TY - JOUR A1 - Wilhelm, Stefan A1 - Kaiser, Martin A1 - Würth, Christian A1 - Heiland, J. A1 - Carrillo-Carrion, C. A1 - Muhr, V. A1 - Wolfbeis, Otto S. A1 - Parak, W.J. A1 - Resch-Genger, Ute A1 - Hirsch, T. T1 - Water dispersible upconverting nanoparticles: effects of surface modification on their luminescence and colloidal stability N2 - We present a systematic study on the effect of surface ligands on the luminescence properties and colloidal stability of β-NaYF4:Yb3+,Er3+ upconversion nanoparticles (UCNPs), comparing nine different surface coatings to render these UCNPs water-dispersible and bioconjugatable. A prerequisite for this study was a large-scale synthetic method that yields ~2 g per batch of monodisperse oleate-capped UCNPs providing identical core particles. These ~23 nm sized UCNPs display an upconversion quantum yield of ~0.35% when dispersed in cyclohexane and excited with a power density of 150 W cm-2, underlining their high quality. A comparison of the colloidal stability and luminescence properties of these UCNPs, subsequently surface modified with ligand exchange or encapsulation protocols, revealed that the ratio of the green (545 nm) and red (658 nm) emission bands determined at a constant excitation power density clearly depends on the surface chemistry. Modifications relying on the deposition of additional (amphiphilic) layer coatings, where the initial oleate coating is retained, show reduced non-radiative quenching by water as compared to UCNPs that are rendered water-dispersible via ligand exchange. Moreover, we could demonstrate that the brightness of the upconversion luminescence of the UCNPs is strongly affected by the type of surface modification, i.e., ligand exchange or encapsulation, yet hardly by the chemical nature of the ligand. KW - upconverting nanoparticles (UCNPs) KW - Luminescence KW - surface modification PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-324071 DO - https://doi.org/10.1039/c4nr05954a SN - 2040-3364 SN - 2040-3372 VL - 7 IS - 4 SP - 1403 EP - 1410 PB - RSC Publ. CY - Cambridge AN - OPUS4-32407 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Busch, C. A1 - Schröter, T. A1 - Grabolle, Markus A1 - Wenzel, M. A1 - Kempe, H. A1 - Kaiser, W.A. A1 - Resch-Genger, Ute A1 - Hilger, I. T1 - An in vivo spectral multiplexing approach for the cooperative imaging of different disease-related biomarkers with near-infrared fluorescent Förster resonance energy transfer probes N2 - In recent years, much progress has been made in analyzing the molecular origin of many diseases in vivo. For most applications, attention has been devoted to the detection of single molecules only. In this study, we present a proof of concept for the straightforward monitoring of interactions between different molecules via Förster resonance energy transfer (FRET) in an in vivo spectral multiplexing approach using conventional small organic dyes covalently attached to antibodies. Methods: We coupled the fluorophores DY-682 (donor; absorption [abs]/emission [em], 674/712 nm), DY-505 (control donor; abs/em, 498/529 nm), and DY-782 (acceptor; abs/em, 752/795 nm) to the model antibody IgG. The occurrence of FRET between these fluorophores was assessed in vitro for conjugate mixtures adsorbed onto membranes, after accumulation into the phagocytic compartment of macrophages (J774 cells), and in vivo in a mouse edema model using a whole-body animal imaging system with multispectral analysis features. Results: When the free acceptor DY-782 was combined with the DY-682 donor, FRET occurred as a consequence of small dye-to-dye distances, unlike the case for mixtures of the dyes DY-782 and DY-505. Our proof of concept was also transferred to living cells after internalization of the DY-682-IgG–DY-782-IgG pair into macrophages and finally to animals, where intermolecular FRET was observed after systemic probe application in vivo in edema-bearing mice. Conclusion: Our simple cooperative-imaging approach enables the noninvasive detection of the presence of two or principally even more neighboring disease-related biomarkers. This finding is of high relevance for the in vivo identification of complex biologic processes requiring strong spatial interrelations of target molecules in key pathologic activation processes such as inflammation, cancer, and neurodegenerative diseases. KW - FRET KW - IgG antibodies KW - In vivo molecular imaging KW - Near-infrared (NIR) fluorophores KW - Multiplexing KW - Cooperative signaling PY - 2012 DO - https://doi.org/10.2967/jnumed.111.094391 SN - 0161-5505 SN - 0097-9058 SN - 0022-3123 SN - 1535-5667 VL - 53 IS - 4 SP - 638 EP - 646 PB - SNM CY - Reston, Va. AN - OPUS4-26069 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schoetz, U. A1 - Deliolanis, N.C. A1 - Ng, D. A1 - Pauli, Jutta A1 - Resch-Genger, Ute A1 - Kühn, E. A1 - Heuer, S. A1 - Beisker, W. A1 - Köster, R.W. A1 - Zitzelsberger, H. A1 - Caldwell, R.B. T1 - Usefulness of a Darwinian system in a biotechnological application: evolution of optical window fluorescent protein variants under selective pressure N2 - With rare exceptions, natural evolution is an extremely slow process. One particularly striking exception in the case of protein evolution is in the natural production of antibodies. Developing B cells activate and diversify their immunoglobulin (Ig) genes by recombination, gene conversion (GC) and somatic hypermutation (SHM). Iterative cycles of hypermutation and selection continue until antibodies of high antigen binding specificity emerge (affinity maturation). The avian B cell line DT40, a cell line which is highly amenable to genetic manipulation and exhibits a high rate of targeted integration, utilizes both GC and SHM. Targeting the DT40's diversification machinery onto transgenes of interest inserted into the Ig loci and coupling selective pressure based on the desired outcome mimics evolution. Here we further demonstrate the usefulness of this platform technology by selectively pressuring a large shift in the spectral properties of the fluorescent protein eqFP615 into the highly stable and advanced optical imaging expediting fluorescent protein Amrose. The method is advantageous as it is time and cost effective and no prior knowledge of the outcome protein's structure is necessary. Amrose was evolved to have high excitation at 633 nm and excitation/emission into the far-red, which is optimal for whole-body and deep tissue imaging as we demonstrate in the zebrafish and mouse model. KW - Fluorescent protein KW - Quantum yield PY - 2014 DO - https://doi.org/10.1371/journal.pone.0107069 SN - 1932-6203 VL - 9 IS - 9 SP - e107069-1 EP - e107069-12 PB - PubMed Central AN - OPUS4-31976 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - DeRose, P.C. A1 - Resch-Genger, Ute T1 - Recommendations for fluorescence instrument qualification: the new ASTM standard guide N2 - Aimed at improving quality assurance and quantitation for modern fluorescence techniques, ASTM International (ASTM) is about to release a Standard Guide for Fluorescence, reviewed here. The guide's main focus is on steady state fluorometry, for which available standards and instrument characterization procedures are discussed along with their purpose, suitability, and general instructions for use. These include the most relevant instrument properties needing qualification, such as linearity and spectral responsivity of the detection system, spectral irradiance reaching the sample, wavelength accuracy, sensitivity or limit of detection for an analyte, and day-to-day performance verification. With proper consideration of method-inherent requirements and limitations, many of these procedures and standards can be adapted to other fluorescence techniques. In addition, procedures for the determination of other relevant fluorometric quantities including fluorescence quantum yields and fluorescence lifetimes are briefly introduced. The guide is a clear and concise reference geared for users of fluorescence instrumentation at all levels of experience and is intended to aid in the ongoing standardization of fluorescence measurements. KW - Fluorescence KW - Method KW - Quantum yield KW - Photoluminescence KW - Standard KW - Emission KW - Spectral correction KW - Excitation KW - Anisotropy KW - Recommendation KW - Instrument qualification PY - 2010 DO - https://doi.org/10.1021/ac902507p SN - 0003-2700 SN - 1520-6882 VL - 82 IS - 5 SP - 2129 EP - 2133 PB - American Chemical Society CY - Washington, DC AN - OPUS4-21066 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Le Guevel, X. A1 - Wegner, Karl David A1 - Würth, Christian A1 - Baulin, V. A. A1 - Musnier, B. A1 - Josserand, V. A1 - Resch-Genger, Ute A1 - Koll, J-C T1 - Tailoring the SWIR emission of gold nanoclusters by surface ligand rigidification and their application in 3D bioimaging N2 - The influence of solvent polarity and surface ligand rigidification on the SWIR emission profile of gold nanoclusters with an anistropic surface was investigated. A strong enhancement of the SWIR emission band at 1200 nm was observed when measuring in different local environments: in solution, in polymer composites, and in solids. SWIR in vivo imaging of mice assisted by deep learning after intravenous administration of these gold nanoclusters provides high definition pseudo-3D views of vascular blood vessels. KW - Nano KW - Nanomaterial KW - Metal cluster KW - Photoluminescence KW - Quantum yield KW - Photophysics KW - Lifetime KW - Sensor KW - NIR KW - SWIR KW - Ligand KW - Gold KW - Mechanism KW - Charge transfer KW - Enhancement strategy KW - Imaging KW - Application KW - Contrast agent PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-543582 DO - https://doi.org/10.1039/D1CC06737K VL - 58 IS - 18 SP - 2967 EP - 2970 PB - RSC AN - OPUS4-54358 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Clark, P.C.J A1 - Andresen, Elina A1 - Sear, M. J. A1 - Favaro, M. A1 - Girardi, L. A1 - van de Krol, R. A1 - Resch-Genger, Ute A1 - Starr, D.E. T1 - Quantification of the Activator and Sensitizer Ion Distributions in NaYF4:Yb3+, Er3+ Upconverting Nanoparticles Via Depth-Profiling with Tender X-Ray Photoemission N2 - The spatial distribution and concentration of lanthanide activator and sensitizer dopant ions are of key importance for the luminescence color and efficiency of upconverting nanoparticles (UCNPs). Quantifying dopant ion distributions and intermixing, and correlating them with synthesis methods require suitable analytical techniques. Here, X-ray photoelectron spectroscopy depth-profiling with tender X-rays (2000–6000 eV), providing probe depths ideally matched to UCNP sizes, is used to measure the depth-dependent concentration ratios of Er3+ to Yb3+, [Er3+]/[Yb3+], in three types of UCNPs prepared using different reagents and synthesis methods. This is combined with data simulations and inductively coupled plasma-optical emission spectroscopy (ICP-OES) measurements of the lanthanide ion concentrations to construct models of the UCNPs’ dopant ion distributions. The UCNP sizes and architectures are chosen to demonstrate the potential of this approach. Core-only UCNPs synthesized with XCl3·6H2O precursors (β-phase) exhibit a homogeneous distribution of lanthanide ions, but a slightly surface-enhanced [Er3+]/[Yb3+] is observed for UCNPs prepared with trifluroacetate precursors (α-phase). Examination of Yb-core@Er-shell UCNPs reveals a co-doped, intermixed region between the single-doped core and shell. The impact of these different dopant ion distributions on the UCNP's optical properties is discussed to highlight their importance for UCNP functionality and the design of efficient UCNPs. KW - Shell KW - Nanomaterial KW - Nano KW - Upconversion nanoparticle KW - Lanthanide KW - Photoluminescence KW - Quantum yield KW - Photophysics KW - Excitation power density KW - Surface KW - Coating KW - Core-shell KW - XPS KW - Intermixing KW - HAXPES KW - Method PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-552075 DO - https://doi.org/10.1002/smll.202107976 SN - 1613-6813 SP - 1 EP - 13 PB - Wiley-VCH-Verlag CY - Weinheim, Germany AN - OPUS4-55207 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gers-Panther, C.F. A1 - Fischer, H. A1 - Nordmann, J. A1 - Seiler, T. A1 - Behnke, Thomas A1 - Würth, Christian A1 - Frank, W. A1 - Resch-Genger, Ute A1 - Müller, T.J.J. T1 - Four- and Five-Component Syntheses and Photophysical Properties of Emission Solvatochromic 3‑Aminovinylquinoxalines N2 - 3-Aminovinylquinoxalines are readily accessible from (hetero)aryl glyoxylic acids or heterocyclic π-nucleophiles by consecutive four- and fivecomponent syntheses in the sense of an activation-alkynylation-cyclocondensation-addition sequence or glyoxylation-alkynylation-cyclocondensation-addition sequence in good yields. The title compounds are highly fluorescent with pronounced emission solvatochromicity and protochromic fluorescence quenching. Time-resolved fluorescence spectroscopy furnishes radiative and nonradiative fluorescence decay rates in various solvent polarities. The electronic structure is corroborated by DFT and TD-DFT calculations rationalizing the observed spectroscopic effects. KW - Dye KW - Syntheseis KW - Spectroscopy PY - 2016 DO - https://doi.org/10.1021/acs.joc.6b02581 SN - 0022-3263 VL - 82 SP - 567 EP - 578 PB - ACS Publications AN - OPUS4-39211 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - DeRose, P.C. A1 - Wang, L. A1 - Gaigalas, A.K. A1 - Kramer, G.W. A1 - Resch-Genger, Ute A1 - Panne, Ulrich ED - Resch-Genger, Ute ED - O.S. Wolfbeis, T1 - Need for and metrological approaches towards standardization of fluorescence measurements from the view of national metrology institutes N2 - The need for standardization in fluorescence measurements to improve quality assurance and to meet regulatory demands is addressed from the viewpoint of National Metrology Institutes (NMIs). Classes of fluorescence standards are defined, including instrument calibration standards for the determination and correction of instrument bias, application-specific standards based on commonly used fluorescent labels, and instrument validation standards for periodic checks of instrument performance. The need for each class of standard is addressed and on-going efforts by NMIs and others are described. Several certified reference materials (CRMs) that have recently been developed by NMIs are highlighted. These include spectral correction standards, developed independently by both NIST and BAM (Germany), and fluorescence intensity standards for flow cytometry, developed by NIST. In addition, future activities at both institutes are addressed such as the development of day-to-day intensity standards. KW - Fluorescence spectroscopy KW - Quality assurance KW - Calibration KW - Standard KW - Comparability KW - Quantification KW - Traceability KW - Radiometry KW - Emission standard KW - Fluorescent glass KW - Spectral correction KW - Spectral fluorescence standard PY - 2008 SN - 978-3-540-75206-6 DO - https://doi.org/10.1007/4243_2008_049 SN - 1617-1306 N1 - Serientitel: Springer Series on Fluorescence – Series title: Springer Series on Fluorescence VL - 5 IS - Part A SP - 33 EP - 62 PB - Springer AN - OPUS4-18996 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Resch-Genger, Ute A1 - DeRose, P.C. T1 - Fluorescence standards: Classification, terminology, and recommendations on their selection, use, and production (IUPAC Technical Report) N2 - Chromophore-based fluorescence standards for the characterization of photo-luminescence measuring systems and the determination of relevant fluorometric quantities are classified according to their scope and area of application. General and type-specific requirements for suitable standards are derived for each class of standards. Metrological requirements linked to the realization of comparable measurements are addressed and recommendations on selecting, using, and developing fluorescence standards are given. KW - Chromophore-based fluorescence standards KW - Fluorometric quantities KW - IUPAC analytical chemistry division KW - IUPAC organic and biomolecular chemistry division KW - IUPAC physical and biophysical chemistry division KW - Photoluminescence KW - Standards PY - 2010 DO - https://doi.org/10.1351/PAC-REP-09-09-02 SN - 0033-4545 SN - 1365-3075 VL - 82 IS - 12 SP - 2315 EP - 2335 PB - Union CY - Research Triangle Park, NC AN - OPUS4-22693 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Resch-Genger, Ute A1 - DeRose, P.C. T1 - Characterization of photoluminescence measuring systems (IUPAC technical report) N2 - Procedures for the characterization of photoluminescence measuring systems are discussed, focusing on spectrofluorometers and fit-for-purpose methods including suitable standards. The aim here is to increase the awareness for the importance of a reliable instrument characterization and to improve the reliability and comparability of measurements of photoluminescence. KW - Fluorescence intensities KW - Instrument calibration KW - IUPAC Analytical Chemistry Division KW - IUPAC organic and biomolecular chemistry division KW - IUPAC physical and biophysical chemistry division KW - Performance validation KW - Photoluminescence KW - Photoluminescence measuring systems KW - Relative fluorescence quantum yields KW - Fluorescence standard KW - Quality assurance KW - Instrument qualification PY - 2012 DO - https://doi.org/10.1351/PAC-REP-10-07-07 SN - 0033-4545 SN - 1365-3075 VL - 84 IS - 8 SP - 1815 EP - 1835 PB - Union CY - Research Triangle Park, NC AN - OPUS4-26283 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Radnik, Jörg A1 - Knigge, Xenia A1 - Andresen, Elina A1 - Resch-Genger, Ute A1 - Cant, D.J.H. A1 - Shard, A.G. A1 - Clifford, C.A. T1 - Composition, thickness, and homogeneity of the coating of core–shell nanoparticles—possibilities, limits, and challenges of X-ray photoelectron spectroscopy N2 - Core–shell nanoparticles have attracted much attention in recent years due to their unique properties and their increasing importance in many technological and consumer products. However, the chemistry of nanoparticles is still rarely investigated in comparison to their size and morphology. In this review, the possibilities, limits, and challenges of X-ray photoelectron spectroscopy (XPS) for obtaining more insights into the composition, thickness, and homogeneity of nanoparticle coatings are discussed with four examples: CdSe/CdS quantum dots with a thick coating and a small core; NaYF4-based upconverting nanoparticles with a large Yb-doped core and a thin Er-doped coating; and two types of polymer nanoparticles with a poly(tetrafluoroethylene) core with either a poly(methyl methacrylate) or polystyrene coating. Different approaches for calculating the thickness of the coating are presented, like a simple numerical modelling or a more complex simulation of the photoelectron peaks. Additionally, modelling of the XPS background for the investigation of coating is discussed. Furthermore, the new possibilities to measure with varying excitation energies or with hard-energy X-ray sources (hard-energy X-ray photoelectron spectroscopy) are described. A discussion about the sources of uncertainty for the determination of the thickness of the coating completes this review. KW - X-ray spectroscopy KW - Nanoparticles KW - Spectroscopy / Instrumentation KW - Spectroscopy / Theory PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-548305 DO - https://doi.org/10.1007/s00216-022-04057-9 VL - 414 IS - 15 SP - 4331 EP - 4345 PB - SpringerNature AN - OPUS4-54830 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -