TY - JOUR A1 - Palkowski, Carsten A1 - Schwarzenberg, S. A1 - Simo, Anne T1 - Seasonal cooling performance of air conditioners: The importance of independent test procedures used for MEPS and labels JF - International Journal of Refrigeration N2 - Minimum energy performance standards and labels are commonly used tools to reduce the household energy use thus mitigating greenhouse gas emissions. However, the technical foundation for minimum energy performance standards and labels are test procedures for rating and testing of appliances. To de- termine the seasonal cooling performance of air conditioners, the current test standards require fixing of the compressor speed of the units to achieve steady-state conditions; this way of operation, how- ever, differs from real-life use. To make the seasonal cooling performance testing better reflect the real use conditions, this study proposes a compensation method which can be conducted independently from manufacturer data and still allows modulation of the tested units. Our results show that the tested units behave differently under part-load conditions, which results in a lower energy efficiency rating for some of the tested devices. KW - Air conditioner KW - Independent test method KW - Real use behavior KW - Seasonal energy efficiency ratio KW - Minimum energy performance standards KW - Energy label PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-485813 DO - https://doi.org/10.1016/j.ijrefrig.2019.05.021 SN - 0140-7007 VL - 104 SP - 417 EP - 425 PB - Elsevier AN - OPUS4-48581 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -