TY - JOUR A1 - Belsey, N. A. A1 - Cant, D. J. H. A1 - Minelli, C. A1 - Araujo, J. R. A1 - Bock, B. A1 - Brüner, P. A1 - Castner, D. G. A1 - Ceccone, G. A1 - Counsell, J. D. P. A1 - Dietrich, Paul M. A1 - Engelhardt, M. H. A1 - Fearn, S. A1 - Galhardo, C. E. A1 - Kalbe, H. A1 - Kim, J. W. A1 - Lartundo-Rojas, L. A1 - Luftman, H. S. A1 - Nunney, T. S. A1 - Pseiner, J. A1 - Smith, E. F. A1 - Spampinato, V. A1 - Sturm, J. M. A1 - Thomas, A. G. A1 - Treacy, J. P. W. A1 - Veith, L. A1 - Wagstaffe, M. A1 - Wang, H. A1 - Wang, M. A1 - Wang, Y.-C. A1 - Werner, W. A1 - Yang, L. A1 - Shard, A. G. T1 - Versailles Project on Advanced Materials and Standards Interlaboratory Study on Measuring the Thickness and Chemistry of Nanoparticle Coatings Using XPS and LEIS JF - The Journal of Physical Chemistry C N2 - We report the results of a Versailles Project on Advanced Materials and Standards (VAMAS) interlaboratory study on the measurement of the shell thickness and chemistry of nanoparticle coatings. Peptide-coated gold particles were supplied to laboratories in two forms: a colloidal suspension in pure water and particles dried onto a silicon wafer. Participants prepared and analyzed these samples using either X-ray photoelectron spectroscopy (XPS) or low energy ion scattering (LEIS). Careful data analysis revealed some significant sources of discrepancy, particularly for XPS. Degradation during transportation, storage, or sample preparation resulted in a variability in thickness of 53%. The calculation method chosen by XPS participants contributed a variability of 67%. However, variability of 12% was achieved for the samples deposited using a single method and by choosing photoelectron peaks that were not adversely affected by instrumental transmission effects. The study identified a need for more consistency in instrumental transmission functions and relative sensitivity factors since this contributed a variability of 33%. The results from the LEIS participants were more consistent, with variability of less than 10% in thickness, and this is mostly due to a common method of data analysis. The calculation was performed using a model developed for uniform, flat films, and some participants employed a correction factor to account for the sample geometry, which appears warranted based upon a simulation of LEIS data from one of the participants and comparison to the XPS results. KW - VAMAS KW - Interlaboratory Study KW - Nanoparticle coating KW - XPS KW - LEIS KW - shell thicknss and chemistry PY - 2016 UR - http://pubs.acs.org/doi/pdf/10.1021/acs.jpcc.6b06713 DO - https://doi.org/10.1021/acs.jpcc.6b06713 IS - 120 SP - 24070 EP - 24079 PB - ACS Publications AN - OPUS4-38428 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Solberg, S. B. B. A1 - Zimmermann, P. A1 - Wilhelmsen, Ø. A1 - Bock, Robert A1 - Burheim, O. S. T1 - Analytical treatment of ion-exchange permselectivity and transport number measurements for high accuracy JF - Journal of Membrane Science N2 - We analyse electromotive force measurements of concentration cells using non-equilibrium thermodynamics, and determine the transference coefficients of ion-exchange membranes in aqueous KCl solutions. By taking advantage of the analytical expression for the permselectivity, we extract transport coefficients with high accuracy. The transport number of K+ and the transference coefficient of water in the Selemion CMVN cationexchange membrane are found to be 100𝑡K+ = 99.59 ± 0.56 and 𝑡𝑤 = 3.69 ± 0.40 respectively, while for the Selemion AMVN anion-exchange membrane they are 100𝑡Cl− = 100.21 ± 0.37 and 𝑡𝑤 = −3.75 ± 0.27. These results suggest that the membranes are perfectly selective to the target ion, and that each ion carries 3-4 water molecules through the membrane, which reduces the membrane permselectivity. In these concentration cells, the electrical potential contribution of the membrane alone was more easily isolated with bare Ag/AgCl electrodes without reference solutions and liquid junction plugs. Additionally, we find a large contribution to the measured concentration cell voltage from concentration gradients across the porous plug of the reference electrode, which cannot be explained by Henderson’s equation alone. For most of the concentration range, the transport number of the porous plug is determined to be 100𝑡K+ = 49.43 ± 0.78 with negligible water transport, similar to literature values for bulk electrolyte. In dilute electrolyte solutions with concentrations below 0.1 mol kg−1, the plug shows anomalous behaviour consistent with an increase in K+ selectivity and water co-transport. KW - Ion-exchange membranes KW - Electrodialysis KW - Non-equilibrium thermodynamics KW - Electroosmosis KW - Transport number PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-580654 DO - https://doi.org/10.1016/j.memsci.2023.121904 SN - 1873-3123 VL - 2023 IS - 685 PB - Elsevier CY - New York, NY [u.a.] AN - OPUS4-58065 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Osterloh, Kurt A1 - Bücherl, T. A1 - Lierse von Gostomski, C. A1 - Zscherpel, Uwe A1 - Ewert, Uwe A1 - Bock, S. T1 - Filtering algorithm for dotted interferences JF - Nuclear instruments and methods in physics research A N2 - An algorithm has been developed to remove reliably dotted interferences impairing the perceptibility of objects within a radiographic image. This particularly is a major challenge encountered with neutron radiographs collected at the NECTAR facility, Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II): the resulting images are dominated by features resembling a snow flurry. These artefacts are caused by scattered neutrons, gamma radiation, cosmic radiation, etc. all hitting the detector CCD directly in spite of a sophisticated shielding. This makes such images rather useless for further direct evaluations. One approach to resolve this problem of these random effects would be to collect a vast number of single images, to combine them appropriately and to process them with common image filtering procedures. However, it has been shown that, e.g. median filtering, depending on the kernel size in the plane and/or the number of single shots to be combined, is either insufficient or tends to blur sharp lined structures. This inevitably makes a visually controlled processing image by image unavoidable. Particularly in tomographic studies, it would be by far too tedious to treat each single projection by this way. Alternatively, it would be not only more comfortable but also in many cases the only reasonable approach to filter a stack of images in a batch procedure to get rid of the disturbing interferences. The algorithm presented here meets all these requirements. It reliably frees the images from the snowy pattern described above without the loss of fine structures and without a general blurring of the image. It consists of an iterative, within a batch procedure parameter free filtering algorithm aiming to eliminate the often complex interfering artefacts while leaving the original information untouched as far as possible. KW - Neutron KW - Radiography KW - Tomography KW - Filtering KW - Evaluation KW - NECTAR PY - 2011 DO - https://doi.org/10.1016/j.nima.2011.01.107 SN - 0168-9002 SN - 0167-5087 VL - 651 IS - 1 SP - 171 EP - 174 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-24917 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Solberg, S. A1 - Zimmermann, P. A1 - Wilhelmsen, Ø. A1 - Lamb, J. A1 - Bock, Robert A1 - Burheim, O. T1 - Heat to Hydrogen by Reverse Electrodialysis—Using a Non-Equilibrium Thermodynamics Model to Evaluate Hydrogen Production Concepts Utilising Waste Heat JF - Energies N2 - The reverse electrodialysis heat engine (REDHE) is a promising salinity gradient energy technology, capable of producing hydrogen with an input of waste heat at temperatures below 100 °C. A salinity gradient drives water electrolysis in the reverse electrodialysis (RED) cell, and spent solutions are regenerated using waste heat in a precipitation or evaporation unit. This work presents a non-equilibrium thermodynamics model for the RED cell, and the hydrogen production is investigated for KCl/water solutions. The results show that the evaporation concept requires 40 times less waste heat and produces three times more hydrogen than the precipitation concept. With commercial evaporation technology, a system efficiency of 2% is obtained, with a hydrogen production rate of 0.38 gH2 m−2h−1 and a waste heat requirement of 1.7 kWh g−1H2. The water transference coefficient and the salt diffusion coefficient are identified as membrane properties with a large negative impact on hydrogen production and system efficiency. Each unit of the water transference coefficient in the range tw=[0–10] causes a −7 mV decrease in unit cell electric potential, and a −0.3% decrease in system efficiency. Increasing the membrane salt diffusion coefficient from 10−12 to 10−11 leads to the system efficiency decreasing from 2% to 0.6% KW - Non-equilibrium thermodynamics KW - Hydrogen KW - Waste heat KW - RED PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-556677 DO - https://doi.org/10.3390/en15166011 VL - 15 IS - 16 SP - 6011 PB - MDPI AN - OPUS4-55667 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Sauermoser-Yri, M. A1 - Veldurthi, N. A1 - Wölfle, C. H. A1 - Svartvatn, P. J. A1 - Flo Hoem, S. O. A1 - Lid, M. J. A1 - Bock, Robert A1 - Palko, J. A1 - Torgersen, J. T1 - On the porosity-dependent permeability and conductivity of triply periodic minimal surface based porous media JF - Journal of Materials Research and Technology N2 - With the fast development in the field of additive manufacturing, triply periodic minimal surface (TPMS) based porous media have recently found many uses in mechanical property tuning. However, there is still a lack of understanding in their porosity-dependent permeability and electrical as well as thermal conductivity. Here, we perform finite volume simulations on the solid and void domains of the Schoen gyroid (SG), Schwarz primitive (SP) and Schwarz primitive beam (SPB) TPMS with porosities between 63% and 88% in Ansys Fluent. A simple cubic lattice (CL) of equivalent porosity served as reference. The SPB and CL showed up to one order of magnitude higher permeabilities than the SG and SP. However, SG and SP have about 1.3 and 2.6 times the electrical and thermal conductivity of SPB and CL, respectively. Furthermore, the properties of SPB and CL are largely affected by the surface area density, whereas tortuosity variation does not impact permeability and conductivity to a major extent. Finally, empirical relations are adapted to describe the presented data and thus, they may enable future designers of TPMS based porous structures to fine-tune the geometries according to the requirements on permeability and electrical as well as thermal conductivity. KW - Metals and Alloys KW - Surfaces, Coatings and Films KW - Biomaterials KW - Ceramics and Composites PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-585250 DO - https://doi.org/10.1016/j.jmrt.2023.09.242 SN - 2238-7854 VL - 27 SP - 585 EP - 599 PB - Elsevier B.V. AN - OPUS4-58525 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reed, B. P. A1 - Cant, D.J.H. A1 - Spencer, S.J. A1 - Carmona-Carmona, A. J. A1 - Bushell, A. A1 - Herrara-Gómez, A. A1 - Kurokawa, A. A1 - Thissen, A. A1 - Thomas, A.G. A1 - Britton, A.J. A1 - Bernasik, A. A1 - Fuchs, A. A1 - Baddorf, A.P. A1 - Bock, B. A1 - Thellacker, B. A1 - Cheng, B. A1 - Castner, D.G. A1 - Morgan, D.J. A1 - Valley, D. A1 - Willneff, E.A. A1 - Smith, E.P. A1 - Nolot, E. A1 - Xie, F. A1 - Zorn, G. A1 - Smith, G.C. A1 - Yasukufu, H. A1 - Fenton, J.L. A1 - Chen, J. A1 - Counsell, J.D.P. A1 - Radnik, Jörg A1 - Gaskell, K.J. A1 - Artyushkova, K. A1 - Yang, L. A1 - Zhang, L. A1 - Eguchi, M. A1 - Walker, M. A1 - Hajdyla, M. A1 - Marzec, M.M. A1 - Linford, M.R. A1 - Kubota, N. A1 - Cortazar-Martinez, O. A1 - Dietrich, P. A1 - Satoh, R. A1 - Schroeder, S.L.M. A1 - Avval, T.G. A1 - Nagatomi, T. A1 - Fernandez, V. A1 - Lake, W. A1 - Azuma, Y. A1 - Yoshikawa, Y. A1 - Compean-Gonzalez, C.L. A1 - Ceccone, G. A1 - Shard, A.G. T1 - ERRATUM: “Versailles project on advanced materials and standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene” [J. Vac. Sci. Technol. A 38, 063208 (2020)] JF - Journal of Vacuum Science & Technology A N2 - The lead authors failed to name two collaborators as co-authors. The authors listed should include: Miss Claudia L. Compean-Gonzalez (ORCID: 0000-0002-2367-8450) and Dr. Giacomo Ceccone (ORCID: 0000-0003-4637-0771). These co-authors participated in VAMAS project A27, provided data that were analyzed and presented in this publication (and supporting information), and reviewed the manuscript before submission. KW - X-ray photoelectron spectroscopy KW - Transmission function KW - Low-density polyethylene PY - 2021 DO - https://doi.org/10.1116/6.0000907 VL - 39 IS - 2 SP - 027001 PB - American Vacuum Society AN - OPUS4-52380 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reed, B. P. A1 - Cant, D.J.H. A1 - Spencer, J. A1 - Carmona-Carmona, A. J. A1 - Bushell, A. A1 - Herrara-Gómez, A. A1 - Kurokawa, A. A1 - Thissen, A. A1 - Thomas, A.G. A1 - Britton, A.J. A1 - Bernasik, A. A1 - Fuchs, A. A1 - Baddorf, A. P. A1 - Bock, B. A1 - Thellacker, B. A1 - Cheng, B. A1 - Castner, D.G. A1 - Morgan, D.J. A1 - Valley, D. A1 - Willneff, E.A. A1 - Smith, E.F. A1 - Nolot, E. A1 - Xie, F. A1 - Zorn, G. A1 - Smith, G.C. A1 - Yasukufu, H. A1 - Fenton, J. L. A1 - Chen, J. A1 - Counsell, J..D.P. A1 - Radnik, Jörg A1 - Gaskell, K.J. A1 - Artyushkova, K. A1 - Yang, L. A1 - Zhang, L. A1 - Eguchi, M. A1 - Walker, M. A1 - Hajdyla, M. A1 - Marzec, M.M. A1 - Linford, M.R. A1 - Kubota, N. A1 - Cartazar-Martínez, O. A1 - Dietrich, P. A1 - Satoh, R. A1 - Schroeder, S.L.M. A1 - Avval, T.G. A1 - Nagatomi, T. A1 - Fernandez, V. A1 - Lake, W. A1 - Azuma, Y. A1 - Yoshikawa, Y. A1 - Shard, A.G. T1 - Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene JF - Journal of Vacuum Science & Technology A N2 - We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ∼3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ∼5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ∼4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. We also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration. KW - X-ray photoelectron spectroscopy KW - Transmission function KW - Intensity scale calibration KW - Reference spectra KW - Low-density polyethylene (LDPE) PY - 2020 DO - https://doi.org/10.1116/6.0000577 VL - 38 IS - 6 SP - 063208 AN - OPUS4-51655 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -