TY - GEN A1 - Krause, Martin A1 - Gräfe, Boris A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Streicher, Doreen ED - Christian U. Grosse, T1 - New possibilities for ultrasonic imaging of concrete elements KW - Beton KW - Zerstörungsfreie Prüfung im Bauwesen (ZfPBau) KW - Ultraschallecho-Verfahren KW - Luftgekoppelter Ultraschall KW - Phased array PY - 2007 SN - 978-3-540-72447-6 SP - 575 EP - 582 PB - Springer CY - Heidelberg AN - OPUS4-19107 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krause, Martin A1 - Gräfe, Boris A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Friese, Martin A1 - Wiggenhauser, Herbert A1 - Mayer, K. ED - M.G. Alexander, ED - H.-D. Beushausen, ED - F. Dehn, ED - P. Moyo, T1 - Ultrasonic imaging of post-tensioned concrete elements: New techniques for reliable localization of grouting defects T2 - 2nd International Conference on Concrete Repair, Rehabilitation and Retrofitting CY - Cape Town, South Africa DA - 2008-11-24 KW - Post-tensioned concrete KW - Ultrasonic echo KW - Phase evaluation KW - Air-coupled ultrasound PY - 2009 SN - 978-0-415-46850-3 SP - 521 EP - 527 PB - CRC Press CY - Boca Raton AN - OPUS4-20651 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wiggenhauser, Herbert A1 - Krause, Martin A1 - Maierhofer, Christiane A1 - Algernon, Daniel A1 - Gardei, André A1 - Gräfe, Boris A1 - Kohl, Christoph A1 - Lausch, Regine A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Streicher, Doreen A1 - Zacher, Gerhard T1 - Grundlagen kombinierter zerstörungsfreier Prüfverfahren zur Untersuchung von Betonbauteilen T2 - Forschergruppe 384 Abschlusskolloquium CY - Bergisch Gladbach, Deutschland DA - 2007-05-03 PY - 2007 SP - 23 EP - 44 PB - BAM CY - Berlin AN - OPUS4-14805 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Krause, Martin A1 - Wiggenhauser, Herbert T1 - Praxiseinsatz eines Ultraschall-Verfahrens zur Strukturuntersuchung von Betonbauteilen N2 - Einsatzbereiche des Meßsystems: - Ortung von Strukturelementen oder Verdichtungsmängeln in Beton - Dickenbestimmung von Bauteilen bei einseitiger Zugänglichkeit - Messung des Haftverbundes bei mehrschichtigen Bauteilen Auswerteverfahren: - Prinzip der laufzeitkorrigierten Überlagerung Vorteile: - Automatischer Meßablauf durch Array-Technik - Flexibler Einsatz durch lange Kabelverbindungen zwischen Prüfkopfarray und Meßapparatur T2 - Fachtagung Bauwerksdiagnose - Praktische Anwendungen Zerstörungsfreier Prüfungen CY - Munich, Germany DA - 21.01.1999 KW - Dickenmessung KW - Sohlplatte KW - Leerrohre PY - 1999 AN - OPUS4-36521 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Helmerich, Rosemarie A1 - Milmann, Boris A1 - Wöstmann, Jens T1 - Bond durability of CFRP-laminates on concrete bridges N2 - Trans-European corridors for transport of people and goods require strengthening of bridges to carry increased axle loads in terms of absolute axle loads and of their frequency. Most of the bridges along highways are reinforced or prestressed concrete bridges. Since the late 1990s, CFRP laminates have been applied to box girder and T-beam bridges to increase the overall capacity. Although regular inspections are carried out, no special method was available to test the bond condition of CFRP laminates after being in Service for more than ten years. The German Center of Competence in Civil Engineering is aware of this need and funded a research project to investigate the bond condition by means of advanced non-destructive testing (NDT). T2 - 31st Danubia-Adria Symposium on advances in experimental mechanics CY - Kempten, Germany DA - 24.09.2014 KW - Concrete bridges KW - Strengthening KW - Non-destructive testing KW - CFRP KW - Durability KW - Inspection PY - 2014 SN - 978-3-00-046740-0 SP - 1 EP - 2 AN - OPUS4-33116 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wolf, Julia A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Helmerich, Rosemarie A1 - Köpp, Christian A1 - Wiggenhauser, Herbert A1 - Kurz, J.H. A1 - Moryson, R.M. A1 - Samokrutov, A. A1 - Alekhin, S. G. A1 - Alver, Ninel A1 - Sazak, H.Ö. T1 - An ultrasound monitoring system for concrete structures N2 - The research project "Ultrasonic Net for Concrete Monitoring (UNeCOM)" aims at developing a methodology for an embedded ultrasonic network for the condition assessment of infrastructure constructions. Civil engineering structures made of concrete, which are located in tectonically active regions or undergo special loading conditions, may require continuous monitoring. It is important to assess the condition of the building and its stability to recognise and classify the effect of a seismic event or evolving damage at early stages before failure occurs. Embedded ultrasonic sensors offer the possibility to detect changes in the material and degradation mechanisms from inside the structure in areas which are difficult or impossible to inspect otherwise. In contrast to conventional ultrasonic testing methods, where the concrete surfaces are scanned with ultrasound probes, this new approach uses sensors, which are embedded into concrete, eliminating the effect of variable coupling conditions between sensors and concrete. This method allows an integral detection of changes in the concrete structure, for example due to seismic activities, to detect mechanical impacts, as well as degradation of the material due to overloading. Such methods have great relevance especially for the monitoring of constructions like power plants, bridges, offshore structures and other structures with high technical safety requirements. The sensor network can be controlled remotely through the internet which is also being used for data transfer. The embedded sensor network is designed to monitor structural damage and concrete degradation globally with high sensitivity. T2 - Istanbul bridge conference 2014 CY - Istanbul, Turkey DA - 11.08.2014 KW - Ultrasound KW - Concrete KW - Monitoring PY - 2014 SN - 978-605-64131-6-2 SP - Paper 32, 1 EP - 9 AN - OPUS4-32028 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Helmerich, Rosemarie A1 - Milmann, Boris A1 - Wöstmann, Jens T1 - Non-destructive detection of surface-bond defects in carbon composite-strengthened concrete structures N2 - For almost 15 years, carbon fibre-reinforced polymer (CFRP) plates and sheets have been used for strengthening and repair of civil engineering structures. CFRP plates were applied to upgrade structures for change in use or increasing traffic load. CFRP laminates have also been used to repair deteriorated structures such as multi-storey parking or bridges. The execution quality and condition of the strengthening measure in terms of bond integrity were neither monitored nor tested systematically. Inspectors eventually applied simple hammer knocking during regular main inspection for subjective noise distinction as a measure for eventual insufficient bond. This paper presents the feasibility and the limitations of low-frequency transversal ultrasonic waves with dry-coupling point-contact sensors for inspection and defect detection between CFRP laminate and concrete surfaces. The German Centre of Competence in Civil Engineering (DIBt) has initiated a national research project [Helmerich et al. (2012). Condition analysis of bonded CFRP-applications on concrete structures by means of non-destructive testing [in German: Zustandsuntersuchung von CFK-Klebeverstärkungen an Betonbauteilen mittels zerstörungsfreier Prüfung (ZfP)]. Final, internal project report], carried out at the Federal Institute for Materials Research and Testing (BAM), Germany. The aim of the project was to present a potential non-destructive testing method for bond defect detection as a measure for the durability of the strengthening system more than 10 years after application. KW - Concrete bridges KW - Strengthening KW - Non-destructive testing KW - Composite materials KW - Durability KW - Inspection PY - 2015 DO - https://doi.org/10.1080/15732479.2013.879322 SN - 1573-2479 VL - 11 IS - 1 SP - 3 EP - 14 PB - Taylor & Francis CY - London [u.a.] AN - OPUS4-33086 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Krause, Martin A1 - Mayer, K. A1 - Ballier, G. A1 - Borchardt, Kerstin A1 - Chinta, P.K. A1 - Effner, Ute A1 - Milmann, Boris A1 - Müller, Sabine A1 - Nowak, Thomas Rudolf T1 - Hochgenaue Strukturerkennung von Holzbauteilen mit 3D-Ultraschall N2 - Inhalt ist die zerstörungsfreie Detailuntersuchung von Holzbauteilen mit einem dreidimensional abbildenden Ultraschall-Echoverfahren. Das neu entwickelte 3D-Verfahren berücksichtigt den anisotropen Aufbau des Holzes. Die Bildschnitte und Projektionen werden aus flächigen Ultraschallaufnahmen berechnet. Die Messungen erfolgen an Probekörpern sowie an Bauteilen aus der Praxis. In dem Forschungsvorhaben wird die für Holz neue 3D-Rekonstruktionsrechnung verwendet und mit dem Ziel weiterentwickelt, unter Berücksichtigung der anisotropen Struktur des Holzes eine dreidimensional aufgelöste Abbildung von Reflektoren im Inneren der Holzbauteile zu ermöglichen. Damit werden die bisher für Holzbauteile zur Verfügung stehenden Verfahren entscheidend ergänzt, weil nun eine hochgenaue dreidimensionale Abbildung erreichbar ist (Auflösung: 20 mm und besser). KW - Ultraschallecho-Verfahren KW - Holzbauteile KW - Abbildungsverfahren KW - Imaging PY - 2014 UR - https://www.irb.fraunhofer.de/bauforschung/baufolit/projekt/Hochgenaue-Strukturerkennung-von-Holzbauteilen-mit-3D-Ultraschall/20138035979 SN - 978-3-8167-9212-3 VL - 109 SP - 1 EP - 101 PB - Fraunhofer IRB Verl. CY - Stuttgart AN - OPUS4-32852 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krause, Martin A1 - Mauke, R. A1 - Effner, Ute A1 - Milmann, Boris A1 - Völker, Christoph A1 - Wiggenhauser, Herbert T1 - Ultrasonic testing of a sealing construction made of salt concrete in an underground disposal facility for radioactive waste T2 - NDT-CE 2015 - International symposium non-destructive testing in civil engineering CY - Berlin, Germany DA - 2015-09-15 KW - Ultrasonic reflection measurement KW - Dry contact transducers in boreholes KW - Interface salt-concrete / rock salt KW - Ultrasonic imaging of internal reflectors PY - 2015 SN - 1435-4934 SP - 696 EP - 699 AN - OPUS4-34537 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mayer, K. A1 - Milmann, Boris A1 - Krause, Martin A1 - Mielentz, Frank T1 - Methode zum Nachweis von Verpressfehlern in Spannbeton durch Phasenauswertung bei Ultraschallecho-Verfahren KW - Ultraschall-Echo-Verfahren KW - Verpressfehler KW - Spannbeton KW - Hüllrohr KW - Brücken PY - 2008 SN - 1616-069X SN - 0948-5112 VL - 112 IS - 12 SP - 37 EP - 40 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung CY - Berlin AN - OPUS4-18685 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Milmann, Boris T1 - Ultraschallecho-Verfahren für Spannbeton: Signifikanter Nachweis von Verpressfehlern mit Phasenauswertung T2 - Fachtagung Bauwerksdiagnose 2008, Praktische Anwendungen Zerstörungsfreier Prüfungen und Zukunftsaufgaben CY - Berlin, Germany DA - 2008-02-21 PY - 2008 AN - OPUS4-18067 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Maierhofer, Christiane A1 - Wöstmann, Jens A1 - Milmann, Boris A1 - Hennen, C. ED - Karl-Eugen Kurrer, ED - Lorenz, Werner ED - Volker Wetzk, T1 - Structural assessment of stone walls of St. Servatius church in Quedlinburg N2 - Non-destructive and minor destructive testing methods enable a classification of historic structures, building processes, applied building technologies and materials. Therefore, these methods should be part of the global investigation of historic buildings which is usually required before the planning of any building intervention. The case study presented herein encompasses experimental work carried out at the St. Servatius Church in Quedlinburg, Germany. Within a comprehensive restoration campaign, non-destructive on-site investigations were carried out with radar and ultrasonics. The results were combined with plans, views and cores recorded in advance. T2 - 3rd International congress on construction history CY - Cottbus, Germany DA - 2009-05-20 KW - Non-destructive testing KW - Radar KW - Ultrasonic KW - Stone KW - Masonry PY - 2009 SN - 978-3-936033-31-1 VL - 2 SP - 983 EP - 990 PB - NEUNPLUS1 - Verlag und Service GmbH AN - OPUS4-19741 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krause, Martin A1 - Milmann, Boris A1 - Feldmann, Rüdiger A1 - Friese, Martin A1 - Wöstmann, Jens A1 - Zoëga, Andreas A1 - Sodeikat, C. T1 - Thickness measurement & quality assurance of floor slabs & diaphragm walls T2 - Structural faults & repair 2010 - International conference and exhibition CY - Edinburgh, Scotland, UK DA - 2010-06-15 KW - Ultrasonic echo KW - Radar KW - Impact-echo KW - Synthetic aperture focusing technique (SAFT) KW - Compaction faults PY - 2010 SN - 0-947644-67-9 SP - 1 EP - 9 PB - Engineering Technics Press CY - Edinburgh, Scotland AN - OPUS4-22897 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krause, Martin A1 - Mayer, K. A1 - Ballier, G. A1 - Friese, Martin A1 - Mielentz, Frank A1 - Milmann, Boris T1 - Darstellung des Verpresszustandes von Spannkanälen mit 3D-Ultraschallechoverfahren: Modellierung und Experiment T2 - DGZfP-Jahrestagung 2010 CY - Erfurt, Deutschland DA - 2010-05-10 KW - Ultraschallecho KW - Rekonstruktionsrechnung KW - SAFT KW - Spannkanäle PY - 2010 SN - 978-3-940283-26-9 IS - DGZfP-BB 122 (Mi.3.B.1) SP - 1 EP - 12 CY - Berlin AN - OPUS4-22900 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Krause, Martin A1 - Milmann, Boris A1 - Mielentz, Frank A1 - Streicher, Doreen A1 - Redmer, Bernhard A1 - Mayer, K. A1 - Langenberg, K.-J. A1 - Schickert, M. T1 - Ultrasonic Imaging Methods for Investigation of Post-tensioned Concrete Structures: A Study of Interfaces at Artificial Grouting Faults and Its Verification N2 - This paper presents the progress of successful location of grouting faults in tendon ducts with ultrasonic imaging. The examples were obtained in the research group FOR 384 funded by DFG (German Research Foundation). The co-operation of experimental research and modeling allowed imaging and identification of grouted and ungrouted areas of tendon ducts (including strands) in a large test specimen (40 m²). In addition to the criteria for indicating grouting faults in post-tensioned ducts known until now the phase evaluation of reflected ultrasonic pulses is described. Experiments and modeling of wave propagation are presented for reflections at metal plates in concrete (thickness range 0.5 mm to 40 mm) and for tendon ducts including strands. The main part of the progress was achieved by automated measurements using dry contact transducers, 3D-SAFT reconstruction including phase evaluation and modeling considering wave propagation for typical elastic parameters and exact experimental site conditions. The results for shear waves as well as for pressure waves are compared in the frequency range from 50 kHz to 120 kHz. KW - Non-destructive testing KW - Tendons KW - Prestressed concrete bridges KW - Ultrasonic echo KW - Reconstruction calculation KW - 3D-SAFT KW - Modeling (EFIT) PY - 2008 DO - https://doi.org/10.1007/s10921-008-0033-5 SN - 0195-9298 SN - 1573-4862 VL - 27 IS - 1-3 SP - 67 EP - 82 PB - Plenum Press CY - New York, NY AN - OPUS4-17922 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Mayer, K. A1 - Langenberg, K.-J. A1 - Krause, Martin A1 - Milmann, Boris A1 - Mielentz, Frank T1 - Characterization of reflector types by phase-sensitive ultrasonic data processing and imaging N2 - Ultrasonic and radar imaging techniques are limited in resolution by the wavelength in the material, yet information beyond those limits is hidden in complex frequency dependent reflection coefficients. The analysis of the phase of complex reflection coefficients together with the properties of imaging algorithms can help to characterize and to classify indications of defects in concrete buildings. This paper describes a method to extract phase information from measurements and SAFT reconstructed images. The influencing factors like material properties, transducer characteristics, and imaging algorithms based on Born or Physical Optics approximations are elaborated. Simulated and experimental results are briefly discussed. KW - NDT KW - Imaging KW - Flaw characterization KW - Tendon ducts KW - Phase analysis KW - Ultrasonic echo KW - SAFT KW - FT-SAFT KW - EFIT-modeling KW - Modellierung KW - EFIT KW - Spannbeton KW - Ultraschallecho KW - Spannkanäle KW - Verpressfehler KW - Zerstörungsfreie Prüfung im Bauwesen KW - ZfP-Bau PY - 2008 DO - https://doi.org/10.1007/s10921-008-0035-3 SN - 0195-9298 SN - 1573-4862 VL - 27 IS - 1-3 SP - 35 EP - 45 PB - Plenum Press CY - New York, NY AN - OPUS4-17926 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Krause, Martin A1 - Mayer, K. A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Streicher, Doreen ED - L. Binda, ED - M. di Prisco, ED - R. Felicetti, T1 - New examples for ultrasonic imaging of prestressed concrete elements T2 - 1st International RILEM Conference, - on Site Assessment of Concrete, Masonry and Timber Structures (SACoMaTiS 2008) CY - Varenna, Italy DA - 2008-09-01 KW - Ultrasonic imaging KW - Grouting condition KW - Elastodynamic Finite Integration Technique (EFIT) PY - 2008 SN - 978-2-35158-062-2 VL - 1 IS - PRO 59 SP - 1 EP - 10 PB - RILEM Publications AN - OPUS4-19069 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Milmann, Boris T1 - Improvement of the near field resolution of ultrasound probes T2 - 10th European Conference on NDT (ECNDT) CY - Moscow, Russia DA - 2010-06-07 PY - 2010 AN - OPUS4-22619 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Müller, H. S. A1 - Fenchel, M. A1 - Wiggenhauser, Herbert A1 - Maierhofer, Christiane A1 - Krause, Martin A1 - Gardei, André A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Röllig, Mathias A1 - Wöstmann, Jens T1 - Zerstörungsfreie Ortung von Gefügestörungen in Betonbodenplatten N2 - Das Ziel des Forschungsvorhabens „Zerstörungsfreie Ortung von Gefügestörungen in Betonbodenplatten“ bestand in der Entwicklung eines Untersuchungskonzepts zur sicheren Ortung und Erfassung von Gefügestörungen in einseitig zugänglichen Betonplatten durch den kombinierten Einsatz verschiedener zerstörungsfreier Prüfverfahren. Hierfür wurde die Leistungsfähigkeit der folgenden Messverfahren hinsichtlich ihrer Aussageschärfe, Anwendungsgrenzen und Messgeschwindigkeit bei praxisnahen Randbedingungen untersucht: - Impakt-Echo, manuelle Impaktauslösung - Impakt-Echo, automatisierte Impaktauslösung - Ultraschall-Echo mit multistatischem Array - Impuls-Thermografie - Radar Als Versuchskörper dienten sechs liegend hergestellte Betonplatten der Abmessungen 200/200/30 cm aus zwei verschiedenen Betongüten und mit unterschiedlichem Bewehrungsgehalt (Bewehrungsgrade 0 %, 0 ,9 %, 2 ,6 %), von denen vier Platten auf trockenem und zwei Platten auf ständig nass gehaltenem Sand gelagert waren. Alle sechs Platten enthielten jeweils dieselben künstlich eingebrachten Fehlstellen: vier quadratische Kiesnester in unterschiedlicher Tiefe mit Kantenlängen zwischen 10 und 15 cm sowie drei oberflächennahe Hohlstellen (Ø 4/6/8 cm). Zur Erfassung eines möglichen Einflusses des Betonalters wurden die Messungen 4 Tage, 28 Tage sowie 180 Tage nach Herstellung der Platten durchgeführt. Um aus den Untersuchungen einen breiten Nutzen für die Praxis zu erzielen, basierten die eingesetzten Messverfahren auf handelsüblichen Geräten, welche jedoch bezüglich ihres Messprinzips und insbesondere der Datenerfassung und -auswertung weiterentwickelt wurden. Die Fehlstellengröße wurde bewusst klein gewählt. Mit Ausnahme des manuellen Impakt-Echo-Verfahrens, mit welchem unter Verwendung der Originalsoftware des Herstellers keine Fehlstellen nachweisbar waren, zeigten sich alle Messverfahren geeignet, unter verschiedenen Randbedingungen Gefügestörungen zu lokalisieren. Insgesamt wurde jeder Fehlstellentyp von zumindest einem Verfahren bei mindestens zwei Versuchskörpern detektiert. Es konnten jedoch an keiner Betonplatte mit einem einzelnen Messverfahren alle vorhandenen Fehlstellen an allen Messterminen geortet werden. Am häufigsten wurden die beiden großen oberflächennahen Fehlstellen (Hohlstelle Ø 8 cm, Kiesnest 10 cm) erkannt. Am schwersten zu lokalisieren waren die kleine Hohlstelle mit 4 cm Durchmesser sowie die beiden auf der Unterseite gelegenen Kiesnester. Die Untersuchungen zeigen, dass für eine erfolgreiche Anwendung zerstörungsfreier Messverfahren in der Praxis die Auswahl des am besten geeigneten Verfahrens bzw. einer Kombination verschiedener Verfahren jeweils auf die vorliegende Problemstellung abgestimmt sein muss. Für Betonbodenplatten mit hohem Feuchtegehalt (junger Beton) oder starker Bewehrung ist entweder das Ultraschall- oder das Impakt-Echo-Verfahren geeignet. Das Ultraschall-Verfahren wird von hohen Bewehrungsgehalten zwar stärker beeinflusst als das Impakt-Echo-Verfahren, besitzt aber eine bessere Auflösung und ermöglicht auch im oberflächennahen Bereich eine quantitative Bestimmung der Fehlstellentiefe. Das Impakt-Echo-Verfahren kann wegen der niederfrequenten Impulsanregung Fehlstellen erst in größeren Tiefen und mit schlechterer Auflösung nachweisen, ist aber ideal geeignet zur Bestimmung der Plattendicke aufgrund seines signifikanten Rückwandechos. Sowohl das Radar-Verfahren als auch die Impuls-Thermografie können bei hohen Feuchte- und Bewehrungsgehalten nur sehr oberflächennah eingesetzt werden. Bei trockenem Beton und geringen bis mittleren Bewehrungsgehalten liefert das Radar-Verfahren sehr gute Ergebnisse. In kurzer Zeit ermöglicht es eine flächendeckende Ortung der Tiefenlage und Größe von Inhomogenitäten bei guter Auflösungsgenauigkeit. Vorhandene Bewehrung wird deutlich abgebildet, kann aber darunterliegende Fehlstellen verschatten. Alternativ kann die Impuls-Thermografie für die Ortung oberflächennaher Gefügestörungen eingesetzt werden. Das Verfahren eignet sich insbesondere bei Oberflächen, die nicht direkt zugänglich sind, da zwischen Infrarotkamera und Messobjekt nur Sichtkontakt bestehen muss. Die Betongüte hatte bei keinem eingesetzten Verfahren einen erkennbaren Einfluss auf die Messergebnisse. Streng genommen ist dies jedoch nur für den Einfluss des Wasserzementwertes, der Zementart und des Zementgehalts bei gleichbleibender Sieblinie und gleicher Kornart gültig. Bei Verwendung von Leichtzuschlag sind abweichende Ergebnisse denkbar. PY - 2010 SN - 978-3-410-65075-1 SN - 0171-7197 IS - 589 SP - 1 EP - 88 PB - Beuth CY - Berlin AN - OPUS4-22699 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Helmerich, Rosemarie A1 - Milmann, Boris ED - Frangopol, D. ED - Sause, R. ED - Kusko, C. T1 - Contribution on non-destructive defect detection to bridge management T2 - IABMAS 2010 - Bridge maintenance, safety, management and life-cycle optimization CY - Philadelphia, PA, USA DA - 2010-07-11 KW - Ultrasonic measurement KW - Transversal waves KW - Bond defect KW - Defect detection KW - Concrete structures KW - Debonded area visualisation PY - 2010 SN - 978-0-415-87786-2 SP - 1 EP - 8(?) PB - CRC Press AN - OPUS4-22680 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Milmann, Boris A1 - Krause, Martin A1 - Mielentz, Frank A1 - Mayer, K. T1 - Ultraschallecho-Verfahren für Spannbeton: Signifikanter Nachweis von Verpressfehlern mit Phasenauswertung T2 - Fachtagung Bauwerksdiagnose - Praktische Anwendungen Zerstörungsfreier Prüfungen und Zukunftsaufgaben CY - Berlin, Deutschland DA - 2008-02-21 KW - Ultraschallecho KW - Spannbeton KW - Verpressfehler KW - Modellierung KW - Polarimetrische Abbildungsverfahren PY - 2008 SN - 978-3-940283-08-5 N1 - Serientitel: Berichtsband der Deutschen Gesellschaft für Zerstörungsfreie Prüfung – Series title: Berichtsband der Deutschen Gesellschaft für Zerstörungsfreie Prüfung IS - 112 SP - 1 EP - 11 (Beitrag 11) PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung CY - Berlin AN - OPUS4-18280 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Krause, Martin A1 - Mayer, K. A1 - Friese, Martin A1 - Milmann, Boris A1 - Mielentz, Frank A1 - Ballier, G. ED - Odile Abraham, ED - Dérobert, Xavier T1 - Progress in ultrasonic tendon duct imaging T2 - NDTCE `09 - 7th international symposium on non destructive testing in civil engineering CY - Nantes, France DA - 2009-06-30 KW - Reconstruction calculation KW - SAFT KW - EFIT Modelling KW - Prestressed concrete structures PY - 2009 SN - 978-2-7208-2542-5 SN - 1628-4704 IS - Paper 77 SP - 147 EP - 154 AN - OPUS4-20652 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Krause, Martin A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Streicher, Doreen A1 - Müller, W. T1 - Ultrasonic Imaging of Concrete Elements - State of the Art Using 2D Synthetic Aperture N2 - Since several years ultrasonic imaging techniques are used for testing concrete elements. Combined with a reconstruction calculation they lead to an acoustic imaging of scatterers and reflectors from the inside of the concrete element. For several testing problems it is an advantage to use a two dimensional synthetic aperture and to combine it with a three-dimensional reconstruction calculation (3D-SAFT, Synthetic Aperture Focussing Technique). This enables the analysis of the tested volume by means of B-scans in two directions and C-scans (projections parallel to the surface), respectively. Using the 2D-scanning technique, especially the disturbing influence of the reinforcing rebars can be minimised. In this contribution the state of the art of this method is demonstrated and analysed. Examples of the application are presented, concerning Localisation of honeycombing and compaction faults Characterisation of cracks (especially measuring the crack depth) Investigation of tendon ducts The results presented are obtained in the frame of a research initiative Non-destructive Evaluation of Concrete Structures Using Acoustic and Electromagnetic Echo-Methods supported by the German Science Council (FOR 384 of DFG, Deutsche Forschungsgemeinschaft). The methods are assessed and improved in cooperation with the partners participating in the project. T2 - 6th International Symposium Non-Destructive Testing in Civil Engineering (NDT-CE) CY - Berlin, Germany DA - 2003-09-16 PY - 2003 UR - http://www.ndt.net/article/ndtce03/papers/v051/v051.htm SN - 3-931381-49-8 PB - DGZfP CY - Berlin AN - OPUS4-2606 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maierhofer, Christiane A1 - Krause, Martin A1 - Mielentz, Frank A1 - Streicher, Doreen A1 - Milmann, Boris A1 - Gardei, André A1 - Kohl, Christoph A1 - Wiggenhauser, Herbert T1 - Complementary application of radar, impact-echo and ultrasonics for testing concrete structures and metallic tendon ducts T2 - 83rd Annual Meeting Transportation Research Board of the National Academies CY - Washington, D. C., USA DA - 2004-01-11 KW - Non-destructive testing KW - Tendon duct KW - Concrete bridge KW - Radar KW - Ultrasonic KW - Impact-echo PY - 2004 SP - 18 pages CY - Washington AN - OPUS4-4909 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Wöstmann, Jens A1 - Krause, Martin A1 - Maierhofer, Christiane A1 - Römer, A. A1 - Völkel, W. T1 - Untersuchungen zur zerstörungsfreien Bestimmung des Hohlraumgehaltes von Asphaltschichten T2 - DGZfP-Fachtagung Bauwerksdiagnose "Praktische Anwendungen Zerstörungsfreier Prüfungen" CY - Berlin, Deutschland DA - 2006-02-22 KW - Asphalt KW - Hohlraumgehalt KW - Zerstörungsfreie Prüfung KW - Ultraschallverfahren KW - Ultraschall-Rückstreuung KW - Radarverfahren PY - 2006 SN - 3-931381-71-4 SP - 1(?) EP - 9(?) PB - DGZfP CY - Berlin AN - OPUS4-12116 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wendrich, Astrid A1 - Trela, Christiane A1 - Krause, Martin A1 - Maierhofer, Christiane A1 - Wöstmann, Jens A1 - Milmann, Boris ED - Mazal, P. T1 - Application of ultrasonic and radar tomography for the investigation of the internal structure of masonry T2 - 3rd International Workshop of NDT Experts CY - Prague, Czech Republic DA - 2005-10-10 KW - Masonry KW - Tomography KW - Ultrasonic KW - Radar KW - Non-destructive testing PY - 2005 SN - 80-2142996-8 SP - 299 EP - 313 PB - Univ. of Technology CY - Brno AN - OPUS4-12273 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CHAP A1 - Krause, Martin A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Mayer, K. T1 - Objektabbildung mit scannenden Ultraschallecho-Verfahren KW - ZfPBau KW - Ultraschallecho KW - Betonbauteile KW - Spannkanäle KW - Phased Array KW - Rekonstruktionsrechnung KW - Modellierung elastischer Wellen PY - 2006 SN - 978-3-433-01833-0 SN - 0342-7617 VL - 1 IS - Kap. V / Abschnitt 8 SP - 543 EP - 554 PB - Ernst CY - Berlin AN - OPUS4-14272 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krause, Martin A1 - Milmann, Boris A1 - Schickert, M. A1 - Mayer, K. T1 - Investigation of Tendon Ducts by Means of Ultrasonic Echo Methods - A Comparative Study T2 - 9th European Conference on NDT CY - Berlin, Germany DA - 2006-09-25 KW - NDT-CE KW - Concrete KW - Tendon ducts KW - Ultrasonic echo KW - Ultrasonic imaging KW - Grouting faults PY - 2006 SN - 3-931381-86-2 SP - 1(?) EP - 12(?) PB - European Federation for Non-Destructive Testing CY - Berlin AN - OPUS4-14224 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mayer, K. A1 - Langenberg, K.-J. A1 - Krause, Martin A1 - Maierhofer, Christiane A1 - Milmann, Boris A1 - Kohl, Christoph T1 - Characterization of ultrasonic and radar reflector types in concrete by phase evaluation of the signal and the reconstructed image T2 - 9th European Conference on NDT CY - Berlin, Germany DA - 2006-09-25 KW - NDT-CE KW - Ultrasonic echo KW - Radar KW - Phase evaluation KW - Modeling of wave propagation KW - Reconstruction calculation PY - 2006 SN - 3-931381-86-2 SP - 1 EP - 8(?) PB - European Federation for Non-Destructive Testing CY - Berlin AN - OPUS4-14225 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Krause, Martin A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Streicher, Doreen A1 - Mayer, K. T1 - Ultrasonic Reflection Properties at Interfaces Between Concrete Steel and Air: Imaging and Modelling T2 - NDE Conference on Civil Engineering CY - St. Louis, Missouri, USA DA - 2006-08-14 KW - Ultrasonic echo KW - Concrete PY - 2006 SN - 1-57117-148-7 SP - 472 EP - 479 PB - ASTM CY - St. Louis AN - OPUS4-14239 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Maierhofer, Christiane A1 - Zacher, Gerhard A1 - Wöstmann, Jens A1 - Krause, Martin A1 - Streicher, Doreen A1 - Milmann, Boris T1 - Bewertung von Radar- und Ultraschalldaten mit Hilfe der Datenfusion T2 - DGZfP-Jahrestagung 2007 CY - Fürth, Deutschland DA - 2007-05-14 KW - ZfPBau KW - Stahlbeton KW - Spannbetonbrücken KW - Bewehrung KW - Spannglieder KW - Radar KW - Ultraschall KW - Datenfusion PY - 2007 SN - 978-3-931381-98-1 SP - 1 EP - 8 PB - DGZfP CY - Berlin AN - OPUS4-15991 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Krause, Martin A1 - Mayer, K. A1 - Friese, Martin A1 - Milmann, Boris A1 - Mielentz, Frank A1 - Ballier, G. T1 - Progress in ultrasonic tendon duct imaging N2 - Ultrasonic imaging of tendon ducts enables the precise localisation of grouting faults in many cases. Additionally to well known criteria for detecting grouting faults in tendon ducts recently new possibilities were developed. Two main effects influence the complex behaviour of wave propagation and reflection: a) different arrangement and number of strands or internal rebars; b) superposition of reflecting signals and different wave modes propagating into the interface region around the tendon duct. In order to understand the experimental results, EFIT modelling is performed (EFIT: Elastodynamic Finite Integration Technique). KW - Ultrasonic imaging KW - Prestressed concrete structures KW - Reconstruction calculation KW - SAFT KW - EFIT modelling PY - 2011 DO - https://doi.org/10.3166/ejece.15.461-485 SN - 1964-8189 VL - 15 IS - 4 SP - 461 EP - 485 PB - Lavoisier CY - Paris AN - OPUS4-23853 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Shokouhi, Parisa A1 - Wöstmann, Jens A1 - Schneider, Gerhard A1 - Milmann, Boris A1 - Taffe, Alexander A1 - Wiggenhauser, Herbert T1 - Nondestructive detection of delamination in concrete slabs - multiple-method investigation N2 - The delamination of concrete slabs is the separation along a plane roughly parallel to, and generally near, the surface. Corrosion-induced delamination is a common problem in old concrete bridge decks. If undetected, delaminations could expand, reach the surface, and result in spalling. Early detection of delamination is necessary for planning timely repairs that prevent costly deck replacement projects. Most bridge owners rely on routine visual and traditional surveys of bridge deck conditions. These surveys are highly subjective and can locate only large shallow delaminated zones. Several nondestructive testing (NDT) techniques have recently been employed for bridge deck evaluation to obtain more objective and comprehensive assessment. The reliability of applicable methods needs to be established before a greater role for NDT in routine inspections can be encouraged. This paper presents a validation study aimed at evaluating the effectiveness of three NDT techniques, namely impact echo, ultrasound (US) echo, and US linear array, in detection of delamination. This study is unique because the subject test specimens were deteriorated bridge deck segments preserved from the demolition of a prestressed box girder bridge. The results of the tests conducted on one of the specimens are presented and discussed here: impact echo provided satisfactory overall assessment, but the individual results were often difficult to interpret; US echo detected deep delaminations but not shallow ones; and US linear array located the extent of deep delaminations and provided indications of shallow ones. KW - Delamination KW - Concrete KW - Ultrasonic testing KW - Impact echo KW - Scanning PY - 2011 DO - https://doi.org/10.3141/2251-11 SN - 0361-1981 VL - 2251 SP - 103 EP - 113 PB - National Research Council CY - Washington, DC AN - OPUS4-25552 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Helmerich, Rosemarie A1 - Milmann, Boris A1 - Wöstmann, Jens A1 - Feistkorn, S. ED - Barros, J. ED - Sena-Cruz, J. T1 - Durability of CFRP-laminate strengthening N2 - First bridge structures have been strengthened by means of Carbon-Fiber-Reinforced-Polymer (CFRP)-laminates extemally glued to the concrete surface in the last two decades. At present there is no Information about the durability of these Systems after having been in Service for more than ten years. The paper presents laboratory tests and case studies with automated non-destructive testing to analyse the current bond condition of extemally bonded CFRP-laminates to concrete structures, strengthened about ten years ago. The paper presents the feasibility and the limitations of ultrasonic inspection of selected areas of CFRP-laminate-strengthened structures co-funded by the German Center of Competence in Civil Engineering (DIBt) in a national project. Areas of interest were the end region of laminates or areas with educated doubts about their bond integrity selected and marked in the inspection records during main inspections. In a feasability study, the functionality of the ultrasonic test for bond evaluation below CFRP-laminates without any surface protection measure, was confirmed by testing a CFRP-laminate strengthened slab with artificial voids in a blind laboratory test with an accuracy of + 1 cm. The accuracy depends on the step width, line interspace and the distance between ultrasonic transducer and receiver. This accuracy suits a measuring grid of 1 cm. The case studies consider flexural strengthening and repair of prestressed concrete structures as well as longitudinal and transverse strengthening of bridge slabs with simple reinforcement. Both alternatives were considered, covered with mineral surface protection layer and without. The measurement results of automated scanned surfaces is presented in color-codes images. In the tested areas with no or thin surface protection the non-destructive inspection did not uncover severe defects or Deterioration processes. None the less, proposals for further research is given, in testing of the acceptable bond defects and in advancing the ultrasonic test including the devlopment of sensors for this application. T2 - FRPRCS-11 - 11th International symposium on fiber reinforced polymer for reinforced concrete structures CY - Guimaraes, Portugal DA - 26.06.2013 KW - CFRP-Laminate KW - Debonding KW - Flexural strengthening KW - Bridge KW - NDT KW - Durability test KW - Inspection PY - 2013 SN - 978-972-8692-84-1 SP - 41 EP - 42 (Session 6.5) AN - OPUS4-28859 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Helmerich, Rosemarie A1 - Milmann, Boris A1 - Wöstmann, Jens A1 - Röllig, Mathias A1 - Kind, Thomas A1 - Lai, W. T1 - Qualitätssicherung für textilfaserverstärkten Beton N2 - Beim Bauen im Bestand ist die zusätzlich aufzunehmende Last in der Regel zu beschränken. Das trifft insbesondere für schon gerissene Elemente wie Gewölbe odör alternde Betonkonstruktionen zu. Da Hochleistungsfasern wie Textilgelege aus Carbonfasern oder alkaliresistenten (AR-)Glasfasern keinen Korrosionsschutz erfordern, kann die Verbundschicht aus Feinkornbeton dünn gehalten werden, um das Bauwerk nur mit einer Mindestzusatzlast zu beanspruchen. Textilbeton heißt die neue Bauweise, für die es zurzeit noch kein festgeschriebenes Qualitätssicherungs- und Wartungskonzept für Bau und die spätere Nutzung gibt. T2 - 5. Anwendertagung Textilbeton CY - Friedrichshafen, Germany DA - 24.09.2013 KW - Textilfaserverstärkter Beton KW - Zerstörungsfreie Prüfung KW - Ultraschall-Echo KW - Radar-Echo PY - 2013 VL - 9 SP - 22 AN - OPUS4-29512 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wolf, Julia A1 - Milmann, Boris A1 - Helmerich, Rosemarie A1 - Köpp, Christian A1 - Mielentz, Frank A1 - Wiggenhauser, Herbert A1 - Kurz, J.H. A1 - Moryson, R.-M. A1 - Samokrutov, A. A1 - Alekhin, S. G. A1 - Alver, Ninel A1 - Sazak, H.-Ö. ED - Xu, Y. L. ED - Zhu, S. ED - Xia, Y. ED - Ni, Y.Q. ED - Law, S.S. ED - Yin, J. H. ED - Su, Z.Q. T1 - Ultrasound based monitoring system for concrete monolithic objects N2 - Ultrasound sensors should be embedded into concrete for monitoring concrete properties. These new longitudinal wave sensors with a center frequency of 60 kHz were examined regarding their suitability for ultrasonic measurements in concrete structures in terms of emission characteristics, sensitivity and frequency ränge. For the measurement of the radiation patterns, the sensors were embedded vertically and horizontally in concrete cylinders. The directivity pattern was measured using a laser vibrometer. The sensitivity of the sensor was determined in water using different sensors of the same type. It shows changes in the signal amplitude as well as variations in the frequency ränge for different transmitter-receiver combinations. The attenuation of the concrete affects the achievable resolution of the measurements and thus, the maximum possible spacing of the sensors within a concrete element. Experimental tests helped optimizing the distances with respect to the required resolution and the effort of embedding the sensors. The signal attenuation in the concrete was measured in the frequency ränge of 60 kHz in response to various degrees of reinforcement and grain size. For this purpose, the sensors were cast at different distances in the specimens studied. The recorded Signals were evaluated for their amplitude and frequency spectrum. T2 - SHMII-6 - 6th International conference on structural health monitoring of intelligent infrastructure CY - Hong Kong, China DA - 09.12.2013 KW - Ultrasound KW - Concrete KW - Monitoring system KW - Ultrasonic network KW - Embedded sensor PY - 2013 SN - 978-962-367-768-4 SP - 1 EP - 6 AN - OPUS4-29642 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Krause, Martin A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Wiggenhauser, Herbert A1 - Müller, W. A1 - Schmitz, V. T1 - Ultrasonic imaging of concrete members using an array system KW - Ultrasonic echo KW - Array technique KW - SAFT (Synthetic Aperture Focusing Technique) KW - Tunnels KW - Reinforced concrete KW - Prestressing ducts PY - 2001 SN - 0963-8695 VL - 34 SP - 403 EP - 408 PB - Butterworth-Heinemann CY - Oxford AN - OPUS4-1082 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Krause, Martin A1 - Müller, W. A1 - Crail, S. T1 - Zerstörungsfreie Risscharakterisierung in Betonbauteilen mit Ultraschall N2 - Die Risstiefenbestimmung in Festen Fahrbahnen ist hinsichtlich der Dauerhaftigkeit der Konstruktion von wesentlichem Interesse. Im Rahmen eines gemeinsamen Forschungsvorhabens mit der DB AG wurden aus der Literatur bekannte Ansätze bewertet und darauf aufbauend ein Verfahren zur bildgebenden Rissdarstellung entwickelt. Rissüberbrückende Bewehrung sowie Kontaktstellen zwischen den Rissflanken wirken als Schallbrücken und erschweren die Risscharakterisierung, wie bei einem Einsatz an einer Betriebserprobungsstrecke festgestellt wurde. Ein aus der Literatur bekanntes Verfahren der einfachen Laufzeitmessung erwies sich für die Tiefenbestimmung von realen verunreinigten Rissen als ungeeignet. T2 - Fachtagung Bauwerksdiagnose - Praktische Anwendungen Zerstörungsfreier Prüfungen CY - Leipzig, Germany DA - 25.10.2001 PY - 2001 VL - 76-CD SP - 1 EP - 10 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-1188 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mittag, Kornelia A1 - Colla, Camilla A1 - Krause, Martin A1 - Maierhofer, Christiane A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Schneider, Gerhard A1 - Wöstmann, Jens A1 - Wiggenhauser, Herbert T1 - Zerstörungsfreie Messungen zur Beurteilung des inneren Zustandes fester Fahrbahnen der Deutschen Bahn AG: Vergleichsmessungen an Probeaufbauten im Labor N2 - Im Rahmen eines FE-Projektes “Inspektion Fester Fahrbahnen“ der BAM und der Deutschen Bahn AG geht es um die Anwendung und weitere Entwicklung zerstörungsfreier Messverfahren zur Beurteilung des Zustandes Fester Fahrbahnen. Nach ersten Versuchsreihen direkt im Gleis wurden für verschiedene Bauarten die charakteristischen Herstellungsbedingungen simuliert und systematisch untersucht. Die kombinierte Anwendung der drei Messverfahren Ultraschall-Array-, Impakt-Echo- und Impuls-Radar-Verfahren wird hier an dem Beispiel “Betonschwelle in Betoneinbettung” dargestellt. T2 - Fachtagung Bauwerksdiagnose - Praktische Anwendungen Zerstörungsfreier Prüfungen CY - Leipzig, Germany DA - 25.10.2001 KW - Impakt-Echo-Messverfahren KW - Impuls-Radar-Messverfahren KW - Ultraschall-Array-Messverfahren PY - 2001 VL - 76-CD SP - 1 EP - 8 PB - Deutsche Gesellschaft für Zerstörungsfreie Prüfung (DGZfP) CY - Berlin AN - OPUS4-1201 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst A1 - Wiggenhauser, Herbert A1 - Milmann, Boris T1 - LAUS - Erste praktische Erfahrungen mit einem neuartigen Ultraschallsystem großer Eindringtiefe N2 - Konventionelle Systeme zur Ultraschall-Echo-Prüfung von Betonbauteilen sind in ihrer Eindringtiefe auf etwa einem Meter begrenzt. Zur Prüfung stärkerer Objekte war die Entwicklung eines neuartigen Prüfsystems notwendig. Das LAUS-System (Large Aperture UltraSound) besteht aus 12 einzelnen Arrays, die mit jeweils 32 Einzelprüfköpfen (Scherwellen, 25 – 50 kHz) als Sender oder Empfänger betrieben werden können. Sie werden unabhängig auf Betonoberflächen mit Unterdruck befestigt und kommunizieren drahtlos untereinander und mit der Zentraleinheit. Alle möglichen Kombinationen ergeben 132 Einzelmessungen, die zur Rekonstruktion des durchschallten Volumens genutzt werden. Mehrere dieser Datensätze lassen sich zu einer 3D-Auswertung kombinieren. Das System wurde an mehreren Testobjekten und Bauwerken erfolgreich erprobt. So konnte die fünf Meter dicke, sehr stark bewehrte Fundamentplatte des Fallturms auf dem BAM-Testgelände bei Horstwalde durchschallt werden. Ein zweites Beispiel ist die erfolgreiche Detektion von Spannkanälen in 1,8 m Tiefe in einem massiven Brückenbauwerk. T2 - Fachtagung Bauwerksdiagnose 2018 CY - Berlin DA - 15.2.2018 KW - Beton KW - Ultraschall KW - LAUS KW - Brücke KW - Fundament PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-445786 UR - https://www.bauwerksdiagnose2018.de/Portals/bauwerksdiagnose2018/BB/16.pdf SP - Paper 16, 1 EP - 8 CY - Berlin AN - OPUS4-44578 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Krause, Martin A1 - Borchardt, Kerstin A1 - Lange, Marco A1 - Behrens, Matthias A1 - Maack, Stefan A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Schaurich, Dieter A1 - Wöstmann, Jens A1 - Hintzpeter, F. A1 - Sodeikat, C. T1 - Kosteneinsparung durch Anwendung zerstörungsfreier Prüfverfahren für Betonbauteile beim Bauen im Bestand N2 - In Zeiten knapper Kassen wird überall nach Wegen gesucht Kosten einzusparen. Im Bauwesen geht es dabei um Kosteneinsparungen ohne Reduktion der Sicherheit und Dauerhaftigkeit des Bauwerks. Beim Bauen im Bestand können mit einer zerstörungsfreien Prüfung von Bauwerken die Weiternutzung oder die erforderlichen Umbauten optimiert werden und so Kosten eingespart werden. KW - Zerstörungsfreie Prüfung KW - Bauen im Bestand KW - Radar KW - Ultraschallecho KW - Kosteneinsparung PY - 2011 SN - 978-3-8167-8611-5 VL - 101 SP - 1 EP - 95 PB - Fraunhofer IRB Verl. CY - Stuttgart ET - Abschlussbericht AN - OPUS4-26649 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Helmerich, Rosemarie A1 - Niederleithinger, Ernst A1 - Milmann, Boris A1 - Wöstmann, Jens A1 - Röllig, Mathias A1 - Feldmann, Rüdiger A1 - Täljsten, B. ED - Masoud Motavalli, T1 - Near surface mounted CFRP-rods - preparation of reinforcing measures and quality control by means of non-destructive testing T2 - 4th International Conference on FRP Composites in Civil Engineering (CICE2008) CY - Zurich, Switzerland DA - 2008-07-22 PY - 2008 SN - 978-3-905594-50-8 SP - 1 EP - 6 AN - OPUS4-17747 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Taffe, Alexander A1 - Niederleithinger, Ernst A1 - Krause, Martin A1 - Milmann, Boris T1 - Zerstörungsfreie Untersuchungen an Fundamentplatten mit Ultraschallecho KW - Zerstörungsfreie Prüfung im Bauwesen KW - ZfPBau KW - Ultraschallecho KW - Dickenmessung KW - Fundamente KW - Baustellenscanner KW - Wiedernutzung PY - 2004 SN - 0005-9900 SN - 1437-1006 VL - 99 IS - 12 SP - 1000 EP - 1004 PB - Ernst CY - Berlin AN - OPUS4-5284 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Taffe, Alexander A1 - Krause, Martin A1 - Milmann, Boris A1 - Niederleithinger, Ernst ED - Alexander, M. T1 - Assessment of foundation slabs with US-echo in the re-use process N2 - During the re-use process of existing concrete memebers like foundations information about geometry and location of piles or strip foundation is necessary. Ultrasonic echo with a need of only one-sided access may provide this information and help the engineer to assess foundations. Cost effectiveness by the re-use of foundations gains an increasing economic role due to decreasing average economic lifetime of buildings on urban sites. Results of systematic ultrasonic echo investigations at a slab from 75 cm to 125 cm thickness with ten different reinforcement ratios are presented. The influence of the varying reinforcement ratio and thickness on the reliability of the results is shown. Available data-processing algorithms based on reconstruction calculation and imaging of results to reveal the geometry of a slab and the location of piles or strip foundations are introduced. Practical guidance for the application of ultrasonic echo and its limits are presented to ensure reliable results. T2 - International Conference on Concrete Repair, Rehabilitation and Retrofitting (ICCRRR) CY - Cape Town, South Africa DA - 2006-11-21 KW - Ultraschallecho KW - Fundamentdicke KW - Bildgebende Darstellung KW - Wiedernutzung von Fundamenten KW - SAFT KW - ZfP im Bauwesen KW - Objektortung PY - 2006 SN - 0-415-39654-9 N1 - Serientitel: Balkema proceedings and monographs in engineering, water and earth sciences – Series title: Balkema proceedings and monographs in engineering, water and earth sciences SP - 525 EP - 530 PB - Taylor & Francis CY - London AN - OPUS4-11681 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wiggenhauser, Herbert A1 - Niederleithinger, Ernst A1 - Milmann, Boris T1 - Zerstörungsfreie Ultraschallprüfung dicker und hochbewehrter Betonbauteile T1 - Nondestructive testing of thick and highly reinforced concrete structures with ultrasound N2 - Ein Ultraschallsystem mit großer Apertur, genannt LAUS – Large Aperture UltraSound, wird vorgestellt und die technischen Eigenschaften erläutert. Es besteht aus zwölf Prüfköpfen, die beliebig auf Betonoberflächen mit Unterdruck befestigt und jeweils als Sender oder Empfänger genutzt werden. Alle möglichen Kombinationen ergeben 132 Einzelmessungen, die zur Rekonstruktion des durchschallten Volumens genutzt werden. Das System wurde an zwei Bauwerken erfolgreich erprobt. Die Dicke einer sehr stark bewehrten Fundamentplatte eines Fallturms wurde bestimmt. Die Messungen erfolgten in einem Raster auf einer Fläche von 2,0 × 1,8 m2 und die Rückseite konnte eindeutig abgebildet werden. Weitere Anzeigen aus dem Inneren der Platte zeigen das Potenzial des Systems. An einem Brückenbauwerk wurden indirekt Verdichtungsmängel lokalisiert. Dazu wurden mit dem LAUS-System die im Brückenträger verlaufenden Spannkanäle durch fast 2 m Beton abgebildet. N2 - An ultrasound system with a large aperture, called LAUS - Large Aperture UltraSound, is presented and the technical characteristics are explained. It consists of twelve sensor units which can be attached independently on concrete surfaces with vacuum and which are used as transmitters or receivers respectively. All possible combinations result in 132 individual measurements which are used to reconstruct the insonificated volume. The system has been successfully tested on two structures. The thickness of a very heavily reinforced foundation slab of a drop tower was determined. The measurements were carried out in a grid on a surface of 2.0 x 1.8 m(2) and the back side could be clearly imaged. Further indications from inside the foundation show the potential of the system. Voids in concrete were indirectly located in a bridge structure. For this purpose, the LAUS system was used to image the tendon ducts running in the bridge beam through almost 2 m of concrete. KW - Ultraschall KW - Beton KW - Brücke KW - Fundament KW - LAUS PY - 2017 DO - https://doi.org/10.1002/bate.201700040 SN - 0932-8351 VL - 94 IS - 10 SP - 682 EP - 688 PB - Ernst & Sohn CY - Berlin AN - OPUS4-42614 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Niederleithinger, Ernst A1 - Wiggenhauser, Herbert A1 - Milmann, Boris T1 - LAUS - Erste praktische Erfahrungen mit einem neuartigen Ultraschallsystem großer Eindringtiefe N2 - Konventionelle Systeme zur Ultraschall-Echo-Prüfung von Betonbauteilen sind in ihrer Eindringtiefe auf etwa einem Meter begrenzt. Zur Prüfung stärkerer Objekte war die Entwicklung eines neuartigen Prüfsystems notwendig. Das LAUS-System (Large Aperture UltraSound) besteht aus 12 einzelnen Arrays, die mit jeweils 32 Einzelprüfköpfen (Scherwellen, 25 – 50 kHz) als Sender oder Empfänger betrieben werden können. Sie werden unabhängig auf Betonoberflächen mit Unterdruck befestigt und kommunizieren drahtlos untereinander und mit der Zentraleinheit. Alle möglichen Kombinationen ergeben 132 Einzelmessungen, die zur Rekonstruktion des durchschallten Volumens genutzt werden. Mehrere dieser Datensätze lassen sich zu einer 3D-Auswertung kombinieren. Das System wurde an mehreren Testobjekten und Bauwerken erfolgreich erprobt. So konnte die fünf Meter dicke, sehr stark bewehrte Fundamentplatte des Fallturms auf dem BAM-Testgelände bei Horstwalde durchschallt werden. Ein zweites Beispiel ist die erfolgreiche Detektion von Spannkanälen in 1,8 m Tiefe in einem massiven Brückenbauwerk. T2 - Bauwerksdiagnose 2018 CY - Berlin, Germany DA - 15.2.2018 KW - Ultraschall KW - Beton KW - LAUS KW - Brücke KW - Fundament PY - 2018 AN - OPUS4-44577 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Mayer, K. A1 - Krause, Martin A1 - Wiggenhauser, Herbert A1 - Milmann, Boris T1 - Investigations for the improvement of SAFT imaging quality of a large aperture ultrasonic system N2 - In parallel to the hardware development of an ultrasonic system for the investigation of thick concrete structures, a software package for interactive reconstruction of data for that special arrangement of ultrasonic transducers was developed. The system which is presented in a further contribution to this conference as "large aperture ultrasonic system" (LAUS) requires special features to the evaluation software because measuring positions can be in a non equidistant grid and there is the possibility to improve the measurement by adding measuring points interactively. Starting from theoretical considerations to the image generation by measuring arrangements of synthetic aperture problems, solution approaches for imaging with SAFT (Synthetic Aperture Focusing Technique) algorithms in space and frequency domain of data from insufficient grid density are presented. A wide range of issues that may arise in the application is precalculated by simulations and experimental studies, so that unavoidable artifacts can be identified and classified. A special focus is put on the application of thick concrete structures considering missing measuring points in a grid, grating lobes and surface waves. T2 - NDT-CE 2015 - International symposium non-destructive testing in civil engineering CY - Berlin, Germany DA - 15.09.2015 KW - Ultraschallecho-Verfahren KW - Betonbauteile KW - Grating lobe reduction KW - Linear array KW - Synthetic aperture focusing technique (SAFT), KW - Ultrasound imaging PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-346421 SN - 1435-4934 SP - 1026 EP - 1034 PB - Technische Universität Berlin / Bundesanstalt für Materialforschung und -prüfung AN - OPUS4-34642 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Helmerich, Rosemarie A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Adam, Louisa A1 - Villalobos, S. A1 - Guimaraes, M. A1 - Wiggenhauser, Herbert T1 - Detection of cracks perpendicular to the surface using acoustic methods N2 - Cracks perpendicular to the surface may be initial indicators for a deterioration process of concrete structures. Moisture penetrates inside the structure and transports adverse chemicals. The paper presents an investigation about the reliability of available commercial non-destructive evaluation techniques to reliably estimate the depth of surface-breaking cracks in reinforced concrete structures. Aim of the study was the investigation of surface-braking cracks under laboratory conditions. Commercial acoustic devices as impact echo equipment, single ultrasonic transducers and arrays were applied even if they have not been developed for this purpose. The commercial software and descriptions for application was followed strictly to compare the function, precision and repeatability of the measurements. Both, perpendicular notches and cracks have been considered. The study was completed with a discussion about reference specimens. The study was the basis for formulation of gaps in research. The Electric Power Research Institute (EPRI) has initiated and funded a Project. T2 - NDT-CE 2015 - International symposium non-destructive testing in civil engineering CY - Berlin, Germany DA - 15.09.2015 KW - Acoustic test KW - Commercial acoustic devices KW - Ultrasonic test KW - Crack depth KW - Concrete specimens PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-345729 UR - https://www.ndt.net/?id=18412 SN - 1435-4934 VL - 20 IS - 11 SP - 1 EP - 9 PB - NDT.net CY - Kirchwald AN - OPUS4-34572 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Feldmann, Rüdiger A1 - Zoёga, Andreas A1 - Milmann, Boris A1 - Krause, Martin T1 - Ortung tiefliegender Bewehrung durch Ultraschall mit bildgebender Phasenauswertung N2 - Die Ortung von schlaffer Bewehrung in Beton erfolgt routinemäßig mit bildgebenden Radar- oder Wirbelstromverfahren. Die Anwendung dieser Verfahren ist aber begrenzt, wenn es sich um die Ortung tiefliegender Bewehrung (ab ca. 30 cm) oder um jungen Beton handelt. Grund ist die Schwächung der Radarpulse durch oberflächennahe Bewehrung oder durch die Betonfeuchte. Das bildgebende Ultraschallechoverfahren bietet den Vorteil, dass die Ultraschallpulse in diesen Fällen eine wesentlich höhere Eindringtiefe erreichen. Im vorliegenden Beitrag wird eine Fallstudie vorgestellt, bei der mehrlagig eingebrachte Bewehrungseisen in einer nur einseitig zugänglichen 60 cm dicken Betonplatte geortet werden sollten, um eine Kernbohrung ohne Verkanten der Bohrkrone durchzuführen. Zur Ortung der Bewehrung wurde das Ultraschallechoverfahren mitScherwellen der Mittenfrequenz 50 kHz mit einem automatisch arbeitenden Bauwerksscanner eingesetzt. Aus den flächig aufgenommenen Messdaten wurde mit der Rekonstruktionsrechnung nach dem Prinzip der synthetischen Apertur (SAFT, Synthetic Aperture Focusing Technique) die Position der Bewehrungseisen bildhaft ortsgenau dargestellt. Dies gelingt mit einer Auswertungsoption, bei der die Phase der reflektierten Ultraschallpulse ermittelt und farbcodiert dargestellt wird (Phasenauswertung). Damit lassen sich Reflexionen der Bewehrung eindeutig von eventuellen Fehlstellen oder Rückwandechos unterscheiden. T2 - Fachtagung Bauwerksdiagnose 2014 CY - Berlin, Germany DA - 13.02.2014 KW - Ultraschallecho-Verfahren KW - SAFT KW - Bewehrung KW - Beton KW - Abbildungsverfahren PY - 2014 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-351056 UR - https://www.ndt.net/?id=15885 SN - 1435-4934 VL - 19 IS - 8 SP - 1 EP - 11 PB - NDT.net CY - Kirchwald AN - OPUS4-35105 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wolf, Julia A1 - Mielentz, Frank A1 - Milmann, Boris A1 - Wiggenhauser, Herbert T1 - Grundlagenuntersuchungen von Ultraschall-Sensoren in Beton N2 - Für Ultraschallmessungen in Betonbauteilen wurden neuartige radialsymmetrisch abstrahlende Longitudinalwellenprüfköpfe mit einer Mittenfrequenz von 60 kHz auf deren Eignung hinsichtlich Abstrahlcharakteristik, Empfindlichkeit und Frequenzspektrum untersucht. Für die Messung der Abstrahlcharakteristiken wurden die Prüfköpfe vertikal und horizontal in Betonzylinder eingebettet und die Richtungsabhängigkeiten der Schallschnelle mithilfe eines Laservibrometers gemessen. Die Streuung der Prüfkopfempfindlichkeit wurde im Wasserbad unter Verwendung verschiedener Köpfe gleicher Bauart bestimmt. Außer Änderungen der Signalamplituden zeigten sich auch Schwankungen im Frequenzbereich bei verschiedenen Sender-Empfängerkombinationen. Die Schallschwächung des Betons hat Einfluss auf die erreichbare Auflösung der Messungen und damit auf die maximal möglichen Senderabstände im Bauteil. Durch experimentelle Untersuchungen und Simulationen erfolgte eine Optimierung der Abstände hinsichtlich des Aufwandes und der geforderten Auflösung. Die Signalschwächung im Beton wurde mit verschiedenen Impulsen im Frequenzbereich von 50 kHz bis 100 kHz in Abhängigkeit verschiedener Bewehrungsgrade und Korngrößen ermittelt. Hierfür wurden die Sensoren in unterschiedlichen Abständen in die Probekörper einbetoniert und die Empfangssignale hinsichtlich Amplitudenabfall und Frequenzspektrum untersucht. T2 - DGZfP-Jahrestagung 2013 CY - Dresden, Germany DA - 06.05.2013 PY - 2013 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-294153 SN - 978-3-940283-49-8 IS - DGZfP-BB 141 (Poster 56) SP - 1 EP - 9 PB - Deutsche Gesellschaft für zerstörungsfreie Prüfung e.V. (DGZfP) AN - OPUS4-29415 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Krause, Martin A1 - Mauke, R. A1 - Effner, Ute A1 - Milmann, Boris A1 - Völker, Christoph A1 - Wiggenhauser, Herbert T1 - Ultrasonic testing of a sealing construction made of salt concrete in an underground disposal facility for radioactive waste N2 - For the closure of radioactive waste disposal facilities engineered barriers- so called “drift seals” are used. The purpose of these barriers is to constrain the possible infiltration of brine and to prevent the migration of radionuclides into the biosphere. In a rock salt mine a large scale in-situ experiment of a sealing construction made of salt concrete was set up to prove the technical feasibility and operability of such barriers. In order to investigate the integrity of this structure, non-destructive ultrasonic measurements were carried out. Therefore two different methods were applied at the front side of the test-barrier: 1 Reflection measurements from boreholes 2 Ultrasonic imaging by means of scanning ultrasonic echo methods This extended abstract is a short version of an article to be published in a special edition of ASCE Journal that will briefly describe the sealing construction, the application of the non-destructive ultrasonic measurement methods and their adaptation to the onsite conditions -as well as parts of the obtained results. From this a concept for the systematic investigation of possible contribution of ultrasonic methods for quality assurance of sealing structures may be deduced. T2 - NDT-CE 2015 - International symposium non-destructive testing in civil engineering CY - Berlin, Germany DA - 2015-09-15 KW - Ultrasonic reflection measurement KW - Dry contact transducers in boreholes KW - Interface salt-concrete / rock salt KW - Ultrasonic imaging of internal reflectors PY - 2015 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-346203 UR - http://www.ndt.net/?id=18304 SN - 1435-4934 VL - 20 IS - 11 SP - 1 EP - 4 PB - NDT.net CY - Kirchwald AN - OPUS4-34620 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hong, Shuxian A1 - Lai Wai-Lok, Wallace A1 - Helmerich, Rosemarie A1 - Milmann, Boris ED - Biondini, F. ED - Frangopol, D.M. T1 - NDT-based monitoring of accelerated steel corrosion in concrete N2 - This paper presents an example of monitoring the corrosion process with NDT techniques. The impressed current technique was used for accelerating reinforcement corrosion in a large-sized concrete slab with chloride contamination. Periodic NDT-CE inspections were carried out making use of ground penetrating radar (GPR), ultrasonic echo array and half-cell potential measurement. The work presents an example of monitoring the corrosion process with NDT techniques and shows the way to the ultimate goal of finding objective tools to evaluate the corrosion state. The work was carried out during the Initial Training Network SmartEN, funded by the European Commission. T2 - IABMAS 2012 - 6th International conference on bridge maintenance, safety and management CY - Stresa, Lake Maggiore, Italy DA - 08.07.2012 KW - Concrete KW - Reinforcement corrosion KW - Nondestructive testing KW - Ground penetration radar KW - Ultrasonic echo PY - 2012 SN - 978-0-415-62124-3 SN - 978-0-203-10338-8 SP - 1 EP - 8 PB - CRC Press CY - London, UK AN - OPUS4-29581 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -