TY - JOUR A1 - Philipp, Rosemarie A1 - Schantz, M. A1 - Urquiza, M.P. A1 - Calderón, M. A. A. A1 - Torres, M.M. A1 - Carter, D. A1 - O'Connor, G. A1 - Sejeroe-Olsen, B. A1 - Ricci, M. A1 - Lalere, B. A1 - Peignaux, M. A1 - Kim, D.-H. A1 - Itoh, N. A1 - Wong, S.-K. A1 - Man, T.O. A1 - Caixeiro, J.M.R. T1 - CCQM-K50: Polycyclic aromatic hydrocarbons (PAHs) in soil/particulate matter PY - 2010 DO - https://doi.org/10.1088/0026-1394/47/1A/08006 SN - 0026-1394 SN - 1681-7575 VL - 47 SP - 08006-1 - 08006-47 PB - Inst. of Physics Publ. CY - Bristol AN - OPUS4-20821 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wang, L. A1 - Stebbings, R. A1 - Gaigalas, A.K. A1 - Sutherland, J. A1 - Kammel, M. A1 - John, M. A1 - Roemer, B. A1 - Kuhne, Maren A1 - Schneider, Rudolf A1 - Braun, M. A1 - Engel, A. A1 - Dikshit, D. A1 - Abbasi, F. A1 - Marti, G.E. A1 - Sassi, M. A1 - Revel, L. A1 - Kim, S.K. A1 - Baradez, M.-O. A1 - Lekishvili, T. A1 - Marshall, D. A1 - Whitby, L. A1 - Jing, W. A1 - Ost, V. A1 - Vonsky, M. A1 - Neukammer, J. T1 - Quantification of cells with specific phenotypes II: Determination of CD4 expression level on reconstituted lyophilized human PBMC labelled with anti-CD4 FITC antibody N2 - This report focuses on the characterization of CD4 expression level in terms of equivalent number of reference fluorophores (ERF). Twelve different flow cytometer platforms across sixteen laboratories were utilized in this study. As a first step the participants were asked to calibrate the fluorescein isothiocyanate (FITC) channel of each flow cytometer using commercially available calibration standard consisting of five populations of microspheres. Each population had an assigned value of equivalent fluorescein fluorophores (EFF denotes a special case of the generic term ERF with FITC as the reference fluorophore). The EFF values were assigned at the National Institute of Standards and Technology (NIST). A surface-labelled lyophilized cell preparation was provided by the National Institute of Biological Standards and Control (NIBSC), using human peripheral blood mononuclear cells (PBMC) pre-labeled with a FITC conjugated anti-CD4 monoclonal antibody. Three PBMC sample vials, provided to each participant, were used for the CD4 expression analysis. The PBMC are purported to have a fixed number of surface CD4 receptors. On the basis of the microsphere calibration, the EFF value of the PBMC samples was measured to characterize the population average CD4 expression level of the PBMC preparations. Both the results of data analysis performed by each participant and the results of centralized analysis of all participants' raw data are reported. Centralized analysis gave a mean EFF value of 22,300 and an uncertainty of 750, corresponding to 3.3% (level of confidence 68%) of the mean EFF value. The next step will entail the measurement of the ERF values of the lyophilized PBMC stained with labels for other fluorescence channels. The ultimate goal is to show that lyophilized PBMC is a suitable biological reference cell material for multicolor flow cytometry and that it can be used to present multicolor flow cytometry measurements in terms of ABC (antibodies bound per cell) units. KW - Surface labelled lyophilized PBMC KW - CD4 expression level KW - FITC KW - Equivalent fluorescein fluorophore (EFF) KW - Quantitative flow cytometry KW - Calibration KW - Standard measurement procedure KW - Measurement uncertainty KW - Reference cell material PY - 2015 DO - https://doi.org/10.1002/cyto.a.22634 SN - 0196-4763 SN - 1552-4922 SN - 1552-4930 VL - 87 IS - 3 SP - 254 EP - 261 PB - Wiley-Liss CY - Hoboken, NJ AN - OPUS4-32981 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Stebbings, R. A1 - Wang, L. A1 - Sutherland, J. A1 - Kammel, M. A1 - Gaigalas, A.K. A1 - John, M. A1 - Roemer, B. A1 - Kuhne, Maren A1 - Schneider, Rudolf A1 - Braun, M. A1 - Engel, A. A1 - Dikshit, D.K. A1 - Abbasi, F. A1 - Marti, G.E. A1 - Sassi, M.P. A1 - Revel, L. A1 - Kim, S.-K. A1 - Baradez, M.-O. A1 - Lekishvili, T. A1 - Marshall, D. A1 - Whitby, L. A1 - Jing, W. A1 - Ost, V. A1 - Vonsky, M. A1 - Neukammer, J. T1 - Quantification of cells with specific phenotypes I: Determination of CD4+ cell count per microliter in reconstituted lyophilized human PBMC prelabeled with anti-CD4 FICT antibody N2 - A surface-labeled lyophilized lymphocyte (sLL) preparation has been developed using human peripheral blood mononuclear cells prelabeled with a fluorescein isothiocyanate conjugated anti-CD4 monoclonal antibody. The sLL preparation is intended to be used as a reference material for CD4+ cell counting including the development of higher order reference measurement procedures and has been evaluated in the pilot study CCQM-P102. This study was conducted across 16 laboratories from eight countries to assess the ability of participants to quantify the CD4+ cell count of this reference material and to document cross-laboratory variability plus associated measurement uncertainties. Twelve different flow cytometer platforms were evaluated using a standard protocol that included calibration beads used to obtain quantitative measurements of CD4+ T cell counts. There was good overall cross-platform and counting method agreement with a grand mean of the laboratory calculated means of (301.7 ± 4.9) µL-1 CD4+ cells. Excluding outliers, greater than 90% of participant data agreed within ±15%. A major contribution to variation of sLL CD4+ cell counts was tube to tube variation of the calibration beads, amounting to an uncertainty of 3.6%. Variation due to preparative steps equated to an uncertainty of 2.6%. There was no reduction in variability when data files were centrally reanalyzed. Remaining variation was attributed to instrument specific differences. CD4+ cell counts obtained in CCQM-P102 are in excellent agreement and show the robustness of both the measurements and the data analysis and hence the suitability of sLL as a reference material for interlaboratory comparisons and external quality assessment. KW - CD4+ cell counting KW - Relative concentration measurement KW - Lyophilized cells KW - Flow cytometry KW - Standard measurement procedure KW - Measurement of uncertainty KW - Human immunodeficiency virus-1 KW - Acquired immunodeficiency syndrome KW - Reference material PY - 2015 DO - https://doi.org/10.1002/cyto.a.22614 SN - 0196-4763 SN - 1552-4922 SN - 1552-4930 VL - 87 IS - 3 SP - 244 EP - 253 PB - Wiley-Liss CY - Hoboken, NJ AN - OPUS4-32847 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Seto, J. A1 - Ma, Y. A1 - Davis, S.A. A1 - Meldrum, F. A1 - Gourrier, A. A1 - Kim, Y.-Y. A1 - Schilde, U. A1 - Sztucki, M. A1 - Burghammer, M. A1 - Maltsev, Sergey A1 - Jäger, Christian A1 - Cölfen, H. T1 - Structure-property relationships of a biological mesocrystal in the adult sea urchin spine N2 - Structuring over many length scales is a design strategy widely used in Nature to create materials with unique functional properties. We here present a comprehensive analysis of an adult sea urchin spine, and in revealing a complex, hierarchical structure, show how Nature fabricates a material which diffracts as a single crystal of calcite and yet fractures as a glassy material. Each spine comprises a highly oriented array of Mg-calcite nanocrystals in which amorphous regions and macromolecules are embedded. It is postulated that this mesocrystalline structure forms via the crystallization of a dense array of amorphous calcium carbonate (ACC) precursor particles. A residual surface layer of ACC and/or macromolecules remains around the nanoparticle units which creates the mesocrystal structure and contributes to the conchoidal fracture behavior. Nature’s demonstration of how crystallization of an amorphous precursor phase can create a crystalline material with remarkable properties therefore provides inspiration for a novel approach to the design and synthesis of synthetic composite materials. KW - Calcium carbonate biomineralization KW - Echinoderm skeleton KW - Hierarchical structuring KW - Mesocrystal KW - Skeletal elements PY - 2012 DO - https://doi.org/10.1073/pnas.1109243109 SN - 0027-8424 SN - 1091-6490 VL - 109 IS - 10 SP - 3699 EP - 3704 PB - National Academy of Sciences CY - Washington, DC AN - OPUS4-27726 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Villajos Collado, José Antonio A1 - Balderas‐Xicohténcatl, Rafael A1 - Al Shakhs, Ali N. A1 - Berenguer‐Murcia, Ángel A1 - Buckley, Craig E. A1 - Cazorla‐Amorós, Diego A1 - Charalambopoulou, Georgia A1 - Couturas, Fabrice A1 - Cuevas, Fermin A1 - Fairen‐Jimenez, David A1 - Heinselman, Karen N. A1 - Humphries, Terry D. A1 - Kaskel, Stefan A1 - Kim, Hyunlim A1 - Marco‐Lozar, Juan P. A1 - Oh, Hyunchul A1 - Parilla, Philip A. A1 - Paskevicius, Mark A1 - Senkovska, Irena A1 - Shulda, Sarah A1 - Silvestre‐Albero, Joaquin A1 - Steriotis, Theodore A1 - Tampaxis, Christos A1 - Hirscher, Michael A1 - Maiwald, Michael T1 - Establishing ZIF‐8 as a reference material for hydrogen cryoadsorption: An interlaboratory study N2 - AbstractHydrogen storage by cryoadsorption on porous materials has the advantages of low material cost, safety, fast kinetics, and high cyclic stability. The further development of this technology requires reliable data on the H2 uptake of the adsorbents, however, even for activated carbons the values between different laboratories show sometimes large discrepancies. So far no reference material for hydrogen cryoadsorption is available. The metal‐organic framework ZIF‐8 is an ideal material possessing high thermal, chemical, and mechanical stability that reduces degradation during handling and activation. Here, we distributed ZIF‐8 pellets synthesized by extrusion to 9 laboratories equipped with 15 different experimental setups including gravimetric and volumetric analyzers. The gravimetric H2 uptake of the pellets was measured at 77 K and up to 100 bar showing a high reproducibility between the different laboratories, with a small relative standard deviation of 3–4 % between pressures of 10–100 bar. The effect of operating variables like the amount of sample or analysis temperature was evaluated, remarking the calibration of devices and other correction procedures as the most significant deviation sources. Overall, the reproducible hydrogen cryoadsorption measurements indicate the robustness of the ZIF‐8 pellets, which we want to propose as a reference material. KW - Physical and theoretical chemistry KW - Atomic and molecular physics, and optics PY - 2024 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-594788 DO - https://doi.org/10.1002/cphc.202300794 SN - 1439-7641 SP - 1 EP - 7 PB - Wiley CY - Weinheim AN - OPUS4-59478 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Emteborg, H. A1 - Florian, D. A1 - Choquette, S. A1 - Ellison, S. L. R. A1 - Fernandes-Whaley, M. A1 - Mackay, L. A1 - McCarron, P. A1 - Panne, Ulrich A1 - Sander, S. G. A1 - Kim, S.-K. A1 - Held, A. A1 - Linsinger, T. A1 - Trapmann, S. T1 - Cooperation in publicly funded reference material production N2 - The meeting was organised by the European Commission’s Joint Research Centre and held at the JRC-Geel site on 22–23 February 2018. It was a follow-up of a similar meeting held in 2009. The objective of the meeting was to exchange information about ongoing publicly funded reference material (RM) production, identify areas of interest for future specific RMs, including certified reference material (CRM) developments, investigate potential areas of collaboration, and to identify areas which may be of a lower importance in the future for a specific RM producer. The benefit of exchanging such information is to avoid duplication of efforts in RM production, make better use of public funds by potentially matching competencies, and to address problems that are common to publicly funded RM producers. T2 - Meeting regarding cooperation in publicly funded reference material production, European Commission's Joint Research Centre CY - Geel, Belgium DA - 22.02.2018 KW - Public funding KW - Reference materials PY - 2018 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-470206 DO - https://doi.org/10.1007/s00769-018-1349-1 SN - 0949-1775 SN - 1432-0517 VL - 23 IS - 6 SP - 371 EP - 377 PB - Springer CY - Berlin AN - OPUS4-47020 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Anker, Andy S. A1 - Aspuru-Guzik, Alán A1 - Ben Mahmoud, Chiheb A1 - Bennett, Sophie A1 - Briling, Ksenia R. A1 - Changiarath, Arya A1 - Chong, Sanggyu A1 - Collins, Christopher M. A1 - Cooper, Andrew I. A1 - Crusius, Daniel A1 - Darmawan, Kevion K. A1 - Das, Basita A1 - David, Nicholas A1 - Day, Graeme M. A1 - Deringer, Volker L. A1 - Duarte, Fernanda A1 - Eardley-Brunt, Annabel A1 - Evans, Matthew L. A1 - Evans, Rob A1 - Fairlamb, Ian A1 - Franklin, Barnabas A. A1 - Frey, Jeremy A1 - Ganose, Alex M. A1 - Goulding, Mark A1 - Hafizi, Roohollah A1 - Hakkennes, Matthijs A1 - Hickey, Niamh A1 - James, Gillian A1 - Jelfs, Kim E. A1 - Kalikadien, Adarsh V. A1 - Kapil, Venkat A1 - Koczor-Benda, Zsuzsanna A1 - Krammer, Ferdinand A1 - Kulik, Heather J. A1 - Kumar, Vishank A1 - Kuttner, Christian A1 - Lam, Erwin A1 - Lou, Yuchen A1 - Mante, Eltjo A1 - Martin, Jennie A1 - Mroz, Austin M. A1 - Nematiaram, Tahereh A1 - Pare, Charles W. P. A1 - Patra, Sarbani A1 - Proudfoot, James A1 - Ruscic, Branko A1 - Ryder, Matthew R. A1 - Sakaushi, Ken A1 - Saßmannshausen, Jörg A1 - Savoie, Brett M. A1 - Schneider, Nadine A1 - Schwaller, Philippe A1 - Skjelstad, Bastian Bjerkem A1 - Sun, Wenhao A1 - Szczypiński, Filip T. A1 - Torrisi, Steven A1 - Ueltzen, Katharina A1 - Vishnoi, Shubham A1 - Walsh, Aron A1 - Wang, Xinwei A1 - Wilson, Chloe A1 - Wu, Ruiqi A1 - Zeitler, Jakob T1 - Discovering structure–property correlations: General discussion N2 - This article is a discussion of the paper "Web-BO: Towards increased accessibility of Bayesian optimisation (BO) for chemistry" by Austin M. Mroz, Piotr N. Toka, Ehecatl Antonio del Río Chanona and Kim E. Jelfs (Faraday discussions, 2025, 256, 221-234). KW - Materials design KW - Machine learning KW - Automation KW - Materials discovery PY - 2025 DO - https://doi.org/10.1039/d4fd90062f SN - 1359-6640 SN - 1364-5498 VL - 256 IS - Themed collection: Data-driven discovery in the chemical sciences SP - 373 EP - 412 PB - Royal Society of Chemistry (RSC) CY - Cambridge AN - OPUS4-62208 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Iqbal, S. A1 - Mady, A. H. A1 - Kim, Y.-I. A1 - Javed, U. A1 - Shafi, P. M. A1 - Nguyen, V. Q. A1 - Hussain, I. A1 - Tuma, Dirk A1 - Shim, J.-J. T1 - Self-templated hollow nanospheres of B-site engineered non-stoichiometric perovskite for supercapacitive energy storage via anion-intercalation mechanism N2 - The continual increase in energy demand and inconsistent supply have attracted attention towards sustainable energy storage/conversion devices, such as electrochemical capacitors with high energy densities and power densities. Perovskite oxides have received significant attention as anion-intercalation electrode materials for electrochemical capacitors. In this study, hollow nanospheres of nonstoichiometric cubic perovskite fluorides, KNi1-xCoxF3-delta (x = 0.2; delta = 0.33) (KNCF-0.2) have been synthesized using a localized Ostwald ripening. The electrochemical performance of the non-stoichiometric perovskite has been studied in an aqueous 3 M KOH electrolyte to categorically investigate the fluorine-vacancy-mediated charge storage capabilities. High capacities up to 198.55 mA h g-1 or 714.8 C g-1 (equivalent to 1435 F g-1) have been obtained through oxygen anion-intercalation mechanism (peroxide pathway, O-). The results have been validated using ICP (inductively coupled Plasma mass spectrometry) analysis and cyclic voltammetry. An asymmetric supercapacitor device has been fabricated by coupling KNCF-0.2 with activated carbon to deliver a high energy density of 40 W h kg-1 as well as excellent cycling stability of 98 % for 10,000 cycles. The special attributes of hollow-spherical, non-stoichiometric perovskite (KNCF-0.2) have exhibited immense promise for their usability as anion-intercalation type electrodes in supercapacitors. KW - Nanospheres KW - Perovskite KW - Supercapacitor PY - 2021 DO - https://doi.org/10.1016/j.jcis.2021.03.147 SN - 0021-9797 VL - 600 SP - 729 EP - 739 PB - Elsevier Inc. CY - Amsterdam AN - OPUS4-52873 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Tuma, Dirk A1 - Mady, A. H. A1 - Baynosa, M. L. A1 - Saad, M. A1 - Dhakal, G. A1 - Kim, W. K. A1 - Shim, Jae-Jin T1 - Morphology-engineered hollow NiTiO₃/C–Ag/Ag₃PO₄ S-scheme heterojunction photocatalyst: mechanistic insights into sunlight-driven tetracycline degradation N2 - Tetracycline (TCH), a widely used antibiotic, persists in aquatic and terrestrial environments, posing ecological risks and accelerating antibiotic resistance. To address this, we report a hollow-structured NiTiO₃/C–Ag/Ag₃PO₄ (NT/C–AAP) photocatalyst—the first hollow-type nickel titanate—synthesized via a self-template solvothermal route followed by photodeposition. The catalyst integrates key design strategies—hollow architecture, oxygen vacancies, carbon coating, and an S-scheme heterojunction—to optimize photocatalytic performance. The hollow structure enhances light harvesting via internal scattering, oxygen vacancies facilitate O2 adsorption and superoxide (O₂•⁻) generation, and the S-scheme heterojunction effectively suppresses electron–hole recombination while preserving strong redox potential. NT/C–AAP achieved 96% TCH degradation within 1 h and 82% mineralization in 3 h under solar light, far exceeding core–shell (18%) and aggregated (47%) NiTiO₃-based catalysts. Complete removal was realized within 40 min under 400 W visible light. The catalyst maintained 96% activity after five cycles, confirming excellent durability. Compared with previously reported NiTiO₃ photocatalysts, NT/C–AAP delivered a 50–400% performance enhancement arising from its engineered hollow structure and improved electronic properties. Mechanistic studies identified O₂•⁻ and •OH radicals as dominant species, validating the role of morphology and interface engineering in directing charge separation and redox activity. Additionally, a catalyst performance index was proposed to facilitate comparison across diverse conditions. Overall, this work introduces a novel, durable photocatalyst that links structural design to functional performance and demonstrates strong potential for practical environmental remediation. KW - Heterojunction photocatalyst KW - Photodegradation KW - Tetracycline PY - 2026 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-655946 DO - https://doi.org/10.1007/s42114-025-01600-x SN - 2522-0128 VL - 9 IS - 2 SP - 1 EP - 19 PB - Springer Nature CY - London AN - OPUS4-65594 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zeleny, R. A1 - Voorspoels, S. A1 - Ricci, M. A1 - Becker, Roland A1 - Jung, Christian A1 - Bremser, Wolfram A1 - Sittidech, M. A1 - Panyawathanakit, N. A1 - Wong, W. F. A1 - Choi, S.M. A1 - Lo, K.C. A1 - Yeung, W. Y. A1 - Kim, D.H. A1 - Han, J. A1 - Ryu, J. A1 - Mingwu, S. A1 - Chao, W. A1 - Schantz, M.M. A1 - Lippa, K.A. A1 - Matsuyama, S. T1 - Evaluation of the state-of-the-art measurement capabilities for selected PBDEs and decaBB in plastic by the international intercomparison CCQM-P114 N2 - An international intercomparison involving eight national metrology institutes (NMIs) was conducted to establish their current measurement capabilities for determining five selected congeners from the brominated flame retardant classes polybrominated diphenyl ethers and polybrominated biphenyls. A candidate reference material consisting of polypropylene fortified with technical mixtures of penta-, octa- and decabromo diphenyl ether and decabromo biphenyl, which was thoroughly assessed for material homogeneity and stability, was used as study material. The analytical procedures applied by the participants differed with regard to sample pre-treatment, extraction, clean-up, employed calibrants and type of calibration procedure as well as regarding analytical methods used for separation, identification and quantification of the flame retardant congeners (gas chromatography coupled to an electron capture detector (GC-ECD), gas chromatography-mass spectrometry in the electron ionisation mode (GC-EI-MS), gas chromatography-mass spectrometry in the electron capture negative ionisation mode (GC-ECNI-MS), and liquid chromatography-inductive coupled plasma-mass spectrometry (LC-ICP-MS)). The laboratory means agreed well with relative standard deviations of the mean of means of 1.9%, 4.8%, 5.5% and 5.4% for brominated diphenyl ether (BDE) 47, 183 and 209 and for the brominated biphenyl (BB) congener 209, respectively. For BDE 206, a relative standard deviation of 28.5% was obtained. For all five congeners, within-laboratory relative standard deviations of six measurements obtained under intermediate precision conditions were between 1% and 10%, and reported expanded measurements uncertainties typically ranged from 4% to 10% (8% to 14% for BDE 206). Furthermore, the results are in good agreement with those obtained in the characterization exercise for determining certified values for the flame retardant congeners in the same material. The results demonstrate the state-of-the-art measurement capabilities of NMIs for quantifying representative BDE congeners and BB 209 in a polymer. The outcome of this intercomparison (pilot study) in conjunction with possible improvements for employing exclusively calibrants with thoroughly assessed purity suggests that a key comparison aiming at underpinning calibration and measurement capability (CMC) claims of NMIs can be conducted. KW - Flame retardants KW - Polymer KW - Polybrominated diphenyl ethers (PBDEs) KW - Polybrominated biphenyls (PBBs) KW - International intercomparison PY - 2010 DO - https://doi.org/10.1007/s00216-009-3314-7 SN - 1618-2642 SN - 1618-2650 VL - 396 IS - 4 SP - 1501 EP - 1511 PB - Springer CY - Berlin AN - OPUS4-22905 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -