TY - CONF A1 - Kern, Simon A1 - Guhl, Svetlana A1 - Meyer, Klas A1 - Paul, Andrea A1 - Wander, Lukas A1 - Gräßer, Patrick A1 - Maiwald, Michael T1 - Design and Validation of a Compact NMR Analyser N2 - Monitoring chemical reactions is the key to chemical process control. Today, mainly optical online methods are applied. NMR spectroscopy has a high potential for direct loop process control. Compact NMR instruments based on permanent magnets are robust and relatively inexpensive analysers, which feature advantages like low cost, low maintenance, ease of use, and cryogen-free operation. Instruments for online NMR measurements equipped with a flow-through cell, possessing a good signal-to-noise-ratio, sufficient robustness, and meeting the requirements for integration into industrial plants (i.e., explosion safety and fully automated data analysis) are currently not available off the rack. Intensified continuous processes are in focus of current research. Flexible (modular) chemical plants can produce different products using the same equipment with short down-times between campaigns and quick introduction of new products to the market. In continuous flow processes online sensor data and tight closed-loop control of the product quality are mandatory. If these are not available, there is a huge risk of producing large amounts of out-of-spec (OOS) products. This is addressed in the European Unionʼs Research Project CONSENS (Integrated Control and Sensing) by development and integration of smart sensor modules for process monitoring and control within such modular plant setups. The presented NMR module is provided in an explosion proof housing of 57 x 57 x 85 cm module size and involves a compact 43.5 MHz NMR spectrometer together with an acquisition unit and a programmable logic controller for automated data preparation (phasing, baseline correction) and evaluation. Indirect Hard Modeling (IHM) was selected for data analysis of the low-field NMR spectra. A set-up for monitoring continuous reactions in a thermostated 1/8” tubular reactor using automated syringe pumps was used to validate the IHM models by using high-field NMR spectroscopy as analytical reference method. T2 - 4th European Conference on Process Analytics and Control Technology (EuroPACT 2017) CY - Potsdam, Germany DA - 10.05.2017 KW - Prozessanalytik KW - Reaction Monitoring KW - Online NMR Spectrsocopy KW - Process Analytical Technology KW - Industrie 4.0 KW - EuroPACT PY - 2017 SP - 72 EP - 73 CY - Frankfurt a. M. AN - OPUS4-40229 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Paul, Andrea A1 - Müller, D. A1 - Esche, E. A1 - Wozny, G. A1 - Maiwald, Michael T1 - Chemometric modeling of on-line Raman spectra from miniplant operation N2 - The project InPROMPT aims to establish a robust hydroformylation reaction process of the alkene n-dodecene to the aldehyde n-tridecanal using a rhodium complex as catalyst in the presence of syngas. This industrial relevant production process demands further research for optimization and expansion. For that purpose, the fiber optic coupled probe of a process Raman spectrometer is directly introduced in the product stream, which enables the recording of spectra within short control intervals. T2 - 10. Kolloquium Arbeitskreis Prozessanalytik CY - Gerlingen, Germany DA - 25.11.2014 KW - Reaction monitoring KW - Chemometrics KW - Raman spectroscopy KW - Hydroformylation PY - 2014 UR - http://arbeitskreis-prozessanalytik.de/images/stories/Veranstaltungen/Kolloquien/10_kolloquium_2014/tagungsband_10_kolloquium_ak_prozessanalytik_2014_hq-druck_f.pdf SP - P12, 34 EP - 34 PB - BAM Bundesanstalt für Materialforschung und -prüfung CY - Berlin AN - OPUS4-38361 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Paul, Andrea A1 - Ruiken, J.-P. A1 - Meyer, Klas A1 - Westad, Frank A1 - Illner, M. A1 - Müller, D. A1 - Wozny, G. A1 - Maiwald, Michael T1 - Online spectroscopy in microemulsions – A process analytical approach for hydroformylation miniplant II - Calibration and prediction by Raman spectra N2 - The Collaborative Research Center InPROMPT aims to establish a novel process concept for the hydroformylation of long-chained olefins, using a rhodium complex as catalyst in the presence of syngas. Recently, the hydroformylation in micro-emulsions, which allows for the efficient recycling of the expensive rhodium catalyst, was found to be feasible. However, the temperature and concentration sensitive multi-phase system demands a continuous observation of the reaction to achieve an operational and economically feasible plant operation. For that purpose, we tested the potential of both NMR and Raman spectroscopy for process control assistance. The lab-scale experiments were supported by sampling for off-line GC-analysis as reference analytics. The results of the NMR experiments will be part of another contribution. T2 - 11. Kolloquium Arbeitskreis Prozessanalytik CY - Wien, Austria DA - 30.11.2015 KW - Prozessanalytik KW - Process analytical technology KW - Prozess-Spektroskopie KW - Emulsions KW - Hydroformylation KW - Reaction monitoring KW - Raman spectroscopy PY - 2015 SP - 66 EP - 67 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-38846 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Meyer, Klas A1 - Ruiken, J.-P. A1 - Illner, M. A1 - Müller, D. A1 - Esche, E. A1 - Paul, Andrea A1 - Wozny, G. A1 - Maiwald, Michael T1 - Online spectroscopy in microemulsions – A process analytical approach for hydroformylation miniplant I – Experimental setup and NMR reaction monitoring N2 - Hydroformylation represents an important homogeneous catalyzed process, which is widely used within chemical industry. Usually applied with simple alkenes like Propene and Butene aldehydes obtained from alkenes >C6 are relevant intermediates in production of plasticizers, surfactants and polymers. Today the active catalyst species is often based on valuable Rhodium complexes in aqueous solution. This implies the problem of limited water solubility of the reactands, which is acceptable for short chain lengths, but states a problem in case of higher alkenes. Along with that efficient separation and recycling of the catalyst becomes more complicated. There are different approaches tackling this problem, e.g., by using of salt formation in the BASF process or downstream distillation within the Shell process T2 - 11. Kolloquium Arbeitskreis Prozessanalytik CY - Wien, Austria DA - 30.11.2015 KW - Prozessanalytik KW - Process analytical technology KW - Emuslions KW - Hydroformylation KW - Online NMR spectroscopy KW - Reaction monitoring PY - 2015 SP - 51 EP - 51 PB - Bundesanstalt für Materialforschung und -prüfung (BAM) CY - Berlin AN - OPUS4-38845 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Kern, Simon A1 - Meyer, Klas A1 - Paul, Andrea A1 - Maiwald, Michael T1 - Ugly Spectra and Lousy interfaces – Challenges for Compact NMR Spectroscopy in Process Control N2 - With the introduction of advanced process analytical technology, the closeness of key process variables to their limits can be directly controlled and the product can be classified or even released in real time. Compact NMR instruments can make NMR spectroscopy accessible in industrial and harsh environments for process control. T2 - ProcessNet-Jahrestagung und 32. DECHEMA-Jahrestagung der Biotechnologen 2016 CY - Aachen, Germany DA - 12.09.2016 KW - Online NMR Spectroscopy KW - Smart Sensors KW - Industrie 4.0 KW - Reaction Monitoring PY - 2016 UR - http://onlinelibrary.wiley.com/doi/10.1002/cite.201650243/full DO - https://doi.org/10.1002/cite.201650243 SN - 1522-2640 VL - 88 SP - 1304 EP - 1317 PB - Wiley-VCH Verlag GmbH & Co. KGaA CY - Weinheim AN - OPUS4-37317 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Meyer, Klas A1 - Ruiken, J.-P. A1 - Illner, M. A1 - Paul, Andrea A1 - Müller, D. A1 - Esche, E. A1 - Repke, J.-U. A1 - Maiwald, Michael T1 - Prozessanalytik für die moderne Verfahrenstechnik – Online-NMR- und -Raman-Spektroskopie im mizellaren Stoffsystem N2 - Homogen katalysierte Reaktionen sind wichtige Werkzeuge der chemischen Industrie. Milde Reaktionsbedingungen und hohe Selektivitäten führen zu einer energie- und ressourcenschonenden Produktion. Ein bedeutender Prozessschritt ist die Hydroformylierung. Hier kommen Kobalt- und Rhodiumkomplexe mit mehrzähnigen Liganden zum Einsatz, die zumeist in wässriger Lösung vorliegen. Die Anwendbarkeit beschränkt sich demnach auf kurzkettige Edukte mit hinreichender Wasserlöslichkeit. T2 - ProcessNet-Jahrestagung und 32. DECHEMA-Jahrestagung der Biotechnologen 2016 CY - Aachen, Germany DA - 12.09.2016 KW - Hydroformylierung KW - Prozessanalytik KW - Prozess-Spektroskopie KW - NMR-Spektroskopie KW - Raman-Spektroskopie KW - Mizellen PY - 2016 UR - http://onlinelibrary.wiley.com/doi/10.1002/cite.201650219/epdf DO - https://doi.org/10.1002/cite.201650219 SN - 1522-2640 VL - 88 SP - 1304 EP - 1317 PB - Wiley-VCH Verlag GmbH & Co. KGaA CY - Weinheim AN - OPUS4-37316 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Paul, Andrea A1 - Breitfeld, S. A1 - Sauer, Andreas A1 - Becker, Roland A1 - Kalbe, Ute A1 - Bremser, Wolfram A1 - Braun, Ulrike T1 - A Raman spectroscopic method for the monitoring of microplastics in soil N2 - Due to the increasing presence of microplastic particles (MP) in the Environment and the unknown risks arising from them, there is an urgent need for analytical methods that allow for an efficient identification and quantification of microplastics (MP), i.e. particles < 5 mm, in environmental samples. So far, mostly timeconsuming (micro) infrared or micro-Raman spectroscopic methods are applied. Here an faster alternative Approach is presented based on a Raman processspectrometer with fiber-optical probes in combination with multivariate data analysis. T2 - 12. Kolloquium Prozessanalytik CY - Berlin, Germany DA - 28.11.2016 KW - Raman spectroscopy KW - Microplastics KW - Soil KW - Chemometrics KW - PLS-DA PY - 2016 SP - P10, 59 EP - 60 AN - OPUS4-38392 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Nadejde, C. A1 - Neamtu, Mariana A1 - Hodoroaba, Vasile-Dan A1 - Schneider, Rudolf A1 - Paul, Andrea A1 - Ababei, G. A1 - Panne, Ulrich T1 - Green Fenton-like catalysts for the removal of water pollutants N2 - Two types of surface modified magnetite (Fe3O4) nanoparticles, coated with either tannic acid (TA) or dissolved natural organic matter (NOM), were evaluated as magnetic heterogeneous catalysts. Simple and efficient procedures for the synthesis of the magnetic catalysts were employed, their properties being fully assessed by various characterization techniques. The catalytic activity in heterogeneous oxidation of aqueous solutions containing Bisphenol A (BPA) over the catalysts was comparatively studied. The optimum experimental parameters were: 1g/L of catalysts, 10 mM H2O2, under UV irradiation. The highest mineralization rates were observed for Fe3O4-TA catalyst. More than 80% of BPA were removed after 30 minutes of reaction time under the specified experimental conditions. The results showed that the obtained catalysts are suitable candidates for the removal of pollutants in wastewaters by means of heterogeneous reaction T2 - TechConnect World Innovation Conference Nanotech 2015 CY - Washington, DC, Maryland, USA DA - 14.06.2015 KW - Nanocatalysts KW - Characterization KW - Fenton oxidation KW - Wastewater KW - Bisphenol A degradation PY - 2015 SN - 978-1- 4987-4733-2 SN - 978-1-4987-4728-8 VL - 2 SP - 87 EP - 90 PB - CRC Press, Taylor&Francis Group AN - OPUS4-40074 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -