TY - CONF A1 - Schmidt, Stephan T1 - Entwicklung monoklonaler Antikörper gegen Diclofenac T2 - 2. Forum Junger Umweltwissenschaftler CY - Blomberg, Germany DA - 2015-06-22 PY - 2015 AN - OPUS4-33643 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Hantsche, Harald A1 - Schmidt, Dieter A1 - Kempf, Gerhard A1 - Treu, Dieter ED - Vetters, H. T1 - Fortschritte bei der Automatisierung der energiedispersiven Röntgenmikroanalyse T2 - 10. Sitzung d. Arbeitskreises Rastermikroskopie in der Materialprüfung, DVM-Tag CY - Dortmund, Germany DA - 13.10.1981 PY - 1982 SP - 21 EP - 28 CY - Berlin AN - OPUS4-36328 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schmidt, Martin A1 - Erdt, René A1 - Gödde, M. A1 - Salg, St. A1 - Ittemann, L. T1 - Selbstentzündungsverhalten von Feststoffen: Validierung der Extrapolation von Labortests mithilfe halbtechnischer Versuche bis 1 m3 N2 - Vorgestellt wird ein 2018 gestartetes Projekt zur Überprüfung der Extrapolation von im Labormaßstab ermittelten Selbstentzündungstemperaturen auf technisch relevante Volumina. Für die Ermittlung reaktionskinetischer Daten von Feststoffschüttungen stehen eine Reihe von Untersuchungsmethoden zur Verfügung. Dies sind thermische Analysen wie z. B. die differential scanning calorimetry DSC sowie Mikrokalorimetrie zur hochgenauen Messung von Wärmeströmen, bei denen sehr geringe Probenmengen zum Einsatz kommen. In der Regel wird das Selbstentzündungsverhalten jedoch mithilfe von isoperibolen oder adiabaten Warmlagerungsversuchen beurteilt, hier liegen die Probenvolumina üblicherweise im Bereich von ca. 100 cm3 bis zu einigen Litern. Die Extrapolation über mehrere Größenordnungen auf technische Volumina birgt Unsicherheiten, da mit Zunahme des Lagervolumens veränderte Start- und Randbedingungen vorliegen können. Zudem besteht die Möglichkeit, dass bei in technischen Lagern vorherrschenden niedrigen Temperaturen Reaktionen ablaufen, die in Standard- Laborversuchen nicht erfasst werden, aber einen wesentlichen Einfluss auf das Selbstentzündungsverhalten aufweisen können. Hauptziel des Projektes ist es daher, die im Labormaßstab vorhandenen Prüfeinrichtungen durch einen Versuchsstand zur Untersuchung von Probengrößen von bis zu 1000 dm3 zu erweitern, die Eignung (oder Nichteignung) der etablierten Methoden nachzuweisen und im Labormaßstab nicht erfassbare Einflussgrößen zu ermitteln. Zudem sollen anhand der kleinskaligen Tests Entscheidungskriterien abgeleitet werden, ob eine Extrapolation nach den derzeit üblichen Methoden zulässig ist. T2 - 15. BAM-PTB-Kolloquium zur chemischen und physikalischen Sicherheitstechnik CY - Brunswick, Germany DA - 21.05.2019 KW - Selbstentzündung KW - Formalkinetische Daten KW - Halbtechnische Versuche KW - Thermoanalytische Methoden PY - 2020 SN - 0030-834X VL - 130 IS - 1 SP - 9 EP - 18 AN - OPUS4-51285 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Lüth, Peter A1 - Uhlig, S. A1 - Frost, K. A1 - Malow, Marcus A1 - Michael-Schulz, Heike A1 - Schmidt, Martin A1 - Zakel, S. T1 - CEQAT-DGHS interlaboratory tests for chemical safety: Validation of laboratory test methods by determining the measurement uncertainty and probability of incorrect classification including so-called “Shark profiles” N2 - Laboratory test results are of vital importance for correctly classifying and labelling chemicals as “hazardous” as defined in the UN Globally Harmonized System (GHS) / EC CLP Regulation or as “dangerous goods” as defined in the UN Recommendations on the Transport of Dangerous Goods. Interlaboratory tests play a decisive role in assessing the reliability of laboratory test results. Interlaboratory tests performed over the last 10 years have examined different laboratory test methods. After analysing the results of these interlaboratory tests, the following conclusions can be drawn: 1. There is a need for improvement and validation for all laboratory test methods examined. 2. To avoid any discrepancy concerning the classification and labelling of chemicals, the use of validated laboratory test methods should be state of the art, with the results accompanied by the measurement uncertainty and (if applicable) the probability of incorrect classification. This paper addresses the probability of correct/incorrect classification (for example, as dangerous goods) on the basis of the measurement deviation obtained from interlaboratory tests performed by the Centre for quality assurance for testing of dangerous goods and hazardous substances (CEQAT-DGHS) to validate laboratory test methods. This paper outlines typical results (e.g. so-called “Shark profiles” – the probability of incorrect classification as a function of the true value estimated from interlaboratory test data) as well as general conclusions and steps to be taken to guarantee that laboratory test results are fit for purpose and of high quality. T2 - 13th International Symposium on Hazards, Prevention and Mitigation of Industrial Explosions (ISHPMIE 2020) CY - Braunschweig, Germany DA - 27.07.2020 KW - Dangerous goods KW - Hazardous substances KW - Interlaboratory test KW - Test method KW - Validation KW - Quality assurance KW - Measurement uncertainty KW - Incorrect classification KW - Shark profile PY - 2020 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-515376 UR - https://oar.ptb.de/files/download/5f3e662f4c93901010006dbf DO - https://doi.org/10.7795/810.20200724 VL - 2020 SP - 50 EP - 61 PB - Open Access Repository der Physikalisch-Technischen Bundesanstalt (PTB-OAR) CY - Braunschweig AN - OPUS4-51537 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wu, W. A1 - Wei, A. A1 - Huang, W. A1 - Zhao, Peng A1 - Schmidt, Martin A1 - Krause, Ulrich A1 - Wu, Dejian T1 - Experimental and theoretical study on the inhibition effect of CO2/N2 blends on the ignition behavior of carbonaceous dust clouds N2 - Gaseous inhibitors are used in many industries for the explosion prevention of combustible dusts, mitigating the potential hazard to humans, properties and environments. This work experimentally and theoretically studied the inerting effect of gaseous inhibitors on the ignition process of dust clouds in O2/N2/CO2 atmospheres, with an emphasis on the role of the CO2/N2 ratio. 10 different combustible carbonaceous dusts were selected, including grain dust, biomass dust and coal dust. Experimental results showed that the inhibition effect of CO2/N2 is closely related to the ignition mechanism of dust clouds. Specifically, a higher ratio of CO2/N2 yields a stronger inhibition effect on the ignition process of dust samples with relatively low volatile matter contents predominated by heterogeneous ignition. In addition, two novel steady-state ignition mechanism models were developed to interpret the experimental observations. Maxwell-Stefan equations were used to describe the diffusivity in the ternary O2/N2/CO2 gas mixtures. The analytical results were in good agreement with the experimental data of the minimum ignition temperature of dust cloud (MITC) in oxygen-lean atmospheres. The mechanism modelling can be used to estimate the critical ignition temperature of all carbonaceous dust clouds with a wide range of volatile matter content under different inert atmospheres, which will provide a reference for the explosion hazard assessment of dust posed by a hot surface in the process industries. KW - CO2/N2 ratio KW - Inerting effect KW - Volatile matter content KW - MITC KW - Mechanism model PY - 2021 DO - https://doi.org/10.1016/j.psep.2021.07.005 SN - 0957-5820 VL - 153 SP - 1 EP - 10 PB - Elsevier B.V. AN - OPUS4-53662 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wu, Dejian A1 - Tan, X. A1 - Wei, A. A1 - Duan, Q. A1 - Huang, W. A1 - Schmidt, Martin T1 - Ignition temperature and mechanism of carbonaceous dust clouds: The roles of volatile matter, CH4 addition, O2 mole fraction and diluent gas N2 - Minimum ignition temperature of dust clouds (MITC) was studied experimentally and theoretically in different atmospheres. Three carbonaceous dusts were tested in both air and O2/CO2 atmospheres with CH4 mole fraction from 0 to 2%. Results showed that the ignition risk of the three dusts significantly increases (decrease of MITC by ~100 ℃) with increasing XO2 from 21% to 50%, but significantly decreases replacing N2 in air with CO2. The inhibition effect of CO2 on MITCs could be diminished by increasing XO2 or adding CH4. The addition of small amount of CH4 has different effects on the MITCs of different dust samples, following the opposite order of volatile matter content: anthracite>bituminous coal>starch. Two modified steady-state ignition models, considering the density of mixture gas and dust cloud, XO2 and its diffusivity, were developed to interpret the experimental observations. The analysis revealed that the global heterogeneous ignition model suits well for the hybrid mixtures of anthracite or bituminous coal dusts. In contrast, the proposed global homogeneous ignition model was found to be only valid for the pure starch dust, and the extra CH4 addition could strongly affect the ignition process of starch, particularly in O2/CO2 atmospheres with higher XO2. KW - Dust explosions KW - Gas explosions KW - Minimum ignition temperature KW - Hybrid mixtures PY - 2021 DO - https://doi.org/10.1016/j.jhazmat.2020.124189 SN - 0304-3894 SN - 1873-3336 VL - 405 SP - 1 EP - 10 PB - Elsevier CY - Amsterdam AN - OPUS4-53838 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Zhao, P. A1 - Schmidt, Martin A1 - Krause, U. A1 - Duan, Q. A1 - Krietsch, Arne A1 - Wu, Dejian T1 - Experimental study on the minimum explosion concentration of anthracite dust: The roles of O2 mole fraction, inert gas and CH4 addition N2 - The explosion characteristics of anthracite coal dust with/without small amount of CH4 (1.14 vol %) were investigated by using a 20 L spherical explosion apparatus with an emphasis on the roles of oxygen mole fraction and inert gas. Two methods based on overpressure and combustion duration time were used to determine the minimum explosion concentration (MEC) or the lower explosion limit (LEL) of the pure anthracite coal dust and the hybrid coal-methane mixtures, respectively. The experiment results showed that increasing oxygen mole fraction increases the explosion risk of coal dust: with increasing oxygen mole fraction, the explosion pressure (Pex) and the rate of explosion pressure rise ((dp/dt)ex)) increase, while MEC decreases. The explosion risk of anthracite dust was found to be lower after replacing N2 with CO2, suggesting that CO2 has a better inhibition effect on explosion mainly due to its higher specific heat. However, the addition of 1.14% CH4 moderates the inhibition effect of CO2 and the promotion effect of O2 on anthracite dust explosion for some extent, increasing explosion severity and reducing the MEC of anthracite dust. For hybrid anthracite/CH4 mixture explosions, Barknecht’s curve was found to be more accurate and conservative than Chatelier’s line, but neither are sufficient from the safety considerations. The experimental results provide a certain help for the explosion prevention and suppression in carbonaceous dust industries. KW - Lower explosion limit KW - Minimun explosion concentration KW - Explosion charasteristics KW - Hybrid mixture KW - Explosion regimes PY - 2021 DO - https://doi.org/10.1016/j.jlp.2021.104490 VL - 2021 SP - 1 EP - 10 PB - Elsevier Ltd. ET - 71 AN - OPUS4-54074 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schmidt, Martin A1 - Erdt, René A1 - Gödde, M. A1 - Salg, St. T1 - Validierung der Extrapolation von Labortests mit Hilfe halbtechnischer Versuche bis 1 m3 und thermoanalytischer Methoden N2 - Zur Bestimmung der reaktionskinetischen Daten von Schüttgütern und iur Vorhersage des Selbstentzündungsverhaltens großer.Lager kommen verschiedene Analysemethoden zum Einsatz. Dabei handelt es sich .um thermische Verfahren wie die Differential-Scanning- Kalorimetrie OS(. die simultane Thermoanalyse STA sowie die Mikrokalorimetrie zur hochpräzisen Messung von Wärmeströmen. Für die oben genannten Methoden werden sehr kleine Probenmengen verwendet. In der Regel wird das Selbstentzündungsverhalten jedoch mit Hilfe von isoperibolen oder adiabatischen Warmlagerungsversuchen ermittelt: die Probenvolumina liegen hier meist im Bereich von ca. 100 cm3 bis zu mehreren Litern. Die Extrapolation auf technisch relevante Volumina birgt jedoch erhebliche Unsicherheiten. Diese Unsicherheiten zu identifizieren und zu reduzieren ist das Hauptziel eines 2018 gestarteten Forschungsprojekts. Dies soll in erster Linie durch den Aufbau eines Versuchsstandes zur Untersuchung von Probengrößen von bis zu. 1000 dm 3 geschehen. Sowohl Warmlagerungsversucl1e im Labormaßstab als auch thermoanalytische Verfahren. die mit Hilfe verschiedener Methoden ausgewertet werden. lassen, einzeln betrachtet. häufig nur bedingt zuverlässige Aussagen über das Selbstentzündungsverhalten von großen Schüttgütern zu. Es werden komplette Versuchsreihen mit allen genannten Prüfverfahren vorgestellt und Aussagen zur Anwendbarkeit der Extrapolationsmethoden diskutiert. T2 - VDI-Fachtagung "Sichere Handhabung brennbarer Stäube 2020" CY - Online meeting DA - 04.11.2020 KW - Selbstentzündung KW - Kinetische Daten KW - Halbtechnische Versuche KW - Thermoanalytische Methoden PY - 2020 SN - 978-3-18-092376-5 SP - 17 EP - 36 AN - OPUS4-52443 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Wu, Dejian A1 - Schmidt, Martin A1 - Huang, W. A1 - Wei, A. A1 - Krause, U. A1 - Wu, W. T1 - Inhibition effect of N2/CO2 blends on the minimum explosion concentration of agriculture and coal dusts N2 - Minimum explosion concentration (MEC) of three agriculture dusts and two coal dusts was studied via a 20-L explosion chamber to reveal the role of gaseous inhibitors. Both active method (CO2 diluting air) and passive method (CO2 replacing O2) were used. The TG and DTG thermal analysis tests were conducted to study the pyrolysis and combustion characteristics of dust samples. An alternative explosion criterion based on combustion duration time was used to determine MEC, and compared with the standardized overpressure method. Under 10-kJ ignition condition, as oxygen mole fraction (XO2) decreased from 21% to 10%, MEC of agriculture dusts and coal dusts respectively increased by around 5 times and 2 times. The active inerting method with a lower N2/CO2 ratio was found to have a better suppression effect on the explosion of the five carbonaceous dusts because the blend has a higher specific heat and a lower oxygen diffusion rate. KW - CO2/N2 ratio KW - Explosion criterion KW - Combustion kinetics KW - Inerting effect KW - Explosion characteristics PY - 2022 DO - https://doi.org/10.1016/j.powtec.2022.117195 SN - 0032-5910 VL - 399 SP - 1 EP - 12 PB - Elsevier B.V. AN - OPUS4-55013 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schmidt, Dirk A1 - Ruwe, L. T1 - Experimental study on the performance of the standardized test method for detonation flame arresters N2 - Flame arresters are autonomous protection systems and are among the constructive explosion protection measures that limit the effects of an explosion. In this study, the performance of the standardized test method regulated in the DIN EN ISO 16852 standard for in-line flame arresters for stable and unstable detonations, which is mainly designed for atmospheric conditions, is examined. In an interlaboratory comparison, experiments are performed for different pressures before ignition and explosion groups according to the standardized test method. The experimental data is analyzed in detail to further optimize the test method and to thus achieve an improved reproducibility of detonation tests at high pressures, especially regarding the deflagration to detonation transition. Based on these results, an improved test method for detonation flame arresters will be developed, which will ensure better reproducibility as well as applicability under non-atmospheric conditions. T2 - 28th ICDERS 2022 CY - Naples, Italy DA - 19.06.2022 KW - Flame arrester KW - Explosion protection KW - Experimental tests PY - 2022 AN - OPUS4-55101 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Gupta, P. A1 - Karnaushenko, D. D. A1 - Becker, C. A1 - Okur, I. E. A1 - Melzer, Michael A1 - Özer, B. A1 - Schmidt, O. G. A1 - Karnaushenko, D. T1 - Large Scale Exchange Coupled Metallic Multilayers by Roll-to-Roll (R2R) Process for Advanced Printed Magnetoelectronics N2 - Till now application of printed magnetoelectronics is hindered by lack of large area exchange coupled metallic multilayers required to produce printable magneto-sensory inks. Large-scale roll-to-roll (R2R) fabrication process is an attractive approach owing to its capabilities for high volume, high throughput, and large area manufacturing. Precise and high performance R2R sputtering technology is developed to fabricate large area giant magnetoresistive (GMR) thin-films stacks that contain 30 metallic bilayers prepared by continuous R2R sputtering of Co and Cu sequential on a hundred meters long polyethylene terephthalate (PET) web. The R2R sputtered Co/Cu multilayer on a 0.2 × 100 m2 PET web exhibits a GMR ratio of ≈40% achieving the largest area exchange coupled room temperature magneto-sensitive system demonstrated to date. The prepared GMR thin-film is converted to magnetosensitive ink that enables printing of magnetic sensors with high performance in a cost-efficient way, which promotes integration with printed electronics. An average GMR ratio of ≈18% is obtained for 370 printed magnetic sensors. The realized precise R2R sputtering approach can also be extended to a wide range of hybrid thin-film material systems opening up a path for new functional inks applied with printing technologies. KW - Printed Electronics KW - Flexible Magnetic Sensors KW - Roll-to-Roll Processing KW - Functional Materials KW - Upscaling PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-552344 DO - https://doi.org/10.1002/admt.202200190 SN - 2365-709X SP - 1 EP - 11 PB - Wiley-VCH CY - Weinheim, Deutschland AN - OPUS4-55234 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - JOUR A1 - Spallanzani, Roberta A1 - Koga, K. A1 - Cichy, S. A1 - Wiedenbeck, M. A1 - Schmidt, B. A1 - Oelze, Marcus A1 - Wilke, M. T1 - Lithium and boron difusivity and isotopic fractionation in hydrated rhyolitic melts N2 - Lithium and boron are trace components of magmas, released during exsolution of a gas phase during volcanic activity. In this study, we determine the difusivity and isotopic fractionation of Li and B in hydrous silicate melts. Two glasses were synthesized with the same rhyolitic composition (4.2 wt% water), having diferent Li and B contents; these were studied in difusion-couple experiments that were performed using an internally heated pressure vessel, operated at 300 MPa in the temperature range 700–1250 °C for durations from 0 s to 24 h. From this we determined activation energies for Li and B difusion of 57±4 kJ/mol and 152±15 kJ/mol with pre-exponential factors of 1.53 × 10–7 m2/s and 3.80× 10–8 m2 /s, respectively. Lithium isotopic fractionation during difusion gave β values between 0.15 and 0.20, whereas B showed no clear isotopic fractionation. Our Li difusivities and isotopic fractionation results difer somewhat from earlier published values, but overall confrm that Li difusivity increases with water content. Our results on B difusion show that similarly to Li, B mobility increases in the presence of water. By applying the Eyring relation, we confrm that B difusivity is limited by viscous fow in silicate melts. Our results on Li and B difusion present a new tool for understanding degassing-related processes, ofering a potential geospeedometer to measure volcanic ascent rates. KW - Hydrated silicate melts KW - Stable isotopes KW - Diffusion KW - Isotopic fractionation PY - 2022 UR - https://nbn-resolving.org/urn:nbn:de:kobv:b43-554496 DO - https://doi.org/10.1007/s00410-022-01937-2 VL - 177 IS - 8 SP - 1 EP - 17 PB - Springer AN - OPUS4-55449 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schmidt, Martin A1 - Gödde, M. A1 - Salg, S. A1 - Erdt, René T1 - Self-ignition Behaviour of Bulk Materials: How Reliable is the Extrapolation of Laboratory Tests? N2 - The self-ignition behaviour of bulks is usually determined with the aid of isoperibolic or adiabatic hot storage tests; the sample volumes here are typically in the range of approx. 100 cm³ to several litres. The extrapolation to technically relevant volumes holds, however, considerable uncertainties. To reduce these uncertainties, a test stand was set up that allows to investigation sample sizes of up to 1000 dm³. These allow the study of selfignition behavior closer to the conditions that prevail in practice. The suitability (or unsuitability) of the established methods (including dangerous goods classification tests) were to be demonstrated and influencing variables that cannot be measured on a laboratory scale were to be determined. In addition, various analytical methods were used for the determination of reaction kinetic data of solid bulk materials and to predict the self-ignition behaviour of large storages. These are thermal analyses such as differential scanning calorimetry DSC, simultaneous thermal analysis STA as well as microcalorimetry for highprecision measurement of heat flows. Complete test series using all mentioned test methods will be presented for crosslinked polyvinyl-pyrrolidone (PVP) and conclusions regarding the applicability of the extrapolation methods will be discussed. Hot storage tests up to semi-industrial scale and their combination with various thermoanalytical methods allow a much more precise prediction of the self-ignition behaviour of large bulks. A further promising approach to estimate their heat release rates, and hence, the risk of self-ignition under technical conditions, is the use of microcalorimetric methods. T2 - Loss Prevention 2022 CY - Prag, Czechia DA - 05.06.2022 KW - Self-ignition KW - Kinetic data KW - Semi-technical tests KW - Thermoanalytical methods PY - 2022 SN - 978-88-95608-88-4 DO - https://doi.org/10.3303/CET2290049 SN - 2283-9216 VL - 90 SP - 289 EP - 294 PB - AIDIC AN - OPUS4-55079 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schmidt, Martin A1 - Erdt, René A1 - Gödde, M. A1 - Salg, S. T1 - Self-ignition Behaviour of Bulk Materials: How Reliable is the Extrapolation of Laboratory Tests? N2 - The self-ignition behaviour of bulks is usually determined with the aid of isoperibolic or adiabatic hot storage tests; the sample volumes here are typically in the range of approx. 100 cm³ to several litres. The extrapolation to technically relevant volumes holds, however, considerable uncertainties. To reduce these uncertainties, a test stand was set up that allows to investigation sample sizes of up to 1000 dm³. These allow the study of selfignition behavior closer to the conditions that prevail in practice. The suitability (or unsuitability) of the established methods (including dangerous goods classification tests) were to be demonstrated and influencing variables that cannot be measured on a laboratory scale were to be determined. In addition, various analytical methods were used for the determination of reaction kinetic data of solid bulk materials and to predict the self-ignition behaviour of large storages. These are thermal analyses such as differential scanning calorimetry DSC, simultaneous thermal analysis STA as well as microcalorimetry for highprecision measurement of heat flows. Complete test series using all mentioned test methods will be presented for crosslinked polyvinyl-pyrrolidone (PVP) and conclusions regarding the applicability of the extrapolation methods will be discussed. Hot storage tests up to semi-industrial scale and their combination with various thermoanalytical methods allow a much more precise prediction of the self-ignition behaviour of large bulks. A further promising approach to estimate their heat release rates, and hence, the risk of self-ignition under technical conditions, is the use of microcalorimetric methods. T2 - Loss Prevention 2022 CY - Prague, Czech Republic DA - 05.06.2022 KW - Self-ignition KW - Kinetic data KW - Semi-technical tests KW - Thermoanalytical methods PY - 2022 AN - OPUS4-55080 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Wilrich, Cordula A1 - Schröder, Volkmar A1 - Brandes, E. A1 - Schmidt, Martin A1 - Wandrey, Peter-Andreas A1 - Mix, K.-H. A1 - Wehrstedt, Klaus-Dieter A1 - Bender, H. A1 - Stephan, U. A1 - Eberz, A. A1 - Steinbach, J. A1 - Stoessel, F. T1 - Plant and process safety - 2. Hazardous materials and process conditions N2 - "Ullmann's Encyclopedia of Industrial Chemistry" is the benchmark reference in chemistry and chemical and life science engineering, covering inorganic and organic chemicals, advanced materials, pharmaceuticals, polymers and plastics, metals and alloys, biotechnology and biotechnological products, food chemistry, process engineering and unit operations, analytical methods, environmental protection, and much more. The present article is part of the topic collection "Environmental Protection and Industrial Safety". It covers plant and process safety, focusing on hazardous materials and process conditions. KW - Flammable gases and vapors KW - Combustibility of liquids KW - Dust explosions KW - Explosive condensed substances KW - Harmful effects of substances KW - Exothermic and pressure-inducing chemical reactions PY - 2012 SN - 978-3-527-30673-2 DO - https://doi.org/10.1002/14356007.q20_q01 SP - 1 EP - 50 PB - Wiley-VCH CY - Weinheim AN - OPUS4-58108 LA - eng AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - CONF A1 - Schmidt, Martin T1 - Selbstentzündungsverhalten von Holz- und Biokohlen Gefahrguteinstufung sicher? N2 - Mit der Abkehr von der Nutzung fossiler Rohstoffe rücken regenerative Energieträger immer weiter in den Focus. Neben klassischen Holzkohlen werden verstärkt so genannte Biokohlen produziert. Dieser Begriff findet Verwendung für mit Hilfe verschiedener Verfahren karbonisierte pflanzliche, tierische oder mikrobielle Ausgangsstoffe. Diese Kohlen werden zum Teil über weite Strecken zum Bestimmungsort transportiert (Überseetransporte) oder vor Verwendung für längere Zeit gelagert. Häufig zeigen diese Kohlen ein kritisches Selbstentzündungsverhalten, wobei Einstufungstests (UN N.4 Test) versagen können. Ein negatives Testergebnis des UN N.4 Tests führte dabei in der Vergangenheit zur Nichteinstufung als selbsterhitzungsfähiger Stoff; in der Praxis entzündeten sich aber bereits vergleichsweise kleine Schüttungen (einige m³), z. B. beim Seetransport in Containern. Der Artikel geht auf dieses Problem ein, stellt Prüfverfahren vor und gibt Empfehlungen für sicheren Transport und Lagerung. T2 - VDI Fachtagung "Sichere Handhabung brennbarer Stäube CY - Nürnberg, Germany DA - 25.10.2023 KW - Biokohle KW - Selbstentzündung KW - Gefahrguteinstufung PY - 2023 AN - OPUS4-59597 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER - TY - GEN A1 - Schmidt, Martin T1 - Selbstentzündungsverhalten von Biokohlen - Gefahrguteinstufung immer sicher? N2 - Mit der Abkehr von der Nutzung fossiler Rohstoffe rücken regenerative Energieträger immer weiter in den Focus. Neben klassischen Holzkohlen werden verstärkt so genannte Biokohlen produziert. Dieser Begriff findet Verwendung für mit Hilfe verschiedener Verfahren karbonisierte pflanzliche, tierische oder mikrobielle Ausgangsstoffe. Diese Kohlen werden zum Teil über weite Strecken zum Bestimmungsort transportiert (Überseetransporte) oder vor Verwendung für längere Zeit gelagert. Häufig zeigen diese Kohlen ein kritisches Selbstentzündungsverhalten, wobei Einstufungstests (UN N.4 Test) versagen können. Ein negatives Testergebnis des UN N.4 Tests führte dabei in der Vergangenheit zur Nichteinstufung als selbsterhitzungsfähiger Stoff; in der Praxis entzündeten sich aber bereits vergleichsweise kleine Schüttungen (einige m³), z. B. beim Seetransport in Containern. Der Artikel geht auf dieses Problem ein, stellt Prüfverfahren vor und gibt Empfehlungen für sicheren Transport und Lagerung. KW - Biokohlen KW - Selbstentzündung KW - Gefahrguteinstufung PY - 2023 SN - 978-3-18-092424-3 SN - 978-3-18-092424-9 SN - 0083-5560 SP - 143 EP - 153 PB - VDI Verlag GmbH CY - Düsseldorf AN - OPUS4-59598 LA - deu AD - Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin, Germany ER -