TY - JOUR A1 - Bonse, Jörn A1 - Hertwig, Andreas A1 - Koter, Robert A1 - Weise, Matthias A1 - Beck, Uwe A1 - Reinstädt, Philipp A1 - Griepentrog, Michael A1 - Krüger, Jörg A1 - Picquart, M. A1 - Haro-Poniatowski, E. T1 - Femtosecond laser pulse irradiation effects on thin hydrogenated amorphous carbon layers N2 - The irradiation of ~0.9-µm-thick hydrogenated amorphous carbon (a-C:H) layers deposited on silicon substrates with single femtosecond (fs) laser pulses (35 fs pulse duration, 790 nm centre wavelength) in air is studied experimentally. Irradiation spots have been generated with different peak fluences and subsequently investigated by optical topometry, micro Raman spectroscopy and microscale mechanical indentation in order to evaluate their microscopic, topographical, structural and mechanical properties (e.g. elastic modulus). By this multi-method approach, a clear separation of different effects (delamination and graphitisation) becomes possible. The joint application of mechanical and spectroscopic techniques provides unique insights into the effects of the fs-laser radiation on the carbon layer. PY - 2013 DO - https://doi.org/10.1007/s00339-012-7170-5 SN - 0947-8396 VL - 112 IS - 1 SP - 9 EP - 14 PB - Springer CY - Berlin AN - OPUS4-28629 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Beck, Uwe A1 - Hielscher, Stefan A1 - Kittler-Packmor, Kai A1 - Stockmann, Jörg M. A1 - Lerche, D. A1 - Rietz, U. ED - Petzow, G. T1 - Zentrifugentechnologie in der Beanspruchung auf Zug bzw. Druck: Klebfestigkeit, Schichthaftung, Materialhärte N2 - Für die Prüfung der Festigkeit in der Beanspruchung auf Zug oder Druck wurden bisher Zug- bzw. Härteprüfmaschinen verwendet. In der Beanspruchung auf Zug ist die Probe beidseitig, und um das Einleiten von Querkräften zu verhindern, oft doppeltkardanisch einzuspannen. In jedem Falle handelt es sich um Ein-Proben-Prüfungen. Bei der Zentrifugentechnologie wird mit der Zentrifugalkraft als Prüfkraft erstmals in einer Mehr-Proben-Anordnung gearbeitet. Da die Proben nur einseitig unterstützt werden müssen, ist die Beladung über einfaches Einstecken realisierbar. Mit dem Auf-Tisch-Prüfsystem können bis zu acht Proben gleichzeitig auf Zug oder Druck beansprucht werden. Ein aufgeklebter oder anderweitig mit dem Prüfkörper verbundener Prüfstempel bewegt sich unter Einwirkung der Zentrifugalkraft in einer Führungshülse radial nach außen und beansprucht die Klebung, die Beschichtung oder den Verbund auf Zug bis zum Versagen. Im Augenblick des Abrisses wird ein positionscodiertes und drehzahlkorreliertes Signal gesendet und so die Bestimmung von Kleb-, Haft- bzw. Verbundfestigkeiten im Mehr-Proben-Versuch ermöglicht. Analog beansprucht ein in einer Führungshülse radial innen an den Proben anliegender, ggf. mit entsprechenden Eindringkörpern ausgerüsteter, nach außen gerichteter Prüfstempel die Proben auf Druck. Aus der Drehzahl beim Abriss (Beanspruchung auf Zug) bzw. der Maximaldrehzahl (Beanspruchung auf Druck), dem Radius und der Prüfstempelmasse können dann Festigkeits- bzw. Härtewerte berechnet werden. Die Zentrifugentechnologie ist sowohl in der Beanspruchung auf Zug als auch in der Beanspruchung auf Druck durch Patente geschützt und wurde erstmals in beschrieben. Als Mehr-Proben-Prüfung hat sie das Potential, Werkstoffkenngrößen von Anfang an auf statischer Basis unter wirklich identischen Versuchsbedingungen zu ermitteln. T2 - 47. Metallographie-Tagung CY - Friedrichshafen, Germany DA - 18.09.2013 KW - Klebfestigkeit KW - Haftfestigkeit KW - Verbundfestigkeit KW - Brinell- und Vickers Härte KW - Zentrifugentechnologie PY - 2013 SN - 978-3-88355-398-6 N1 - Geburtsname von Kittler-Packmor, Kai: Kittler, K. - Birth name of Kittler-Packmor, Kai: Kittler, K. VL - 45 SP - 157 EP - 162 AN - OPUS4-29276 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Thomsen-Schmidt, P. A1 - Hasche, K. A1 - Ulm, G. A1 - Herrmann, K. A1 - Krumrey, M. A1 - Ade, G. A1 - Stümpel, J. A1 - Procop, Mathias A1 - Beck, Uwe T1 - Realisation and metrological characterisation of thickness standards below 100 nm T2 - DVG Jahrestagung 2002 CY - Magdeburg, Germany DA - 2002-06-17 PY - 2002 SP - 1 EP - 9 PB - Deutsche Vakuum-Gesellschaft CY - Kaiserslautern AN - OPUS4-1936 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Le, Quynh Hoa A1 - Bäßler, Ralph A1 - Bettge, Dirk A1 - Buggisch, E. A1 - Schiller, Bernadette Nicole A1 - Beck, M. T1 - Corrosion Study on Wellbore Materials for the CO2 Injection Process N2 - For reliability and safety issues of injection wells, corrosion resistance of materials used needs to be determined. Herein, representative low-cost materials, including carbon steel X70/1.8977 and low alloyed steel 1.7225, were embedded in mortar to mimic the realistic casing-mortar interface. Two types of cement were investigated: (1) Dyckerhoff Variodur commercial Portland cement, representing a highly acidic resistant cement and (2) Wollastonite, which can react with CO2 and become stable under a CO2 stream due to the carbonation process. Exposure tests were performed under 10 MPa and at 333 K in artificial aquifer fluid for up to 20 weeks, revealing crevice corrosion and uniform corrosion instead of expected pitting corrosion. To clarify the role of cement, simulated pore water was made by dispersing cement powder in aquifer fluid and used as a solution to expose steels. Surface analysis, accompanied by element mapping on exposed specimens and their crosssections, was carried out to trace the chloride intrusion and corrosion process that followed. KW - Carbon capture storage KW - CCS KW - Carbon dioxide KW - Corrosion KW - Carbon steel KW - Aquifer fluid KW - Cement KW - Casing KW - Pitting PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-519774 DO - https://doi.org/10.3390/pr9010115 SN - 2227-9717 VL - 9 IS - 1 SP - 115 PB - MDPI CY - Basel AN - OPUS4-51977 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Le, Quynh Hoa A1 - Bäßler, Ralph A1 - Schiller, B.N. A1 - Beck, M. A1 - Bettge, Dirk T1 - On the corrosion behaviour of co 2 injection pipe steels: role of cement N2 - Carbon Capture and Storage (CCS) is identified as an excellent technology to reach the target of CO2 reduction. However, the safety issue and cost-effectiveness hinder the future of CCS. For the reliability and safety issues of injection wells, the corrosion resistance of the materials used needs to be determined. In this study, representative low-cost materials including carbon steel 1.8977 and low alloyed steel 1.7225 were investigated in simulated pore water at 333 K and under CO2 saturation condition to represent the worst-case scenario: CO2 diffusion and aquifer fluid penetration. These simulated pore waters were made from relevant cement powder to mimic the realistic casing-cement interface. Electrochemical studies were carried out using the pore water made of cement powder dissolved in water in comparison with those dissolved in synthetic aquifer fluid, to reveal the effect of cement as well as formation water on the steel performance. Two commercially available types of cement were investigated: Dyckerhoff Variodur® and Wollastonite. Variodur® is a cement containing high performance binder with ultra-fine blast furnace slag which can be used to produce high acid resistance concrete. On the other hand, Wollastonite is an emerging natural material mainly made of CaSiO3 which can be hardened by converting to CaCO3 during CO2 injection. The results showed the pH-reducing effect of CO2 on the simulated pore water/aquifer (from more than 10 to less than 5) leading to the active corrosion process that happened on both 1.8977 and 1.7225. Electrochemical characterization showed negative free corrosion potential and polarisation curves without passive behaviors. The tested coupons suffered from pitting corrosion, which was confirmed by surface analysis. Interestingly, basing on the pit depth measurements from the tested coupons and the hardness of cement powder, it is suggested that Variodur® performed better than Wollastonite in both aspects. The electrochemical data was compared to that resulted from exposure tests to give a recommendation on material selection for bore-hole construction. T2 - EUROCORR 2019 CY - Sevilla, Spain DA - 09.09.2019 KW - Cement KW - Carbon capture KW - Corrosion and storage (CCUS) technology KW - Utilization KW - Carbon steel KW - Crevice corrosion PY - 2019 SP - Paper 200597, 1 EP - 4 PB - SOCIEMAT CY - Madrid, Spain AN - OPUS4-49109 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Duwe, M. A1 - Quast, J.-H. A1 - Schneider, S. A1 - Fischer, Daniel A1 - Beck, Uwe T1 - Thin-film metrology of tilted and curved surfaces by imaging Mueller-matrix ellipsometry N2 - For the vast majority of ellipsometric measurements, the application of planar substrates is mandatory and requires a proper sample alignment prior to the measurement. Here, the authors present a generalized approach of how to extract the isotropic ellipsometric sample parameters from an imaging Mueller-matrix measurement even if the sample is significantly misaligned. They validate the method by layer-thickness calculations based on imaging Mueller-matrix measurements of flat crystalline silicon samples that were misaligned on purpose. Furthermore, they also exploit this method’s capabilities to perform spatially resolved layer-thickness measurements of a single-layer indium-tin-oxide coating on a fused-silica microlens without the need of realignment or repositioning of the sample during the measurement. T2 - 8th International conference on spectroscopic ellipsometry (ICSE-8) CY - Barcelona, Spain DA - 26.05.2019 KW - Metrology KW - Thin films KW - Polarization spectroscopy KW - Spectroskopic Imaging KW - Mueller-Matrix imaging ellipsometry PY - 2019 DO - https://doi.org/10.1116/1.5122757 SN - 2166-2746 SN - 2327-9877 VL - 37 IS - 6 SP - 062908 PB - AIP CY - New York, NY AN - OPUS4-50209 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ickert, Stefanie A1 - Beck, S. A1 - Linscheid, M. A1 - Riedel, Jens T1 - VUV Photodissociation Induced by a Deuterium Lamp in an Ion Trap N2 - Tandem mass spectrometry represents an important analytical tool to unravel molecular structures and to study the gas-phase behavior of organic molecules. Besides commonly used methods like collision-induced dissociation and electron capture or transfer dissociation, new ultraviolet light–based techniques have the potential to synergistically add to the activation methods. Here, we present a new simple, yet robust, experimental design for polychromatic activation of trapped ions using the 115–160 nm output of a commercially available deuterium lamp. The resulting continuous dissociative excitation with photons of a wide energy range from 7.7 to 10.8 eV is studied for a comprehensive set of analyte classes in both positive and negative ion modes. While being simple, affordable, compact, and of low maintenance, the new setup initiates fragmentation of most precursor ions via their known dissociation pathways. Additionally, some new fragmentation patterns were discovered. Especially, electron loss and electron capture reactions with subsequent fragmentations were observed. For oligonucleotides, peptides, carbohydrates, and organic dyes, in comparison to collision-induced dissociation, a significantly wider fragment distribution was obtained, resulting in an information increase. Since the individual photons carry enough energy to post-ionize the nascent fragments, a permanent vacuum ultraviolet light exposure inside the ion trap potentially goes along with a general increase in detection capability. KW - Fragmentation activation KW - Vacuum ultraviolet (VUV) light KW - Mass spectrometry KW - Tandem MS PY - 2019 DO - https://doi.org/10.1007/s13361-019-02282-8 SN - 1044-0305 VL - 30 IS - 10 SP - 2114 EP - 2122 PB - Springer Nature CY - Heidelberg AN - OPUS4-48756 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fischer, Daniel A1 - Griepentrog, Michael A1 - Beck, Uwe A1 - Duwe, M. A1 - Quast, J.-H. A1 - Schneider, S. T1 - Effect of curvature of spherical microscopic indentations on the ellipsometric readout N2 - The authors describe and interpret curvature-related changes to the ellipsometric readout. As model system for a concave curvature, a set of three spherical microscopic indents in silicon (100) of different sizes was prepared by instrumented indentation testing using a spherical indenter. For reference, these samples were characterized by AFM to reveal the topography of each structure. The concavelike indents were analyzed by Mueller-Matrix imaging ellipsometry to extract lateral intensity images of 12 elements of the Mueller-Matrix. As a result of the detailed analysis of the image elements m22, m23, and m14, it was possible to correlate intensity changes and symmetry properties to depolarization and cross polarization induced by the edge threshold and the curved surface of the indent. KW - Spectroskopic Imaging KW - Mueller-Matrix imaging ellipsometry KW - Structural anomalies KW - Structural inhomogenities PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-498105 DO - https://doi.org/10.1116/1.5122252 VL - 37 IS - 6 SP - 062906-1 EP - 062906-5 PB - American Vacuum Society AN - OPUS4-49810 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Winkler, Juliette A1 - Beck, M. A1 - Gluth, Gregor ED - Schneider, F. ED - Hehl, K. ED - Heyde, S. T1 - Kurz- und mittelfristige Verbundfestigkeit von alkaliaktivierten Mörteln auf Beton N2 - Ein zentrales Fundament moderner Gesellschaften ist eine intakte Abwasserinfrastruktur. Schäden infolge biogener Schwefelsäurekorrosion von konventionellen Betonen haben jedoch zu einem erheblichen Sanierungsbedarf geführt. Alkaliaktivierte Mörtel besitzen aufgrund eines hohen Säurewiderstands das Potential, einen Beitrag zur langfristigen Lösung dieses Problems zu leisten. Dazu müssen jedoch zunächst die Faktoren, die den Haftverbund zwischen diesen Mörteln und dem Betonsubstrat bestimmen, besser verstanden werden, um die Eigenschaften der Beschichtungssysteme gezielt anpassen und verbessern zu können. Die vorliegende Arbeit liefert hierzu einen Beitrag und zeigt dadurch Wege zu einer technisch machbaren und nachhaltigen Sanierung von Abwasserbauwerken auf. KW - Alkalisch aktivierte Bindemittel KW - Abwassersysteme KW - Reparatursysteme KW - Verbund KW - Dauerhaftigkeit PY - 2022 SN - 978-3-8440-8818-2 SP - 89 EP - 100 CY - Berlin AN - OPUS4-57701 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schwarz, G. A1 - Müller, Larissa A1 - Beck, S. A1 - Linscheid, M.W. T1 - DOTA based metal labels for protein quantification: a review N2 - Today, quantitative data play a pivotal role in the understanding of biological processes. This is particularly true for the proteome: protein quantification always follows protein identification. To obtain useful and reliable quantitative data, rather sophisticated strategies using electrospray and MALDI mass spectrometry have been developed, which allow relative and sometimes even absolute quantification. All of those strategies have merits and limitations. In order to overcome some of these limits, methods based on the reliable and sensitive detection and quantification of heavy metals present in proteins using inductively coupled plasma (ICP)-MS have been reported. With specific labels carrying heavy metals, the applicability of ICP-MS has been extended to almost every protein. One of such covalently bound metal tags, allowing the quantification of low abundant proteins, uses 1,4,7,10-tetraazacyclododecane N,N',N'',N''-tetraacetic acid (DOTA) chelate complexes carrying lanthanides as the metal core. In this review the scope and limitations of peptide and protein quantification will be addressed. The metal tags do not only provide low detection limits, but also due to the large number of different lanthanides and lanthanide isotopes, multiplexing capabilities and previously unknown accuracy based on inherently possible isotope dilution methods came into reach. The developed workflows, including electrophoretic and chromatographic separation and preconcentration techniques, will be addressed to allow a comparison with already established procedures. KW - Protein quantification KW - ICP-MS KW - DOTA KW - Labeling PY - 2014 DO - https://doi.org/10.1039/c3ja50277e SN - 0267-9477 SN - 1364-5544 VL - 29 IS - 2 SP - 221 EP - 233 PB - Royal Society of Chemistry CY - London AN - OPUS4-30730 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hodoroaba, Vasile-Dan A1 - Hoffmann, V. A1 - Steers, E.B.M. A1 - Griepentrog, Michael A1 - Dück, Alexander A1 - Beck, Uwe T1 - Round Robin exercise: Coated materials for glow discharge spectroscopy N2 - A Round Robin (RR) exercise on selected coated materials has been carried out with the aim of finding the optimal conditions for the analysis of nitride layers with GD-OES. Such pre-normative work is necessary for the evaluation of parallel development of the production of nitride layers as certified reference materials (CRMs). Two types of samples, Ti–N layer and V–N layer, respectively, with chemical compositions close to stoichiometry and a thickness of ~3 µm, deposited on a steel substrate, have been provided to the RR participants. Additionally, another type of sample, a (100 nm CrNi/100 nm Cu) multilayer (ML) stack deposited on silicon wafer has also been included in the RR. This sample can be used as a CRM for checking GD spectrometer conditions and it has been proved helpful in further development of GDS instrumentation and methodology. The RR exercise has been performed in the frame of the EC Thematic Network on Glow Discharge Spectroscopy for Spectrochemical Analysis (‘GDS-Net’). KW - Coated/Layered Reference Materials KW - Nitrides KW - Multilayer KW - GDS KW - Round Robin PY - 2006 DO - https://doi.org/10.1039/B513426A SN - 0267-9477 SN - 1364-5544 VL - 21 IS - 1 SP - 74 EP - 81 PB - Royal Society of Chemistry CY - London AN - OPUS4-11762 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schwarz, G. A1 - Beck, S. A1 - Weller, Michael G. A1 - Linscheid, M.W. T1 - Comparison of the fragmentation behavior of differentially metal-coded affinity tag (MeCAT)-labeled peptides N2 - Mass spectrometry (MS) became a pivotal technique in the still growing field of quantitative proteomics, since system biology needs quantitative information. This development is not only driven by newly arising demands, but from the availability of modern instrumentation and new quantitative methods. Thus, techniques like isotope-coded affinity tags, isobaric tag for relative and absolute quantification and stable isotope labeling with amino acids in cell culture have been used routinely in many laboratories for years. However, only a few of the methods in quantitative proteomics offer absolute quantification.[5–8] Most approaches only deliver relative quantification data by direct comparison of two or more samples. PY - 2012 DO - https://doi.org/10.1002/jms.3036 SN - 1076-5174 SN - 1096-9888 VL - 47 IS - 7 SP - 885 EP - 889 PB - Wiley CY - Chichester AN - OPUS4-27436 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schwarz, Gunnar A1 - Beck, S. A1 - Weller, Michael G. A1 - Linscheid, M.W. T1 - MeCAT - new iodoacetamide reagents for metal labeling of proteins and peptides N2 - Besides protein identification via mass spectrometric methods, protein and peptide quantification has become more and more important in order to tackle biological questions. Methods like differential gel electrophoresis or enzyme-linked immunosorbent assays have been used to assess protein concentrations, while stable isotope labeling methods are also well established in quantitative proteomics. Recently, we developed metalcoded affinity tagging (MeCAT) as an alternative for accurate and sensitive quantification of peptides and proteins. In addition to absolute quantification via inductively coupled plasma mass spectrometry, MeCAT also enables sequence analysis via electrospray ionization tandem mass spectrometry. In the current study, we developed a new labeling approach utilizing an iodoacetamide MeCAT reagent (MeCAT-IA). The MeCAT-IA approach shows distinct advantages over the previously used MeCAT with maleinimide reactivity such as higher labelling efficiency and the lack of diastereomer formation during labeling. Here, we present a careful characterization of this new method focusing on the labeling process, which yields complete tagging with an excess of reagent of 1.6 to 1, less complex chromatographic behavior, and fragmentation characteristics of the tagged peptides using the iodoacetamide MeCAT reagent. KW - Quantitative proteomics KW - Mass spectrometry KW - Metal labeling KW - Stable isotope labeling KW - Lanthanide DOTA KW - Metall-Markierung KW - Reagenzien KW - Protein-Quantifizierung KW - Lanthaniden KW - Multiplexing PY - 2011 DO - https://doi.org/10.1007/s00216-011-5189-7 SN - 1618-2642 SN - 1618-2650 VL - 401 IS - 4 SP - 1203 EP - 1209 PB - Springer CY - Berlin AN - OPUS4-23949 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -