TY - JOUR A1 - Schneider, Rudolf A1 - Fernandez, L. A1 - Borzecka, W. A1 - Lin, Z. A1 - Huvaere, K. A1 - Esteves, V. I. A1 - Cunha, A. A1 - Tome, J. P. C. T1 - Nanomagnet-photosensitizer hybrid materials for the degradation of 17 beta-estradiol in batch and flow modes N2 - The preparation of porphyrins and phthalocyanines covalently attached onto nanostructured magnetic supports consisting of magnetite nanoparticles coated with an amorphous silica shell is reported. The easy recovery of these heterogeneous photocatalysts, just by applying an external magnetic field, allows their reuse in multiple treatment cycles. The photocatalytic activity of the non-immobilized photosensitizers and the obtained hybrid materials was evaluated in the degradation of 17 beta-estradiol, as a model organic pollutant present in water, using batch and flow mode treatment systems, assisted by visible light radiation (4 mW cm(-2)). The flow mode system potentiated the photocatalytic capacity of these novel hybrid materials. In order to improve the process, further studies based on different photocatalyst concentration and pH conditions were performed. Reuse capacity of these materials was investigated upon three photocatalytic cycles. KW - Photodegradation KW - 17 beta-Estradiol KW - Porphyrin PY - 2017 DO - https://doi.org/10.1016/j.dyepig.2017.04.010 SN - 0143-7208 VL - 142 SP - 535 EP - 543 PB - Elsevier Ltd. AN - OPUS4-43308 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schneider, Rudolf A1 - Almeida, Ângela A1 - Calisto, V. A1 - Esteves, V. I. A1 - Soares, A. M. V. M. A1 - Figueira, E. A1 - Freitas, R. T1 - Ecotoxicity of the antihistaminic drug cetirizine to Ruditapes philippinarum clams N2 - Cetirizine (CTZ) is an antihistaminic drug present in the aquatic environment, with limited information on its toxicity to organisms inhabiting this system. This study intended to evaluate the effects of CTZ on oxidative stress and energy metabolism biomarkers in the edible clam Ruditapes philippinarum after a 28 days exposure to environmentally relevant CTZ concentrations (0.0, 0.3, 3.0, 6.0 and 12.0 mu g/L). The results obtained showed that CTZ was accumulated by clams reaching maximum concentrations (up to similar to 22 ng/g FW) at the highest CTZ exposure concentrations (6.0 and 12.0 mu g/L). The bioconcentration factor (average maximum values of similar to 5) decreased at 12.0 mu g/L reflecting a reduction in clams uptake or increase of excretion capacity at this condition. The present study revealed that, in general, clams decreased the metabolic potential after exposure to CTZ (decrease in electron transport system activity), a response that led to the maintenance of glycogen content in organisms exposed to CTZ in comparison to control values. Our findings also showed that, CTZ did not exert significant levels of oxidative injury to clams. However, comparing the control with the highest exposure concentrations (6.0 and 12.0 mu g/L) a significant increase of the antioxidant enzyme superoxide activity (similar to 53 and similar to 44%) was observed in clams exposed to CTZ. Moreover, a tendency to increase lipid peroxidation (similar to 14 and similar to 9%) and carbonyl groups on proteins (similar to 11 and similar to 3%) was observed in clams exposed to CTZ (6.0 and 12.0 mu g/L) compared to control condition. Overall the present study suggests that toxic impacts may be induced in R. philippinarum if exposed for longer periods or higher CTZ concentrations. KW - Antihistamines KW - Clams KW - Biomarkers PY - 2017 DO - https://doi.org/10.1016/j.scitotenv.2017.05.149 SN - 0048-9697 VL - 601 SP - 793 EP - 801 PB - Elsevier B.V. AN - OPUS4-43311 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carvalho, Ana Margarida A1 - Véliz Montes, Cinthya A1 - Schneider, Rudolf A1 - Madder, A. T1 - An anti-caffeine antibody−oligonucleotide conjugate for DNA-directed immobilization in environmental immunoarrays N2 - The development of fast and cheap highthroughput platforms for the detection of environmental contaminants is of particular importance to understand the human-related impact on the environment. The application of DNA-directed immobilization (DDI) of IgG molecules is currently limited to the clinical diagnostics scenario, possibly because of the high costs of production of such addressable platforms. We here describe the efficient and specific hybridization of an antibody−oligonucleotide conjugate to a short 12-mer capture probe. The specific antibody used is a monoclonal antibody against caffeine, a stimulant and important anthropogenic marker. With this work, we hope to contribute to broadening the application potential of DDI to environmental markers in order to develop cheaper and more stable high-throughput screening platforms for standard Routine analysis of pollutants in a variety of complex matrices. KW - Oligo KW - Antikörperkonjugate KW - Antikörper KW - Biokonjugation KW - Koffein KW - Array PY - 2018 DO - https://doi.org/10.1021/acs.langmuir.8b01347 SN - 0743-7463 VL - 34 IS - 49 SP - 14834 EP - 14841 PB - American Chemical Society CY - Hoboken, New Jersey, USA AN - OPUS4-46982 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Fernández, L. A1 - Lin, Z. A1 - Schneider, Rudolf A1 - Esteves, V. I. A1 - Cunha, Â. A1 - Tomé, J. P. C. T1 - Antimicrobial Photodynamic Activity of Cationic Nanoparticles Decorated with Glycosylated Photosensitizers for Water Disinfection N2 - The antimicrobial photodynamic approach has been demonstrated as an efficient and sustainable process for the eradication of microbial pathogens. In this work, silica-coated Magnetite nanoparticles (NPs) were used as carriers of glycosylated porphyrins and phthalocyanines. Their subsequent cationization resulted in the production of stable antimicrobial photosensitizing materials, effective against E. coli. Suspensions of the photocatalysts in water present bimodal size distributions formed by big clusters and small NPs with hydrodynamic diameters between 8 and 38 nm. The presence of small NPs in the suspensions is related to an effective photodynamic inactivation (PDI) of E. coli cells. Glycosylation of the PS showed a positive effect on the PDI performance, which could be related to a higher accumulation of the photocatalyst over the bacterial cell membrane. In addition, these biocidal agents proved to be photostable and their photoactive performance decreased only between 23% and 28% upon 5 PDI cycles, mostly because of the loss of material between cycles, which makes them promising materials for water disinfection purposes. KW - Photodynamische Inaktivierung KW - E. coli KW - Photokatalyse KW - Bakterien KW - Nanopartikel KW - Photosensibilisator KW - Porphyrin KW - Phthalocyanin PY - 2018 DO - https://doi.org/10.1002/cptc.201700169 SN - 2367-0932 VL - 2 IS - 7 SP - 596 EP - 605 PB - Wiley VHC CY - Weinheim AN - OPUS4-45684 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Ramos, Inês I. A1 - Carl, Peter A1 - Schneider, Rudolf A1 - Segundo, Marcela A. T1 - Development of automated immunosensing methods for clinical and environmental Analysis using lab-on-valve platforms N2 - The lab-on-valve (LOV) is a mesofluidic platform that has been recently exploited for the automation and miniaturization of bioanalytical assays, resorting namely to molecular recognition schemes based on immunosensing. Due to its high versatility for reagent accommodation, it is possible to establish immunoassays under several formats (eg. direct competitive ELISA, sandwich ELISA or even label-free immunoaffinity chromatography). For instance, the LOV has been used as a manifold for UV-vis micro-Bead Injection Spectroscopy (μ-BIS), a technique that involves the quantification of the target analyte by direct measurement on the surface of a solid phase capable of retaining the target analyte by molecular recognition. The μ-BIS-LOV strategy affords several analytical advantages, namely short time-toresult intervals (3 to 15 min), low sample volume (1-20 μL), automated solution handling and washing steps, downscaling of reagents’ consumption, low-cost analysis and little generation of waste. Additionally, the solid support is renewed before each determination, minimizing surface fouling, cross-contamination issues and functional group deactivation. No sample clean-up steps are required because interferences are separated from the target analyte upon quantification mediated by a molecular recognition element attached to the micro-bead column. The portability of the LOV device makes it compatible with point-of-care testing. To our knowledge, this technique has been mainly employed for the evaluation and optimization of bioaffinity processes, but its potential for clinical and environmental analysis remains underexploited. Hence, in this communication, different immunosensing strategies using the LOV platform will be addressed, namely the determination of autoimmune IgG in human serum, and the assessment of drug (carbamazepine) levels in wastewater samples. T2 - EBS 2017 CY - Potsdam, Germany DA - 20.03.2017 KW - Lab-on-valve KW - Automation KW - Immunoassay PY - 2017 AN - OPUS4-39521 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Dippong, Martin A1 - Carl, Peter A1 - Lenz, C. A1 - Schenk, J. A. A1 - Hoffmann, Katrin A1 - Schwaar, Timm A1 - Schneider, Rudolf A1 - Kuhne, Maren T1 - Hapten-specific single-cell selection of hybridoma clones by fluorescence-activated cell sorting for the generation of monoclonal antibodies N2 - The conventional hybridoma screening and subcloning process is generally considered to be one of the most critical steps in hapten-specific antibody production. It is time-consuming, monoclonality is not guaranteed, and the number of clones that can be screened is limited. Our approach employs a novel hapten-specific labeling technique of hybridoma cells. This allows for fluorescence-activated cell sorting (FACS) and single-cell deposition and thereby eliminates the above-mentioned problems. A two-step staining approach is used to detect antigen specificity and antibody expression: in order to detect antigen specificity, hybridoma cells are incubated with a hapten−horseradish peroxidase conjugate (hapten−HRP), which is subsequently incubated with a fluorophore-labeled polyclonal anti-peroxidase antibody (anti-HRP−Alexa Fluor 488). To characterize the expression of membrane-bound immunoglobulin G (IgG), a fluorophore-labeled anti-mouse IgG antibody (anti-IgG−Alexa Fluor 647) is used. Hundreds of labeled hybridoma cells producing monoclonal antibodies (mAbs) specific for a hapten were rapidly isolated and deposited from a fusion mixture as single-cell clones via FACS. Enzyme-linked immunosorbent assay (ELISA) measurements of the supernatants of the sorted hybridoma clones revealed that all hapten-specific hybridoma clones secrete antibodies against the target. There are significant improvements using this high-throughput technique for the generation of mAbs including increased yield of antibody-producing hybridoma clones, ensured monoclonality of sorted cells, and reduced development times. KW - Monoclonal antibodies KW - FACS KW - Hybridoma cells PY - 2017 DO - https://doi.org/10.1021/acs.analchem.6b04569 SN - 0003-2700 SN - 1520-6882 VL - 89 IS - 7 SP - 4007 EP - 4012 PB - ACS Publications AN - OPUS4-40320 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Véliz Montes, Cinthya A1 - Memczak, H. A1 - Gyssels, E. A1 - Torres, T. A1 - Madder, A. A1 - Schneider, Rudolf T1 - Photoinduced cross-linking of short Furan-modified DNA on surfaces N2 - We report for the first time the formation of sitespecific interstrand cross-linked (ICL) surface-immobilized furanmodified DNA duplexes via singlet oxygen. 1O2, necessary for effecting furan-mediated ICL formation, was produced in situ using methylene blue or a zinc phthalocyanine derivative (TT1) as a photosensitizer. Via surface plasmon resonance spectroscopy, we show that surface ICL was achieved, and a robust link formed that enhances the stability of the 12-mer duplex even after surface regeneration. The described method represents a novel platform technology based on surfaces with addressable and stable DNA duplexes requiring only short oligonucleotides. KW - DNA interstrand cross-link (ICL) KW - Furanmodified DNA duplexes KW - Surface plasmon resonance spectroscopy PY - 2017 DO - https://doi.org/10.1021/acs.langmuir.6b03855 SN - 0743-7463 SN - 1520-5827 VL - 33 IS - 5 SP - 1197 EP - 1201 PB - ACS Publications AN - OPUS4-39155 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schlepütz, M. A1 - Buthe, A. A1 - Brenneis, Rudolf A1 - Ansorge-Schumacher, M. B. T1 - Lipase-catalysed synthesis of ester oils from biodiesel by-products N2 - Ester oils obtained from natural long-chain fatty acids and alcohols are versatile substitutes for many petroleum-based products. Their efficient synthesis with the solvent-free esterification of free fatty acids (FFA) from by-products of biodiesel fabrication and 2-ethyl-1-hexanol with immobilised lipase from Thermomyces lanuginosa was investigated. The immobilisation of the biocatalyst in static emulsion yielded a specific esterification activity that was higher by a factor of 4.9-9.4 than the activity of the native enzyme. Favourable properties of the silicone-based immobilisation matrix in terms of stability and immobilisation yield were observed. In biodiesel by-products, the immobilised lipase catalysed the esterification of FFA as well as the transesterification of residual fatty acid methyl esters (FAME) to the desired ester oils. A conversion of 90% FFA and 35% FAME gave a total yield of 60%. The inactivation coefficients during repeated use in a stirred-tank reactor with intermittent pressure reduction were exceptionally low. KW - Ester oil KW - Biodiesel KW - Lipase KW - Esterification KW - Static emulsion PY - 2008 DO - https://doi.org/10.1080/10242420701668904 SN - 1024-2422 SN - 1029-2446 VL - 26 IS - 3 SP - 220 EP - 227 PB - Taylor & Francis CY - London AN - OPUS4-17356 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Filipe, O.M.S. A1 - Vidal, M.M. A1 - Scherer, H.W. A1 - Schneider, Rudolf A1 - Duarte, A. A1 - Esteves, V.I. A1 - Santos, E.B.H. T1 - Effect of long term organic amendments on adsorption-desorption of thiram onto a luvisol soil derived from loess KW - Thiram KW - Adsorption-desorption KW - Soil KW - Organic amendments PY - 2010 DO - https://doi.org/10.1016/j.chemosphere.2010.04.003 SN - 0045-6535 SN - 0366-7111 VL - 80 IS - 3 SP - 293 EP - 300 PB - Elsevier Science CY - Kidlington, Oxford AN - OPUS4-23196 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lima, D. A1 - Santos, S A1 - Scherer, H. A1 - Schneider, Rudolf A1 - Duarte, A. A1 - Santos, E. A1 - Esteves, V. T1 - Effects of organic and inorganic amendments on soil organic matter properties N2 - The aim of this work was to investigate the effects of long-term application of different organic fertilizers (sewage sludge, farmyard manure, compost) as compared to mineral fertilizer on the structure of the soil organic matter. Capillary electrophoresis was employed for the quantification of monosaccharides and phenolic compounds, whereas NMR and FT-IR were used for the overall characterization of the soils organic matter. Application of farmyard manure results in a higher content of organic matter derived from angiosperms, suggested by the higher levels of syringic and vanillic phenols. Spectroscopic studies show an increase of lignin and lignin-like products in the organic matter of the soil, which may be derived from the cereal straw supplied with farmyard manure. According to spectroscopic analysis, 13C CPMAS-NMR and FT-IR spectra, higher contents of methylene groups (– CH2) from proteins and protein-like compounds, as well as higher levels of carbohydrates, were found in the soil supplied with compost. The monosaccharide (rhamnose, xylose, glucose, mannose, arabinose, fucose and galactose) content was not significantly influenced by the different organic fertilizers, suggesting that the type of amendment used does not affect any of these six studied monomers. Comparing the three organic amendments the most significant differences were observed after long-term application of farmyard manure, with an increase in lignin and lignin-like products in the soil organic matter, and compost, which appears to contribute to an increase of protein and protein-like, as well as carbohydrates content on soil organic matter. The knowledge of such changes can be essential to understand the sorption and bioavailability of pollutants, as well as establish/unestablish ways to recycling organic residues as organic fertilizers. KW - Soil amendment KW - Organic matter charcterization KW - Phenols KW - Monosaccharide KW - CZE KW - FT-IR KW - 13C-NMR PY - 2009 DO - https://doi.org/10.1016/j.geoderma.2009.01.009 SN - 0016-7061 SN - 1872-6259 VL - 150 IS - 1-2 SP - 38 EP - 45 PB - Elsevier CY - Amsterdam AN - OPUS4-19333 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Martínez, N.A. A1 - Schneider, Rudolf A1 - Messina, G.A. A1 - Raba, J. T1 - Modified paramagnetic beads in a microfluidic system for the determination of ethinylestradiol (EE2) in river water samples N2 - In this work, we have developed and characterized a novel microfluidic immunoassay methodology for rapid and sensitive quantification of ethinylestradiol (EE2) in river water samples. The detection of EE2 was carried out using a competitive direct immunoassay method based on the use of anti-EE2 polyclonal antibodies immobilized on magnetic microspheres 3-aminopropyl-modified manipulated for an external removable magnet. The EE2 present in the water sample was allowed to compete with EE2-horseradish peroxidase (HPR) conjugated for the immobilized anti-EE2 antibody. The HPR, in the presence of hydrogen peroxide (H2O2) catalyzes the oxidation of catechol (Q) whose back electrochemical reduction was detected on gold electrode at 0.0 V. The response current obtained from the product of enzymatic reaction is inversely proportional to the amount of EE2 in the water sample. The electrochemical detection can be done within 1 min and total assay time was 30 min. The calculated detection limits for electrochemical detection and the ELISA procedure are 0.09 and 0.32 ng L-1 respectively and the intra- and inter-assay coefficients of variation were below 5.8%. Our electrochemical immunosensor showed higher sensitivity and lower time consumed than the standard spectrophotometric detection ELISA method, which shows the potential for assessment of EE2 in river water samples. KW - Enzyme immunoassays KW - Ethinylestradiol KW - Paramagnetic beads KW - Horseradish peroxidase KW - Microfluidic KW - Flow injection analysis PY - 2010 DO - https://doi.org/10.1016/j.bios.2009.10.031 SN - 0956-5663 SN - 1873-4235 VL - 25 IS - 6 SP - 1376 EP - 1381 PB - Elsevier CY - Barking, Essex, UK AN - OPUS4-22188 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Hesselbach, J. A1 - Herrmann, C. A1 - Bock, R. A1 - Dettmer, T. A1 - Kley, Gerd A1 - Köcher, Peter A1 - Brenneis, Rudolf A1 - Meyer-Pittroff, R. A1 - Falk, O. A1 - Hansen, A. T1 - Kühlschmierstoffe aus technischen tierischen Fetten und Altspeisefetten - Herstellung, Technologie und Ökobilanzierung KW - Enzymatische Alkoholyse KW - Tierfett KW - Altspeisefett KW - Kühlschmierstoff KW - Umesterung KW - Produktökobilanz KW - LCA PY - 2003 SN - 1435-5272 VL - 9 IS - Sonderheft `Biokatalyse´ SP - 24 EP - 27 PB - BIOCOM CY - Berlin AN - OPUS4-2684 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rudolf, A. A1 - Kaiser, W.-D. A1 - Dörfel, Ilona A1 - Engelhardt, Monika A1 - Österle, Werner T1 - Zum Zusammenhang von Filiformkorrosion und Gefüge von Aluminiumlegierungen, Teil I PY - 2002 SN - 0002-6689 N1 - Sprachen: Deutsch/Englisch - Languages: German/English VL - 78 IS - 7/8 SP - 596 EP - 601 PB - Giesel CY - Isernhagen AN - OPUS4-2074 LA - mul AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Rudolf, A. A1 - Kaiser, W.-D. A1 - Dörfel, Ilona A1 - Engelhardt, Monika A1 - Österle, Werner T1 - Zum Zusammenhang von Filiformkorrosion und Gefüge von Aluminiumlegierungen, Teil II PY - 2002 SN - 0002-6689 N1 - Sprachen: Deutsch/Englisch - Languages: German/English VL - 78 IS - 11 SP - 994 EP - 1000 PB - Giesel CY - Isernhagen AN - OPUS4-2075 LA - mul AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Brenneis, Rudolf A1 - Wichmann, H. A1 - Sprenger, R. A1 - Eickhoff, A. A1 - Bock, R. A1 - Dettmer, T. A1 - Baeck, Burkhard A1 - Reger, Christian A1 - Bahadir, M. T1 - Nativ-basierte Grundöle für die Produktion von Kühlschmierstoffen - Stand der Entwicklung und Defizite N2 - Hintergrund und Ziel. Kühlschmierstoffe auf der Basis von Fettsäureestern bieten technologische Vorteile gegenüber mineralölbasierten Produkten. Außerdem sind sie umweltgerechter und leisten einen Beitrag zum nachhaltigen Wirtschaften. Dennoch werden sie in der Praxis kaum eingesetzt, da sie bisher aufgrund von Rohstoffpreisen und Synthesekosten teurer sind, als konventionelle Konkurrenzprodukte. Alternativen hinsichtlich Rohstoffen und Synthesewegen werden betrachtet und die Eigenschaftsbilder resultierender Esterprodukte miteinander verglichen. Methoden. In die Untersuchungen wurden drei auf enzymatischkatalytischem Weg hergestellte Fettsäure-2-Ethylhexylester auf der Basis von Erdnussfett, Rindertalg und Altspeisefett sowie vier konventionell synthetisierte Ester aus Tier- bzw. Pflanzenfetten und 2-Ethyl-1-Hexanol einbezogen. Bestimmt wurden physikalische Eigenschaftswerte, Fettsäurespektren, Gehalte an freien Fettsäuren sowie Oxidations- und Hydrolysestabilitäten. Ferner wurden Thermolyseexperimente durchgeführt. Ergebnisse. Die physikalischen Eigenschaften der sieben Ester, d.h. Dichte, Viskosität, Pourpoint und Flammpunkt, waren vergleichbar und ließen die Anwendbarkeit der Produkte als Basisöle für Kühlschmierstoffe erwarten. Hydrolysebeständigkeiten waren hoch und thermische Belastungen der Ester gaben keine Hinweise auf besondere Schadstoffbildungspotentiale. Defizite wiesen insbesondere die enzymatisch hergestellten Ester hinsichtlich Oxidationsstabilitäten und den Gehalten an freien Fettsäuren auf. Ausblick. Für die Praxis wird es notwendig sein, Mindestqualitäten für Rohstoffe und resultierende Esteröle zu definieren, die als Grundöle im Kühlschmierstoffbereich eingesetzt werden sollen. Außerdem müssen Verfahren ausgearbeitet werden, die es ermöglichen, zu qualitativ hochwertigen Esterprodukten zu gelangen, ohne den Preisvorteil von Rohstoffen wie Altspeise- und Tierfetten durch hohe Produktions- und Veredelungskosten zu verlieren. Ein Beitrag hierzu ist sicherlich die Weiterentwicklung der wenig energieaufwändigen enzymatischen Alkoholyse zur Esterproduktion. KW - Altspeisefett KW - Enzymatische Alkoholyse KW - Fettsäureethylhexylester KW - Kühlschmierstoffe KW - Cooling lubricants KW - Enzymatic alcoholysis KW - Fatty acid ethylhexylester KW - Waste edible fat PY - 2006 DO - https://doi.org/10.1065/uwsf2006.03.115 SN - 0934-3504 SN - 1865-5084 VL - 18 IS - 2 SP - 95 EP - 101 PB - Springer CY - Heidelberg AN - OPUS4-12439 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Abdelshafi, Nahla A. A1 - Bell, Jérémy A1 - Rurack, Knut A1 - Schneider, Rudolf T1 - Microfluidic electrochemical immunosensor for the trace analysis of cocaine in water and body fluids N2 - Quick but accurate testing and on‐the‐spot monitoring of cocaine in oral fluids and urine continues to be an important toxicological issue. In terms of drug testing, a number of devices have been introduced into the market in recent decades, notably for workplace inspection or roadside testing. However, these systems do not always fulfill the requirements in terms of reliability, especially when low cut‐off levels are required. With respect to surface water, the presence of anthropogenic small organic molecules such as prescription and over‐the‐counter pharmaceuticals as well as illicit drugs like cannabinoids, heroin, or cocaine, has become a challenge for scientists to develop new analytical tools for screening and on‐site analysis because many of them serve as markers for anthropogenic input and consumer behavior. Here, a modular approach for the detection of cocaine is presented, integrating an electrochemical enzyme‐linked immunosorbent assay (ELISA) performed on antibody‐grafted magnetic beads in a hybrid microfluidic sensor utilizing flexible tubing, static chip and screen‐printed electrode (SPE) elements for incubation, recognition, and cyclic voltammetry measurements. A linear response of the sensor vs. the logarithm of cocaine concentration was obtained with a limit of detection of 0.15 ng/L. Within an overall assay time of 25 minutes, concentrations down to 1 ng/L could be reliably determined in water, oral fluids, and urine, the system possessing a dynamic working range up to 1 mg/L. KW - Cocaine PY - 2018 DO - https://doi.org/10.1002/dta.2515 VL - 11 SP - 492 EP - 500 PB - Wiley CY - Weinheim AN - OPUS4-48319 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Abdelshafi, Nahla A. A1 - Panne, Ulrich A1 - Schneider, Rudolf T1 - Screening for cocaine on Euro banknotes by a highly sensitive enzyme immunoassay N2 - This study focused on quantitative detection of cocaine on Euro banknotes in Germany. A sensitive direct competitive immunoassay was developed and optimized with a limit of detection (LOD) of 5.6 ng/L. Exhaustive cocaine extraction by solvent was tested using different methanol concentrations and buffered solutions. Crossreactivity studies were performed to determine the degree of interference of cocaine metabolites with the immunoassay. Sixty-five Euro banknotes obtained from different districts in Berlin were evaluated. A 100% contamination frequency with cocaine was detected. A comparison between the amount of cocaine extracted by cotton swabbing of one square centimeter of the banknote showed a good correlation for lower contamination levels. This assay showed high sensitivity of detecting pg of cocaine per 1 cm2 of one banknote by swabbing 1 cm2: 0, 14, and 21 pg/cm2. Moreover, three notes of different denominations revealed high cocaine concentration; 1.1 mg/note, and twice 55 μg/note. KW - Cocaine KW - Euro banknotes KW - Drugs on bills KW - Enzyme-Linked Immunosorbent Assay KW - ELISA PY - 2017 DO - https://doi.org/10.1016/j.talanta.2017.01.004 SN - 0039-9140 SN - 1873-3573 VL - 165 SP - 619 EP - 624 PB - Elsevier AN - OPUS4-39150 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Braeutigam, P. A1 - Franke, M. A1 - Schneider, Rudolf A1 - Lehmann, Andreas A1 - Stolle, A. A1 - Ondruschka, B. T1 - Degradation of carbamazepine in environmentally relevant concentrations in water by hydrodynamic-acoustic-cavitation (HAC) N2 - The antiepileptic drug carbamazepine is one of the most abundant pharmaceuticals in the German aquatic environment. The effect of low carbamazepine concentrations (1–50 µg L-1) is discussed controversially, but ecotoxicological studies revealed reproduction toxicity, decreased enzymatic activity and bioaccumulation in different test organisms. Therefore, as a preventive step, an efficient and cost-effective technique for wastewater treatment plants is needed to stop the entry of pharmaceuticals into the aquatic environment. Cavitation, the formation, growth, and subsequent collapse of gas- or vapor-filled bubbles in fluids, was applied to solve this problem. The technique of Hydrodynamic-Acoustic-Cavitation was used showing high synergistic effect. Under optimized conditions carbamazepine (5 µg L-1) was transformed by pseudo-first order kinetics to an extent of >96% within 15 min (27% by hydrodynamic cavitation, 33% by acoustic cavitation). A synergistic effect of 63% based on the sum of the single methods was calculated. Carbamazepine concentrations were monitored by a sensitive and selective immunoassay and after 60 min no known metabolites were detectable by LC-MS/MS. KW - Carbamazepine KW - Degradation KW - Hydrodynamic cavitation KW - Acoustic cavitation KW - ELISA PY - 2012 DO - https://doi.org/10.1016/j.watres.2012.02.013 SN - 0043-1354 VL - 46 IS - 7 SP - 2469 EP - 2477 PB - Elsevier CY - Amsterdam AN - OPUS4-25735 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Abdelshafi, Nahla A. A1 - Bell, Jérémy A1 - Rurack, Knut A1 - Schneider, Rudolf T1 - Microfluidic electrochemical immunosensor for the trace analysis of cocaine in water and body fluids N2 - Quick but accurate testing and on‐the‐spot monitoring of cocaine in oral fluids and urine continues to be an important toxicological issue. In terms of drug testing, a number of devices have been introduced into the market in recent decades, notably for workplace inspection or roadside testing. However, these systems do not always fulfill the requirements in terms of reliability, especially when low cut‐off levels are required. With respect to surface water, the presence of anthropogenic small organic molecules such as prescription and over‐the‐counter pharmaceuticals as well as illicit drugs like cannabinoids, heroin, or cocaine, has become a challenge for scientists to develop new analytical tools for screening and on‐site analysis because many of them serve as markers for anthropogenic input and consumer behavior. Here, a modular approach for the detection of cocaine is presented, integrating an electrochemical enzyme‐linked immunosorbent assay (ELISA) performed on antibody‐grafted magnetic beads in a hybrid microfluidic sensor utilizing flexible tubing, static chip and screen‐printed electrode (SPE) elements for incubation, recognition, and cyclic voltammetry measurements. A linear response of the sensor vs. the logarithm of cocaine concentration was obtained with a limit of detection of 0.15 ng/L. Within an overall assay time of 25 minutes, concentrations down to 1 ng/L could be reliably determined in water, oral fluids, and urine, the system possessing a dynamic working range up to 1 mg/L. KW - ELISA KW - Kokain KW - Lab-on-chip KW - Speichel KW - Urin KW - Drogenanalytik KW - Schnelltest KW - Biosensor PY - 2018 DO - https://doi.org/10.1002/dta.2515 SN - 1942-7611 VL - 11 IS - 3 SP - 492 EP - 500 PB - Wiley-VCH CY - Hoboken, New Jersey, USA AN - OPUS4-46888 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Noack, M. A1 - Dittmar, A. A1 - Stöhr, M. A1 - Georgi, G. A1 - Adam, Christian A1 - Brenneis, Rudolf A1 - Kley, Gerd A1 - Lehmann, Annekatrin A1 - Handte, J. A1 - Meichle, K. A1 - Schwake, M. T1 - Thermische Regenerierung von Zeolithpulver Typ X aus der VOC-Luftreinigung N2 - Für die Entfernung von VOC (volatile organic compounds) aus der Luft von Fertigungsstätten werden vielfach mikroporöse Adsorbentien eingesetzt. Die gereinigte Luft wird rezyklisiert. Für die mit VOC beladenen Adsorbentien wird ein Regenerierungsweg für den mehrfachen Gebrauch gesucht. Bei der Regenerierung sollen die VOC möglichst vollständig desorbiert werden und mit einer geringen Gasmenge in einer katalytischen Verbrennung zu CO2 und H2O umgewandelt werden. Die Wirtschaftlichkeit der Luftreinigung wird wesentlich bestimmt durch die Sorptionskapazität des Adsorbens, die erforderliche Energie für die thermische Regenerierung und die Menge des Spülgases bei der Regenerierung. In dieser Arbeit wird der Einsatz von Typ X-Zeolithpulver in der Luftreinigung einer Lackiererei beschrieben und dessen Regenerierung im Labor mittels DTA/TG und Isothermenmessung der Schlüsselkomponenten untersucht. Ferner wurde die Regenerierung des beladenen Zeoliths in einem Labor-Drehrohrofen unter Variation der Betriebsparameter untersucht und anschließend mit ausgewählten Parametern in einem kleintechnischen Drehrohrofen durchgeführt. Die Verfahrensvarianten werden diskutiert. KW - Adsorption KW - Verfahrensentwicklung KW - VOC KW - Zeolithe PY - 2007 SN - 0009-286X SN - 1522-2640 VL - 79 IS - 6 SP - 883 EP - 889 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-14975 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Riedel, Soraya A1 - Hülagü, Deniz A1 - Bennet, Francesca A1 - Carl, Peter A1 - Flemig, Sabine A1 - Schmid, Thomas A1 - Schenk, J. A. A1 - Hodoroaba, Vasile-Dan A1 - Schneider, Rudolf T1 - Electrochemical Immunomagnetic Ochratoxin A Sensing: Steps Forward in the Application of 3,3’,5,5’- Tetramethylbenzidine in Amperometric Assays N2 - Electrochemical methods offer great promise in meeting the demand for user-friendly on-site devices for Monitoring important parameters. The food industry often runs own lab procedures, for example, for mycotoxin analysis, but it is a major goal to simplify analysis, linking analytical methods with smart technologies. Enzyme-linked immunosorbent assays, with photometric detection of 3,3’,5,5’-tetramethylbenzidine (TMB),form a good basis for sensitive detection. To provide a straightforward approach for the miniaturization of the detectionstep, we have studied the pitfalls of the electrochemical TMB detection. By cyclic voltammetry it was found that the TMB electrochemistry is strongly dependent on the pH and the electrode material. A stable electrode response to TMB could be achieved at pH 1 on gold electrodes. We created a smartphonebased, electrochemical, immunomagnetic assay for the detection of ochratoxin A in real samples, providing a solid basis forsensing of further analytes. KW - Ochratoxin A KW - Amperometry KW - Cyclic voltammetry KW - Electrochemistry KW - Immunoassay PY - 2021 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-530421 DO - https://doi.org/10.1002/celc.202100446 N1 - Geburtsname von Riedel, Soraya: Höfs, S. - Birth name of Riedel, Soraya: Höfs, S. VL - 8 IS - 13 SP - 2597 EP - 2606 AN - OPUS4-53042 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carl, Peter A1 - Ramos, Inês I. A1 - Segundo, Marcela A. A1 - Schneider, Rudolf T1 - Antibody conjugation to carboxyl-modified microspheres through N-hydroxysuccinimide chemistry for automated immunoassay applications: A general procedure N2 - Immunochemical techniques are the workhorse for sample enrichment and detection of a large variety of analytes. In contrast to classical microtiter plate-based assays, microparticles are a next generation solid support, as they promote automation of immunoassays using flow-based techniques. Antibody immobilization is a crucial step, as these reagentsmare expensive, and inefficient coupling can result in low sensitivities. This paper proposes a general procedure for efficient immobilization of antibodies onto TentaGel particles, via Nhydroxysuccinimide chemistry. The goal was the preparation of solid supports with optimum immunorecognition, while increasing the sustainability of the process. The influence of buffer composition, activation and coupling time, as well as the amount of antibody on the immobilization efficiency was investigated, resorting to fluorophore-labeled proteins and fluorescence imaging. Buffer pH and activation time are the most important parameters for efficient coupling. It is demonstrated, that the hydrolysis of N-hydroxysuccinimide esters occurs at similar rates as in solution, limiting the utilizable time for coupling. Finally, applicability of the generated material for automated affinity extraction is demonstrated on the mesofluidic platform lab-on-valve. KW - Mesofluidics KW - Bead injections KW - ELISA KW - Carbamazepine KW - Biomarkers PY - 2019 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-483919 DO - https://doi.org/10.1371/journal.pone.0218686 SN - 1932-6203 VL - 14 IS - 6 SP - e0218686, 1 EP - 18 PB - Public Library of Science CY - San Francisco, California, USA AN - OPUS4-48391 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Ramos, I. I. A1 - Carl, Peter A1 - Schneider, Rudolf A1 - Segundo, M. A. T1 - Automated lab-on-valve sequential injection ELISA for determination of carbamazepine N2 - The development of an automated miniaturized analytical system that allows for the rapid monitoring of carbamazepine (CBZ) levels in serum and wastewater is proposed. Molecular recognition of CBZ was achieved through its selective interaction with microbeads carrying anti-CBZ antibodies. The proposed method combines the advantages of the micro-bead injection spectroscopy and of the flow-based platform lab-on-valve for implementation of automatic immunosorbent renewal, rendering a new recognition surface for each sample. The sequential (or simultaneous) perfusion of CBZ and the horseradish peroxidase-labelled CBZ through the microbeads is followed by real-time on-column Monitoring of substrate (3,30,5,50-tetramethylbenzidine) oxidation by colorimetry. The evaluation of the initial oxidation rate and also the absorbance value at a fixed time point provided a linear response versus the logarithm of the CBZ concentration. Under the selected assay conditions, a single analysis was completed after only 11 min, with a quantification range between 1.0 and 50 µg L⁻¹. Detection of CBZ levels in undiluted wastewater samples was feasible after a simple filtration step while good recoveries were attained for spiked certified human serum, analyzed without sample clean-up. KW - Automation KW - Bead injection spectroscopy KW - Human serum KW - Microparticles KW - Therapeutic Drug Monitoring KW - Wastewater PY - 2019 DO - https://doi.org/10.1016/j.aca.2019.05.017 SN - 0003-2670 VL - 1076 SP - 91 EP - 99 PB - Elsevier CY - Amsterdam AN - OPUS4-48317 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Singh, Chandan A1 - Riedel, Soraya A1 - Konthur, Zoltán A1 - Hodoroaba, Vasile-Dan A1 - Radnik, Jörg A1 - Schenk, J. A. A1 - Schneider, Rudolf T1 - Functionalized Ti3C2Tx nanosheets based biosensor for point-of-care detection of SARS-CoV‑2 antigen N2 - MXenes are considered a promising class of two-dimensional materials with extraordinary physical and electrochemical properties. Distinguished features like high specific surface area and outstanding electrical conductivity make them suitable for electrochemical biosensing applications. Here, we report the development of a biosensor involving the functionalized MXene−titanium carbide nanosheets (Ti3C2Tx-NS) and monoclonal antibodies against the SARS-CoV-2 nucleocapsid protein (anti-SARS-CoV-2 mAb) to design a point-of-care device for detection of the SARS-CoV-2 nucleocapsid protein (SARS-CoV-2 NP) antigen. Few-layered titanium carbide nanosheets (denoted as FL-Ti3C2Tx-NS) have been synthesized using a single-step etching and delamination method and characterized using optical and electron microscopy techniques revealing the suitability for immunosensing applications. Binding studies revealed the excellent affinity between the biosensor and the SARS-CoV-2 NP. Electrochemical detection of SARS-CoV-2 NP is performed using differential pulse voltammetry and read by a smartphone-based user interface. The proposed FL-Ti3C2Tx-NS based biosensor offers the detection of SARS-CoV-2 NP with a limit of detection of 0.91 nM in a wide detection range in spiked saliva samples. Additionally, there is no cross-reactivity in the presence of potential interferants like SARS-CoV-2 spike glycoprotein and bovine serum albumin. These findings demonstrate the potential of MXenes in developing a rapid and reliable tool for SARS-CoV-2 NP detection. While we report the biosensing of SARS-CoV-2 NP, our system also paves the way for the detection of other SARS-CoV-2 antigens like spike protein or other biomolecules based on antigen−antibody interactions. KW - Antigen testing KW - Few-layered titanium carbide nanosheets KW - SARS-CoV-2 nucleocapsid protein KW - Label-free detection KW - Electrochemical immunosensor PY - 2023 DO - https://doi.org/10.1021/acsaenm.2c00118 SN - 2771-9545 N1 - Geburtsname von Riedel, Soraya: Höfs, S. - Birth name of Riedel, Soraya: Höfs, S. VL - 1 IS - 1 SP - 495 EP - 507 PB - American Chemical Society CY - Washington, DC AN - OPUS4-56931 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Beyer, Sebastian A1 - Schürmann, Robin A1 - Feldmann, Ines A1 - Blocki, A. A1 - Bald, Ilko A1 - Schneider, Rudolf A1 - Emmerling, Franziska T1 - Maintaining Stable Zeolitic Imidazolate Framework (ZIF) Templates during Polyelectrolyte Multilayer Coating N2 - Equipping ZIF particles with a polyelectrolyte membrane provides functional groups at their interface, enabling further conjugations necessary for applications such as targeted drug delivery. Previous approaches to coat ZIF particles with polyelectrolytes led to surface corrosion of the template material. This work overcomes previous limitations by performing a Layer-by-Layer (LbL) polyelectrolyte coating onto ZIF-8 and ZIF-67 particles in nonaqueous environment. Using the 2-methylimidazolium salt of polystyrensulfonic acid instead of the acid itself and polyethyleneimine in methanol led to intact ZIF particles after polyelectrolyte coating. This was verified by electron microscopy. Further, zetapotential and atomic force microscopy measurements confirmed a continuous polyelectrolyte multilayer built up. The here reported adaption to the well-studied (LbL) polyelectrolyte selfassembly process provides a facile method to equip ZIF particles with a nanometer thin polyelectrolyte multilayer membrane. KW - Zeolithe KW - Molecular Organic Frameworks KW - MOF KW - ZIF KW - Layer-by-Layer KW - Beschichtung KW - Polyelektrolyt PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-447729 DO - https://doi.org/10.1016/j.colcom.2017.11.004 SN - 2215-0382 VL - 22 SP - 14 EP - 17 PB - Elsevier B.V. CY - Amsterdam, NL AN - OPUS4-44772 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Pereira, P.M.R. A1 - Carvalho, José Joao A1 - Silva, S. A1 - Cavaleiro, J.A.S. A1 - Schneider, Rudolf A1 - Fernandes, R. A1 - Tomé, J.P.C. T1 - Porphyrin conjugated with serum albumins and monoclonal antibodies boosts efficiency in targeted destruction of human bladder cancer cells N2 - The synthesis of a novel PS conjugated with bovine and human serum albumin (BSA and HSA) and a monoclonal antibody anti-CD104 is reported, as well as their biological potential against the human bladder cancer cell line UM-UC-3. No photodynamic effect was detected when the non-conjugated porphyrin was used. Yet, when it was coupled covalently with the mAb anti-CD104, BSA and HSA, the resulting photosensitizer conjugates demonstrated high efficacy in destroying the cancer cells, the mAb anti-CD104 efficacy overruling the albumins. KW - Rinderserumalbumin KW - BSA KW - Monoklonale Antikörper KW - Blasenkrebs KW - Konjugate KW - Conjugates KW - Therapeutische Antikörper KW - CD104 PY - 2014 DO - https://doi.org/10.1039/c3ob42082e SN - 1477-0520 SN - 1477-0539 VL - 12 IS - 11 SP - 1804 EP - 1811 PB - RSC CY - Cambridge AN - OPUS4-30451 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schmidt, Stephan A1 - Hanelt, S. A1 - Canitz, C. A1 - Hoffmann, Holger A1 - Garbe, L.-A. A1 - Schneider, Rudolf T1 - Entwicklung monoklonaler Antikörper gegen Diclofenac N2 - Diclofenac (DCF) wird als nicht-steroidales, antientzündliches Arzneimittel gegen Fieber, Entzündungen, rheumatische Erkrankungen und Schmerzen eingesetzt. 70 % werden nach Einnahme wieder ausgeschieden. Aufgrund unvollständiger Elimination in den Kläranlagen lassen sich Rückstände im Trinkwasser und im Oberflächengewässer nachweisen. Diclofenac wird in der Umweltanalytik v.a. mittels GC-MS oder LCMS nachgewiesen. Bioanalytische Methoden machen sich die spezifische Antigen-Antikörper-Wechselwirkung zunutze, so z.B. Immunoassays. Die hierfür erforderlichen Antikörper werden durch Immunisierung mit einem Konjugat aus dem Analyten und einem Trägerprotein gewonnen. Die Kopplung kann direkt über die Carboxylfunktion von Diclofenac erfolgen. Um Abschirmungseffekte zu vermeiden, kann zwischen Protein und Analy1 ein Spacer sinnvoll sein. PY - 2015 SN - 1618-3258 SN - 1617-5301 IS - 4 SP - 107 EP - 109 PB - Wiley-VCH Verl. CY - Weinheim AN - OPUS4-35241 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Baldofski, Stefanie A1 - Hoffmann, Holger A1 - Lehmann, Andreas A1 - Breitfeld, Stefan A1 - Garbe, L.-A. A1 - Schneider, Rudolf T1 - Enzyme-linked immunosorbent assay (ELISA) for the anthropogenic marker isolithocholic acid in water N2 - Bile acids are promising chemical markers to assess the pollution of water samples with fecal material. This study describes the optimization and validation of a direct competitive enzyme-linked immunosorbent assay for the bile acid isolithocholic acid (ILA). The quantification range of the optimized Assay was between 0.09 and 15 mg/L. The assay was applied to environmental water samples. Most studies until now were focused on bile acid fractions in the particulate phase of water samples. In order to avoid tedious sample preparation, we undertook to evaluate the dynamics and significance of ILA levels in the aqueous phase. Very low concentrations in tap and surface water samples made a pre-concentration step necessary for this matrix as well as for wastewater treatment plant (WWTP) effluent. Mean recoveries for spiked water samples were between 97% and 109% for tap water and WWTP influent samples and between 102% and 136% for WWTP effluent samples. 90th percentiles of intra-plate and inter-plate coefficients of variation were below 10% for influents and below 20% for effluents and surface water. ILA concentrations were quantified in the range of 33-72 mg/L in influent, 21-49 ng/L in effluent and 18-48 ng/L in surface water samples. During wastewater Treatment the ILA levels were reduced by more than 99%. ILA concentrations of influents determined by ELISA and LC-MS/MS were in good agreement. However, findings in LC-ELISA experiments suggest that the true ILA levels in concentrated samples are lower due to interfering effects of matrix compounds and/or cross-reactants. Yet, the ELISA will be a valuable tool for the performance check and comparison of WWTPs and the localization of fecal matter input into surface waters. KW - ELISA KW - LC-MS/MS KW - Bile acids KW - Fecal marker KW - Surface water KW - Wastewater PY - 2016 DO - https://doi.org/10.1016/j.jenvman.2016.08.023 SN - 0301-4797 VL - 182 SP - 612 EP - 619 AN - OPUS4-37668 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Baldofski, Stefanie A1 - Canitz, C. A1 - Garbe, L.-A. A1 - Schneider, Rudolf T1 - Studies on the development of antibodies for the highly hydrophobic plasticizers DINCH and DEHT N2 - Diisononylcyclohexane-1,2-dicarboxylate (DINCH) and di-2-ethylhexyl terephthalate (DEHT), two of the most important substitutes for phthalate plasticizers, are used for a wide range of applications. Consequently, an increasing occurrence in urine and environmental samples is reported. Reliable and fast analytical methods for the quantification of these plasticizers are needed. So far, mainly GC-MS or LC-MS methods are used. We aimed to develop the first antibodies and immunoassays allowing for high-throughput analysis of samples. We designed two DINCH hapten structures and one DEHT hapten structure and employed hapten-protein conjugates for the immunization of rabbits. Sensitive competitive enzyme-linked immunosorbent assays (ELISAs) against each hapten using the produced polyclonal antibodies were established. Yet, binding of DINCH to the respective antibodies was not observed in neither direct nor indirect assay formats, even when using protein conjugates with the heterologous haptens and different carrier proteins in the indirect format. The use of surfactants and solvents in the sample buffer did not result in recognition of the plasticizers. Also, no binding of DEHT in ELISA employing the respective antibodies was detected. We speculate that the production of antibodies against these highly hydrophobic molecules is not possible via our route, however a different hapten design could overcome this obstacle. KW - Weichmacher KW - Phthalate KW - Antikörper KW - Selektivität KW - Ersatzstoffe KW - Polyclonal antibodies KW - Phthalate substitutes KW - Antibody production for hydrophobic molecules KW - DEHT KW - DINCH KW - Hapten design PY - 2018 DO - https://doi.org/10.1016/j.ab.2017.12.006 SN - 0003-2697 VL - 543 SP - 90 EP - 96 PB - Elsevier Inc. CY - Amsterdam, NL AN - OPUS4-44015 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schmidt, Stephan A1 - Hoffmann, Holger A1 - Garbe, L.-A. A1 - Schneider, Rudolf T1 - Liquid chromatography-tandem mass spectrometry detection of diclofenac and related compounds in water samples N2 - A frequently studied environmental contaminant is the active substance diclofenac, which is removed insufficiently in sewage treatment plants. Since its inclusion in the watch list of the EU Water Framework Directive, the concentrations in surface waters will be determined throughout Europe. For this, still, more precise analytical methods are needed. As a reference, HPLC-MS is frequently employed. One of the major metabolites is 4’-hydroxydiclofenac (4’-OH-DCF). Also, diclofenac lactam is important for assessing degradation and transformation. Aceclofenac (ACF), the glycolic acid ester of diclofenac is used as a drug, too, and could potentially be cleaved to yield diclofenac again. In various sewage treatment plant influent samples, diclofenac, 4’-OH-DCF, DCF lactam and ACF could be determined with detection limits of 3 µg/L, 0.2 µg/L, 0.17 µg/L and 10 ng/L, respectively. KW - Diclofenac KW - Festphasenextraktion KW - HPLC-MS KW - Probenvorbereitung KW - Kläranlage KW - Abwasser KW - Zyklisierung KW - Diclofenac KW - Solid-phase extraction KW - Sewage treatment plant KW - Cyclization KW - Sample treatment KW - HPLC–MS PY - 2018 DO - https://doi.org/10.1016/j.chroma.2018.01.037 SN - 0021-9673 SN - 1873-3778 VL - 1538 SP - 112 EP - 116 PB - Elsevier B.V. CY - Amsterdam, NL AN - OPUS4-44183 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schneider, Rudolf A1 - Almeida, Ângela A1 - Calisto, V. A1 - Esteves, V.I. A1 - Soares, A.M.V.M. A1 - Figueira, E. A1 - Freitas, R. T1 - Toxicity associated to uptake and depuration of carbamazepine in the clam Scrobicularia plana under a chronic exposure N2 - Carbamazepine (CBZ) is an antiepileptic drug commonly detected in aquatic systems, with toxic effects to inhabiting organisms. Limited information is known on stress response biomarkers associated to bioconcentration and depuration of CBZ in aquatic organisms. Moreover, few studies addressed if the response and recovery of organisms to a contaminant can change when they are collected in a contaminated site. This study intended to understand the bioconcentration and depuration of CBZ combined with its toxicological impact in Scrobicularia plana clams collected from two contrasting areas (MIRA, Mira channel, non-contaminated and LAR, Laranjo bay, arithropogenically impacted) from the Ria de Aveiro (Portugal). The clams were exposed for 14 days to environmentally relevant CBZ concentrations (0.0, 4.0 and 8.0 mu g/L), followed by a 14 day depuration period. CBZ concentrations in S. plana tissues were rapidly bioconcentrated during the exposure period. In the depuration period CBZ was eliminated, in some extent. The main toxic effects occurred at the highest concentration (8.0 mu g/L) after 14 days of exposure in which the clams from LAR accumulated ahigher CBZ concentration (LAR: similar to 10 ng/g FW) than clams from MIRA (MIRA: similar to 7 ng/g FW). LAR clams exhibited higher oxidative damage at this concentration, demonstrated by higher LPO levels over time (increase of similar to 1.4% relative to control) and, in comparison with MIRA clams (LAR: 17.7 nmol/g FW; MIRA: 11.4 nmol/g FW). After the depuration period, LAR clams recovered from the stress induced by CBZ. A decrease in LPO for LAR (decrease of similar to 40% in relation to the end of the exposure period) was accompanied by a decrease in CBZ tissue concentrations (decrease of similar to 61% relative to the end of the exposure period). MIRA clams were not oxidatively injured (low LPO levels remained unchanged after the depuration and CBZ decreased similar to 80% relative to the end of the exposure period). KW - Invertebrates KW - Pharmaceutical drugs KW - Biomarkers KW - Oxidative stress PY - 2017 DO - https://doi.org/10.1016/j.scitotenv.2016.12.069 SN - 0048-9697 VL - 580 SP - 1129 EP - 1145 AN - OPUS4-43297 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Schneider, Rudolf A1 - Schmidt, S. A1 - Hanelt, S. A1 - Canitz, C. A1 - Hoffmann, H. A1 - Garbe, L.-A. T1 - Synthetic Strategies for the Modification of Diclofenac N2 - For many heterogeneous sensor applications as well as the synthesis of hapten antigens to produce antibodies, protein conjugates of the target substance are essential. A requirement is that the target substance already offers or is modified to contain a functionality that allows for coupling to a protein, that is, an amino acid residue. Ideally, to avoid shielding of the compound by the carrier protein, a sufficient distance to the protein surface should be provided. With its carboxyl function diclofenac (DCF) allows for direct binding to lysine residues after in situ synthesis of the NHS ester. One problem is that diclofenac as free acid tends to autocondensation, which results in low yields. Here we describe the 'insertion' of a C6 spacer via synthesis of the amide with 6-aminohexanoic acid. To carry out the reaction in solution, first the methyl ester of the amino acid had to be produced. Due to otherwise low yields and large cleaning efforts, solid-phase synthesis on Fmoc Ahx Wang resin is recommended. The crude product is mainly contaminated by cleavage products from the resin which were removed by chromatography. The structure of the highly pure hapten was completely determined by nuclear magnetic resonance (NMR) spectroscopy. KW - Diclophenac KW - Hapten synthesis KW - Solid-phase synthesis PY - 2017 DO - https://doi.org/10.1055/s-0036-1588858 SN - 0936-5214 VL - 28 IS - 15 SP - 1984 EP - 1989 PB - Georg Thieme Verlag AN - OPUS4-43316 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Kuhne, Maren A1 - Dippong, Martin A1 - Flemig, Sabine A1 - Hoffmann, Katrin A1 - Petsch, K. A1 - Schenk, J.A. A1 - Kunte, Hans-Jörg A1 - Schneider, Rudolf T1 - Comparative characterization of mAb producing hapten-specific hybridoma cells by flow cytometric analysis and ELISA N2 - A novel method that optimizes the screening for antibody-secreting hapten-specific hybridoma cells by using flow cytometry is described. Cell clones specific for five different haptens were analyzed. We selectively double stained and analyzed fixed hybridoma cells with fluorophore-labeled haptens to demonstrate the target-selectivity, and with a fluorophore-labeled anti-mouse IgG antibody to characterize the level of surface expression of membrane-bound IgGs. ELISA measurements with the supernatants of the individual hybridoma clones revealed that antibodies from those cells, which showed the highest fluorescence intensities in the flow cytometric analysis, also displayed the highest affinities for the target antigens. The fluorescence intensity of antibody-producing cells corresponded well with the produced antibodies' affinities toward their respective antigens. Immunohistochemical staining verified the successful double labeling of the cells. Our method makes it possible to perform a high-throughput screening for hybridoma cells, which have both an adequate IgG production rate and a high target affinity. KW - Immunization KW - Hapten KW - Monoclonal antibodies KW - Hybridoma KW - Flow cytometry KW - ELISA KW - Estradiol KW - Estrone KW - Digoxigenin KW - Zearalenone KW - Aflatoxin KW - CLSM PY - 2014 DO - https://doi.org/10.1016/j.jim.2014.07.004 SN - 0022-1759 SN - 1872-7905 VL - 413 SP - 45 EP - 56 PB - Elsevier B.V. CY - Amsterdam AN - OPUS4-32322 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Almeida, Ângela A1 - Calisto, V. A1 - Esteves, V.I. A1 - Schneider, Rudolf A1 - Soares, A.M.V.M. A1 - Figueira, E. A1 - Freitas, R. T1 - Presence of the pharmaceutical drug carbamazepine in coastal systems: Effects on bivalves N2 - Carbamazepine (CBZ), an antiepileptic drug, is one of the most commonly detected pharmaceutical drugs in aquatic ecosystems, and is used as a marker of urban pollution. Since CBZ is designed to exert a biological effect, when it reaches aquatic environment high probability exist for toxic effects on non-target organisms. The present study evaluated the acute toxicity of environmentally relevant concentrations of CBZ (0.00, 0.03, 0.30, 3.00, 9.00 µg/L) in the edible clams Venerupis decussata (a native species) and Venerupis philippinarum (an invasive species) collected from the Ria de Aveiro. The effects on both species were assessed through the use of a battery of biomarkers mainly related with health status and oxidative stress. Furthermore, in this work an alternative and promising tool, the direct competitive immunoassay ELISA, for the direct CBZ quantification in clam's tissues, was applied. The results of the present work showed that CBZ in clam's tissues increased with the exposure concentration and V. decussata gave slightly higher values than V. philippinarum. Although the clams accumulated lower levels of CBZ than the concentration of exposure, these concentrations were enough to impair the health status and induce oxidative stress. However, a different response to CBZ was observed in the two species. While in V. philippinarum the lipid peroxidation levels increased at the highest CBZ concentration (9.00 µg/L), in V. decussata a significant decrease was seen. Moreover, glutathionse S-transferase activity was stimulated in V. decussata and decreased in V. philippinarum. Nevertheless, an induction of glutathione reductase, superoxide dismutase and cytochrome P450 3A4 activities was found in both species as a result of the exposure. The results indicate that, probably, V. philippinarum have a less efficient antioxidant system than V. decussata, and are therefore less capable to neutralize oxidative stress and consequently more sensitive to CBZ. The risk quotient determined for the Ria de Aveiro was higher than 1 indicating that a ecotoxicological risk is suspected. Furthermore, bioaccumulation of CBZ in clams should be taken into consideration since this chemical might be transferred along the food chain and affect non-target organisms. KW - Acute toxicity KW - Biomarkers KW - ELISA immunoassay KW - Pharmaceuticals KW - Clams KW - Carbamazepin KW - Toxikologie KW - Toxicology PY - 2014 DO - https://doi.org/10.1016/j.aquatox.2014.08.002 SN - 0166-445x SN - 1879-1514 VL - 156 SP - 74 EP - 87 PB - Elsevier CY - Amsterdam [u.a.] AN - OPUS4-31336 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Oberleitner, Lidia A1 - Garbe, L.-A. A1 - Dahmen-Levison, Ursula A1 - Schneider, Rudolf T1 - Improved strategies for selection and characterization of new monoclonal anticarbamazepine antibodies during the screening process using feces and fluorescence polarization immunoassay N2 - Immunoassays are suitable tools for high-throughput screenings. The prerequisite for accurate determinations by these methods is the selection of an excellent antibody. The production and selection of monoclonal antibodies is usually a tedious process. In this study, new strategies for improving antibody production and characterization were applied. This includes the monitoring of the immunization progress in mice through antibodies extracted from feces, which allows a time-resolved and animal-friendly monitoring of the immune response. Additionally, fluorescence polarization immunoassay (FPIA) could be successfully applied for fast and easy examination of cell culture supernatants and the investigation of antibody/antigen interactions including kinetics and fluorescence properties. These methods simplify the selection of the optimal antibody. As a target analyte, carbamazepine was chosen. This is a widely used antiepileptic drug which also frequently occurs in the environment. The new antibody enables CBZ determination in the concentration range 0.66–110 µg L-1 within 10 min using a high-throughput microtiter plate-based FPIA, and between 1.4 and 79 µg L-1 within 5 min applying an automated cuvette-based FPIA instrument, and from 0.05–36 µg L-1 using ELISA. The measurements were performed at a non-equilibrium state which improved the sensitivity and selectivity of the assays. Due to low cross-reactivity especially towards the main CBZ metabolite and other pharmaceuticals (<1%), this antibody gives the opportunity for application in medical and environmental analyses. KW - Antikörper KW - Emerging Pollutants KW - Schadstoffe KW - Monoklonal KW - Pharmazeutika KW - Arzneistoffe KW - Assay KW - Pesticide parathion-methyl KW - Waste-water KW - Samples KW - Pharmaceuticals KW - Quantification PY - 2016 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-392473 DO - https://doi.org/10.1039/c6ay01968d SN - 1759-9660 VL - 8 SP - 6883 EP - 6894 PB - Royal Society of Chemistry CY - London AN - OPUS4-39247 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Oberleitner, Lidia A1 - Dahmen-Levison, U. A1 - Garbe, L.-A. A1 - Schneider, Rudolf T1 - Application of fluorescence polarization immunoassay for determination of carbamazepine in wastewater N2 - Carbamazepine is an antiepileptic drug that can be used as a marker for the cleaning efficiency of wastewater treatment plants. Here, we present the optimization of a fast and easy on-site measurement system based on fluorescence polarization immunoassay and the successful application to wastewater. A new monoclonal highly specific anti-carbamazepine antibody was applied. The automated assay procedure takes 16 min and does not require sample preparation besides filtration. The recovery rates for carbamazepine in wastewater samples were between 60.8 and 104% with good intra- and inter-assay coefficients of variations (less than 15 and 10%, respectively). This automated assay enables for the onsite measurement of carbamazepine in wastewater treatment plants. KW - On-site measurement KW - Wastewater treatment plant KW - Fluorescence polarization immunoassay KW - Assay optimization KW - Mix-and-read assay PY - 2017 DO - https://doi.org/10.1016/j.jenvman.2017.01.063 SN - 0301-4797 SN - 1095-8630 VL - 193 SP - 92 EP - 97 PB - Elsevier Ltd. AN - OPUS4-39152 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Nitsche, Rudolf A1 - Müllereisert, F.A. T1 - Kennzeichen und Gütezeichen als Mittel der amtlichen Verwaltung der Werkstoffprüfung und -forschung; Prüfungszeugnisse PY - 1938 IS - 22 SP - 339 EP - 340 PB - Springer CY - Berlin AN - OPUS4-16950 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Lima, D.L.D. A1 - Schneider, Rudolf A1 - Scherer, H.W. A1 - Duarte, A.C. A1 - Santos, E.B.H. A1 - Esteves, V.I. T1 - Sorption-desorption behavior of atrazine on soils subjected to different organic long-term amendments N2 - Sorption of atrazine on soils subjected to three different organic amendments was measured using a batch equilibrium technique. A higher KF value (2.20 kg-1(mg L-1)-N) was obtained for soil fertilized with compost, which had a higher organic matter (OM) content. A correlation between the KFOC values and the percentage of aromatic carbon in OM was observed. The highest KFOC value was obtained for the soil with the highest aromatic content. Higher aromatic content results in higher hydrophobicity of OM, and hydrophobic interactions play a key role in binding of atrazine. On the other hand, the soil amended with farmyard manure had a higher content of carboxylic units, which could be responsible for hydrogen bonding between atrazine and OM. Dominance of hydrogen bonds compared to hydrophobic interactions can be responsible for the lower desorption capacity observed with the farmyard manure soil. The stronger hydrogen bonding can reduce the leaching of atrazine into drinking water resources and runoff to rivers and other surface waters. KW - Capillary electrophoresis KW - Atrazine KW - Sorption KW - Soil KW - Compost KW - Sewage sludge KW - Farmyard manure PY - 2010 DO - https://doi.org/10.1021/jf903937d SN - 0021-8561 SN - 1520-5118 VL - 58 IS - 5 SP - 3101 EP - 3106 PB - American Chemical Society CY - Columbus, Ohio AN - OPUS4-21108 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Oberleitner, Lidia A1 - Grandke, Julia A1 - Mallwitz, F. A1 - Resch-Genger, Ute A1 - Garbe, L.-A. A1 - Schneider, Rudolf T1 - Fluorescence polarization immunoassays for the quantification of caffeine in beverages N2 - Homogeneous fluorescence polarization immunoassays (FPIAs) were developed and compared for the determination of caffeine in beverages and cosmetics. FPIAs were performed in cuvettes in a spectrometer for kinetic FP measurements as well as in microtiter plates (MTPs) on a multimode reader. Both FPIAs showed measurement ranges in the µg/L range and were performed within 2 and 20 min, respectively. For the application on real samples, high coefficients of variations (CVs) were observed for the performance in MTPs; the CVs for FPIAs in cuvettes were below 4%. The correlations between this method and reference methods were satisfying. The sensitivity was sufficient for all tested samples including decaffeinated coffee without preconcentration steps. The FPIA in cuvettes allows a fast, precise, and automated quantitative analysis of caffeine in consumer products, whereas FPIAs in MTPs are suitable for semiquantitative high-throughput screenings. Moreover, specific quality criteria for heterogeneous assays were applied to homogeneous immunoassays. KW - caffeine KW - Decaffeinated coffee KW - Fluorescence polarization immunoassay KW - Homogeneous immunoassay KW - Quality assurance criteria PY - 2014 DO - https://doi.org/10.1021/jf4053226 SN - 0021-8561 SN - 1520-5118 VL - 62 IS - 11 SP - 2337 EP - 2343 PB - American Chemical Society CY - Columbus, Ohio AN - OPUS4-30613 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Grandke, Julia A1 - Oberleitner, Lidia A1 - Resch-Genger, Ute A1 - Garbe, L.-A. A1 - Schneider, Rudolf T1 - Quality assurance in immunoassay performance - carbamazepine immunoassay format evaluation and application on surface and waste water N2 - Carbamazepine (CBZ) is one of the most frequently detected pharmaceuticals in water samples. For the determination of this anthropogenic marker, various immunoassay formats were tested and evaluated in order to identify the most suitable one. For these direct competitive assays, the analyte was labelled with the enzyme horseradish peroxidase (HRP) or alkaline phosphatase (AP), and seven substrates with specific detection properties were used. The quality criteria for the standard curves were fulfilled by all HRP assays and the chemiluminescence AP format. Furthermore, intra- and inter-plate coefficients of variation as a measure of the achievable precision were determined for the samples. The application of the AP assays to surface water was unfeasible due to CBZ concentrations below the quantifiable concentration range. Surface as well as waste water samples could be analyzed with the HRP assays. Here, the HRP assay employing the chromogenic substrate 3,3',5,5'-tetramethylbenzidine yielded the best results. PY - 2013 DO - https://doi.org/10.1039/c3ay40702k SN - 1759-9660 SN - 1759-9679 VL - 5 IS - 15 SP - 3754 EP - 3760 PB - RSC Publ. CY - Cambridge AN - OPUS4-28860 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Grandke, Julia A1 - Oberleitner, Lidia A1 - Resch-Genger, Ute A1 - Garbe, L.-A. A1 - Schneider, Rudolf T1 - Quality assurance in immunoassay performance - comparison of different enzyme immunoassays for the determination of caffeine in consumer products N2 - Enzyme immunoassays with optical detection are amongst the most widely used bioanalytical tools. We defined seven parameters for the quality assessment of immunoassays that were addressed in a systematic study of direct and indirect immunoassays, using the enzymes horseradish peroxidase (HRP) and alkaline phosphatase (AP), the chromogenic substrates 3,3',5,5'-tetramethylbenzidine (TMB) and para-nitrophenyl phosphate, and the fluorescent substrates 3-(4-hydroxyphenyl)propionic acid and 4-methylumbelliferyl phosphate. The same monoclonal antibody against caffeine was used throughout the study. The four quality parameters regarding the standard curve were the test midpoint (sensitivity), the measurement range, the relative dynamic range of the signal, and the goodness of fit of the adjusted four-parameter logistic function. All HRP immunoassays showed a higher sensitivity compared to the AP assays. On the basis of all four criteria, it was established that the direct assay format is superior to the indirect format, the immunoassay using HRP TMB fulfilling all requirements best. In a second step, caffeine concentrations in 24 beverage and cosmetics samples were determined and three more quality parameters were assessed with this application. The direct HRP TMB assay showed one of the best intra- and inter-plate precisions and the best accuracy, defined by the correlation of results with those from the chosen reference method liquid chromatography tandem mass spectrometry (LC-MS/MS). Considering all criteria, HRP TMB seems to be the enzyme substrate system of choice preferably used in the direct assay format. KW - Enzyme immunoassay KW - Caffeine KW - Enzyme substrate KW - Competitive assay KW - Assay format KW - Direct KW - Indirect PY - 2013 DO - https://doi.org/10.1007/s00216-012-6596-0 SN - 1618-2642 SN - 1618-2650 VL - 405 IS - 5 SP - 1601 EP - 1611 PB - Springer CY - Berlin AN - OPUS4-27639 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Carvalho, José Joao A1 - Walter, Astrid A1 - Baermann, Yvonne A1 - Weller, Michael G. A1 - Panne, Ulrich A1 - Schenk, J.A. A1 - Schneider, Rudolf T1 - Non-invasive monitoring of immunization progress in mice via IgG from feces N2 - A non-invasive method to monitor the humoral immune response in mice after immunization is described. From fecal pellets of an individual mouse, a sufficient amount of active immunoglobulins or their fragments can be extracted to perform a regular examination of the status of the immune response by immunoassay. Hapten-specific antibodies from the feces of mice from three immunization trials showed very similar characteristics to those obtained from serum at a given date. Therefore, it can be suspected that some serum IgG enters the intestinal lumen and ends up in the feces, where they appear to be considerably stable. Hapten-specific IgAs were not found in the feces. Being able to analyze antibody titers in feces could be an interesting animal welfare refinement to standard practice that does not entail repeated blood sampling. KW - Immunization monitoring KW - IgG KW - Coproantibodies KW - Feces KW - Animal welfare KW - 3R concept PY - 2012 UR - http://iv.iiarjournals.org/content/26/1/63.full.pdf+html SN - 0258-851x VL - 26 IS - 1 SP - 63 EP - 70 PB - In vivo CY - Athens AN - OPUS4-25283 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gärtner, Stefanie A1 - Carvalho, J.J. A1 - Emmerling, Franziska A1 - Garbe, L.-A. A1 - Schneider, Rudolf T1 - Polyclonal murine and rabbit antibodies for the bile acid isolithocholic acid N2 - Bile acids are relevant markers for clinical research. This study reports the production of antibodies for isolithocholic acid, the isomer of the extensively studied lithocholic acid. The IgG titer and affinity maturation were monitored during the immunizations of three mice and two rabbits. In both animal models, polyclonal antibodies with a high selectivity and affinity were produced. The development of a direct competitive ELISA with a test midpoint of 0.69 ± 0.05 µg/L and a measurement range from 0.09–15 µg/L is reported. Additionally, the crystal structure of isolithocholic acid is described for the first time. KW - ELISA KW - Crystal structure KW - Competitive assay KW - Immunization monitoring KW - 3ß-hydroxy-5ß-cholanic acid PY - 2015 DO - https://doi.org/10.1080/15321819.2014.924419 SN - 1532-1819 SN - 1532-4230 VL - 36 IS - 3 SP - 233 EP - 252 PB - Taylor & Francis CY - Philadelphia, Pa. AN - OPUS4-31836 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Grandke, Julia A1 - Resch-Genger, Ute A1 - Bremser, Wolfram A1 - Garbe, L.-A. A1 - Schneider, Rudolf T1 - Quality assurance in immunoassay performance-temperature effects N2 - Temperature is one factor that influences the performance of immunoassays. Most commonly all incubation steps of the immunoassay are performed at ambient temperature. To systematically study the influence of temperature deviations on assay parameters like signal variation coefficients, limit of detection and measurement range, direct competitive enzyme immunoassays for the determination of two anthropogenic markers, caffeine and carbamazepine, were run at different temperatures above and below room temperature during individual assay steps. The temperature during the competition step had the greatest impact on the assay sensitivity yielding changes in test midpoints by a factor of 10 to 15. For carbamazepine, the test midpoints varied from 36 ng L-1, 108 ng L-1 to 378 ng L-1 employing 4 °C, 21 °C, or 37 °C as incubation temperature, respectively. The edge effect can be minimized resulting in a good plate homogeneity with small variation coefficients, when the assay is performed at ambient temperature. KW - Immunoassay KW - Temperature effects PY - 2012 DO - https://doi.org/10.1039/c2ay05918e SN - 1759-9660 SN - 1759-9679 IS - 4 SP - 901 EP - 905 PB - RSC Publ. CY - Cambridge AN - OPUS4-25740 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -