TY - JOUR A1 - Neuschaefer-Rube, U. A1 - Illemann, J. A1 - Sturm, M. A1 - Bircher, B. A1 - Meli, F. A1 - Bellon, Carsten A1 - Evsevleev, Sergei T1 - Validation of a fast and traceable radiographic scale calibration of dimensional computed tomography N2 - A fast and highly precise method of determining the geometrical scale factor of computed tomography (CT) measurements has been validated successfully by Bundesanstalt für Materialforschung und -prüfung (BAM), the Federal Institute of Metrology (METAS) and Physikalisch-Technische Bundesanstalt (PTB) within the scope of AdvanCT (Advanced Computed Tomography for dimensional and surface measurements in industry), a project funded in the European Metrology Programme for Innovation and Research (EMPIR). The method has been developed by PTB and requires only two radiographic images of a calibrated thin 2D standard (hole grid standard) from two opposite directions. The mean grid distance is determined from both radiographs. From this and with the help of the calibration result, the radiographic scale and therefore the voxel size is determined. The procedure takes only a few minutes and avoids a time-consuming CT scan. To validate the method, the voxel sizes determined via this method were compared with voxel sizes determined from CT scans of calibrated objects. Relative deviations between the voxel sizes in the range of 10−5 were achieved with minimal effort using cone-beam CT systems at moderate magnifications. KW - Dimensional metrology KW - Voxel size KW - Industrial CT KW - Geometrical magnification PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-553271 DO - https://doi.org/10.1088/1361-6501/ac74a3 SN - 0957-0233 VL - 33 IS - 9 SP - 1 EP - 9 PB - IOP Publishing CY - Bristol, UK AN - OPUS4-55327 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Wieder, Frank A1 - Ewert, Uwe A1 - Vogel, Justus A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten T1 - A Novel Multi Slit X-Ray Backscatter Camera Based on Synthetic Aperture Focusing N2 - A special slit collimator was developed earlier for fast acquisition of X-ray back scatter images. The design was based on a twisted slit design (ruled surfaces) in a Tungsten block to acquire backscatter images. The comparison with alternative techniques as flying spot and coded aperture pin hole technique could not prove the expected higher contrast sensitivity. In analogy to the coded aperture technique, a novel multi slit camera was designed and tested. Several twisted slits were parallelly arranged in a metal block. The CAD design of different multi-slit cameras was evaluated and optimized by the computer simulation packages aRTist and McRay. The camera projects a set of equal images, one per slit, to the digital detector array, which are overlaying each other. Afterwards, the aperture is corrected based on a deconvolution algorithm to focus the overlaying projections into a single representation of the object. Furthermore, a correction of the geometrical distortions due to the slit geometry is performed. The expected increase of the contrast-to-noise ratio is proportional to the square root of the number of parallel slits in the camera. However, additional noise has to be considered originating from the deconvolution operation. The slit design, functional principle, and the expected limits of this technique are discussed. T2 - 43rd Annual Review of Progress in QNDE CY - Atlanta, GA, USA DA - 17.07.2016 KW - Deconvolution KW - Back scatter imaging KW - Computer simulation KW - Aperture focusing PY - 2017 SN - 978-0-7354-1474-7 DO - https://doi.org/10.1063/1.4974711 VL - 1806 SP - 1 EP - 9 PB - AIP Publishing AN - OPUS4-42429 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zhukovskiy, M. A1 - Podoliako, S. A1 - Tillack, G.-R. A1 - Bellon, Carsten ED - Thompson, D. O. T1 - Monte Carlo Simulation of Photon Transport Coupled to CAD Object Description T2 - 30th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Green Bay, WI, USA DA - 2003-07-27 KW - Monte-Carlo-Simulation KW - Radiographie PY - 2004 SN - 0-7354-0173-X SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings IS - 700 SP - 515 EP - 521 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-5055 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Bellon, Carsten A1 - Jaenisch, Gerd-Rüdiger T1 - Computer simulation of X-Ray NDE process T2 - International Symposium on Computed Tomography and Image Processing for Industrial Radiology CY - Berlin, Germany DA - 2003-06-23 KW - Computersimulation KW - Radiografie KW - CAD PY - 2003 SN - 3-931381-48-X N1 - Geburtsname von Jaenisch, Gerd-Rüdiger: Tillack, G.-R. - Birth name of Jaenisch, Gerd-Rüdiger: Tillack, G.-R. N1 - Serientitel: DGZfP-Proceedings BB – Series title: DGZfP-Proceedings BB IS - 84-CD SP - 187 EP - 189 PB - DGZfP CY - Berlin AN - OPUS4-2872 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Zagonov, V. P. A1 - Zukhovsky, M. E. A1 - Podolyako, S.V. A1 - Skachkov, M.V. T1 - Boundary Description Approach Application for Modeling the X-Ray Transformation in Computational Diagnostics Problems KW - Radiographie KW - Modellierung KW - Oberflächenmodelle KW - CAD KW - Monte Carlo Modell PY - 2004 SN - 1048-5082 VL - 16 IS - 5 SP - 103 EP - 116 PB - Birkhäuser CY - Boston, Mass. AN - OPUS4-4592 LA - rus AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - Monte-Carlo-Simulation der Strahlenausbreitung an realen Bauteilgeometrien T2 - DGZfP-Jahrestagung 2004: ZfP in Forschung, Entwicklung und Anwendung CY - Salzburg, Austria DA - 2004-05-17 PY - 2004 AN - OPUS4-5597 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - Computer Simulation of X-ray NDE Process T2 - International Symposium on Computed Tomography and Image Processing for Industrial Radiology CY - Berlin, Germany DA - 2003-06-23 PY - 2003 AN - OPUS4-4418 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten T1 - Monte Carlo Simulation für radiographische Anwendungen PY - 2003 SN - 0025-5300 N1 - Geburtsname von Jaenisch, Gerd-Rüdiger: Tillack, G.-R. - Birth name of Jaenisch, Gerd-Rüdiger: Tillack, G.-R. VL - 45 IS - 3 SP - 85 EP - 91 PB - Carl Hanser Verlag CY - München AN - OPUS4-1995 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Zhukovskiy, M. A1 - Podoliako, S. T1 - Monte-Carlo-Simulation und CAD KW - Prozeßtomographie KW - Rekonstruktionsalgorithmen KW - Markov-Felder KW - Statistische Estimationstheorie KW - Kalman-Filter PY - 2005 DO - https://doi.org/10.3139/120.100650 SN - 0025-5300 VL - 47 IS - 4 SP - 210 EP - 218 PB - Carl Hanser Verlag CY - München AN - OPUS4-11605 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Bellon, Carsten A1 - Jaenisch, Gerd-Rüdiger T1 - Durchstrahlungsprüfung am Computer simuliert T2 - DGZfP-Jahrestagung 2005 CY - Rostock, Deutschland DA - 2005-05-02 KW - Radiographie KW - Computer-Simulation PY - 2005 SN - 3-931381-64-1 N1 - Serientitel: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. – Series title: Berichtsband / Deutsche Gesellschaft für zerstörungsfreie Prüfung e. V. IS - 94-CD SP - 1 EP - 4(?) PB - DGZfP CY - Berlin AN - OPUS4-11590 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - Durchstralungsprüfung am Computer simuliert T2 - DGZfP-Jahrestagung 2005 CY - Rostock, Germany DA - 2005-05-03 PY - 2005 AN - OPUS4-11438 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - Durchstrahlungsprüfung am Computer simuliert T2 - 12. Sommerkurs Werkstofftechnik, Otto-von-Guericke-Universität CY - Magdeburg, Germany DA - 2004-09-03 PY - 2004 AN - OPUS4-5598 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zhukovskiy, M. A1 - Podoliako, Serguei A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten T1 - Numerical Simulation of X-Ray Scattering Processes during Radiographic Inspection of Materials N2 - Abstract A technique for numerical simulation of the processes of forming X-ray radiography images of complex multicomponent objects with allowance for the penetrating-radiation absorption and scattering processes is proposed. The technique proposed is based on an efficient description of complex 3D objects with piecewise-homogeneous structures and uses precisely specified shells separating homogeneous components of an object. Being combined with a developed version of the Monte Carlo method, this approach yields an efficient computational apparatus for analyzing the regularities of the formation of radiographic images of objects’ internal structures. This apparatus is intended for state-of-the-art multiprocessor computing systems. Having been obtained via the technique developed, the results of the numerical analysis of the effect of different mechanisms of interaction between photons and matter (including coherent and incoherent scattering with allowance for bonds of electrons in atoms) on the formed radiographic image of the object’s internal structure are discussed. The advantage of the described technique over the known MCNP program complex is shown. KW - Monte Carlo Verfahren KW - CAD KW - Radiographie PY - 2006 DO - https://doi.org/10.1134/S1061830906060052 SN - 1061-8309 SN - 1608-3385 VL - 42 IS - 6 SP - 382 EP - 391 PB - MAIK Nauka/Interperiodica Publ. CY - Moscow AN - OPUS4-13798 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zhukovskiy, M. A1 - Podoliako, S. A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Samadurau, Uladzimir ED - Thompson, D. T1 - Monte Carlo Simulation Tool with CAD Interface T2 - 32th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Brunswick, ME, USA DA - 2005-07-31 KW - Monte Carlo Simulation KW - Radiography KW - CAD PY - 2006 SN - 0-7354-0312-0 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings IS - 820 SP - 574 EP - 581 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-12436 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Samadurau, Uladzimir A1 - Zhukovskiy, M. A1 - Podoliako, Serguei T1 - McRay - A Monte Carlo Model Coupled to CAD for Radiation Techniques T2 - 9th European Conference on NDT CY - Berlin, Germany DA - 2006-09-25 KW - Monte Carlo Verfahren KW - CAD KW - Radiographie PY - 2006 SN - 3-931381-86-2 SP - 1(?) EP - 8(?) PB - European Federation for Non-Destructive Testing CY - Berlin AN - OPUS4-13796 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Samadurau, Uladzimir T1 - Are Monte Carlo models applicable to radiological techniques? T2 - National Seminar on NDE of the Indian Society for Non-Destructive Testing CY - Kolkata, India DA - 2005-12-02 KW - Radiation techniques KW - Scattered radiation KW - Monte Carlo simulation KW - CAD PY - 2005 SP - 11 pages PB - Indian Society for Non-Destructive Testing CY - Kalkutta AN - OPUS4-11835 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Ewert, Uwe T1 - Simulation for high energy radiography and reliability assessment T2 - National Seminar on NDE of the Indian Society for Non-Destructive Testing CY - Kolkata, India DA - 2005-12-02 KW - Radiation techniques KW - Simulation KW - High-energy radiography KW - CAD PY - 2005 SP - 14 pages PB - Indian Society for Non-Destructive Testing CY - Kalkutta AN - OPUS4-11834 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Samadurau, Uladzimir A1 - Zhukovskiy, M. A1 - Podoliako, Serguei T1 - Monte Carlo radiographic model with CAD-based geometry description KW - Monte Carlo Verfahren KW - CAD KW - Radiographie PY - 2006 SN - 0007-1137 VL - 48 IS - 10 SP - 618 EP - 623 PB - British Institute of Non-Destructive Testing CY - Northampton AN - OPUS4-13795 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Christina A1 - Elagin, Mstislav A1 - Bellon, Carsten A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Rosenthal, Martina A1 - Redmer, Bernhard A1 - Ryden, H. A1 - Ronneteg, U. ED - Proske, D. T1 - Probability-of-Detection-Evaluation of NDT Techniques for Cu-Canisters for Risk Assessment of Nuclear Waste Encapsulation T2 - 4th International Probabilistic Symposium CY - Berlin, Germany DA - 2006-10-12 KW - Zerstörungsfreie Prüfung KW - Zuverlässigkeit KW - POD KW - Endlagerung radioaktiver Abfälle PY - 2006 SN - 3-00-019232-8 N1 - Geburtsname von Rosenthal, Martina: Scharmach, M. - Birth name of Rosenthal, Martina: Scharmach, M. SP - 227 EP - 252 PB - Bundesanstalt für Materialforschung und -prüfung CY - Berlin AN - OPUS4-14418 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Christina A1 - Elagin, Mstislav A1 - Bellon, Carsten A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Rosenthal, Martina A1 - Redmer, Bernhard A1 - Ryden, H. A1 - Ronneteg, U. T1 - POD (Probability of Detection) Evaluation of NDT Techniques for Cu-Canisters for Risk Assessment of Nuclear Waste Encapsulation T2 - 9th European Conference on NDT CY - Berlin, Germany DA - 2006-09-25 KW - Zerstörungsfreie Prüfung KW - Zuverlässigkeit KW - POD KW - Endlagerung radioaktiver Abfälle PY - 2006 SN - 3-931381-86-2 N1 - Geburtsname von Rosenthal, Martina: Scharmach, M. - Birth name of Rosenthal, Martina: Scharmach, M. SP - 1(?) EP - 22(?) PB - European Federation for Non-Destructive Testing CY - Berlin AN - OPUS4-14419 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, Christina A1 - Elagin, Mstislav A1 - Bellon, Carsten A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Rosenthal, Martina A1 - Redmer, Bernhard A1 - Ryden, H. A1 - Ronneteg, U. T1 - Reliability evaluation of NDT techniques for Cu-welds for risk assessment of nuclear waste encapsulation KW - Zerstörungsfreie Prüfung KW - Zuverlässigkeit KW - POD KW - Endlagerung radioaktiver Abfälle PY - 2006 SN - 0025-5300 N1 - Geburtsname von Rosenthal, Martina: Scharmach, M. - Birth name of Rosenthal, Martina: Scharmach, M. VL - 48 IS - 3 SP - 111 EP - 117 PB - Carl Hanser Verlag CY - München AN - OPUS4-14421 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Christina A1 - Elagin, Mstislav A1 - Bellon, Carsten A1 - Ewert, Uwe A1 - Zscherpel, Uwe A1 - Scharmach, M. A1 - Redmer, Bernhard A1 - Ryden, H. A1 - Ronneteg, U. ED - Bièth, M. ED - Whittle, J. T1 - POD (Probability of Detection) Evaluation of NDT Techniques for Cu-Canisters for Risk Assessment of Nuclear Waste Encapsulation T2 - 5th International Conference on NDE in Relation to Structural Integrity for Nuclear and Pressurised Components CY - San Diego, CA, USA DA - 2006-05-10 KW - Zerstörungsfreie Prüfung KW - Zuverlässigkeit KW - POD PY - 2007 SN - 978-92-79-06107-3 SN - 1018-5593 N1 - Serientitel: JRC Scientific and Technical Reports – Series title: JRC Scientific and Technical Reports IS - Paper 1005 SP - 274 EP - 295 PB - Office for Official Publications of the European Communities CY - Luxembourg AN - OPUS4-15887 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Ewert, Uwe ED - Thompson, D. O. T1 - Reliability assessment by simulation for high energy radiography T2 - 33th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Portland, OR, USA DA - 2006-07-30 KW - Simulation KW - Radiography KW - CAD KW - Probability of Detection PY - 2007 SN - 978-0-7354-0399-4 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings IS - 894 SP - 1831 EP - 1838 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-15696 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten T1 - Analytische Modellierung für die Radiologie mit ARTIST - analytical RT inspection simulation tool T2 - DGZfP-Jahrestagung 2007 CY - Fürth, Deutschland DA - 2007-05-14 KW - Radiographie KW - Computer-Simulation PY - 2007 SN - 978-3-931381-98-1 SP - 1 EP - 2 PB - DGZfP CY - Berlin AN - OPUS4-15998 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten T1 - Modellierung digitaler radiographischer Techniken im Rahmen des FilmFree Projektes T2 - DGZfP-Jahrestagung 2007 CY - Fürth, Deutschland DA - 2007-05-14 KW - Radiographie KW - Computer-Simulation PY - 2007 SN - 978-3-931381-98-1 SP - 1 EP - 5 PB - DGZfP CY - Berlin AN - OPUS4-15997 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten T1 - Modellierung digitaler radiographischer Techniken im Rahmen des FilmFree Projektes T2 - DGZfP Jahrestagung 2007 CY - Fürth, Germany DA - 2007-05-14 PY - 2007 AN - OPUS4-15474 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - Simulation in der Röntgentechnik T2 - VDEh Unterausschuss für zerstörungsfreie Prüfung und Messtechnik CY - Salzgitter, Germany DA - 2007-09-19 PY - 2007 AN - OPUS4-16027 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - aRTist - analytical RT inspection simulation tool T2 - International Symposium on Digital Industrial Radiology and Computed Tomography DIR 2007 CY - Lyon, France DA - 2007-06-25 PY - 2007 AN - OPUS4-15473 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ewert, Uwe A1 - Beckmann, Jörg A1 - Bellon, Carsten A1 - Jaenisch, Gerd-Rüdiger A1 - Zscherpel, Uwe A1 - Jechow, Mirko T1 - Fehlergrößenabhängige Kontrastreduktion und zusätzliche Unschärfe durch Streustrahlung - Film und digitale Detektoren im Vergleich N2 - Die radiografische Bildqualität in ihrer klassischen Definition hängt von Kontrast, Rauschen und Unschärfe ab. Diese Parameter werden normalerweise mit Bildgüteprüfkörpern (BPK) bestimmt. Die Streustrahlung reduziert im Allgemeinen immer die Bildqualität in der Radiografie. Verschiedene Einflussgrößen werden unter Berücksichtigung von Techniken, wie Film-Radiografie, Computer-Radiografie mit Speicherfolien und digitale Radiographie mit Matrixdetektoren, analysiert. In Lehrbüchern und Standards werden das Streuverhältnis k und verschiedene Kontraste definiert. Für digitale Medien werden zusätzliche Parameter wie das Signal-Rausch-Verhältnis SNR und das Kontrast-Rausch-Verhältnis CNR eingeführt. In diesem Zusammenhang wird der Einfluss der Streustrahlung aus dem Messobjekt und dem Detektor bestehend aus Kassette bzw. Gehäuse und sensitiver Detektorschicht auf die Bildqualität ermittelt. Die numerische Modellierung wird eingesetzt, um die Streustrahlung und die Primärstrahlung aus dem Objekt separat zu bestimmen. Die Streustrahlung aus dem Objekt und Detektor erzeugen eine Abbildung des Objektes, die dem Primärstrahlungsbild überlagert ist, wobei das Streubild eine höhere Unschärfe aufweist. Dieser Effekt hängt von der Fehlergröße, dem Abstand zwischen Detektor und Objekt und der Zwischenfilterung ab. KW - Digitale Radiologie KW - Kontrast-Rausch-Verhältnis KW - Streuverhältnis KW - Röntgen Simulation PY - 2008 SN - 0025-5300 VL - 50 IS - 10 SP - 560 EP - 568 PB - Hanser CY - München AN - OPUS4-18346 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Ewert, Uwe T1 - aRTist - Analytical RT Inspection Simulation Tool for Industrial Application T2 - 17th World Conference on Non-Destructive Testing CY - Shanghai, China DA - 2008-10-25 KW - Computer Simulation KW - Radiography KW - Computed Tomography KW - Ray Tracing PY - 2008 SP - 1 EP - 6 PB - International Committee for Non-Destructive Testing CY - Shanghai AN - OPUS4-18584 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten A1 - Jaenisch, Gerd-Rüdiger T1 - aRTist - Analytical RT Inspection Simulation Tool T2 - DIR 2007 - International Symposium on Digital industrial Radiology and Computed Tomography CY - Lyon, France DA - 2007-06-25 KW - Computer Simulation KW - Radiography KW - Computed Tomography KW - Ray Tracing PY - 2007 UR - http://www.ndt.net/article/dir2007/papers/s1.pdf SP - 1 EP - 5 CY - Lyon, France AN - OPUS4-16086 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Schumm, A. A1 - Tabary, J. A1 - Duvauchelle, P. ED - Thompson, D. O. ED - Chimenti, D. E. T1 - A proposed benchmark problem for scatter calculations in radiographic modelling T2 - 35th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Chicago, IL, USA DA - 2008-07-20 KW - Radiography KW - Justifications or modifications of Monte Carlo methods KW - Emission KW - Absorption, and scattering of electromagnetic radiation KW - X-ray scattering KW - Radiographie KW - Simulation KW - Benchmark KW - Monte Carlo Verfahren KW - Streustrahlung PY - 2009 SN - 978-0-7354-0629-2 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings IS - 1096 SP - 1930 EP - 1937 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-20134 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zscherpel, Uwe A1 - Alekseychuk, Oleksandr A1 - Bellon, Carsten A1 - Ewert, Uwe A1 - Rost, P. A1 - Schmid, M. T1 - Korrosionsmapping an Rohrleitungen T2 - DGZfP-JAHRESTAGUNG 2002 CY - Weimar, Germany DA - 2002-05-06 PY - 2002 AN - OPUS4-19974 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Schumm, A. A1 - Tabary, J. A1 - Duvauchelle, P. ED - Thompson, D.O. ED - Chimenti, D.E. T1 - Radiographic benchmark problem 2009 - scatter calculations in modelling T2 - 36th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Kingston, RI, USA DA - 2009-07-26 KW - Radiography KW - Justifications or modifications of Monte Carlo methods KW - Emission KW - Absorption and scattering of electromagnetic radiation KW - X-ray scattering KW - Simulation KW - Röntgenspektrum Benchmark KW - Monte Carlo Modell PY - 2010 SN - 978-0-7354-0748-0 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings VL - 1211 SP - 2117 EP - 2124 CY - Melville, NY AN - OPUS4-21137 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zhukovskiy, M. A1 - Skachkov, M. A1 - Deresch, Andreas A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten ED - Thompson, D.O. ED - Chimenti, D.E. T1 - Simulation of electron transport T2 - 36th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Kingston, RI, USA DA - 2009-07-26 KW - Electron transport KW - Monte Carlo method KW - Stopping power KW - Simulation KW - Elektronentransport PY - 2010 SN - 978-0-7354-0748-0 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings VL - 1211 SP - 572 EP - 578 CY - Melville, NY AN - OPUS4-21134 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Deresch, Andreas A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Warrikhoff, A. ED - Thompson, D.O. ED - Chimenti, D.E. T1 - Simulation and experimental verification of X-ray spectra T2 - 36th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - Kingston, RI, USA DA - 2009-07-26 KW - X-ray KW - Spectrum KW - Simulation KW - Röntgenspektrum KW - Dekonvolution PY - 2010 SN - 978-0-7354-0748-0 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings VL - 1211 SP - 535 EP - 540 CY - Melville, NY AN - OPUS4-21136 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Zhukovskiy, M. A1 - Skachkov, M. A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Deresch, Andreas T1 - Monte Carlo simulating the electron emission from surfaces of objects being under radiation T2 - 10th European conference on non-destructive testing CY - Moscow, Russia DA - 2010-06-07 KW - Simulation KW - Elektronentransport PY - 2010 IS - Paper 4.02.18 SP - 1 EP - 10 AN - OPUS4-22764 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Deresch, Andreas A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Warrikhoff, A. T1 - Optimization of X-ray sources by modeling T2 - 10th European conference on non-destructive testing CY - Moscow, Russia DA - 2010-06-07 KW - Simulation KW - Elektronentransport KW - Röntgenquellen PY - 2010 IS - Paper 4.02.18 SP - 1 EP - 10 AN - OPUS4-22766 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Ewert, Uwe T1 - Simulation supported reliability analysis in radiography T2 - 10th European conference on non-destructive testing CY - Moscow, Russia DA - 2010-06-07 KW - Simulation KW - Zuverlässigkeit KW - POD PY - 2010 IS - Paper 4.02.18 SP - 1 EP - 13 AN - OPUS4-22767 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - Simulation of Complex Scan Paths for 3D Reconstruction T2 - International Symposium on Digital Industrial Radiology and Computed Tomography CY - Berlin, Germany DA - 2011-06-20 PY - 2011 AN - OPUS4-24383 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Schulze, M. A1 - Staude, Andreas A1 - Neukamm, M. A1 - Neuschaefer-Rube, U. A1 - Goebbels, Jürgen A1 - Bartscher, M. A1 - Bellon, Carsten A1 - Hilpert, U. ED - Weckenmann, A. T1 - Hochgenaue Geometriebestimmung von Mikrobauteilen mit Computertomographie (CT) N2 - Ziel des Vorhabens ist die hochgenaue und vollständige Erfassung innerer und äußerer Geometrien von Mikrobauteilen mittels Mikro-Computertomographie (µCT). Industriell wichtige Mikrobauteile sind z.B. Einspritzsysteme, Festplattenkomponenten oder Instrumente für die minimal-invasive Chirurgie. Typische Bauteilgrößen liegen hier im Bereich 0,1 mm - 100mm; typische zu messende Strukturen haben Größen von 0,5 µm - 500 µm. Mit klassischen Methoden der Messtechnik ist eine schnelle und hochgenaue Erfassung der gesamten Oberfläche von Mikrobauteilen bisher kaum möglich. Innenstrukturen von Mikrobauteilen können mit keiner optischen oder taktilen Messtechnik zerstörungsfrei gemessen werden. Diese Einschränkungen sollen mittels hochgenauer µCT überwunden werden. Hierzu soll der Messprozess simuliert werden, um die Anwendung von Korrekturverfahren zur Genauigkeitssteigerung zu ermöglichen. CT-Messungen an kalibrierten Mikroprüfkörpern sollen die Korrekturverfahren verifizieren. Für die Kalibrierung der Prüfkörper sollen Multisensor-Verfahren entwickelt und getestet werden. Diese sollen es erlauben, Prüfkörper gleichzeitig hochgenau und mit großer Messpunktdichte zu kalibrieren. Es ist geplant, die an Prüfkörpern erreichten Messunsicherheiten und Auflösungen zum Projektabschluss an realen, industriellen Mikrobauteilen (z.B. Mikrozahnrädern) messtechnisch nachzuweisen. T2 - Abschlusskolloquium DFG Schwerpunktprogramm 1159 - Neue Strategien der Mess- und Prüftechnik für die Produktion von Mikrosystemen und Nanostrukturen CY - Erlangen, Deutschland DA - 06.10.2010 PY - 2011 SN - 978-3-8440-0358-1 SN - 0945-0769 SP - 36 EP - 52 PB - Shaker Verlag GmbH AN - OPUS4-24875 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Deresch, Andreas A1 - Bellon, Carsten A1 - Ewert, Uwe A1 - Przybilla, Waldemar ED - Thompson, D.O. ED - Chimenti, D.E. T1 - Measurement and modeling of scatter ratios at high energies N2 - Determining scatter ratios at high energies (> ~ 1MeV) presents challenges not immediately obvious from measurements at conventional X-ray energies. This includes reduced attenuation even in heavy elements as well as a stronger forward bias of scattering. In order to check the reliability of different measurement setups with regard to material thicknesses, distances, and collimation, attenuation and scattering were separately simulated using a Monte Carlo model. The simulation results help in understanding the sources of radiation scattered into the detection area, thereby aiding in eliminating undesired contributions. T2 - 37th Annual Review of Progress in Quantitative Nondestructive Evaluation CY - San Diego, CA, USA DA - 18.07.2010 KW - Radiography KW - Optimisation KW - X-ray detection KW - Simulation KW - High energy KW - Co-60 KW - Modeling KW - Scatter PY - 2011 SN - 978-0-7354-0888-3 DO - https://doi.org/10.1063/1.3591895 SN - 0743-0760 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings IS - 1335 SP - 517 EP - 524 PB - American Institute of Physics CY - Melville, NY AN - OPUS4-25358 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - Realistic Simulation of CT Systems - An Introduction to The CTSimU2 Project N2 - The project series CTSimU was initiated with the goal to develop a set of procedures to enable the determination of the task-specific measurement uncertainty of a CT system numerically by radiographic simulation. The first project (2019-2022) “Radiographic Computed Tomography Simulation for Measurement Uncertainty Evaluation - CTSimU” was focused on the sufficient physical correctness of the radiographic simulation and created as a result a test framework for simulation softwares and a draft of a VDI standard in the series VDI/VDE 2630 for this application. However, for the realistic simulation of a CT system in a simulation software (i.e. a digital twin), not only the correctness of the simulation software itself is crucial, but also the quality of the parameterization of the CT system in the simulation software - this represents the starting point of the 2nd project “Realistic Simulation of real CT systems with a basic-qualified Simulation Software - CTSimU2” (2022-2024). The parameterization of a CT system in a simulation software can be divided into four steps: after the data acquisition at the real CT system (step 1) follows the evaluation of the acquired data for the generation of general parameter specifications (step 2). It follows the transfer of the parameters into the specific simulation software (step 3) and the validation of the resulting simulation parameters by a suitable test (step 4). The intended result of the project CTSimU2 is a draft VDI standard (for VDI/VDE 2630) for this test, which contains an informative annex on the state of the art regarding the possibilities for parameter determination. T2 - 13th European Conference on Non-Destructive Testing (ECNDT) CY - Lisbon, Portugal DA - 03.07.2023 KW - X-ray computed tomography KW - dXCT KW - Simulation PY - 2023 AN - OPUS4-58923 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - Virtual CT with aRTist N2 - The software aRTist is a simulation tool for the generation of realistic radiographs of virtual radiographic superstructures. With radiographic simulations, virtual component models can be scanned as in a computer tomograph. Industrial X-ray computed tomography (CT) enables the non-destructive detection of internal and external surfaces as well as inhomogeneities of technical objects. Virtual CT offers new possibilities for the investigation of parameter influences of this complex testing and measuring technique. In addition to the option of switching physical effects on and off, scanning movements can also be tested before their technical realization. The virtual CT generates projection images from different directions for the subsequent reconstruction of a volume model of the examined object. The reconstruction of the simulated scans is carried out with the algorithms and programs for real scans. Tomographic scans consist of a large number of projections, which practically cannot be generated individually by the user of a simulation. The software offers various options for the automated simulation of tomographic scans. These range from standard CT to scans on free trajectories or with individual projection matrices. T2 - 12th Conference on Industrial Computed Tomography (iCT) 2023 CY - Fürth, Germany DA - 27.02.2023 KW - X-ray computed tomography KW - Simulation PY - 2023 AN - OPUS4-58919 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bellon, Carsten T1 - Virtuelle CT N2 - Das Computerprogramm aRTist ist ein praktisches Simulationswerkzeug zur Erzeugung realistischer Radiographien virtueller Durchstrahlungsaufbauten. Mit Durchstrahlungssimulationen können Bauteile, repräsentiert durch STL-Geometrien, wie in einem Computertomografen gescannt werden. Dabei werden verschiedenste Parameter gezielt und exakt berücksichtigt. Die Virtuelle Computertomografie bietet neue Möglichkeiten der Untersuchung von Parametereinflüssen. Neben der Möglichkeit, physikalische Effekte an- und abzuschalten, z.B. die Streustrahlung, können auch Scanbewegungen getestet werden, bevor diese technisch realisiert werden. Das für die Forschung entwickelte Simulationsprogramm aRTist bietet mit seiner intuitiven grafischen Benutzeroberfläche vielfältige Anwendungsmöglichkeiten auch in Praxis und Entwicklung, beispielsweise zur Parameteroptimierung, für Machbarkeitsstudien oder zur Abschätzung der Unsicherheit dimensioneller Messungen. KW - Vituelle Computertomographie Simulation PY - 2020 SN - 2199-8299 VL - 2020 IS - April SP - 50 EP - 51 PB - TeDo Verlag GmbH CY - Marburg AN - OPUS4-50691 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - AdvanCT Virtual CT N2 - Simulation becomes more and more important in modern CT imaging. It is increasingly used to optimize techniques for complex applications, and for educational purposes. Simulation can also be used for uncertainty estimation of dimensional CT measurements. The radiographic simulator aRTist is a modelling tool which simulates X-ray imaging using a hybrid analytical and Monte-Carlo method to efficiently model the radiation transport. In addition to the relevant physical effects such as absorption and scattering, simplified fast models are employed to describe the characteristics of the X-ray source and the detector. aRTist is well equipped to model realistic X-ray imaging setups due to the ability to load exported CAD object descriptions. By repetitive simulation runs aRTist can function as virtual CT device. A simple CT scan module is contained in aRTist which allows the simulation of standard (circular cone beam) scanning trajectories. AdvanCT is a module for aRTist which allows to set up more complex scanning trajectories by attaching geometrical modification functions to the objects in the radiographic scene. In this way, advanced scanning modes can be realized. In addition to deterministic motion, also random variations can be introduced. By combining random variations with deterministic motion, non-ideal (realistic) CT scan geometries can be simulated, e.g. focal spot drift and mechanical instability of the axis of rotation. The AdvanCT module conveniently allows to construct these scenarios in a graphical interface and provides a preview before starting the (potentially long running) batch job. Therefore, deviations from ideal CT scan trajectories can be easily adjusted which is a necessary step towards uncertainty determination from simulation. T2 - dXCT conference 2021 CY - Online meeting DA - 17.05.2021 KW - X-ray Virtual Computer Tomography Simulation PY - 2021 AN - OPUS4-52953 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - CTSimU — Durchstrahlungssimulation für die Messunsicherheitsbestimmung beim Messen geometrischer Merkmale mittels Röntgen- Computertomographie N2 - Die industrielle Röntgen-Computertomographie (CT) ist in der geometrischen Messtechnik die einzige Technologie, die sowohl innen- als auch außenliegende Merkmale eines Werkstücks mit einer Messung zerstörungsfrei messen kann. Die Güte der Messung kann mittels einer dem Messwert beigeordneten Messunsicherheit angegeben werden. Allerdings sind zur Ermittlung der Messunsicherheit für eine Messgröße einer CT-Messung nach Stand der Technik (VDI/VDE 2630 Blatt 2.1) zwanzig Wiederholmessungen an kalibrierten Werkstücken notwendig. Da die Messung mit realen CT-Messgeräten zeit- und kostenintensiv ist, wird analog zur taktilen Koordinatenmesstechnik eine numerische Messunsicherheitsbestimmung durch Simulation angestrebt (vgl. VDI/VDE 2617 Blatt 7, GUM Supplement 1). Die Simulation bietet den Vorteil, dass sie sowohl zeitsparend als auch kosten- und ressourceneffizient ist. Allerdings ist die Zuverlässigkeit der verschiedenen Simulationsumgebungen momentan nicht quantifizierbar. Für eine glaubwürdige Anwendung von Simulationsumgebungen für die Messunsicherheitsbestimmung benötigen Anwender eine Beurteilung derselben – auch um eine Norm- bzw. Richtliniensicherheit in der Praxis sicherzustellen. Das Ziel dieses Projekts ist es daher, einen Richtlinienentwurf VDI/VDE 2630 Blatt 2.2 „Basisqualifizierung von Softwaresystemen für die Simulation geometrischer Messungen mit Röntgen-Computertomografie“ zu erstellen. Auf dieser Basis soll es möglich sein, die Eignung von Simulationsumgebungen zur Ermittlung der aufgabenspezifischen Messunsicherheit zu bewerten. Dazu wird ein Testframework entwickelt, mit welchem Durchstrahlungssimulationssoftwares basisqualifiziert werden können. Das Projekt wird in der Förderrichtlinie WIPANO durch das Bundesministerium für Wirtschaft und Energie gefördert. T2 - DGZfP-Jahrestagung 2021 CY - Online meeting DA - 10.05.2021 KW - Computertomographie Simulation PY - 2021 AN - OPUS4-52753 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten A1 - Deresch, Andreas A1 - Gollwitzer, Christian A1 - Jaenisch, Gerd-Rüdiger T1 - Radiographic simulator aRTist: version 2 N2 - Computer simulation of radiography can be used for different purposes in NDT, such as qualification of NDT systems, optimization of radiographic parameters, feasibility analysis, model-based data interpretation, and training of NDT/NDE personnel. BAM has been working on modeling in the field of radiographic testing for many years. With the gathered theoretical background and the familiarity with practical requirements of industrial application the simulation software aRTist has been developed. This analytical simulator includes a description of the radiation source, the interaction of radiation with test pieces and flaws, and the detection process with special focus on film and digital industrial radiology. It features high processing speed with nearinteractive frame rates and a high level of realism. Here we focus on the recent developments of the simulator, notably the release of aRTist version 2. Extended functionality regarding automated virtual computed tomography now allows for arbitrary scan paths. Another program extension supports reliability investigations and provides a user interface for planning automatic simulations with varying parameters and defects. T2 - 18th WCNDT - World conference on nondestructive testing CY - Durban, South Africa DA - 16.04.2012 KW - X-ray imaging KW - Radiographic testing KW - Simulation KW - Computed tomography PY - 2012 SN - 978-0-620-52872-6 SP - 1 EP - 7 (Paper 333) AN - OPUS4-27398 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Deresch, Andreas A1 - Jaenisch, Gerd-Rüdiger A1 - Bellon, Carsten A1 - Warrikhoff, A. T1 - Simulating X-ray spectra: from tube parameters to detector output N2 - A model is discussed which describes the generation of X-rays in conventional tubes using tabulated bremsstrahlung energy spectra depending on three variables: the target atomic number, the incident electron kinetic energy, and the fraction of energy radiated. Additionally a parameter-free description of the characteristic radiation is included. The constructed model includes technical tube parameters like kilovoltage, target material, and angles of electron incidence and photon emission to also account for self-absorption in the target, as well as radiographic parameters like filtering. In order to verify model results, detector response is also considered. The validity of the proposed model is shown by measurements. Future work includes the extension of the model to transmission targets. This research was supported by the German Federal Ministry of Economics and Technology under contract MNPQ transfer II D 5-30/06. T2 - 18th WCNDT - World conference on nondestructive testing CY - Durban, South Africa DA - 2012-04-16 KW - X-ray KW - Spectrum KW - Simulation PY - 2012 SN - 978-0-620-52872-6 SP - 1 EP - 8 (Paper 336) AN - OPUS4-27399 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Gollwitzer, Christian A1 - Bellon, Carsten A1 - Deresch, Andreas A1 - Jaenisch, Gerd-Rüdiger A1 - Baron, H.-U. A1 - Ewert, Uwe T1 - Reliability investigations of radiographic testing using aRTist as a simulation tool N2 - Within the framework of the European project PICASSO, the radiographic simulator aRTist (analytical Radiographic Testing inspection simulation tool) developed by BAM has been extended for reliability assessment of film and digital radiography. A simulation supported probability of detection (POD) methodology has been developed and the validity of the approach has been studied using an application from the aeronautics industry. An experimental POD has been determined with the help of a specialized software tool, developed to aid with the collection of large series of POD data. The resulting POD is compared to simulations of the same setting using aRTist and the newly available module for simulation supported POD. A quantitative agreement within a few percent is achieved between the experimental and the simulation supported POD. T2 - 18th WCNDT - World conference on nondestructive testing CY - Durban, South Africa DA - 2012-04-16 KW - X-ray imaging KW - Probability of detection KW - Simulation PY - 2012 SN - 978-0-620-52872-6 SP - 1 EP - 10 (Paper 338) AN - OPUS4-27400 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Jaenisch, Gerd-Rüdiger A1 - Deresch, Andreas A1 - Bellon, Carsten A1 - Schumm, A. A1 - Guerin, P. ED - Chimenti, D.E. ED - Bond, L.J. ED - Thompson, D.O. T1 - A proposed benchmark for simulation in radiographic testing N2 - The purpose of this benchmark study is to compare simulation results predicted by various models of radiographic testing, in particular those that are capable of separately predicting primary and scatter radiation for specimens of arbitrary geometry. T2 - 40th Annual review of progress in quantitative nondestructive evaluation CY - Baltimore, Maryland, USA DA - 21.07.2013 KW - Benchmark KW - Simulation KW - Radiographic testing PY - 2014 SN - 978-0-7354-1212-5 SN - 978-0-7354-1211-8 DO - https://doi.org/10.1063/1.4865082 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings VL - 1581 SP - 2101 EP - 2106 PB - AIP Publishing AN - OPUS4-30756 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bellon, Carsten T1 - Zuverlässigkeit radiografischer Prüfungen und Simulationen T2 - DGZfP-Jahrestagung 2013 CY - Dresden, Germany DA - 2013-05-06 PY - 2013 AN - OPUS4-29751 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ewert, Uwe A1 - Deresch, Andreas A1 - Bellon, Carsten A1 - Jaenisch, Gerd-Rüdiger ED - Chimenti, D.E. ED - Bond, L.J. ED - Thompson, D.O. T1 - A benchmark concept for simulation in radiographic testing N2 - The new standard ISO 17636–2:2013 'NDT of welds: Radiographic testing - Part 2: X- and gamma ray techniques with digital detectors' describes a complex procedure for film replacement by phosphor imaging plates and digital detector arrays. RT modeling software should consider these detector types, X-ray film, and the standard requirements for image quality. Practitioners expect the same visibility of image quality indicators (IQI) in the simulated radiographs as in the experimental exposures. The proposed benchmark test is based on the comparison of experimental radiographs taken at BAM with modeled ones of participants. The experimental setup and the determination of the equivalent penetrameter sensitivity (EPS) as described in the procedure of ASTM E 746 are used for quantitative evaluation of the achievable contrast sensitivity for step hole IQIs as considered in Annex B of ISO 17636-2. System classification data for Computed Radiography (CR) and film systems will be provided by BAM according to ISO 11699–1 for selected film systems and according to ASTM E 2446 for selected CR systems. The classification of films and digital detectors is based on the measurement of the dose response function, the basic spatial resolution (SRb) of the image, and the measured image noise, which depends on the detector efficiency, the quantum statistics, and the detector fixed pattern noise. T2 - 40th Annual review of progress in quantitative nondestructive evaluation CY - Baltimore, Maryland, USA DA - 21.07.2013 KW - Digital radiography KW - Computed radiography KW - Benchmark KW - EPS KW - Modeling KW - Simulation KW - Contrast to noise ratio KW - Observer model PY - 2014 SN - 978-0-7354-1212-5 SN - 978-0-7354-1211-8 DO - https://doi.org/10.1063/1.4865044 SN - 0094-243X N1 - Serientitel: AIP conference proceedings – Series title: AIP conference proceedings VL - 33A SP - 1816 EP - 1823 PB - AIP Publishing AN - OPUS4-30904 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -