TY - GEN A1 - Ahrendt, H. A1 - Gesatzke, Roger A1 - Hahn, G. A1 - Herrmann, P. A1 - Julien, H. A1 - Karger, R. A1 - Kaufmann, M. A1 - Krebs, H.-J. A1 - Lucht, J. A1 - Müller, A. A1 - Müller, R. A1 - Vetter, B. T1 - Überdruckmessgeräte nach DIN EN 837 - Auswahl und Anwendung KW - Druckmessgerät KW - Sicherheit PY - 2007 SN - 978-3-410-16626-9 IS - 1. Auflage SP - 1 EP - 89 PB - Beuth CY - Berlin AN - OPUS4-15994 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Ebert, H.-P. A1 - Reichenauer, G. A1 - Brandt, R. A1 - Braxmeier, S. A1 - Bauer, T. A1 - Tamme, R. A1 - Langer, W. A1 - Hudler, B. A1 - Christ, M. A1 - Sextl, G. A1 - Müller, G. A1 - Helbig, U. A1 - Houbertz, R. A1 - Voigt, W. A1 - Schmidt, H. A1 - Zehl, T. A1 - Mach, Reinhard A1 - Maneck, Heinz-Eberhard A1 - Meyer-Plath, Asmus A1 - Oleszak, Franz A1 - Keuper, M. A1 - Reisert, M. A1 - Burkhardt, H. A1 - Günther, E. A1 - Mehling, H. T1 - Netzwerk zur Überwindung grundlegender Probleme bei der Entwicklung hocheffizienter Latentwärmespeicher auf Basis anorganischer Speichermaterialien KW - Latentwärmespeicher KW - Materialforschung KW - Plasmaverfahren KW - Graphit PY - 2008 SN - 978-3-00-024699-9 SP - 1 EP - 217 CY - Würzburg AN - OPUS4-18273 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Krumbholz, N. A1 - Jansen, A. A1 - Scheller, M. A1 - Müller-Wirts, T. A1 - Lübbecke, S. A1 - Holzwarth, R. A1 - Scheunemann, R. A1 - Wilk, R. A1 - Sartorius, B. A1 - Roehle, H. A1 - Stanze, D. A1 - Beckmann, Jörg A1 - von Chrzanowski, Lars A1 - Ewert, Uwe A1 - Koch, M. ED - Keith A. Krapels, ED - Neil A. Salmon, T1 - Handheld terahertz spectrometer for the detection of liquid explosives N2 - We present a handheld fiber-coupled terahertz spectrometer operating at a center wavelength of 1550 nm. The key elements are a fs-fiber laser, a fiber stretcher delay line and fiber-coupled antennas, which contain novel InAlAs-InGaAs multi layer chips. First experimental data obtained with this system demonstrates its great potential and robustness. In addition, we investigate different hazardous and harmless liquids in reflection geometry. These experiments show that liquids are in principle distinguishable by terahertz spectroscopy. Finally, first steps towards an algorithm that allows for an extraction of the liquids dielectric properties are discussed. The algorithm works for the analysis of reflection data even if the liquid is located inside a container. KW - Handheld terahertz spectrometer KW - Liquid explosives PY - 2009 DO - https://doi.org/10.1117/12.830381 SN - 0277-786X VL - 7485 SP - 748504-1 - 748504-12 AN - OPUS4-20268 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Faghani, A. A1 - Gholami, M. F. A1 - Trunk, M. A1 - Müller, J. A1 - Pachfule, P. A1 - Vogl, S. A1 - Donskyi, Ievgen A1 - Li, M. A1 - Nickl, Philip A1 - Shao, J. A1 - Huang, M. R. S. A1 - Unger, Wolfgang A1 - Arenal, R. A1 - Koch, C. T. A1 - Paulus, B. A1 - Rabe, J. P. A1 - Thomas, A. A1 - Haag, R. A1 - Adeli, M. T1 - Metal-Assisted and Solvent-Mediated Synthesis of Two-Dimensional Triazine Structures on Gram Scale N2 - Covalent triazine frameworks are an emerging material class that have shown promising performance for a range of applications. In this work, we report on a metal-assisted and solvent-mediated reaction between calcium carbide and cyanuric chloride, as cheap and commercially available precursors, to synthesize two-dimensional triazine structures (2DTSs). The reaction between the solvent, dimethylformamide, and cyanuric chloride was promoted by calcium carbide and resulted in dimethylamino-s-triazine intermediates, which in turn undergo nucleophilic substitutions. This reaction was directed into two dimensions by calcium ions derived from calcium carbide and induced the formation of 2DTSs. The role of calcium ions to direct the two-dimensionality of the final structure was simulated using DFT and further proven by synthesizing molecular intermediates. The water content of the reaction medium was found to be a crucial factor that affected the structure of the products dramatically. While 2DTSs were obtained under anhydrous conditions, a mixture of graphitic material/2DTSs or only graphitic material (GM) was obtained in aqueous solutions. Due to the straightforward and gram-scale synthesis of 2DTSs, as well as their photothermal and photodynamic properties, they are promising materials for a wide range of future applications, including bacteria and virus incapacitation. KW - XPS KW - Triazine KW - 2D PY - 2020 DO - https://doi.org/10.1021/jacs.0c02399 VL - 142 IS - 30 SP - 12976 EP - 12986 PB - ACS American Chemical Society AN - OPUS4-51203 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Abou-Ras, D. A1 - Caballero, R. A1 - Fischer, C.-H. A1 - Kaufmann, C.A. A1 - Lauermann, I. A1 - Mainz, R. A1 - Mönig, H. A1 - Schöpke, A. A1 - Stephan, C. A1 - Streeck, C. A1 - Schorr, S. A1 - Eicke, A. A1 - Döbeli, M. A1 - Gade, B. A1 - Hinrichs, J. A1 - Nunney, T. A1 - Dijkstra, H. A1 - Hoffmann, V. A1 - Klemm, D. A1 - Efimova, V. A1 - Bergmaier, A. A1 - Dollinger, G. A1 - Wirth, Thomas A1 - Unger, Wolfgang A1 - Rockett, A.A. A1 - Perez-Rodriguez, A. A1 - Alvarez-Garcia, J. A1 - Izquierdo-Roca, V. A1 - Schmid, T. A1 - Choi, P.-P. A1 - Müller, M. A1 - Bertram, F. A1 - Christen, J. A1 - Khatri, H. A1 - Collins, R.W. A1 - Marsillac, S. A1 - Kötschau, I. T1 - Comprehensive comparison of various techniques for the analysis of elemental distributions in thin films N2 - The present work shows results on elemental distribution analyses in Cu(In,Ga)Se2 thin films for solar cells performed by use of wavelength-dispersive and energy-dispersive X-ray spectrometry (EDX) in a scanning electron microscope, EDX in a transmission electron microscope, X-ray photoelectron, angle-dependent soft X-ray emission, secondary ion-mass (SIMS), time-of-flight SIMS, sputtered neutral mass, glow-discharge optical emission and glow-discharge mass, Auger electron, and Rutherford backscattering spectrometry, by use of scanning Auger electron microscopy, Raman depth profiling, and Raman mapping, as well as by use of elastic recoil detection analysis, grazing-incidence X-ray and electron backscatter diffraction, and grazing-incidence X-ray fluorescence analysis. The Cu(In,Ga)Se2 thin films used for the present comparison were produced during the same identical deposition run and exhibit thicknesses of about 2 µm. The analysis techniques were compared with respect to their spatial and depth resolutions, measuring speeds, availabilities, and detection limits. KW - Elemental distributions KW - Comparison KW - Depth profiling KW - Chemical mapping KW - Thin films KW - Solar cells KW - Chalcopyrite-type KW - Cu(In,Ga)Se2 PY - 2011 DO - https://doi.org/10.1017/S1431927611000523 SN - 1431-9276 SN - 1435-8115 VL - 17 IS - 5 SP - 728 EP - 751 PB - Cambridge University Press CY - New York, NY AN - OPUS4-24506 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wipfler, B. A1 - Machida, R. A1 - Müller, Bernd R. A1 - Beutel, R.G. T1 - On the head morphology of Grylloblattodea (insecta) and the systematic position of the order, with a new nomenclature for the head muscles of Dicondylia N2 - External and internal head structures of adults of Galloisiana yuasai (Grylloblattodea) are described. The results are compared with conditions found in representatives of other lower neopteran lineages, notably in Austrophasma and Karoophasma (both Mantophasmatodea). Sutures and ridges of the head capsule are discussed. A new nomenclature for head muscles is presented for the entire Dicondylia (= Zygentoma + Pterygota). Galloisiana (like its sister taxon Grylloblatta) is mostly characterized by plesiomorphic features, such as the largely unspecialized orthopteroid mouthparts, the multisegmented filiform antennae, the presence of trabeculae tentorii, the absence of muscles associated with the antennal ampullae, the presence of musculus stipitalis transversalis (0mx11) and the presence of musculus tentoriofrontalis anterior (0te2). Autapomorphies of Grylloblattodea are: (i) compound eyes composed of only 60 ommatidia or less; (ii) a lacinia with a proximal tooth; (iii) a rounded submentum; (iv) loss of musculus craniohypopharyngealis (0hy3); and (v) loss of musculus labroepipharyngealis (0lb5). The phylogenetic evaluation of 104 characters of the head yields a branching pattern with Grylloblattodea as a sister group of Mantophasmatodea in clade Xenonomia. Putative synapomorphies of both taxa are: (i) a distinct angle (more than 60°) between the submentum and the mentum; (ii) posteriorly oriented labial palpi; (iii) a flat and lobe-like hypopharynx with a suspensorium far ventrad of the anatomical mouth opening; (iv) loss of musculus tentorioparaglossalis (0la6); and (v) a connection between the antennal ampulla and the supraoesophageal ganglion containing nuclei. Xenonomia is placed in a clade with the two dictyopteran terminals. Another monophyletic group is Embioptera + Phasmatodea. Most branches of the single tree obtained in our analysis are weakly supported. The results clearly show that more data and a much broader taxon sampling are required to clarify the phylogenetic interrelationships of the lower neopteran orders. However, our results narrow down the spectrum of possible solutions, and represent a starting point for future phylogenetic analyses, with an extensive concatenated dataset. KW - X-ray computed tomography KW - Grylloblattodea KW - Dicondylia PY - 2011 DO - https://doi.org/10.1111/j.1365-3113.2010.00556.x SN - 0307-6970 VL - 36 IS - 2 SP - 241 EP - 266 PB - Blackwell CY - Oxford [u.a.] AN - OPUS4-23190 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Rack, A. A1 - Riesemeier, Heinrich A1 - Zabler, S. A1 - Weitkamp, T. A1 - Müller, Bernd R. A1 - Weidemann, Gerd A1 - Modregger, P. A1 - Banhart, J. A1 - Helfen, L. A1 - Danilewsky, A.N. A1 - Gräber, H.G. A1 - Heldele, R. A1 - Mayzel, B. A1 - Goebbels, Jürgen A1 - Baumbach, T. ED - Stuart R. Stock, T1 - The high-resolution synchrotron-based imaging stations at the BAMline (BESSY) and TopoTomo (ANKA) N2 - The BAMline at the BESSY light source in Berlin and the TopoTomo beamline at the ANKA synchrotron facility in Karlsruhe (both Germany) operate in the hard X-ray regime (above 6 keV) with similiar photon flux density. For typical imaging applications, a double multilayer monochromator or a filtered white beam is used. In order to optimise the field of view and the resolution of the available indirect pixel detectors, different optical systems have been installed, adapted, respectively, to a large field of view (macroscope) and to high spatial resolution (microscope). They can be combined with different camera systems, ranging from 16-bit dynamic range slow-scan CCDs to fast CMOS cameras. The spatial resolution can be brought substantially beyond the micrometer limit by using a Bragg magnifier. The moderate flux of both beamlines compared to other 3rd generation light sources is compensated by a dedicated scintillator concept. For selected applications, X-ray beam collimation has proven to be a reliable approach to increase the available photon flux density. Absorption contrast, phase contrast, holotomography and refraction-enhanced imaging are used depending on the application. Additionally, at the TopoTomo beamline digital white beam synchrotron topography is performed, using the digital X-ray pixel detectors installed. KW - Microtomography KW - Non-destructive evaluation KW - Coherent imaging KW - X-ray refraction KW - X-ray phase contrast KW - Synchrotron-CT KW - Synchrotron instrumentation KW - Scintillator KW - Bragg magnification KW - Holotomography KW - X-ray topography PY - 2008 DO - https://doi.org/10.1117/12.793721 SN - 0277-786X VL - 7078 SP - 70780X-1 - 70780X-9 AN - OPUS4-18296 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Seah, M.P. A1 - Spencer, S.J. A1 - Bensebaa, F. A1 - Vickridge, I. A1 - Danzebrink, H. A1 - Krumrey, M. A1 - Gross, Thomas A1 - Österle, Werner A1 - Wendler, E. A1 - Rheinländer, B. A1 - Azuma, Y. A1 - Kojima, I. A1 - Suzuki, N. A1 - Suzuki, M. A1 - Tanuma, S. A1 - Moon, D.W. A1 - Lee, H.J. A1 - Cho, H.M. A1 - Chen, H.Y. A1 - Wee, A. T. S. A1 - Osipowicz, T. A1 - Pan, J.S. A1 - Jordaan, W.A. A1 - Hauert, R. A1 - Klotz, U. A1 - van der Marel, C. A1 - Verheijen, M. A1 - Tamminga, Y. A1 - Jeynes, C. A1 - Bailey, P. A1 - Biswas, S. A1 - Falke, U. A1 - Nguyen, N.V. A1 - Chandler-Horowitz, D. A1 - Ehrstein, J.R. A1 - Muller, D. A1 - Dura, J.A. T1 - Critical review of the current status of thickness measurements for ultrathin SiO2 on Si - Part V: Results of a CCQM pilot study N2 - Results are reported from a pilot study under the Consultative Committee for Amount of Substance (CCQM) to compare measurements of and resolve any relevant measurement issues in, the amount of thermal SiO2 oxide on (100) and (111) orientation Si wafer substrates in the thickness range 1.5 - 8 nm. As a result of the invitation to participate in this activity, 45 sets of measurements have been made in different laboratories using 10 analytical methods: medium-energy ion scattering spectrometry (MEIS), nuclear reaction analysis (NRA), RBS, elastic backscattering spectrometry (EBS), XPS, SIMS, ellipsometry, grazing-incidence x-ray reflectrometry (GIXRR), neutron reflectometry and transmission electron microscopy (TEM). The measurements are made on separate sets of 10 carefully prepared samples, all of which have been characterised by a combination of ellipsometry and XPS using carefully established reference conditions and reference parameters. The results have been assessed against the National Physical Laboratory (NPL) data and all show excellent linearity. The remaining data sets correlate with the NPL data with average root-mean-square scatters of 0.15 nm, half being better than 0.1 nm and a few at or better than 0.05 nm. Each set of data allows a relative scaling constant and a zero thickness offset to be determined. Each method has an inherent zero thickness offset between 0 nm and 1 nm and it is these offsets, measured here for the first time, that have caused many problems in the past. There are three basic classes of offset: water and carbonadeous contamination equivalent to ~1 nm as seen by ellipsometry; adsorbed oxygen mainly from water at an equivalent thickness of 0.5 nm as seen by MEIS, NRA, RBS and possibly GIXRR; and no offset as seen by XPS using the Si 2p peaks. Each technique has a different uncertainty for the scaling constant and consistent results have been achieved. X-Ray photoelectron spectroscopy has large uncertainties for the scaling constant but a high precision and, critically, if used correctly, has zero offset. Thus, a combination of XPS and the other methods allows the XPS scaling constant to be determined with low uncertainty, traceable via the other methods. XPS laboratories returning results early were invited to test a new reference procedure. All showed very significant improvements. The reference attenuation lengths thus need scaling by 0.986 ± 0.009 (at an expansion factor of 2) deduced from the data for the other methods. Several other methods have small offsets and, to the extent that these can be shown to be constant or measurable, then these methods will also show low uncertainty. Recommendations are provided for parameters for XPS, MEIS, RBS and NRA to improve their accuracy. KW - Calibration KW - Ellipsometry KW - GIXRR KW - Interlaboratory study KW - MEIS KW - Neutron reflectometry KW - NRA KW - RBS KW - Silicon dioxide KW - SIMS KW - XPS PY - 2004 DO - https://doi.org/10.1002/sia.1909 SN - 0142-2421 SN - 1096-9918 VL - 36 IS - 9 SP - 1269 EP - 1303 PB - Wiley CY - Chichester AN - OPUS4-5549 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - RPRT A1 - Seah, M.P. A1 - Spencer, S.J. A1 - Bensebaa, F. A1 - Vickridge, I. A1 - Danzebrink, H. A1 - Krumrey, M. A1 - Gross, Thomas A1 - Österle, Werner A1 - Wendler, E. A1 - Rheinländer, B. A1 - Azuma, Y. A1 - Kojima, I. A1 - Suzuki, N. A1 - Suzuki, M. A1 - Tanuma, S. A1 - Moon, D.W. A1 - Lee, H.J. A1 - Cho, H.M. A1 - Chen, H.Y. A1 - Wee, A. T. S. A1 - Osipowicz, T. A1 - Pan, J.S. A1 - Jordaan, W.A. A1 - Hauert, R. A1 - Klotz, U. A1 - van der Marel, C. A1 - Verheijen, M. A1 - Tamminga, Y. A1 - Jeynes, C. A1 - Bailey, P. A1 - Biswas, S. A1 - Falke, U. A1 - Nguyen, N.V. A1 - Chandler-Horowitz, D. A1 - Ehrstein, J.R. A1 - Muller, D. A1 - Dura, J.A. T1 - Ultra-thin SiO2 on Si, Part V: Results of a CCQM Pilot Study of Thickness Measurements KW - SiO2 KW - Thin films KW - Thickness KW - XPS KW - Ellipsometry KW - TEM PY - 2003 SN - 1473-2734 SP - 57 pages AN - OPUS4-4118 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bernhardt, R. A1 - Scharnweber, D. A1 - Müller, B. A1 - Thurner, P. A1 - Schliephake, K. A1 - Wyss, P. A1 - Beckmann, F. A1 - Goebbels, Jürgen A1 - Worch, H. T1 - Comparison of microfocus- and synchrotron X-ray tomography for the analysis of osteointegration around T16AL4V-implants N2 - Micro-computed tomography (µCT) provides quantitative three-dimensional information of bone around titanium implants similar to classical histology. The study, based on an animal model, using cuboid-shaped biofunctionalised Ti6Al4V implants with surrounding bone after 4 weeks, is performed using 3 µCT-systems with X-ray tubes, one synchrotron-radiation-based µCT-system (SRµCT), and classical histology. Although the spatial resolution of the µCTsystems is comparable, only the results of SRµCT agree with results of classical histology. The X-ray tube sources give rise to huge artefacts in the tomograms (interface scattering, beam hardening), which impaired the quantitative analysis of bone up to about 200 µm from the implant surface. Due to the non-destructive character of µCT the specimens can be subsequently examined by classical histology without restriction. The quantitative comparison of bone formation uncovers the strong dependence of the detected amount of newly formed bone from the selected slice. This implies the necessity of 3D analysis. SRµCT and classical histology prove that surface modifications of the titanium implant significantly influence the bone formation. Using SRµCT, the preparation artefacts due to cutting and polishing are excluded. KW - X-ray micro computed tomography KW - Comparison of microfocus and synchrotron radiation KW - Osteointegration KW - Surface modification of titanium implants KW - Histology KW - Bone segmentation KW - Quantification of bone formation PY - 2004 UR - http://www.ecmjournal.org/journal/papers/vol007/vol007a05.php SN - 1473-2262 VL - 7 SP - 42 EP - 51 PB - Univ. of Wales CY - Aberystwyth, Wales AN - OPUS4-5600 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Müller, Bernd R. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Hamm, B. A1 - Rogalla, P. A1 - Diederichs, G. A1 - Issever, A.S. T1 - First Synchrotron Refraction CT of Cartilage KW - X-ray Refraction KW - Computed Tomography KW - DEI KW - Cartilage PY - 2008 UR - http://www.helmholtz-berlin.de/media/media/oea/web/pr_webseite/druckschriften/berichte/bessy/annual_report_2007-v2.pdf#page=292 SN - 0179-4159 SP - 292 EP - 296 PB - Berliner Elektronenspeicherring-Gesellschaft für Synchrotronstrahlung CY - Berlin AN - OPUS4-17661 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Müller, Bernd R. A1 - Soares, A.P. A1 - Kupsch, Andreas A1 - Baum, D. A1 - Hesse, B. A1 - Zaslansky, P. T1 - Untersuchung der Integrität von glasfaserverstärkten Zahnstiften mittels Synchrotron-Röntgenrefraktion N2 - Die Integrität der Verstärkungsfasern in Komposit-Zahnstiften ist entscheidend für die Biegefestigkeit und die langfristige Haftung am Zement in den Wurzelkanälen. Es wurde vermutet, dass die Integrität von glasfaserverstärkten Zahnstiften durch das Beschleifen während der zahnmedizinischen Behandlung beeinträchtigt wird. Eine Beschädigung der Fasern führt zu einer erheblichen strukturellen Schwächung über den gesamten Stiftdurchmesser. Glasfragmente, die durch den Kontakt mit dem Zahnbohrer entstehen, können sich vom Stift lösen und die Haftfähigkeit erheblich verringern. Mit Hilfe hochauflösender Synchrotron-Röntgen-Refraktions-Radiographie (SXRR) konnte das Ausmaß der Schäden zuverlässig identifiziert und charakterisiert werden. Dazu wurden die Glasfaserstifte sowohl im Herstellungszustand als auch nach der Bearbeitung mit einem Diamantbohrer untersucht. Die Datensätze wurden zur Visualisierung und Quantifizierung der morphologischen Charakteristika intakter und durch das Beschleifen beschädigter Regionen analysiert. Sie zeigen Schäden im bearbeiteten Bereich (z. B. Brüche, Splitter und Risse) sowie herstellungsbedingte Inhomogenitäten der Fasern mit einer signifikanten Zunahme der inneren Oberflächen in Probenregionen, die durch das Beschleifen beschädigt wurden. T2 - DGZfP Jahrestagung 2022 CY - Kassel, Germany DA - 23.05.2022 KW - Röntgen-Refraktion KW - Verbundwerkstoffe KW - Zahnstifte PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-549231 SP - 1 EP - 7 AN - OPUS4-54923 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wipfler, B. A1 - Bradler, S. A1 - Büsse, S. A1 - Hammel, J. A1 - Müller, Bernd R. A1 - Pass, G. T1 - Evolutionary morphology of the antennal heart in stick and leaf insects (Phasmatodea) and webspinners (Embioptera) (Insecta: Eukinolabia) N2 - The morphology of the antennal hearts in the head of Phasmatodea and Embioptera was investigated with particular reference to phylogenetically relevant key taxa. The antennal circulatory organs of all examined species have the same basic construction: they consist of antennal vessels that are connected to ampullae located in the head near the antenna base. The ampullae are pulsatile due to associated muscles, but the points of attachment differ between the species studied. All examined Phasmatodea species have a Musculus (M.) interampullaris which extends between the two ampullae plus a M. ampulloaorticus that runs from the ampullae to the anterior end of the aorta; upon contraction, all these muscles dilate the lumina of both ampullae at the same time. In Embioptera, only the australembiid Metoligotoma has an M. interampullaris. All other studied webspinners instead have a M. ampullofrontalis which extends between the ampullae and the frontal region of the head capsule; these species do not have M. ampulloaorticus. Outgroup comparison indicates that an antennal heart with a M. interampullaris is the plesiomorphic character state among Embioptera and the likely ground pattern of the taxon Eukinolabia. Antennal hearts with a M. ampullofrontalis represent a derived condition that occurs among insects only in some embiopterans. These findings help to further clarify the controversially discussed internal phylogeny of webspinners by supporting the view that Australembiidae are the sister group of the remaining Embioptera. KW - Phylogeny KW - Polyneoptera KW - Metoligotoma PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-527795 DO - https://doi.org/10.1007/s00435-021-00526-4 SN - 1432-234X VL - 140 IS - 3 SP - 331 EP - 340 PB - Springer AN - OPUS4-52779 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bertovic, Marija A1 - Calmon, P. A1 - Carter, L. A1 - Fischer, J. A1 - Forsyth, D. A1 - Holstein, R. A1 - McGrath, B. A1 - Müller, Christina A1 - Pavlovic, Mato A1 - Ronneteg, U. A1 - Rummel, W. A1 - Schubert, F. A1 - Selby, G. T1 - Summary of the "open space technology discussions" on reliability of NDE N2 - Since the beginnings of the European American Workshops (EAW) in 1997, the aim was to gather the experts in NDE reliability and discuss burning topics with the aim of identifying crucial problems and suggesting ways to move forward. This was usually achieved during the so-called break-out sessions, in which predetermined topics were discussed. During the 5th EAW, held in Berlin in 2013, this approach was replaced by an Open Space Technology (OST) approach. The benefit of this approach is seen in the freedom of topic choices, i. e., the topics are not predetermined but rather arise at that moment in that space and by the participants’ choice. The following topics arose: new reliability methods (Bayesian, MAPOD, …), structural health monitoring, definition of requirements of NDE by customer versus provider, what value of POD is good enough?, human factors, manual versus automated inspection, and basic concepts of reliability of NDE. The participants were encouraged to walk from one session to another and openly express their opinions. These were in the end summarized by a chosen group of moderators and presented in this paper. N2 - Seit den Anfängen der europäischen amerikanischen Workshops (EAW) im Jahr 1997 war es das Ziel, Experten auf dem Gebiet der ZfP-Zuverlässigkeit zusammenzuführen und aktuelle Themen zu diskutieren, um wichtige Probleme zu identifizieren und Wege für deren Lösung vorzuschlagen. Dies wurde in der Regel während der sogenannten „Break-out Sessions“ erreicht, in denen vorgegebene Themen diskutiert wurden. Während des 5. EAW, der in Berlin im Jahr 2013 stattfand, wurde dieser Ansatz durch einen Open Space Technology (OST) Ansatz ersetzt. Open Space ist eine Methode der Gruppenmoderation, die sehr gut geeignet ist, um neue Ideen zu entwickeln und selbstständiges Arbeiten zu fördern, d. h. die Themen werden nicht vorgegeben, sondern ergeben sich in diesem Moment in diesem Raum und durch die Wahl der Teilnehmer. Die folgenden Themen wurden herausgearbeitet: neue Zuverlässigkeitsmethoden (Bayes, MAPOD, ...…), Structural Health Monitoring, Definition von Anforderungen der Kunden gegenüber den ZfP-Anbietern, Welcher Wert der POD ist gut genug?, der Einfluss menschlicher Faktoren, manuelle gegenüber automatisierte Prüfung, sowie Grundkonzepte der ZfP-Zuverlässigkeit. Die Teilnehmer wurden aufgefordert, von einer Sitzung zur anderen zu wechseln und offen ihre Meinung zu äußern. Diese Meinungen wurden am Ende von einer ausgewählten Gruppe von Moderatoren zusammengefasst und werden in diesem Beitrag vorgestellt. KW - NDE reliability KW - POD KW - Bayesian approach KW - Structural health monitoring KW - Human factors KW - Open space technology PY - 2014 UR - http://www.hanser-elibrary.com/doi/pdf/10.3139/120.110604 DO - https://doi.org/10.3139/120.110604 SN - 0025-5300 VL - 56 IS - 7-8 SP - 602 EP - 606 PB - Hanser CY - München AN - OPUS4-31269 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Bertovic, Marija A1 - Calmon, P. A1 - Carter, L. A1 - Fisher, J. A1 - Forsyth, D. A1 - Holstein, R. A1 - McGrath, B. A1 - Müller, Christina A1 - Pavlovic, Mato A1 - Ronneteg, U. A1 - Rummel, W. A1 - Schubert, F. A1 - Selby, G. T1 - Summary of the open space technology discussions T2 - 5th European-American workshop on reliability of NDE CY - Berlin, Germany DA - 2013-10-07 PY - 2013 SN - 978-3-940283-53-5 IS - DGZfP-BB 144 SP - 1 EP - 7(?) CY - Berlin AN - OPUS4-31271 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nellesen, J. A1 - Laquai, René A1 - Müller, Bernd R. A1 - Kupsch, Andreas A1 - Hentschel, M. P. A1 - Anar, N. B. A1 - Soppa, E. A1 - Tillmann, W. A1 - Bruno, Giovanni T1 - In situ analysis of damage evolution in an Al/Al2O3 MMC under tensile load by synchrotron X-ray refraction imaging N2 - The in situ analysis of the damage evolution in a metal Matrix composite (MMC) using synchrotron X-ray refraction radiography (SXRR) is presented. The investigated material is an Al alloy (6061)/10 vol% Al2O3 MMC after T6 heat treatment. In an interrupted tensile test the gauge section of dog bone-shaped specimens is imaged in different states of tensile loading. On the basis of the SXRR images, the relative change of the specific surface (proportional to the amount of damage) in the course of tensile loading was analyzed. It could be shown that the damage can be detected by SXRR already at a stage of tensile loading, in which no Observation of damage is possible with radiographic absorption-based imaging methods. Moreover, the quantitative analysis of the SXRR images reveals that the amount of damage increases homogeneously by an average of 25% with respect to the Initial state. To corroborate the experimental findings, the damage distribution was imaged in 3D after the final tensile loading by synchrotron X-ray refraction computed tomography (SXRCT) and absorption-based synchrotron X-ray computed tomography (SXCT). It could be evidenced that defects and damages cause pronounced indications in the SXRCT images. KW - Composite materials KW - Defects KW - Micro analysis PY - 2018 DO - https://doi.org/10.1007/s10853-017-1957-x SN - 0022-2461 SN - 1573-4803 VL - 53 IS - 8 SP - 6021 EP - 6032 PB - Springer US AN - OPUS4-44241 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hoesl, Simone A1 - Neumann, B. A1 - Techritz, Sandra A1 - Sauter, G. A1 - Simon, R. A1 - Schlüter, H. A1 - Linscheid, M. W. A1 - Theruing, F. A1 - Müller, Larissa A1 - Jakubowski, Norbert T1 - Internal standardization of LA-ICP-MS immunoimaging via printing of universal metal spiked inks onto tissue sections N2 - Formalin-fixed paraffin-embedded (FFPE) specimen from biopsy materials are a widespread sample format for pathologists and medical researchers. Pathologists are archiving vast numbers of FFPE samples which can be stored for decades. Conventional immunohistochemical staining (IHC) of biomarkers on FFPE tissue sections is one of the most important analytical techniques for cancer diagnosis and pathology in general. However standardization for IHC samples and quality management is tedious and differs significantly from clinic to clinic. Combining established IHC staining strategies with modern mass spectrometry mediated methods would increase it`s potential and enable access of large FFPE archives for multiplexed quantitation purposes. In this work element mass spectrometry and a new ink-jet printed internal standardization approach was successfully combined with IHC staining to facilitate quantitative multiplex assays for archived FFPE samples. The printing strategy improves elemental image resolution and reproducibility of paraffin embedded breast cancer tissue sections in laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) using conventional IHC staining as a model system to investigate the new capabilities of this technique. For the internal standardization we applied a conventional CD-ink-jet printer to print a metal spiked ink onto the top of thin layer tissue sections with constant density. Printing was carried out in a direct comparison to an iodination of the tissue section as previously described as an alternative standardization method. The use of the printed internal standard allowed correction of the fluctuation during the laser ablation process and compensated instrumental drift effects. Mediated by the ink correction approach we achieved better signal-to-background-ratios (SBR) of 74 and better spatial resolution of 30 µm compared to iodination (SBR=23). This improved performance was demonstrated on tumorous areas in FFPE breast cancer tissue sections and allowing detection of Her-2 in tumorous areas of this tissue with significantly improved contrast. KW - Internal standardization KW - LA-ICP-MS KW - Immuno imaging PY - 2016 DO - https://doi.org/10.1039/c5ja00409h SN - 0267-9477 SN - 1364-5544 VL - 31 IS - 3 SP - 801 EP - 808 AN - OPUS4-35711 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Soares, A.P. A1 - Baum, D. A1 - Hesse, B. A1 - Kupsch, Andreas A1 - Müller, Bernd R. A1 - Zaslansky, P. T1 - Scattering and phase-contrast X-ray methods reveal damage to glass fibers in endodontic posts following dental bur trimming N2 - Objectives. There is concern that the integrity of fiberglass dental posts may be affected by chairside trimming during treatment. We hypothesize that hard X-ray methods of phase contrast-enhanced micro-CT (PCE-CT) and synchrotron based X-ray refraction (SXRR) can reliably identify and help characterize the extent of damage. Methods. Fiberglass posts were imaged both as manufactured and following trimming with a diamond bur. Each of the posts was imaged by SXRR and by PCE-CT. Datasets from PCE-CT were used to visualize and quantify 2D and 3D morphological characteristics of intact and of damage-affected regions caused by trimming. Results. The SXRR images revealed fiber inhomogeneities from manufacturing with a significant increase in internal surfaces in sample regions corresponding to damage from trimming. PCE-CT volumes unveiled the micromorphology of single fibers in the posts and some damage in the trimmed area (e.g. fractures, splinters and cracks). Area, perimeter, circularity, roundness, volume and thickness of the glass fibers in the trimmed area were statistically different from the control (p < 0.01). Significance. The integrity of single fibers in the post is critical for bending resistance and for long-term adhesion to the cement in the root canals. Damage to the fibers causes substantial structural weakening across the post diameter. Glass fragments produced due to contact with the dental bur may separate from the post and may significantly reduce bond capacity. The above mentioned synchrotron-based imaging techniques can further facilitate assessment of the structural integrity and the appearance of defects in posts (e.g. after mechanical load). KW - Fiberglass composite KW - Fiber reinforced dental post KW - X-ray refraction KW - Phase contrast-enhanced micro-CT KW - Non-destructive testing PY - 2021 DO - https://doi.org/10.1016/j.dental.2020.10.018 SN - 0109-5641 VL - 37 IS - 2 SP - 201 EP - 211 PB - Elsevier Inc. AN - OPUS4-52071 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Silvestroni, L. A1 - Kupsch, Andreas A1 - Müller, B. R. A1 - Ulbricht, Alexander A1 - Wieder, Frank A1 - Fritsch, Tobias A1 - Sciti, D. A1 - Bruno, Giovanni T1 - Determination of short carbon fiber orientation in zirconium diboride ceramic matrix composites N2 - In fiber-reinforced components, the fiber alignment and orientation have paramount influence on the thermomechanical properties of the resulting composite, for both short and continuous fiber. Here we present the case of an ultra-refractory matrix intended for extreme environment applications, ZrB2, reinforced with 20 vol% and 50 vol% short carbon fibers. In both cases, fibers tend to align perpendicular to the uniaxial pressure applied during shaping and sintering of a pellet, although the fiber tilt across the pellet thickness is difficult to determine. Moreover, for high volume fractions of reinforcement, the spatial distribution of the fibers is heterogeneous and tends to have domains of preferential orientations. We compare the information on the fiber distribution as collected by scanning electron microscopy images, X-ray computed tomography and synchrotron X-ray refraction radiography (SXRR). The three techniques prove to be complementary. Importantly, we demonstrate that SXRR yields the most statistically significant information due to the largest field of view, yet with a sensitivity down to the nanometer, and that can be successfully applied also to heavy matrix materials, such as zirconium boride. KW - Ceramic matrix composites KW - Synchrotron X-ray refraction radiography KW - X-ray computed tomography KW - Scanning electron microscopy KW - High-temperature ceramics PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-597712 DO - https://doi.org/10.1016/j.jeurceramsoc.2024.02.048 SN - 0955-2219 VL - 44 IS - 8 SP - 4853 EP - 4862 PB - Elsevier Ltd. CY - Amsterdam AN - OPUS4-59771 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, W. A1 - Schweins, R. A1 - Nöcker, B. A1 - Kohlbrecher, J. A1 - Smales, Glen Jacob A1 - Huber, K. T1 - Comparative study of the co-assembly behaviour of 3-chloro-4-hydroxy-phenylazo dyes with DTAB N2 - The co-assembly of three one-fold negatively charged 3-chloro-4-hydroxy-phenylazo dyes (Yellow, Blue and Red) with the cationic surfactant dodecyltrimethylammoniumbromide (DTAB) was studied to probe dye–DTAB binding stoichiometry and assembly morphology. For each dye, phase separation was observed above a given dye : DTAB ratio with the ratio depending on the dye. While Yellow and DTAB showed liquid/liquid phase separation above Yellow : DTAB = 1 : 1.67, crystalline dye–DTAB complexes were observed for Blue–DTAB and Red–DTAB above Blue : DTAB = 1 : 2.56 and Red : DTAB = 1 : 2.94 respecively. In homogeneous solution, UV/vis spectroscopic investigations suggest stochiometries of Yellow : DTAB = 1 : 2, Blue : DTAB = 1 : 3 and Red : DTAB = 1 : 4. It was concluded, that Yellow exhibits the highest dye : DTAB binding stoichiometry in both, dye–surfactant complexes in the 2-phase region and in solution, whereas the lowest dye : DTAB binding stoichiometry was observed for Red–DTAB in both cases. The observed stoichiometries are inversely correlated to the impact dye addition has on the morphology of DTAB micelles. Generally, addition of dye to DTAB micelles leads to a reduction in spontaneous curvature of these micelles and to the formation of triaxial ellipsoidal or cylindrical micelles from oblate ellipsoidal DTAB micelles. At a DTAB concentration of 30 mM and a dye concentration of 5 mM, this effect was most pronounced for Red and least pronounced for Yellow, whilst Blue showed an intermediate effect. KW - Dye KW - DTAB KW - SAXS KW - Small-angle X-ray scattering KW - X-ray scattering KW - Data analysis KW - Micelle PY - 2023 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-576978 DO - https://doi.org/10.1039/D3SM00501A SN - 1744-683X VL - 19 IS - 24 SP - 4588 EP - 4598 PB - Royal Society of Chemistry AN - OPUS4-57697 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Bauer, L.J. A1 - Wieder, Frank A1 - Truong, V. A1 - Förste, F. A1 - Wagener, Y. A1 - Jonas, A. A1 - Praetz, S: A1 - Schlesiger, C. A1 - Kupsch, Andreas A1 - Müller, B.R. A1 - Kanngießer, B. A1 - Zaslansky, P. A1 - Mantouvalou, I. T1 - Absorption Correction for 3D Elemental Distributions of Dental Composite Materials Using Laboratory Confocal Micro-X-ray Fluorescence Spectroscopy N2 - Confocal micro-X-ray fluorescence (micro-XRF) spectroscopy facilitates three-dimensional (3D) elemental imaging of heterogeneous samples in the micrometer range. Laboratory setups using X-ray tube excitation render the method accessible for diverse research fields but interpretation of results and quantification remain challenging. The attenuation of X-rays in composites depends on the photon energy as well as on the composition and density of the material. For confocal micro-XRF, attenuation severely impacts elemental distribution information, as the signal from deeper layers is distorted by superficial layers. Absorption correction and quantification of fluorescence measurements in heterogeneous composite samples have so far not been reported. Here, an absorption correction approach for confocal micro-XRF combining density information from microcomputed tomography (micro-CT) data with laboratory X-ray absorption spectroscopy (XAS) and synchrotron transmission measurements is presented. The energy dependency of the probing volume is considered during the correction. The methodology is demonstrated on a model composite sample consisting of a bovine tooth with a clinically used restoration material. KW - Micro X-ray fluorescence spectroscopy KW - Dental composite materials KW - Computed tomography KW - Absorption correction PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-601630 DO - https://doi.org/10.1021/acs.analchem.4c00116 SN - 0003-2700 SN - 1520-6882 VL - 96 IS - 21 SP - 8441 EP - 8449 PB - American Chemical Society Publications CY - Washington, DC AN - OPUS4-60163 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Issever, A.S. A1 - Diederichs, G. A1 - Majumdar, S. A1 - Rogalla, P. A1 - Hamm, B.K. A1 - Lange, Axel A1 - Harwardt, Michael A1 - Hentschel, Manfred P. A1 - Müller, Bernd R. T1 - Analyser-based tomography images of cartilage N2 - Analyser-based imaging expands the performance of X-ray imaging by utilizing not only the absorption properties of X-rays but also the refraction and scatter rejection (extinction) properties. In this study, analyser-based computed tomography has been implemented on imaging an articular cartilage sample, depicting substructural variations, without overlay, at a pixel resolution of 3.6 µm. KW - Cartilage KW - Analyser-based imaging KW - Computed tomography PY - 2008 DO - https://doi.org/10.1107/S0909049508014829 SN - 0909-0495 SN - 1600-5775 VL - 15 IS - Part 5 SP - 525 EP - 527 PB - Blackwell Publishing CY - Oxford AN - OPUS4-17852 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Reveron, H. A1 - Serrano-Munoz, Itziar A1 - Kupsch, Andreas A1 - Müller, B.R. A1 - Chevalier, J. A1 - Bruno, Giovanni T1 - Transformation-induced plasticity in zirconia during tensile loading: A combined microscopy and synchrotron X-ray refraction study N2 - The stress-induced tetragonal to monoclinic (t-m) zirconia phase transformation can provide a certain degree of plasticity to Ceria-stabilized (Ce-TZP) zirconia-based composites. Characterizing and monitoring this phase transition on a millimeter-size range, within the bulk and in-situ remains a challenge. In this work, the mechanical behavior of Ce-TZP based composite was studied in tension, combining microscopy and synchrotron Xray refraction techniques. In contrast with microscopy methods, which only provide surface information, X-ray refraction radiography (SXRR) allowed the visualization of all the transformation bands, over the entire length and thickness of tested specimens, opening up new avenues for in-situ stress-induced t-m transformation studies. KW - Zirconia KW - Ceria KW - Composite KW - Phase transformation KW - Plasticity KW - Synchrotron X-ray refraction PY - 2024 DO - https://doi.org/10.1016/j.matlet.2024.136445 SN - 0167-577X SN - 1873-4979 VL - 366 SP - 1 EP - 4 PB - Elsevier Ltd. CY - Amsterdam AN - OPUS4-59977 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, R.H. A1 - Runge, S. A1 - Ravelli, V. A1 - Mehnert, W. A1 - Thünemann, Andreas A1 - Souto, E.B. T1 - Oral bioavailability of cyclosporine: Solid lipid nanoparticles (SLN®) versus drug nanocrystals N2 - For the development of an optimized oral formulation for cyclosporine A, 2% of this drug has been formulated in solid lipid nanoparticles (SLN™, mean size 157 nm) and as nanocrystals (mean size 962 nm). The encapsulation rate of SLN was found to be 96.1%. Nanocrystals are composed of 100% of drug. For the assessment of the pharmacokinetic parameters the developed formulations have been administered via oral route to three young pigs. Comparison studies with a commercial Sandimmun Neoral/Optoral® used as reference have been performed. The blood profiles observed after oral administration of the commercial microemulsion Sandimmun® revealed a fast absorption of drug leading to the observation of a plasma peak above 1000 ng/ml within the first 2 h. For drug nanocrystals most of the blood concentrations were in the range between 30 and 70 ng/ml over a period of 14 h. These values were very low, showing huge differences between the measuring time points and between the tested animals. On the contrary, administration of cyclosporine-loaded SLN led to a mean plasma profile with almost similarly low variations in comparison to the reference microemulsion, however with no initial blood peak as observed with the Sandimmun Neoral/Optoral®. Comparing the area under the curves (AUC) obtained with the tested animals it could be stated that the SLN™ formulation avoids side effects by lacking blood concentrations higher than 1000 ng/ml. In this study it has been proved that using SLN™ as a drug carrier for oral administration of cyclosporine A a low variation in bioavailability of the drug and simultaneously avoiding the plasma peak typical of the first Sandimmun® formulation can be achieved. KW - Solid lipid nanoparticles KW - SLN KW - Drug nanocrystals KW - Sandimmun Neoral/Optoral KW - Oral administration PY - 2006 DO - https://doi.org/10.1016/j.ijpharm.2006.02.045 SN - 0378-5173 SN - 1873-3476 VL - 317 IS - 1 SP - 82 EP - 89 PB - Elsevier CY - Amsterdam AN - OPUS4-12464 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Müller, R.H. A1 - Runge, S.A. A1 - Ravelli, V. A1 - Thünemann, Andreas A1 - Mehnert, W. A1 - Souto, E.B. T1 - Cyclosporine-loaded solid lipid nanoparticles (SLN): Drug-lipid physicochemical interactions and characterization of drug incorporation N2 - Solid lipid nanoparticles (SLN) were produced loaded with cyclosporine A in order to develop an improved oral formulation. In this study, the particles were characterized with regard to the structure of the lipid particle matrix, being a determining factor for mode of drug incorporation and drug release. Differential scanning calorimetry (DSC) and wide-angle X-ray scattering (WAXS) measurements were employed for the analysis of the polymorphic modifications and mode of drug incorporation. Particles were produced using Imwitor®900 as lipid matrix (the suspension consisted of 10% particles, 8% Imwitor®900, 2% cyclosporine A), 2.5% Tagat S, 0.5% sodium cholate and 87% water. DSC and WAXS were used to analyse bulk lipid, bulk drug, drug incorporated in the bulk and unloaded and drug-loaded SLN dispersions. The processing of the bulk lipid into nanoparticles was accompanied by a polymorphic transformation from the ß to the α-modification. After production, the drug-free SLN dispersions converted back to ß-modification, while the drug-loaded SLN stayed primarily in α-modification. After incorporation of cyclosporine A into SLN, the peptide lost its crystalline character. Based on WAXS data, it could be concluded that cyclosporine is molecularly dispersed in between the fatty acid chains of the liquid-crystalline α-modification fraction of the loaded SLN. KW - Solid lipid nanoparticles KW - Cyclosporine A KW - Characterization KW - Oral bioavailability KW - Lipid polymorphism PY - 2008 DO - https://doi.org/10.1016/j.ejpb.2007.07.006 SN - 0939-6411 SN - 1873-3441 VL - 68 IS - 3 SP - 535 EP - 544 PB - Elsevier CY - Amsterdam AN - OPUS4-17534 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -