesoporous inorganic support to a solution, in response to a predefined stimulus.2 Antibodies are bound to specific functional groups grafted on the support’s surface with the two-fold aim of closing the mesopores and working as biological receptors for the target compounds.2 A specific opening mechanism, activated selectively in presence of pyrethroids as analytes, is able to control the release of an indicator dye previously loaded inside the inorganic support. As only few molecules of pyrethroids are necessary to open a pore and release a large amount of dyes, the system shows an intrinsic signal amplification quantified as a fluorescence emission intensity.3 Different mesoporous silica supports (from nano- and microparticles to platelets and short fibers) were synthetized, characterized and functionalized following different capping strategies. In this contribution, we will compare the temporal response behaviour of the optimized gated materials to verify if the respective delivery systems are properly closed and how fast they can be opened in presence of the analytes. Our results indicate that the trends of the kinetics observed in solution show a better control of the closing/opening mechanism when the epitope region of the antibody (around 10 nm) properly fits the pore size of the carriers. Because the incorporation of an antibody-gated dye-delivery system with a conventional test-strip-based lateral-flow assay allows for the detection of analytes down to the ppb level in an easy-to-operate manner and an overall assay time of 2–5 min, which is fast for a biochemical test,3 we carried out first model studies for a lateral flow test assay on membranes, using a smartphone setup for read-out. T2 - XV EUROPT(R)ODE 2021 CY - Online meeting DA - 28.11.2021 KW - Antibody-gated materials KW - Lateral flow assay KW - Pyrethroids detection PY - 2021 AN - OPUS4-53862 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Climent Terol, Estela A1 - Biyikal, Mustafa A1 - Gröninger, Delia A1 - Weller, Michael G. A1 - Martínez-Máñez, Ramón A1 - Rurack, Knut T1 - Fluorescence-based multiplexed detection on single test strips with antibody-gated mesoporous materials N2 - Rapid testing methods for the use directly at a point-of-need are expected to unfold their true potential especially when offering adequate capabilities for the simultaneous measurement of multiple analytes of interest. However, the implementation of multiplexing features while retaining simplicity, performance and portability is one of the prominent challenges in the field. Keeping in mind these challenges, we decided to combine the use of stimuli-responsive materials for small-molecule sensing relying on chemical signal amplification and their incorporation on paper strips for lateral-flow assays in a straightforward manner. Considering the modularity, high sensitivity and selectivity of antibody-gated indicator delivery systems, a multiplexed assay for three small-molecule explosives TATP, TNT and PETN was developed, allowing to detect the analytes simultaneously with a single test strip at lower ppb concentrations in liquid phase in <5 min, using a fluorescence reader or a smartphone for readout. Because of the versatility of the hybrid material and the modularity of the assay architecture, it is obvious that this generic approach should be easily transferable to food or environmental analysis, point-of-care diagnostics and other areas of application in which the rapid screening for multiple parameters from liquid samples without clean-up in a dedicated laboratory is in demand. T2 - 2021 On-line Symposium on Bioluminiscence, Chemiluminiscence and luminescence spectrometry ISLS-ISBC CY - Online meeting DA - 24.06.2021 KW - Multiplexing KW - Hybrid materials KW - Signal amplification KW - Test Strip analysis KW - Explosives PY - 2021 AN - OPUS4-52889 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Climent Terol, Estela A1 - Gröninger, Delia A1 - Hecht, Mandy A1 - Keil, Karin A1 - Rurack, Knut T1 - Sensitive, selective, and rapid analysis based on antibody-gated dye-delivery systems for the detection of explosives T2 - NANOSMAT Conference CY - Dublin, Ireland DA - 2014-09-08 PY - 2014 AN - OPUS4-31353 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Climent Terol, Estela T1 - Design and synthesis of lateral flow tests containing antibody-gated materials N2 - Methods for the rapid and sensitive detection of target analytes are gaining importance in medical diagnostics and environmental monitoring, in the security, occupational health and safety as well as food sectors. Among all the methods employed for rapid tests, lateral flow assays (LFAs) are the most commonly used. However, some drawbacks are that most of these tests either indicate the analyte only indirectly, and in other cases the sensitivity is not high enough. Keeping in mind these limitations, the use of stimuli-responsive materials for small-molecule sensing relying on chemical signal amplification and utilizing specific interactions between biomolecules such as antibodies and the corresponding analytes are particularly attractive. Such materials can also be incorporated on paper strips for lateral-flow assays in a straightforward manner. These sensing materials comprise mesoporous silica nanoparticles loaded with indicator molecules and containing certain hapten derivative molecules covalently grafted at the surface, which bind to the respective antibody and inhibit the release of a dye as reporter (Scheme 1). In presence of the designated analyte, a displacement of the antibody from the material is observed, allowing the release of dye. Because a large number of indicator molecules can be released when a single analyte molecule binds to an antibody cap, a strong signal amplification is observed. Considering the modularity, high sensitivity and selectivity of these antibody-gated indicator delivery systems, the presentation discusses general aspects of system design as well as analytical performance and highlights the integration into a lateral-flow assay, showing as an example the determination of the explosives TATP, TNT and PETN with a fluorescence readout, in single-substance and multiplexing modes. T2 - International Webinar on Biosensors and Bioelectronics CY - Online meeting DA - 20.07.2020 KW - Multiplexing detection KW - Rapid testing methods KW - Gated hybrid materials KW - Lateral flow tests KW - Explosives detection PY - 2020 UR - https://europeanmeetings.net/conferences/biosensor-bioelectronics AN - OPUS4-51038 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Climent Terol, Estela A1 - Rurack, Knut T1 - Integration of novel specific gated hybrid materials into versatile platforms for advanced sensing applications T2 - Network Meeting of the Alexander von Humboldt Fundation CY - Bremen DA - 2015-04-15 PY - 2015 AN - OPUS4-33541 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Climent Terol, Estela A1 - Costa, Elena A1 - Gawlitza, Kornelia A1 - Wan, Wei A1 - Weller, Michael G. A1 - Rurack, Knut T1 - Antibody-gated indicator releasing mesoporous materials: a potential biosensor platform to be used in the development of rapid tests N2 - The urgent necessity to carry out reliable and relevant analytical measurements directly at a point-of-need is one of the current drivers for the development of miniaturised analytical systems, quick tests and wearables. Despite their simplicity, this type of tests must guarantee analytical relevance and reliability like laboratory-based analysis, e.g., in terms of sensitivity, selectivity, immunity against false positives and false negatives as well as robustness and repeatability. Keeping in mind the high sensitivity offered by gated indicator-releasing micro- and nanoparticles due to their inherent features of signal amplification, we performed several optimisations to develop a potential biosensor platform for use in rapid tests. Conceptually, these gated materials are closely related to drug delivery systems, consisting of high porous materials usually closed with macromolecular “caps” and loaded with indicator molecules that are released in presence of a target analyte. However, the key difference between the two types of functional materials is that many drug delivery systems should deliver their cargo over a longer period, often many hours, whereas the gated materials prepared for sensing should show fast release kinetics, on the order of <5 min. With the aim to optimise and adapt gated materials for sensing purposes, we prepared in this work several antibody-gated materials for small-molecule sensing. The materials consisted of porous silica particles containing indicator molecules in the pores and certain hapten molecules grafted to the particle surface close to the pore openings. The pores were then capped with antibodies binding to these haptens, thus inhibiting the escape of the indicators from inside of the pores. In presence of the corresponding analyte, the antibody is displaced from the surface of the material, allowing the escape of the indicators. This allows the detection of the analyte indirectly through an inherent signal amplification. In this work, the insecticide permethrin, a type-I pyrethroid, was selected as target model, because type-I pyrethroids play an important role in airplane disinfection. A first in-depth study of the various chemical tuning options of such antibody gated systems was performed. Different mesoporous silica supports, different functionalisation routes and different loading sequences were assessed. The materials’ performances were evaluated by studying their temporal response behaviour and detection sensitivity, including the tightness of pore closure (through the amount of blank release in absence of analyte) and the release kinetics. Our results indicate that the better the paratope-accommodating Fab region of the antibody “cap” fits into the host material’s pore openings, the better the closing/opening mechanism can be controlled. Because such materials can be used in various different formats from suspension assays[1] via microfluidic chips[2] to test strip-based lateral flow assays,[3] such materials present a powerful analytical particle platform for the sensitive analytics and diagnostics outside of a laboratory, realising sensitivities down to the µg kg–1 range in less analysis times of less than 5 min as we have recently demonstrated.[4] T2 - Biosensors for Pandemics CY - Online conference DA - 06.05.2020 KW - Hybrid materials KW - Pyrethroids KW - Signal amplification PY - 2020 UR - http://www.confstreaming.com/Biosensors2020/ AN - OPUS4-50744 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Climent Terol, Estela A1 - Wan, Wei A1 - Weller, Michael G. A1 - Rurack, Knut T1 - Novel specific bio-gated hybrid materials and their integration into versatile platforms for advanced sensing applications N2 - Methods for the rapid and sensitive detection of target analytes are gaining importance in medical diagnostics and environmental monitoring, in the security, occupational health and safety as well as food sectors. Among all of the methods employed for rapid tests, lateral flow assays (LFAs) are the most commonly used, and hundreds of test kits based on this technique are available on the market. A major drawback is that most of these capture agents either indicate the analyte only indirectly, and in most cases a second binding agent able to bind directly or indirectly to the analytes is necessary (e.g., a secondary labeled antibody). Furthermore, in certain cases in which the (ultra)trace detection of an analyte is required, the traditional approach of a certain number of probe molecules being conjugated to a particular support is not sufficient. Therefore, novel concepts implementing steps of effective signal amplification are urgently required. Keeping in mind these limitations, we thought that the sensitivity of these systems should be improvable through employment of gated reporter molecule-releasing hybrid nanoparticle materials on novel lateral flow devices. On one hand, the gated sensor material can produce a massive signal amplification, by releasing many reporter molecules only after chemical recognition of a few analyte molecules has taken place in an independent and separate step at the pore openings. On the other hand, the employment of tailored capture materials for the selective interaction with the released reporter molecules in a second arbitrary zone on the strip allows to concentrate or focus the latter for more efficient detection or to create selective multi-spot detection zones, which renders the simultaneous detection of several reporter molecules at the same time in multiplexed detection of various analytes possible. For that purpose, we have prepared several stimuli-responsive materials for small-molecule sensing based on specific interactions between biomolecules such as antibodies with the corresponding analytes for the detection of certain explosives. In order to prepare these bio-capped materials, we have selected silica mesoporous nanoparticles (MSNs) as inorganic support due to their unique properties such as defined void structure, high inner surface area and flexible functionalization chemistry. These MSNs are loaded with a brightly fluorescent indicator dye, and the external surface is subsequently functionalized with suitable molecules able to interact with antibodies, efficiently inhibiting dye release. The opening protocol and delivery of the entrapped dye is reminiscent of a displacement reaction involving the presence of the target analyte, producing a displacement of the biomolecule and allowing the detection of the target analyte. The presentation discusses general aspects of system design as well as analytical performance and highlights the integration into a lateral-flow assay, showing as an example the determination of the explosives TATP, TNT and PETN with fluorescence readout, in single-substance and multiplexing modes. T2 - EBS 2019 CY - Florence, Italy DA - 18.02.2019 KW - Bio-gated hybrid materials KW - Signal amplification KW - Explosives determination KW - Fluorescence KW - Rapid test KW - Dip-stick assay PY - 2019 AN - OPUS4-47920 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bell, Jérémy A1 - Climent, Estela A1 - Gotor, Raúl A1 - Tobias, Charlie A1 - Martin-Sanchez, Pedro M. A1 - Rurack, Knut T1 - Dipstick coated with polystyrene-silica core-shell particles for the detection of microbiological fuel contamination N2 - Microbial contamination of fuels by fungi or bacteria poses risks such as corrosion and fuel system fouling, which can lead to critical problems in refineries and distribution systems and has a significant economic impact at every stage of the process. Many factors have been cited as being responsible for microbial growth, like the presence of water in the storage tanks. In fact, only 1 % water in a storage system is sufficient for the growth of microorganisms like bacteria or yeasts, as well as for the development of fungal biomass at the oil/water interface. This work presents a rapid test for the accurate determination of genomic DNA from aqueous fuel extracts. The detection is based on the use of polystyrene-mesoporous silica core-shell particles onto which modified fluorescent molecular beacons are covalently grafted. These beacons contain in the hairpin loop a target sequence highly conserved in all bacteria, corresponding to a fragment of the 16S ribosomal RNA subunit. The designed single-stranded molecular beacon contained fluorescein as an internal indicator and a quencher in its proximity when not hybridized. Upon hybridization in presence of the target sequence, the indicator and the quencher are spatially separated, resulting in fluorescence enhancement. To perform the assay the developed particles were deposited on different glass fibre strips to obtain a portable and sensitive rapid test. The assays showed that the presence of genomic DNA extracts from bacteria down to 50–70 μg L–1 induced a fluorescence response. The optical read-out was adapted for on-site monitoring by fitting a 3D-printed case to a conventional smartphone, taking advantages of the sensitivity of the CMOS detector. Such embedded assembly enabled the detection of genomic DNA in aqueous extracts down to the mg L–1 range and represents an interesting step toward on-site monitoring of fuel contamination. T2 - IMA 2023 CY - Chania, Greece DA - 18.09.2023 KW - Teststreifen KW - Test strip KW - Microbial KW - Mikrobiell KW - Smartphone KW - Particles KW - Partikeln PY - 2023 AN - OPUS4-58526 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Climent, Estela A1 - Rurack, Knut A1 - Martinez-Manez, R. T1 - Strip-Based Rapid Tests Containing Gated Mesoporous Materials: A Perfect Combination for Sensitivity Improvement N2 - Rapid tests and assays to be used outside of a laboratory for non-trained personal and also at a point of need are becoming increasingly important in areas such as health, food, security, or the environment. Specially on that regard, paper-based sensors are emerging as a new class of devices because they fulfil the requisites of the "World Health Organization" to be ASSURED: affordable, sensitive, specific, user-friendly, rapid and robust, equipment free and deliverable to end-users. The physical, chemical and mechanical properties of cellulose or glass fiber paper in combination with the facility of preparation are making these materials of great interest while looking for cost-efficient and green alternatives for device production technologies. To improve the sensitivity of these systems, a particularly promising approach is the employment of gated indicator delivery systems using preorganized nanoscopic solid structures incorporated on paper strips to produce an exponential amplification of the detectable signal. Having in mind these concepts, several examples of (bio)gated materials incorporated into sensing membranes will be presented for the detection of small organic molecules, having fluorescence or electrochemiluminescence signal as output signal. Compared with fluorescence, it has been demonstrated that the non-optical excitation has significantly reduced the background signal, and with the help of a portable potentiostat in combination with a home-made 3D-printed case fitted onto a smartphone, the sensitivity of the sensing system has been improved tremendously, from the lower ppb range (fluorescence) to the lower ppt range. With this study, the applicability of ECL detection on paper strips in combination with gated indicator-releasing materials has been demonstrated for the first time, presenting a novel synergistic match. Considering the modularity of the system developed, the platform technology potential is obvious, promising expansion of the general concept to many other analytes, applications and scenarios. T2 - XVI International Workshop on Sensors and Molecular Recognition CY - Valencia, Spain DA - 06.07.2023 KW - Schnelltest KW - Vor-Ort-Analytik KW - Lateral Flow Assays KW - Indikatorfreisetzung KW - Fluoreszenz PY - 2023 AN - OPUS4-57966 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -