TY - GEN A1 - Boehm, U. A1 - Nelson, G. A1 - Brown, C. M. A1 - Bagley, S. A1 - Bajcsy, P. A1 - Bischof, J. A1 - Dauphin, A. A1 - Dobbie, I. M. A1 - Eriksson, J. E. A1 - Faklaris, O. A1 - Fernandez-Rodriguez, J. A1 - Ferrand, A. A1 - Gelman, L. A1 - Gheisari, A. A1 - Hartmann, H. A1 - Kukat, C. A1 - Laude, A. A1 - Mitkovski, M. A1 - Munck, S. A1 - North, A. J. A1 - Rasse, T. M. A1 - Resch-Genger, Ute A1 - Schuetz, L. C. A1 - Seitz, A. A1 - Strambio-De-Castillia, C. A1 - Swedlow, J. R. A1 - Nitschke, R. T1 - Author correction: QUAREP-LiMi: a community endeavor to advance quality assessment and reproducibility in light microscopy N2 - This is a corrigendum to the original article "QUAREP-LiMi: a community endeavor to advance quality assessment and reproducibility in light microscopy" that was published in the journal "Nature methods", vol. 18 (2021), pp. 1424-1427. PY - 2022 DO - https://doi.org/10.1038/s41592-021-01387-x SN - 1548-7105 SP - 1 PB - Nature Publishing Group CY - London AN - OPUS4-54270 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute A1 - Wegner, Karl David A1 - Kalot, G. A1 - Busser, B. A1 - Pliquett, J. A1 - Köster, U. A1 - Koll, J. C. A1 - Denat, F. A1 - Bodio, E. A1 - Goze, C. A1 - Sacey, L. T1 - NIR aza-BODIPY: a new vector for boron neutron capture therapy (BNCT) N2 - Boron neutron capture therapy (BNCT) relies on the activation of 10B by thermal neutrons, which results in small highly energetic particle emission inducing cancer cells damage. However, in order to overcome the limits of the currently used BNCT agents, it is necessary to design new systems, which can specifically accumulate and deliver a sufficient amount of 10B in tumors. In this study, we designed a 10B-BSH-containing aza-BODIPY (aza-SWIR-BSH). It enabled the efficient vectorization of clinically used 10B-BSH to the tumor, resulting in higher therapeutic activity than the 10B-BSH alone. T2 - EMIM 2021 CY - Göttingen, Germany DA - 24.08.2021 KW - Flourescence KW - Optical probe KW - Dye KW - Photophysics KW - Quantum yield KW - Mechanism KW - NIR KW - SWIR KW - Imaging KW - Method KW - Quality assurance KW - BODIPY KW - Boron Neutron Capture Therapy (BNCT) KW - Medicine KW - Life sciences PY - 2021 AN - OPUS4-53731 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Resch-Genger, Ute A1 - Wang, Cui A1 - You, Y. A1 - Förster, C. A1 - Schubert, H. A1 - Heinze, K. A1 - Seitz, M. T1 - NIR-NIR-Aufkonvertierung in molekularen Chrom-Ytterbium-Salzen N2 - Photonen-Aufkonvertierung in hetero-oligonuklearen, Metallkomplex-Architekturen mit organischen Liganden ist ein interessantes, aber bisher selten beobachtetes Phänomen, trotz des großen Potentials sowohl aus Sicht der Grundlagenforschung als auch aus der Anwendungsperspektive. Nun wurde ein neues photonisches Material aus molekularen Chrom(III)- und Ytterbium(III)-Komplexionen entwickelt. Dieses zeigt im Festkörper bei Raumtemperatur abhängig von der Anregungsleistungsdichte nach Anregung des 2F7/2! 2F5/2-3berganges des Ytterbiums bei ca. 980 nm eine kooperative Sensibilisierung der Chrom(III)-zentrierten 2E/2T1-Phosphoreszenz bei ca. 775 nm. Der Aufkonvertierungsprozess ist unempfindlich gegenüber Luftsauerstoff und kann in Gegenwart von Wassermolekülen im Kristallgitter beobachtet werden. KW - Crystal KW - Sensor KW - NIR KW - Yb(III) complex KW - Cr(III) KW - Upconversion PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-517217 DO - https://doi.org/10.1002/ange.202007200 VL - 132 IS - 42 SP - 18804 EP - 18808 PB - Angewandte Chemie AN - OPUS4-51721 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Resch-Genger, Ute A1 - Fallisch, A. A1 - Petrov, E. P. A1 - Salhany, R. A1 - Forthman, C. A1 - Guttenberg, Z. A1 - Nitschke, R. T1 - Spectral fluorescence standards for the calibration and performance validation of fluorescence microscopes N2 - The standardization and calibration of fluorescence microscopy have become increasingly vital due to the wide-spread use of in life and materials sciences. As the demand for reliable and user-friendly methods to assess micro-scope performance grows, universal calibration tools accessible to both researchers and vendors are needed. To support the standardization of characterization methods in microscopy, it is crucial to provide calibration tools together with standardized operating procedures for their effective implementation. The public-funded project "FluMiKal"* develops calibration tools in the shape of typical microscopic slides to assess key parameters such as spatial resolution, point spread function, spectral sensitivity, linearity and sensitivity of the detection system. The focus is on creating calibration tools that are user-friendly, robust, and versatile in their application. This work addresses the critical parameter of wavelength-dependent spectral sensitivity, which affects the meas-ured signals from the instrument side, yielding instrument-specific data and instrument aging-induced changes over time. For this purpose, μ-slides from ibidi with six channels are used, allowing them to be filled with different solutions containing molecular or nanoscale fluorophores with well-characterized absorption and fluorescence properties. The certified spectral fluorescence standards BAM-F003, F004, F005, and F007 assessed provided as ethanolic solutions by the Federal Institute for Materials Research and Testing (BAM), cover a broad spectral range from the blue to the near-infrared [1], [2]. Dye-based slide prototypes have been used to determine the spectral sensitivity of confocal microscopes from different vendors with various detector types by acquiring the spectral data of the BAM dyes under standardized measurement conditions, demonstrating the applicability of this concept. Proof-of-concept experiments could demonstrate the proper sealing of the slides. Further experiments will explore long-term stability and their potential as standards for relative intensity calibrations. * FluMiKal is funded by the Federal Ministry for Economic Affairs and Climate Action, Germany (WIPANO FKZ 03TN0047B) [1] doi: 10.1007/4243_2008_028. [2] doi: 10.1007/s00216-024-05723-w. T2 - European Light Microscopy Initiative - ELMI 2025 CY - Heidelberg, Germany DA - 03.06.2025 KW - Fluorescence KW - Advanced material KW - Validation KW - Calibration KW - Method comparison KW - Reference material KW - Dye KW - Fluorescence standard KW - Microscopy KW - CLSM KW - Imaging PY - 2025 AN - OPUS4-64206 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Koshkina, Olga A1 - Bantz, C. A1 - Würth, Christian A1 - Lang, Thomas A1 - Resch-Genger, Ute A1 - Maskos, Michael T1 - Fluorophore-labeled siloxane-based nanoparticles for biomedical applications N2 - We present the synthesis and characterization of multifunctional fluorophore-labeled poly(organosiloxane) nanoparticles with core-shell architecture, where the fluorescent dye is incorporated into the core. Grafting of heterobifunctional poly(ethylene oxide) (PEO) onto the particle surface leads to water-soluble biocompatible nanoparticles. Two different strategies have been used for the synthesis: The encapsulation of dye-labeled monomers during the polycondensation with additional PEO coating and subsequent dye labeling by covalent attachment of the fluorescent dye rhodamine B to the (chloromethylphenyl)siloxane groups in the core after polymerization and grafting of PEO onto the surface. Comparison of the fluorescence quantum yields of the nanoparticles before and after PEO coating show a decrease in quantum yield after PEO coating. KW - Biocompatibility KW - Core-shell KW - Fluorescence KW - Fluorescence quantum yield KW - Nanoparticles KW - PEO PY - 2011 DO - https://doi.org/10.1002/masy.201100041 SN - 1022-1360 SN - 0258-0322 SN - 1521-3900 VL - 309/310 IS - 1 SP - 141 EP - 146 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-25143 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Engel, A. A1 - Ottermann, C. A1 - Resch-Genger, Ute A1 - Hoffmann, Katrin A1 - Schweizer, S. A1 - Selling, J. A1 - Spaeth, J.-M. A1 - Rupertus, V. ED - Grzymala, R. ED - Haeberlé, O. T1 - Glass based fluorescence reference materials used for optical and biophotonic applications N2 - Fluorescence techniques are known for their high sensitivity and are widely used as analytical tools and detection methods for product and process control, material sciences, environmental and biotechnical analysis, molecular genetics, cell biology, medical diagnostics, and drug screening. For routine measurements by fluorescence techniques the existence of an improved quality assurance is one of the basic needs. According to DIN/ISO 17025 certified standards are used for fluorescence diagnostics having the drawback of giving relative values only. Typical requirements onto fluorescence reference materials or standards deal with the verification of the instrument performance as well as the improvement of the data comparability. Especially for biomedical applications fluorescence labels are used for the detection of proteins. In particular these labels consist of nano crystalline materials like CdS and CdSe. The field of Non-Cadmium containing materials is under investigation. In order to evaluate whether glass based materials can be used as standards it is necessary to calculate absolute values like absorption/excitation cross sections or relative quantum yields. This can be done using different quantities of dopands in glass, glass ceramics or crystals. The investigated materials are based on different types of glass, silicate, phosphate and boron glass, which play a dominant role for the absorption and emission mechanism. Additional to the so-called elementary fluorescence properties induced by raw earth elements the formation of defects lead to higher cross sections additionally. The main investigations deal with wavelength accuracy and lifetime of doped glasses, glass ceramics and crystalline samples. Moreover intensity patterns, homogeneity aspects and photo stability will be discussed. KW - Fluorescence KW - Reference material KW - Glass KW - Glass ceramics KW - Biophotonic KW - Multiplexing PY - 2006 DO - https://doi.org/10.1117/12.663627 SN - 1605-7422 VL - 6191 SP - 619110-1-619110-10 AN - OPUS4-14429 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Saleh, Maysoon I. A1 - Kembuan, C A1 - Rühle, Bastian A1 - Graf, C A1 - Resch-Genger, Ute T1 - Gold-shell coated NaYF4:Er3+, Yb3+ nanoparticles for the enhancement of fluorescence emission N2 - In the present work, we aim to explore how far the UCNP emission intensity can be enhanced by the aid of plasmonic interactions using a gold shell. The distance between the UCNP core and the gold shell is varied by adding a silica spacer of different thicknesses. The synthetic conditions for obtaining UCNP@SiO2@Au core-shell nanoparticles with precisely tuneable silica shell thicknesses were investigated. A gold shell on the UCNP@SiO2 nanoparticles is expected to give rise to a noticeable enhancement of particle brightness and fluorescence, given that the thicknesses of the silica shell and the gold coating can be controlled and fine-tuned. First single particle studies revealing shortening of the Er3+ lifetimes suggest that plasmonic enhancement occurs. T2 - 2nd Conference and Spring School on Properties, Design and Applications of Upconversion Nanomaterials CY - Valencia, Spain DA - 02.04.2018 KW - Upconversion nanoparticles KW - Silica coating KW - Plasmonic enhancement PY - 2018 AN - OPUS4-44969 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rühle, Bastian A1 - Resch-Genger, Ute A1 - Kembuan, C A1 - Graf, C T1 - Gold-shell coated NaYF4:Er3+, Yb3+ nanoparticles for the enhancement of fluorescence emission N2 - In the present work, we aim to explore how far the UCNP emission intensity can be enhanced by the aid of plasmonic interactions using a gold shell. The distance between the UCNP core and the gold shell is varied by adding a silica spacer of different thicknesses. The synthetic conditions for obtaining UCNP@SiO2@Au core-shell nanoparticles with precisely tuneable silica shell thicknesses were investigated. A gold shell on the UCNP@SiO2 nanoparticles is expected to give rise to a noticeable enhancement of particle brightness and fluorescence, given that the thicknesses of the silica shell and the gold coating can be controlled and fine-tuned. First single particle studies revealing shortening of the Er3+ lifetimes suggest that plasmonic enhancement occurs. T2 - 2nd Conference and Spring School on Properties, Design and Applications of Upconversion Nanomaterials CY - Valencia, Spain DA - 02.04.2018 KW - Upconversion nanoparticles KW - Silica coating KW - Plasmonic enhancement PY - 2018 AN - OPUS4-44958 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Engel, A. A1 - Ottermann, C. A1 - Klahn, J. A1 - Korb, T. A1 - Resch-Genger, Ute A1 - Hoffmann, Katrin A1 - Kynast, U. A1 - Rupertus, V. ED - Dan V. Nicolau, ED - Daniel L. Farkas, ED - Robert C. Leif, T1 - Anorganic fluorescence reference materials for decay time of fluorescence emission N2 - Fluorescence techniques are known for their high sensitivity and are widely used as analytical tools, detection methods and imaging applications for product and process control, material sciences, environmental and bio-technical analysis, molecular genetics, cell biology, medical diagnostics, and drug screening. According to DIN/ISO 17025 certified standards are used for steady state fluorescence diagnostics, a method having the drawback of giving relative values for fluorescence intensities only. Therefore reference materials for a quantitative characterization have to be related directly to the materials under investigation. In order to evaluate these figures it is necessary to calculate absolute numbers such as absorption/excitation cross sections and quantum yield. This has been done for different types of dopands in different materials such as glass, glass ceramics, crystals or nano crystalline material embedded in polymer matrices. Samples doped with several fluophores of different emission wavelengths and decay times are required for fluorescent multiplexing applications. Decay times shorter than 100 ns are of special interest. In addition, a proper knowledge is necessary of quantum efficiency in highly scattering media. Recently, quantum efficiency in YAG:Ce glass ceramics has been successfully investigated. Glass and glass ceramics doped with threefold charged rare earth elements are available. However, these samples have the disadvantage of emission decay times much longer than 1 microsecond, due to the excitation and emission of their optical forbidden electronic transitions. Therefore first attempts have been made to produce decay-time standards based on organic and inorganic fluophores. Stable LUMOGEN RED pigments and YAG:Ce phosphors are diluted simultaneously in silicone matrices using a wide range of concentrations between 0.0001 and 2 wt%. Organic LUMOGEN RED has decay times in the lower nanosecond range with a slight dependency on concentration and temperature. In addition, the well-known decay properties of inorganic YAG:Ce are observed also embedded in silicone matrix. Luminescent silicone layers are obtained with thicknesses between 150 and 300 m and no change of decay time, which has been determined to be between 60 and 62 ns. Finally, first results are shown for fluorescent CaF2:Pb glass ceramics embedded in a silicate glass matrix. Wavelength accuracy and lifetime are characterized for different environmental conditions such as temperature treatment and UV irradiation. Moreover, intensity patterns, e.g. line profiles and results, are discussed on homogeneity and photo and thermal stability, respectively. Fluorescence (steady state, decay time) and absorption (remission, absorption) spectroscopy are employed as diagnostic methods to get a microscopic view of the relevant physical processes. The work is funded by BMBF under project number 13N8849. KW - Fluorescence KW - Reference material KW - Glass KW - Glass ceramic KW - Phosphor KW - Doped glass and glass ceramics PY - 2008 SN - 978-0-8194-7034-8 DO - https://doi.org/10.1117/12.767633 VL - 6859 SP - 68591A-1 - 68591A-10 PB - SPIE, the International Society for Optical Engineering CY - Bellingham, Wash. AN - OPUS4-19800 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Resch-Genger, Ute A1 - Pfeifer, Dietmar A1 - Hoffmann, Katrin A1 - Flachenecker, Günter A1 - Hoffmann, Angelika A1 - Monte, C. ED - Resch-Genger, Ute ED - O.S. Wolfbeis, T1 - Linking fluorometry to radiometry with physical and chemical transfer standards: instrument characterization and traceable fluorescence measurements N2 - Problems associated with the measurement of photoluminescence are briefly reviewed, including relevant instrument parameters affecting these measurements. Procedures for the characterization of relevant instruments are discussed, focusing on spectrofluorometers, and fit-for-purpose methods including suitable standards are recommended. The aim here is to increase the awareness of the importance of reliable instrument characterization and to improve the comparability of measurements of photoluminescence. KW - Calibration KW - Emission standards KW - Fluorescence intensity standards KW - Fluorescence standards KW - Quality assurance KW - Spectral correction PY - 2008 SN - 978-3-540-75206-6 DO - https://doi.org/10.1007/4243_2008_054 SN - 1617-1306 N1 - Serientitel: Springer Series on Fluorescence – Series title: Springer Series on Fluorescence VL - 5 IS - Part II SP - 65 EP - 99 PB - Springer AN - OPUS4-18301 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Homann, C. A1 - Krukewitt, Lisa A1 - Frenzel, Florian A1 - Grauel, Bettina A1 - Würth, Christian A1 - Resch-Genger, Ute A1 - Haase, M. T1 - Aufwärtskonvertierende NaYF4:Yb,Er/NaYF4‐Kern/Schale‐Nanokristalle mit hoher Lumineszenzquantenausbeute N2 - Eine modifizierte Syntheseroute auf der Basis wasserfreier Seltenerdacetate wurde zur Synthese aufwärtskonvertierender Kern/Schale‐Nanokristalle mit mittleren Größen zwischen 15 bis 45 nm eingesetzt. Die nahezu monodispersen Partikel bestehen aus einem NaYF4:Yb,Er‐Kern, dotiert mit 18 % Yb3+ und 2 % Er3+, und einer inerten Schale aus NaYF4, wobei die Dicke der Schale dem jeweiligen Radius des Kernpartikels entspricht. Absolutmessungen der Photolumineszenz‐Quantenausbeuten bei verschiedenen Anregungsleistungsdichten zeigen, dass die Quantenausbeuten von 45 nm Kern/Schale‐Partikeln schon fast an die Quantenausbeute des mikrokristallinen aufwärtskonvertierenden Leuchtstoffs heranreichen. Kleinere Kern/Schale‐Partikel, die nach der gleichen Methode hergestellt wurden, zeigen nur eine moderate Abnahme der Quantenausbeute. Beispielsweise ist die Quantenausbeute von 15 nm großen Kern/Schale‐Partikeln bei hohen Leistungsdichten (100 W cm−2) nur um einen Faktor drei kleiner als die des mikrokristallinen Leuchtstoffpulvers und um ungefähr einen Faktor 10 kleiner bei niedrigen Leistungsdichten (1 W cm−2). KW - Nicht lineare Prozesse KW - Nanopartikel KW - Quantenausbeute PY - 2018 DO - https://doi.org/10.1002/ange.201803083 VL - 130 IS - 28 SP - 8901 EP - 8905 PB - Wiley VCH Verlag AN - OPUS4-45573 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Engel, A. A1 - Ottermann, C. A1 - Klahn, J. A1 - Enseling, D. A1 - Korb, T. A1 - Resch-Genger, Ute A1 - Hoffmann, Katrin A1 - Schweizer, S. A1 - Selling, J. A1 - Kynast, U. A1 - Koberling, F. A1 - Rupertus, V. T1 - Fluorescence reference materials used for optical and biophotonic applications N2 - Fluorescence techniques are known for their high sensitivity and are widely used as analytical tools and detection methods for product and process control, material sciences, environmental and bio-technical analysis, molecular genetics, cell biology, medical diagnostics, and drug screening. According to DIN/ISO 17025 certified standards are used for fluorescence diagnostics having the drawback of giving relative values for fluorescence intensities only. Therefore reference materials for a quantitative characterization have to be related directly to the materials under investigation. In order to evaluate these figures it is necessary to calculate absolute numbers like absorption/excitation cross sections and quantum yield. This can be done for different types of dopands in different materials like glass, glass ceramics, crystals or nano crystalline material embedded in polymer matrices. Based on the optical spectroscopy data we will discuss options for characteristic doped glasses and glass ceramics with respect to scattering and absorption regime. It has shown recently for YAG:Ce glass ceramics that for a proper determination of the quantum efficiency in these highly scattering media a reference material with similar scattering and fluorescent properties is required. This may be performed using the emission decay measurement diagnostics, where the decay time is below 100 ns. In this paper we present first results of these aspects using well performing LUMOGEN RED organic pigments for a comparison of mainly transparent glass with glass ceramics doped with various amounts of dopands e.g. ions of raw earth elements and transition metals. The LUMOGEN red is embedded in silica and polyurethane matrices. Characterisations on wavelength accuracy and lifetime for different environmental conditions (temperature, UV irradiation) have been performed. Moreover intensity patterns and results for homogeneity, isotropy, photo and thermal stability will be discussed. In a next step we will show the transfer of the characterisation methods to inorganic fluophores (YAG:Ce) in silicon. Fluorescence (steady state, decay time) and absorption (remission, absorption) spectroscopy working in different temperature regimes (10 - 350 K) are employed diagnostic methods in order to get a microscopic view of the relevant physical processes and to prove the correctness of the obtained data. The work is funded by BMBF under project number 13N8849. KW - Fluorescence KW - Reference material KW - Glass KW - Glass ceramic KW - Phosphor KW - Doped glass KW - Glass ceramics PY - 2007 SN - 0-8194-6247-0 DO - https://doi.org/10.1117/12.728144 SN - 1605-7422 VL - 6628 SP - 662815-1 - 662815-9 AN - OPUS4-16729 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - López de Ipina, J.-M. A1 - Arevalillo, A. A1 - Martín, A. A1 - Caillard, B. A1 - Marcoulaki, E. A1 - Aguerre- Charol, O. A1 - van Duuren-Stuurman, B. A1 - Hodoroaba, Vasile-Dan A1 - Viitanen, A.-K. A1 - Witters, H. A1 - Vercauteren, S. A1 - Persson, K. A1 - Bard, D. A1 - Evans, G. A1 - Jensen, K.A. A1 - Himly, M. A1 - Scalbi, S. A1 - Papin, A. A1 - Le Bihan, O. A1 - Kanerva, T. A1 - Tirez, K. A1 - Frijns, E. A1 - Niga, P. A1 - Eleftheriadis, K. A1 - Travlos, A. A1 - Geppert, M. A1 - Himly, M. A1 - Radnik, Jörg A1 - Kuchenbecker, Petra A1 - Resch-Genger, Ute A1 - Fraboulet, I. A1 - Bressot, C. A1 - Rissler, J. A1 - Gaucher, R. A1 - Binotto, G. A1 - Krietsch, Arne A1 - Braun, A. A1 - Abenet, S. A1 - Catalan, J. A1 - Verstraelen, S. A1 - Manier, N. A1 - Manzo, S. A1 - Fransman, S. A1 - Queron, J. A1 - Charpentier, D. A1 - Taxell, D. A1 - Säämänen, A. A1 - Brignon, J.-M. A1 - Jovanovic, A. A1 - Bisson, M A1 - Neofytou, P. T1 - EC4Safenano - Catalogue of Services N2 - The publicly available document encapsulates the first version of the Catalogue of Services of the future EC4Safenano Centre (CoS 2019). The CoS 2019 is structured in 12 Service Categories and 27 Service Topics, for each of the 12 categories considered. This architecture configures a 12 x 27 matrix that allows ordering the potential EC4Safenano offer in 324 types of services/groups of services. Each type of service/group of services is described, in a simple and friendly way, by means of a specific service sheet: the EC4Safenano - Service Data Sheet (EC4-SDS). These EC4-SDSs allow structuring and summarizing the information of each service, providing the customer with a concise view of characteristics of the service and also the contact details with the service provider. The CoS 2019 deploys a map of services consisting of a set of 100 EC4-SDSs, covering 7 of the 12 Service Categories and 17 of the 27 Service Topics. The harmonization of services is visualized as a future necessary step in EC4Safenano, in order to strengthen the offer and provide added value to customers with a growing offer of harmonized services in future versions of the CoS. The information contained in this document is structured in 3 main sections, as follows: • Catalogue structure. This section describes in short the main characteristics of the CoS 2019. • Catalogue content. This section represents the core part of the document and encapsulates the set of 100 SDSs displaying the offer proposed by the CoS 2019. • Online Catalogue. This section describes the resources implemented by EC4Safenano to facilitate the on-line consultation of the CoS 2019 by customers and other interested parties. KW - Nano-safety KW - Analytical services KW - Nanomaterials KW - Catalogue of services KW - EC4SafeNano KW - European Centre PY - 2021 UR - https://ec4safenano.eu-vri.eu/Public/Guidance SP - 1 EP - 72 PB - EU-VRi – European Virtual Institute for Integrated Risk Management CY - Stuttgart, Germany AN - OPUS4-52943 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - DeRose, P.C. A1 - Wang, L. A1 - Gaigalas, A.K. A1 - Kramer, G.W. A1 - Resch-Genger, Ute A1 - Panne, Ulrich ED - Resch-Genger, Ute ED - O.S. Wolfbeis, T1 - Need for and metrological approaches towards standardization of fluorescence measurements from the view of national metrology institutes N2 - The need for standardization in fluorescence measurements to improve quality assurance and to meet regulatory demands is addressed from the viewpoint of National Metrology Institutes (NMIs). Classes of fluorescence standards are defined, including instrument calibration standards for the determination and correction of instrument bias, application-specific standards based on commonly used fluorescent labels, and instrument validation standards for periodic checks of instrument performance. The need for each class of standard is addressed and on-going efforts by NMIs and others are described. Several certified reference materials (CRMs) that have recently been developed by NMIs are highlighted. These include spectral correction standards, developed independently by both NIST and BAM (Germany), and fluorescence intensity standards for flow cytometry, developed by NIST. In addition, future activities at both institutes are addressed such as the development of day-to-day intensity standards. KW - Fluorescence spectroscopy KW - Quality assurance KW - Calibration KW - Standard KW - Comparability KW - Quantification KW - Traceability KW - Radiometry KW - Emission standard KW - Fluorescent glass KW - Spectral correction KW - Spectral fluorescence standard PY - 2008 SN - 978-3-540-75206-6 DO - https://doi.org/10.1007/4243_2008_049 SN - 1617-1306 N1 - Serientitel: Springer Series on Fluorescence – Series title: Springer Series on Fluorescence VL - 5 IS - Part A SP - 33 EP - 62 PB - Springer AN - OPUS4-18996 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -