TY - JOUR A1 - Fürst, Richard A1 - Häßler, Dustin A1 - Hothan, Sascha T1 - Influence of the profile type and bar orientation on the performance of intumescent coatings applied to steel tension bars JF - Fire safety journal N2 - Intumescent coatings are commonly used in civil engineering to improve the fire resistance of steel constructions. Especially in the case of tension bars, where mostly circular or rectangular solid sections are used, intumescent coatings offer an efficient measure to improve the fire resistance taking advantage of profile-following application and low coating thickness requirements. Thus, the architectural appearance of slender profiles can be preserved. The paper describes real-scale mechanically loaded and unloaded fire tests of circular and rectangular solid steel tension bars with intumescent coating. The aim of these tests is to investigate the influence of the different profile types as well as different bar orientations on the performance of intumescent coatings. The results are used to specify a normative test and assessment procedure to be implemented in a new European standard for determining the contribution of intumescent coatings to the fire resistance of circular or rectangular bars used as tension members. KW - Fire test KW - Intumescent coating KW - Steel tension member KW - Fire resistance PY - 2022 DO - https://doi.org/10.1016/j.firesaf.2022.103678 SN - 0379-7112 VL - 134 SP - 1 EP - 14 PB - Elsevier CY - Amsterdam AN - OPUS4-56172 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fürst, Richard A1 - Häßler, Dustin A1 - Peter, A. A1 - Rohleder, R. A1 - Hothan, Sascha T1 - European test standard intumescent coatings applied to steel tension bars with solid section T2 - 8th Symposium Structural Fire Engineering N2 - Intumescent coatings are used in civil engineering to improve the fire resistance of steel constructions. Due to the thin coating thickness and the profile-following application, the architectural appearance of the steel structure can be preserved. EN 13381-8 provides regulations to determine the contribution to the fire resistance of intumescent coatings applied to steel beams and columns. The scope of this standard excludes tension members and steel members with solid sections. For products that have already been successfully tested and assessed on beams and columns, EN 13381-10 offers the possibility based on unloaded fire tests to extend the scope of application of intumescent coatings to tension bars with solid sections. This approach contradicts the national safety level in Germany, where mechanically loaded testing is mandatory. Therefore, a new part of the test standard series EN 13381 is currently developed to enable the application of intumescent coatings on steel tension bars with solid section based on mechanically loaded fire tests. BAM has already carried out numerous fire tests on loaded steel tension members with intumescent coatings. Currently, in the BAM research project FIRESTEMIC, the influence of the steel bar orientation and the profile type on the thermal performance of intumescent coatings are investigated. Both questions concerning the thermal protection ability of intumescent coatings were analysed based on three different test sets, which were carried out in the tension furnace (Fig. 1a). The fire exposure corresponds to the standard temperature-time curve according to EN 1363-1. This paper summarises the main findings from the fire tests conducted in the FIRESTEMIC project. The results serve as an experimental background for the proposal of the new standard. Regarding the bar orientation, a new test setup was developed and proposed for the new standard. The two tested commercial water-based intumescent coatings with applied dry film thickness from 1.5 mm to 2.5 mm showed only a slight dependence on the bar orientation. In terms of the steel profile type, circular and rectangular solid sections with identical section factor and applied dry film thickness were tested. It was observed that the circular solid bars with diameter 30 mm heat up faster compared to the solid rectangular bars with dimension 30×30 mm (Fig. 1b). Also at larger steel bars, i.e. diameter 40 mm and dimension 40×40 mm, the same trend occurred. Thus, it is recommended for the new test standard to allow a transfer of the test results from circular to rectangular solid sections. In addition, the paper will describe and explain the test and assessment procedure proposed for the newly developed standard. T2 - 8th Symposium Structural Fire Engineering CY - Brunswick, Germany DA - 13.09.2022 KW - Fire test KW - Steel KW - Tension member KW - Intumescent coating KW - Test standard PY - 2022 SP - 1 EP - 14 PB - TU Braunschweig CY - Braunschweig AN - OPUS4-55703 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Hothan, Sascha A1 - Häßler, Dustin A1 - Fürst, Richard A1 - Peter, A. A1 - Wöhr, M. A1 - Rohleder, R. T1 - Entwicklung einer europäischen Prüfnorm zur Bestimmung des Feuerwiderstands von Stahlzuggliedern mit reaktiver Brandschutzbeschichtung anhand belasteter Brandprüfungen T1 - Development of a European test standard for the determination of the fire resistance of steel tension members with intumescent fire protection coating based on loaded fire tests N2 - Ziel des Forschungsvorhabens ist es, ein standardisiertes Prüf- und Bewertungsverfahren zur Bestimmung des Beitrags reaktiver Brandschutzsysteme (RBS) zum Feuerwiderstand von Stahlzuggliedern zu erarbeiten und dieses in ein Entwurfsdokument für eine europäische Prüfnorm zu überführen. Hierzu wurden einerseits bereits vorhandene Erfahrungen und Erkenntnisse genutzt und andererseits mittels Brandversuchen neue Prüfdaten zur Beantwortung bisher offengebliebener Aspekte zum Einfluss der Bauteilorientierung und Profilart erzeugt und ausgewertet. Dadurch wird die prüftechnische Grundlage für eine sichere, zulassungsbasierte Anwendung von reaktiven Brandschutzsystemen auf zugbeanspruchten Stahlbauteilen gelegt und ein einheitliches Sicherheitsniveau etabliert. Der im Rahmen des Forschungsprojektes entwickelte Normentwurf wurde mit den Fachexperten der zuständigen nationalen und europäischen Normungsgremien diskutiert und abgestimmt. Das erarbeitete Prüf- und Auswertungsverfahren basiert auf der Durchführung von Brandversuchen an mechanisch belasteten Stahlzuggliedern mit RBS. Ergänzend sind unbelastete Brandversuche zur Beurteilung des Einflusses der Bauteilorientierung sowie der Eignung bei Schwelbrandbeanspruchung möglich. Die im Projekt durchgeführten experimentellen Untersuchungen liefern die Grundlage für den im Normenentwurf vorgeschlagenen Prüfaufbau der mechanisch belasteten und unbelasteten Brandversuche. Ferner konnte durch die Untersuchungen gezeigt werden, dass sich unter bestimmten Voraussetzungen die Prüfergebnisse von Stahlzuggliedern mit Kreisvollprofil ohne zusätzliche Brandversuche auf entsprechende Zugglieder mit Rechteckvollprofil übertragen lassen. Darüber hinaus konnte belegt werden, dass die Leistungsfähigkeit eines RBS aufgrund unterschiedlicher Bauteilorientierungen abnehmen kann und daher zwingend beim Anwendungsbereich des RBS zu berücksichtigen ist. Hierzu wird ein Temperaturdifferenz-kriterium vorgeschlagen, bei dessen Einhaltung die Wirksamkeit des RBS bei von der horizontalen Referenzorientierung abweichenden Bauteilneigungen noch gleichwertig gegeben ist. Andernfalls bietet der Normenentwurf die Möglichkeit die reduzierte thermische Schutzwirkung des RBS im Assessment zu berücksichtigen. Die Ergebnisse aus dem Forschungsvorhaben wurden bereits auf einem wissenschaftlichen Symposium vorgestellt sowie in einer referierten Fachzeitschrift publiziert. Ferner wurden die Informationen zum Forschungsprojekt und dem Normenentwurf im Rahmen eines Anwenderworkshops interessierten Kreisen zugänglich gemacht. Der im Projekt ausgearbeitete Normenentwurf wird dem zuständigen europäischen Normungsgremien, CEN/TC 127/WG 1, zur Verfügung gestellt und dort zur Abstimmung gestellt. KW - Normung KW - Reaktives Brandschutzsystem KW - Stahl KW - Zugglied KW - Feuerwiderstand KW - Brandversuche PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-569363 SP - 1 EP - 57 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-56936 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Fürst, Richard A1 - Häßler, Dustin A1 - Hothan, Sascha T1 - Brandversuch eines Stahlzuggliedes mit reaktivem Brandschutzsystem N2 - Das Poster stellt den im Rahmen des Workshops "Feuerwiderstand von Stahlzuggliedern mit reaktiver Brandschutzbeschichtung" durchgeführten Brandversuch vor. T2 - Workshop - Feuerwiderstand von Stahlzuggliedern mit reaktiver Brandschutzbeschichtung CY - Berlin, Germany DA - 06.09.2022 KW - Brandschutz KW - Brandversuch KW - Feuerwiderstand KW - Reaktives Brandschutzsystem PY - 2022 AN - OPUS4-55699 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -