TY - CONF A1 - Feldkamp, Martin A1 - Nehrig, Marko A1 - Bletzer, Claus Wilhelm A1 - Musolff, André A1 - Wille, Frank T1 - Combustion of wood encapsulated in steel sheets during fire test N2 - Packages for the transport of radioactive material are often equipped with impact limiters consisting of wood, encapsulated by Steel sheets. These impact limiters shall ensure the transport cask meets the IAEA safety requirements. After damage caused by the mechanical tests the package has to withstand a severe fire scenario. According to the regulations during and following the fire test, the specimen shall not be artificially cooled and any combustion of materials of the package shall be permitted to proceed naturally. Due to results of the French institute IRSN it was shown that after the fire test an additional energy supply from a pre-damaged impact limiter should be taken into account. The combustion or smouldering of wood was of interest. BAM started a first test phase to examine the issue of combustion for such kind of package components. The goal was to understand the phenomena under the consideration of relevant regulatory boundary conditions. Several metal buckets were filled with wood and equipped with thermocouples. The test specimens have been prepared with different damage arrangements to take the influence of the mechanical tests into account. This paper shows the experimental Setup and the conduction of the tests. The first test shows that pre-damaged metal encapsulations can lead to smouldering of the wood and with this to a Supplement energy release after the end of the 30 minute fire. The consequence could be, to consider additional thermal loads of wood filled impact limiters to filled the IAEA regulations, if the conditions of the tests are transferable to the safety analysis of the package design. T2 - RAMTRANS 2015 - 10th International conference on radioactive materials transport and storage CY - Oxford, UK DA - 19.05.2015 KW - Typ-B KW - Impact limiter KW - Shock absorber KW - Wood KW - Thermal test KW - Fire test PY - 2015 SP - 1 EP - 9 AN - OPUS4-33407 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Feldkamp, Martin A1 - Nehrig, Marko A1 - Bletzer, Claus A1 - Musolff, André A1 - Erenberg, Marina A1 - Wille, Frank T1 - Behaviour of Wood Filled Impact Limiters during Fire Test N2 - Packages for the transport of radioactive material are often equipped with impact limiters consisting of wood, encapsulated by steel sheets. These impact limiters shall ensure the transport cask meets the mechanical and thermal IAEA regulatory test requirements. After damage caused by the mechanical tests the package has to withstand a severe fire scenario. According to the regulations during and following the thermal test, the specimen shall not be artificially cooled and any combustion of materials of the package shall be permitted to proceed naturally. Corresponding to results of the French institute IRSN combustion and smouldering of wood inside the impact limiter occurred during and after the fire test. An additional energy supply from a pre-damaged impact limiter to the cask could be the consequence for the safety assessment of the containment. BAM started a first test phase to examine the issue of combustion for such kind of package components. The goal was to understand the phenomena under the consideration of relevant regulatory boundary conditions. Several metal buckets were filled with wood and equipped with thermocouples. The test specimens have been prepared with different damage arrangements to take the influence of the mechanical tests into account. This paper shows the experimental setup and the conduction of the tests. The first test shows that pre-damaged metal encapsulations can lead to smouldering of the wood and with this to a supplement energy release after the end of the 30 minute fire. BAM is in the preparation process for a second test phase. A thermal test will take place with a wood filled test specimen weighing about 2Mg. T2 - The 18th International Symposium on the Packaging and Transportation of Radioactive Materials (PATRAM 2016) CY - Kobe, Japan DA - 18.09.2016 KW - Large scale testing KW - Fire test KW - Impact limiter KW - Shock absorber KW - Thermal test KW - Typ-B KW - Wood KW - Smouldering PY - 2016 SP - paper no. 1011 AN - OPUS4-37854 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Feldkamp, Martin A1 - Erenberg, Marina A1 - Nehrig, Marko A1 - Bletzer, Claus A1 - Musolff, André A1 - Schönfelder, Thorsten A1 - Wille, Frank T1 - Behavior of wood filled impact limiters during the IAEA thermal test N2 - Packages for the transport of radioactive material are often equipped with impact limiters consisting of wood, encapsulated by steel sheets. These impact limiters shall ensure that transport casks meet the IAEA safety requirements. After damage caused by the mechanical tests the package has to withstand a severe fire scenario. It is required that the mechanical tests have to produce maximum damage, taking into account the thermal test. Furthermore, any damage, which would give rise to increased radiation or loss of containment or affect the confinement system after the thermal test, should be considered. Concerning the thermal test, the IAEA safety requirements state that during and following the fire test, the specimen shall not be artificially cooled and any combustion of materials of the package shall be permitted to proceed naturally. Different works from the French Institute for Radiological Protection and Nuclear Safety (IRSN) and BAM show that additional energy supply from a pre-damaged impact limiter to the cask could occur caused by smoldering of the wood. This effect should be considered within the safety assessment of the package. A heat wave from the fire could overlap with the additional energy from the impact limiter in the sealing system. In 2015 BAM conducted small scale fire tests with wood filled metal drums showing continuing combustion processes during the cooling down phase. As not much is known about smoldering processes in wood filled impact limiters, it is highly complex to define pre-damage of impact limiters, which are conservative, regarding the most damaging energy flow from the impact limiter to the containment system in dependence of time. More research has to be done to develop models to examine the effects of smoldering impact limiters on the containment of packages for the assessment. The process of smoldering is described with regard to the requirements in the thermal safety assessment. Parameters influencing the smoldering process are identified. BAM operates test facilities to examine the issue of mechanical damage, combustion and heat transfer of packages for transport of radioactive material. A thermal test will take place with a wood filled test specimen with a diameter of about 2.3 meters. The aim is to understand the phenomena of smoldering under the consideration of relevant regulatory boundary conditions. T2 - ASME 2017 Pressure Vessels and Piping Conference (PVP2017) CY - Waikoloa, Hawaii, USA DA - 16.07.2017 KW - Fire test KW - Wood KW - IAEA KW - Smoldering KW - Smouldering KW - Shock absorber KW - Thermal test KW - Combustion KW - Impact limiter PY - 2017 SN - 978-0-7918-5802-8 VL - 7 SP - Article UNSP V007T07A038, 1 EP - 9 AN - OPUS4-43172 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Erenberg, Marina A1 - Bletzer, Claus A1 - Feldkamp, Martin A1 - Musolff, André A1 - Nehrig, Marko A1 - Wille, Frank T1 - Experimental investigations of the burning behaviour of transport package impact limiters and of fire spread impact onto the cask N2 - Accident safe packages for the transport of spent nuclear fuel and high-level waste shall fulfil international IAEA safety requirements. Compliance is shown by consecutive mechanical and thermal testing. Additional numerical analysis are usually part of the safety evaluation. For damage protection some package designs are equipped with wood filled impact limiters encapsulated by steel sheets. The safety of these packages is established in compliance with IAEA regulations. Cumulative mechanical and fire tests are conducted to achieve safety standards and to prevent loss of containment. Mechanical reliability is proven by drop tests. Drop testing might cause significant damage of the impact limiter steel sheets and might enable sufficient oxygen supply to the impact limiter during the fire test to ignite the wood filling. The boundary conditions of the fire test are precisely described in the IAEA regulatory. During the test the impact limiter will be subjected to a 30 minute enduring fire phase. Subsequent to the fire phase any burning of the specimen has to extinguish naturally and no artificial cooling is allowed. At BAM a large-scale fire test with a real size impact limiter and a wood volume of about 3m3 was conducted to investigate the burning behaviour of wood filled impact limiters in steel sheet encapsulation. The impact limiter was equipped with extensive temperature monitoring equipment. Until today burning of such impact limiters is not sufficiently considered in transport package design and more investigation is necessary to explore the consequences of the impacting fire. The objective of the large scale test was to find out whether a self-sustaining smouldering or even a flaming fire inside the impact limiter was initiated and what impact on the cask is resulting. The amount of energy, transferred from the impact limiter into the cask is of particular importance for the safety of heavy weight packages. With the intention of heat flux quantification a new approach was made and a test bench was designed. T2 - ASME 2018 Pressure Vessels and Piping Conference CY - Prague, Czech Republic DA - 15.07.2018 KW - Shock absorber KW - Impact limiter KW - Wood KW - Thermal testing KW - Fire KW - Smoldering KW - IAEA KW - Fire test PY - 2018 SN - 978-0-7918-5170-8 VL - PVP2018 SP - 84714-1 EP - 84714-10 AN - OPUS4-46984 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nehrig, Marko A1 - Erenberg, Marina A1 - Feldkamp, Martin A1 - Bletzer, Claus A1 - Musolff, André A1 - Wille, Frank T1 - Large Scale IAEA Thermal Test with Wood filled Impact Limiters N2 - Packages for the transport of radioactive material are often equipped with impact limiters consisting of wood. Mostly this wood is encapsulated by steel sheets. The impact limiters are needed to ensure that the transport casks meet the IAEA safety requirements. According to the IAEA safety requirements a package has to withstand consecutively severe mechanical tests followed by a thermal test. The mechanical tests have to produce maximum damage concerning the thermal test. Following this, the impact limiters may have serious pre-damage when the thermal tests begins. The IAEA safety requirements state that during and following the fire test, the specimen shall not be artificially cooled and any combustion of materials of the package shall be permitted to proceed naturally. Small scale fire tests with wood filled metal drums by BAM and works of the French Institute for Radiological Protection and Nuclear Safety (IRSN) showed that pre-damaged steel encapsulated wooden structures could start smoldering initiated by the thermal test. These processes supply additional energy to the cask which should be considered within the safety assessment of the package. As not much is known about smoldering processes in encapsulated wooden structures with a reduced oxygen supply the need for a test was identified. To investigate the influence of a smoldering impact limiter concerning the amount of energy supplied to the cask in dependence of the time BAM conducted a large scale impact limiter thermal test. For that, a pre-damaged impact limiter with a diameter of 2,3 m was mounted on a water tank simulating a cask. A complex system of a regulated pump, a heater, a cooler, a slide valve, a flow meter and numerous thermocouples were installed and connected to a control unit to ensure all needed operating conditions. After a pre-heating compared to typical SNF decay-heat, the 30 min lasting fire phase of the thermal test was started. After that, the expected and initiated smoldering began. The results of the large scale test are presented in this poster. Systematic small scale tests will follow to identify the influence of different parameters, e.g. moisture content and scale effects. The tests took place at BAM Test Site for Technical Safety (TTS) with its various possibilities for mechanical and thermal tests. The results of these tests will have direct influence in the safety assessment of transport cask for the transport of radioactive material T2 - 2018 WM Symposia CY - Phoenix, AZ, USA DA - 18.03.2018 KW - Type-B Package KW - Thermal Test PY - 2018 SP - Paper 18257, 1 EP - 11 AN - OPUS4-45311 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bletzer, Claus T1 - CONFIRE Temperture development during fire test of a final storagr container Typ V N2 - This presentation focusses on the thermal test of a typical storage container design for the German final storage repository KONRAD. The preparation of the container, the conduction of the fire test itself and results like the temperature evolution and as-sumptions for thermal material properties are shown. As thermal test final storage containers have to be exposed to a fire of 800 °C (1472 °F) for 1 hour according to the final storage conditions provided by the federal com-pany for radioactive waste disposal (BGE). The here discussed cask contains a steel covered concrete layer of a thickness of 100/150 mm. Heating up concrete is a highly nonlinear process since the vaporization of residual water consumes high amounts of thermal energy and produce vast amounts of steam. The constantly measured temperatures provide the basis to adjust common models of thermal properties for concrete esp. for FEAs. Finally in a later step this will allow predictions of similar designed container with different sizes. T2 - SNL BAM Workshop CY - Albuquerque, NM, USA DA - 14.03.2018 KW - KONRAD KW - Fire testing KW - Concrete KW - Final storage KW - Thermal properties PY - 2018 AN - OPUS4-45427 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Sterthaus, Jens A1 - Ballheimer, Viktor A1 - Bletzer, Claus Wilhelm A1 - Linnemann, Konrad A1 - Nehrig, Marko A1 - Wille, Frank T1 - Numerical approach for containment assessment of transport packages under regulatory thermal test conditions N2 - The requirements of the IAEA safety standards for Type B(U) packages include the thermal test as part of test sequences that represents accident conditions of transport. In comparison to mechanical tests, e.g., 9 m drop onto an unyielding target with short impact durations in a range of approximately 10 ms to 30 ms, the extended period of 30 min is defined in regulations for exposure of a package to a fire environment. Obviously, the required containment capability of the package has to be ensured not only after completing the test sequence but also over the course of the fire test scenario. Especially, deformations in the sealing area induced by the non-uniform thermal dilation of the package can affect the capability of the containment system. Consequently, thermo-mechanical analyses are required for the assessment. In this paper some aspects of finite element analysis (FEA) of transport packages with bolted closure systems under thermal loading are discussed. A generic FE model of a cask is applied to investigate the stress histories in the bolts, lid, and cask body as well as the deformations in the sealing area and the compression conditions of the gasket. Based on the parameter variations carried out, some recommendations in regard to modeling technique and results interpretation for such kind of analyses are finally given. T2 - PVP2014 - ASME 2014 Pressure vessels & piping division conference CY - Anaheim, CA, USA DA - 20.07.2014 KW - Transport packages KW - Containment KW - Thermo-mechanical analyses KW - FEA KW - Gasket PY - 2014 SN - 978-0-7918-4600-1 DO - https://doi.org/10.1115/PVP2014-28199 VL - 3 SP - 28199, 1 EP - 14 AN - OPUS4-32349 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bletzer, Claus Wilhelm T1 - Severe fire scenarios for radioactive waste storage packages T2 - Fire Science Workshop CY - Berlin, Germany DA - 2013-11-29 PY - 2013 AN - OPUS4-30974 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nehrig, Marko A1 - Feldkamp, Martin A1 - Bletzer, Claus Wilhelm A1 - Wille, Frank T1 - Thermal test driven pressure build-up inside type-B packages containing wet radioactive waste N2 - In recent years several German approval procedures for ductile cast iron transport containers containing wet intermediate level waste were conducted. BAM, as one of the German competent authorities, was involved in the complex design assessment work with this specific issue. Thermal analysis is one part of the authority assessment work done by BAM in Germany. The radioactive contents of package designs which were not dried, only drained, consist of saturated ion exchange resin and a small amount of free water. Compared to the safety assessment of packages with dry content, attention must be paid to some more specific points. The most interesting point, however, is the pressure build-up inside the package due to vaporization. This could be caused by radiolysis of the liquid and must be taken into account for the storage period. The inner pressure of the package leads to mechanical loads to the package body, the lid and the lid bolts. Thus, the pressure is the driving force on the gasket system regarding the activity release and a possible loss of tightness. The paper deals primarily with the pressure build-up inside the package caused by the transport regulatory thermal test (30 min at 800 °C) as part of the cumulative test scenario under accident conditions of transport. The pressure build-up is estimated by calculation in a very conservative way regarding conduction and heat radiation. Furthermore the paper discusses a conservative approach for the estimation of the resulting pressure depending on the percentage of water inside the cask. To get trustworthy results without an exact specification of the content, experimental fire tests should be conducted. However, this paper shows the difficulties of assessing casks containing wet content. From the authority assessment point of view, drying of the content could be an effective way to avoid the above described pressure build-up and the associated difficulties for the safety assessment. T2 - PATRAM 2013 - 17th International symposium on the packaging and transportation of radioactive materials CY - San Francisco, CA, USA DA - 18.08.2013 KW - Type-B KW - Wet content KW - Pressure build-up KW - Radioactive waste KW - Thermal test PY - 2013 SP - Paper 108, 1 EP - 10 PB - Omnipress AN - OPUS4-30197 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Feldkamp, Martin A1 - Erenberg, Marina A1 - Nehrig, Marko A1 - Bletzer, Claus A1 - Musolff, André A1 - Wille, Frank A1 - Schönfelder, Thorsten T1 - Aspects of assessment of packages with wood filled impact limiters during fire tests N2 - Packages for the transport of radioactive material are often equipped with impact limiters consisting of wood, encapsulated by steel sheets. These impact limiters shall ensure that the transport casks meet the mechanical and thermal IAEA regulatory test requirements. According to the accident conditions of transport it is mandatory to expose the specimens to a cumulative effect by mechanical and thermal impacts. The mechanical tests consist of a free drop from 9 m onto a flat unyielding target and a 1 m drop onto a puncture bar. After damage caused by mechanical test sequences the package has to withstand a severe fire scenario. Corresponding to the IAEA advisory material it is required that the impact attitudes for the 9 m drop test and for the puncture test have to be such as to produce maximum damage, taking into account the thermal test. Moreover, any damage, which would give rise to increased radiation or loss of containment or affect the confinement system after the thermal test, should be considered. During and following the thermal test, the specimen shall not be artificially cooled and any combustion of materials of the package shall be permitted to proceed naturally. Different works from the French Institute for Radiological Protection and Nuclear Safety (IRSN) and BAM show that additional energy supply from a pre-damaged impact limiter to the cask could occur. This effect should be considered within the safety assessment of the containment. Thermal effects at the closure system of the cask, which might result in an elevated activity release, have to be excluded. BAM conducted small scale tests with wood filled metal buckets showing continuing combustion processes during the cooling down phase. These test results are presented. As not much is known about smouldering processes in wood filled impact limiters, it is highly complex to define pre-damage of impact limiters, which are conservative, regarding the maximum damaging energy flow from the impact limiter to the containment system. More research has to be done to develop models to examine the effects of smouldering impact limiters on the containment of packages for the transport of radioactive material. Aspects of assessment and its difficulties are shown. BAM as a competent authority for the approval of transport casks for radioactive material in Germany operates the test facilities to examine the issue of mechanical damage, combustion and heat transfer for such kind of package systems. For this purpose the knowledge from real drop tests with casks of a mass partly over 100 tons was transferred to a test application. A thermal test will take place with a wood filled test specimen with a diameter of about 2.3 meters. The aim is to understand the phenomena of smouldering under the consideration of relevant regulatory boundary conditions. The process of smouldering is described with regard to the requirements in the thermal assessment of safety of packages for the transport of radioactive material. Requirements concerning the pre-damage of packages for the maximum damage of impact limiters are discussed. Parameters influencing the smouldering process are identified. T2 - WM 2017 Conference CY - Phoenix, AZ, USA DA - 05.03.2017 KW - Fire test KW - Wood KW - Combustion KW - Smouldering KW - Smoldering KW - Impact limiter KW - Shock absorber KW - Thermal test KW - IAEA PY - 2017 SN - 978-0-9828171-6-2 SP - 1 AN - OPUS4-40157 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bletzer, Claus Wilhelm T1 - Strategie zur Bestimmung von Temperaturen von Transport- und Lagerbehältern für radioaktive Stoffe T2 - Jahrestagung Kerntechnik 2010 CY - Berlin, Germany DA - 2010-05-04 PY - 2010 AN - OPUS4-21320 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bletzer, Claus W. A1 - Zencker, Uwe A1 - Völzke, Holger A1 - Nehrig, Marko T1 - Strategien zur Bestimmung von Temperaturen von Transport- und Lagerbehältern für radioaktive Stoffe T2 - Jahrestagung Kerntechnik 2010 CY - Berlin, Deutschland DA - 2010-05-04 KW - Temperaturprofil KW - Transportbehälter KW - Radioaktive Stoffe PY - 2010 IS - Section 5 / Paper 514 SP - 1 EP - 6 CY - Berlin AN - OPUS4-22604 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bletzer, Claus Wilhelm A1 - Zencker, Uwe A1 - Völzke, Holger A1 - Koch, Frank T1 - Asymmetrische Temperaturprofile in Transport- und Lagerbehältern für radioaktive Stoffe T2 - Jahrestagung Kerntechnik CY - Dresden, Deutschland DA - 2009-05-12 KW - Temperaturprofil KW - CFD-Berechnung KW - Transportbehälter KW - Radioaktive Stoffe PY - 2009 SP - 1 EP - 5(?) CY - Dresden AN - OPUS4-19431 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bletzer, Claus W. T1 - Asymmetrische Temperaturprofile in Transport- und Lagerbehälter für radioaktive Stoffe T2 - Jahrestagung Kerntechnik, Annual Meeting on Nuclear Technology 2009 CY - Dresden, Germany DA - 2009-05-12 PY - 2009 AN - OPUS4-19469 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Koch, Frank A1 - Bletzer, Claus Wilhelm A1 - Wieser, Günter T1 - Consideration of asymmetrical heat transmission and distribution using numerical methods T2 - PATRAM 2007, 15th International Symposium on the Packaging and Transportation of Radioactive Materials CY - Miami, Florida, USA DA - 2007-10-21 KW - Temperaturverteilung KW - CFD KW - FEA KW - Transportbehälter KW - Wärmeübergang PY - 2007 SP - 1 EP - 8 PB - Institute of Nuclear Materials Management AN - OPUS4-16131 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nehrig, Marko A1 - Bletzer, Claus Wilhelm A1 - Wille, Frank T1 - Pressure build-up inside packages containing wet intermediate level radioactive waste due to thermal loads N2 - Over the last years several transport approval procedures were finished for ductile cast iron containers containing wet intermediate level waste. BAM was involved in the assessment of mechanical and thermal aspects, activity release and material and component behavior regarding fulfillment of the regulatory requirements. The radioactive contents of these package designs which were not dried, only drained, consist of saturated ion exchange resin and a small amount of free water. Regarding wet contents, the most interesting point, however, is the pressure build-up inside the package due to vaporization. This could be aused by radiolysis of the liquid and must be taken into account for the storage period. The paper deals primarily with the pressure build-up inside the package aused by the regulatory thermal test (30 min at 800°C) as part of the cumulative test scenario under accident conditions of transport. The pressure build-up is estimated by calculation in a very conservative way regarding conduction and heat radiation. To get trustworthy results without an exact specification of the content, physical fire tests should be conducted. This paper will result in the strong advice, that contents should be dried to ensure a positive outcome of the safety assessment. T2 - ASME 2012 Pressure vessels & piping division conference CY - Toronto, Ontario, Canada DA - 15.07.2012 KW - Radioactive material KW - Pressure build-up KW - Wet intermediate level waste PY - 2012 SP - PVP2012-78282, 1-6 PB - American Society of Mechanical Engineers CY - New York AN - OPUS4-26321 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Feldkamp, Martin A1 - Nehrig, Marko A1 - Bletzer, Claus Wilhelm A1 - Wille, Frank T1 - Pressure build-up during the fire test in type B(U) packages containing water - 13280 N2 - The safety assessment of packages for the transport of radioactive materials with content containing liquids requires special consideration. The main focus is on water as supplementary liquid content in Type B(U) packages. A typical content of a Type B(U) package is ion exchange resin, waste of a nuclear power plant, which is not dried, normally only drained. Besides the saturated ion exchange resin, a small amount of free water can be included in these contents. Compared to the safety assessment of packages with dry content, attention must be paid to some more specific issues. An overview of these issues is provided. The physical and chemical compatibility of the content itself and the content compatibility with the packages materials must be demonstrated for the assessment. Regarding the mechanical resistance the package has to withstand the forces resulting from the freezing liquid. The most interesting point, however, is the pressure build-up inside the package due to vaporization. This could for example be caused by radiolysis of the liquid and must be taken into account for the storage period. If the package is stressed by the total inner pressure, this pressure leads to mechanical loads to the package body, the lid and the lid bolts. Thus, the pressure is the driving force on the gasket system regarding the activity release and a possible loss of tightness. The total pressure in any calculation is the sum of partial pressures of different gases which can be caused by different effects. The pressure build-up inside the package caused by the regulatory thermal test (30 min at 800 deg. C), as part of the cumulative test scenario under accident conditions of transport is discussed primarily. To determine the pressure, the temperature distribution in the content must be calculated for the whole period from beginning of the thermal test until cooling-down. In this case, while calculating the temperature distribution, conduction and radiation as well as evaporation and condensation during the associated process of transport have to be considered. This paper discusses limiting amounts of water inside the cask which could lead to unacceptable pressure and takes into account saturated steam as well as overheated steam. However, the difficulties of assessing casks containing wet content will be discussed. From the authority assessment point of view, drying of the content could be an effective way to avoid the above described pressure build-up and the associated difficulties for the safety assessment T2 - WM2013 Conference CY - Phoenix, Arizona, USA DA - 24.02.2013 KW - Fire test KW - B(U) KW - Thermal test KW - Pressure KW - Water PY - 2013 SN - 978-0-9836186-2-1 SP - 1 EP - 12(?) CY - Phoenix, Arizona, USA AN - OPUS4-27997 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bletzer, Claus Wilhelm T1 - Pressure Build Up in Casks Containing Wet Waste T2 - KONTEC 2013, 11. Internationales Symposium "Konditionierung radioaktiver Betriebs- und Stilllegungsabfälle" CY - Dresden, Germany DA - 2013-03-13 PY - 2013 AN - OPUS4-28014 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bletzer, Claus Wilhelm A1 - Nehrig, Marko A1 - Feldkamp, Martin A1 - Wille, Frank A1 - Völzke, Holger T1 - Druckaufbau in Behältern mit feuchtem Inventar N2 - Beim Betrieb von Kernkraftwerken fallen kontaminierte feuchte Abfallstoffe, wie z. B. Ionenaustauscherharze an, die in Transport- und Lagerbehältern der Entsorgung zugeführt werden. In Deutschland ist die BAM die zuständige Behörde für die Bauartprüfung von Typ B-Versandstücken. Im Zulassungsverfahren wird die Einhaltung der Schutzziele solcher Verpackungen überprüft. Basis für die Bewertung sind hierbei nationale und internationale gesetzliche Grundlagen sowie Regularien, welche in direkter Linie auf den IAEA SSR-6 [1] basieren. Die BAM ist ebenfalls im Rahmen einer Verwaltungsvereinbarung durch das BfS mit der Behälterbauartprüfung sowie der Beurteilung der qualitätssichernden Maßnahmen auf Grundlage von Kapitel 7 in [3] beauftragt. Typ-B(U) Verpackungen dienen zur Aufnahme verschiedenster radioaktiver oder radioaktiv kontaminierter Inhalte wie Brennelemente, Core-Bauteile, Rückbaurückstände oder belasteter Reinigungs- und Hilfsstoffe. In den meisten Fällen werden trockene bzw. getrocknete Inhalte verpackt. Potentiell feuchte oder nasse Inhalte wie z.B. Verdampferkonzentrate werden oftmals innerhalb der Verpackung getrocknet und können somit als trockene Inhalte behandelt werden. Beladene Ionenaustauscherharze werden i.d.R. mittels Transportwasser in die Verpackung eingespült und nur entwässert, aber nicht getrocknet. Die BAM war bereits in verschiedenen Zulassungsverfahren für Behälter mit feuchtem radioaktivem Inventar involviert. Bezüglich des Konrad Endlagers sind solche Verpackungen für feuchte, nicht Wärme entwickelnden Inhalte in der Regel als „Störfallfest verpackte Abfälle der Abfallbehälterklasse II [ABK II] mit spezifizierter Leckrate“ klassifiziert. In diesem Beitrag soll direkt Bezug zu den thermischen Prüfungen genommen werden. Im Transportfall sind hierbei die Unfallbeförderungsbedingungen zu unterstellen, die neben den mechanischen Prüfungen ein den Behälter vollständig einhüllendes Feuer von mindestens 800°C über 30 Minuten sowie der notwendigen Abkühldauer vorschreiben. Für eine geplante Endlagerung der Behälter ist im Zuge der Endlager-Bauartprüfung eine Branddauer von 60 Minuten mit nachfolgender 24-stündiger Abkühlphase unter abweichenden Randbedingungen gegenüber den verkehrsrechtlichen Regelwerksanforderungen zu beachten ([2] Kap. 5.3.). Bei einer möglichen Vorgehensweise zur Bestimmung des Druckaufbaus in einem Behälter aus den vorgeschriebenen Feuertests wird zuerst die Temperaturverteilung im Inhalt über den Zeitraum des Brands sowie der Abkühlphase berechnet. Der hier betrachtete Inhalt, der lediglich entwässert, aber nicht getrocknet ist, besteht sowohl aus gesättigtem Ionenaustauscherharz als auch aus einem geringen Anteil an freiem Wasser. Die Verdampfung von Wasser ist dabei ein kritischer Prozess der zum Druckaufbau im Behälter führt. Zur Einschätzung der aus dem thermischen Lastfall resultierenden Beanspruchungen des Behälters bis hin zur Gefährdung seiner Dichtheit und Integrität können sowohl rechnerische, als auch experimentelle Methoden Anwendung finden. Während sich die durch eine Brandbeanspruchung einstellenden Temperaturen in der Verpackung relativ genau berechnen lassen, erweist sich die Bestimmung der Temperatur- und Druckverteilung im Inventar aufgrund des komplexen thermischen und strömungsdynamischen Verhaltens als Herausforderung. Dabei ist der Wärmeübergang von der Behälterinnenwand in das Inventar sowie das thermische Verhalten des Inventars als inhomogen zu erhitzendes Gemisch aus Feststoffen, Fluiden (z.B. Wasser) und Gasen sehr komplex. Diese Vorgänge bestimmen jedoch den resultierenden und für die Sicherheitsbewertung maßgebenden Druckaufbau im Behälterinnenraum. Unter Berücksichtigung von Konvektion, Wärmeleitung und -strahlung werden thermische Zustände für den gewählten generischen Behälter aufgezeigt und die Effekte hinsichtlich Verdampfung und Druckaufbau erklärt. Anschließend werden zwei Ansätze zur Bestimmung des Partialdrucks durch Verdampfung im Behälter aufgezeigt. Para 663 und Para 664 der IAEA SSR-6 [1] der Transportbedingungen besagen, das - je nach Auslegung - der Feuertest bereits mit einem Innendruck von bis zu 700 kPa begonnen wird. Die beim Feuertest entstehenden Überdrücke müssen dann zum max. Auslegungsdruck hinzugefügt werden und der Behälter muss den Nachweis der Integrität mit den durch die Hitze reduzierten Werkstoffkennwerten des Behälters (Körper, Deckel, Verschlusssystem, Dichtung) nach der Vorschädigung durch die mech. Unfalltests erbringen. Bezüglich der Endlagerung besagt die Endlagerungsbestimmung [3] in Kap. 7.1.4.2.4, dass das “…Abfallprodukt so beschaffen sein muss, das bei der gemäß Unterkapitel 7.1.5.6 durchzuführenden thermischen Prüfung der maximal auftretende Innendruck 15 bar beträgt.”. T2 - KONTEC 2013 - 11. Internationales Symposium 'Konditionierung radioaktiverBetriebs- und Stilllegungsabfälle' CY - Dresden, Germany DA - 13.0,3.2013 KW - Druckaufbau KW - Radioaktive Abfälle KW - Endlager PY - 2013 IS - Sektion 4 / Vortrag 031 SP - 1 EP - 11 AN - OPUS4-28094 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bletzer, Claus Wilhelm A1 - Nehrig, Marko A1 - Feldkamp, Martin A1 - Wille, Frank A1 - Völzke, Holger T1 - Pressure build up in casks containing wet waste T2 - KONTEC 2013 - 11. Internationales Symposium 'Konditionierung radioaktiverBetriebs- und Stilllegungsabfälle' CY - Dresden, Germany DA - 2013-03-13 KW - Pressure build up KW - Radioactive waste KW - Disposal PY - 2013 IS - Sektion 4 / Vortrag 031 SP - 1 EP - 10(?) AN - OPUS4-28095 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nehrig, Marko A1 - Bletzer, Claus Wilhelm A1 - Wille, Frank T1 - Safety assessment aspects of type B(U) packages containing wet intermediate level waste N2 - In Germany, the mechanical and thermal safety assessment of approved packages for the transport of RAM is carried out by BAM as the competent authority according to the International Atomic Energy Agency regulations. BAM was involved in several approval procedures with ductile cast iron containers containing wet intermediate level waste. These contents, which are not dried, only drained, consist of saturated ion exchange resin and a small amount of free water. Compared to the safety assessment of packages with dry content, attention must be paid to some more specific points. The physical and chemical compatibility of the content itself and of the content with materials of the package must be shown. From the mechanical resistance point of view, the package has to withstand the forces resulting from the freezing liquid. The most interesting point, however, is the pressure build-up inside the package due to vapourisation. This could be caused by radiolysis of the liquid and must be taken into account for the storage period. The paper deals primarily with the pressure build-up inside the package caused by the regulatory thermal test (30 min at 800°C) as part of the cumulative test scenario under accident conditions of transport. To determine the pressure, the temperature distribution in the content must be calculated for the whole period from the beginning of the thermal test until cooling down. In this case, calculating the temperature distribution requires, besides the consideration of conduction and heat radiation, consideration of evaporation and condensation including the associated processes of transport. KW - Type B KW - Wet content KW - Pressure build-up KW - Vapourisation KW - Thermal test KW - Radioactive waste KW - Thermal analysis PY - 2012 DO - https://doi.org/10.1179/1746510913Y.0000000024 SN - 1746-5095 SN - 1746-5109 SN - 0957-476X VL - 23 IS - 3-4 SP - 187 EP - 190 PB - Ramtrans Publ. CY - Ashford AN - OPUS4-29935 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nehrig, Marko A1 - Bletzer, Claus Wilhelm A1 - Wille, Frank T1 - Safety assessment aspects of type B(U) packages containing wet intermediate level waste N2 - In Germany, the mechanical and thermal safety assessment of approved packages for the transport of RAM is carried out by BAM as the competent authority according to the International Atomic Energy Agency regulations. BAM was involved in several approval procedures with ductile cast iron containers containing wet intermediate level waste. These contents, which are not dried, only drained, consist of saturated ion exchange resin and a small amount of free water. Compared to the safety assessment of packages with dry content, attention must be paid to some more specific points. The physical and chemical compatibility of the content itself and of the content with materials of the package must be shown. From the mechanical resistance point of view, the package has to withstand the forces resulting from the freezing liquid. The most interesting point, however, is the pressure build-up inside the package due to vapourisation. This could be caused by radiolysis of the liquid and must be taken into account for the storage period. The paper deals primarily with the pressure build-up inside the package caused by the regulatory thermal test (30 min at 800°C) as part of the cumulative test scenario under accident conditions of transport. To determine the pressure, the temperature distribution in the content must be calculated for the whole period from the beginning of the thermal test until cooling down. In this case, calculating the temperature distribution requires, besides the consideration of conduction and heat radiation, consideration of evaporation and condensation including the associated processes of transport. T2 - RAMTRANSPORT 2012 - 9th International Conference on the Radioactive Materials Transport and Storage CY - London, UK DA - 22.05.2012 KW - Radioactive materials KW - Safety assessment KW - Pressure build-up KW - Wet intermediate level waste PY - 2012 SP - 1 EP - 7 AN - OPUS4-26314 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -