TY - JOUR A1 - Jiang, C. A1 - Xie, G. A1 - Wu, Dejian A1 - Yan, T. A1 - Chen, S. A1 - Zhao, P. A1 - Wu, Z. A1 - Li, W. T1 - Experimental investigation on an energy-efficient floor heating system with intelligent control: A case study in Chengdu, China N2 - The space heating system accounts for 20%~50% of building energy consumption, and may lead to energy waste due to unreasonable controls. In this study, an energy-efficient floor heating system with intelligent control was proposed to improve energy efficiency of the system. In order to validate the concept of the proposed intelligent control, an experimental system was designed and constructed in Chengdu, China. Temperature, control cycle and energy consumption were then studied under different control strategies. The result shows that a larger flow rate of supply water will result in a longer control cycle and a lower control frequency, i.e., the average control cycle at 7 L min−1 is 1.7 h during the test day, while it is 1.5 h at 5 L min−1. Moreover, adopting water with a higher temperature and flow rate could achieve a higher efficiency of the system. The energy consumptions in case 1 (5 L min−1, 50 °C), case 2 (5 L min−1, 55 °C), case 5 (7 L min−1, 55 °C) and case 6 (7 L min−1, 60 °C) are 4746 kJ, 3534 kJ, 3093 kJ and 3028 kJ, respectively. Based on the experimental data, the supply water temperature is suggested to set lower than 60 °C considering human comfort. KW - Floor heating KW - Intelligent control KW - Experimental KW - Energy consumption KW - Control strategy PY - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:kobv:b43-550522 SN - 2214-157X VL - 26 SP - 1 EP - 14 PB - Elsevier Ltd. AN - OPUS4-55052 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zang, N. A1 - Qian, X. A1 - Shu, C. A1 - Wu, Dejian T1 - Parametric sensitivity analysis for thermal runaway in semi-batch reactors: Application to cyclohexanone peroxide reactions N2 - The semi-batch reactors (SBRs) system, which is widely used in industrial processes, possesses an intrinsic parametric sensitivity, in which infinitesimal disturbances of input parameters can result in large variations in output variables. In this work, local parametric sensitivity analysis (PSA) was used to understand parameter variations and global PSA was conducted to examine the interaction of input parameters. The effects of these parameters on the output of the system model were analyzed based on the Monte Carlo method with Latin hypercube sampling and the extended Fourier amplitude sensitivity test model. The results showed that the evolution of thermal behaviors in SBRs were observed: marginal ignition; thermal runaway; and the quick onset, fair conversion, and smooth temperature profile. The threshold point of transition from marginal ignition to thermal runaway was at the maximal value of local sensitivity, for which the slope with respect to cooling temperature equaled zero. Moreover, the sequence of the global sensitivity of six common input parameters was computed and evaluated. The reliability of the numerical models was verified by using our previous experimental results of cyclohexanone peroxide reaction. This comprehensive sensitivity analysis could provide valuable operating information to improve chemical process safety. KW - Semi-batch reactor KW - Parametric sensitivity analysis KW - Monte Carlo method KW - Thermal runaway KW - Cyclohexanone peroxide PY - 2021 U6 - https://doi.org/10.1016/j.jlp.2021.104436 SN - 0950-4230 VL - 70 SP - 104436 PB - Elsevier Ltd. AN - OPUS4-53659 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Guo, Y. A1 - Ren, K. A1 - Wei, A. A1 - Tao, C. A1 - Huang, W. A1 - Zhao, Peng A1 - Wu, Dejian T1 - Iron dust explosion characteristics with small amount of nano-sized Fe2O3 and Fe3O4 particles N2 - Iron powder, as one of the most abundant metal fuels that can be used as recyclable carriers of clean energy, is a promising alternative to fossil fuels in a future low-carbon economy. It may pose a potential explosion hazard during the process of processing, storage, transport, and reduction/oxidation (redox). The explosion characteristics of iron dust in air were undertaken via a 20 L spherical explosion chamber with an emphasis on minimum explosion concentration (MEC) of iron dust. The alternative method of combustion duration time (tc) was used to determine MEC and compared with the standardized over pressure method. Two kinds of nano-sized iron oxides (Fe2O3 and Fe3O4) were used as inertants to determine the inhibition effect of different oxidation products. The iron dust explosion products with various shapes and sizes were found to be able to grow up 4–6 times of the iron dust for the first time. Adding small amount of Fe2O3 or Fe3O4 could reduce the explosion severity and sensitivity of iron dust. The MEC data determined by both methods were comparable. The addition of 5 % oxide has obvious inhibition effect under 1500 g/m3 concentration. With the increase of oxide concentration to 10 %, the inerting effect increases, and the MEC of iron dust increases more than 3 times. The increase of dust concentration will weaken the inerting effect. When the concentration increases from 500 g/m3 to 3000 g/m3, the weakening effect of 10 % Fe2O3 on the explosion pressure decreases from 38.45 % to 2.24 %, and 10 % Fe3O4 decreases from 46.21 % to 10.63 %. Unlike coal, biomass or aluminum dusts, the iron dust explosion was found to have a unique secondary acceleration of pressure rise rate for the first time. These results provide a fundamental basis to mitigate the iron dust explosion via solid inerting method without adding extra elements. KW - Iron dust KW - Iron oxides KW - MEC KW - Combustion duration time KW - Explosion products KW - Pressure rise rate PY - 2022 U6 - https://doi.org/10.1016/j.fuel.2022.124786 SN - 0016-2361 VL - 324, Part C SP - 1 EP - 13 PB - Elsevier Ltd. AN - OPUS4-55057 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -