TY - JOUR A1 - Sadowski, A. A1 - Seidel, M. A1 - Al-Lawati, H. A1 - Azizi, E. A1 - Balscheit, Hagen A1 - Böhm, M. A1 - Chen, Lei A1 - van Dijk, I. A1 - Doerich-Stavridis, C. A1 - Kunle Fajuyitan, O. A1 - Filippidis, A. A1 - Winther Fischer, A. A1 - Fischer, C. A1 - Gerasimidis, S. A1 - Karampour, H. A1 - Kathirkamanathan, L. A1 - Subramanian, S. A1 - Topkaya, Cem A1 - Wagner, H. N. R. A1 - Wang, J. A1 - Wang, J. A1 - Kumar Yadav, K. A1 - Yun, X. A1 - Zhang, P. T1 - 8-MW wind turbine tower computational shell buckling benchmark - Part 1: An international ‘round-robin’ exercise N2 - An assessment of the elastic-plastic buckling limit state for multi-strake wind turbine support towers poses a particular challenge for the modern finite element analyst, who must competently navigate numerous modelling choices related to the tug-of-war between meshing and computational cost, the use of solvers that are robust to highly nonlinear behaviour, the potential for multiple near-simultaneously critical failure locations, the complex issue of imperfection sensitivity and finally the interpretation of the data into a safe and economic design. This paper reports on an international ‘round-robin’ exercise conducted in 2022 aiming to take stock of the computational shell buckling expertise around the world which attracted 29 submissions. Participants were asked to perform analyses of increasing complexity on a standardised benchmark of an 8-MW multi-strake steel wind turbine support tower segment, from a linear elastic stress analysis to a linear bifurcation analysis to a geometrically and materially nonlinear buckling analysis with imperfections. The results are a showcase of the significant shell buckling expertise now available in both industry and academia. This paper is the first of a pair. The second paper presents a detailed reference solution to the benchmark, including an illustration of the Eurocode-compliant calibration of two important imperfection forms. KW - Wind turbine tower KW - Computational KW - Shell buckling KW - Benchmark PY - 2023 DO - https://doi.org/10.1016/j.engfailanal.2023.107124 SN - 1350-6307 VL - 148 SP - 1 EP - 23 PB - Elsevier Science CY - Oxford AN - OPUS4-57019 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Szafarska, E. A1 - Mohr, F. A1 - Fischer, E. A1 - Erhard, Anton T1 - Phased array: well qualified for core shroud inspection PY - 1997 SN - 0029-5507 VL - 1/9 SP - 24 EP - 25 PB - Business Press Internat. CY - Sutton AN - OPUS4-18770 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Becker, S. A1 - Beckmann, Jörg A1 - Braun, M.-T. A1 - Cojocari, O. A1 - Feige, V. A1 - Fischer, B. A1 - Friederich, F. A1 - Globisch, B. A1 - Hechtfischer, G. A1 - Hens, K. A1 - Hübers, H.-W. A1 - Jelonnek, J. A1 - Jonuscheit, J. A1 - Keil, A. A1 - Kleine-Ostmann, T. A1 - Marquardt, E. A1 - Mayr, M. A1 - Nickel, H.-U. A1 - Nüßler, D. A1 - Peichl, M. A1 - Peters, O. A1 - Schür, J. A1 - Sprenger, T. A1 - Steiger, A. A1 - van Frank, S. A1 - Vieweg, N. A1 - Wilk, R. ED - Jonuscheit, J. ED - Marquardt, E. T1 - Terahertzsysteme und Anwendungsfelder N2 - Der Frequenzbereich der Terahertzwellen liegt im elektromagnetischen Spektrum zwischen den Mikrowellen und dem infraroten Licht – also etwa im Bereich von 0,1 bis 10 Terahertz (THz). Der VDI-Statusreport „Terahertzsysteme und Anwendungen“ stellt die unterschiedlichen Konzepte für Terahertzsysteme vor und zeigt Anwendungsbeispiele, bei denen die Terahertztechnik erfolgreich eingesetzt wird. Umfangreiche Literaturangaben ermöglichen eine intensivere Beschäftigung mit allen Themen des VDI-Statusreports. KW - Terahertzsysteme PY - 2020 UR - https://www.vdi.de/ueber-uns/presse/publikationen/details/terahertzsysteme-und-anwendungsfelder SP - 1 EP - 44 PB - Verein Deutscher Ingenieure (VDI) CY - Düsseldorf AN - OPUS4-50556 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schoknecht, Ute A1 - Drescher, P. A1 - Fischer, M. A1 - Fürhapper, C. A1 - Gunschera, J. A1 - Hill, R. A1 - Melcher, E. A1 - Wegner, R. A1 - Wilken, U. A1 - Wittenzellner, J. T1 - Suitability of analytical methods to determine tebuconazole, propiconazole and permethrin in aged wood samples N2 - The suitability of common analytical methods for the determination of active substances from wood preservatives in aged wood samples was investigated during an interlaboratory study. Permethrin, propiconazole and tebuconazole were quantified in 1.5 and 8 year-old wood samples by gas chromatography and liquid chromatography. Generally, the applied Methods yielded reliable results for these samples. However, wood components can coelute with propiconazole and tebuconazole during liquid chromatography. Optimization of separation might be required if UV detection is applied. KW - Wood samples KW - Biocides KW - Analytical methods PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-503959 DO - https://doi.org/10.1007/s00107-020-01496-y VL - 78 IS - 2 SP - 271 EP - 279 PB - Springer CY - Heidelberg AN - OPUS4-50395 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gehrenkemper, Lennart A1 - Simon, Fabian A1 - Roesch, Philipp A1 - Fischer, E. A1 - von der Au, Marcus A1 - Pfeifer, Jens A1 - Cossmer, Antje A1 - Wittwer, Philipp A1 - Vogel, Christian A1 - Simon, Franz-Georg A1 - Meermann, Björn T1 - Determination of organically bound fluorine sum parameters in river water samples - Comparison of combustion ion chromatography (CIC) and high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) N2 - In this study, we compare combustion ion chromatography (CIC) and high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) with respect to their applicability for determining organically Bound fluorine sum parameters. Extractable (EOF) and adsorbable (AOF) organically bound fluorine as well as total fluorine (TF) were measured in samples fromriver Spree in Berlin, Germany, to reveal the advantages and disadvantages of the two techniques used as well as the two established fluorine sum Parameters AOF and EOF. TF concentrations determined via HR-CS-GFMAS and CIC were comparable between 148 and 270 μg/L. On average, AOF concentrations were higher than EOF concentrations, with AOF making up 0.14–0.81% of TF (determined using CIC) and EOF 0.04–0.28% of TF (determined using HR-CSGFMAS). The results obtained by the two independent methods were in good agreement. It turned out that HR-CS-GFMAS is a more sensitive and precise method for fluorine analysis compared to CIC. EOF and AOF are comparable tools in Risk evaluation for the emerging pollutants per- and polyfluorinated alkyl substances; however, EOF is much faster to conduct. KW - High resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) KW - Combustion ion chromatography (CIC) KW - Per- and polyfluorinated alkyl substances (PFASs) KW - Adsorbable organically bound fluorine (AOF) KW - Extractable organically bound fluorine (EOF) KW - Surface waters PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-515351 DO - https://doi.org/10.1007/s00216-020-03010-y SN - 1618-2650 VL - 413 IS - 28 SP - 103 EP - 115 PB - Springer CY - Berlin AN - OPUS4-51535 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Weber, A. A1 - von Randow, M. A1 - Voigt, A.-L. A1 - von der Au, Marcus A1 - Fischer, E. A1 - Meermann, Björn A1 - Wagner, M. T1 - Ingestion and toxicity of microplastics in the freshwater gastropodLymnaea stagnalis: No microplastic-induced effects alone or incombination with copper N2 - The interaction of microplastics with freshwater biota and their interaction with other stressors is still not very well understood. Therefore, we investigated the ingestion, excretion and toxicity of microplastics in the freshwater gastropod Lymnaea stagnalis. MP ingestion was analyzed as tissues levels in L. stagnalis after 6–96 h of exposure to 5–90 μm spherical polystyrene (PS) microplastics. To understand the excretion, tissue levels were determined after 24 h of exposure followed by a 12 h–7 d depuration period. To assess the toxicity, snails were exposed for 28 d to irregular PS microplastics (<63 μm, 6.4–100,000 particles mL−1), both alone and in combination with copper as additional stressor. To compare the toxicity of natural and synthetic particles, we also included diatomite particles. Microplastics ingestion and excretion significantly depended on the particle size and the exposure/depuration duration. An exposure to irregular PS had no effect on survival, reproduction, energy reserves and oxidative stress. However, we observed slight effects on immune cell phagocytosis. Exposure to microplastics did not exacerbate the reproductive toxicity of copper. In addition, there was no pronounced difference between the effects of microplastics and diatomite. The tolerance towards microplastics may originate from an adaptation of L. stagnalis to particle-rich environments or a general stress resilience. In conclusion, despite high uptake rates, PS fragments do not appear to be a relevant stressor for stress tolerant freshwater gastropods considering current environmental levels of microplastics. KW - Lymnaea stagnalis KW - Microplastic-induced effects KW - Mixture toxicity PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-513551 DO - https://doi.org/10.1016/j.chemosphere.2020.128040 VL - 263 SP - 128040 PB - Elsevier Ltd. AN - OPUS4-51355 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Gehrenkemper, Lennart A1 - Simon, Fabian A1 - Roesch, Philipp A1 - Fischer, E. A1 - von der Au, Marcus A1 - Pfeifer, Jens A1 - Cossmer, Antje A1 - Wittwer, Philipp A1 - Vogel, Christian A1 - Simon, Franz-Georg A1 - Meermann, Björn T1 - Correction to: Determination of organically bound fluorine sum parameters in river water samples - Comparison of combustion ion chromatography (CIC) and high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS) N2 - The article “Determination of organically bound fluorine sum parameters in river water samples - Comparison of combustion ion chromatography (CIC) and high resolution-continuum source-graphite furnace molecular absorption spectrometry (HR-CS-GFMAS)” was originally published Online First without Open Access. After publication in volume 413, issue 1, page 103–115 of the journal “Analytical and bioanalytical chemistry”, the authors decided to opt for Open Choice and to make the article an Open Access publication. Therefore, the copyright of the article has been changed to © The Author(s) 2021 and the article is forthwith distributed under the terms of the Creative Commons Attribution 4.0 International License. PY - 2020 DO - https://doi.org/10.1007/s00216-021-03675-z SN - 1618-2650 SP - 1 PB - Springer CY - Berlin AN - OPUS4-53453 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Erhard, Anton A1 - Schenk, Gottfried A1 - Gohlke, Dirk A1 - Engl, G. A1 - Fischer, E T1 - The SAPHIR and MINI-SAPHIR System - Versatile Tools for Advanced Solutions for the PWR Primary Circuit Inspection T2 - First International Conference on NDE in relation to Structural Integrity for Nuclear and Pressurised Components Amsterdam CY - Amsterdam, Netherlands DA - 1998-10-20 PY - 1998 AN - OPUS4-18875 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Erhard, Anton A1 - Wüstenberg, Hermann A1 - Fischer, E. A1 - Rathgeb, Werner A1 - Tagliamonte, M. T1 - Increasing the Reliability and Redundancy for Reactor Pressure Vessel Weld Inspection by Advanced UT-Techniques T2 - EPRI, Vessel and Internal Inspection Conference CY - San Antonio, TX, USA DA - 1994-07-11 PY - 1994 AN - OPUS4-18853 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Erhard, Anton A1 - Wüstenberg, Hermann A1 - Fischer, E. A1 - Rathgeb, Werner T1 - Ultrasonic Hybrid-Phased-Array-Probe for Weld Inspection at the BWR Pressure Vessel T2 - 6th ECNDT-European Conference on Non Destructive Testing CY - Nice, France DA - 1994-10-24 PY - 1994 AN - OPUS4-18855 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Erhard, Anton A1 - Thomas, Hans-Martin A1 - Fischer, E. T1 - Prüfung der Plattierung von Behältern mit gepulstem Wirbelstrom und Ultraschall T2 - 1. Französisch-Deutsches Seminar "Anwendung von ZfP-Mehrfachprüftechnik zur Verbesserung von Auffindbarkeit und Deutung" CY - Metz, France DA - 1995-10-12 PY - 1995 AN - OPUS4-18858 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Liebner, Christian A1 - Hieronymus, Hartmut A1 - Fischer, J. A1 - Klemm, E. T1 - Untersuchungen zur Explosionsausbreitung in mikrostrukturierten Reaktoren T2 - 12. Kolloquium zu Fragen der chemischen und physikalischen Sicherheitstechnik CY - Berlin, Deutschland DA - 2010-06-15 KW - Deflagration KW - Detonation KW - Mikroreaktionstechnik KW - Mikroreaktor KW - Sicherheitstechnik PY - 2010 SN - 978-3-9813550-1-7 SN - 0938-5533 SP - 7 EP - 10 PB - BAM Bundesanstalt für Materialforschung und -prüfung CY - Berlin AN - OPUS4-21495 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -