TY - CONF A1 - Goedecke, Caroline A1 - Altmann, Korinna A1 - Eisentraut, Paul A1 - Bannick, C. G. A1 - Braun, Ulrike T1 - Mikroplastik - Suchen und Finden N2 - Der Vortrag stellt spektroskopische und neue thermoanalytische Verfahren zum Nachweis von Mikroplastik in Umweltproben vor. Ein spezieller Fokus liegt auf dem neu entwickelten Verfahren der TED-GC-MS. Zusätzlich wird gezeigt, wie die TED-GC-MS eingesetzt werden kann, um Reifen in der Umwelt zu bestimmen. T2 - Fachforum Ressourcen - Kunststoffe und Nachhaltigkeit CY - Leverkusen, Germany DA - 06.11.2018 KW - Mikroplastik KW - TED-GC-MS KW - Thermoanalytische Verfahren KW - Spektroskopische Verfahren PY - 2018 AN - OPUS4-46652 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Goedecke, Caroline A1 - Eisentraut, Paul A1 - Kittner, Maria A1 - Altmann, Korinna A1 - Müller, Axel A1 - Braun, Ulrike T1 - Analysis of microplastics in theory and in practice N2 - Due to the favorable properties of polymers, their production and thus their input into the environment has increased significantly in recent decades. Currently, FTIR or Raman spectroscopy are mainly applied for the analysis of microplastic particles (MP) in environmental samples. However, these methods have great difficulties in determining metrologically traceable MP values, especially with regard to the limiting values, as preferred in regulation. Therefore, we developed a systematic and fast thermoanalytical method called TED-GC-MS (thermal extraction desorption gas chromatography mass spectrometry), which determines mass contents. Now the current goal is the determination of its process parameters. This poster illustrates the theoretical requirements for MP analysis (left side) and contrast them with the current state of research (right side).Unexpected practical problems are presented and the relatively new method is discussed concerning the quality requirements of well-established methods such as LC-or GC-MS. T2 - Eurachem Workshop - Uncertainty from sampling and analysis for accredited laboratories CY - Berlin, Germany DA - 19.11.2019 KW - Microplastics KW - TED-GC-MS KW - Reference materials PY - 2019 AN - OPUS4-49665 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Goedecke, Caroline A1 - Altmann, Korinna A1 - Bannick, C. G. A1 - Obermaier, N. A1 - Venghaus, D. A1 - Barjenbruch, M. A1 - Lau, P. A1 - Herper, D. A1 - Braun, Ulrike T1 - Optimierte Materialien und Verfahren zur Entfernung von Mikroplastik aus dem Wasserkreislauf N2 - Das Ziel dieses Projektes ist die Entwicklung neuer Materialien, um den Rückhalt von Mikroplastik-Partikeln (MP) aus verschiedenen urbanen Eintragspfaden (Kläranlagenablauf, Mischwasserüberlauf und Straßenabfluss)zu optimieren. Die im Rahmen des Projekts entwickelten Materialien sollten auf ihre Rückhaltefähigkeit von MP aus dem Kläranlagenklarlauf getestet werden. Für die Probenahme sowie für die Analytik wurden die entwickelten und optimierten Probenahme- sowie Analysetechniken angewendet. T2 - Konferenz der BMBF-Fördermaßnahme "MachWas-Materialien für die nachhaltige Wasserwirtschaft" CY - Frankfurt am Main, Germany DA - 29.05.2018 KW - Mikroplastik KW - TED-GC-MS KW - Mischwasser KW - Straßenablauf PY - 2018 AN - OPUS4-45043 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Goedecke, Caroline A1 - Altmann, Korinna A1 - Bannick, Claus Gerhard A1 - Braun, Ulrike A1 - Obermaier, N. T1 - Optimierte Materialien und Verfahren zur Entfernung von Mikroplastik aus dem Wasserkreislauf N2 - Das Ziel des OEMP-Projektes ist die Entwicklung neuer Materialien, um den Rückhalt von Mikroplastik-Partikeln (MP) aus verschiedenen urbanen Eintragspfaden (Kläranlagenablauf, Mischwasserüberlauf und Straßenabfluss) zu optimieren. Grundlage für die Bewertung ist die Entwicklung von geeigneten Untersuchungsverfahren (Probennahme, Probenaufbereitung, Detektion) zur Qualifizierung und Quantifizierung von MP in den relevanten Umweltmatrices. Diese Verfahren müssen zeiteffizient und zuverlässig sein. T2 - Statusseminar der BMBF-Fördermaßnahme „MachWas – Materialien für eine nachhaltige Wasserwirtschaft“ CY - Frankfurt am Main, Germany DA - 25.04.2017 KW - Mikroplastik KW - TED-GC-MS KW - Umweltproben PY - 2017 AN - OPUS4-40263 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Goedecke, Caroline A1 - Altmann, Korinna A1 - Eisentraut, Paul A1 - Paul, Andrea A1 - Barthel, A. K. A1 - Bannick, C. G. A1 - Lau, P. A1 - Venghaus, D. A1 - Barjenbruch, M. A1 - Braun, Ulrike T1 - Detection of microplastic and tire wear particles in road run-off samples using TED-GC-MS N2 - Plastics and rubber are used in many applications, such as packaging, building, construction and mobility. Due to their favourable properties like light weight, flexible processing and low costs their production and consequently their input into the environment has increased significantly over the last decades. In the environment, oxidation processes and mechanical abrasion lead to the decomposition of these plastics into small fragments, called microplastic (< 5 mm). By definition, microplastics only involve thermoplastics and duroplastics but elastomers made out of synthetic polymers (e. g. styrene butadiene rubber), modified natural polymers (e. g. natural rubber) and products of synthetic polymers (e. g. tires) are also part of the current microplastic discussion. The main entry pathway of rubber into the environment is the wear of used tire treads in road traffic. Lassen et al. showed that 60 % of the microplastic emissions in Denmark into the environment come from secondary microplastics generated by tires. Rain events can cause microplastic and rubber to get from the street into the street inlets. Depending on the sewage system, these waters are sometimes not cleaned in the sewage treatment plants and reach the surface waters untreated. To analyse microplastic particles in samples, mainly FTIR or Raman spectroscopic methods are applied at present. Rubber or tire particles in environmental samples cannot be analysed by these methods, because the added carbon black leads to annoying absorption and fluorescent effects. We developed a thermoanalytical method, the so-called TED-GC-MS (thermal extraction desorption gas chromatography mass spectrometry), which allows the simultaneous detection of microplastic and tire wear with almost no sample preparation in about 2.5 h. The TED-GC-MS is a two-step analytical method which consists of a thermobalance and a GC-MS system. Up to 50 mg of an environmental sample is heated up to 600 °C in a nitrogen atmosphere. During pyrolysis, between 300 and 600 °C polymer-specific decomposition products are produced and collected on a solid phase. Afterwards the substances are desorbed, separated and analysed using the GC-MS. The aim of the present work is to present the TED-GC-MS as a time efficient screening method to quantify the industrial most relevant polymers in street run-off samples. Analytical challenges in the determination of polyethylene (PE), polypropylene (PP), polystyrene (PS), polyethylene terephthalate (PET) and polyamide (PA), polymethyl methacrylate (PMMA) and styrene-butadiene-rubber (SBR) as a component of tire wear are honestly discussed. The study area is a 200 m long section of the Clayallee in Berlin, a representative typical urban catchment area. The road run-off in this section flows through the gullies directly into a sample chamber, which directs the runoff in an open channel to the rainwater sewer of this area. The sample chamber allows a sample to be taken directly from the road run-off without mixing with the run-off from other areas. The sample chamber is equipped with an automatic sampler. The automatic sampler is controlled by a conductivity sensor to detect the storm event at an early stage. The sensor gives the sampler a signal to start the sampling program when it gets in contact with water and reaches a certain conductivity threshold. The capacity of the sample container is 100 l and the maximum delivery of the automatic sampler is 2.8 l/min. Afterwards, the water was pumped through various stainless-steel sieves with a diameter of approximately 20 cm and mesh widths of 500, 100, 50 μm. The obtained solids were steam sterilized, freeze-dried and measured with the TED-GC-MS. The results of the TED-GC-MS-measurements are summarized in Figure 1. It shows the polymers which were detected in 1 mg of the dry masses of various street run off samples obtained during a period of 1.5 years. We detected PMMA, PS, PP, PE and SBR, as a component of tire wear in the samples. The quantification of the polymers leads to amounts of PS, PP, PE and SBR between 0 µg and 10 µg. PMMA was only detected in traces. T2 - ICCE 2019 CY - Thessaloniki, Greece DA - 16.06.2019 KW - Microplastics KW - TED-GC-MS KW - Road run-off KW - Chromatography PY - 2019 AN - OPUS4-48301 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -