TY - JOUR A1 - Raysyan, Anna A1 - Moerer, R. A1 - Coesfeld, Bianca A1 - Eremin, S. A1 - Schneider, Rudolf T1 - Fluorescence polarization immunoassay for the determination of diclofenac in wastewater N2 - Pharmacologically active compounds are often detected in wastewater and surface waters. The nonsteroidal anti-inflammatory drug diclofenac (DCF) was included in the European watch list of substances that requires its environmental monitoring in the member states. DCF may harmfully influence the ecosystem already at concentrations ≤ 1 μg L−1. The fast and easy quantification of DCF is becoming a subject of global importance. Fluorescence polarization immunoassay (FPIA) is a homogeneous mix-and-read method which does not require the immobilization of reagents. FPIA can be performed in one phase within 20–30 min, making it possible to analyse wastewater without any complicated pre-treatment. In this study, new tracermolecules with different structures, linking fluorophores to derivatives of the analyte, were synthesized, three homologous tracers based on DCF, two including a C6 spacer, and one heterologous tracer derived from 5-hydroxy-DCF. The tracer molecules were thoroughly assessed for performance. Regarding sensitivity of the FPIA, the lowest limit of detection reached was 2.0 μg L−1 with a working range up to 870 μg L−1. The method was validated for real wastewater samples against LC-MS/MS as reference method with good agreement of both methods. KW - Abwasser KW - Umweltschadstoffe KW - Antikörper KW - Antibody PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-518398 DO - https://doi.org/10.1007/s00216-020-03058-w SN - 1618-2642 VL - 413 IS - 4 SP - 999 EP - 107 PB - Springer CY - Heidelberg AN - OPUS4-51839 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kittner, Maria A1 - Coesfeld, Bianca A1 - Schlau, Sven A1 - Werischak, Thomas A1 - Altmann, Korinna A1 - Kalbe, Ute T1 - Simultaneous sampling for microplastics and environmental contaminants from artificial turf: development of a new integrated microplastics eluate lysimeter N2 - To get a better understanding of potentially harmful contaminant emissions from soils or materials into the environment, politics demand practical and holistic sampling concepts for environmental samples such as leachates containing polycyclic aromatic hydrocarbons (PAH) or heavy metals, and hazardous particulate matter like microplastics (MP). Of particular concern are MP emissions from artificial turf sports pitches. So far, there has been only very limited data on MP mass emissions from artificial turf potentially posing a risk to the groundwater and no sampling device that allowed simultaneous sampling for dissolved and particulate contaminants. In this study, a novel integrative microplastics eluate lysimeter was developed to determine contaminant emissions from three artificial turf systems at different ageing states (fabric-new, artificially aged, real-time aged). For the accelerated ageing, all environmental simulation parameters were based on Central German conditions and simulated outdoor stress during the turf service lifespan of 15 years. MP masses from eluates were analysed using thermal extraction desorption-gas chromatography/mass spectrometry, PAH concentrations using gas chromatography/mass spectrometry and heavy metals using inductively coupled plasma-optical emission spectroscopy. Results showed that no PAH or heavy metal concentrations from the seepage water were above German legal limits for alternative granular construction materials considering soil and groundwater protection. Furthermore, it was found that only minimal MP emissions were released from new turf systems into the seepage water (< 1 mg/m2). Ageing of the artificial turf increased MP formation, especially from rubber infill and grass fibres, which are then carried into the seepage water. The highest total MP emissions over a simulated turf lifespan of 15 years were detected in two real-time aged turf systems ranging from 136.4–252.5 mg/m2. Considerably less total MP emissions were detected in accelerated aged artificial turf systems, one of which contained a synthetic rubber infill (5.4–8.0 mg/m2) and one without rubber infill (0.2–5.3 mg/m2). In summary, it was demonstrated that the newly developed MEL generated reliable and reproducible data and has thus proven itself as an integrated, straightforward and automated sampling device for simultaneous monitoring of particulate and dissolved pollutant emissions from simple soil matrices. KW - Lysimeter KW - Microplastics KW - Artificial turf KW - Thermal extraction desorption-gas chromatography/mass spectrometry KW - TED-GC/MS KW - Polycyclic aromatic hydrocarbons KW - PAH KW - Heavy metals KW - Soil samples PY - 2025 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-645301 DO - https://doi.org/10.1186/s12302-025-01235-1 SN - 2190-4715 VL - 37 IS - 1 SP - 1 EP - 15 PB - Springer Open AN - OPUS4-64530 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -