TY - CONF A1 - Knabe, C. A1 - Gildenhaar, Renate A1 - Berger, R. A1 - Ostapowicz, W. A1 - Fitzner, R. A1 - Radlanski, R. A1 - Gross, U. A1 - Siebert, G. T1 - In vitro examination of novel calcium phosphates using osteogenic cultures T2 - Programme and transactions of the Fifth World Biomaterials Congress T2 - 5th World Biomaterials Congress CY - Toronto, Canada DA - 1996-05-29 KW - In-vitro Untersuchung KW - Kalzium-Phosphat KW - Zahnersatz KW - Knochen PY - 1996 VL - 1 SP - 890 CY - Toronto AN - OPUS4-672 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ploska, Ute A1 - Kraus, Werner A1 - Berger, W. A1 - Lugscheider, E. A1 - Nyland, A. T1 - Calcium phosphate-containing materials in the system cati4(PO4)6-CaZr4(PO4)6 for using as coatings on titanium substrates JF - Bioceramics KW - Calciumphosphat KW - Beschichtung KW - Titanträgermaterial PY - 1996 VL - 9 SP - 353 EP - 356 AN - OPUS4-1333 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gildenhaar, Renate A1 - Berger, Georg A1 - Bernstein, A. A1 - Hein, W. T1 - In-Vitro Surface Reactions of Plasma Sprayed Bioceramics JF - Biomaterialien T2 - International Symposium "Interface Biology of Implants" CY - Rostock, Germany DA - 2003-05-15 PY - 2003 SN - 1616-0177 SN - 0011-8656 VL - 4 IS - 2 SP - 106 PB - Verl. Neuer Merkur CY - München AN - OPUS4-2595 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gildenhaar, Renate A1 - Bernstein, A. A1 - Berger, Georg A1 - Hein, W. T1 - In-vitro Surface Reactions of Bioceramic Materials JF - Key engineering materials KW - Ceramics KW - Coating KW - Biomaterial KW - Bone KW - Biocompatibility KW - Surface reaction PY - 2004 SN - 1013-9826 VL - 254-256 SP - 407 EP - 410 PB - Trans Tech Publ. CY - Aedermannsdorf AN - OPUS4-2749 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bernstein, A. A1 - Brandt, J. A1 - Gildenhaar, Renate A1 - Berger, Georg A1 - Hein, W. T1 - The Bone Reaction to Ceramic Coated Pins - Animal Study JF - Key engineering materials KW - Biocompatibility KW - Biomaterial KW - Bone KW - Ceramics KW - Coating KW - Surface Reaction KW - Biokeramik KW - Beschichtung KW - Knochenersatz KW - Biomompatibilität PY - 2005 SN - 1013-9826 VL - 284-286 SP - 179 EP - 182 PB - Trans Tech Publ. CY - Aedermannsdorf AN - OPUS4-5495 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Berger, Wolfgang A1 - Kalbe, Ute A1 - Krüger, Oliver A1 - Hennecke, D. A1 - Kördel, W. T1 - Evaluierung von Elutionsmethoden - Durchführung von Robustheitsuntersuchungen zur Validierung von E DIN 19527 für ausgewählte Böden und Bodenmaterialien mit prioritären organischen Schadstoffen T2 - UBA-Texte N2 - Ziel des Vorhabens ist es, die Robustheit des Schüttelverfahrens nach E DIN 19527 mit einem Wasser-/Feststoffverhältnis von 2 l/kg für unterschiedliche Bodenarten und Bodenmaterialien zu überprüfen. Gleichzeitig soll bei diesen Untersuchungen das Stoffspektrum auf weitere prioritäre organische Kontaminanten erweitert werden. Dies stellt die Voraussetzung für die Durchführung von Ringversuchen zur Validierung der Norm DIN 19527 dar. KW - Kontaminierter Boden KW - PAK KW - PCB KW - MKW KW - Phenole KW - Elutionsverfahren KW - Schütteltests KW - Robustheitsuntersuchungen KW - Standardisierung KW - Validierung KW - Laborvergleich PY - 2013 UR - https://www.umweltbundesamt.de/sites/default/files/medien/378/publikationen/texte_77_2013_robustheitsuntersuchung_terytze_0.pdf VL - 77 SP - 1 EP - 124 PB - Umweltbundesamt CY - Dessau-Roßlau AN - OPUS4-28990 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dombrowski, Felix A1 - Garcia Caso, P.W. A1 - Laschke, M.W. A1 - Klein, M. A1 - Günster, Jens A1 - Berger, Georg T1 - 3-D printed bioactive bone replacement scaffolds of alkaline substituted ortho-phosphates containing meta- and di-phosphates JF - Key engineering materials KW - Calcium alkaline phosphates KW - 3-D printing KW - Porosity KW - Compressive strength PY - 2013 DO - https://doi.org/10.4028/www.scientific.net/KEM.529-530.138 SN - 1013-9826 VL - 529-530 SP - 138 EP - 142 PB - Trans Tech Publ. CY - Aedermannsdorf AN - OPUS4-26972 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wolff, Timo A1 - Mantouvalou, I. A1 - Malzer, W. A1 - Nissen, J. A1 - Berger, D. A1 - Zizak, I. A1 - Sokaras, D. A1 - Karydas, A. A1 - Grlj, N. A1 - Pelicon, P. A1 - Schütz, R. A1 - Zitniki, M. A1 - Kanngießer, B. T1 - Performance of a polycapillary halflens as focussing and collecting optic - a comparison JF - Journal of analytical atomic spectrometry N2 - Polycapillary halflenses are widely used to focus X-ray radiation onto a small spot. Additionally they can reduce the field of view of a semiconductor detector when placed in front of one. In 3D micro X-ray fluorescence spectroscopy (3D Micro-XRF) with synchrotron radiation, two polycapillary halflenses are used in a confocal geometry. Up until now, characterization measurements in the focal plane have only been performed in the case of the lens focusing parallel radiation. Assumptions have been made, that in the other case, when isotropic radiation from a spot source is transported to a detector, the acceptance distribution in the focal plane is also Gaussian. We performed measurements with an electron beam as well as a proton beam which confirm this assumption. In addition, a comparison between measurements in collecting and focusing mode show differences in spot size and transmission. These differences exemplify the fact that there is not one global spot size or transmission function of a polycapillary halflens. Illumination and divergence effects can alter both characteristic lens parameters. PY - 2009 DO - https://doi.org/10.1039/b817828c SN - 0267-9477 SN - 1364-5544 VL - 24 SP - 669 EP - 675 PB - Royal Society of Chemistry CY - London AN - OPUS4-19415 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Ecker, K. H. A1 - Wätjen, U. A1 - Berger, Achim A1 - Grötzschel, R. A1 - Persson, L. A1 - Pritzkow, W. A1 - Radtke, Martin A1 - Riebe, Gundel A1 - Riesemeier, Heinrich A1 - Vogl, Jochen T1 - Certification of antimony implanted in silicon wafer with a silicon dioxide diffusion barrier - IRMM-302 and BAM-L001 T2 - IRMM and BAM Information Reference Materials N2 - This Report describes the certification of the reference material antimony implanted in Si/SiO2 intended to be used for calibration of surface and near surface analytical methods. It describes the preparation, homogeneity measurements and the analytical work performed for the certification of both Areal density of antimony Atoms (retained dose) and the isotope amount Ratio as well as giving considerations on the stability of the material. KW - Isotope ratio KW - Areal density KW - Surface analysis PY - 2002 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-355752 SP - 1 EP - 40 PB - Institute for Reference Materials and Measurements CY - Geel, Belgium AN - OPUS4-35575 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Braun, Ulrike A1 - Lorenz, Edelgard A1 - Weimann, Christiane A1 - Sturm, Heinz A1 - Karimov, I. A1 - Ettl, J. A1 - Meier, R. A1 - Wohlgemuth, W. A. A1 - Berger, H. A1 - Wildgruber, M. T1 - Mechanic and surface properties of central-venous port catheters after removal: A comparison of polyurethane and Silicon rubber materials JF - Journal of the Mechanical Behavior of Biomedical Materials N2 - Central venous port devices made of two different polymeric materials, thermoplastic polyurethane (TPU)and silicone rubber (SiR), were compared due their material properties. Both naïve catheters as well as catheters after removal from patients were investigated. In lab experiments the influence of various chemo-therapeutic solutions on material properties was investigated, where as the samples after removal were compared according to the implanted time inpatient. The macroscopic,mechanical performance was assessed with dynamic, specially adapted tests for elasticity. The degradation status of the materials was determined with common tools of polymer characterisation, such as infrared spectroscopy, molecular weight measurements and various methods of thermal analysis. The surface morphology was an alysed using scanning electron microscopy. A correlation between material properties and clinical performance was proposed. The surface morphology and chemical composition of the polyurethane catheter materials can potentially result in increased susceptibility of the catheter to bloodstream infections and thrombotic complications. The higher mechanic failure,especially with increasing implantation time of the silicone catheters is related to the lower mechanical performance compared to the polyurethane material as well as loss of barium sulphate filler particles near the surface of the catheter. This results in preformed microscopic notches, which act as predetermined sites of fracture. KW - Thermoplastic polyurethane (TPU) KW - Silicone rubber (SiR) KW - Catheters KW - Central venous access port KW - Complication KW - Structure propertyrelationship KW - Mechanical testing PY - 2016 DO - https://doi.org/10.1016/j.jmbbm.2016.08.002 SN - 1751-6161 SN - 1878-0180 VL - 64 SP - 281 EP - 291 PB - Elsevier Ltd. AN - OPUS4-37178 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müeller, W.-D. A1 - Gross, U. A1 - Fritz, Th. A1 - Voigt, Ch. A1 - Fischer, P. A1 - Berger, Georg A1 - Rogaschewski, S. A1 - Lange, K.-P. T1 - Evaluation of the interface between bone and titanium surfaces being blasted by aluminium oxide or bioceramic particles JF - Clinical oral implants research N2 - The surface structure, in particular the surface roughness, and the surface chemistry of titanium implants influence their anchoring in bone. The aim of this study was to analyse metal-bone contact (MBC) after modification of the implant surface, using different materials for blasting. The surface modification of titanium was produced by blasting it with particles made of Al2O3 or bioceramics. The biological effects were then investigated experimentally using 27 rabbits, analysed after 7, 28 and 84 days after the implantation of titanium cylinders treated accordingly. The MBC showed a tendency for more bone after bioceramics were used as a blasting material, compared to Al2O3. KW - Dental implants KW - Surface modification KW - Animal experiment KW - Bioceramics PY - 2003 DO - https://doi.org/10.1034/j.1600-0501.2003.00791.x SN - 0905-7161 SN - 1600-0501 VL - 14 IS - 3 SP - 349 EP - 356 PB - Blackwell Munksgaard CY - Oxford AN - OPUS4-3506 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ma, L. A1 - Feng, L. A1 - Hioki, A. A1 - Cho, K.H. A1 - Vogl, Jochen A1 - Berger, Achim A1 - Turk, G. A1 - Macleod, S. A1 - Labarraque, G. A1 - Tong, W.F. A1 - Schiel, D. A1 - Yafa, C. A1 - Valiente, L. A1 - Konopelko, L.A. A1 - Quetel, C. A1 - Vermaercke, P. A1 - Manzano, J.V.L. A1 - Linsky, M. A1 - Cortés, E. A1 - Tangpitayakul, S. A1 - Plangsangmas, L. A1 - Bergamaschi, L. A1 - Hearn, R. T1 - International comparison of the determination of the mass fraction of cadmium, chromium, mercury and lead in polypropylene: the Comité Consultatif pour la quantité de matière pilot study CCQM-P106 JF - Accreditation and quality assurance KW - Cadmium KW - Chromium KW - Mercury KW - Lead KW - Polypropylene KW - CCQM PY - 2010 DO - https://doi.org/10.1007/s00769-009-0574-z SN - 0949-1775 SN - 1432-0517 VL - 15 IS - 1 SP - 39 EP - 44 PB - Springer CY - Berlin AN - OPUS4-20787 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Arndt, R.W. A1 - Grosse, C.U, A1 - Maehner, D. A1 - Niederleithinger, Ernst A1 - Taffe, A. A1 - Algernon, D. A1 - Berger, J. A1 - Kessler, S. A1 - Krueger, M. A1 - Kruschwitz, Sabine A1 - Ufermann-Wallmeier, D. A1 - Walther, A. T1 - Non-destructive testing in civil engineering: A memorandum for teaching at German-speaking universities T2 - Proceedings of NDT-CE 2022 N2 - This contribution summarizes actual developments and draft fundamental teaching topics in the field of nondestructive testing in civil engineering (NDT-CE). It is based on the first memorandum on teaching and research in the field of NDT-CE at German speaking universities and provides an overview of the academic education and highlights possible focuses, especially in teaching but also takes into account noteworthy developments and topics in research in the field of NDT-CE. Suggestions are given for the development and advancement of the teaching curricula in regards to a comprehensive and sound professional education of students in civil engineering and adjacent disciplines. T2 - NDT-CE 2022 CY - Zurich, Switzerland DA - 16.08.2022 KW - Curriculum KW - NDT-CE KW - University KW - Competencies PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-563269 UR - https://www.ndt.net/article/ndtce2022/paper/61547_manuscript.pdf SP - 1 EP - 10 PB - NDT.net AN - OPUS4-56326 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -